Air System Sizing Summary for Default System

Project Name: Question 1


Prepared by: Rouzbeh

01-19-2017
12:51AM

Air System Information


Air System Name
Equipment Class
Air System Type

Default System
TERM
PKG-FC

Number of zones
Floor Area
Location

1
250000.0 ft
Edmonton, Alberta

Sizing Calculation Information


Calculation Months
Sizing Data

Hourly Analysis Program v4.90

Jan to Dec
Calculated

Zone CFM Sizing


Space CFM Sizing

Sum of space airflow rates


Individual peak space loads

Page 1 of 9

Zone Sizing Summary for Default System


Project Name: Question 1
Prepared by: Rouzbeh

01-19-2017
12:51AM

Air System Information


Air System Name
Equipment Class
Air System Type

Default System
TERM
PKG-FC

1
250000.0 ft
Edmonton, Alberta

Number of zones
Floor Area
Location

Sizing Calculation Information


Calculation Months
Sizing Data

Zone CFM Sizing


Space CFM Sizing

Jan to Dec
Calculated

Sum of space airflow rates


Individual peak space loads

Zone Sizing Data

Zone Name
Zone 1

Maximum
Cooling
Sensible
(MBH)
2750.9

Design
Airflow
(CFM)
163355

Minimum
Airflow
(CFM)
163355

Total
Coil
Load
(MBH)
2967.2

Sens
Coil
Load
(MBH)
2714.3

Coil
Entering
DB / WB
(F)
76.1 / 64.4

Time of
Peak Load
Jul 1800

Maximum
Heating
Load
(MBH)
1312.5

Zone
Floor
Area
(ft)
250000.0

Zone
CFM/ft
0.65

Terminal Unit Sizing Data - Cooling

Zone Name
Zone 1

Coil
Leaving
DB / WB
(F)
59.4 / 58.2

Water
Flow
@ 10.0 F
(gpm)
-

Fan
Design
Airflow
(CFM)
163355

Fan
Motor
(BHP)
0.000

Time
of
Peak
Load
Jul 1600

Terminal Unit Sizing Data - Heating, Fan, Ventilation

Zone Name
Zone 1

Heating
Coil
Load
(MBH)
1284.4

Heating
Coil
Ent/Lvg
DB
(F)
69.5 / 77.5

Htg Coil
Water
Flow
@20.0 F
(gpm)
-

Fan
Motor
(kW)
0.000

OA Vent
Design
Airflow
(CFM)
0

Space Loads and Airflows


Zone Name /
Space Name
Zone 1
Default Space

Hourly Analysis Program v4.90

Mult.

Cooling
Sensible
(MBH)

Time
of
Load

Air
Flow
(CFM)

Heating
Load
(MBH)

Floor
Area
(ft)

Space
CFM/ft

2750.9

Jul 1800

163355

1312.5

250000.0

0.65

Page 2 of 9

Hourly Analysis Program v4.90

Zone Name / Space Name


Zone 1
Default Space
Totals (incl. Space Multipliers)

2. Space Ventilation Analysis Table

Ventilation Sizing Method

1. Summary

Project Name: Question 1


Prepared by: Rouzbeh

Floor
Area
(ft)
250000.0

Mult.
1

1250.0

Maximum
Occupants
163355.3
163355.3

0.00

Maximum
Required
Supply Air Outdoor Air
(CFM) (CFM/person)

Sum of Space OA Airflows

0.00

Required
Outdoor Air
(CFM/ft)
0.0

0.0

Required
Required
Outdoor Air Outdoor Air
(CFM) (% of supply)

Ventilation Sizing Summary for Default System

0.0
0.0

Uncorrected
Outdoor Air
(CFM)

Page 3 of 9

01-19-2017
12:51AM

Air System Design Load Summary for Default System


Project Name: Question 1
Prepared by: Rouzbeh

ZONE LOADS
Window & Skylight Solar Loads
Wall Transmission
Roof Transmission
Window Transmission
Skylight Transmission
Door Loads
Floor Transmission
Partitions
Ceiling
Overhead Lighting
Task Lighting
Electric Equipment
People
Infiltration
Miscellaneous
Safety Factor
>> Total Zone Loads
Zone Conditioning
Plenum Wall Load
Plenum Roof Load
Plenum Lighting Load
Exhaust Fan Load
Ventilation Load
Ventilation Fan Load
Space Fan Coil Fans
Duct Heat Gain / Loss
>> Total System Loads
Terminal Unit Cooling
Terminal Unit Heating
>> Total Conditioning
Key:

Hourly Analysis Program v4.90

01-19-2017
12:51AM

DESIGN COOLING
DESIGN HEATING
COOLING DATA AT Jul 1600
HEATING DATA AT DES HTG
COOLING OA DB / WB 82.5 F / 66.5 F
HEATING OA DB / WB -25.0 F / -25.0 F
Sensible
Latent
Sensible
Latent
Details
(BTU/hr)
(BTU/hr)
Details
(BTU/hr)
(BTU/hr)
0 ft
0
0 ft
32000 ft
37786
32000 ft
200659
250000 ft
479822
250000 ft
1111885
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
500000 W
1705970
0
0
0W
0
0
0
50000 W
170599
0
0
1250
312496
250000
0
0
0
0
0
0
0
0
0
0
0
0% / 0%
0
0
0%
0
0
2706673
250000
1312545
0
2714332
250000
1284441
0
0%
0
0
0
0%
0
0
0
0%
0
0
0
0 CFM
0
0 CFM
0
0 CFM
0
0
0 CFM
0
0
0 CFM
0
0 CFM
0
0
0
0%
0
0%
0
2714332
250000
1284441
0
2714332
252854
0
0
0
1284441
2714332
252854
1284441
0
Positive values are clg loads
Positive values are htg loads
Negative values are htg loads
Negative values are clg loads

Page 4 of 9

Zone Design Load Summary for Default System


Project Name: Question 1
Prepared by: Rouzbeh

Zone 1

ZONE LOADS
Window & Skylight Solar Loads
Wall Transmission
Roof Transmission
Window Transmission
Skylight Transmission
Door Loads
Floor Transmission
Partitions
Ceiling
Overhead Lighting
Task Lighting
Electric Equipment
People
Infiltration
Miscellaneous
Safety Factor
>> Total Zone Loads

Hourly Analysis Program v4.90

01-19-2017
12:51AM

DESIGN COOLING
DESIGN HEATING
COOLING DATA AT Jul 1800
HEATING DATA AT DES HTG
COOLING OA DB / WB 78.6 F / 65.3 F
HEATING OA DB / WB -25.0 F / -25.0 F
OCCUPIED T-STAT 75.0 F
OCCUPIED T-STAT 70.0 F
Sensible
Latent
Sensible
Latent
Details
(BTU/hr)
(BTU/hr)
Details
(BTU/hr)
(BTU/hr)
0 ft
0
0 ft
32000 ft
44471
32000 ft
200659
250000 ft
517342
250000 ft
1111885
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
500000 W
1705974
0
0
0W
0
0
0
50000 W
170599
0
0
1250
312497
250000
0
0
0
0
0
0
0
0
0
0
0
0% / 0%
0
0
0%
0
0
2750883
250000
1312545
0

Page 5 of 9

Space Design Load Summary for Default System


Project Name: Question 1
Prepared by: Rouzbeh

TABLE 1.1.A.

SPACE LOADS
Window & Skylight Solar Loads
Wall Transmission
Roof Transmission
Window Transmission
Skylight Transmission
Door Loads
Floor Transmission
Partitions
Ceiling
Overhead Lighting
Task Lighting
Electric Equipment
People
Infiltration
Miscellaneous
Safety Factor
>> Total Zone Loads

TABLE 1.1.B.

N EXPOSURE
WALL
E EXPOSURE
WALL
S EXPOSURE
WALL
W EXPOSURE
WALL
H EXPOSURE
ROOF

Hourly Analysis Program v4.90

01-19-2017
12:51AM

COMPONENT LOADS FOR SPACE '' Default Space '' IN ZONE '' Zone 1 ''
DESIGN COOLING
DESIGN HEATING
COOLING DATA AT Jul 1800
HEATING DATA AT DES HTG
COOLING OA DB / WB 78.6 F / 65.3 F
HEATING OA DB / WB -25.0 F / -25.0 F
OCCUPIED T-STAT 75.0 F
OCCUPIED T-STAT 70.0 F
Sensible
Latent
Sensible
Latent
Details
(BTU/hr)
(BTU/hr)
Details
(BTU/hr)
(BTU/hr)
0 ft
0
0 ft
32000 ft
44471
32000 ft
200659
250000 ft
517342
250000 ft
1111885
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
500000 W
1705974
0
0
0W
0
0
0
50000 W
170599
0
0
1250
312497
250000
0
0
0
0
0
0
0
0
0
0
0
0% / 0%
0
0
0%
0
0
2750883
250000
1312545
0

ENVELOPE LOADS FOR SPACE '' Default Space '' IN ZONE '' Zone 1 ''
COOLING
COOLING
Area
U-Value
Shade
TRANS
SOLAR
(ft) (BTU/(hr-ft-F))
Coeff.
(BTU/hr)
(BTU/hr)

HEATING
TRANS
(BTU/hr)

8000

0.066

4152

50165

8000

0.066

12235

50165

8000

0.066

14636

50165

8000

0.066

13448

50165

250000

0.047

517342

1111885

Page 6 of 9

System Psychrometrics for Default System


Project Name: Question 1
Prepared by: Rouzbeh

01-19-2017
12:51AM

July DESIGN COOLING DAY, 1600


TABLE 1:

SYSTEM DATA

Component
Ventilation Air
Vent - Return Mixing
Ventilation Fan
Zone Air
Return Plenum

Location
Inlet
Outlet
Outlet
Outlet

Dry-Bulb
Temp
(F)
82.5
0.0
0.0
76.1
0.0

Specific
Humidity
(lb/lb)
0.01150
0.00000
0.00000
0.01139
0.01139

Airflow
(CFM)
0
0
0
163355
163355

CO2 Level
(ppm)
400
0
0
92
92

Sensible
Heat
(BTU/hr)
0
0
2714332
0

Latent
Heat
(BTU/hr)
0
250000
-

Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 0.991 BTU/(hr-CFM-F)
Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4353.6 BTU/(hr-CFM)
Site Altitude = 2372.0 ft

TABLE 2:

ZONE DATA

Component
Zone 1 ( Cooling )
Ventilation Air
Cooling Coil Inlet
Cooling Coil Outlet
Heating Coil Inlet
Heating Coil Outlet
Zone Air

Hourly Analysis Program v4.90

Location

Dry-Bulb
Temp
(F)

Specific
Humidity
(lb/lb)

Airflow
(CFM)

CO2 Level
(ppm)

Sensible
Heat
(BTU/hr)

Latent
Heat
(BTU/hr)

76.1
59.4
59.4
59.4
76.1

0.01139
0.01104
0.01104
0.01104
0.01139

0
163355
163355
163355
163355
163355

0
0
0
0
0

2714332
0
2714332

252854
-

Page 7 of 9

System Psychrometrics for Default System


Project Name: Question 1
Prepared by: Rouzbeh

01-19-2017
12:51AM

WINTER DESIGN HEATING


TABLE 1:

SYSTEM DATA

Component
Ventilation Air
Vent - Return Mixing
Ventilation Fan
Zone Air
Return Plenum

Location
Inlet
Outlet
Outlet
Outlet

Dry-Bulb
Temp
(F)
-25.0
0.0
0.0
69.5
0.0

Specific
Humidity
(lb/lb)
0.00022
0.00000
0.00000
0.01471
0.01471

Airflow
(CFM)
0
0
0
163355
163355

CO2 Level
(ppm)
400
0
0
0
0

Sensible
Heat
(BTU/hr)
0
0
-1284441
0

Latent
Heat
(BTU/hr)
0
0
-

Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 0.991 BTU/(hr-CFM-F)
Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4353.6 BTU/(hr-CFM)
Site Altitude = 2372.0 ft

TABLE 2:

ZONE DATA

Component
Zone 1 ( Heating )
Ventilation Air
Cooling Coil Inlet
Cooling Coil Outlet
Heating Coil Inlet
Heating Coil Outlet
Zone Air

Hourly Analysis Program v4.90

Location

Dry-Bulb
Temp
(F)

Specific
Humidity
(lb/lb)

Airflow
(CFM)

CO2 Level
(ppm)

Sensible
Heat
(BTU/hr)

Latent
Heat
(BTU/hr)

69.5
69.5
69.5
77.5
69.5

0.01471
0.01471
0.01471
0.01471
0.01471

0
163355
163355
163355
163355
163355

0
0
0
0
0

0
1284441
-1284441

0
-

Page 8 of 9

Psychrometric Analysis for Default System

Hourly Analysis Program v4.90

The psychrometric graph cannot be generated for this type of system.

Project Name: Question 1


Prepared by: Rouzbeh

Page 9 of 9

01-19-2017
12:51AM

Das könnte Ihnen auch gefallen