ERREM
Scaffold Couplings
Cross coupling
Swivel coupling
Extension couplings + joining pins
Beam couplings
Page: 1 of 7
Page: 2 of 7
Page: 3 of 7
Cross coupling
Item number:
Weight:
Maximum load:
Safety factor:
Marking on cotter pin:
Cross coupling
EN 74:
21633:
C:
Corrosion protection
Sliding force
Fs
Fs
EN 74 class B
P-1057
1,5 kg
9,1 kN
1,65
EN74 C 21633
Coupling to join 2 pipes squarely
Tested in accordance with NEN-EN 74-1:2005
Product code
Manufacturing control through independent
certification institute
Thermal Galvanising
Breaking force
Fs
Ff
Ff
Pulling apart
Fp
Ff
a
Fp
Fs,c = 15 kN
Fs,c, = 9,1 kN (=1,65)
1 2 2 mm
Ff,c = 30 kN
Ff,c,= 18,2 kN ( = 1,65)
a
Fp
Fp = 30 kN
Fp, = 18,2 kN (= 1,65)
Rotation torque
MB
Steel pipe:
MB= 0,48 kNm = 1,65 c1= 15 kNm/rad
MB= 0,80 kNm = 1,00 c2= 6,0 kNm/rad
MT
MT= 130 Nm
MT
1 2
Aluminium pipe:
MB= 0,48 kNm = 1,65 c1 = 13 kNm/rad
MB= 0,80 kNm = 1,00 c2 = 5 kNm/rad
NB. When using couplings, specific interaction formulas in accordance with NEN-EN
12811 should be applied as a control measure.
Van Thiel United b.v.
L-01
Page: 4 of 7
Swivel coupling
Item number:
Weight:
Maximum load:
Safety factor:
Marking on cotter pin:
Swivel coupling:
EN 74:
21633:
C:
Corrosion protection
EN 74 class B
P-1126
1,7 kg
9,1 kN
1,65
EN74 C 21633
Coupling to join 2 pipes at an angle
Tested in accordance with NEN-EN 74-1:2005
Product code
Manufacturing control through independent
certification institute
Thermal Galvanising
Sliding force
Fs
Fs = 15 kN
Fs,= 9,1 kN
Breaking force
Fs
Fs
(=1,65) 1 2 2 mm
Ff
Ff
F
f
Ff = 20 kN
Ff,= 12,1 kN ( = 1,65)
Page: 5 of 7
Extension couplings
Item number:
Weight:
Maximum load:
Safety factor:
Marking on cotter pin:
Extension couplings:
EN 74:
21633:
C:
Corrosion protection
Sliding force
Fs
F1
Torque
Fs
l/4 l/4
l/2
l/2
l
Fs,c= 9 kN
Fs,c,= 5,45 kN ( = 1,65)
Page: 6 of 7
Beam Coupling
Item number:
Weight:
Maximum load:
Safety factor:
Marking on cotter pin:
Beam coupling
C:
Corrosion protection
P-1069
1,3 kg
36 kN per pair
1,65
EN74 C 41633
Coupling to attach pipes to steel beams
Manufacturing control through independent
certification institute
Sherardising
Pulling apart
Sliding force
F1
F1= 10 kN
F1,= 6,0 kN ( = 1,65 )