Beruflich Dokumente
Kultur Dokumente
Product name
Target readers
Product version
Edited by
Document version
Drafted by:
Date:
Reviewed by:
Date:
Reviewed by:
Date:
Approved by:
Date:
Confidentiality Level:
Internal Use Only
Revision Records
Date
2005-03-01
Revised version
Description
Author
Page 2 of 14
Confidentiality Level:
Internal Use Only
Contents
Chapter 1 Guide to OptiX 2500+Four-Fiber Multiplex Section Ring Deployment......................5
1.1 Topological Composition...................................................................................................... 5
1.1.1 Optical Fiber Composition......................................................................................... 5
1.1.2 Definition of Logic System.........................................................................................5
1.1.3 Service Transmission.................................................................................................6
1.2 Segment Switching and Ring Switching of the Four-Fiber Ring...........................................6
1.2.1 Differences and Identities between the Four-Fiber Ring and Two-Fiber Ring............6
1.3 Several Commands in the Four-Fiber Multiplex Section Ring that Should Be Noted...........9
1.3.1 Protocol Setting Command: apsc-set-protocol (newly added)...................................9
1.3.2 Protocol Query Command: apsc-get-protocol (newly added)....................................9
1.3.3 Segment Lock Command: apsc-start-locksw.............................................................9
1.3.4 Cancel the Segment Lock Command: apsc-stop-locksw...........................................9
1.3.5 Switching Start Command: apsc-set-switch (newly added).......................................9
1.3.6 Switching Clear Command: apsc-clr-switch (newly added).......................................9
1.3.7 Switching State Query Command: apsc-get-state4f (newly added).........................10
1.4 About the Version............................................................................................................... 10
1.5 Precautions to Networking................................................................................................. 10
1.5.1 Slot Requirements................................................................................................... 10
1.5.2 Definition Requirements of Logic System................................................................10
1.6 Configuration Examples..................................................................................................... 10
1.7 Fault Locating..................................................................................................................... 11
1.7.1 Analysis Method of Multiplex Section Protection Switching Event...........................12
1.7.2 Cross Page Analysis................................................................................................ 12
1.8 Appendix: 2500+ Backplane Bus Distribution Table...........................................................13
2005-03-01
Page 3 of 14
Confidentiality Level:
Internal Use Only
Keyword:
Guide to OptiX 2500+Four-Fiber Multiplex Section Ring Deployment
Summary:
Guide to OptiX 2500+Four-Fiber Multiplex Section Ring Deployment
Abbreviation list:
None.
Reference list:
None.
2005-03-01
Page 4 of 14
Confidentiality Level:
Internal Use Only
S1
1
P1
S2
P2
4
Page 5 of 14
Confidentiality Level:
Internal Use Only
Take Site 3 as an example, the definition of ADM site logic system of a 4-fiber
multiplex section ring is shown in Figure 2.
S1
1
P2 P1
S2
G2W
G1W
G2E
G1E
II. Differences
K1 and K2 bytes of APS protocols are transmitted through different fiber
channels.
There are 4 pairs of optical fibers in a 4-fiber multiplex section ring, therefore
K1 and K2 bytes are transmitted and received respectively in 4 directions.
However, the protocols are processed only according to the K1 and K2 bytes
received by the protection channel fibers in the 4-fiber multiplex section. The
following shows a protection switching event of a multiplex section:
APS EVENT
2005-03-01
Page 6 of 14
Confidentiality Level:
Internal Use Only
ID
sys1
EVENT-NO
TIMESTAMP
11
EVENT
SF_DET
PARAS TIME
0x0000 2001-1-4 4:33:8 0x77735d15
12
sys1
13
//request
K_SENDS
K_DIR
0x0000 2001-1-4
4:33:8
0x77735dcf
//Transmit the ring switching request due to signal failure via G2W short path to
the site with the multiplex section node number as 3.
sys1
14
K_SENDS
sys1
15
K_DIR
//Transmit the ring switching request due to signal failure via G2E long path to
the site with the multiplex section node number as 3.
sys1
16
STATE_TRAN
17
K_RECV
sys1
18
K_DIR
//G2E receives the ring switching request due to signal failure transmitted from
Site 3 via the long path.
sys1
19
XC_EXECUTE
//Send the ring switching page to the XC board and complete protection
switching.
The above event shows that K1 and K2 bytes bearing the protocols are only
sent to the fibers of the protection channel, and the protection switching is
implemented only based on the K1 and K2 bytes received by the protection
channel..
The primary difference between the 4-fiber ring and 2-fiber ring and the most
significant advantage of the 4-fiber ring is segment switching. In a 2-fiber
multiplex section, one fiber is used to transmit both working services and
protection services, therefore fiber cut in any section will cause switching of the
entire ring, leading to instant service interruption of the entire ring. In addition, if
multiple fiber cuts occur on the entire ring, interruption of part or all of the
services will result.
However, segment switching in the 4-fiber ring improves the reliability greatly.
In the 4-fiber multiplex section ring, if only the fibers of the working channel are
damaged, then switching only happens between the two adjacent sites, and
this is so called segment switching. At this time, the services are switched
from the working channel fibers to the protection channel fibers of this
segment, thus only the services between the two adjacent sites are interrupted,
while the services of other segments are not affected. Moreover, damages of
2005-03-01
Page 7 of 14
Confidentiality Level:
Internal Use Only
multiple working channel fibers will not cause service interruption, therefore the
reliability of the 4-fiber multiplex section ring is greatly improved.
As shown in Figure 3, if only the working channel fibers S1 and S2 between
Site 1 and Site 2 are broken (no matter whether one or both of them are
broken), while the protection channel fibers P1 and P2 are in good condition,
the services originally transmitted on the fibers S1 and S2 between Site 1 and
Site 2 will be switched to the fibers P1 and P2 for transmission, while the
services of other segments are still transmitted on S1 and S2, and the extra
services of other segments are not affected either.
S1
1
P1
S2
P2
4
S1
1
P1
S2
P2
4
2005-03-01
Page 8 of 14
Confidentiality Level:
Internal Use Only
Page 9 of 14
Confidentiality Level:
Internal Use Only
Page 10 of 14
Confidentiality Level:
Internal Use Only
Configuration files:
:login:1,"nesoft"
//Log in NE
:cfg-init<sysall>
:cfg-create-board:1,pq1:5&6&9&10,s16:7,xcs
//Create boards
Page 11 of 14
Confidentiality Level:
Internal Use Only
:ptp:bid,fa,4,10,1,0;
This command is used to query the current working page of the XC board. If
protection switching occurs, the queried result shows the cross page after
switching.
:ptp:bid,12,97,1;
2005-03-01
Page 12 of 14
Confidentiality Level:
Internal Use Only
This command is used to query the mutual protection relations between the
buses after protection switching of the XC board.
For the use of the above commands and analysis of the queried results, refer
to the related information about board PTP commands, XC board bus and its
limitations, etc. No more description here.
The following shows the queried data results of 2500+ a 2-fiber multiplex
section protection switching ring in the normal state and the westward
switching state:
Normal page
ff ff ff ff 70 ff ff ff 71 ff ff ff ff ff ff ff
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
14
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
60 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
1ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
61 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
04 08 ff ff ff ff ff ff ff ff ff ff ff ff ff ff
cross connection
30 50 ff ff ff ff ff ff ff ff ff ff ff ff ff ff
cross connection
:ptp:7,fa,4,10,1,0;
ff ff ff ff 70 ff ff ff 71 ff ff ff ff ff ff ff
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
60 ff ff ff ff ff ff ff 61 ff ff ff ff ff ff ff
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff
04 08 ff ff ff ff ff ff ff ff ff ff ff ff ff ff
30 38 ff ff ff ff ff ff ff ff ff ff ff ff ff ff
:ptp:7,12,97;
cmd 0: 07 12 97 01 10 b0 98 b1 99 b2 9a b3 9b b4 9c b5 9d b6
9e b7 9f 50 38 51 39 52 3a 53 3b 54 3c 55 3d 56 3e 57 3f
The bus protection data are divided into two groups, the red ones indicate the
bus numbers of the outgoing cross connection, while the blue ones indicate
those of the incoming cross connection. To distinguish the incoming and
outgoing buses, add 60 to the corresponding incoming bus numbers for all the
outgoing bus numbers. Each two numbers form a group, the bus indicated by
the latter number protects the bus indicated by the former number .The above
data can be translated as that 0x38 of the outgoing bus protects 0x50, 0x39
protects 0x51, and so on so forth, while 0x38 of the incoming bus protects
0x50, and so on so forth. This exactly reflects the protection relation of the
buses, that is, when westward (fiber cut of the optical board in Slot 9)
protection switching occurs, the eastward (Slot 10) line bus protects the
westward (Slot 9) line bus.
Bus No.
#0c~0f
#08~0b
Huawei Confidential. No disclosure without permission.
Page 13 of 14
2005-03-01
Confidentiality Level:
Internal Use Only
#04~07
#00~03(SQ1/SL4) #00~07(SD4) #00~0f(S16)
#20~2f
#40~4f
#50~5f
#30~3f
#10~13(SQ1/SL4) #10~17(SD4) #10~1f(S16)
#14~17
#18~1b
#1c~1f
Page 14 of 14