Sie sind auf Seite 1von 2

01

Circuit Breakers

EOX
Medium Voltage Outdoor Circuit Breaker
PM100725

The best way to reduce your operating costs is to invest in cost effective
solutions. Thats why your medium voltage equipment should be as compact
as possible, very resistant, reliable, and require minimal maintenance.

PM100726

Based on over 25 years of experience in proven vacuum technology, our EOX


Outdoor Vacuum Circuit Breakers are built with the highest
quality materials and using state-of-the-art manufacturing techniques. These
breakers are guaranteed for at least 10,000 operations at nominal current
and come with our Schneider Electric Best in the Industry warranty. Our
maintenance-free design requires no adjustments. They offer you security,
peace of mind and the lowest life cycle costs of any medium voltage outdoor
breaker available on the market today.
At Schneider Electric, we know the important role that our circuit breakers play
in your daily activities. Our time-tested, simple design, with
minimal moving parts and a single rotating axle mechanism, allows us to
commit to our products quality. EOX benefits from easy standardization across
multiple system requirements for new or existing substations. EOX circuit
breakers offer you flexibility through mechanical and electrical
modularity. Reliable and trustworthy, Schneider Electric is the world leader in
vacuum interrupter technology.

Matching your needs

CUSTOMER BENEFITS
Proven vacuum switching technology
Highest quality materials suitable
for agressive environments
State-of-the-art manufacturing
Lowest life-cycle costs in industry yet
maintenance free - no adjustments
Time tested, simple design that is
compact yet flexible
User friendly
Full compliance with ANSI and IEC
Standards

EOX is a three pole outdoor vacuum circuit breaker ranging from 15 kV up to


27 kV, 1200 A up to 2,000 A with interrupting capacities up to
40 kA. This particular breaker has been especially designed for the North
American market and it responds to your various application requirements.
EOX is manufactured and tested in full compliance with applicable ANSI
standards while IEC standards are also available. Our circuit breakers are
available with local and remote trip/close features, manual and electrical
spring charging, different switching cycles and a wide variety of protection and
metering current transformers.

Adaptability and endurance


EOX vacuum circuit breakers are designed and built to operate under the most
severe operating conditions:
High altitudes levels
High pollution
High humidity levels
Marine climates
Regions with high seismic activity.

PM100727

The NEMA 3R designed cabinet is built on anti-corrosion structural steel; the


bushings are made of porcelain. EOXs separate support frame fitted with
height-adjustable legs can also be installed on a mobile trailer to better adapt
to your application needs.

NRJED311015EN.indd 2

24/06/2011 11:41:37

Medium Voltage Outdoor Circuit Breakers

02

EOX

Testing & Installation


At Schneider Electric, we perform a series of tests
that ensure the physical and electrical integrity of
every breaker before it is delivered to you. In order
to offer the simplest of solutions, our circuit breakers are shipped to your site fully assembled. All
that is left to do is to adjust the legs to the desired
installation height.

BLV Circuit breaker

PM100728

The BLV circuit breaker of the EOX provides


state-of-the-art vacuum technology.
Thanks to its M5S mechanism it offers:
Reduced number of moving parts for higher
reliability and stable dielectric strength
One single rotating axle for simplicity and
safety of operation
10,000 operations with very low maintenance
for a long service life.

Adjustable Height

Dimensions
EOX

kV
A

15/15.5
1250

15/15.5
1250

27.6
1250

27.6
1250

15.5/25.8
2000

15.5/25.8
2000

inches

mm

inches

mm

inches

mm

47.3

1,201

47.3

1,201

47.3

1,201

24.2

615

24.2

615

24.2

615

Cmin

108.3

2,751

108.3

2,751

108.3

2,751

Cmax

120.1

3,051

120.1

3,051

120.1

3,051

13.0

330

15.0

381

15

381

51.3

1,303

55.3

1,405

51.3

1,405

LV
cabinet

25 x 33

635 x 838

25 x 33

635 x 838

25 x 33

635 x 838

Weight

1,760 lbs

800 Kg

1,936 lbs

880 Kg

1,980 lbs

900 Kg

Doghouse ANSI characteristics


EOX 24

Ur

kV

Ir

1200

2000

2000

Isc*

kA

20

25

25

31.5

25

25

31.5

Isc**

kA

25

31.5

31.5

40

25

25

31.5

Capacitive
breaking current
-Single
-Back-to-Back

2000

27.6

27.6

27.6

1200

2000

2000

400

400

BIL

kVp

95/110

125/150

Chopped wave

kVp

n/r 142/126

n/r n/r

125

125/150

Max dielectric withstand


kVp (@ sea level)

* Full ANSI
** ANSI without TD7

Schneider Electric SA 35 rue Joseph Monier 92500 Rueil Malmaison France Phone: +33 (0) 1 41 29 70 00 Fax: +33 (0) 1 41 29 71 00 www.schneider-electric.com
NRJED311015EN

NRJED311015EN.indd 3

Products-EOX-CB-EN 2011 Schneider Electric. All rights reserved.

EOX 15
15 /15.5 15 /15.5 1 5 /15.5 15 /15.5

03/2011

24/06/2011 11:41:37

Das könnte Ihnen auch gefallen