Sie sind auf Seite 1von 45

H0FL-S01100SN

Standard ETH/E1 Converter


(E1/10/100Base-Tx)

H0FL-S01100SN

Standard ETH/E1 Converter


(E1/10/100Base-Tx)

Users Manual

Beijing Huahuan Electronics Co., Ltd.


Version 1.4 (Jan. 2016)

Copyright Notice
The intellectual property rights of all parts of this product,
including accessories etc., are owned by Beijing Huahuan Electronics
Co., Ltd. (Beijing Huahuan for short). Without prior written consent of
Beijing Huahuan, no part of this document may be reproduced or
transmitted in any form or by any means. The information in this
document, including product specifications and information, is subject
to change without notice. For information related, please consult
Beijing Huahuan.

Copyright Beijing Huahuan Electronics Co., Ltd. 2013 All rights


reserved

Product Name: H0FL-S01100SN Standard ETH/E1 Converter


Manual Version: 1.4
Release Date:

Jan.2016

BEIJING HUAHUAN ELECTRONICS Co., LTD.


Address: No.26, Shangdi 6th Street, Haidian District, Beijing, 100085
P.R. China
Tel: +86-400-810-8580, +86-10-52046188
Fax: +86-10-52046288
Web: http://www.huahuan.com
E-mail: support@huahuan.com

Contents
1.

OVERVIEW ........................................................... 1

1.1

Main features ................................................................. 1

1.2

Ordering Information ................................................... 2

2.

TYPICAL APPLICATION ...................................... 3

3.

STRUCTURE AND INSTRUCTION ....................... 4

3.1

Front and Rear Panels .................................................. 4

3.2

Bottom DIP Switches ................................................... 12

4.

CABLE INTRODUCTION .................................... 13

4.1

Ethernet Cable ............................................................. 13

4.2

E1 Cable (BH4.850.122) .............................................. 17

4.3

AC Power Cable........................................................... 18

4.4

DC Power Cable (ZJN.BH4.855.079)......................... 22

5.

INSTALLATION AND USAGE ............................ 23

5.1

Connect Ethernet Cable .............................................. 23

5.2

Connect E1 Cable ........................................................ 23

5.3

Connect Power Cord ................................................... 25

5.4

Post-installation Check................................................ 27

6.

DEVICE MONITORING ....................................... 30

6.1

NM Instruction ............................................................ 30

6.2 Query and Setting of IP Address, Subnet Mask,


Gateway and MAC Address ............................................................... 30
6.3

Device Monitoring ....................................................... 32

7.

TROUBLESHOOTING ........................................ 33

8.

MAIN TECHNICAL SPECIFICATIONS ............... 34

List of Figures
Figure 2-1 Typical application of H0FL-S01100SNpoint-to-point .................... 3
Figure 2-2 Typical application of H0FL-S01100SNpoint-to-multipoint ........... 3
Figure 3-1 Panel of H0FL-S01100SN (~220V AC, -48V DC or ~220V AC) ....... 4
Figure 3-2 Panel of H0FL-S01100SN (-48V DC) ................................................. 4
Figure 3-3 Panel of H0FL-S01100SN (+24V DC) ................................................ 4
Figure 3-4 RJ-48C connector ................................................................................. 7
Figure 3-5 Definition diagram of E1 loopback: LLB, RLB and R-RLB ............... 8
Figure 3-6 RJ-45 pin .............................................................................................. 9
Figure 3-7 4-position DIP switch on the bottom of H0FL-S01100SN................. 12
Figure 4-1 Ethernet cable appearance .................................................................. 13
Figure 4-2 Line order of the straight-through cable ............................................. 15
Figure 4-3 Line order of the 100 Mbit/s crossover cable ..................................... 16
Figure 4-4 RJ48-C socket cable (BH4.850.122) .................................................. 17
Figure 4-5 Chinese standard AC cable (ZJN.BH4.855.080) ................................ 19
Figure 4-6 South Africa standard AC cable (ZJN.BH4.855.080-D) .................... 20
Figure 4-7 German standard AC cable (ZJN.BH4.855.080-B) ............................ 20
Figure 4-8 North American AC cable (ZJN.BH4.855.080-G) ............................. 20
Figure 4-9 British standard AC cable (ZJN.BH4.855.080-F) .............................. 21
Figure 4-10 Japanese/American standard AC cable (ZJN.BH4.855.080-E) ........ 21
Figure 4-11 -48V DC power cable appearance .................................................... 22
Figure 5-1 Connect Ethernet electrical port ......................................................... 23
Figure 5-2 Connect RJ-48C socket cable (120) ................................................ 24
Figure 5-3 Connect interface conversion cable .................................................... 24
Figure 5-4 Connect RJ-48C socket cable (75) .................................................. 25

Figure 5-5 Connect 220V AC power cord ........................................................... 26


Figure 5-6 Connect 85~265VAC/36~72VDC power cord .................................. 26
Figure 5-7 Connect DC power cord ..................................................................... 27
Figure 6-1 Query and set things like IP address ................................................... 32

List of Tables
Table 1-1 Ordering information of H0FL-S01100SN ............................................ 2
Table 3-1 Labels and definitions of LEDs ............................................................. 5
Table 3-2 Definition of DIP switches .................................................................... 6
Table 3-3 Line definition of E1 port (RJ-48C) ...................................................... 7
Table 3-4 Ethernet port RJ-45 socket definition .................................................... 9
Table 3-5 Printings of bottom DIP switches of H0FL-S01100SNDIP
switches ........................................................................................................ 12
Table 4-1 Line orders of EIA/TIA 568A and EIA/TIA 568B standards .............. 14
Table 4-2 Technical specifications of Ethernet cable .......................................... 16
Table 4-3 Pin assignments of BH4.850.122 ......................................................... 17
Table 4-4 Technical specifications of BH4.850.122 ............................................ 18
Table 4-5 the corresponding table of AC power cable used in different regions . 19
Table 4-6 Technical parameters of AC power cable ............................................ 21
Table 4-7 Pin assignments of -48V DC power cable ........................................... 22
Table 5-1 Post-installation check items ............................................................... 27

Beijing Huahuan Electronics Co.,


Ltd.

1. Overview
H0FL-S01100SN is a standard network converter, realizing G.8040
compliant GFP encapsulation and de-capsulation of Ethernet frames for
transmission over an E1 channel.
With the increasing popularity of IP based applications, carriers wish to use
the rich legacy E1 resources to quickly set up broadband services for their
customers. H0FL-S01100SN is designed to meet this demand. Ethernet frames
are encapsulated into and de-capsulated from, E1 data stream transported over a
standard E1 channel. The converter is standard based, confirming to ITU-T
G.8040 and G.7043 recommendations, therefore it can interoperate with other
standard compliant Ethernet over E1 equipment from other manufacturers.

1.1 Main features

G.8040 compliant GFP encapsulation and de-capsulation of Ethernet frames;

Four 10/100Base-Tx Ethernet electrical switching ports, port 4 may be


configured as local management (NM) port;

Supports 802.1Q VLAN and port VLAN; supports input rate limit;

Supports MAC-address learning of up to 2048 table entries, and query of


the MAC address table;

The maximum Ethernet frame length is 2032byte;

Ethernet ports support 10/100M, full duplex, half duplex, as well as autonegotiation mode;

E1 port 75/120 impedance selectable, and complies with ITU-T G.703;

Supports E1 port loopback, error detection, loopback detection and removal,


BERT (Bit Error Rate Test);

Local clock or E1 line clock mode selectable;


H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co., Ltd.

Supports local Ethernet NM port, SNMP NM protocol, in-band and/or outof-band NM modes;

Supports querying Ethernet Rx/Tx bytes count, CPU and memory usage
rate through NMS;

Provides rich alarm indications;

Easy installation; no settings are needed when used for p2p application; and
compatible with H0FL-S01100 and H0FL-SF01100;

Interconnects with central office (CO) device H9MO-LMXE/GXS06 and


realizes remote monitoring;

Multiple power supply options: +24V DC, -48V DC, ~220V AC, -48V DC
or ~220V AC.

1.2 Ordering Information


Ordering information refers to the product types and configuration lists of
different types selected by users in the purchase of H0FL-S01100SN.
Table 1-1 lists ordering information of H0FL-S01100SN.
Table 1-1 Ordering information of H0FL-S01100SN

Product type
H0FL-S01100SN

Description
4 10/100M Ethernet electrical ports
1 E1 port
AC 220V power supply

H0FL-S01100SN/E

4 10/100M Ethernet electrical ports


1 E1 port
DC -48V or AC 220V dual-module power supply

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

2. Typical Application
H0FL-S01100SN can connect LANs in two different places. Because of the
distance, it is not feasible to use Ethernet line. And together with the high cost of
the dedicated Ethernet link, it is better to use the obtained E1 channels for
transportation, which only requires a pair of H0FL-S01100SN devices at each
end of E1 lines to realize the data access of the users conveniently and quickly
and enable Ethernet data to be transmitted in E1, as well as support SNMP
monitoring. H0FL-S01100SN can interwork with the corresponding card
S01100/SF01100 of central office CO device S01100/SF01100, but at this time
it does not support remote monitoring. It can also interconnect with CO device
H9MO-LMXE/GXS06 or standard Ethernet over E1 converter from other
makers.
Typical applications of H0FL-S01100SN are shown in Figure 2-1 and

Figure 2-2.

FE

LAN

E1

H0 FL-S01100SN

Transmission
network

FE

E1

H0FL-S01100SN

LAN

Or converter from other makers

Figure 2-1 Typical application of H0FL-S01100SNpoint-to-point

NM
N10 /100Base-Tx

E1
H9MOLMXE/GXS06

E1

H0FL-S 01100 SN

10/100Base- Tx

H0FL-S01100SN

10/100Base- Tx

.
.
.
.

CO

Figure 2-2 Typical application of H0FL-S01100SNpoint-to-multipoint


H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co., Ltd.

3. Structure and Instruction


3.1 Front and Rear Panels
Front and rear panels of H0FL-S01100SN are shown in Figure 3-1~Figure

3-3, providing E1 port, Ethernet ports, power switch and power input port (the
actual product appearance may differ because of the selected configuration):
H0FL-S01100SN
SYS
PWR
DATA1

DATA2

DATA3

DATA4/NM

E1

R-RLB/ TEST TMP_IP


MASK
L-RLB
LOOP
ERR
LOS/
AIS

85-265VAC/36-72VDC

L/+ PG N/-

Figure 3-1 Panel of H0FL-S01100SN (~220V AC, -48V DC or ~220V AC)

PWR
DATA1

DATA2

DATA3

DATA4/NM

E1

DC 48V

SYS

R-RLB/ TEST TMP_IP


MASK
L-RLB
LOOP
ERR
LOS/
AIS

H0FL-S01100SN

Figure 3-2 Panel of H0FL-S01100SN (-48V DC)

PWR
DATA1

DATA2

DATA3

DATA4/NM

E1

DC 24V

SYS

R-RLB/ TEST TMP_IP


MASK
L-RLB
LOOP
ERR
LOS/
AIS

H0FL-S01100SN

Figure 3-3 Panel of H0FL-S01100SN (+24V DC)

LED Instruction:
The labels and definitions of the LEDs on the rear panel are shown in Table
3-1.

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

Table 3-1 Labels and definitions of LEDs


Label

Color

Definition
Operation status indication:

Remark
-

On: normal power supply, the device is


SYS

Green

starting;
Flashing: the device is in operation;
Off: shutdown or power failure
Power indication:

PWR

Green

On: normal power supply;


Off: power failure
E1 loopback status indication:

LOOP

Yellow

On: E1 link is in loopback status;


Off: E1 link is in non-loopback status;
Flash: in error testing
Error alarm indication of E1 link:

ERR

Red

Flashing: bit error detected in E1 link;


Off: no bit error in E1 link
Status alarm indication of E1 port:

Solid on: no signal received at E1


port
LOS/AIS

Red

Slow flashing: all-ones signal received


at E1 port;
Randomly flashing: E1 code error;
Off: normal signal
Link and data flow indication of
Ethernet port:

L/A

Green

On: connection established;


Flashing: communication exists;
Off: no connection

FDX

Yellow

At Ethernet
RJ-45
socket

FDX indication of Ethernet port:

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co., Ltd.

On: full-duplex mode;


Off: half duplex mode;

DIP Switch Instruction:


The labels and definitions of the DIP switches of the device are shown in
Table 3-2. For the DIP switches here, ON means to turn down, OFF means
to turn up, for details, please refer to the marks on them.
Table 3-2 Definition of DIP switches
Number

Label

Definition
Turn down: set local E1 port outloop, i.e. RxTx

L-RLB

loopback;
Turn up: cancel the loopback
Turn down: set remote E1 port outloop, i.e. Rx

R-RLB/TEST

Tx loopback, which can perform E1 error test;


Turn up: cancel the loopback
Turn down: The IP address of the device returns to

TEMP-IP

MASK

the default value 192.192.192.192 temporarily;

Turn up: The IP address of the device is the userset IP


Turn down: set local alarm mask;
Turn up: cancel the current alarm mask

Note: in case the user forgets the devices IP address, turn down
TEMP_IP to make the device temporarily run at fixed IP address
(192.192.192.192), so as to query the devices actual address through Telnet
(the setting method will be introduced later). Five minutes after turning
down the switch, the device will return to the actual address regardless of
whether the user turn up the switch or not.
6

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

E1 Port:
E1 port of H0FL-S01100SN uses RJ-48C socket, whose signal definition is
given in Table 3-3 and whose impednce can be 75 or 120, which is selected
by the 4-position DIP switch on the bottom plate of the device. When DIP
switch 1-2 (ON) is turned up, it is 75; when turned down, 120.
Table 3-3 Line definition of E1 port (RJ-48C)
Pin
Definition

In+

In-

Shield

Shield

In

Impedance

Out+

Out- Shield -

120

Shield Shield

Out Shield -

75

For 120 connection, RJ-48C connector which is clamped with 120


twisted pair can be directly used, as shown in Figure 3-4. When making cables,
please ensure the input and output line pairs respectively use a twisted pair. For
75 connection, accessory cable ZJN. BH4.850.122 is needed to convert RJ48C to BNC socket.

1
8

Figure 3-4 RJ-48C connector


H0FL-S01100SN supports E1 lopback detection and elimination functions,
and the later is enabled by default. When E1 loopback elimination function is
enabled, when a loopback occurs in E1 channel, the link will be eliminated

automatically and Ethernet service will be interrupted. And when the


loopback is removed, the link will be recovered automatically too. E1
loopback elimination function can be disenabled by NMS, but the time of
disenabling is limited, which is 30min by default and can be configured to

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co., Ltd.

0~255min. The operation of disenabling loopback elimination function will not


be saved after power off.
H0FL-S01100SN supports maintenance tests like E1 loopback and BERT
though NMS and hardware DIP switches. E1 loopback supports local loopback
LLB (E1 of the local device is TxRx), remote loopback (E1 of the local device
is RxTx) and remote loopback Remote-RLB of the remote device (E1 of the
remote device is RxTx), please see their definition diagram in Figure 3-5.
ETH

Tx
Rx

Remote device
R-RLB

E1

.
.
.

LLB

Tx

Local device

Rx

RLB

Figure 3-5 Definition diagram of E1 loopback: LLB, RLB and R-RLB


When local loopback LLB is set, E1 of the local device is TxRx, and
cooperating with BERT error test function can check whether the local device is
normal or not. When remote loopback RLB is set, E1 of the local device is Rx
Tx, testing the local devices E1 port by an E1 error tester or testing DDF frame
of the remote end can check whether E1 transmission line is normal or not.
When remote loopback Remote-RLB of the remote device is set, E1 of the
remote device is controlled to RxTx, connecting an E1 error tester to the local
DDF frame can test whether E1 transmission line is normal or not.
BERT error test principle is to conduct error test by a simple built-in error
tester. BERT requires remote E1 loopback set through DIP switch R-RLB/TEST
or NMS. The error count and error rate detected in E1 link can be queried when
error test is conducted through NMS and the error testing result can be indicated
by panel LED ERR: if it is on, bit error detected in E1 link; if off, no bit error
detected in E1 link.

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

H0FL-S01100SN can choose the local clock (by default) or E1 line clock
though CO NMS. When the latter one is adopted, if E1 signal loss occurs, it will
switch to the local clock automatically, and when the line recovers, it will extract
clock from this E1. When the device is used for point-to-point application, a

master clock and a slave clock must be set, i.e. local clock at one end and E1
line clock at the other end must be set.
Note: When conducting E1 loopback test, the clock of the device must
be set to the local clock.

Ethernet Port
H0FL-S01100SN provides 4 Ethernet electrical ports externally, which are
standard RJ-45 twisted-pair ports. RJ-45 connector and its pin definition are
shown below.

1
8

Figure 3-6 RJ-45 pin


Table 3-4 Ethernet port RJ-45 socket definition
Pin

Definition

TxD+

TxD-

RxD+

RxD-

Note: Rx and Tx in the table above are defined based on this device.
At Ethernet socket, there are two LEDs, which are defined inTable 3-1.
The first 3 DATA ports (marked with DATA1-3) of H0FL-S01100SN are
10/100Base-Tx Ethernet switching ports, and they can divide VLAN to realize
port isolation; the 4th 10/100M adaptive Ethernet Electrical port (marked with
H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co., Ltd.

DATA4/NM) can be used as local NM port and Ethernet port under in-band
NM mode.
Ethernet of H0FL-S01100SN conforms to standards like ITU-T G.7043,
ITU-T G.8040, IEEE 802.3, IEEE 802.1Q and adopts standard GFP
encapsulation protocol. Ethernet electrical port supports auto-negotiation mode
and 10/100M, full/half duplex mode.
H0FL-S01100SN supports the transparent transmission of Ethernet data
and VLAN setting based on port or 802.1Q, and the range of VLAN ID is
1~4094.
H0FL-S01100SN supports LCAS function, which is enabled by default.
For single E1 converter, supporting LCAS function is for the interconnection
with devices that support LCAS function, for example, if H0FL-S01100SN is
interconnecting with CO H9MO-LMXE or GXS06, LCAS of them should be set
to the same.
Ethernet ports support rate limit function, and input rate limit can be set
through NMS. The supported rate limit is 64, 128, 256, 512, 1024 and
2048Kbit/s. There is no rate limit by default.
Ethernet port supports LFP (link fault pass-through) function based on E1
link, which is disabled by default and can be enabled through NMS. When LFP
function is enabled, connections of Ethernet ports (not including NM port) in the
link can be detected automatically, when an Ethernet port is disconnected or E1
link is interrupted, the Ethernet port of the link partner device with the same
sequence number will be forced to Link Down, so as to facilitate tracing network
connection failure.
H0FL-S01100SN supports MAC address learning function. MAC addresses
of data packets can be queried and up to 2048 table entries are supported.

10

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

H0FL-S01100SN supports querying Ethernet Rx/Tx bytes count , CPU and


memory usage rate through NMS.
Note: if H0FL-S01100SN is used for point-to-point connection, when
the sequence numbers of the Ethernet ports connected by the devices of the
two ends are different, please disable LFP function.
Note: Ethernet ports of H0FL-S01100SN can automatically detect the
transceiver line order of the connected network cable, so it can be used
whether the connected Ethernet interface is MDI or MDI-X, and whether
the network cable used is crossover or straight-through.

Power Port:
On the left side of the rear panel, there is a power input port. Power supply
type supports +24V DC, -48V DC, ~220V AC, -48V DC or ~220V AC. When
+24V DC and -48V DC power supply is used, DC 22 socket is provided; when
~220V AC, -48V DC or ~220V AC power supply is used, ~220V standard AC
power socket is provided. Users can select the power supply type as needed.

Note: The power connector on the device is AC-Only, DC-Only, or


Unified-AC/DC, depending on the power option purchased.
1.

For DC-Only version, use the color-coded wires on the open end of the
power cord for power connection. Red is for high potential, i.e. GND for 48V (or +24V); Blue is for low potential, i.e. -48V (or GND for +24V).
When inserting power plug, pay attention to direction of locking lever.
The electrode on the bottom left of DC socket is protection ground
connected to the yellow-green wire.

2.

For Unified-AC/DC version, only an AC power cord is supplied, which


should be used directly for AC power supply. In case of DC power supply,
cut off the wall plug on the cord, connect the brown wire to high potential
H0FL-S01100SN Converter Users Manual V1.4

11

Beijing Huahuan Electronics Co., Ltd.

(socket marked with L/+), i.e. GND for -48V; connect the light blue wire
to low potential (socket marked with N/-), i.e. -48V; connect yellow-green
wire to protection ground (socket marked with PG).
3.

For users safety, please make sure the protection ground is connected
well when installing the device.

3.2 Bottom DIP Switches


On the bottom of 1 H0FL-S01100SN, there is a 4-position DIP switch, for
setting E1 port impedance of the device, which is turned by default, i.e. E1
port impedance is 75, as shown in Figure 3-7.
75

DIP

ON

E1

120

Figure 3-7 4-position DIP switch on the bottom of H0FL-S01100SN

Bottom Printings:
The definition of DIP switches and the line definition of E1 port (RJ-48C
socket) are printed on the bottom of the device. For the line definition of E1 port
(RJ-48C socket), please refer to Table 3-3, as it will not be mentioned here.
Table 3-5 Printings of bottom DIP switches of H0FL-S01100SNDIP switches
1

2
E1

12

4
N/A

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

4. Cable Introduction
4.1 Ethernet Cable
Application
The Ethernet cable is used to connect the Ethernet electrical port to other
devices.
The Ethernet port on the H0FL-S01100SN is self-adaptive to straightthrough cable mode and crossover cable mode. Both of them can be used to
connect Ethernet electrical port.

Appearance
Figure 4-1 shows the Ethernet cable.

Connector 1

Connector 2

PIN 1 PIN 8

PIN 1 PIN 8

Figure 4-1 Ethernet cable appearance


Pin Assignments
Ethernet cables are classified into straight-through cables and crossover
cables:

Straight through cable: the line orders of twisted pair crimped by both
ends RJ45 connectors are EIA/TIA 568B standard line orders.

H0FL-S01100SN Converter Users Manual V1.4

13

Beijing Huahuan Electronics Co., Ltd.

Crossover cable: the line order of twisted pair crimped by one end
RJ45 connector is EIA/TIA 568A standard line order, the line order of
the other end is EIA/TIA 568B standard line order.

Line orders of EIA/TIA 568A and EIA/TIA 568B standards are shown in
Table 4-1.
Table 4-1 Line orders of EIA/TIA 568A and EIA/TIA 568B standards
Connector

EIA/TIA 568A

EIA/TIA 568B

(RJ45)
PIN 1

White/green

White/orange

PIN 2

Green

Orange

PIN 3

White/orange

White/green

PIN 4

Blue

Blue

PIN 5

White/blue

White/blue

PIN 6

Orange

Green

PIN 7

White/brown

White/brown

PIN 8

Brown

Brown

Both two RJ45 connectors of the straight through cable follow


EIA/TIA568B standard line order, as shown in Figure 4-2.

14

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.
Connector1 (EIA/TIA568B)

Connector2 (EIA/TIA568B)

PIN 1

White/orange

White/orange

PIN 1

PIN 2

Orange

Orange

PIN 2

PIN 3

White/green

White/green

PIN 3

PIN 4

Blue

Blue

PIN 4

PIN 5

White/blue

White/blue

PIN 5

PIN 6

Green

Green

PIN 6

White/brown

PIN 7

Brown

PIN 8

PIN 1
PIN 8

PIN 7 White/brown
PIN 8

Brown

Figure 4-2 Line order of the straight-through cable


RJ45 connectors on both ends of crossover cable need to use different
standard line orders, usually one RJ45 connector follows EIA/TIA568A standard;
the other RJ45 connector follows EIA/TIA568B standard.
The line order of the 100 Mbit/s crossover cable is shown in Figure 4-3.
Connector1 (EIA/TIA568A)

Connector2 (EIA/TIA568B)

PIN 1

White/green

White/orange

PIN 1

PIN 2

Green

Orange

PIN 2

PIN 3

White/orange

White/green

PIN 3

Blue

PIN 4

PIN 4 White/brown
PIN 5

Brown

White/blue

PIN 5

PIN 6

Orange

Green

PIN 6

PIN 7

Blue

White/brown

PIN 7

Brown

PIN 8

PIN 1
PIN 8

PIN 8

White/blue

H0FL-S01100SN Converter Users Manual V1.4

15

Beijing Huahuan Electronics Co., Ltd.

Figure 4-3 Line order of the 100 Mbit/s crossover cable


Technical Specifications
Technical specifications of Ethernet cable are shown in Table 4-2.
Table 4-2 Technical specifications of Ethernet cable
Item
Connector type
Cable type

Description
RJ45 connector (crystal head)
Category 5 unshielded twisted pair
(UTP-5) or shielded twisted pair (STP)

Color
Characteristic

Dark grey
100.0

impedance
Inner conductor

0.510mm

wire diameter
Breakdown voltage

500.0V

Inner conductor DC

93.8/km

impedance
Quantity of cores

Frequency range

0~100MHz

Frequency

22dB/100m@100MHz

attenuation

16

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

4.2

E1 Cable (BH4.850.122)

Application
E1 cable is used to connect E1 interface of equipment card, realizing

the transmission of E1 signal.


Appearance
RJ48-C socket cable (BH4.850.122) is composed by 1 RJ45 crystal head
and 2 BNC heads, whose appearance diagram is shown in Figure 4-4.
R

RJ45

Figure 4-4 RJ48-C socket cable (BH4.850.122)


Pin Assignments
Table 4-3
(BH4.850.122).

shows

pin

assignments

of

RJ48-C

socket

cable

Table 4-3 Pin assignments of BH4.850.122


RJ45 pin

BNC head

BNC_R shell/BNC_R shell

BNC_R core/BNC_R core

BNC_T shell/BNC_T shell

BNC_T core/BNC_T core

H0FL-S01100SN Converter Users Manual V1.4

17

Beijing Huahuan Electronics Co., Ltd.

RJ45 pin

BNC head

Technical Specifications
Table 4-4 shows technical specifications of RJ48-C socket cable
(BH4.850.122).
Table 4-4 Technical specifications of BH4.850.122
Item

4.3

Description

Cable name

RJ45 head/BNC adapter cable

Cable type

SYV75-2-1 (diameter: 2mm, coaxial cable)

Connector

RJ45 crystal head, BNC head

AC Power Cable

Application
AC power cable transports AC power from power distribution equipment to
AC power supply socket, and then transmits power to the entire device.
Appearance
AC power cable of H0FL-S01100SN depends on local standards, while
different regions have different standards, as shown in Table 4-5.

18

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

Table 4-5 the corresponding table of AC power cable used in different


regions
Regional standard

Cable type

Chinese standard

ZJN.BH4.855.080

British standard

ZJN.BH4.855.080-F

North American standard

ZJN.BH4.855.080-G

Japanese/American standard

ZJN.BH4.855.080-E

South Africa standard

ZJN.BH4.855.080-D

German standard

ZJN.BH4.855.080-B

The AC power cable (ZJN.BH4.855.080) which meets Chinese standard is


composed of Chinese standard three-plug connector and pins terminal, as shown
in Figure 4-5.

Figure 4-5 Chinese standard AC cable (ZJN.BH4.855.080)


The AC power cable (ZJN.BH4.855.080-D) which meets South Africa
standard is composed of South Africa standard three-plug connector and pins
terminal, as shown in Figure 4-6.

H0FL-S01100SN Converter Users Manual V1.4

19

Beijing Huahuan Electronics Co., Ltd.

Figure 4-6 South Africa standard AC cable (ZJN.BH4.855.080-D)


The AC power cable (ZJN.BH4.855.080-B) which meets German standard
is composed of German standard French-mode two-plug connector and pins
terminal, as shown in Figure 4-7.

Figure 4-7 German standard AC cable (ZJN.BH4.855.080-B)


The AC power cable (ZJN.BH4.855.080-G) which meets North American
standard is composed of North American standard three-plug connector and pins
terminal, as shown in Figure 4-8.

Figure 4-8 North American AC cable (ZJN.BH4.855.080-G)


The AC power cable (ZJN.BH4.855.080-F) which meets British standard is
composed of British standard three-plug connector and pins terminal, as shown
in Figure 4-9.

20

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

Figure 4-9 British standard AC cable (ZJN.BH4.855.080-F)


The

AC

power

cable

(ZJN.BH4.855.080-E)

which

meets

Japanese/American standard is composed of Japanese/American standard twoplug connector and pins terminal, as shown in Figure 4-10.

Figure 4-10 Japanese/American standard AC cable (ZJN.BH4.855.080-E)


Technical Parameters
Table 4-6 lists technical parameters of AC power cable.
Table 4-6 Technical parameters of AC power cable
Item
Cable type
Color
Inner conductor cable

Description
Electronic and electrical cable
Black
Cross-sectional area0.5mm2

standard
Length

1.5m

H0FL-S01100SN Converter Users Manual V1.4

21

Beijing Huahuan Electronics Co., Ltd.

4.4

DC Power Cable (ZJN.BH4.855.079)

Application
DC power cable transports DC power from power souring equipment to DC
power supply socket, and then transmits power to the entire device.
Appearance
DC power cable is composed of 2X2 socket and power cable, as shown in

Figure 4-11.
+

3
1

-48V GND

CGND

1m

-48V
2m

Figure 4-11 -48V DC power cable appearance


Pin Assignments
Table 4-7 lists pin assignments of -48V DC power cable.

Table 4-7 Pin assignments of -48V DC power cable


PIN

22

Color

Signal definition

Blue

-48V

Yellow-green

Red

-48V GND

CGND

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

5. Installation and Usage


5.1

Connect Ethernet Cable


Step1

Select proper cable length according to the cable path and then
make an Ethernet cable according to 4.1.

Step2

Aim one RJ45 connector of the Ethernet cable at the Ethernet


port of device; and then insert it into the port with moderate
force, as shown in Figure 5-1.

Figure 5-1 Connect Ethernet electrical port


Step3

Aim another RJ45 connector of the Ethernet cable at the remote


device Ethernet port, and then insert it into the port with
moderate force.

5.2

Connect E1 Cable

120 Impedance Port


Step1 Make an E1 cable according to the pin definition in Table 3-3.
Step2 Aim one crystal head of cable at the RJ-48C socket on devices
card; and then insert it into the socket with moderate force, as
shown in Figure 5-2.

H0FL-S01100SN Converter Users Manual V1.4

23

Beijing Huahuan Electronics Co., Ltd.

Figure 5-2 Connect RJ-48C socket cable (120)


Step3 Connect crystal head on the other side of the cable to users device.
75 Impedance Port
Step1 Convert RJ-48C socket into BNC socket by using BH4.850.122
interface conversion cable sent with the device.

R
T
R
T

Figure 5-3 Connect interface conversion cable


Step2 Aim the bayonet of BNC male interface at the standoff of interface
conversion cables BNC interface, and then insert it into the
standoff with moderate force and turn it right to the slot.

24

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

Figure 5-4 Connect RJ-48C socket cable (75)


Note:

On interface conversion cable BH4.850.122, BNC interface marked


with T is E1 signal output, while the one marked with R is E1
signal input. Be careful not to reverse input and output.

Users can choose the port impedance according to the actual


application, but 75 and 120 of the same E1 port cannot be used
at the same time.

5.3 Connect Power Cord


Step1 If you select 220V AC power supply, aim AC power connector at
~220V standard AC power socket on the device, and then insert it
into the socket with moderate force, as shown in Figure 5-5.

H0FL-S01100SN Converter Users Manual V1.4

25

Beijing Huahuan Electronics Co., Ltd.

Figure 5-5 Connect 220V AC power cord


Step2 If you select 85~265VAC/36~72VDC power supply, aim the
connector of DC power cord at the 85~265VAC/36~72VDC power
socket, and then insert it into the socket with moderate force, as
shown in Figure 5-6.

85-265VAC/36-72VDC

L /+

PG

N /-

Figure 5-6 Connect 85~265VAC/36~72VDC power cord


NoteFor Unified-AC/DC power supply, only an AC power
cord is supplied, which should be used directly for AC power
supply. In case of DC power supply, cut off the wall plug on the
cord, connect the brown wire to high potential, i.e. GND for -48V;
connect the light blue wire to low potential, i.e. -48V; connect
yellow-green wire to protection ground.

26

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

Step3 If you select -48V (or+24V) power supply, aim 22 connector of


DC power cord at the 22 socket of device, and then insert it into
the socket with moderate force, as shown in Figure 5-7.

+
1

Figure 5-7 Connect DC power cord


Note: For DC-Only power supply, use the color-coded wires
on the open end of the power cord for power connection. Red is for
high potential, i.e. GND for -48V (or +24V); Blue is for low
potential, i.e. -48V (or GND for +24V), yellow-green wire is
connected to protection ground.

5.4

Post-installation Check
Table 5-1 Post-installation check items
Number

Descriptions

Method

There are no other things placed on the chassis

Check

The screws must be secured correctly

Check

H0FL-S01100SN Converter Users Manual V1.4

27

Beijing Huahuan Electronics Co., Ltd.

Number
3

Descriptions
All the cables are bound with proper tightness.

Method
Check

The space between the cable ties is even, and


the remaining parts of the cable ties are cut off
neatly. All cable ties face the same direction,
keeping the overall appearance nice
4

Signal cables must be routed according to the

Check

engineering design
5

Signal cables should not be damaged or broken,

Check

and there should not be any joints on the cable


6

The connectors of the signal cable must be neat

Check

and intact. The connectors must be connected


correctly and firmly. The tips of the connectors
must be connected securely
7

Signal cables must be laid horizontally or

Check

vertically without crossing, and must be


bundled moderately at the turning (crossing is
allowed for cables within 1m outside the
cabinet)
8

Labels at both ends of the signal cable must be

Check

marked correctly, clearly and neatly


9

The routing of power cables and ground cables


must comply with the engineering design. This
helps maintenance and expansion

28

H0FL-S01100SN Converter Users Manual V1.4

Check

Beijing Huahuan Electronics Co.,


Ltd.

Number
10

Descriptions
The power cable and ground cable must use an

Method
Check

entire segment of copper core. The cable should


have no connection in the middle or scratch on
the skin
11

The power cables and ground cables must be

Check

corrected correctly and reliably


12

The cross-sectional area of the power cable and

Check

ground cable must comply with the engineering


design, meeting the requirements of running the
equipment
13

The power cables, ground cables and signal

Check

cables must be routed separately


14

The power cables and ground cables must be

Check

routed horizontally and vertically without


crossover. Proper margins must be reserved at
the turning
15

The identifiers on things like the power cable

Check

and ground cable must be correct, legible and


neat
16

The optical fibers routed outside the cabinet

Check

must be protected in a corrugated pipe and


cabling trough, and must be protected from
being extruded by other cables and goods

H0FL-S01100SN Converter Users Manual V1.4

29

Beijing Huahuan Electronics Co., Ltd.

6. Device Monitoring
The default IP address of H0FL-S01100SN is 192.192.4.2. During actual
networking, IP addresses must be assigned to the device at each end first. In the
network, the IP address of each node must be unique.

6.1

NM Instruction
H0FL-S01100SN supports two NM modes: out-of-band NM and in-band

NM, which can be set through NMS. When setting out-of-band NM, the 4th
Ethernet port (marked with DATA4/NM) is fixed as out-of-band NM port. Inband NM mode means that E1 transmits Ethernet service and monitoring
information at the same time. When setting in-band NM, NM port can be any
Ethernet port of the device, therefore the 4th Ethernet port can also be used as
service port. But to ensure the smoothness of NM channel effectively, it is
recommended to use the 4th Ethernet port as NM port. When dividing VLAN,
the tag attribute of the 4th Ethernet port fixes to untag, and cannot be set to tag.

6.2

Query and Setting of IP Address, Subnet Mask,


Gateway and MAC Address
H0FL-S01100SN requires logging Telnet to query and set the IP address

through Ethernet NM port. If the factory IP address is modified and the current
address is forgotten, you can turn down DIP switch TEMP-IP to make the device
running at a fixed IP (192.192.192.192), so as to query the devices actual
address through Telnet, and the host address mask needs to be modified to
255.255.255.0. Five minutes after turning down the switch, the device will
return to the actual address regardless of whether the user turn up the switch or
not.
The devices IP address, subnet mask, gateway and MAC address can be
modified through NMS or Telnet command. Detailed descriptions of modifying
30

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

through NMS can be found in online help of NMS. Telnet command can be
modified through the following methods.
Log in Telnet. Both the user name and the password are root in lower
case. Under the path usr/app/tools or usr/application/tools, executing ipconfig
can query the devices type, program version, IP address, subnet mask, gateway,
MAC address and etc.; executing set_addr can set the devices IP address,
subnet mask, gateway, MAC address and etc.; and executing tools can perform
things like online update of programs. Details are shown in Figure 6-1:

H0FL-S01100SN Converter Users Manual V1.4

31

Beijing Huahuan Electronics Co., Ltd.

Figure 6-1 Query and set things like IP address


Tip:
1. When use Set_addr to set IP address, subnet mask, gateway and MAC
address, multiple parameters can be set simultaneously, and the order is not
definite. After the setting is completed, it needs to restart the device by
powering off or logging in Telnet to use reboot command, only then will the
modified parameters become effective.
2. The factory default MAC address of the device is unique. Please do not
modify it.

6.3

Device Monitoring
H0FL-S01100SN supports SNMP NM protocol, after connecting its NM

port and setting SNMP monitoring management (SNMP Read Community:


public, SNMP Write Community: private) on the NMS, the local device can be
32

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

monitored, and after establishing Socket link, the remote device can be
monitored too.
H0FL-S01100SN supports NE auto-discovery function. For a detailed
introduction of the NM monitoring software of the device, please refer to online
help.

7. Troubleshooting
When fault occurs, first find out the position of alarm through the alarm
indication on the devices front panel (whether it is device fault, or transmission
line fault), and then deal with it accordingly. The following part is an instruction
of the judgment of common faults and solution measures.

Phenomenon

Possible causes
Power

PWR
is off

E1 port
alarm

Ethernet port
L/A
Green LED
is off
Ethernet
service is

supply

does

Solutions
not

meet

Replace Power Supply

requirements

Loose power wiring

Tighten the power wring

Loose RJ-48C wiring

Adjust the connector

Disconnected E1 cable, cable


Check E1 cable
fault, or wrong line order
Remote device fault
Replace it
Disconnected network cable, cable
Check the network cable
fault, or wrong line order
Change the electrical port
The configuration of electrical port
configuration of the device
does not comply with the link
or the link partner to ensure
partner devices
consistency
The VLAN of one end is set while Change VLAN settings to
the other is not; the devices of the make both the devices
H0FL-S01100SN Converter Users Manual V1.4

33

Beijing Huahuan Electronics Co., Ltd.

blocked

two ends are not in a VLAN group

disable VLAN or in a
VLAN group
After enabling LFP, the

After enabling LFP, the sequence

sequence numbers of the

numbers of the Ethernet ports that

Ethernet ports that connect

connect

the

the

two

devices

are

different

two

devices

must

correspond to each other


one by one

If problem occurs during installation or usage, please deal with it through


the above measures. If problem persists, please contact Beijing Huahuan
Electronics Co., Ltd. for technical support.

8. Main Technical Specifications


E1 Port:

Meet ITU-T G.703


Code pattern: HDB3
Bit rate: 2048kbit/s 50ppm
Impedance: optional 75/120
Connector: RJ-48C
Number: 1

ETH Port:

Meet ITU-T G.7043, ITU-T G.8040, IEEE 802.3, IEEE


802.1Q, and etc.
Electrical port Auto-negotiation or 10/100M half/full
duplex mode
Connector: RJ-45
Number: 4

Power Voltage:
34

DC+24V (+18V~+36V)

H0FL-S01100SN Converter Users Manual V1.4

Beijing Huahuan Electronics Co.,


Ltd.

DC-48V (-36V~ -72V)


AC~220V (85V ~ 265V, 50 ~ 60Hz)
Consumption:

5.5W

Environment:

Temperature: -545
Humidity: 90 (non-condensing)

Dimensions:

WHD (mm): 19535140

Weight:

0.7kg

H0FL-S01100SN Converter Users Manual V1.4