Sie sind auf Seite 1von 1

PTFE Single core: BS 3G 210 Type B 600V/190oC

B-E xxxx Application:


Equipment wire

Equipment wire
B-E xxxx NPC PTFE is Habia Cable’s foremost insulation material, intended for use up to 260oC. PTFE has excellent
mechanical properties, including solder resistance and offers unparalleled electrical performance. Typical
applications for PTFE include gas ignition wires, gas turbines, vacuum applications and high temperature
600/1000V data cables. Cores are designed according to BS 3G 210 Type B.
-75oC to +190oC (SPC)
-75oC to +260oC (NPC) Wire construction:
Conductor: B-E xxxx: Silver Plated Copper (SPC)
Flame Retardant
B-E xxxx NPC: Nickel Plated Copper (NPC)
Low Smoke Generation Insulation: Ram-extruded or wrapped & sintered PTFE insulation
BS 3G 210 Type B
Def Stan 61-12 Part 8
RoHS Compliant

Available colours: 00 11 22 33 44 55 66 77 88 99 29 89 45
Replace ‘cc’ in the order reference with resistor colour code
(e.g. B-E 3207 Black = 536003207) Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Natural Yw/Gn

Description Size Conductor Finished Wire Amps Order Reference


weight at 40oC prefix colour /
AWG mm 2
stranding wire Ø core Ø tolerance size
(kg/km) SPC NPC SPC NPC
B-E 3207 ... 32 0,04 7 x 0,08 0,24 0,74 +0,10 -0,09 1,44 3 4 537 tbc cc3207
B-E 3007 ... 30 0,06 7 x 0,10 0,30 0,80 ±0,10 1,75 4 5 537 tbc cc3007
B-E 2807 ... 28 0,08 7 x 0,12 0,36 0,88 +0,08 -0,12 2,10 6 7 537 tbc cc2807
B-E 2601 ... 26 0,13 1 x 0,40 0,40 0,90 ±0,10 2,56 8 9 537 tbc cc2601
B-E 2607 ... 26 0,13 7 x 0,15 0,45 0,95 ±0,10 2,74 8 9 537 tbc cc2607
B-E 2619 ... 26 0,15 19 x 0,10 0,50 1,00 ±0,10 3,09 8 9 537 tbc cc2619
B-E 2407 ... 24 0,20 7 x 0,20 0,60 1,10 ±0,10 3,95 11 12 537 tbc cc2407
B-E 2419 ... 24 0,21 19 x 0,12 0,60 1,10 ±0,10 3,89 11 12 537 tbc cc2419
B-E 2301 ... 23 0,28 1 x 0,60 0,60 1,10 ±0,10 4,38 11 12 537 tbc cc2301
B-E 2219 ... 22 0,34 19 x 0,15 0,75 1,25 ±0,10 5,44 14 16 537 tbc cc2219
B-E 2019 ... 20 0,60 19 x 0,20 1,00 1,50 ±0,10 8,43 19 22 537 tbc cc2019
B-E 1819 ... 18 0,93 19 x 0,25 1,25 1,75 ±0,10 12,11 27 30 537 tbc cc1819

De-rating factors for current rating


B-E xxxx 20 40 60 80 100 120 140 160 180 - - - - -
Temperature de-rating (oC) 1.08 1.00 0.92 0.84 0.75 0.65 0.55 0.42 0.28 - - - - -
B-E xxxx NPC 20 40 60 80 100 120 140 160 180 200 220 240 - -
Temperature de-rating (oC) 1.06 1.00 0.94 0.88 0.80 0.76 0.69 0.61 0.54 0.45 0.35 0.23 - -
2 3 4 6 8 10 12 16 20 24 28 32 36 40
Multicore de-rating factor
1.00 0.88 0.80 0.69 0.62 0.59 0.55 0.51 0.48 0.43 0.41 0.39 0.38 0.36
Note: All dimensions in mm and ±4% unless stated Date: 2010-04-30 Created: CJV Approved: TN Reference: EQ_BE_10
Data provided indicates nominal values unless stated otherwise and is only valid for reference purposes at the time of publication and is subject to change without prior notice.

32 world class cable solutions www.habia.com