Beruflich Dokumente
Kultur Dokumente
PRODUCT DATA
Urethane
Prepolymers
Hygiene
Although ADIPRENE LFP 3940A has a very low level of free PPDI
monomer, this does not eliminate the need to manage health and safety
issues responsibly when handling this product. Impervious gloves and
goggles should be worn. Avoid contact with eyes, skin, and clothing, and
wash thoroughly after handling. Avoid breathing vapor. Use only with
adequate ventilation. In the absence of good ventilation or under
emergency situations, self-contained or air-supplied respiratory protection
is recommended. Before use consult MSDS for ADIPRENE LFP 3940A
for additional information on potential hazards and handling precautions.
Typical Properties
Viscosity, Centipoise (Pas)
@ 86F (30C) .................................................................(Solidifies)
@ 140F (60C) ...............................................................(Solidifies)
@ 176F (80C) ...............................................................6000 (60)
@ 212F (100C) .............................................................2500 (25)
HQEE
Notes:
1. Chemtura VIBRACURE A 250 is specially formulated for PPDI prepolymers to improve
mixing of prepolymer and curative during processing.
2. For best results, the mold should be pre-heated to the recommended temperature. If
the mold cools during handling and casting, it is desirable to preheat it enough above
the cure temperature to allow for its cooling.
3. Allow cast parts to condition for four weeks at room temperature before use.
Vibracure A 250
HQEE
All materials tested after conditioning at room temperature for four weeks.
Property values reported in this bulletin are for the specific composition shown. Additional colorants or
additives of any kind may alter some or all of the properties. The data listed fall within the normal range
of product properties, but they should not be used to establish specification limits nor used alone as the
basis of design.
Disclaimer
Except as otherwise provided by law outside the USA, the following information should be noted.
The information set forth herein is furnished free of charge and is based on technical data that Chemtura
believes to be reliable. It is intended for use by persons having technical skill, at their own discretion and
risk. The handling precaution information contained herein is given with the understanding that those
using it will satisfy themselves that their particular conditions of use present no health or safety hazards.
Since conditions of product use are outside our control, we make no warranties, express or implied, and
assume no liability in connection with any use of this information. Nothing herein is to be taken as a
license to operate under or a recommendation to infringe any patents.
Rev. ZZ/ROR:mc\4/99:1/02/02/jbk:11/02dd:6/04jh:7/05dd:ZZ/pl4/06: