Sie sind auf Seite 1von 2

JET ENGINE SYSTEM-II

1.

2.

3.

4.

5.

6.

7.

8.

9.

In dual compressor turbine the starter drives the


a. Low Pressure turbine
b. high pressure turbine
c. Both A & B
d. As in A & with highest torque
Electronic motor starter are normally employed
with
a. 24 V series-wound
b. 24 V Shunt wound
c. 28 V series-wound
d. 28 V Shunt wound
_________ starter does not require engaging and
disengaging mechanism
a. Electric motor starter
b. Electric motor-generator starter
c. Air turbine Starter
d. Cartridge starter
MTCS Regarding Air Turbine Starter
a. Light weight to torque ratio
b. Require high volume of air
c. uses Compressed air from any source
d. All the above
______starters converts energy from compressed air
to shaft power
a. Air turbine Starter
b. Electric motor starter
c. Electric motor-generator starter
d. Cartridge starter
______ Starters operate by the means of high
pressure, high volume gas by burning the
propellant.
a. Hand crank Starter
b. Gas turbine starter
c. Air turbine Starter
d. Cartridge starter
______starter is a small gas turbine engine minus
compressor
a. Gas turbine starter
b. Cartridge starter
c. Fuel-Air Combustion Starter
d. Liquid monopropellant
________ starter has its own fuel, air, ignition
system
a. Gas turbine starter
b. Hydraulic starter
c. Cartridge starter
d. As in A and Fuel air combustion
starter
Gas turbine starter itself is started by
a. Electrically
b. Compressed air
c. Hydraulically
d. Either of the above
10.

11. The examples of energy limited starter is


a. Electric motor starter
b. Cartridge starter
c. Both A & B
d. As in c & Hydraulic starter

12. _______is the simplest of all starters


a. Gas turbine starter
b. Air turbine starter
c. Air impingement
d. Liquid monopropellant
13. _____starter only implies gear train to rotate the
engine
a. Electric motor starter
b. Electric motor-generator starter
c. Air turbine Starter
d. Hand crank starter
14. Engine does not rotate when the starter s/w is
closed in external power start; the probable cause
is
a. External power source faulty
b. Starter faulty
c. Battery faulty
d. All the above
15. The pobable cause of hung start is
a. Battery faulty
b. Starter faulty
c. Both A & B
16. In air turbine starter engine does not rotate to cut
off speed; the cause is APU or GPU faulty then what
is the remedy for it
a. Adjust setting
b. Repair or replace air unit
c. Replace starter
17. All of the aboveWhat is the function of a fire
detection system?
a. To discharge the power plant fire extinguishing
system at the origin of the fire.
b. To activate a warning device in the event
of a power plant fire.
c. To identify the location of a power plant fire.
18. In fire detection system, the Hot section alarms at
a. 100 degree c to 200 degree c
b. 200 degree c to 300 degree c
c. 300 degree c to 1200 degree C
d. .None
19. In fire detection system, the cold section alarms at
a. 100 degree c to 200 degree c
b. 200 degree c to 300 degree c
c. 300 degree c to 1200 degree c
d. None
20. In fire detection system, dimming relay is used to
a. reduce light in the circuit
b. reduce voltage in the circuit
c. reduce alarm in the circuit
d. reduce resistance in the circuit
21.
22.
23. _____is applied to circuit in fire detection system
a. 12V DC
b. b.24V DC
c. c.28V DC
d. d.25V DC
24. Short in a loop A is only detectable by
a. observing loop A
b. observing loop B
c. observing pooped reset button

Page 1 of 1

d. observing cockpit light


25. Open in the circuit is detected by
a. warning light
b. test switch
c. thermal spot detectors
d. none
26. Single wire fire detection system is also called
a. kidde system
b. fenwal system
c. Finwall system
d. all of the above
27. ________determines the alarm temperature of the
system in continuous loop.
a. inner materal
b. insulator material
c. dia. of wire used
d. distance between two wires
28. The relay coil is energized by
a. low current in circuit
b. high current in circuit
c. no current in circuit
d. none of the above
29. In Single wire fire detection system ______is used as
insulator
a. thermistor material
b. non thermistor material
c. eutectic salt
d. none
30. In Double wire fire detection system ______is used
as insulator
31. a.thermistor material
32. b.non thermistor material
33. c. eutectic salt
34. d. none
35. the heater probe is used to apply heat in
a. single wire system
b. double wire system
c. continuous loop system
d. pneumatic fire system
36. In pneumatic system, The tube contains_____ which
expands greatly when heated
a. hydraulic oil
b. inert gas
c. both
d. none
37. ____ is used in smoke detector
a. semi conductor
b. photo electric sensors
c. thermistor material
d. all of the above

38. If fire occurs on start up___ agent is used


a. CO2
b. methyl bromide
c. dry chemical powder
d. bromochlorodifluoromethane
39. _________is approved for aircraft fire
a. bromochlorodifluoromethane
b. bromotrifluoromethane
c. both
d. methyl bromide
40. ________is the oldest type extinguishing agent in
aviation
a. CO2
b. methyl bromide
c. dry chemical powder
d. bromochlorodifluoromethane
41. ____ is used to check the continuity of circuit in
continuous loop system
a. Test switch
b. Jetcal analyser
c. Dimming relay
d. All the above
42. In double wire system, if there is short in loop A
a. False fire indication
b. Behave normally
c. Both (a) and (b)
43. In single wire system, short in loop will cause
a. False fire indication
b. Behave normally
c. Both (a) and (b)
44. In single wire system, negative terminal is
grounded in
a. loop A
b. Loop B
c. Test switch
d. Thermal switch
45. In continuous loop single wire system, the outer
material is
a. Utectic salt
b. Thermistor insulator
c. Ceramic bead
d. All the above
46. Output voltage in high tension ignition system is
a. 10,000v
b. 20,000v
c. 3,000v to 10,000v
47. Position of igniter plug in ignition system is
a. 4 O clock & 8 O clock
b. 4 O clock & 7 O clock
c. 5 O clock & 7 O clock

Page 2 of 1

Das könnte Ihnen auch gefallen