Sie sind auf Seite 1von 6

IS : 10124 ( Part 6 )A@88

( Reaffirmed 1998 )

Standard
SPECIFICATION -FOR
FABRICATED PVC FITTINGS FOR
POTABLE WATER SUPPLIES
ldian

PART 6

SPECIFIC

REQUIREMENTS
WITH
METALLIC

FOR FLANGED
FLANGES

TAIL

PIECES

( First Revision)
First Reprint DECEMBER 1993

UDC

BUREAU
MANAK

621.643.4.069.1

OF
BHAVAN,

[678.743.22]:696.117

INDIAN

STANDARDS

9
BAHADUR
SHAH
NEW DELHI 110002

ZAFAR

MARG

February

1989

1$:10~22A(Past
6.)-1988

Indian Standard

SPECIFICATIONFOR
FABRICATEDPVCFITTINGSFOR
POTABLEWATERSUPPLIES
PART 6

SPECIFIC

REQUIREMENTS
WITH

METALLIC

0.

FORE

( Part 6 ) ( First Rcvision ) was adopted by the Bureau of Indian


Standards on 20 June
1988, after the draft
finalized by the Sanitary Appliances and Water
Fittings Sectional Committee had been approved
by the Civil Engineering Division Council.

sockets
for straight
caps

5 Specific requirements

Part

6 Specific requirements for flanged tail


pieces with metallic flanges
7 Specific requirements
for threaded
adaptors
8 Specific requirements for 90 bends

Specific
Specific
Specific
Specific
Specific

requirements
requirements
requirements
requirements
requirements

for
for
for
for
for

60 bends
45 bends
30 bends
22+ bends
1I$ bends

0.4 For the purpose of deciding whether a particular requirement of this standard is complied
with, the final value, observed or calculated,
expressing the result of a test, shall be rounded
off in accordance with IS : 2-19607. The number
of significant places retained in the rounded off
value should be the same as that of the specified
value in this standard.

for equal tees

*Specification for unplasticized PVC pipes for potable


water supplies ( second revision ).
+Rules for rounding off numerical values ( revised ).

PVC pipes for potable

1.SCOPE
1.1This standard
( Part 6 )
requirements for manufacture,
marking for fabricated PVC
with metallic flanges for potable

9
10
11
12
13

0.3.1 Part 1 of this series deals with the general requirements applicable to all fabricated PVC
fittings. Specific requirements of different types
of fittings are covered in separate parts of the
siandard.
This standard (Part 6 ) deals with
the specific requirements for flanged tail pieces
with metallic flanges. This part ( Part 6 ) was
first published in 1982. The present revision has
been taken up to extend the size of fittings to
630 mm in line with the sizes of pipes specified
in IS : 4985-1958*.

PVC fittings
parts of the

Part

*pecification for unplasticized


water supplies ( second revish
).

PIECES

FLAYGES

Part
Part
Part
Part
Part

0.2 The fabricated PVC fittings are to be used


for jointing to the PVC pipes covered
by
IS : 49851988*.

Part

TAIL

WORD

0.1This Indian Standard

Part

FLANGED

First Revision )

0.3 The requirements of fabricated


are covered in fdllowing thirteen
standard:
Part 1 General requirements
Part 2 Specific requirements for
Part 3 Specific requirements
reducers
Part 4 Specific requirements for

FOR

criteria
for conformity
shall
IS : 10124 ( Part 1 )-1988*.

lays down the


dimensions and
flanged tail pieces
water supplies.

conform

to

2.2 Manufacture
2.2.1 A typical illustration of flanged tail
piece with metallic flange is shown in Fig. 1.

2. REQUIREMENTS
*Specification
water
supplies:
revision ).

2.1 General - The general requirements


for
material, sizes, methods -of test, sampling and
1

for fabricated PVC fittings for


Part 1 General
requirements

potable
(first

IS:10124(Part6)-1988

PVC -FLANGE

METALLIC
FLANGE
BOlti
SIDES PAINTEQ

NOTE - This drawing is intended to define the terms used in Table 1 and is not intended to illustrate specific

design features.

PVC FLANGED TAIL PIECE WITH METALLIC FLANGE


3. MARKING
2.2.2 Dimensicins - The dimensions of flanged
tail pieces with metallic flanges shall comply with
3.1 Each flanged tail piece with m-etallic flange
those given in Table 1 read with Fig. 1.
fitting
mat-ion.shall be marked with the following infor2.2.2.1 The minimum wall thickness of fabricated tail piecessfJlarticular
Dressure class shall
a) Manufacturers
be the sime as thk r&imum
wall thickness of
name or identification
the corresponding pressure class pipe as specified
mark,
in IS : 4985-1988*.
NOTE - For 0.25 MPa pressure class, fabricated tail
b) The size of the flanged tail piece with
pieces should not be made from 0.25 MPa ( Class 1 )
metallic flange and the appropriate class
pressure class pipes. For this, tail pieces made from
( working pressure ) of IS : 4985-1988 to
O-4 MPa ( Class 2 ) pressure class pipe should be used.
which the pressure rating of the fitting
2.2.3 The flanged tail piece may be either plain
corresponds, and
or socketed as agreed between the manufacturer
and the purchaser. In the case of socketed flanged
c) The flanged tail piece with metallic flange
tail piece, the socket dimensions shall comply
shall be marked in colour as indicated
with IS : 10124 ( Part 1 )-1988t.
below for different classes of fittings:
2.2.4 The suitable material for metallic flanges
Class of I;& ing
Colour
shall be cast iron and shall be of a quality not
less than that specified for Grade FG 150 of
Class 1 ( 025 MPa )
Red
IS : 210-1978$.
Class 2 ( 04 MPa )
Blue
FIG. 1

.*Specification for unplasticized PVC pipes for potable


water supplies ( second revision ).
tSpecification for fabricated PVC fittipgs for potable
water supplies : Part 1 General requirements
(first
revision ).
SSpecificdion for grey iron castings ( thtrd revision ).

Class 3 ( 06 MPa )

Green

Class 4 ( 10 MPa )

Yellow

*Specification for unplasticized PVC pipes for potable


water supplies ( second revision ).
2

Is : 10124( Part 6.) - 1988

TABLE

SIZE

DIA G

1 DIMENSIONS OF PVC FLANGED TAIL PIECE WITH METALLIC FLANGES

DIA D

m(Clause 2.2.2, and Fig. 1 )


All dimensions in millimetrcs.
DIA d
T
DIA H
No.
OBHOLES i&a

(2)

(3)

63

125

165

75

145

185

76

90

160

200

91

110

180

220

112

125

210

250

127

(1)

(4)
+ 10
64
-0
-?-l-O
-0
+ 1.0

142

-0
+ 10
-0

f 1.0
-0
+ 10

140

210

250

160

240

285

180

240

285

200

295

340

203

225

295

340

228

250

350

395

253

280

350

395

284

315

400

445

319

355

460

505

359

400

s15

565

405

450

565

615

455

500

620

670

506

-0

+ 10
162
-0
+ 10
183
-0
+ 18
-0

+ 10
-0

+ 1.0
-0
+ 1.0
-0

+ 10
-0

+ 1.0
-0
+ 2.0
-0
+ 2.0
-0

+ 20

685

740

566

630

755

810

637

NOTE -

+ 20
-0

SIZE

(6)

(7)

(8)

(9)

(10)

( 11 1

7.0

19

25

68

101

M 16

7.0

19

2.5

80

121

M 16

9.5

19

3.0

95

136

M 16

95

19

3.0

115

156

M 16

11.0

19

3.0

130

186

M 16

12.5

19

40

145

186

M 16

125

23

40

165

212

M 20

125

23

40

185

212

M 20

160

23

40

205

267

M 20

200

23

4.0

230

267

M 20

20.0

23

12

50

255

322

M 20

200

23

12

5.0

285

322

M 20

24.5

23

12

5.0

320

372

M-20

24.5

23

16

5.0

360

432

MU)

245

28

16

60

-405

483

M 24

28.0

28

16

6.0

455

533

M 24

28.0

28

20

60

505

588

M24

33

20

6.0

565

649

M 24

719

M 27

32.0

+ 2.0

320
33
20
7.0
635
-0
Fabricated tail pieces for sizes 225 mm and above are not generally recommended.

BOLT

(5)

-0
560

kin D%7:

IS : 10124 ( Part 6 ) - 1988


3.1.1 Each flanged tail piece with metallic
flange fitting may also be marked with the
Standard Mark.

produced
to comply with the tequirements
of that
standard
under a well-defined
system of inspection,
testing and quality control which is devised and supervised by BIS and operated by the producer.
Standard
marked products are also continuously checked by BIS
for conformity to that standard as a further safeguard.
Details of conditions under which a licence for the use
of the Standard
Mark may be granted to manufacturers or producers may be obtained from the Bureau
of Indian Standards.

NOTE - The use of the Standard Mark is governed


by the provisions of the Bureau of Indian Standard Act
1986 and the Rules and Regulations ma& thereunder.
The Standard
Mark on products covered by an Indian
Standard conveys the assurance
that they have been

Bureau of In&an Standard


BIS is a statutory
institution
established
under the Bureau of Indian Standards Act, 1986 to
promote harmonious
development
of the activities of standardization,
marking and quality
certification of goods and attending to connected matters in the country.
Copyright
BIS has the copyright of all its publications. No part of these publications may be reproduced
in any form without the prior permission in writing of BIS. This does not preclude the free use,
in the course of implementing the standard, of necessary details, such as symbols an-d sizes, type
Director
Enquiries
relating
to copyright
be addressed
to the
or grade designations.
( Publications ), BIS.
Revisioo of Indian Standards
Indian Standards are reviewed periodically and revised, when necessary and amendments,
if
any, are issued from time to time. Users oflndian
Standards should ascertain that they are in
on this Indian Standard
may be
possession of the latest amendments or edition. Comments
sent to BJS giving the following reference:

Amendments hoed

Date of Issue

Amend No.

BUREAU
Headquarters

Since hbiication

OF INDIAN

Text Affected

STANDARDS

Manak Bhavan, 9 Bahadur Shah Zafar Marg,


Telephones : 331 01 31. 331 13 75

New Delhi 110002


Telegrams : Manaksanstha
1 Common to all Offices )

Regional Offices :
Central

: Manak Bhavan,

NEW DELHJ
Fastetn

Telephone
9 Bahadur Shah Zafar Marg
110002

: l/14 C. I. T. Scheme

311 01 31
I 331 13 75

VII M, V. J. P. Road, Mapiktola

37 86 62

CA LCUT 7 A 700054
Northern

: SC0 445-446, Sector 35-C, CHANDIGARH

160036

53 38 43

Southern

. C. I. T. Campus, IV Cross Road, M 4DRAS

600113

235 02 16

Western

: Manakalaya, E9 MIDC, Marol, Andheri ( East )


ROM BAY 400093
: AHMADABAD,
BANGALORE,
BHOPAL, BHUBANESHWAR,

Branches

FARJDABAD,
GHAZIABAD, GUWAHATI,
HYDERABAD,
LUCKNOW, PATNA, THIRUVANANTHAPURAM.

6 32 92 95

COIMBATORE,
JAI~PUR, KANPUR,

Reprography Unit, BJS, New Delhi, India

Das könnte Ihnen auch gefallen