Sie sind auf Seite 1von 83

PT.

DALUT NUSANTARA BARU


Inspection Services, Technical Testing & Supplier

THICKNESS MEASUREMENT REPORT


GENERAL PARTICULARS

Ship Name

TB. ADAM TUG 3

Owner

PT. EKA NUSA BAHARI

IMO No

9611204

Register No

16533

Class Society

Biro Klasifikasi Indonesia

Class Id No.

16533

Port Registry

TANJUNG PRIOK

Ship Type

Tug Boat

Year built

Lama

Name of company performing


thickness measurement

PT. DALUT NUSANTARA BARU

Thickness measurement
company certified by

Biro Klasifikasi Indonesia

Certificate No

58. 15. SB2116

Certificate Valid From

September 8, 2015

Place of measurement

PT. BEN SANTOSA , KAMAL


INDONESIA

First date measurement


Last date measurement

:
:

14 December, 2016
15 Oktober, 2016

Survey

Intermediate Survey

Detail of equipment used

ATG II / Serial No. 14 - 1986

Qualification of operator

Ultrasonic Testing (UT) - Level II

to :

September 8, 2020

Report Number

Name of Operator
Signature
Official stamp

: Purwo Agung A.
:
:

451 / DNB / TEK / UTG / XII / 2016

Name of Surveyor :

Consisting of : 51 sheets

Hendra Bagus Kurniawa

Signature
:
Classification Society : Biro Klasifikasi Indonesia
Official Stamp
:

PT. DALUT NUSANTARA BARU


Inspection Services, Technical Testing & Supplier

SHIP NAME :
Class ID
:

TB. ADAM TUG 3


16533

TABLE OF CONTENTS
Certificate of Approval
Table of contents
General Particulars
General Arrangement
Shell Expansion
*Drawing
*Table
Kort Nozzle
*Drawing
*Table
Skeg
*Drawing
*Table
Rudder Blade
*Drawing
*Table

Page

I.1
I.2 - I.5
II.1
II.2
III.1
III.2
IV.1
IV.2

REPORT OF THICKNESS MEASUREMENT ON ALL DECK PLATING


( ALL BOTTOM SHELL PLATING or SIDE SHELL PLATING )*
Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

STRAKE
POSITION
PLATE
POSITION
12th Fwd
11th
10th
9th
8th
7th
6th
5th
4th
3rd
2nd
1st
Amidships
1st
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
11th
12th Aft
Operator's Signature :

451 / DNB / TEK / UTG / XII / 2016

16533

STRAKE K - BOTTOM PLATING


No.
or
Letter

Original
Thk
(mm)

13 - 35
13 - 35
-3 - 13

12
12
12

11.8
11.9
12.0

Gauged
p

12.0

FORWARD READING
Diminution S
mm
%

0.2
0.1
0.0

1.67
0.83
0.00

Surveyor's Signature :

Diminution P
mm
%

0.0

0.00

Gauged
S

11.8
11.8

11.9

AFT READING
Diminution S
mm
%

0.2
0.2

1.67
1.67

Diminution P
mm
%

0.1

0.83

Mean Diminution
%
S

0.83
1.25
0.83
0.00
0.00
0.00

Remarks:
N = 'Replate area
S = Suspect area (75% - 100% of corrosion lim
R = Wasted area (beyond corrosion limit)

Purwo Agung A.

Hendra Bagus Kurniawa

Printed in BOLD and BLACK consider renewed plate

PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

REPORT OF THICKNESS MEASUREMENT ON ALL DECK PLATING


( ALL BOTTOM SHELL PLATING or SIDE SHELL PLATING )*
Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

STRAKE
POSITION
PLATE
POSITION
12th Fwd
11th
10th
9th
8th
7th
6th
5th
4th
3rd
2nd
1st
Amidships
1st
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
11th
12th Aft
Operator's Signature :

451 / DNB / TEK / UTG / XII / 2016

16533

STRAKE A - BOTTOM PLATING


No.
or
Letter

Original
Thk
(mm)

33 - 38
33 - 37
30 - 33
14 - 30
14 - 30
6 - 14
-3 - 6
-3 - 6

10
10
10
10
10
10
10
12

Gauged
S

9.0
8.9
8.9
8.9
8.9
8.9
8.9

9.0
9.0
8.8
8.8
8.9
8.4

FORWARD READING
Diminution S
mm
%

1.0
1.1
1.1
1.1
1.1
1.1
1.1

10.00
11.00
11.00
11.00
11.00
11.00
11.00

12.0

Surveyor's Signature :

Diminution P
mm
%

1.0
1.0
1.2
1.2
1.1
1.6

10.00
10.00
12.00
12.00
11.00
16.00

0.0

0.00

Gauged

AFT READING
Diminution S
mm
%

Diminution P
mm
%

9.0
8.9
8.9

9.0
8.9
8.9

1.0
1.1
1.1

10.00
11.00
11.00

1.0
1.1
1.1

10.00
11.00
11.00

8.9
8.9
8.9

8.4
8.9

1.1
1.1
1.1

11.00
11.00
11.00

1.6
1.1

16.00
11.00

0.0

0.00

12.0

Remarks:
N = 'Replate area

Mean Diminution
%
S

11.00
11.00
5.50
11.00
11.00
11.00
0.00

S = Suspect area (75% - 100% of corrosion lim


R = Wasted area (beyond corrosion limit)

Purwo Agung A.

Hendra Bagus Kurniawa

Printed in BOLD and BLACK consider renewed plate

PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

REPORT OF THICKNESS MEASUREMENT ON ALL DECK PLATING


( ALL BOTTOM SHELL PLATING or SIDE SHELL PLATING )*
Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

STRAKE
POSITION
PLATE
POSITION
12th Fwd
11th
10th
9th
8th
7th
6th
5th
4th
3rd
2nd
1st
Amidships
1st
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
11th
12th Aft
Operator's Signature :

451 / DNB / TEK / UTG / XII / 2016

16533

STRAKE B - BOTTOM PLATING


No.
or
Letter

Original
Thk
(mm)

32 - 39
26 - 32
18 - 26
16 - 18
-3 - 16
-3 - 16

10
10
10
10
10
10

Gauged
S

8.8
8.9
8.8
10.0
8.8

8.7
8.8
8.8
10.0
8.8

FORWARD READING
Diminution S
mm
%

1.2
1.1
1.2
0.0
1.2

12.00
11.00
12.00
0.00 N
12.00

Surveyor's Signature :

Diminution P
mm
%

Gauged

N
1.2

12.00

8.8
8.7
8.9
10.0
8.9
8.8

8.8
8.9
8.7
10.0
8.9
8.8

AFT READING
Diminution S
mm
%

Diminution P
mm
%

1.2
1.3
1.1
0.0
1.1
1.2

1.2
1.1
1.3
0.0
1.1
1.2

12.00
13.00
11.00
0.00 N
11.00
12.00

12.00
11.00
13.00
0.00
11.00
12.00

Mean Diminution
%
S

0.00
11.50
6.00

Remarks:
N = 'Replate area
S = Suspect area (75% - 100% of corrosion lim
R = Wasted area (beyond corrosion limit)

Purwo Agung A.

Hendra Bagus Kurniawa

Printed in BOLD and BLACK consider renewed plate

PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

REPORT OF THICKNESS MEASUREMENT ON ALL DECK PLATING


( ALL BOTTOM SHELL PLATING or SIDE SHELL PLATING )*
Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

STRAKE
POSITION
PLATE
POSITION
12th Fwd
11th
10th
9th
8th
7th
6th
5th
4th
3rd
2nd
1st
Amidships
1st
2nd
3rd
4th
5th
6th
7th
8th
9th
10th
11th
12th Aft
Operator's Signature :

451 / DNB / TEK / UTG / XII / 2016

16533

STRAKE C - BOTTOM PLATING


No.
or
Letter

Original
Thk
(mm)

22 - 36
22 - 36
22 - 36
22 - 36
5 - 22
5 - 22
-3 - 5

10
10
10
10
10
10
10

Gauged

FORWARD READING
Diminution S
mm
%

8.9
8.9
8.8
8.8
8.7

8.9
8.8
8.9
8.9
8.7

1.1
1.1
1.2
1.2
1.3

11.00
11.00
12.00
12.00
13.00

8.8

8.8

1.2

12.00

Surveyor's Signature :

Diminution P
mm
%

1.1
1.2
1.1
1.1
1.3

11.00
12.00
11.00
11.00
13.00

Gauged

AFT READING
Diminution S
mm
%

Diminution P
mm
%

9.0

9.0

1.0

10.00

1.0

10.00

8.9
8.8
8.9
8.9

8.9
8.8
8.8
8.9

1.1
1.2
1.1
1.1

11.00
12.00
11.00
11.00

1.1
1.2
1.2
1.1

11.00
12.00
12.00
11.00

Mean Diminution
%
S

5.50
10.50
6.00
11.50
12.50
5.50
11.50

Remarks:
S = Suspect area (75% - 100% of corrosion lim
R = Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

MEASUREMENT ON ALL DECK PLATING


L PLATING or SIDE SHELL PLATING )*

451 / DNB / TEK / UTG / XII / 2016

STRAKE K - BOTTOM PLATING


Mean Diminution
%
P

Max. Allowable
Diminution
mm
%

0.00
0.00
0.42
0.00
0.00
0.00

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

2.4
2.4
2.4
0.0
0.0
0.0

20%
20%
20%
20%
20%
20%

Printed in BOLD and BLACK consider renewed plate.

pection services, Technical Testing & Supplier - Indonesia

Page : I.2

TM1

MEASUREMENT ON ALL DECK PLATING


L PLATING or SIDE SHELL PLATING )*

451 / DNB / TEK / UTG / XII / 2016

STRAKE A - BOTTOM PLATING


Mean Diminution
%
P

10.50
11.50
6.00
13.50
13.50
0.00
0.00

Max. Allowable
Diminution
mm
%

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.4

20%
20%
20%
20%
20%
20%
20%
20%

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)
Printed in BOLD and BLACK consider renewed plate.

pection services, Technical Testing & Supplier - Indonesia

Page : I.3

TM1

MEASUREMENT ON ALL DECK PLATING


L PLATING or SIDE SHELL PLATING )*

451 / DNB / TEK / UTG / XII / 2016

STRAKE B - BOTTOM PLATING


Mean Diminution
%
P

Max. Allowable
Diminution
mm
%

0.00
11.50
6.00

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

2.0
2.0
2.0
2.0
2.0
2.0

20%
20%
20%
20%
20%
20%

Printed in BOLD and BLACK consider renewed plate.

pection services, Technical Testing & Supplier - Indonesia

Page : I.4

TM1

MEASUREMENT ON ALL DECK PLATING


L PLATING or SIDE SHELL PLATING )*

451 / DNB / TEK / UTG / XII / 2016

STRAKE C - BOTTOM PLATING


Mean Diminution
%
P

Max. Allowable
Diminution
mm
%

5.50
11.00
5.50
11.00
12.50
6.00
5.50

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

2.0
2.0
2.0
2.0
2.0
2.0
2.0

20%
20%
20%
20%
20%
20%
20%

Printed in BOLD and BLACK consider renewed plate.

TM1

pection services, Technical Testing & Supplier - Indonesia

Page : I.5

REPORT OF THICKNESS MEASUREMENT ON SHELL AND DECK PLATING


( one,two or three transverse section dependant on vessel age )
Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

451 / DNB / TEK / UTG / X

16533

STRENGTH DECK PLATING


1st TRANSVERSE SECTION AT FRAME
NUMBER : 16 - 17

STRAKE
POSITION

No.
or

Org.

1st strake inboard

Diminution
S

Diminution
P

mm

Diminution

2nd TRANSVERSE SECTION AT FRAME


NUMBER : 17 - 18
No.
or

Org.

Gauged

Diminution
S

Diminution
P

mm

Diminution

3rd TRANSVERSE SECTIO


NUMBER :20-21
No.
or

Org.

Gauged

Diminut
S

mm

mm

mm

mm

mm

12

11.8

11.8

0.2

1.67

0.2

1.67

2.4

20%

12

11.8

11.8

0.2

1.67

0.2

1.67

2.4

20%

12

11.7

11.8

0.3

7.9

7.8

0.1

1.25

0.2

2.50

1.6

20%

7.8

7.7

0.2

2.50

0.3

3.75

1.6

20%

7.8

7.8

0.2

10

9.0

1.0

10.00

2.0

20%

10

8.9

1.1

11.00

2.0

20%

10

8.9

Letter Thk.

Max
Allowable

Letter Thk.
Stringer Plate

Gauged

Max
Allowable

Letter Thk.

2nd
3rd
4th
5th
6th
7th
8th
9th
10th
11th
12th
13th
14th
Centre strake
TOPSIDE TOTAL

Operator's Signature :

Surveyor's Signature :

Remarks:

1.1

REMENT ON SHELL AND DECK PLATING


e section dependant on vessel age )

451 / DNB / TEK / UTG / XII / 2016

H DECK PLATING
3rd TRANSVERSE SECTION AT FRAME
NUMBER :20-21
Diminution
S

Max
Allowable

Diminution
P

mm

Diminution
mm

2.50

0.2

1.67

2.4

20%

2.50

0.2

2.50

1.6

20%

2.0

20%

11.00

S
R

= Suspect area (75% - 100%


= Wasted area (beyond corro

Printed in BOLD and BLACK consider re

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)
Printed in BOLD and BLACK consider renewed plate.

TM2-a

n services, Technical Testing & Supplier - Indonesia

Page : VI.2

REPORT OF THICKNESS MEASUREMENT ON SHELL AND DECK PLATING


( one,two or three transverse section dependant on vessel age )
Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

451 / DNB / TEK

16533

SHELL PLATING
1st TRANSVERSE SECTION AT FRAME
NUMBER :16-17
No.
or

STRAKE
POSITION

Org.

Letter Thk.

Diminution
P

Gauged
P

mm

Max
Allowable

Diminution
S

mm

Diminution
mm

2nd TRANSVERSE SECTION AT FRAME


NUMBER : 17-18
No.
or

Org.

Letter Thk.

Diminution
P

Gauged
P

mm

Max
Allowable

Diminution
S

mm

Diminution
mm

3rd TRANSVERS
NUM
No.
or

Org.

Letter Thk.

Gauged
P

Sheer strake

10

8.6

8.6

1.4

14.00

1.4

14.00

2.0

20%

10

8.8

8.7

1.2

12.00

1.3

13.00

2.0

20%

10

9.0

1st below sheer strake

10

8.9

8.9

1.1

11.00

1.1

11.00

2.0

20%

10

9.4

9.3

0.6

6.00

0.7

7.00

2.0

20%

10

9.0

2nd

10

8.8

8.9

1.2

12.00

1.1

11.00

2.0

20%

10

9.3

9.2

0.7

7.00

0.8

8.00

2.0

20%

10

9.0

3rd

10

9.2

8.9

0.8

8.00

1.1

11.00

2.0

20%

10

8.8

8.9

1.2

12.00

1.1

11.00

2.0

20%

10

9.0

10

8.9

9.2

1.1

11.00

0.8

8.00

2.0

20%

10

8.6

12

11.8

0.2

1.67

2.4

20%

12

11.8

4th
5th
6th
7th
8th
9th
10th
11th
12th
13th
14th
15th

Keel strake

12

11.7

Operator Signature's :

0.3

2.50

2.4

20%

Surveyor's Signature :

Remarks:
S
R

= Suspect area (75%


= Wasted area (beyo

Printed in BOLD and BLACK c

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

UREMENT ON SHELL AND DECK PLATING


se section dependant on vessel age )

451 / DNB / TEK / UTG / XII / 2016


SHELL PLATING
3rd TRANSVERSE SECTION AT FRAME
NUMBER : 20-21
Gauged

Diminution
P

Max
Allowable

Diminution
S

mm

mm

8.7

1.0

10.00

1.3

9.3

1.0

10.00

9.2

1.0

10.00

8.9

1.0

9.2

1.4

0.2

1.67

Diminution
mm

13.00

2.0

20%

0.7

7.00

2.0

20%

0.8

8.00

2.0

20%

10.00

1.1

11.00

2.0

20%

14.00

0.8

8.00

2.0

20%

2.4

20%

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)
Printed in BOLD and BLACK consider renewed plate.

TM2-b

services, Technical Testing & Supplier - Indonesia

Page : VI.3

REPORT OF THICKNESS MEASUREMENT ON LONGITUDINAL MEMBERS


( one,two or three transverse section dependant on vessel age )
Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

16533

1st TRANSVERSE SECTION AT FRAME


NUMBER :16-17
STRUCTURAL

No.
or

Org.

MEMBER

Letter

Thk.

DLG W

10
12
10
12

9.7
11.9
9.8
12.0

9.7
11.9

DLG F
DLG W

10

DLG F

Gauged

Diminution
P

mm
0.3
0.1
0.2
0.0

%
3.00
0.83
2.00
0.00

Max
Allowable

Diminution
S

mm
0.3
0.1

%
3.00
0.83

Diminution

451 / D

2nd TRANSVERSE SECTION AT FRAME


NUMBER : 21-22
No.
or

Org.

mm

Letter

Thk.

2.0
2.4
2.0
2.4

20%
20%
20%
20%

10

10
12
10
12

9.8
11.9
9.9
11.8

9.8
12.0

11

Diminution
P

Gauged

mm
0.2
0.1
0.1
0.2

%
2.00
0.83
1.00
1.67

Max
Allowable

Diminution
S

mm
0.2
0.0

Diminution

%
2.00
0.00

3rd TRAN
No.
or

Org.

mm

Letter

Thk.

2.0
2.4
2.0
2.4

20%
20%
20%
20%

10

10
12
10
12
10
12
8
12
16
25
16
25
25
25

11
12

DLG W
DLG F
SSWF W

11

SSWF F
BG W

12

BG F
BG W

13

BG F
BG W
BG F

14

8
12
16
25
16
25
25
25

7.8
11.7
14.7
24.7
14.8
24.8
24.8
24.9

8.0
11.8

0.2
0.3
1.3
0.3
1.2
0.2
0.2
0.1

2.50
2.50
8.13
1.20
7.50
0.80
0.80
0.40

0.0
0.2

0.00
1.67

1.6
2.4
3.2
5.0
3.2
5.0
5.0
5.0

20%
20%
20%
20%
20%
20%
20%
20%

12
13
13
14
15

BG W
BG F

Operator Signature's :

8
12
16
25
16
12
25
16
25
25

7.8
11.7
14.7
24.7

24.8
14.7
24.9
24.8

7.8
11.8

14.7
11.8
24.7
14.8

0.2
0.3
1.3
0.3

0.2
1.3
0.1
0.2

Surveyor's Signature :

2.50
2.50
8.13
1.20

0.80
8.13
0.40
0.80

0.2
0.2

1.3
0.2
0.3
1.2

2.50
1.67

1.6
2.4
3.2
5.0
3.2
2.4
5.0
3.2
5.0
5.0

8.13
1.67
1.20
7.50

20%
20%
20%
20%
20%
20%
20%
20%
20%
20%

13
14
15
16

Remarks:
S
R

= Suspect a
= Wasted ar

Printed in BOLD and

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

REMENT ON LONGITUDINAL MEMBERS


e section dependant on vessel age )

ion services, Technical Testing & Supplier - Indonesia

451 / DNB / TEK / UTG / XII / 2016


3rd TRANSVERSE SECTION AT FRAME
NUMBER :37-38
Gauged
P

9.6
11.8
9.8
11.8
9.8
11.8
7.8
11.8
14.6
24.7
14.7
24.8
24.8
24.0

9.6
11.7
9.7
11.8
7.9
7.8
11.8
14.7
24.6
14.7
24.8

Diminution
P

mm
0.4
0.2
0.2
0.2
0.2
0.2
0.2
0.2
1.4
0.3
1.3
0.2
0.2
1.0

%
4.00
1.67
2.00
1.67
2.00
1.67
2.50
1.67
8.75
1.20
8.13
0.80
0.80
4.00

Max
Allowable

Diminution
S

mm
0.4
0.3
0.3
0.2

%
4.00
2.50
3.00
1.67

0.2
0.2
1.3
0.4
1.3
0.2

2.50
1.67
8.13
1.60
8.13
0.80

Diminution
mm

2.0
2.4
2.0
2.4
2.0
2.4
1.6
2.4
3.2
5.0
3.2
5.0
5.0
5.0

20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)
Printed in BOLD and BLACK consider renewed plate.

TM3

Page :

VI.4

REPORT OF THICKNESS MEASUREMENT ON TRANVERSE STRUCTURAL MEMBERS


IN THE CARGO OIL AND WATER BALLAST TANK
Ship's Name:

Class Id. No:

Report No:

TB. ADAM TUG 3

TANK DESCRIPTION :

AFTER PEAK TANK

LOCATION OF STRUCTURE :

INTERNALS

STRUCTURAL MEMBER

451 / DNB / TEK / UTG / XII / 2016

16533

FRAME :

ITEM

Orig.
Thk.
mm

10
10
10
8
10
10
10
10
10
10
8
10
8
8
12
10

9.2
9.2
9.3
7.8
8.8
9.8
9.8
9.8
9.8
9.2
7.8
9.2
7.8
7.7
11.9
9.8

-1

Gauged

Diminution
P

mm

Diminution
S

mm

Max. Allowable
Diminution
mm

PLATE"
1. DT B
2. DT B
3. DT B
4. DLG
5. DLG
6. SSWF
SSWF
7. BT B
8. TB P
9. BT B
10. BG W
BG F
11. BG W
BG F

Operator's Signature :

PLATE
PLATE
PLATE
WEB
FACE
WEB
FACE
WEB
FACE
PLATE
PLATE
PLATE
WEB
FACE
WEB
FACE

Surveyor's Signature :

9.2
9.2
7.8
8.7

9.8
9.8
9.2
7.8
9.2
7.8
7.7

0.8
0.8
0.7
0.2
1.2
0.2
0.2
0.2
0.2
0.8
0.2
0.8
0.2
0.3
0.1
0.2

8.00
8.00
7.00
2.50
12.00
2.00
2.00
2.00
2.00
8.00
2.50
8.00
2.50
3.75
0.83
2.00

0.8
0.8
0.2
1.3

8.00
8.00
2.50
13.00

0.2
0.2
0.8
0.2
0.8
0.2
0.3

2.00
2.00
8.00
2.50
8.00
2.50
3.75

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

2.0
2.0
2.0
1.6
2.0
2.0
2.0
2.0
2.0
2.0
1.6
2.0
1.6
1.6
2.4
2.0

Hendra Bagus Kurniawa


`
PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANVERSE STRUCTURAL MEMBERS


IN THE CARGO OIL AND WATER BALLAST TANK
Ship's Name:

Class Id. No:

Report No:

039 / DNB / TEK / UTG / XI / 2015

TANK DESCRIPTION :
LOCATION OF STRUCTURE :

STRUCTURAL MEMBER

AFTER PEAK TANK


INTERNALS

FRAME :

ITEM

Orig.
Thk.
mm

Gauged

Diminution

Diminution

mm

9.3
9.2
9.3
7.9
9.0
9.8
9.9
9.8
9.6
9.3
7.8

9.2
9.0
9.3
7.9
8.8

0.7
0.8
0.7
0.1
1.0
0.2
0.1
0.2
0.4
0.7
0.2
0.7
0.1
0.2

7.00
8.00
7.00
1.25
10.00
2.00
1.00
2.00
4.00
7.00
2.50
7.00
1.25
2.50

0.2
0.2

1.67
2.00

mm

Max. Allowable
Diminution
mm

PLATE"
1. DT B
2. DT B
3. DT B
4. DLG
5. DLG
6. SSWF
SSWF
7. BT B
8. TB P
9. BT B
10. BG W
BG F
11. BG W
BG F
12. BG W
BG F

Operator's Signature :

PLATE
PLATE
PLATE
WEB
FACE
WEB
FACE
WEB
FACE
PLATE
PLATE
PLATE
WEB
FACE
WEB
FACE
WEB
FACE

10
10
10
8
10
10
10
10
10
10
8
10
8
8
12
10
12
10

Surveyor's Signature :

9.8
9.8
9.1
7.9

9.3
7.9
7.8

7.8
7.8
11.8
9.9

11.8
9.8

0.8
1.0
0.7
0.1
1.2

8.00
10.00
7.00
1.25
12.00

0.2
0.2
0.9
0.1

2.00
2.00
9.00
1.25

0.2
0.2
0.2
0.1

2.50
2.50
1.67
1.00

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa

2.0
2.0
2.0
1.6
2.0
2.0
2.0
2.0
2.0
2.0
1.6
2.0
1.6
1.6
2.4
2.0
2.4
2.0

PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANVERSE STRUCTURAL MEMBERS


IN THE CARGO OIL AND WATER BALLAST TANK
Ship's Name:

Class Id. No:

Report No:

039 / DNB / TEK / UTG / XI / 2015

TANK DESCRIPTION :
LOCATION OF STRUCTURE :

STRUCTURAL MEMBER

AFTER PEAK TANK


INTERNALS

FRAME :

ITEM

Orig.
Thk.
mm

Gauged

Diminution

Diminution

mm

mm

Max. Allowable
Diminution
mm

PLATE"
1. DT B
2. DT B
3. DT B
4. DLG
5. DLG
6. SSWF
SSWF
7. BT B
8. TB P
9. BT B
10. BT B
11. BG W
BG F
12. BG W
BG F
13. BG W
BG F

Operator's Signature :

PLATE
PLATE
PLATE
WEB
FACE
WEB
FACE
WEB
FACE
PLATE
PLATE
PLATE
PLATE
WEB
FACE
WEB
FACE
WEB
FACE

Surveyor's Signature :

10
10
10
8
10
10
10
10
10
10
8
10
10
8
8
12
10
12
10

9.3
9.2
7.8
8.9
9.8
9.6
9.6
9.8
9.3
7.9

9.2
9.3
9.2
7.9
8.8

9.7
9.7
7.9

9.2

9.2

9.3
7.9
7.8
11.9
9.8
12.0
9.7

9.1

11.7
9.7

0.7
0.8
0.2
1.1
0.2
0.4
0.4
0.2
0.7
0.1
0.8
0.7
0.1
0.2
0.1
0.2
0.0
0.3

7.00
8.00
2.50
11.00
2.00
4.00
4.00
2.00
7.00
1.25
8.00
7.00
1.25
2.50
0.83
2.00
0.00
3.00

0.8
0.7
0.8
0.1
1.2

8.00
7.00
8.00
1.25
12.00

0.3
0.3

3.00
3.00

0.1
0.8
0.9

1.25
8.00
9.00

0.3
0.3

2.50
3.00

2.0
2.0
2.0
1.6
2.0
2.0
2.0
2.0
2.0
2.0
1.6
2.0
2.0
1.6
1.6
2.4
2.0
2.4
2.0

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANVERSE STRUCTURAL MEMBERS


IN THE CARGO OIL AND WATER BALLAST TANK
Ship's Name:

Class Id. No:

Report No:

039 / DNB / TEK / UTG / XI / 2015

TANK DESCRIPTION :
LOCATION OF STRUCTURE :

STRUCTURAL MEMBER

FORE PEAK TANK


INTERNALS

FRAME :

ITEM

46

Orig.
Thk.
mm

Gauged
P

mm

10
12
10
10
12
10
10

9.7
11.8
9.7
9.7
11.7
9.8
9.8

9.8
11.8
9.7
9.7
11.7
9.8
9.8

0.3
0.2
0.3
0.3
0.3
0.2
0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATE"
1. DT S
2. SS B
3. SS S
4. SS S
5. SS B
6. BTWF

Operator's Signature :

STIFFENER
PLATE
STIFFENER
STIFFENER
PLATE
WEB
FACE

Surveyor's Signature :

3.00
1.67
3.00
3.00
2.50
2.00
2.00

0.2
0.2
0.3
0.3
0.3
0.2
0.2

2.00
1.67
3.00
3.00
2.50
2.00
2.00

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa

2.0
2.4
2.0
2.0
2.4
2.0
2.0

PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANVERSE STRUCTURAL MEMBERS


IN THE CARGO OIL AND WATER BALLAST TANK
Ship's Name:

Class Id. No:

Report No:

039 / DNB / TEK / UTG / XI / 2015

TANK DESCRIPTION :
LOCATION OF STRUCTURE :

STRUCTURAL MEMBER

FORE PEAK TANK


INTERNALS

FRAME :

ITEM

47

Orig.
Thk.
mm

Gauged
P

mm

10
12
10
10
12
10
10

8.7
11.6
8.7
8.7
11.7
9.8
9.8

8.8
11.7
8.7
8.7
11.7
9.8
9.7

1.3
0.4
1.3
1.3
0.3
0.2
0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATE"
1. DT S
2. SS B
3. SS S
4. SS S
5. SS B
6. BTWF

Operator's Signature :

STIFFENER
PLATE
STIFFENER
STIFFENER
PLATE
WEB
FACE

Surveyor's Signature :

13.00
3.33
13.00
13.00
2.50
2.00
2.00

1.2
0.3
1.3
1.3
0.3
0.2
0.3

12.00
2.50
13.00
13.00
2.50
2.00
3.00

2.0
2.4
2.0
2.0
2.4
2.0
2.0

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANVERSE STRUCTURAL MEMBERS


IN THE CARGO OIL AND WATER BALLAST TANK
Ship's Name:

Class Id. No:

Report No:

039 / DNB / TEK / UTG / XI / 2015

TANK DESCRIPTION :
LOCATION OF STRUCTURE :

STRUCTURAL MEMBER

FORE PEAK TANK


INTERNALS

FRAME :

ITEM

48

Orig.
Thk.
mm

Gauged
P

mm

10
12
12
12
10

9.8
11.8
11.8
11.8
9.8

9.4

0.2
0.2
0.2
0.2
0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATE"
1. TB P
2. TB S W
3. TB S W
4. TB S W
5. TB P

Operator's Signature :

PLATE
FLANGE
FLANGE
FLANGE
PLATE

Surveyor's Signature :

11.7

2.00
1.67
1.67
1.67
2.00

0.6

6.00

0.3

2.50

2.0
2.4
2.4
2.4
2.0

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

EMENT ON TRANVERSE STRUCTURAL MEMBERS


OIL AND WATER BALLAST TANK

451 / DNB / TEK / UTG / XII / 2016

pection services, Technical Testing & Supplier - Indonesia

Max. Allowable
Diminution
%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%

TM4

VII.2

EMENT ON TRANVERSE STRUCTURAL MEMBERS


OIL AND WATER BALLAST TANK

039 / DNB / TEK / UTG / XI / 2015

Max. Allowable
Diminution
%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%

TM4

pection services, Technical Testing & Supplier - Indonesia

VII.3

EMENT ON TRANVERSE STRUCTURAL MEMBERS


OIL AND WATER BALLAST TANK

039 / DNB / TEK / UTG / XI / 2015

Max. Allowable
Diminution
%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%

TM4

pection services, Technical Testing & Supplier - Indonesia

VII.4

EMENT ON TRANVERSE STRUCTURAL MEMBERS


OIL AND WATER BALLAST TANK

039 / DNB / TEK / UTG / XI / 2015

Max. Allowable
Diminution
%
20%
20%
20%
20%
20%
20%
20%

TM4

pection services, Technical Testing & Supplier - Indonesia

VIII.2

EMENT ON TRANVERSE STRUCTURAL MEMBERS


OIL AND WATER BALLAST TANK

039 / DNB / TEK / UTG / XI / 2015

Max. Allowable
Diminution
%
20%
20%
20%
20%
20%
20%
20%

TM4

pection services, Technical Testing & Supplier - Indonesia

VIII.3

EMENT ON TRANVERSE STRUCTURAL MEMBERS


OIL AND WATER BALLAST TANK

039 / DNB / TEK / UTG / XI / 2015

Max. Allowable
Diminution
%
20%
20%
20%
20%
20%

TM4

pection services, Technical Testing & Supplier - Indonesia

VIII.4

REPORT OF THICKNESS MEASUREMENT ON TRANSVERSE BULKHEADS


(IN THE CARGO OIL TANK AND WATER BALLAST TANK)
Ship's Name:

Class Id. No:


TB. ADAM TUG 3

TANK/HOLD DESCRIPTION:
LOCATION OF STRUCTURE:

Report No.
16533

451 / DNB / TEK / UTG / XII / 2016

TRANSVERS BULHEAD

STRUCTURAL COMPONENT (PLATING/STIFFENER)

Orig.
Thk.
mm

FRAME No. :
Gauged

4
Diminution

Diminution

mm

7.9
7.8

7.8

0.1
0.2

mm

Max. Allowable
Diminution
mm

PLATING :
1
2

Operator's Signature :

8
8

Surveyor's Signature :

1.25
2.50

0.2

2.50

1.6
1.6

Remarks:
S

= Suspect area (75% - 100% of corrosion limit)

= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANSVERSE BULKHEADS


(IN THE CARGO OIL TANK AND WATER BALLAST TANK)
Ship's Name:

Class Id. No:


TB. ADAM TUG 3

TANK/HOLD DESCRIPTION:
LOCATION OF STRUCTURE:

Report No.
16533

451 / DNB / TEK / UTG / XII / 2016

TRANSVERS BULHEAD

STRUCTURAL COMPONENT (PLATING/STIFFENER)

Orig.
Thk.
mm

FRAME No. :
Gauged

mm

7.8
7.8

7.9
7.8

0.2
0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATING :
1
2

Operator's Signature :

8
8

Surveyor's Signature :

2.50
2.50

0.1
0.2

1.25
2.50

1.6
1.6

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANSVERSE BULKHEADS


(IN THE CARGO OIL TANK AND WATER BALLAST TANK)
Ship's Name:

Class Id. No:


TB. ADAM TUG 3

TANK/HOLD DESCRIPTION:
LOCATION OF STRUCTURE:

Report No.
16533

451 / DNB / TEK / UTG / XII / 2016

TRANSVERS BULHEAD

STRUCTURAL COMPONENT (PLATING/STIFFENER)

Orig.
Thk.
mm

FRAME No. :
Gauged

14

mm

7.8
7.9
7.8

7.8

0.2
0.1
0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATING :
1
2
3
4

Operator's Signature :

8
8
8
8

Surveyor's Signature :

7.8
7.8

2.50
1.25
2.50

0.2

2.50

0.2
0.2

2.50
2.50

1.6
1.6
1.6
1.6

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANSVERSE BULKHEADS


(IN THE CARGO OIL TANK AND WATER BALLAST TANK)
Ship's Name:

Class Id. No:


TB. ADAM TUG 3

TANK/HOLD DESCRIPTION:
LOCATION OF STRUCTURE:

Report No.
16533

451 / DNB / TEK / UTG / XII / 2016

TRANSVERS BULHEAD

STRUCTURAL COMPONENT (PLATING/STIFFENER)

Orig.
Thk.
mm

FRAME No. :
Gauged

26

mm

7.8

7.8
7.7

0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATING :
1
2

Operator's Signature :

8
8

Surveyor's Signature :

2.50

0.2
0.3

2.50
3.75

1.6
1.6

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANSVERSE BULKHEADS


(IN THE CARGO OIL TANK AND WATER BALLAST TANK)
Ship's Name:

Class Id. No:


TB. ADAM TUG 3

TANK/HOLD DESCRIPTION:
LOCATION OF STRUCTURE:

Report No.
16533

451 / DNB / TEK / UTG / XII / 2016

TRANSVERS BULHEAD

STRUCTURAL COMPONENT (PLATING/STIFFENER)

Orig.
Thk.
mm

FRAME No. :
Gauged

32

mm

7.8
7.8

7.8
7.8

0.2
0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATING :
1
2

Operator's Signature :

8
8

Surveyor's Signature :

2.50
2.50

0.2
0.2

2.50
2.50

1.6
1.6

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANSVERSE BULKHEADS


(IN THE CARGO OIL TANK AND WATER BALLAST TANK)
Ship's Name:

Class Id. No:


TB. ADAM TUG 3

TANK/HOLD DESCRIPTION:
LOCATION OF STRUCTURE:

Report No.
16533

451 / DNB / TEK / UTG / XII / 2016

LONGITUDINAL BULHEAD

STRUCTURAL COMPONENT (PLATING/STIFFENER)

Orig.
Thk.
mm

FRAME No. :
Gauged

9 - 12

mm

7.8
7.8
7.8
7.8

7.8
7.6
7.8
7.7

0.2
0.2
0.2
0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATING :
1
2
3
4

Operator's Signature :

8
8
8
8

Surveyor's Signature :

2.50
2.50
2.50
2.50

0.2
0.4
0.2
0.3

2.50
5.00
2.50
3.75

1.6
1.6
1.6
1.6

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANSVERSE BULKHEADS


(IN THE CARGO OIL TANK AND WATER BALLAST TANK)
Ship's Name:

Class Id. No:


TB. ADAM TUG 3

TANK/HOLD DESCRIPTION:
LOCATION OF STRUCTURE:

Report No.
16533

451 / DNB / TEK / UTG / XII / 2016

LONGITUDINAL BULHEAD

STRUCTURAL COMPONENT (PLATING/STIFFENER)

Orig.
Thk.
mm

FRAME No. :
Gauged

18 - 24

mm

8.0
8.0

8.0
8.0

0.0
0.0

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATING :
1
2

Operator's Signature :

8
8

Surveyor's Signature :

0.00
0.00

0.0
0.0

0.00
0.00

1.6
1.6

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON TRANSVERSE BULKHEADS


(IN THE CARGO OIL TANK AND WATER BALLAST TANK)
Ship's Name:

Class Id. No:


TB. ADAM TUG 3

TANK/HOLD DESCRIPTION:
LOCATION OF STRUCTURE:

Report No.
16533

451 / DNB / TEK / UTG / XII / 2016

LONGITUDINAL BULHEAD

STRUCTURAL COMPONENT (PLATING/STIFFENER)

Orig.
Thk.
mm

FRAME No. :
Gauged

3 - 14

mm

7.8
7.8
7.9
7.8

7.5
7.8
7.6
7.8

0.2
0.2
0.1
0.2

Diminution

Diminution

mm

Max. Allowable
Diminution
mm

PLATING :
1
2
3
4

Operator's Signature :

8
8
8
8

Surveyor's Signature :

2.50
2.50
1.25
2.50

0.5
0.2
0.4
0.2

6.25
2.50
5.00
2.50

1.6
1.6
1.6
1.6

Remarks:
S
R

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

Purwo Agung A.

Hendra Bagus Kurniawa


PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

ASUREMENT ON TRANSVERSE BULKHEADS

L TANK AND WATER BALLAST TANK)

451 / DNB / TEK / UTG / XII / 2016

Max. Allowable
Diminution
%
20%
20%

TM5

spection services, Technical Testing & Supplier - Indonesia

IX.2

ASUREMENT ON TRANSVERSE BULKHEADS

L TANK AND WATER BALLAST TANK)

451 / DNB / TEK / UTG / XII / 2016

Max. Allowable
Diminution
%
20%
20%

TM5

spection services, Technical Testing & Supplier - Indonesia

IX.3

ASUREMENT ON TRANSVERSE BULKHEADS

L TANK AND WATER BALLAST TANK)

451 / DNB / TEK / UTG / XII / 2016

Max. Allowable
Diminution
%
20%
20%
20%
20%

TM5

spection services, Technical Testing & Supplier - Indonesia

IX.4

ASUREMENT ON TRANSVERSE BULKHEADS

L TANK AND WATER BALLAST TANK)

451 / DNB / TEK / UTG / XII / 2016

Max. Allowable
Diminution
%
20%
20%

TM5

spection services, Technical Testing & Supplier - Indonesia

IX.5

ASUREMENT ON TRANSVERSE BULKHEADS

L TANK AND WATER BALLAST TANK)

451 / DNB / TEK / UTG / XII / 2016

Max. Allowable
Diminution
%
20%
20%

TM5

spection services, Technical Testing & Supplier - Indonesia

IX.6

ASUREMENT ON TRANSVERSE BULKHEADS

L TANK AND WATER BALLAST TANK)

451 / DNB / TEK / UTG / XII / 2016

Max. Allowable
Diminution
%
20%
20%
20%
20%

TM5

spection services, Technical Testing & Supplier - Indonesia

X.2

ASUREMENT ON TRANSVERSE BULKHEADS

L TANK AND WATER BALLAST TANK)

451 / DNB / TEK / UTG / XII / 2016

Max. Allowable
Diminution
%
20%
20%

TM5

spection services, Technical Testing & Supplier - Indonesia

X.3

ASUREMENT ON TRANSVERSE BULKHEADS

L TANK AND WATER BALLAST TANK)

451 / DNB / TEK / UTG / XII / 2016

Max. Allowable
Diminution
%
20%
20%
20%
20%

TM5

spection services, Technical Testing & Supplier - Indonesia

X.4

REPORT OF THICKNESS MEASUREMENT ON MISCELLANEOUS MEMBERS

Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

STRUCTURAL MEMBER : KORT NOZZLE


LOCATION OF STRUCTURE :
Orig.
DESCRIPTION
Thk.
mm
PLATE" (TOP)
1
10
2
10
3
10
4
10
5
10
6
10
7
10
8
10
9
10
10
10
11
10
12
10
13
10
14
10
15
10
16
10
17
10
18
10

Operator's Signature :

451 / DNB / TEK / UTG / XII / 2016

16533

Gauged
P

8.4
9.0
8.8
8.8
8.9
9.0
8.9
8.8
8.9
9.0
8.8
8.9
8.7
8.8
9.0
8.9
8.9
8.9

8.4
8.9
9.0
8.8
8.9
8.8
8.7
8.8
8.9
8.8
8.9
8.8
8.9
8.8
8.9
8.9
8.9
8.9

Diminution
P
mm
%
1.6
1.0
1.2
1.2
1.1
1.0
1.1
1.2
1.1
1.0
1.2
1.1
1.3
1.2
1.0
1.1
1.1
1.1

16.00
10.00
12.00
12.00
11.00
10.00
11.00
12.00
11.00
10.00
12.00
11.00
13.00
12.00
10.00
11.00
11.00
11.00

Diminution
S
mm
%
S

1.6
1.1
1.0
1.2
1.1
1.2
1.3
1.2
1.1
1.2
1.1
1.2
1.1
1.2
1.1
1.1
1.1
1.1

16.00
11.00
10.00
12.00
11.00
12.00
13.00
12.00
11.00
12.00
11.00
12.00
11.00
12.00
11.00
11.00
11.00
11.00

Max. Allowable
Diminution
mm
%
S

2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00
2.00

Surveyor's Signature :

SKETCH
ORIENTATION DIAGRAM SHOWING PLATE/ITEM IDENTIFIC
AND LOCATION OF GAUGING

20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%

Remarks:
N
S
R

Purwo Agung A.

Hendra Bagus Kurniawa

= 'Replate area
= Suspect area (75% - 100% of corrosi
= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON MISCELLANEOUS MEMBERS

Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

STRUCTURAL MEMBER : SKEG


LOCATION OF STRUCTURE :
FR 4 - 10
Orig.
DESCRIPTION
Thk.
mm
PLATE" (TOP)
1
10
2
12
3
10

Operator's Signature :

451 / DNB / TEK / UTG / XII / 2016

16533

Gauged
A

9.0
11.9
9.0

9.0
11.8
9.0

Diminution
A
mm
%

Diminution
F
mm
%

Max. Allowable
Diminution
mm
%

1.0
0.1
1.0

1.0
0.2
1.0

2.00
2.40
2.00

10.00
0.83
10.00

10.00
1.67
10.00

Surveyor's Signature :

SKETCH
ORIENTATION DIAGRAM SHOWING PLATE/ITEM IDENTIFIC
AND LOCATION OF GAUGING

20%
20%
20%

Remarks:
N
S
R

Purwo Agung A.

Hendra Bagus Kurniawa

= 'Replate area
= Suspect area (75% - 100% of corrosi
= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REPORT OF THICKNESS MEASUREMENT ON MISCELLANEOUS MEMBERS

Ship's Name:

Class Id. No:

Report No.

TB. ADAM TUG 3

STRUCTURAL MEMBER : RUDDER BLADE


LOCATION OF STRUCTURE :
Orig.
DESCRIPTION
Thk.
mm
PLATE" (TOP)
1
20
2
20

Operator's Signature :

451 / DNB / TEK / UTG / XII / 2016

16533

Gauged
P

20.0
20.0

20.0
20.0

Diminution
P
mm
%

Diminution
S
mm
%

Max. Allowable
Diminution
mm
%

0.0
0.0

0.0
0.0

4.00
4.00

0.00
0.00

0.00
0.00

Surveyor's Signature :

SKETCH
ORIENTATION DIAGRAM SHOWING PLATE/ITEM IDENTIFIC
AND LOCATION OF GAUGING

20%
20%

Remarks:
N
S
R

Purwo Agung A.

Hendra Bagus Kurniawa

= 'Replate area
= Suspect area (75% - 100% of corrosi
= Wasted area (beyond corrosion limit)

Printed in BOLD and BLACK consider renewed plate.

PT. DALUT NUSANTARA BARU - Inspection services, Technical Testing & Supplier - Indonesia

Page :

REMENT ON MISCELLANEOUS MEMBERS

451 / DNB / TEK / UTG / XII / 2016

SKETCH
ORIENTATION DIAGRAM SHOWING PLATE/ITEM IDENTIFICATION
AND LOCATION OF GAUGING

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)
Printed in BOLD and BLACK consider renewed plate.

on services, Technical Testing & Supplier - Indonesia

II.2

REMENT ON MISCELLANEOUS MEMBERS

451 / DNB / TEK / UTG / XII / 2016

SKETCH
ORIENTATION DIAGRAM SHOWING PLATE/ITEM IDENTIFICATION
AND LOCATION OF GAUGING

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)
Printed in BOLD and BLACK consider renewed plate.

on services, Technical Testing & Supplier - Indonesia

III.2

REMENT ON MISCELLANEOUS MEMBERS

451 / DNB / TEK / UTG / XII / 2016

SKETCH
ORIENTATION DIAGRAM SHOWING PLATE/ITEM IDENTIFICATION
AND LOCATION OF GAUGING

= Suspect area (75% - 100% of corrosion limit)


= Wasted area (beyond corrosion limit)
Printed in BOLD and BLACK consider renewed plate.

on services, Technical Testing & Supplier - Indonesia

IV.2

PT. DALUT NUSANTARA BARU


Inspection Services, Technical Testing & Supplier

GENERAL PARTICULARS
Ships Name
Type of Ship
IMO Number
Class No./Register No.
Flag
LOA
Breadth
Depth
Draft
Gross Tonage
Dead Weight
Date of Build
Classification society

:
:
:
:
:
:
:
:
:
:
:
:
:

TB.Adam Tug 3
Tug Boat
9611204
16533
INDONESIA
23,50 M
7,32 M
3,50 M
2,91 M
BIRO KLASIFIKASI INDONESIA

KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.

KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.

KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.
KMP.

Das könnte Ihnen auch gefallen