Beruflich Dokumente
Kultur Dokumente
qxd
09.2.26 2:35 PM
Page 1
RoHS
compliant
Power saving
Standard: 0.4 W
Series VQ1000/2000
CAT.ES11-100A
VQ-A.qxd
09.2.26 2:36 PM
Page 2
Space-saving profile
All pilot valves are compactly mounted on one side.
The space-saving design of mounting all fittings on
one side permits mounting in three directions.
Flow-rate characteristics
Model
Manifold
pitch
(mm)
Metal seal
Rubber seal
C [dm3/(sbar)]
C [dm3/(sbar)]
Applicable
cylinder
bore size
VQ1000
10.5
0.72
1.0
Up to 50
VQ2000
16
2.6
3.2
Up to 80
Blanking plate
assembly
U sid
OFF
Port plug
ON
D sid
B side
Manual override
(Green)
A side
Manual override
(Orange)
DIN rail
Elbow fitting assembly
bottom ported
VQ1000
VQ1000
Plug-in
Base Mounted
Series
P. 7
Series
VQ2000
(F/L
kit
only)
Rubber seal
VQ101
P. 15
VQ200
2.6
2.0
3.2
2.2
(F/L
kit
only)
Rubber seal
VQ201
P. 15
50/60 50/60
Hz Hz
Manual override
0.65
Electrical entry
1.0
Voltage
Grommet
0.72
Metal seal
P. 11
VQ100
Pressure center
3-position
(Closed center)
0.72
Metal seal
Exhaust center
Double
Single
4/2 5/3
(A/B R1/R2)
Closed center
C [dm /(sbar)]
Type of actuation
Double
Single
Sonic
conductance
Plug-in
Valve Specifications
VQ-A.qxd
09.2.26 2:36 PM
Page 3
Series VQ1000
Series VQ2000
P kit
(Flat ribbon cable)
kit
(D-sub connector)
Number of pins: 15/25
Top entry
Side entry
G kit
(Flat ribbon
cable with
terminal block)
Number of pins: 20
Top entry
kit
(Terminal block
box)
Side entry
kit
(Lead wire)
kit
(PC Wiring System compliant
Flat ribbon cable)
Number of pins: 20
Top entry
S kit
(Serial
Side entry
M kit
(Circular
transmission)
connector)
(VQ2000 only)
Model
A side
B side
VQ1A01
VQ2A01
VQ1B01
VQ2B01
VQ1A01
VQ2A01
N.C.
valve
N.C.
valve
VQ1B01
VQ2B01
N.O.
valve
N.O.
valve
2
(B)
1
(P)
N.C.
valve
N.O.
valve
5
(R1)
3
(R2)
2
(B)
1
(P)
3
(R2)
Ejector unit
Regulator unit
Built-in silencer
Name plate
Options
Blanking plate
P. 55
5
(R1)
3
(R2)
Except
L kit
P. 55
Except
S/G
kit
1
(P)
4
(A)
VQ1C01
VQ2C01
Semi-standard
Except
S/G
kit
5
(R1)
2
(B)
4
(A)
R1 A P B R2
External pilot
JIS symbol
4
(A)
P. 65
Except
L kit
P. 71
VQ-A.qxd
09.2.26 2:36 PM
Page 4
Series VQ /Base
Mounted: Variations
Manifold Variations
Plug-in
Series VQ1000
F
kit
P
kit
J
kit
G
kit
T
kit
Series VQ2000
D-sub connector
Conforming to with MIL
D-sub connector
P. 17
P. 17
P. 21
P. 21
P. 29
P. 29
Terminal block
box
(Terminal block)
Terminal block is
compactly arranged on
one side.
P. 33
IP65 enclosure
compatible
P. 33
P. 37
IP65 enclosure
compatible
P. 37
Lead wire
Direct electrical entry type
3
4
kit
1
2
4
3
2
3
2
1
VQ-A.qxd
09.2.26 2:36 PM
Page 5
Manifold Variations
Plug-in
Series VQ1000
Series VQ2000
Gateway-type
serial
transmission
system
Serial unit: EX510
IP20 enclosure
compliant
S
kit
Integrated-type
serial
transmission
system (for
Output)
P. 41
IP20 enclosure
compliant
P. 41
P. 45
IP20 enclosure
compliant
P. 45
Serial unit:
EX120/123/124
Dust-protected (-XP)
P. 45
Dust-tight,
Water-jet-proof (-W)
IP65 enclosure compliant
P. 45
IP65 enclosure
compliant
P. 49
W type only
P. 51
Integrated-type
serial
transmission
system (for I/O)
Serial unit: EX240
M
kit
Circular
connector
IP65
(Dust-tight, Water-jet-proof)
VQ-A.qxd
09.2.26 2:36 PM
Page 6
Bore size
Series
Average
speed
(mm/s)
VQ1101
Port size:
6 one-touch fitting
VQ2101
Port size:
8 one-touch fitting
10
16
Series CM2
Pressure 0.5 MPa
Load factor 50%
Stroke 300 mm
Series CJ2
Pressure 0.5 MPa
Load factor 50%
Stroke 60 mm
20
25
32
40
40
800
700
600
500
400
300
200
100
0
50
63
80
100
Perpendicular,
upward actuation
Horizontal actuation
800
700
600
500
400
300
200
100
0
It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder,
and its needle valve with being fully open.
The average velocity of the cylinder is what the stroke is divided by the total stroke time.
Load factor: ((Load mass x 9.8)/Theoretical force) x 100%
Conditions
Series
Conditions
Tube bore x Length
VQ1101
Series CM2
Speed controller
AS3001F-06
Silencer
AN200-KM8
VQ2101
Series CJ2
Speed controller
AS3001F-08
Silencer
AN200-KM10
09.3.3 11:32 AM
Page 7
VQ1000/2000
T kit (Terminal block box)
VQ1000/2000
L kit (Lead wire)
P. 33
3
4
1
2
4
3
2
3
P. 37
VQ1000/2000
S kit (Serial transmission) EX510
VQ1000/2000
S kit (Serial transmission) EX120/123/124
VQ1000/2000
S kit (Serial transmission) EX240
VQ2000
M kit (Circular connector)
VQ2000 Sub-plate Single Unit
VQ1000/2000 Semi-standard
VQ1000/2000 Construction
VQ1000/2000 Exploded View of Manifold
VQ1000/2000 Manifold Optional Parts
Safety Instructions
VQ1000/2000 Specific Product Precautions
P. 41
P. 45
P. 49
P. 51
P. 54
P. 55
P. 59
P. 61
P. 65
Back page 1
Back page 3
6
P kit
J kit
G kit
T kit
L kit
S kit
P. 29
M kit
VQ1000/2000
G kit (Flat ribbon cable with terminal block)
P. 25
Sub-plate
Single Unit
VQ1000/2000
J kit (Flat ribbon cable)
P. 21
Semistandard
VQ1000/2000
P kit (Flat ribbon cable)
P. 17
Construction
VQ1000/2000
F kit (D-sub connector)
P. 1
P. 3
P. 5
P. 7
P. 11
P. 15
Exploded
View of
Manifold
Features
Variations
Cylinder Speed Chart
VQ1000 How to Order, Manifold Options
VQ2000 How to Order, Manifold Options
VQ1000/2000 Model, Standard/Manifold Specifications
F kit
I N D E X
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
VQ-A.qxd
Plug-in Unit
Base Mounted
Series VQ1000
[Option]
Note) For CE compliant
models, DC-type only.
VV5Q 1 1 08 C6 F U1
CE compliant
Series
1
Nil
VQ1000
CE compliant
Manifold
1
Option
Plug-in unit
Symbol
Nil
Stations
01
2
B Note 2)
D
D0
D Note 7)
G1 Note 3)
G2 Note 3)
G3 Note 3)
J Note 4)
K Note 5)
N
R Note 6)
S
1 station
Kit type
The number of max. stations
differs from kit to kit.
(Refer to the below table.)
Cylinder port
Symbol
C3
C4
C6
M5
CM Note 1)
L3
L4
L6
Port size
With 3.2 One-touch fitting
With 4 One-touch fitting
With 6 One-touch fitting
M5 thread
Mixed sizes and with port plug
Top ported elbow with 3.2 One-touch fitting
Top ported elbow with 4 One-touch fitting
Top ported elbow with 6 One-touch fitting
Symbol
L5
B3
B4
B6
B5
LM Note 1)
MM Note 2)
Port size
Top ported elbow M5 thread
Bottom ported elbow with 3.2 One-touch fitting
Bottom ported elbow with 4 One-touch fitting
Bottom ported elbow with 6 One-touch fitting
Bottom ported elbow M5 thread
Elbow port, mixed sizes
Mixed size for different types of piping, option installed
Note 1) When two or more symbols are specified, indicate them alphabetically. Example: -BRS
Note 2) Models with a suffix -B have check valves for
prevention of back pressure at all manifold
stations. When a back pressure check valve is
desired, and is to be installed only in certain
manifold stations, specify the mounting position
by means of the manifold specification sheet.
Note 3) Specify the mounting position by means of the
manifold specification sheet.
Note 4) Refer to page 69 for details on with vacuum
ejector unit. A combination of J and N is not
available.
Note 5) Specify the wiring specifications by means of
the manifold specification sheet. (Except L kit)
Note 6) Indicate R for the valve with external pilot.
Note 7) : Station. Example: D08: The number of stations that may be displayed is longer than the
manifold number of stations.
Note 1) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 2) When selecting the mixed size for different types of piping or dual flow fitting assembly,
enter MM and give instructions in the manifold specification sheet.
Note 3) Inch-size One-touch fittings are also available. Refer to page 57 for details.
Note 4) M5 fittings for M5 thread are attached without being incorporated.
kit
(D-sub connector)
Top entry
kit
(Flat ribbon cable)
Option
None
200/220 VAC models (F/L kit only)
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring spec. (Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
kit
(Flat ribbon cable
20P)
kit
(Flat ribbon cable
with terminal block)
Top entry
Top entry
Note 1)
Note 1)
25P
20P
26P
Side entry
P. 17
Side entry
Side entry
P. 21
P. 25
Without cable
Note 2)
With cable (1.5 m)
2 to 16 G
With cable (3 m)
kit
stations
With cable (5 m)
Note 1) Besides the above, F/P kit with different number of pins are available. Refer to page 55 for details.
Note 2) Refer to page 56 for details.
Order separately
SI unit made by
OMRON Corp.
P. 29
0
1
2
3
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
Note 2)
2 to 16
stations
VQ 1 1 0 0
Example
CE compliant
Series
Nil
VQ1000
Double solenoid
(24 VDC)
VQ1200-51 (4 sets)
CE compliant
Blanking plate
VVQ1000-10A-1 (1 set)
sid
e
VQ
-1
00
-5
12
00
-5
12
00
-5
00
-5
-5
-5
11
00
-5
DC
C: Locking type
(Manual)
AC
(0.4 W)
Standard
High-speed (0.95 W)
response type
Cylinder port
fitting port size
C6: With 6 One-touch
fitting
D-sub connector
cable assembly
AXT100-DS25-030
Note 1)
F kit
(D-sub connector)
B
Nil
D: Slide locking
type (Manual)
Metal
0A
-5
12
11
00
11
Rubber
-1
00
12
00
10
00
2-position double
4
3-position pressure center
5
4-position dual 3-port valve
4
2
(A)
5
N.C.
3
N.C.
C Note)
11
Function
Symbol Specifications
B Note)
2-position double
A Note)
Metal seal
Rubber seal
0
1
12
VQ
00
-5
12
VQ
00
-5
12
VQ
00
-5
12
VQ
00
-5
11
VQ
00
-5
11
VQ
00
-5
1
10
VQ
0-5
11
00
-5
Seal
2-position single
VV
Q1
00
0-1
0A
-1
Manual override
Type of actuation
3m
S
ta
tio
ns
sid
e
Series VQ1000
3
N.O.
Note 3)
Negative
common
R Note 3)
External
pilot
VV5Q11-09C6FU2
VQ1100-51
VQ1200-51
VVQ1000-10A-1
Light/surge
voltage suppressor
Yes
None
Nil
E Note)
Coil voltage
1
2 Note)
3
4 Note)
5
6
CE compliant
3
N.O.
Caution
Use the standard (DC) specification when continuously energizing for
long periods of time.
kit
(Terminal block box)
kit
(Lead wire)
kit
(Serial transmission)
The valve is equipped with an
indicator light and surge voltage
suppressor, and the voltage is 24
VDC. The dust proof SI unit is
also available. Refer to page 45
for details.
Note) Refer to SI Unit Part No. on
page 45 when ordering the
CE-compliant
P. 45
SI unit.
3
4
1
2
4
3
2
3
2
1
P.
P. 33
T kit
L
kit
0
1
2
0
F1
H
J1
J2
S
Q
kit
R1
37
R2
V
1 to 8
ZB
stations
ZBN
Without SI unit
NKE Corp.: Fieldbus System
NKE Corp.: Fieldbus H System
SUNX Corp.: S-LINK (16 outputs)
SUNX Corp.: S-LINK (8 outputs)
DeviceNet
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
CompoNet (Positive common)
CompoNet (Negative common)
Note 2)
Max.16
stations
Max. 8 stations
Max.16
stations
Max. 8 stations
Max. 16
stations
VQ-A.qxd
09.2.26 2:36 PM
Page 10
Series VQ1000
VQ1000: Manifold Options
P. 65 to 69
VVQ1000-10A-1
VVQ1000-P-1- C6
N7
VVQ1000-R-1- C6
N7
VVQ1000-16A
C6 (SUP port)
6 one-touch fitting
F C3, C4
M5
VVQ1000-19A- P - C6,
N1, N3
L N7
VVQ1000-18A
VVQ1000-1C-
C6 (EXH port)
6 one-touch fitting
Connector assembly
[-D/-D0/-D]
VVQ1000-57A
Blanking plug
Port plug
KQ2P-
VVQ0000-58A
VVQ1000-F-L
[-S]
VVQ1000-52A- C8
N9
AN200-KM8/AN203-KM8
Refer to back page 4 for cylinder
port fittings part number.
Refer to page 62 for replacement
parts.
Exhaust
Regulator unit
VVQ1000-AR-1
VQ1000-FPG--
[-J]
SE
To
CY
po L
rt
VQ-A.qxd
09.2.26 2:36 PM
Page 11
10
Plug-in Unit
Base Mounted
Series VQ2000
[Option]
Note) For CE compliant
models, DC-type only.
VV5Q 2 1 08 C6 F U1
Symbol
Nil
Series
2
CE compliant
VQ2000
Nil
Manifold
1
Plug-in unit
Stations
01
1 station
Kit type
Cylinder port
Symbol
C4
C6
The maximum and
minimum number of
C8
stations are varied
CM Note 1)
depending on kit.
L4
(Refer to the below
L6
table.)
2
B Note 2)
D
D0
D Note 5)
K Note 3)
N
R Note 4)
S
CE compliant
Port size
With 4 One-touch fitting
With 6 One-touch fitting
With 8 One-touch fitting
Mixed sizes and with port plug
Top ported elbow with 4 One-touch fitting
Top ported elbow with 6 One-touch fitting
Symbol
L8
B4
B6
B8
LM Note 1)
MM Note 2)
Port size
Top ported elbow with 8 One-touch fitting
Bottom ported elbow with 4 One-touch fitting
Bottom ported elbow with 6 One-touch fitting
Bottom ported elbow with 8 One-touch fitting
Elbow port, mixed sizes
Mixed size for different types of piping, option installed
Note 1) When two or more symbols are specified, indicate them alphabetically. Example: -DNR
Note 2) Models with a suffix -B have check valves for
prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by
means of the manifold specification sheet.
Note 3) Specify the wiring specifications by means of
the manifold specification sheet. (Except L kit)
Note 4) Indicate R for the valve with external pilot.
Note 5) : Station. Example: D08: The number of stations that may be displayed is longer than the
manifold number of stations.
Note 1) Indicate Mixed size and with port plug by means of the manifold specification sheet.
Note 2) When selecting the mixed size for different types of piping, dual flow fitting
assembly, or double check block (direct mounting), enter MM and give
instructions in the manifold specification sheet.
Note 3) Inch-size One-touch fittings are also available. Refer to page 57 for details.
Simple specials are available with SMC Simple Specials System.
Refer to Best Pneumatics No. q for details on applicable models.
Side entry
Note 1)
Option
None
200/220 VAC models (F/L kit only)
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
Special wiring spec. (Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight, Water-jet-proof
(IP65) (T/L/S/M kit only)
kit
(Flat ribbon cable
20P)
kit
(Flat ribbon cable
with terminal block)
Side entry
Side entry
The voltage
used for the
valve is 24
VDC.
Note 1)
25P
26P
Top entry
20P
Top entry
kit
(Terminal block
box)
Top entry
kit
(Lead wire)
P. 25
P. 29
Without cable
U0
Note 2)
With cable (1.5 m)
U1
G
2 to 16
kit U2
With cable (3 m)
stations
With cable (5 m)
U3
Note 4)
kit
(Serial transmission)
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24
VDC. The dusttight SI unit is available. Refer to page 45 for details.
Dust-tight, Water-jet-proof (IP65)
is available.
Note) Refer to SI Unit Part No. on page 45 when
ordering the CE-compliant SI unit.
Note 2)
2 to 16
stations
kit
(Circularconnector)
P. 45
0 Without SI unit
F1 NKE Corp.: Uni-wire System
H NKE Corp.: Uni-wire H System
Note 2)
Max.16
stations
Dust-tight/Water-jet-proof
(IP65) compatible
P.
Dust-tight/Water-jet-proof
(IP65) compatible
T kit
11
P. 33
L
kit
0
1
2
S
kit
37
Note 1) Besides the above, F/P kit with different number of pins are available.
Refer to page 55 for details.
Note 2) Refer to page 56 for details.
Max. 8 stations
Q DeviceNet
Max.16
P. 51
Max. 8 stations
M
Max.16
kit
stations
0
1
2
3
Without cable
Note 2)
With cable (1.5 m)
2 to 24
With cable (3 m)
stations
With cable (5 m)
Note 3) Refer to the pages on respective kits for IP65 type. (T/L/S kit)
Note 4) Serial transmission system with IP65 enclosure applicable to input/output
is also available. Refer to page 49 for details.
Series VQ2000
VQ 2 1 0 0
Example
Double solenoid (24 VDC)
VQ2200-51 (4 sets)
Series
2
CE compliant
VQ2000
Nil
CE compliant
Blanking plate
VVQ2000-10A-1 (1 set)
sid
0
1
Metal seal
Rubber seal
2-position single
A Note)
Rubber
Metal
5
N.C.
Nil
W Note)
S
ta
tio
ns
e
sid
D
VV
VQ Q20
00
22
VQ
-10
00
22
-51
VQ
A-1
00
22
-5
00
22
-51 1
0
0-5
21
V
1
VQ Q210 00-5
1
21
0-5
00
1
-51
VQ
VQ
Type of actuation
1
3m
Enclosure
Seal
2-position double
B Note)
C Note)
Nil
E Note)
F kit
(D-sub connector)
Yes
None
3
N.O.
3
N.C.
2-position double
D-sub connector
cable assembly
AXT100-DS25-030
Light/surge
voltage suppressor
Coil voltage
3
N.O.
1
2 Note)
3
4 Note)
5
6
CE compliant
VV5Q21-08C8FU2
VQ2100-51
VQ2200-51
VVQ2000-10A-1
Manual override
Function
Symbol
Specifications
Nil
Standard
High-speed
response type
K Note 2)
DC
(0.4 W)
AC
Note 1)
(0.95 W)
N Note 3)
Negative
common
R Note 3)
External
pilot
Caution
Use the standard (DC) specification when continuously energizing for
long periods of time.
12
VQ-A.qxd
09.2.26 2:36 PM
Page 14
Series VQ2000
VQ2000: Manifold Options
P. 71 to 75
VVQ2000-10A-1
VVQ2000-P-1- C8
N9
VVQ2000-R-1- C8
N9
VVQ2000-16A
C8 (EXH port)
8 one-touch
fitting
C8 (SUP port)
8 one-touch
fitting
VVQ2000-19A
VVQ2000-24A-1
VVQ2000-18A
(1 to Max. stations)
Port plug
KQ2P-
VVQ1000-58A
[-D/-D0/-D]
VVQ2000-57A
AN200-KM10
VVQ2000-F-L
VVQ2000-52A- C10
N11
[-S]
VQ2000-FPG--
VVQ2000-23A-
IN
IN
B
B
13
To
CY
po L
rt
Color: red
VQ-A.qxd
09.2.26 2:36 PM
Page 15
14
VQ-A.qxd
09.2.26 2:36 PM
Page 16
Plug-in Unit
Base Mounted
Series VQ1000/2000
Model
Flow-rate characteristics Note 1)
Series
Type of
actuation
1 2/4 (P A/B)
Model
2-position
3-position
4-position
2-position
3-position
4-position
VQ2000
AC
C [dm /(sbar)]
Cv
C [dm /(sbar)]
Cv
Metal seal
VQ1100
0.70
0.15
0.16
0.72
0.25
0.18
15 or less
12 or less
29 or less
Rubber seal
VQ1101
0.85
0.20
0.21
1.0
0.30
0.25
20 or less
15 or less
34 or less
Metal seal
VQ1200
0.70
0.15
0.16
0.72
0.25
0.18
13 or less
10 or less
13 or less
Rubber seal
VQ1201
0.85
0.20
0.21
1.0
0.30
0.25
20 or less
15 or less
20 or less
Closed
center
Metal seal
VQ1300
0.68
0.15
0.16
0.72
0.25
0.18
26 or less
20 or less
40 or less
Rubber seal
VQ1301
0.70
0.20
0.16
0.65
0.42
0.18
33 or less
25 or less
47 or less
Exhaust
center
Metal seal
VQ1400
0.68
0.15
0.16
0.72
0.25
0.18
26 or less
20 or less
40 or less
Rubber seal
VQ1401
0.70
0.20
0.16
1.0
0.30
0.25
33 or less
25 or less
47 or less
VQ1500
0.70
0.15
0.16
0.72
0.25
0.18
26 or less
20 or less
40 or less
VQ1501
0.85
0.20
0.21
0.65
0.42
0.18
33 or less
25 or less
47 or less
Dual
Rubber seal
3-port valve
A
VQ1 B 01
C
0.70
0.20
0.16
0.70
0.20
0.16
33 or less
25 or less
47 or less
Metal seal
VQ2100
2.0
0.15
0.46
2.6
0.15
0.60
29 or less
22 or less
49 or less
Rubber seal
VQ2101
2.2
0.28
0.55
3.2
0.30
0.80
31 or less
24 or less
51 or less
Metal seal
VQ2200
2.0
0.15
0.46
2.6
0.15
0.60
20 or less
15 or less
20 or less
Rubber seal
VQ2201
2.2
0.28
0.55
3.2
0.30
0.80
26 or less
20 or less
26 or less
Closed
center
Metal seal
VQ2300
2.0
0.15
0.46
2.0
0.18
0.46
38 or less
29 or less
58 or less
Rubber seal
VQ2301
2.0
0.28
0.49
2.2
0.31
0.60
44 or less
34 or less
64 or less
Exhaust
center
Metal seal
VQ2400
2.0
0.15
0.46
2.6
0.15
0.60
38 or less
29 or less
58 or less
Rubber seal
VQ2401
2.0
0.28
0.49
3.2
0.30
0.80
44 or less
34 or less
64 or less
VQ2500
2.4
0.17
0.57
2.0
0.18
0.46
38 or less
29 or less
58 or less
VQ2501
3.2
0.28
0.80
2.2
0.31
0.60
44 or less
34 or less
64 or less
1.8
0.28
0.46
1.8
0.28
0.46
44 or less
34 or less
64 or less
Single
Double
Single
Double
Dual
Rubber seal
3-port valve
VQ2 B 01
C
Note 1) The values are given for port size C6: (VQ1000), C8: (VQ2000) without back pressure check valve.
Note 2) As per JIS B 8375-1981 (Supply pressure 0.5 MPa; with indicator light/surge voltage suppressor; clean air
The response time is subject to the pressure and quality of the air.) The values at the time of ON are given for double types.
15
High-speed
response:
0.95 W
Standard:
0.4 W
VQ1000
67
77
95
105
VQ-A.qxd
09.2.26 2:36 PM
Page 17
Series VQ1000/2000
Standard Specifications
JIS symbol
Fluid
Valve specifications
Metal
Rubber seal
Air, Inert gas
0.7 MPa
Single
0.1 MPa
0.15 MPa
Double
0.1 MPa
0.1 MPa
3-position
0.1 MPa
0.2 MPa
4-position
0.15 MPa
Rubber
Metal seal
Air, Inert gas
Valve type
2-position single
2-position double
2-position double
Minimum
operating pressure
10 to 50C Note 1)
Not required
Lubrication
Manual override
150/30 m/s2
Enclosure
3-position exhaust center
Electrical specifications
3
N.C.
Equivalent to Class B
Power consumption
(Current)
3
N.O.
3
N.O.
Manifold Specifications
Series
VQ1000
VQ2000
Base model
VV5Q11-
VV5Q21-
24 VDC
12 VDC
100 VAC
110 VAC
200 VAC
220 VAC
Note 1) Use dry air to prevent condensation when operating at low temperatures.
Note 2) Impact resistance No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)
Note 3) Value for high-speed response, high-voltage type (0.95 W)
Note 4) Dust-tight, Water-jet-proof (IP65) is available on T/L/S/M kit of the VQ2000.
Connection type
Piping
direction
F kitD-sub connector
P kitFlat ribbon cable
J kitFlat ribbon cable (20P)
G kitFlat ribbon cable with terminal
block
T kitTerminal block box
L kitLead wire
S kitSerial transmission
F kitD-sub connector
P kitFlat ribbon cable
J kitFlat ribbon cable (20P)
G kitFlat ribbon cable with terminal
block
T kitTerminal block box
L kitLead wire
S kitSerial transmission
M kitCircular connector
Piping specifications
Port size Note 1)
1(P), 3(R)
4(A), 2(B)
C8 (8)
Side
Option:
Direct EXH
outlet with
built-in
silencer
C3 (3.2)
C4(4)
C6 (6)
M5 (M5 thread)
Side
Applicable
solenoid valve
F/P/T kit
2 to 24 stations
J/G/S kit
2 to 16 stations
VQ100
VQ101
L kit
1 to 8 stations
5-station
mass
(g)
643
(Single)
754
(Double,
3-position)
F/P kit
2 to 24 stations
C10 (10)
Option:
Direct EXH
outlet with
built-in
silencer
Note 2)
Applicable
stations
C4 (4)
C6 (6)
C8 (8)
J/G/S kit
2 to 16 stations
L kit
1 to 8 stations
VQ200
VQ201
1076
(Single)
1119
(Double,
3-position)
T kit
2 to 20 stations
Note 1) Inch-size one-touch fittings are also available. Refer to page 57 for details.
Note 2) Refer to page 56 for details.
R port
R port
P port
P port
A, B port
A, B port
Type of connection
Type of connection
VV5Q11
VV5Q21
16
Series VQ1000/2000
VV5Q21
Manifold Specifications
Piping specifications
Series
Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)
VQ1000
Side
C8
VQ2000
Side
C10
Applicable
stations
Max. 24 stations
015
030
050
Cable
length (L)
10
1.5 m
3m
5m
Electrical characteristics
Item
Property
Note
AXT100-DS25-015
Cable 25 cores
AXT100-DS25-030
x 24AWG
AXT100-DS25-050
44
55
25
Socket side
13
47.04
65 or less
Voltage limit
V, 1 min, AC
1000
Insulation
resistance
M/km, 20C
5 or more
16
14
Conductor
resistance
/km, 20C
Terminal no.
Note 1) Types with 15 pins are also available. Refer to page 55 for details.
Note 2) Lengths other than the above are also available. Please contact SMC for details.
VV5Q 1 1
08 C6
Symbol
Nil
CE compliant
Nil
VQ1000
VQ2000
Manifold
1
Plug-in unit
Stations
02
U
S
Top entry
Side entry
Cylinder port
2 stations
Symbol
24 24 stations
Note) Refer to page 56
for details.
Cable (Length)
0
1
2
3
Port size
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
VQ1000 VQ2000
17
CE compliant
Connector entry
direction
[Option]
Option
U 1
Series
1
2
Note 2)
D
D0
D Note 3)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S
Option
VQ1000 VQ2000
None
200/220 VAC models
(F/L kit only)
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
(: Stations 02 to 24)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring specifications
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back
pressure at all manifold stations. When a back pressure check valve is
desired, and is to be installed only in certain manifold stations, specify
the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than
the manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for the details on with ejector unit. A combination of J and N is not available.
Note 6) Specify the wiring specifications by means of the manifold
specification sheet.
Note 7) Indicate R for the valve with external pilot.
Series VQ1000/2000
sid
e
J kit
U
sid
e
S
ta
tio
ns
P kit
F kit
Electrical
Wiring Specifications
Connector
terminal no.
VV5Q21
The total number of stations is tabulated
starting from station one on the D-side.
2-position double
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)
0
1
Metal seal
Rubber seal
SOL.A
SOL.B
19
SOL.A
SOL.B
20
SOL.A
SOL.B
21
9
SOL.B
22
SOL.A
10
Station 10
SOL.B
23
SOL.A
11
SOL.B
24
SOL.A
12
SOL.B
25
COM.
13
Station 11
Station 12
Positive
COM spec.
Negative
COM spec.
[Option]
Nil
Q
DC
(0.4 W)
Nil
Standard
High-speed (0.95 W)
response type
AC
Note 1)
CE compliant
Manual override
Nil
Negative
N Note 3) common
External
pilot
B
C
D
<Example>
D-sub connector kit with cable (3 m)
VV5Q11-09C6FU2
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1
Light/surge
voltage suppressor
Nil
1
2
3
4
5
6
ide
Us
Yes
None
Coil voltage
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
CE compliant
ns
tio
Sta
side
VVQ
1000
-10A
1
-5
00 1
12 -5
Q 00 1
V
12 -5
Q 00 1
V
12 -5
Q 00 1
V
12 -5
Q 00 1
V
11 -5
Q 00 1
V
11 -5
Q 00 1
V
11 0-5
Q
V 110
Q
V
Seal
18
Station 9
Function
R Note 3)
SOL.B
SOL.A
CE compliant
2-position single
3-position closed center
T kit
4
17
3m
Symbol Specifications
1
2
3
4
5
A
B
C
SOL.A
SOL.B
SOL.A
Series
Type of actuation
16
Sub-plate
Single Unit
VQ 1 1 0 0
VQ1000
VQ2000
SOL.B
1
2
Station 8
15
None
Black
None
Black
None
White
None
None
None
None
None
Black
None
White
White
White
Black
Red
Black
Red
Red
White
Red
None
Red
L kit
sid
D
Station 7
SOL.B
SOL.A
Dot marking
S kit
Station 6
-1
Caution
Use the standard (DC) specification when continuously energizing for
long periods of time.
18
Semistandard
Station 5
SOL.A
Polarity
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
(+)
Construction
S
ta
tio
ns
Station 4
sid
Station 3
1
14
Exploded
View of
Manifold
Station 2
VV5Q11
SOL.A
SOL.B
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Terminal no.
Station 1
M kit
015
AXT100-DS25- 030 Wire color
050
G kit
D-sub connector
Series VQ1000/2000
kit (D-sub connector)
VV5Q11
< >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].
(L4)
(L3)
L2
L1
63.5 <67.5>
(12)
(5.25)
28
P = 10.5
13
27
Indicator light
Manual
override
(5.5)
4.8
1.5
40.5
(35)
93.5 <100.4>
66
M4 mounting hole
35[25]
61
D side
Stations
U side
18.7
7.7
9.3
25
40.7
(7.5)
(12)
Dimensions
n
L1
L2
(L3)
(L4)
65.5
76
86.5
97
107.5 118
128.5 139
149.5 160
170.5 181
191.5 202
212.5 223
233.5 244
254.5 265
275.5 286
296.5
83.5
94
104.5 115
125.5 136
146.5 157
167.5 178
188.5 199
209.5 220
230.5 241
251.5 262
272.5 283
293.5 304
314.5
212.5 225
237.5 250
250
112.5 125
123
125
137.5 150
162.5 175
160.5 173
185.5 198
10
198
11
12
210.5 223
13
14
235.5 248
15
16
17
18
262.5 275
19
With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 46.3 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.
19
18.1
31.4
P = 10.5
20
287.5 300
285.5 298
21
22
312.5 325
310.5 323
23
325
24
337.5
VQ-A.qxd
09.2.26 2:36 PM
Page 21
Series VQ1000/2000
F kit
VV5Q21
(L4)
(L3)
L2
L1
73.5 <77.5>
34.5
13
34.5
P = 16
0.9
Indicator light
6.5
1
Manual
override
U side
Sub-plate
Single Unit
EXH
(7.5)
(12)
Construction
23
Exploded
View of
Manifold
16
31.6
49
24.5
9.5
EXH
41
C10 [1(P) SUP port]
C10: 10 one-touch fitting
Dimensions
n
L1
L2
(L3)
(L4)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
85
101
117
133
149
165
181
197
213
229
245
261
277
293
309
325
341
357
373
389
405
421
437
105
121
137
153
169
185
201
217
233
249
265
281
297
313
329
345
361
377
393
409
425
441
457
212.5 225
250
262.5 275
300
312.5 325
337.5 350
375
387.5 400
137.5 150
148
160.5 173
198
210.5 223
335.5 348
410.5 423
448
462.5 487.5
460.5 473
Semistandard
498
20
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
D side Stations
M kit
4 x M5 mounting hole
10.6
4
35
39.5
S kit
46.2
(35)
120 <126.9>
80
(5.5)
L kit
(12)
(5.25)
G kit
4.5
T kit
J kit
P kit
< >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].
Series VQ1000/2000
kit (Flat ribbon cable)
VV5Q11
VV5Q21
Manifold Specifications
Piping specifications
Series
Applicable
stations
Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)
Side
C8
VQ2000
Side
C10
Max. 24 stations
sid
e
S
ta
tio
ns
VQ1000
sid
e
Cable Assembly
1
to
3
tio
ta
sid
Terminal no.
sid
ns
VV5Q11
1.5 m
3m
5m
Note
Cable 26 cores
x 28AWG
For other commercial connectors, use a 26 pins type with strain relief
conforming to MIL-C-83503.
Cannot be used for transfer wiring.
Fujitsu Limited
Japan Aviation Electronics
Industry, Ltd.
Note 1) Other than the above model, 10P, 16P, 20P are also available. Refer to page 55 for details.
Note 2) Lengths other than the above are also available. Please contact SMC for details.
VV5Q 1 1
08 C6
PU
CE compliant
VQ1000
VQ2000
Connector entry
direction
Manifold
1
Stations
02
U
S
Plug-in unit
2 stations
Cylinder port
Symbol
C3 Note 1)
24 24 stations
C4 Note 1)
Note) Refer to
C6 Note 1)
page 56
C8 Note 1)
for details.
M5
CM Note 2) Note 3)
MM Note 4)
21
Top entry
Side entry
Port size
VQ1000 VQ2000
With 3.2 One-touch fitting
With 4 One-touch fitting
With 6 One-touch fitting
With 8 One-touch fitting
M5 thread
Mixed sizes and with port plug
Mixed size for different types of piping, option installed
[Option]
Option
Series
1
2
VV5Q21
Nil
CE compliant
Cable (Length)
0
1
2
3
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
Symbol
Nil
B Note 2)
D
D0
D Note 3)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S
Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
(: Stations 02 to 24)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring specifications
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back pressure at all
manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the
manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of
stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J and N is not
available.
Note 6) Specify the wiring specifications by means of the manifold specification sheet.
Note 7) Indicate R for the valve with external pilot.
Series VQ1000/2000
J kit
P kit
F kit
Station 4
Station 5
Station 6
Station 7
Station 8
Station 9
Connector
terminal no.
Station 10
SOL.B
SOL.A
SOL.B
SOL.A
SOL.B
10
SOL.A
11
SOL.B
12
SOL.A
13
SOL.B
14
SOL.A
15
SOL.B
16
SOL.A
17
SOL.B
18
SOL.A
19
SOL.B
20
SOL.A
Station 11
SOL.B
SOL.A
Station 12
SOL.B
Triangle mark
indicator position
21
22
23
24
COM.
25
COM.
26
Electrical wiring
specifications
VQ 1 1 0 0
Nil
VQ1000
VQ2000
Nil
2-position double
B
C
D
Nil
Symbol Specifications
Caution
DC
(0.4 W)
Nil
Standard
High-speed (0.95 W)
response type
High-pressure type (0.95 W)
Note 2)
Note 3)
Negative
common
R Note 3)
External
pilot
(1.0 MPa)
Yes
None
AC
Note 1)
Us
ns
tio
Sta
Coil voltage
Function
Seal
Metal seal
Rubber seal
VV5Q11-09C6PU2
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1
Manual override
2-position single
0
1
CE compliant
Type of actuation
1
2
3
4
5
A
B
C
<Example>
Flat ribbon cable kit with cable (3 m)
CE compliant
Series
1
2
[Option]
T kit
SOL.A
Station 3
L kit
SOL.B
S kit
SOL.A
Station 2
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
()
()
Note)
Negative
COM spec.
M kit
Sub-plate
Single Unit
SOL.B
1
3
5
6
CE compliant
ide
Ds
V
VVQ
1000
VQ
-10A
13
-1
00
-51
Q1
30
VQ
0-5
12
1
VQ
00
-51
12
VQ
00
11
-51
VQ
00
-51
11
VQ
00
-51
11
VQ
00
11
-5
1
00
-51
22
Semistandard
Station 1
Polarity
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
(+)
(+)
Positive
COM spec.
Construction
Exploded
View of
Manifold
SOL.A
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Terminal no.
G kit
Wiring Specifications
3m
Electrical
VQ-A.qxd
09.2.26 2:36 PM
Page 24
Series VQ1000/2000
VV5Q11
< >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-PS].
(L4)
(L3)
23.5
63.5 <67.5>
(12)
(5.25)
L2
L1
8.8
28
P = 10.5
13
27
Indicator light
Manual
override
(5.5)
4.8
1.5
40.5
(35)
93.5 <100.4>
66
M4 mounting hole
35
52
61.5
D side
Stations
U side
C8 [3(R) EXH port]
C8: 8 one-touch fitting
9.3
25
40.7
18.7
7.7
(7.5)
(12)
Dimensions
n
L1
L2
(L3)
(L4)
65.5
76
86.5
97
107.5 118
128.5 139
149.5 160
170.5 181
191.5 202
212.5 223
233.5 244
254.5 265
275.5 286
296.5
78.5
89
99.5 110
120.5 131
141.5 152
162.5 173
183.5 194
204.5 215
225.5 236
246.5 257
267.5 278
288.5 299
309.5
212.5 225
225
312.5 325
337.5
112.5 125
123
125
137.5 150
162.5 175
160.5 173
185.5 198
10
198
11
12
210.5 223
13
14
15
16
237.5 250
17
18
262.5 275
260.5 273
19
With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 41.3 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.
23
18.1
31.5
P = 10.5
285.5 298
20
298
21
22
310.5 323
23
24
335.5 348
VQ-A.qxd
09.2.26 2:36 PM
Page 25
Series VQ1000/2000
F kit
VV5Q21
P kit
< >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-PS].
L2
L1
Indicator light
J kit
13
P = 16
0.9
34.5
Manual
override
T kit
4 x M5 mounting hole
23.5
(L3)
(L4)
73.5
D side Stations
S kit
52
(5.25)
M kit
35
U side
EXH
(7.5)
(12)
Construction
23
41
Exploded
View of
Manifold
49
Semistandard
24.5
9.5
EXH
16
31.6
Dimensions
n
L1
L2
(L3)
(L4)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
85
101
117
133
149
165
181
197
213
229
245
261
277
293
309
325
341
357
373
389
405
421
437
100
116
132
148
164
180
196
212
228
244
260
276
292
308
324
340
356
372
388
404
420
436
452
125
150
162.5 175
412.5 425
450
462.5 475
185.5 198
223
235.5 248
273
Sub-plate
Single Unit
10.6
4
L kit
46.2
(35)
120 <126.9>
80
(5.5)
G kit
287.5 300
285.5 298
310.5 323
348
360.5 373
398
410.5 423
485.5
24
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
(12)
6.5
34.5
73.5 <77.5>
Series VQ1000/2000
kit (Flat ribbon cable)
VV5Q11
VV5Q21
Manifold Specifications
Piping specifications
Series
Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)
Side
C8
VQ2000
Side
C10
Max. 16 stations
U
s
S ide
ta
tio
ns
VQ1000
Applicable
stations
sid
e
Cable Assembly
1
AXT100-FC20- to
3
ns
ta
tio
sid
Terminal no.
VV5Q11
1.5 m
3m
5m
AXT100-FC20-1
AXT100-FC20-2
AXT100-FC20-3
sid
Note
Cable 20 cores
x 28AWG
VV5Q21
Note) Lengths other than the above are also available. Please contact SMC for details.
VV5Q 1 1
[Option]
08 C6
JU
Option
1
CE compliant
Series
1
2
VQ1000
VQ2000
Nil
U
S
Manifold
1
Plug-in unit
Top entry
Side entry
Stations
02
2 stations
Cylinder port
Symbol
16 16 stations
Note) Refer to
page 56
for details.
Connector entry
direction
Port size
Cable (Length)
0
1
2
3
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
VQ1000 VQ2000
25
CE compliant
Symbol
Nil
B Note 2)
D
D0
D Note 3)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S
Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
(: Stations 02 to 16)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring specifications
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Note 1) When two or more symbols are specified, indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back
pressure at all manifold stations. When a back pressure check valve is
desired, and is to be installed only in certain manifold stations, specify
the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J
and N is not available.
Note 6) Specify the wiring specifications by means of the manifold specification
sheet.
Note 7) Indicate R for the valve with external pilot.
Series VQ1000/2000
Wiring Specifications
Terminal no.
Station 2
SOL.B
SOL.A
Triangle
mark
indicator
position
Station 3
SOL.B
SOL.A
Station 4
SOL.B
SOL.A
Station 5
SOL.B
SOL.A
Station 6
SOL.B
SOL.A
Connector
terminal no.
Station 7
SOL.B
SOL.A
Station 8
SOL.B
16
14
12
10
8
6
19
17
15
13
11
9
7
5
(+)
(+)
()
()
(+)
(+)
()
()
(+)
(+)
()
()
(+)
(+)
()
()
(+)
(+)
()
()
(+)
(+)
()
()
(+)
(+)
()
()
(+)
(+)
(+)
(+)
()
()
T kit
18
M kit
4
3
COM.
2
1
Note)
Positive
COM spec.
Positive
COM spec.
[Option]
VQ 1 1 0 0
1
CE compliant
1
2
Series
Nil
VQ1000
VQ2000
Q
Nil
B
C
D
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)
Seal
0
1
Metal seal
Rubber seal
<Example>
Flat ribbon cable kit with cable (3 m)
VV5Q11-08C6JU2
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1
Yes
None
Nil
Us
ide
Sta
3m
1
2
3
4
5
A
B
C
CE compliant
Manual override
Type of actuation
tion
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
COM.
side
Coil voltage
5
Function
Symbol Specifications
24 VDC
DC
(0.4 W)
Nil
Standard
High-speed (0.95 W)
response type
High-pressure type (0.95 W) Note 1) Metal seal only
Note 2) Refer to Semi-standard on pages 56 to
57 for external pilot and negative common
Negative
specifications.
common
Note 3) When two or more symbols are specified,
External
indicate them alphabetically. Combination
pilot
of [B] and [K] is not possible.
L kit
SOL.B
SOL.A
S kit
19
17
15
13
11
9
7
5
3
1
Polarity
()
()
Sub-plate
Single Unit
20
18
16
14
12
10
8
6
4
2
20
Semistandard
SOL.A
Station 1
Construction
Exploded
View of
Manifold
Electrical
G kit
J kit
P kit
F kit
26
09.2.26 2:36 PM
Page 28
Series VQ1000/2000
VV5Q11
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS].
(L4)
(L3)
23.5
8.8
63.5
28
P = 10.5
13
27
Indicator light
Manual
override
(5.5)
40.5
type
66
(35)
93.5
4.8
1.5
(12)
(5.25)
L2
L1
VQ-A.qxd
4 x M4 mounting hole
35
52
D side
61.5
Stations
U side
18.7
7.7
(12)
(7.5)
n
L1
L2
(L3)
(L4)
X
P
P = 10.5
18.1
31.5
C8 [1(P) SUP port]
C8: 8 one-touch fitting
10
11
12
13
65.5
76
86.5
97
107.5
118
128.5
139
149.5
160
170.5
181
191.5
202
212.5
14
15
16
99.5
78.5
89
110
120.5
131
141.5
152
162.5
173
183.5
194
204.5
215
225.5
112.5
125
125
137.5
150
162.5
175
187.5
187.5
200
212.5
225
225
237.5
250
123
135.5
135.5
148
160.5
173
185.5
198
198
210.5
223
235.5
235.5
248
260.5
With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 41.3 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.
27
9.3
25
Dimensions
40.7
VQ-A.qxd
09.2.26 2:36 PM
Page 29
Series VQ1000/2000
F kit
VV5Q21
L2
L1
(12)
6.5
34.5
73.5
13
P = 16
0.9
Indicator light
34.5
G kit
23.5
Manual
override
1
(5.5)
T kit
J kit
P kit
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS].
52
4 x M5 mounting hole
(L3)
(L4)
(5.25)
M kit
73.5
S kit
10.6
4
46.2
L kit
(35)
80
120
PCW type
35
U side
Sub-plate
Single Unit
EXH
24.5
9.5
(7.5)
(12)
Construction
23
Exploded
View of
Manifold
49
16
31.6
EXH
41
C10 [1(P) SUP port]
C10: 10 one-touch fitting
Dimensions
n
L1
L2
(L3)
(L4)
Semistandard
10
11
12
13
14
15
16
85
101
117
133
149
165
181
197
213
229
245
261
277
293
309
100
116
132
148
164
180
196
212
228
244
260
276
292
308
324
125
150
162.5
175
187.5
212.5
225
237.5
262.5
275
287.5
300
312.5
337.5
350
135.5
160.5
173
185.5
198
223
235.5
248
273
285.5
298
310.5
323
348
360.5
28
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
D side Stations
Series VQ1000/2000
VV5Q21
Manifold Specifications
Piping specifications
Series
Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)
VQ1000
Side
C8
VQ2000
Side
C10
Applicable
stations
Max. 16 stations
Us
ide
tion
s
Sta
Cable Assembly
Ds
ide
AXT100-FC20- to
3
Terminal no.
Indicator light
VV5Q11
SI unit made by OMRON Corp.
Mountable for G71-OD16 (Order separately)
ns
tio
D
S
ta
Note
sid
e
Cable 20 cores
x 28AWG
sid
e
For other commercial connectors, use a 20 pins type with strain relief
conforming to MIL-C-83503.
Cannot be used for transfer wiring.
VV5Q21
Note) Lengths other than the above are also available. Please contact SMC for details.
VV5Q 1 1
[Option]
Option
08 C6 G
CE compliant
Nil
Series
1
2
Connector entry
direction, Top entry
VQ1000
VQ2000
Nil
Manifold
1
VQ1000
VQ2000
Plug-in unit
Cylinder port
Stations
02
2 stations
16 Note)
16 stations
Note) Refer to
page 56
for details.
29
Symbol
Port size
CE compliant
Cable (Length)
0
1
2
3
VQ1000 VQ2000
B Note 2)
D
D0
D Note 3)
Without cable
Cable length 1.5 m
Cable length 3 m
Cable length 5 m
Symbol
Nil
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S
Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
(: Stations 02 to 16)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring specifications
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Note 1) When two or more symbols are specified, indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the
mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J and
N is not available.
Note 6) Specify the wiring specifications by means of the manifold specification
sheet.
Note 7) Indicate R for the valve with external pilot.
Series VQ1000/2000
Connector
G kit
J kit
P kit
F kit
Assembly
T kit
Electric circuit diagram (Below wiring is the case of all double solenoid connections.)
Terminal no.
SOL.B
14
SOL.A
12
SOL.B
10
SOL.A
SOL.B
SOL.A
Station 5
19
SOL.B
17
Station 6
SOL.A
15
SOL.B
13
SOL.A
11
SOL.B
SOL.A
SOL.B
Station 4
Station 7
16
Station 8
Triangle mark
indicator position
L kit
Station 3
18
SOL.A
S kit
Station 2
20
SOL.B
M kit
Station 1
SOL.A
3.4
24 VDC +
1
CE compliant
1
2
Series
Seal
Nil
VQ1000
VQ2000
0 Metal seal
1 Rubber seal
Manual override
Nil
Type of actuation
Coil voltage
5
24 VDC
B
C
D
VV5Q11-08C6G2
VQ1100-51
VQ1200-51
VQ1300-51
Function
Symbol Specifications
Nil
B
K Note 1)
R Note 2)
Standard
Yes
None
DC
(0.4 W)
Sta U sid
e
tio
ns
2-position single
1
2-position double
2
3-position closed center
3
3-position exhaust center
4
3-position pressure center
5
A 4-position dual port (N.C. +N.C.)
B 4-position dual port (N.O. +N.O.)
C 4-position dual port (N.C. +N.O.)
CE compliant
<Example>
Flat ribbon cable kit with terminal block with cable
(3 m)
Ds
ide
High-speed (0.95 W)
response type
Note 1) Metal seal only
High- pressure type (0.95 W) Note 2) Refer to Semi-standard on page 57 for
external pilot specifications.
(1.0 MPa)
Note 3) When two or more symbols are specified,
External
indicate them alphabetically. Combination
pilot
of [B] and [K] is not possible.
30
Construction
Exploded
View of
Manifold
1 0 0
V
Q
13
V
Q 00
13 -5
V
Q 00 1
13 -5
V
Q 00 1
12 -5
V
Q 00 1
11 -5
V
Q 00 1
11 -5
V
Q 00 1
11 -5
00 1
-5
1
VQ 1
[Option]
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Semistandard
Sub-plate
Single Unit
1.2
09.2.26 2:36 PM
Series VQ1000/2000
kit (Flat ribbon cable with terminal block)
VV5Q11
The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].
(L4)
(L3)
L2
L1
Indicator light
Power supply terminal block
(Terminal screw M3)
13
63.5
(5.25)
P = 10.5
29
(12) 13
27
Manual
override
(5.5)
Indicator light
40
4.5
66
(35)
93.5
Page 32
VQ-A.qxd
4 x M4 mounting hole
2
43.8
63.4
D side Stations
U side
C8 [3(R) EXH port]
C8: 8 one-touch fitting
61
63.5
(12) 18.7
7.7
(7.5)
L1
L2
(L3)
(L4)
X
P
P = 10.5
18.1
31.5
66.5
77
87.5
98
108.5
119
129.5
140
150.5
161
171.5
182
192.5
203
213.5
84
94.5
10
11
12
13
14
15
16
105
115.5
126
136.5
147
157.5
168
178.5
189
199.5
210
220.5
231
112.5
125
125
137.5
150
162.5
175
187.5
187.5
200
212.5
225
237.5
250
262.5
123
135.5
135.5
148
160.5
173
185.5
198
198
210.5
223
235.5
248
260.5
273
With ejector unit: Formula L1 = 10.5n + 29.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 46.8 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.
31
Dimensions
L
9.3
13
25
40.7
VQ-A.qxd
09.2.26 2:36 PM
Page 33
Series VQ1000/2000
F kit
VV5Q21
P kit
The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).
J kit
6.5
Indicator light
34.5
Manual
override
T kit
4 x M5 mounting hole
D side Stations
(5.25)
M kit
73.5
U side
Sub-plate
Single Unit
35
10.6
46.2
L kit
(35)
80
120
24VDC
+ COM
(5.5)
G kit
(12) 13
P = 16
0.9
EXH
24.5
9.5
23
Dimensions
n
L1
L2
(L3)
(L4)
(7.5)
(12)
Construction
Exploded
View of
Manifold
49
Semistandard
EXH
R
16
31.6
S kit
34.5
73.5
41
C10 [1(P) SUP port]
C10: 10 one-touch fitting
10
11
12
13
14
15
16
85
101
117
133
149
165
181
197
213
229
245
261
277
293
309
119
135
151
167
183
199
215
231
247
263
279
295
311
327
343
150
162.5
175
187.5
212.5
225
237.5
262.5
275
287.5
300
325
337.5
350
362.5
160.5
173
185.5
198
223
235.5
248
273
285.5
298
310.5
335.5
348
360.5
373
32
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Indicator light
Series VQ1000/2000
IP65 compliant
VV5Q11
G 1/2
Electrical entry
sid
e
D
sid
e
S
ta
tio
ns
2 x G 3/4
Electrical entry
Manifold Specifications
Series
VQ1000
VQ2000
VQ
12
12
11
Piping specifications
Applicable
Port size
Piping
stations
direction 1(P), 3(R)
4(A), 2(B)
Side
C8
C3, C4, C6, M5 Max. 24 stations
Side
C10
C4, C6, C8
Max. 20 stations
VQ
VQ
-51
Electrical
Terminal no.
COM.
Station 1
Station 2
Station 3
M2.5
Station 4
Cover
Step 2. Wiring
Manifold
08 C6
Series
1
2
2 rows
9 to 12 stations
3 rows
Station 8
As the standard electrical wiring specifications, double wiring (connected to SOL. A and
SOL. B) is adopted for the internal wiring of each station for
12 stations or less, regardless
of valve and option types.
Mixed single and double wiring
is available as semi-standard.
Refer to page 56 for details.
T0
Nil
Plug-in unit
24 Note 1) 24 stations
Note 1) VQ2000: Max. 20 stations
Refer to page 56 for details.
For negative common specifications of series VQ1000, refer
to Semi-standard on page 56.
For series VQ2000 the
standard manifold can be used.
CE compliant
Stations
Cylinder port
Symbol
Port size
VQ1000 VQ2000
33
Station 9
Station 10
Station 11
Station 12
()
SOL.A
1A
()
(+)
SOL.B
1B
()
(+)
SOL.A
2A
()
(+)
SOL.B
2B
()
(+)
SOL.A
3A
()
(+)
SOL.B
3B
()
(+)
SOL.A
4A
()
(+)
SOL.B
4B
()
(+)
SOL.A
5A
()
(+)
SOL.B
5B
()
(+)
SOL.A
6A
()
(+)
SOL.B
6B
()
(+)
SOL.A
7A
()
(+)
SOL.B
7B
()
(+)
SOL.A
8A
()
(+)
SOL.B
8B
()
(+)
SOL.A
9A
()
(+)
SOL.B
9B
()
(+)
SOL.A
10A
()
(+)
SOL.B
10B
()
(+)
SOL.A
11A
()
(+)
SOL.B
11B
()
(+)
SOL.A
12A
()
(+)
SOL.B
12B
()
(+)
COM.
COM
(+)
()
Positive
COM spec.
Negative
COM spec.
Note)
[Option]
Option
Symbol
Nil
CE compliant
2 stations
Station 7
(+)
Manifold
02
Station 6
Polarity
COM
(b)
VQ1000
VQ2000
Station 5
Terminal block
2 to 8 stations
VV5Q 1 1
0-1
0A-1
-51
3.5
-51
-51
-51
-51
100
00
00
00
00
00
00
13
12
12
VVQ
VQ
VQ
VQ
B Note 2)
D
D0
D Note 6)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S
W
Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified (: Stations 02 to 24)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring spec. (Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight, Water-jet-proof (IP65)
Note 1) When two or more symbols are specified, indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back
pressure at all manifold stations. When a back pressure check valve
is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J
and N is not available.
Note 6) Specify the wiring specifications by means of the manifold specification sheet.
Note 7) Indicate R for the valve with external pilot.
Station 2
Station 3
Step 2. Wiring
Station 4
Cover
Station 5
Station 6
Station 7
As the standard electrical wiring specifications, double wiring (connected to SOL. A and
SOL. B) is adopted for the internal wiring of each station for
10 stations or less, regardless
of valve and option types.
Mixed single and double wiring
is available as semi-standard.
Refer to page 56 for details.
M3 Round head
combination screw
VQ 1 1 0 0
Station 10
1B
()
(+)
SOL.A
2A
()
(+)
SOL.B
2B
()
(+)
SOL.A
3A
()
(+)
SOL.B
3B
()
(+)
SOL.A
4A
()
(+)
SOL.B
4B
()
(+)
SOL.A
5A
()
(+)
SOL.B
5B
()
(+)
SOL.A
6A
()
(+)
SOL.B
6B
()
(+)
SOL.A
7A
()
(+)
SOL.B
7B
()
(+)
SOL.A
8A
()
(+)
SOL.B
8B
()
(+)
SOL.A
9A
()
(+)
SOL.B
9B
()
(+)
SOL.A
10A
()
(+)
SOL.B
10B
()
(+)
COM.
(+)
Negative
COM spec.
[Option]
()
Note)
Positive
COM spec.
S kit
Station 9
(+)
SOL.B
Station 8
()
P kit
1A
J kit
Station 1
Polarity
SOL.A
G kit
Terminal no.
F kit
T kit
Special
L kit
Terminal
Series VQ1000/2000
M kit
Enclosure
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)
Nil
W Note)
Dust-protected
Dust-tight, Water-jet-proof
(IP65)
ide
Us
Metal seal
Rubber seal
Sta
-1
0A
0-1 1
00
5
Q1 0VV 30 51
1
0Q
0
V
1
12 -5
0
Q
0
V
51
12
Q 00V
51
12
0VQ 20
51
1
Q 00V
11
Q
V
B
C
D
s
tion
ide
Ds
Manual override
Nil
Seal
0
1
VV5Q11-08C6T0
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1
Type of actuation
Yes
None
Coil voltage
Function
Symbol Specifications
Caution
Use the standard (DC)
specification when continuously
energizing for long periods of
time.
DC
(0.4 W)
Nil
Standard
High-speed (0.95 W)
response type
High-pressure type (0.95 W)
Negative
N Note 3) common
R Note 3)
External
pilot
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
1
2
3
4
5
A
B
C
CE compliant
AC
Note 1)
Semistandard
Construction
Nil
VQ1000
VQ2000
Exploded
View of
Manifold
1
2
Sub-plate
Single Unit
<Example>
CE compliant
Series
CE compliant
34
VQ-A.qxd
09.2.26 2:36 PM
Page 36
Series VQ1000/2000
VV5Q11
< >: AC
The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].
(L4)
(L3)
L2
Top entry port
Not machined
63.5 <67.5>
55
13
L1
P = 10.5
29
13
27
Indicator light
Manual
override
(5.5)
4.5
(12)
(5.25)
40
(35)
93.5 <100.4>
66
4 x M5 mounting hole
2
66
67
D side
Stations
U side
L1
L2
(L3)
(L4)
(7.5)
X
P
66.5
77
87.5
98
108.5 119
126
136.5 147
157.5 168
150
162.5 175
160.5 173
185.5 198
198
129.5 140
178.5 189
11
150.5 161
199.5 210
212.5 225
210.5 223
10
13
171.5 182
220.5 231
237.5 250
235.5 248
12
14
15
192.5 203
16
17
213.5 224
18.1
31.5
P = 10.5
18
19
234.5 245
20
241.5 252
262.5 273
283.5 294
304.5 315
287.5 300
312.5 325
325
273
285.5 298
310.5 323
21
255.5 266
260.5 273
With ejector unit: Formula L1 = 10.5n + 29.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 88.8 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.
35
18.7
(12)
n
9.3
25
40.7
61.5
7.7
G 1/2
Dimensions
L
325.5 336
337.5 350
22
23
276.5 287
346.5 357
362.5 375
360.5 373
24
297.5
387.5
385.5 398
VQ-A.qxd
09.2.26 2:36 PM
Page 37
Series VQ1000/2000
F kit
VV5Q21
(L4)
(L3)
L2
L1
(5.25)
P = 16
0.9
13
34.5
1
6.5
G kit
100
Manual
override
Indicator light
4A
3A
U SIDE
(35)
126
120 <126.9>
(5.5)
T kit
4B
L kit
46.2
S kit
4
10.6
4 x M5 mounting hole
1
U side
M kit
Stations
2 x G 3/4
Electrical entry
EXH
EXH
R
(7.5)
(12)
120 <126.9>
126
80
9.5
4B
2B
3B
1B
23
49
41
6.5
Exploded
View of
Manifold
Dust-tight, Water-jet-proof
Dimensions
n
L1
L2
(L3)
(L4)
10
11
12
13
14
15
16
17
18
19
20
150.5
166.5
182.5
198.5
214.5
230.5
246.5
262.5
278.5
294.5
310.5
326.5
342.5
358.5
374.5
390.5
406.5
422.5
438.5
163
179
195
211
227
243
259
275
291
307
323
339
355
371
387
403
419
435
451
187.5
200
225
237.5
250
262.5
287.5
300
312.5
337.5
350
362.5
375
400
412.5
425
450
462.5
475
198
210.5
235.5
248
260.5
273
298
310.5
323
348
360.5
373
385.5
410.5
423
435.5
460.5
473
485.5
36
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
4A
TERMINANAL
NO.
3A
2A
1A
U SIDE
D SIDE
STA
46.5
24.5
16
31.6
(L4)
(L3)
L2 + 0.5
L1 + 0.5
100.5
Sub-plate
Single Unit
D side
Semistandard
6.5
76
Construction
3B
1B
2B
TERMINANAL
NO.
1A
2A
D SIDE
STA
80
(12)
J kit
P kit
< >: AC
The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).
Series VQ1000/2000
2
1
IP65 compliant
VV5Q11
Manifold Specifications
Piping specifications
Series
COM. (+)
SOL.B
()
VQ2000
Side
C10
Max. 8 stations
tio
ns
U
ta
S
3
2
COM. (+)
SOL.B
Single solenoid
C8
()
Black
()
Red
White
Side
Applicable
stations
sid
e
Black
VQ1000
Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)
sid
e
VV5Q21
Red
White
Double solenoid
4
1
2
3
4
3
2
3
ns
ta
Station
number
tio
sid
sid
VV5Q11
Part no.
VVQ1000-84A-6VVQ1000-84A-15VVQ1000-84A-30-
Station number 1 to 8
VV5Q 1 1
06 C6
CE compliant
Cable (Length)
0
1
2
Manifold
1
Plug-in unit
Stations
01
Symbol
Nil
Nil
VQ1000
VQ2000
1 station
CE compliant
Cylinder port
Symbol
Port size
VQ1000 VQ2000
37
[Option]
Option
Series
1
2
VV5Q21
2
B
Note 2)
D
D0
D Note 3)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
N
R Note 6)
S
W
VQ1000 VQ2000
Option
None
200/220 VAC models
(F/L kit only)
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified (: Stations 02 to 08)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
With name plate
External pilot
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight, Water-jet-proof (IP65)
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the
mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the
manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of
J and N is not available.
Note 6) Indicate R for the valve with external pilot.
SOL.A
Red
VV5Q21
(+)
SOL.B
White
Single solenoid
Dust-tight, Water-jet-proof
Red
COM. () Black
COM. () Black
SOL.B
(+)
(+)
White
Double solenoid
G kit
SOL.A
P kit
J kit
Wiring
F kit
Series VQ1000/2000
T kit
Station
number
Cable 3 cores x 24AWG
L kit
Station number 1 to 8
S kit
Part no.
VVQ1000-84AN-6-
VVQ1000-84AN-15-
VVQ1000-84AN-30-
Note) When using the negative common specifications, use valves for negative common. For negative common specifications, refer to Semistandard on page 56.
CE compliant
Type of actuation
Seal
Nil
Metal seal
Rubber seal
CE compliant
Enclosure
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)
Nil
W Note)
Dust-protected
Dust-tight, Water-jet-proof
(IP65)
VV5Q11-06C6L2
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1
Us
Manual override
s
tion
Sta
ide
Ds
2
Function
DC
(0.4 W)
2
3
Nil
Negative
N Note 3) common
R Note 3)
External
pilot
Coil voltage
1
2
3
4
5
6
CE compliant
Sub-plate
Single Unit
-1
-10A
High-speed (0.95 W)
response type
1000
Note 1)
VVQ
1
2
3
Standard
B
C
D
Nil
Nil
AC
1
-5
00 1
-5
12
Q
00 1
V
-5
11
Q
00 1
V
11 0-5
Q
0
1
V
11 0-5
Q
0
V
11
Q
V
Symbol Specifications
1
2
3
4
5
A
B
C
0
1
VQ1000
VQ2000
<Example>
Lead wire kit with cable (3 m)
Semistandard
Series
1
2
Construction
1 0 0
Exploded
View of
Manifold
VQ 1
[Option]
Caution
Use the standard (DC) specification when
continuously energizing for long periods
of time.
38
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
M kit
VQ-A.qxd
09.2.26 2:36 PM
Page 40
Series VQ1000/2000
kit (Lead wire)
VV5Q11
< >: AC
The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).
(L4)
(L3)
L2
L1
28
63.5 <67.5>
(12)
(5.25)
P = 10.5
13
11.2
Manual
override
Indicator light
A
3 2 1
40.5
(35)
3 2 1
3 2 1
93.5 <100.4>
66
Number of
stations
(5.5)
1.5
Lead wire
AWG24 x 3 cores
4 x M4 mounting hole
61.5
D side
Stations
U side
7.7
20
33.3
(7.5)
18.7
(12)
40.7
25
9.3
P = 10.5
C3, C4, C6, M5 [4(A), 2(B) port]
C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread
Dimensions
n
L1
L2
(L3)
(L4)
70.5
81
91.5
39
49.5
60
48.5
59
69.5
80
90.5
75
87.5
87.5
100
112.5
85.5
98
98
110.5
123
112.5
101
111.5
122
125
137.5
150
135.5
148
160.5
With ejector unit: Formula L1 = 10.5n + 28.5 + (Number of ejector units x 26.7)
L2 = 10.5n + 38 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.
39
102
Page 41
VV5Q21
(L4)
(L3)
L2
L1
Number of
stations
73.5 <77.5>
13
(5.25)
5.5
J kit
34.5
0.9
P kit
< >: AC
The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).
Lead wire
AWG24 x 3 cores
Manual override
Indicator light
4 x M5 mounting hole
S kit
10.6
4
46.2
L kit
(35)
120 <126.9>
80
(5.5)
G kit
16.5
1
Dust-tight, Water-jet-proof
1
U side
M kit
Stations
Sub-plate
Single Unit
D side
Semistandard
Construction
49
31.6
24.5
16
9.5
(7.5)
(12)
C10 [1(P) SUP port]
C10: 10 one-touch fitting
23
41
P = 16
Dimensions
n
L1
L2
(L3)
(L4)
Exploded
View of
Manifold
(12)
Series VQ1000/2000
F kit
T kit
09.2.26 2:36 PM
51
67
83
99
115
131
147
163
63
79
95
111
127
143
159
175
87.5
100
125
137.5
150
162.5
184.5
200
98
110.5
135.5
148
160.5
173
198
210.5
40
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
VQ-A.qxd
Series VQ1000/2000
kit (Serial transmission) Base mounted plug-in manifold: For EX510 Gateway-type serial transmission system
VV5Q 1 1 SB
08
CE compliant
Manifold series
1
2
Nil
VQ1000
VQ2000
Valve stations
Symbol Stations
01
EX510-S102A
08
1 station
8 stations
Cylinder port
Symbol
Inch size
Metric size
C3
C4
C6
C8
M5
CM Note 1)
L3
L4
L6
L8
L5
B3
B4
B6
B8
B5
LM Note 1)
N1
N3
N7
N9
M5T
NM Note 1)
LN1
LN3
LN7
LN9
L5T
BN1
BN3
BN7
BN9
B5T
LNM Note 1)
MM Note 2)
Port size
VQ1000 VQ2000
D Note 1)
B Note 3)
D Note 9)
G1 Note 4) Note 8)
G2 Note 4) Note 8)
G3 Note 4) Note 8)
J Note 5) Note 8)
K Note 6)
N
R Note 7)
S
Example
ide
Us
ns
tio
Sta
ide
Ds
Note 1) Indicate Mixed sizes and with port plug in the manifold specification sheet.
Note 2) When selecting the mixed size for different types of piping, dual flow fitting
assembly, or double check block (direct mounting), enter MM and give
instructions in the manifold specification sheet.
Refer to Best Pneumatics No. q for details on EX510 gatewaytype serial transmission system.
41
CE compliant
Option
SI unit specifications
Nil
[Option]
VV5Q11-SB08C6-D
VQ1100-51
VQ1200-51
VQ1300-51
The asterisk denotes the symbol for assembly. Prefix it to the part
nos. of the solenoid valve, etc.
Enter in order starting from the first station on the D-side.
Add the valve and option part numbers under the manifold base part number. In the case
of complex arrangement, specify them by means of the manifold specification sheet.
Series VQ1000/2000
VQ 1 1 0 0
[Option]
1
Nil
VQ1000
VQ2000
CE compliant
Manual override
G kit
1
2
J kit
CE compliant
Series
Nil: Non-locking
push type
(Tool required)
Type of actuation
2-position single
P kit
F kit
T kit
B: Locking type
Metal
2-position double
L kit
2-position double
C: Locking type
S kit
Rubber
(Tool reguired)
(Manual)
M kit
3
3-position exhaust center
Sub-plate
Single Unit
(Manual)
3
N.O.
24 VDC
Function
Semistandard
Rated voltage
Note)
3
N.C.
Construction
Note)
Symbol
Specifications
Nil
Standard (0.4 W)
Exploded
View of
Manifold
5
N.C.
3
N.O.
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
A Note)
Seal
0
1
Metal seal
Rubber seal
42
VQ-A.qxd
09.2.26 2:36 PM
Page 44
Series VQ1000/2000
kit (Serial transmission) Base mounted plug-in manifold: For EX510 Gateway-type serial transmission system
VV5Q11
L4
L3
L2
33
8.8
L1
(n-1) x 10.5
10.5
28
63.5
13
27
Indicator light
A
0
1
PWR
COM
40
8
9
5.5
35
6
7
93.5
66
14
15
35
Manual
override
(12)
5.25
52
61.5
D side
Stations 1
U side
43
X
P
9.3
7.5
L1
L2
L3
L4
12 18.7
n
Dimensions
L
25
40.7
7.7
18.1
31.5
10
11
12
13
55
65.5
76
86.5
97
107.5
118
128.5
139
149.5
160
170.5
181
191.5
14
202
15
212.5
16
101.5
112
122.5
133
143.5
154
164.5
175
185.5
196
206.5
217
227.5
238
248.5
259
125
137.5
150
162.5
175
175
187.5
200
212.5
225
237.5
237.5
250
262.5
275
287.5
135.5
148
160.5
173
185.5
185.5
198
210.5
223
235.5
248
248
260.5
273
285.5
298
VQ-A.qxd
09.2.26 2:36 PM
Page 45
Series VQ1000/2000
F kit
P kit
VV5Q21
L4
L3
L2
6.5
34.5
P = 16
0.9
Indicator light
34.5
Manual
override
8
9
L kit
Stations
U side
M kit
D side
Sub-plate
Single Unit
EXH
R
7.5
Exploded
View of
Manifold
12 16
31.6
49
Semistandard
EXH
R
23
41
C10 [1(P) SUP port]
C10: 10 one-touch fitting
Dimensions
n
L1
L2
L3
L4
Construction
52
10
11
12
13
14
15
16
69
85
101
117
133
149
165
181
197
213
229
245
261
277
293
309
117
133
149
165
181
197
213
229
245
261
277
293
309
325
341
357
137.5
162.5
175
187.5
212.5
225
237.5
250
275
287.5
300
312.5
337.5
350
362.5
387.5
148
173
185.5
198
223
235.5
248
260.5
285.5
298
310.5
323
348
360.5
373
398
44
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
35
S kit
10.6
4
PWR
COM
46.2
35
80
120
14
15
5.5
13
J kit
L1
8.5
G kit
33
73.5
(12)
(5.25)
T kit
Series VQ1000/2000
kit (Serial transmission): For EX120/123/124 Integrated-type (Output) serial transmission system
IP65 compliant
Manifold Specifications
Piping specifications
Series
Applicable
stations
Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)
VQ1000
Side
C8
VQ2000
Side
C10
C4, C6, C8
VV5Q 1 1
08 C6
SV
XP
CE compliant
Series
1
2
Enclosure
VQ1000
VQ2000
Nil
XP Note)
Plug-in unit
Stations
02
2 stations
16 Note)
16 stations
C3 Note 1)
C4 Note 1)
C6 Note 1)
C8 Note 1)
M5
CM Note 2) Note 3)
MM Note 4)
Symbol
0
F1
H
J1
J2
Q
R1
R2
V
ZB
ZBN
F1
H
J1
J2
Q
R1
R2
V
ZB
ZBN
Stations
Protocol
Without SI unit
NKE Corp.: Fieldbus System
Max.16
stations
NKE Corp.: Fieldbus H System
SUNX Corp.: S-LINK (16 outputs)
Max. 8 stations
SUNX Corp.: S-LINK (8 outputs)
DeviceNet System
Max.16
OMRON Corp.: CompoBus/S (16 outputs) stations
OMRON Corp.: CompoBus/S (8 outputs) Max. 8 stations
CC-LINK
Max.16
CompoNet (Positive common)
stations
CompoNet (Negative common)
Note 1) Insert L (Top ported) or B (Bottom
ported) for elbow type.
Example) B6 (Bottom ported elbow
with 6 one-touch fitting)
Note 2) Indicate as LM for models with elbow
fittings and mixed cylinder port sizes.
Note 3) Indicate Mixed sizes and with port
plug by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct
mounting), enter MM and give instructions in the manifold specification sheet.
Note 5) Inch-size one-touch fittings are available. Refer to Semi-standard on page
included.]) 57 for details.
Port size
VQ1000 VQ2000
With 3.2 one-touch fitting
With 4 one-touch fitting
With 6 one-touch fitting
With 8 one-touch fitting
M5 thread
Mixed sizes and with port plug
Mixed size for different types
of piping, option installed
Protocol
CE compliant
SI unit part no.
Standard: EX120-SUW1
Dust-protected: EX120-SUW1-XP
Standard: EX120-SUH1
NKE Corp.: Fieldbus H System
Dust-protected: EX120-SUH1-XP
Standard: EX120-SSL1
SUNX Corp.: S-LINK
(16 outputs)
Dust-protected: EX120-SSL1-XP
Standard: EX120-SSL2
SUNX Corp.: S-LINK
(8 outputs)
Dust-protected: EX120-SSL2-XP
Standard: EX120-SDN1
DeviceNet
Dust-protected: No part no.
OMRON Corp.: CompoBus/S Standard: EX120-SCS1
(16 outputs)
Dust-protected: EX120-SCS1-XP
OMRON Corp.: CompoBus/S Standard: EX120-SCS2
(8 outputs)
Dust-protected: EX120-SCS2-XP
Standard: EX120-SMJ1
CC-LINK
Dust-protected: EX120-SMJ1-XP
Standard: EX120-SCM1
CompoNet (Positive common)
Dust-protected: No part no.
Standard: EX120-SCM3
CompoNet (Negative common)
Dust-protected: No part no.
NKE Corp.: Fieldbus System
Symbol
Nil
B Note 2)
D
D Note 3)
Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
DIN rail mounting
(: Stations 02 to 24)
F1
H
J1
J2
Q
R1
R2
V
Protocol
NKE Corp.: Fieldbus System
NKE Corp.: Fieldbus H System
SUNX Corp.: S-LINK (16 outputs)
SUNX Corp.: S-LINK (8 outputs)
DeviceNet System
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
Refer to Best Pneumatics No. q for details on the EX120/123/124 integrated-type (Output) serial transmission system.
Refer to SMC Information (08-E543) for details on CompoNet.
45
CE compliant
Option
SI unit specifications
Cylinder port
Symbol
Manifold
1
Nil
Dust-protected
Series VQ1000/2000
VV5Q21
Dust-protected (-XP)
[Option]
VQ 1 1 0 0
1
CE compliant
Series
Nil
VQ1000
VQ2000
CE compliant
Enclosure
Nil
Type of actuation
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)
W Note)
ide
Us
Metal seal
Rubber seal
S kit
ide
Ds
VVQ
1000
VQ
-10A
130
VQ
-1
0-5
12
VQ
1
120 00-51
VQ
0-5
120
1
0-5
1
2
VQ
1
00-5
11
VQ
1
110 00-51
0-5
1
VQ
M kit
B
C
D
Nil
ta
tio
ns
Manual override
Seal
Coil voltage
24 VDC;
With indicator light/
surge voltage suppressor
Sub-plate
Single Unit
Function
Nil
Standard
DC
(0.4 W)
Semistandard
Symbol Specifications
High-speed (0.95 W)
response type
Construction
R Note 2
External
pilot
Exploded
View of
Manifold
(1.0 MPa)
Note 2)
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
0
1
Dust-protected
Dust-tight, Water-jet-proof
(IP65)
1
2
3
4
5
A
B
C
<Example>
VV5Q11-08C6SV
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1
1
2
G kit
VV5Q11
T kit
VV5Q21
VV5Q11
L kit
J kit
P kit
F kit
G 1/2
46
VQ-A.qxd
09.2.26 2:36 PM
Page 48
Series VQ1000/2000
kit (Serial transmission): For EX120 Integrated-type (Output) serial transmission system
The dashed lines indicate DIN rail
mounting [-D] (with DIN rail
mounting bracket).
L7
L6
L5
VV5Q11
(L1)
(n-1) x 10.5
28
1.5
A
-
T/R
ERR
1
+
FG
SC (SI No.EX120-STA1)
DIP SW.
MODEL
66
64
RUN
93.5
0V
SERIAL UNIT
SMC
24V
Dust-protected SI unit
(L4)
(L3)
L2
63.5
(12)
23.5
1.5
13
(5.25)
L1
(n-1) x 10.5
10.5
28
Indicator light
27
Manual override
A
DIP SW.
FG
SC (SI No.EX120-STA1)
2
4.5
MODEL
(5.5)
T/R
ERR
(35)
RUN
93.5
0V
SERIAL UNIT
66
64
SMC
24V
61.5
4 x M4 mounting hole
Stations
U side
(12) 18.7
7.7
47
9.3
(7.5)
n
P = 10.5
18
31.5
Dimensions
L1
L2
(L3)
(L4)
25
40.7
65.5
76
86.5
97
107.5
118
128.5
139
149.5
10
160
11
170.5
12
181
13
191.5
14
202
15
212.5
16
93.5
104
114.5
125
135.5
146
156.5
167
177.5
188
198.5
209
219.5
230
240.5
125
125
137.5
150
162.5
175
187.5
187.5
200
212.5
225
237.5
250
250
262.5
135.5
135.5
148
160.5
173
185.5
198
198
210.5
223
235.5
248
260.5
260.5
273
10.7.16 11:44 AM
Page 1
Series VQ1000/2000
The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).
L11 = L4 + 50
L10 = L3 + 50
L9 = 16n + 131
82
P kit
L7 = L4 + 25
L6 = L3 + 25
L5 = 16n + 108
L1
34.5
(n-1) x 16
J kit
VV5Q21
G kit
L kit
34.5
1
73.5
T kit
100
L8 = 16n + 118.5
(5.25)
34.5
P = 16
6.5
1
13
S kit
FG
(SI No.EX124-SMB1)
DIP SW.
SC (SI No.EX120-STA1)
46.2
MODEL SB
MODEL
T/R
ERR
120
80
x 10
RUN
10.6
4
x1
0V
SERIAL UNIT
Dust-protected SI unit
(12)
STATION NO.
SERIAL UNIT
SMC
24V
EX123: 2 x G1/2
EX124: 4 x G1/2
Electrical entry
Use a drip proof plug assy
(AXT100-B04A) on the
unused conduit port (G1/2).
F kit
286-VQ-CT.qxd
Indicator light
0.9
Sub-plate
Single Unit
Semistandard
FG
46.2
DIP SW.
SC (SI No.EX120-STA1)
D side
Stations
Construction
MODEL
4 x M5 mounting hole
U side
24.5
16
31.6
49
9.5
(7.5)
(12)
L1
L2
(L3)
(L4)
23
P = 16
41
Dimensions
L
Exploded
View of
Manifold
EXH
R
10
11
12
13
14
15
16
85
101
117
133
149
165
181
197
213
229
245
261
277
293
309
115
131
147
163
179
195
211
227
243
259
275
291
307
323
339
137.5
162.5
175
187.5
200
225
237.5
250
262.5
287.5
300
312.5
337.5
350
362.5
148
173
185.5
198
210.5
235.5
248
260.5
273
298
310.5
323
348
360.5
373
48
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
T/R
ERR
(35)
RUN
120
80
0V
SERIAL UNIT
10.6
4
SMC
24V
(5.5)
M kit
Manual override
Series VQ2000
kit (Serial transmission): For EX240 Integrated-type (I/O) serial transmission system
IP65 compliant
VQ2000 only
The serial transmission system reduces wiring work, while
minimizing wiring and saving space.
VV5Q21
[Option]
08 C6
SD
QW 1
N W
CE compliant
VQ2000
Plug-in series
Nil
Stations
01
Enclosure
IP65 (Dust-tight, Water-jet-proof)
1 station
16 16 stations
Option
Option
None
With back pressure check valve
Special wiring spec. (Except double wiring)
With name plate
External pilot
Symbol
Nil
Cylinder port
Symbol
CE compliant
B
K
N
R
Port size
DI unit specifications
Nil
Number of DI unit
Nil
0
1
2
3
4
Model
0W Without SI unit
QW DeviceNet
NWN PROFIBUS-DP
+COM.
COM.
VQ 2 1 0 0
W1
Enclosure
IP65 (Dust-tight, Water-jet-proof)
Seal
0
1
Manual override
Metal seal
Rubber seal
Nil
B
C
D
Type of actuation
1
2
3
4
5
A
B
C
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)
49
Nil
CE compliant
Coil voltage
Function
Symbol
Specifications
Nil
Standard
B
K Note 1)
CE compliant
N Note 2)
R Note 2)
DC
High-speed
response type
(0.95 W)
Caution
Use the standard (DC)
specification when continuously
energizing for long periods of
time.
VQ-A.qxd
09.2.26 2:36 PM
Page 51
Series VQ2000
F kit
VV5Q21
L2 (In case of 1 pc. input block: 8 number of inputs)
L1
(143)
8.1
54
Min. 0 to
Max. 4 unit
(0 to 216 mm)
P = 16
0.9
34.5
6.5
16.5
J kit
14.6
P kit
Manual override
4 x M5 mounting hole
L kit
10.5
4
Input block
D side
Stations
U side
S kit
T kit
80
120
120
G kit
Indicator light
23
M kit
Sub-plate
Single Unit
23
P = 16
Semistandard
41
C10 [1(P) SUP port]
C10: 10 one-touch fitting
Formula L1 = 16n + 36.5 L2 = 16n + 186 (In case of 1 pc. DI unit, 54 mm will be added for increasing every 1 pc.)
n: Station (Maximum 24 stations)
Dimensions
L1
L2
68.5
84.5 100.5 116.5 132.5 148.5 164.5 180.5 196.5 212.5 228.5 244.5 260.5 276.5 292.5 308.5 324.5 340.5 356.5 372.5 388.5 404.5 420.5
218
234
4
250
5
266
6
282
7
298
8
314
9
330
10
346
11
362
12
378
13
394
14
410
15
426
16
442
17
458
18
474
19
490
20
506
21
522
22
538
23
554
24
570
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Construction
Exploded
View of
Manifold
1.6
16
24.5
49
73.7
9.5
13.2
75.5
61.5
50
Series VQ2000
kit (Circular connector)
VQ2000 only
VV5Q21
Manifold Specifications
Piping specifications
Applicable
stations
Series
Piping
direction
1(P), 3(R)
4(A), 2(B)
VQ2000
Side
C10
C4, C6, M8
Port size
Max. 24 stations
AXT100-MC26- 030
050
10
Electrical characteristics
Item
Property
Conductor resistance 65
/km, 20C or less
Voltage limit
V, 1 min, AC
1000
Insulation resistance
5
M/km, 20C or more
60
30
2
3
13
23
26
19
14
24
25
18
15
16
17
20
12
22
11
21
10
7
Socket side
Note) Lengths other than the above are also available. Please contact SMC for details.
VV5Q 2 1
08 C6
N W
CE compliant
Series
2
Enclosure
IP65 (Dust-tight, Water-jet-proof)
VQ2000
Plug-in unit
Cable (Length)
Cylinder port
Symbol
Stations
02
2 stations
24 24 stations
Note) Refer to
page 56
for details.
51
Nil
CE compliant
Option
Manifold
1
[Option]
C4 Note 1)
C6 Note 1)
C8 Note 1)
CM Note 2) Note 3)
MM Note 4)
Port size
With 4 One-touch fitting
With 6 One-touch fitting
With 8 One-touch fitting
Mixed sizes and with port plug
Mixed size for different types of piping, option installed
0
1
2
3
Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)
Symbol
Nil
B Note 2)
D
D0
D Note 3)
K Note 4)
N
R Note 5)
Option
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail mounting (: Stations 02 to 24)
Special wiring spec. (Except double wiring)
With name plate
External pilot
Series VQ2000
Station 2
VV5Q21
16
24
13
21
Station 3
3
18
19
Station 4
Station 5
SOL.B
SOL.A
6
9
SOL.B
SOL.A
20
10
SOL.B
SOL.A
17
26
22
11
25
23
12
15
14
SOL.B
SOL.A
Station 6
SOL.B
SOL.A
Station 7
SOL.B
SOL.A
Station 8
SOL.B
SOL.A
Station 9
SOL.B
SOL.A
Station 10
SOL.B
SOL.A
Station 11
SOL.B
SOL.A
Station 12
(Max.)
SOL.B
COM.
COM.
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Positive
COM spec.
Metal seal
Rubber seal
Caution
Use the standard (DC)
specification when continuously
energizing for long periods of
time.
Enclosure
IP65 (Dust-tight,
Water-jet-proof)
Manual override
Nil
B
C
D
Negative
ta
External
pilot
R Note 3)
tio
N Note 3) common
High-speed (0.95 W)
response type
Note 1)
VV5Q21-09C6M2-W
VQ2100-51
VQ2200-51
VQ2300-51
VVQ2000-10A-1
Light/surge voltage
suppressor
Nil
Yes
None
Coil voltage
1
3
5
6
0
1
Standard
CE compliant
sid
Seal
(0.4 W)
Nil
AC
2-position single
1
2-position double
2
3-position closed center
3
3-position exhaust center
4
3-position pressure center
5
A 4-position dual port (N.C. +N.C.)
B 4-position dual port (N.O. +N.O.)
C 4-position dual port (N.C. +N.O.)
DC
sid
Nil
Function
Symbol Specifications
<Example>
Circular connector kit with cable (3 m)
CE compliant
VQ2000
Type of actuation
W1
Series
2
ns
Negative
COM spec.
VQ 2 1 0 0
[Option]
None
None
None
None
None
None
None
White
Black
Black
Red
Red
Red
Black
Black
White
None
None
Black
White
White
Red
Red
White
None
None
Dot marking
Black
Brown
Red
Orange
Yellow
Pink
Blue
Purple
Gray
White
White
Yellow
Orange
Yellow
Pink
Blue
Purple
Gray
Orange
Red
Brown
Pink
Gray
Black
White
White
CE compliant
3m
52
G kit
T kit
SOL.A
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
Note) ()
()
L kit
SOL.B
Polarity
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
(+)
(+)
S kit
Station 1
M kit
Terminal no.
SOL.A
Sub-plate
Single Unit
015
AXT100-MC26- 030 Wire color
050
Semistandard
Construction
Wiring Specifications
Exploded
View of
Manifold
Electrical
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
sid
e
S
ta
tio
ns
J kit
sid
e
P kit
F kit
VQ-A.qxd
09.2.26 2:36 PM
Page 54
Series VQ2000
kit (Circular connector)
VV5Q21
< >: AC
The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].
(L4)
(L3)
L2
L1
(5.25)
34.5
1
59
73.5 <77.5>
29.5
Indicator light
Manual
override
6.5
4 x M5
mounting hole
(12)
(35)
10.6
4
46.2
22
120 <126.9>
80
(5.5)
0.9
13
73.7
D side
Stations
U side
EXH
EXH
49
31.6
24.5
16
47
65
Dimensions
n
L1
L2
(L3)
(L4)
53
(7.5)
9.5
(12)
10
11
12
109.5
125.5
141.5
157.5
173.5
189.5
205.5
221.5
237.5
253.5
269.5
132.5
148.5
164.5
180.5
196.5
212.5
228.5
244.5
260.5
276.5
292.5
162.5
175
187.5
200
225
237.5
250
275
287.5
300
312.5
173
185.5
198
210.5
235.5
248
260.5
285.5
298
310.5
323
VQ2 1 0 0
+ Sub-plate
5 W 1
J kit
Valve
02
CE compliant
Nil
T kit
Enclosure
Nil
CE compliant
Thread type
Dust-protected
Nil
Rc
NPT
NPTF
Port size
02
1/4
S kit
L kit
VQ2000 PW 02
M kit
Terminal
block
G kit
In the case of
P kit
How to Order
IP65 enclosure in
standard specifications
F kit
Series VQ2000
Dimensions
4
Sub-plate
Single Unit
89.4
(43.8)
2 x 4.5
(Mounting hole)
10.5
(A port)
Manual override
10.5
(B port)
Semistandard
Construction
VQ210 01 -1-02
45
37
Indicator light
121 <127.9>
Exploded
View of
Manifold
22.4
15.5
77.2
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Clamp screw
70.7
72.7 <76.7>
M5 x 0.8
External pilot port
R1
R2 3
25
12
15.4
25
2.5
G 3/8
Electrical entry
14.5
19.5
39.1
53.6
12
20
(A, B port)
25
43.8
5 x 1/4"
1(P), 4(A), 2(B), 5(R1), 3(R2) port
< >: AC
Note) When using this valve for IP65, mount a seal connector to the electrical entry.
54
VQ-A.qxd
09.2.26 2:36 PM
Page 56
Series VQ1000/2000
Semi-standard
VV5Q11
VV5Q11
06 C6 F SA
06 C6 P SC
Option
Option
Stations
Stations
Cylinder port
Cylinder port
How to Order
How to Order
Location
Pins
Top entry
F kit
Side entry
UA
F kit
SA
In the same way as the 25-pin models (standard), the terminal no. 1 is for
SOL.A at the 1st station, the terminal no. 9 for SOL.B at the 1st station, and
the terminal no. 8 for COM.
Multi-core vinyl cable
Wire Color Table by Terminal No. of
VVRF 0.3 mm2 x 15
D-sub Connector Cable Assembly
9 cores
Plug connector
HDA-CTH
(Made by Hirose Electric)
Connector
HAD-15S
(Made by Hirose Electric)
2 x M2.6 X 0.45
Terminal no.
Pins
15P
Top entry
P
kit
Side entry
UA
UB
UC
P
kit
SA
SB
SC
In the same way as the 26-pin models (standard), the terminal no. 1 is for
SOL.A at the 1st station, the terminal no. 2 for SOL.B at the 1st station, and
two pins from the max. terminal numbers are for COM.
Red
10P
16P
20P
1.5 m
AXT100-FC10-1
AXT100-FC16-1
AXT100-FC20-1
1.5 m
AXT100-DS15-1
3m
AXT100-FC10-2
AXT100-FC16-2
AXT100-FC20-2
3m
AXT100-DS15-2
5m
AXT100-FC10-3
AXT100-FC16-3
AXT100-FC20-3
5m
AXT100-DS15-3
17.2
24.8
30
55
Location
Pins
Terminal no.
For other commercial connectors, use a type with strain relief conforming
to MIL-C-83503.
Page 3
Series VQ1000/2000
F kit
1. How to Order
Indicate an option symbol -K, for the manifold no. and be
sure to specify the mounting position and number of stations
of the single and double wiring by means of the manifold
specification sheet.
VQ1100 N
VV5Q11 08C6FU1 D K S
51
G kit
Example)
P kit
10.11.29 11:32 AM
J kit
311-VQ-CT.qxd
2. Wiring specifications
T kit (VQ1000):
17
18
21
6
9
1st
row
Cylinder port
Sub-plate
Single Unit
J/G kit
2nd
row
Negative common
specifications
10
3rd
row
19
20
M kit
T kit
T kit
Terminal block Terminal block
(VQ1000, 24 terminals)
(VQ2000)
Stations
L kit (VQ1000/2000):
Type
Max.
points
F kit (D-sub
connector)
F US F US A P US P US C P US B P US A
25P 15P 26P 20P 16P 10P
24
VQ1000
VQ2000
Max.
points
14
24
18
14
T kit
(Terminal block box)
Kit
Type
P kit
(Flat ribbon cable)
2 rows of
3 rows of
terminal blocks terminal blocks
16
J kit (Flat
G kit (Flat ribbon cable
ribbon cable) with terminal block)
J US
20P
16
16
M kit
S kit
(Serial transmission) (Circular connector)
16
24
Semistandard
06 C6 L N 1
Stations
Construction
Kit
VV5Q11
Cylinder port
Negative common
specifications
Exploded
View of
Manifold
Electrical entry
Cable length
0
1
2
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
24
20
M kit
26
22
11
L kit
25
23
12
Option
16
24
06 C6 T N
COM.
15
14
13
VV5Q11
S kit
F kit
P kit
D-sub connector
Flat ribbon
(25P)
cable connector
(26P)
T kit
Option
56
VQ-A.qxd
09.2.26 2:36 PM
Page 58
Series VQ1000/2000
Semi-standard
When the supply air pressure is lower than the required minimum
operating pressure (0.1 to 0.2 MPa) for the solenoid valve (or
when the valve is used for vacuum), specify an external pilot
model. Order a manifold or valve by suffixing the external pilot
specification, R. The X-port of the manifold base is equipped
with one-touch fittings for external pilot.
VQ1000: C4 (4 one-touch fitting)
VQ2000: C6 (6 one-touch fitting)
Example)
VV5Q11 08C6FU1 D0 S
VV5Q11 08C6FU1 R S
Example)
VQ1100 R
VV5Q11 08C6FU1 D 09 S
51
Note 1) When two or more functions are specified, indicate them alphabetically.
Note 2) Since the pilot EXH of this valve is released from the R1 passage, it is not
possible to vacuum from a part other than EXH pressure and SUP ports.
The number of stations that may be displayed is longer than the manifold
number of stations.
VV5Q11
06 N7 PS0
Stations
Option
Kit type/Electrical entry
Cylinder port
Symbol
N1
N3
N7
N9
M5T
NM
1/8"
5/32"
1/4"
5/16"
10-32UNF
(M5 thread)
Mixed
4(A), 2(B)
port
(Pitch)
VQ1000
VQ2000
Note) When inch-size fittings are selected for the cylinder port, inch-size fittings are
selected on 1(P), 3(R) port, too.
57
L Dimension
L = 12.5 x n + 10.5
No.
10
L dimension
23
35.5
48
60.5
73
85.5
98
110.5
123
135.5
No.
11
12
13
14
15
16
17
18
19
20
L dimension
148
160.5
173
185.5
198
210.5
223
235.5
248
260.5
No.
21
22
23
24
25
26
27
28
29
30
L dimension
273
285.5
298
310.5
323
335.5
348
360.5
373
385.5
No.
31
32
33
34
35
36
37
38
39
40
L dimension
398
410.5
423
435.5
448
460.5
473
485.5
498
510.5
Exploded
View of
Manifold
Construction
Semistandard
Sub-plate
Single Unit
M kit
S kit
L kit
T kit
G kit
J kit
P kit
F kit
09.2.26 2:36 PM
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
VQ-A.qxd
Page 59
58
VQ-A.qxd
09.2.26 2:36 PM
Page 60
Series VQ1000/2000
Construction
VQ1000 Plug-in Unit: Main Parts/Replacement Parts
Metal seal
Rubber seal
eqw
VQ1100
eqw
VQ1101
(A) (B)
4 2
r
5 1 3
(R1) (P)(R2)
5 1 3
(R1) (P)(R2)
eqw
eqw
VQ1200
VQ1201
(A) (B)
4 2
5 1 3
(R1) (P)(R2)
(A) (B)
4 2
5 1 3
(R1) (P)(R2)
r
eqw
VQ1300
(A) (B)
4 2
eq
VQ1500
VQ1301
5 1 3
(R1) (P)(R2)
(A) (B)
4 2
4 2
(A) (B)
4 2
5 1 3
(R1) (P)(R2)
5 1 3
(R1) (P)(R2)
(A) (B)
4 2
VQ1501
5 1 3
(R1) (P)(R2)
4 2
5 1 3
(R1) (P)(R2)
(A) (B)
4 2
5 1 3
(R1) (P)(R2)
eq
VQ1A01
VQ1B01
4
(A)
5
(R1)
2
(B)
1
(P)
VQ1C01
4
(A)
5
(R1)
Component Parts
No.
1
2
3
4
Description
Body
Spool/Sleeve
Piston
Pilot valve assembly
5
(R1)
2
(B)
1
(P)
3
(R2)
2
(B)
1
(P)
3
(R2)
Component Parts
Material
Zinc die-casted
Stainless steel
Resin
Note
59
3
(R2)
4
(A)
No.
1
2
3
4
Description
Body
Spool valve
Piston
Pilot valve assembly
Material
Zinc die-casted
Aluminum, HNBR
Resin
Note
VQ-A.qxd
09.2.26 2:36 PM
Page 61
Series VQ1000/2000
Metal seal
F kit
VQ2101
(A) (B)
4 2
(A) (B)
4 2
5 1 3
(R1) (P)(R2)
5 1 3
(R1) (P)(R2)
T kit
G kit
VQ2100
J kit
P kit
VQ2201
5 1 3
(R1) (P)(R2)
5 1 3
(R1) (P)(R2)
r
e
M kit
(A) (B)
4 2
L kit
(A) (B)
4 2
S kit
VQ2200
VQ2501
5 1 3
(R1) (P)(R2)
(A) (B)
4 2
5 1 3
(R1) (P)(R2)
VQ2A01
4
(A)
5
(R1)
2
(B)
1
(P)
VQ2C01
4
(A)
5
(R1)
Component Parts
No.
1
2
3
4
Description
Body
Spool/Sleeve
Piston
Pilot valve assembly
5 1 3
(R1) (P)(R2)
5 1 3
(R1) (P)(R2)
(A) (B)
4 2
4 2
Sub-plate
Single Unit
5 1 3
(R1) (P)(R2)
(A) (B)
4 2
Semistandard
VQ2500
4 2
Construction
5 1 3
(R1) (P)(R2)
VQ2301
VQ2B01
3
(R2)
4
(A)
5
(R1)
Exploded
View of
Manifold
(A) (B)
4 2
2
(B)
1
(P)
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
VQ2300
3
(R2)
2
(B)
1
(P)
3
(R2)
Component Parts
Material
Zinc die-casted
Stainless steel
Resin
Note
No.
1
2
3
4
Description
Body
Spool valve
Piston
Pilot valve assembly
Material
Zinc die-casted
Aluminum, HNBR
Resin
Note
60
225-VQ-CT.qxd
10.10.7 5:14 PM
Page 1
S kit
P/J kit
!5
w
o
r
!0
!4
25 pins
(Top entry)
(Integral
housing type)
!1
F kit
!3
15 pins
(Upward side
entry)
25 pins
(Side entry)
!2
L kit
t
61
F kit
P kit
Nil
Option
Nil
R Note 1)
S Note 1)
R
S
Common EXH
External pilot
Direct EXH outlet with
built-in silencer
F0
F1
F2
F3
P1
P2
P3
L0
L1
L2
<Fitting Assembly>
!3 Fitting assembly part no. (For cylinder port)
VVQ1000-50A-
C3
C4
C6
M5
Part no.
VVQ1000-80A-1
VVQ1000-80A-2
VVQ1000-80A-3
VVQ1000-80A-4
Description
Gasket
Packing
Clamp screw
Clip
Port size
C3
C4
C6
M5
VVQ1000-51A-C8
Applicable tubing 8
Note) Purchasing order is available
in units of 10 pieces.
VVQ1000-TR-
Replacement Parts
o
!0
!1
!2
J kit
VVQ1000-2A-1-L
G kit
Port size
Electrical entry
T kit
Common EXH
External pilot
Direct EXH outlet with built-in silencer
M kit
VVQ1000-1A-
Option
Sub-plate
Single Unit
Electrical entry
FU25
F
P
L
S
VVQ1000-2A-1-
L kit
VVQ1000-3A-1-
S kit
Note 1) Top entry connector for PU, JU while side entry connector for PS, JS.
Note 2) Suffix -XP to the end of the part number for dust-protected SI unit. (Not available for S/SQ kit)
Semistandard
Description
NKE Corp.: Uni-wire System (16 outputs)
NKE Corp.: Uni-wire H System (16 outputs)
Panasonic Electric Works SUNX Co., Ltd.: S-LINK System (16 outputs)
Panasonic Electric Works SUNX Co., Ltd.: S-LINK System (8 outputs)
DeviceNet
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
Flat ribbon cable housing assembly = Number of pins: 26/20/16/10
Flat ribbon cable housing assembly
D-sub connector housing assembly (Top entry) Number of pins: 15
D-sub connector housing assembly (Side entry) = Number of pins: 25/15
Construction
Part no.
EX120-SUW1(-XP) Note 2)
EX120-SUH1(-XP) Note 2)
EX120-SSL1(-XP) Note 2)
EX120-SSL2(-XP) Note 2)
EX120-SDN1
EX120-SCS1(-XP) Note 2)
EX120-SCS2(-XP) Note 2)
EX120-SMJ1(-XP) Note 2)
AXT100-1-P US Note 1)
AXT100-1-J US 20 Note 1)
AXT100-1-FU15
AXT100-1-FS
Exploded
View of
Manifold
Manifold
(SF1 kit)
(SH kit)
(SJ1 kit)
(SJ2 kit)
(SQ kit)
(SR1 kit)
(SR2 kit)
(SV kit)
PUS kit
J US kit
FU kit
FS kit
Material
Quantity
HNBR
12
HNBR
12
Carbon steel
12
Stainless steel
12
V112
Coil voltage
Function
Symbol Specifications
Nil
B
K
Standard
DC
(0.4 W)
High-speed (0.95 W)
response type
High-pressure type (0.95 W)
(1.0 MPa)
AC
Note 1)
1
2
3
4
5
6
Enclosure
Dust-tight,
A Water-jet-proof
(IP65)
B Dust-protected
62
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
No.
VQ-A.qxd
09.2.26 2:36 PM
Page 64
S kit
Housing assembly
and SI unit
q
!3
P/J kit
!0
u
!5
F kit
!2
!1
!6
!4
G kit
L kit
y
63
F kit
P kit
J kit
G kit
e
r
Note 1) Suffix -XP to the end of the part number for dust-protected SI unit.
Note 2) Dust-tight, Water-jet-proof (IP65)
Note 3) Top entry connector for FU, PU, JU while side entry connector for FS, PS, JS.
VVQ2000-3A-1-
VVQ2000-2A-1R
Option
Nil
R Note 1)
S Note 1)
Nil
VVQ2000-2A-1-LEnclosure
Nil
VVQ2000-1A-
Electrical entry
F0
F1
F2
F3
P1
P2
P3
L0
L1
L2
T1
T3
M1
M2
M3
C4
C6
C8
C0
Dust-protected
Dust-tight, Water-jet-proof (IP65)
Port size
Dust-protected
Dust-tight, Water-jet-proof (IP65)
Common EXH
External pilot
Direct EXH outlet with built-in silencer
Enclosure
Common EXH
External pilot
Direct EXH outlet
with built-in silencer
M kit
Nil
L kit
Dust-protected
Dust-tight, Water-jet-proof (IP65)
Enclosure
Nil
Semistandard
Nil
For F kit
For G/J/P kit
For L kit
For S kit
Dust-protected
Dust-tight, Water-jet-proof (IP65)
<Fitting Assembly>
!44 Fitting assembly part no. (For cylinder port)
VVQ1000-51A-
Exploded
View of
Manifold
F
P
L
S
Option
Enclosure
Construction
Electrical entry
Port size
C4 Applicable tubing 4
C6 Applicable tubing 6
C8 Applicable tubing 8
Part no.
!0
!1
!2
!3
VVQ2000-80A-1
VVQ2000-80A-2
VVQ2000-80A-3
VVQ2000-80A-4
Description
Gasket
Seal
Clamp screw
Clip
Material
Quantity
HNBR
12
HNBR
12
Carbon steel
12
Stainless steel
12
VVQ2000-51A-C10
Applicable tubing 10
Note) Purchasing order is available
in units of 10 pieces.
VVQ2000-TR-
T kit
Description
NKE Corp.: Uni-wire System (16 outputs)
NKE Corp.: Uni-wire H System (16 outputs)
Panasonic Electric Works SUNX Co., Ltd.: S-LINK System (16 outputs)
Panasonic Electric Works SUNX Co., Ltd.: S-LINK System (8 outputs)
DeviceNet
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
Flat ribbon cable housing assembly : Number of pins: 26/20/16/10
Flat ribbon cable housing assembly
D-sub connector housing assembly : Number of pins: 25/15
Flat ribbon cable housing assembly with terminal block
S kit
Part no.
EX120-SUW1(-XP) Note 1) [EX123D-SUW1] Note 2)
EX120-SUH1(-XP) Note 1) [EX123D-SUH1] Note 2)
EX120-SSL1(-XP) Note 1) [EX123D-SSL1] Note 2)
EX120-SSL2(-XP) Note 1) [EX123D-SSL2] Note 2)
EX120-SDN1 [EX124D-SDN1] Note 2)
EX120-SCS1(-XP) Note 1) [EX124D-SCS1] Note 2)
EX120-SCS2(-XP) Note 1) [EX124D-SCS2] Note 2)
EX120-SMJ1(-XP) Note 1) [EX124D-SMJ1] Note 2)
AXT100-1-PUS Note 3)
AXT100-1-J US20 Note 3)
AXT100-1-F US Note 3)
AXT100-1-GU20
Sub-plate
Single Unit
Manifold
(SF1 kit)
(SH1 kit)
(SJ1 kit)
(SJ2 kit)
(SQ kit)
(SR1 kit)
(SR2 kit)
(SV kit)
P US kit
J US kit
FUS kit
G kit
64
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
No.
VQ-A.qxd
09.2.26 2:36 PM
Page 66
Series VQ1000
VQ1000: Manifold Optional Parts
Blanking plate assembly
VVQ1000-10A-1
JIS symbol
Valve
U side
ide
Ds
C6 (EXH port)
C6: 6 one-touch fitting
Single
EXH block
base assembly
EXH
passage
blocked
Stations
Description/Model
Valve
Valve
D side
Option
When the same manifold is to be used for different pressures, individual SUP spacers are used as SUP ports for
different pressures. (One station space is occupied.)
Block both sides of the station, for which the supply
pressure from the individual SUP spacer is used, with
SUP block plates. (Refer to the application example.)
Specify the spacer mounting position and SUP block plate
position by means of the manifold specification sheet.
The block plate is used in one or two places for one set.
(Two SUP block plates for blocking SUP station are
attached to the individual SUP spacer.)
As a standard, electric wiring is connected to the position of the
manifold station where the individual SUP spacer is mounted.
If wiring is not required for stations equipped with
spacers, enter X in the special wiring specifications
column in the manifold specification sheet.
C6 (SUP port)
C6: 6 one-touch fitting
D side
Valve
Valve
+
EXH block base assembly
(Not to be
ordered)
Valve
(Not to be
ordered)
U side
ide
Us
Nil
1
2
Connector
Without connector
With connector/2-wire
With connector/4-wire
JIS symbol
65
Connector
assembly
Lead wire
length (mm)
AC
43 4-wire
44 2-wire
24AWG
Cover O.D. 1.5
Power
supply side
Blanking
plate side
Indication labels to confirm the blocking position are attached (Each for SUP passage and SUP/EXH passage
blocking positions).
When ordering a block plate incorporated with a
manifold, a block indication label is attached to the
manifold.
Nil
6
10
20
30
300
600
1000
2000
3000
09.2.26 2:36 PM
Page 67
Black screw
U side
ide
Us
EXH
passage blocked
P kit
EXH block
base assembly
D side
ide
Ds
J kit
Solid forming
G kit
F0
F1
F2
F3
P1
P2
P3
L0
L1
L2
Series VQ1000
F kit
VQ-A.qxd
L kit
2 pcs. in 1 set
(Precautions)
1. The back pressure check valve assembly is the parts with a check
valve structure. However, since the
valve has slight air leakage, take
precautions for the exhaust air not
to be restricted at the exhaust port.
2. When a back pressure check valve
is mounted, the effective area of
the valve will decrease by about
20%.
9
KQ2P-
It is inserted into an unused cylinder port
and SUP/EXH ports.
Purchasing order is available in units of 10
pieces.
n: Stations
Semistandard
Note) ( ): VVQ1000-NC-n
Dimensions
Applicable
fitting size
d
3.2
4
6
8
Model
KQ2P-23
KQ2P-04
KQ2P-06
KQ2P-08
16
16
18
20.5
31.5 3.2
32
6
35
8
39 10
Applicable
fitting size
d
1/8"
5/32"
1/4"
5/16"
Model
KQ2P-01
KQ2P-03
KQ2P-07
KQ2P-09
16
16
18
20.5
31.5 5
32
6
35 8.5
39 10
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Port plug
VVQ0000-58A
Hole
40
13.5
Downward
Construction
Sub-plate
Single Unit
P = 10.5
N: Standard
NC: For mounting
blanking plate
with connector
Exploded
View of
Manifold
It is a transparent resin plate for placing a label that indicates solenoid valve function, etc.
Insert it into the groove on the side of the end plate
and bend it as shown in the figure.
When the blanking plate with connector is mounted, it
automatically will be VVQ1000-NC-n
When ordering this option incorporated with a manifold, suffix -N to the end of the manifold part number.
S kit
M kit
Indication labels to confirm the blocking position are attached. (Each for EXH passage and SUP/EXH passage
blocking positions)
When ordering a EXH block base incorporated with a manifold, a block indication label is attached to the manifold.
T kit
Upward
66
VQ-A.qxd
09.2.26 2:36 PM
Page 68
Series VQ1000
VQ1000: Manifold Optional Parts
DIN rail mounting bracket [-D/-D0/-D]
VVQ1000-57A
It is used for mounting a manifold on a DIN rail.
When ordering this option incorporated with a manifold, suffix D to the end of the manifold part number.
1 set of DIN rail mounting bracket is used for 1 manifold
(2 DIN rail mounting brackets).
Exhaust
Dimensions
Series
Applicable
fitting size
d
VQ1000
How to Order
Regulator unit
VVQ1000-AR-1
The regulator controls the SUP pressure in a manifold.
Supply air from D-side SUP port is regulated. SUP port
on U-side is plugged.
When a regulator unit is mounted, the SUP port on the
U-side of the manifold will be plugged. A maximum of 3
units can be mounted on a manifold.
Specifications
0.8
Maximum operating pressure (MPa)
0.05 to 0.7
Set pressure range (MPa)
5 to 50
Ambient and fluid temp. (C)
Air
Fluid
0.02
Cracking pressure valve (MPa)
Relieving type
Structure
Pressure gauge
G27-10-01
AN200-KM8
59
78
22
20
AN203-KM8
32
51
16
14
(mm2)
Number of
regulator units 2 sets
(dB)
30
25
Conditions:
Inlet pressure 0.7 MPa
Pressure
Characteristics
Flow Characteristics
Pressure
control screw
Effective Noise
area reduction
Model
This silencer is to be inserted into the EXH port (onetouch fittings) of the common exhaust type.
When mounting elbow fitting assembly (VVQ1000-FL) on the edge of manifold station, select a silencer,
AN203-KM8. A silencer (AN200-KM8) is interfered with
fittings.
31.5
Initial setting
value
+
SMC
102
SUP port on
U-side is plugged.
VVQ1000-AR-1
C8 (SUP) port
8 one-touch fitting
D side
Regulator unit
Valve
Caution
U side
SMC
78
63.5
Pressure setting
Check the inlet pressure and then turn the pressure control screw to
set the outlet pressure. Turning the screw clockwise will increase the
outlet pressure while turning it counterclockwise decrease the pressure. (Set the pressure by turning the screw in the increase direction.)
Counted as
one station.
67
Installation
Since some level of the actuators operational frequency may lead to a
sharp pressure change, pay attention to the pressure gauge durability.
Page 69
F kit
Series VQ1000
<Circuit diagram>
J kit
P kit
09.2.26 2:36 PM
Specifications
Max. operating pressure
Min. operating pressure
Ambient and fluid temp.
Flow characteristics: C
Max. operating frequency
0.8 MPa
0.15 MPa
5 to 50C
0.60 dm3/(sbar)
180 c.p.m
VVQ1000-FPG-02 1 set
VQ1000-FPG-C6M5-D 2 pcs.
G kit
VQ-A.qxd
Single unit
T kit
Dimensions
Manifold
L kit
2n x C4, C6
C4: 4 one-touch fitting
C6: 6 one-touch fitting
2 x C4, C6
C4: 4 one-touch fitting
C6: 6 one-touch fitting
Dimensions
n
L1
L2
L3
n
L1
L2
L3
How to Order
Formula L1 = 11n + 20
31
42
53
64
75
86
97
108
119
50
62.5 75
112.5 125
125
137.5 150
87.5 100
60.5 73
85.5 98
13
15
163
14
174
185
198
16
196
110.5 123
17
207
212.5 225
210.5 223
18
218
19
20
21
10
130
22
240
251
237.5 250
250
262.5 275
262
12
152
185.5
23
273
24
284
287.5 300
285.5 298
310.5
<Example>
C4 M5
M5 thread
3.2 one-touch fitting
4 one-touch fitting
6 one-touch fitting
5/32" one-touch fitting
1/4" one-touch fitting
M5 thread
3.2 one-touch fitting
4 one-touch fitting
6 one-touch fitting
5/32" one-touch fitting
1/4" one-touch fitting
VVQ1000 FPG
2-position
06
Stations
Option
Nil
F
D
N
3-position
exhaust center
Exploded
View of
Manifold
VQ1000 FPG
U side
162.5 175
160.5 173
229
235.5 248
11
141
Stations 1 2 3
Semistandard
D side
Construction
None
With bracket
DIN rail mounting
(For manifold)
Name plate
Note) When two or more symbols are specified, indicate them alphabetically.
Example) -DN
Drop
prevention
Intermediate
stops
Caution
Air leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder from
stopping for long periods of time. Check the leakage using neutral household detergent, such as dish
1 station
01
washing soap. Also check the cylinders tube gasket, piston packing and rod packing for air leakage.
Since one-touch fittings allow slight air leakage, screw piping (with M5 thread) is recommended when
stopping the cylinder in the middle for long periods of time.
<Ordering example>
16 16 stations
Combining double check block with 3-position closed center or pressure center solenoid valve will not work.
VVQ1000-FPG-06...6-station manifold
M5 fitting assembly is attached, not incorporated into the double check block. After screwing in the M5
VQ1000-FPGBracket Assembly
fittings, mount the assembly on the double check block. {Tightening torque: 0.8 to 1.2 Nm}
C4M5-D, 3 sets Double
Part no.
Tightening torque If the exhaust of the double check block is restricted too much, the cylinder may not operate properly and
check block
VQ1000-FPGmay not stop intermediately.
VQ1000-FPG-FB 0.22 to 0.25 Nm Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.
C6M5-D, 3 sets
68
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Residual pressure
release manual
override
Sub-plate
Single Unit
M kit
M2.5 mounting
hole
S kit
M3 mounting hole
VQ-A.qxd
09.2.26 2:36 PM
Page 70
Series VQ1000
VQ1000: Manifold Option/With Ejector Unit
An ejector unit can be mounted on the manifold base for a solenoid valve.
Instead of mounting the valve and ejector unit separately, this option
reduces piping, wiring and creates additional space savings.
SET
U side
4
1
2
3
4
3
2
3
2
1
D side
Specifications
VVQ1000-J-1-A VVQ1000-J-1-B
0.7
11
1.0
20
630
0.5
5 to 50
Max. number of
ejector units
F, P, T kit
S, G, J kit
L kit
11 (20)
7 (14)
10 (16)
6 (12)
9 (12)
5 (10)
8 (8)
4 (8)
4 (4)
3 (4)
Dimensions
A
B
Indicator light
Restrictor
(Release flow
adjustment)
Air supply
valve
SET
63
HYS
Vacuum
release valve
37.2
How to Order
VV5Q11 05C6FUO J P 1 S
Vacuum switch
Nil
None
With
Number of ejectors
1 to 5
69
Example)
VV5Q11-05C6FUO-JP1 ...... 1 setManifold part no.
Page 1
Series VQ1000
VVQ1000
J 1
5 C 1
F kit
A
Specifications
Function
B
Nil
B
K
N
Standard
DC
(0.4 W)
AC
Coil voltage
Note 1)
1
2
3
4
5
6
High-speed (0.95 W)
response type
High-pressure type (0.95 W)
(0.8 MPa)
Negative
common
Manual override
Nil
B
C
D
Manifold
1
G kit
Symbol Specifications
P kit
10.1.14 2:22 PM
J kit
VQ-A.qxd
Plug-in unit
Wiring specifications
Nil
L
C
CL
CN
30
50
L kit
0.6
3
5
M kit
14
15
16
17
18
19
(The flow characteristics are for the supply pressure of 0.5 MPa.)
Flow Characteristics
Semistandard
Construction
Exploded
View of
Manifold
Flow Characteristics
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Vacuum pressure
Air consumption
Vacuum pressure
Air consumption
S kit
T kit
15 CL
Sub-plate
Single Unit
ZSE1 00
70
VQ-A.qxd
09.2.26 2:37 PM
Page 72
Series VQ2000
VQ2000: Manifold Optional Parts
Blanking plate assembly JIS symbol
VVQ2000-10A-1
It is used by attaching on the manifold block for being
prepared for removing a valve for maintenance reasons
or planning to mount a spare valve, etc.
D side
Valve
Individual Valve
SUP spacer
Valve
U side
ide
Us
ide
Ds
Valve
Individual Valve
EXH spacer
Valve
U side
C8 (EXH port)
C8: 8 one-touch fitting
ide
EXH block
plate
Us
ide
D s Block indication label
A label indicating the EXH passage
blocking position is to be adhered.
ide
Us
ide
Ds
ide
Us
2 pcs. in 1 set
ide
Ds
71
VQ-A.qxd
09.2.26 2:37 PM
Page 73
Series VQ2000
F kit
15.8
92.5
PUSH
J kit
LOCK
1
(P)
G kit
9.6
21.5
26.8
P kit
78.8
4(A)
Single valve
T kit
2(B)
L kit
5 3
(R1) (R2)
Semistandard
P = 16
KQ2P-
It is inserted into an unused
cylinder port and SUP/EXH ports.
Purchasing order is available in
units of 10 pieces.
Construction
n: Stations
Exploded
View of
Manifold
Sub-plate
Single Unit
(Precautions)
M kit
2 pcs. in 1 set
Dimensions
Applicable
fitting size
d
Model
Applicable
fitting size
d
Model
4
6
8
10
KQ2P-04
KQ2P-06
KQ2P-08
KQ2P-10
16
18
20.5
22
32
35
39
43
6
8
10
12
5/32"
1/4"
5/16"
3/8"
KQ2P-03
KQ2P-07
KQ2P-09
KQ2P-11
16
18
20.5
22
32
35
39
43
6
8.5
10
11.5
Port plug
VVQ1000-58A
The plug is used to block the cylinder port.
When ordering a plug incorporated with a manifold,
indicate CM for the port size of the manifold part
number, as well as, the mounting position and number of stations and cylinder port mounting positions, A
and B by means of the manifold specification sheet.
72
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
S kit
<Circuit diagram>
(Example of a spacer
with a built-in single valve)
VQ-A.qxd
09.2.26 2:37 PM
Page 74
Series VQ2000
VQ2000: Manifold Optional Parts
DIN rail mounting bracket [-D/-D0/-D]
VVQ2000-57A
It is used for mounting a manifold on a DIN rail.
When ordering this option incorporated with a manifold, suffix -D to the end of the manifold part number.
Dimensions
Series
VQ2000
Effective
Applicable
fitting size
d
Model
10
AN200-KM10
59.6 80.8
Noise
(Cv factor)
(dB)
26 (1.4)
30
73
VQ-A.qxd
09.2.26 2:37 PM
Page 75
Series VQ2000
Manifold Option
F kit
VQ2000-FPG--
It is mounted on the outlet side piping to keep the cylinder in the intermediate
position for a long time. Combining the double check block with a 3-position exhaust
center solenoid valve will enable the cylinder to stop in the middle or maintain its
position for long periods of time.
The combination with a 2-position single/double solenoid valve will prevent the
dropping at the cylinder stroke end when the SUP residual pressure is released.
IN
P kit
Cylinder side
pressure (P2)
IN
Specifications
0.8 MPa
0.15 MPa
5 to 50C
3.0 dm3/(sbar)
180 c.p.m
To
CY
Lp
SUP side
pressure (P1)
ort
4
A
L kit
( 9.5)
3
Stations
D side
2 x Rc 1/8, 1/4, C6, C8
C6: 6 one-touch fitting assembly
C8: 8 one-touch fitting assembly
B
2
4
B
2
U side
M kit
58
(59.5)
B
2
25
45
65.5
20.5
9.5)
37.5
80
S kit
5.5
2
58
69.5
(5)
10.5
( 9.5)
39.5
80
6.5
(40)
IN
(For C6, C8)
Residual pressure
release manual
override
(41.5)
IN
(33)
IN
22
IN
( 9.5)
23 P = 22
2 x M6 mounting hole
Sub-plate
Single Unit
A
B
DIN rail
clamp screw
2 x M4 mounting hole
4
2
L3
L2
L1
G kit
25
45
4
A
Manifold
Single unit
17.5
(1.5)
37.5
Dimensions
L n
Formula L1 = 22n + 24
10
11
12
13
14
n: Station
15
Semistandard
Dimensions
(1.5)
16
90 112 134 156 178 200 222 244 266 288 310 332 354 376
L1 46 68
L2 75 87.5 112.5 137.5 162.5 175 200 225 250 262.5 287.5 312.5 337.5 362.5 375 400
L3 85.5 98 123 148 173 185.5 210.5 235.5 260.5 273 298 323 348 373 385.5 410.5
Construction
17.5
7.5
37.5
How to Order
Double check block
01
Rc 1/8
Rc 1/4
6 one-touch fitting
8 one-touch fitting
1/4" one-touch fitting
5/16" one-touch fitting
<Example>
Option
F
OUT side port size
01
02
C6
C8
N7
N9
Rc 1/8
Rc 1/4
6 one-touch fitting
8 one-touch fitting
1/4" one-touch fitting
5/16" one-touch fitting
None
F
N
With bracket
Name plate
Drop
prevention
Intermediate
stops
Caution
Nil
Exploded
View of
Manifold
VQ2000-FPG- 01
T kit
J kit
01
1 station
16 16 stations
<Ordering Example>
VVQ2000-FPG-06...6-station manifold
VQ2000-FPGBracket Assembly
C6C6-D, 3 sets
Double
Tightening torque
Part no.
VQ2000-FPG- check block
C8C8-D, 3 sets
VQ2000-FPG-FB 0.8 to 1.0 Nm
Air leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder from
stopping for long periods of time. Check the leakage using neutral household detergent, such as dish
washing soap. Also check the cylinders tube gasket, piston packing and rod packing for air leakage.
Since one-touch fittings allow slight air leakage, screw piping is recommended when stopping the cylinder in
the middle for long periods of time.
Combining double check block with 3-position closed center or pressure center solenoid valve will not work.
When fittings, etc. are being screwed to the double check block, tighten them with the torque below.
Connection threads
Rc 1/8
Rc 1/4
If the exhaust of the double check block is restricted too much, the cylinder may not operate properly and
may not stop intermediately.
Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.
74
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
VQ-A.qxd
09.2.26 2:37 PM
Page 76
Series VQ2000
Manifold Option
Double check block (Direct mounting)
VVQ2000-23A- BC 68
It is mounted directly on the manifold to keep the cylinder in the intermediate position
for a long time. Combining the double check block with a built-in pilot type double
check valve and a 3-position exhaust center solenoid valve will enable the cylinder to
stop in the middle or maintain its position for long periods of time.
The combination with a 2-position single/double solenoid valve will permit this block
to be used for preventing the dropping at the cylinder stroke end when the SUP
residual pressure is released.
Cylinder side
pressure (P2)
Specifications
Max. operating pressure
0.7 MPa
0.15 MPa
5 to 50C
SUP side
pressure (P1)
1.8 dm3/(sbar)
Flow characteristics: C
180 c.p.m
Dimensions
Single unit
15.8
180.2
80
180.2
120
20
120
55
65
15
22
10
85
<Recommended
hole dimension>
Color: red
Caution
Air leakage from the pipe between the valve and cylinder or from the fittings will
prevent the cylinder from stopping for long periods of time. Check the leakage using
neutral household detergent, such as dish washing soap.
Also check the cylinders tube gasket, piston packing and rod packing for air
leakage.
Since zero air leakage is not guaranteed, it is sometimes not possible to hold a stop
position for long periods of time.
Combining double check block with 3-position closed center or pressure center
solenoid valve will not work.
Set the cylinder load so that the cylinder pressure will be within two times that of
the supply pressure.
If the exhaust of the double check block is restricted too much, the cylinder may not
operate properly and may not stop intermediately.
<Example>
2-position
5(R1)
1(P)
3(R2)
Drop
prevention
5(R1)
1(P)
3(R2)
5(R1)
1(P)
3(R2)
Intermediate
prevention
2(B) 4(A)
75
2(B) 4(A)
VQ-A.qxd
09.2.26 2:37 PM
Page 77
VQ-A.qxd
09.2.26 2:37 PM
Page 78
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of Caution, Warning or
Danger. They are all important notes for safety and must be followed in addition to International
Standards (ISO/IEC), Japan Industrial Standards (JIS)1) and other safety regulations2).
1) ISO 4414: Pneumatic fluid power General rules relating to systems.
ISO 4413: Hydraulic fluid power General rules relating to systems.
IEC 60204-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements)
ISO 10218-1992: Manipulating industrial robots - Safety.
JIS B 8370: General rules for pneumatic equipment.
JIS B 8361: General rules for hydraulic equipment.
JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements)
JIS B 8433-1993: Manipulating industrial robots Safety.
etc.
2) Labor Safety and Sanitation Law, etc.
Caution:
Warning:
Danger :
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or
moderate injury.
Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or
serious injury.
Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious
injury.
Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment
or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be
decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results.
The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined
its compatibility with the product. This person should also continuously review all specifications of the product referring to its
latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the
equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or
equipment including our products must be performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or
runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power
from any appropriate source is cut, and read and understand the specific product precautions of all relevant products
carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to
be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military,
medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits,
clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard
specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective
function, and periodical checks to confirm proper operation.
Back page 1
F kit
Page 79
G kit
Caution
J kit
P kit
Safety Instructions
T kit
09.2.26 2:37 PM
L kit
VQ-A.qxd
Compliance Requirements
M kit
Sub-plate
Single Unit
Semistandard
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade
and Industry (Foreign Exchange and Foreign Trade Control Law).
Construction
Exploded
View of
Manifold
1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.3)
Also, the product may have specified durability, running distance or replacement parts. Please
consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility,
a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage
incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers
noted in the specified catalog for the particular products.
S kit
Back page 2
VQ-A.qxd
09.2.26 2:37 PM
Page 80
Series VQ1000/2000
Manual Override
Caution
Warning
Manual override:
Orange
(Drawing shows a VQ1000 case.)
Double solenoid
Indicator light
A: Orange
B: Green
VQ1000
Stop diode
Bore 3.2
Stop diode
Surge absorption
diode
Bore 4.2
VQ2000
Light
VQ2000
Double solenoid
VQ1000
Light
Surge absorption
diode
DC circuit diagram
Single solenoid
Bore 4.2
Single solenoid
Indicator light:
Orange
11 mm
Manual override:
Green
VQ1000
VQ2000
Caution
Do not apply excessive torque when turning the locking type manual
override. (0.1 Nm or less)
Back page 3
VQ-A.qxd
09.2.26 2:37 PM
Page 81
Series VQ1000/2000
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC
Products (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Warning
P kit
Manual Override
Caution
ON
Green
ON position
Caution
Dust on the sealing surface of the gasket or solenoid valve can cause
air leakage.
T kit
OFF
G kit
1. Press down on the clamp screw. Clamp bracket A opens. Diagonally insert the hook on the valve end plate side into clamp
B.
2. Press the valve body downward. (When the screw is released,
it will be locked by clamp bracket A.)
3. Tighten the clamp screw. (Proper tightening torque: VQ1000,
0.25 to 0.35 Nm; VQ2000, 0.5 to 0.7 Nm.)
J kit
Mounting
Bore 1.7
Orange
OFF position
F kit
VQ1000
Clip
Fitting assembly
Orange
OFF position
VQ2000
Fittings
assembly
The manual override is locked by sliding it all the way to the pilot
valve side (ON side) with a small flat head screwdriver or finger.
Slide it to the fitting side (OFF side) to release it. In addition, it
can also be used as a push type by using a screwdriver, etc., of
1.7 or less. (2 or less for VQ2000).
Caution
Clip
VQ1000
VQ2000
Fitting assembly part no.
VQ1000
VVQ1000-50A-C3
VVQ1000-50A-C4
VVQ1000-50A-C6
VVQ1000-50A-M5
VVQ1000-50A-N1
VVQ1000-50A-N3
VVQ1000-50A-N7
VQ2000
VVQ1000-51A-C4
VVQ1000-51A-C6
VVQ1000-51A-C8
VVQ1000-51A-N3
VVQ1000-51A-N7
VVQ1000-51A-N9
B
A
B
A
Refer to Manifold Optional Parts on pages 66, 67, 73 for other types of fittings.
Clamp bracket A
Clamp screw
Clamp bracket B
Removing
1. Loosen the clamp screw until it turns freely. (The screw is captive.)
2. Lift the coil side of the valve body while pressing down slightly
on the screw head and remove it from the clamp bracket B.
When the screw head cannot be pressed easily, gently press
the area near the manual override of the valve.
Caution
1. Use caution that O-rings must be free from scratches and dust. Otherwise, air leakage may result.
2. After screwing in the fittings, mount the M5 fitting assembly on the
manifold base. (Tightening torque: 0.8 to 1.2 Nm)
3. Purchasing order is available in units of 10 pieces.
Back page 4
M kit
Sub-plate
Single Unit
Green
ON
position
ON
Semistandard
OFF
Construction
Bore 2
The cylinder port fittings are a cassette for easy replacement. The fittings are blocked by a clip. Take out
the clip with a flat head screwdrier, etc., then replace
the fittings.
For mounting, insert the fitting assembly until it
strikes against the inside wall and then insert the clip
to the specified position.
Exploded
View of
Manifold
ON
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions
Caution
OFF
S kit
L kit
Bore 2
VQ-A.qxd
09.2.26 2:37 PM
Page 82
Series VQ1000/2000
Caution
Caution
A filter element is incorporated in the end plate on both sides of
the maifold base. A dirty and choked element may reduce cylinder speed or cause malfunction. Clean or replace the dirty element.
Removing
1. Loosen the clamp
screw on side (a)
of the end plate
on both sides.
2. Lift side (a) of the
manifold base and
slide the end plate
in the direction of
(2) shown in the
figure to remove.
Type
(2)
Built-in silencer,
direct exhaust
VQ1000
VQ2000
VVQ1000-82A-1
VVQ2000-82A-1
End plate
(1) (a)
Mounting
1. Hook side (b) of
the manifold base
on the DIN rail.
2. Press down side
(a) and mount the
end plate on the
DIN rail. Tighten
the clamp screw
on side (a) of the
end plate. The
proper tightening
torque for screws
is 0.4 to 0.6 Nm.
(b)
(1)
Hook
(2)
(a)
IP65 Enclosure
Caution
Wiring connection for models conforming to IP65 should also
have enclosures equivalent to or of stricter than IP65.
Back page 5
VQ-A.qxd
09.2.26 2:37 PM
Page 83
VQ-A.qxd
09.2.26 2:37 PM
Page 84
EUROPE
AUSTRIA
SMC Pneumatik GmbH (Austria)
BELGIUM
SMC Pneumatics N.V./S.A.
BULGARIA
SMC Industrial Automation Bulgaria Eood
CROATIA
SMC Industrijska Automatika d.o.o.
CZECH REPUBLIC
SMC Industrial Automation CZ s.r.o.
DENMARK
SMC Pneumatik A/S
ESTONIA
SMC Pneumatics Estonia O
FINLAND
SMC Pneumatics Finland Oy
FRANCE
SMC Pneumatique SA
GERMANY
SMC Pneumatik GmbH
GREECE
SMC Hellas E.P.E.
HUNGARY
SMC Hungary Ipari Automatizlsi Kft.
IRELAND
SMC Pneumatics (Ireland) Ltd.
ITALY
SMC Italia S.p.A.
LATVIA
SMC Pnuematics Latvia SIA
LITHUANIA
UAB SMC Pneumatics
NETHERLANDS
SMC Pneumatics B.V.
NORWAY
SMC Pneumatics Norway AS
POLAND
SMC Industrial Automation Polska Sp.z.o.o.
ROMANIA
SMC Romania S.r.l.
RUSSIA
SMC Pneumatik LLC
SLOVAKIA
SMC Priemyseln Automatizcia Spol s.r.o.
SLOVENIA
SMC Industrijska Avtomatika d.o.o.
SPAIN/PORTUGAL
SMC Espaa S.A.
SWEDEN
SMC Pneumatics Sweden AB
SWITZERLAND
SMC Pneumatik AG
U.K.
SMC Pneumatics (U.K.) Ltd.
ASIA
CHINA
SMC (China) Co., Ltd.
HONG KONG
SMC Pneumatics (Hong Kong) Ltd.
INDIA
SMC Pneumatics (India) Pvt. Ltd.
MALAYSIA
SMC Pneumatics (S.E.A.) Sdn. Bhd.
PHILIPPINES
Shoketsu SMC Corporation
SINGAPORE
SMC Pneumatics (S.E.A.) Pte. Ltd.
SOUTH KOREA
SMC Pneumatics Korea Co., Ltd.
TAIWAN
SMC Pneumatics (Taiwan) Co., Ltd.
THAILAND
SMC (Thailand) Ltd.
NORTH AMERICA
CANADA
SMC Pneumatics (Canada) Ltd.
MEXICO
SMC Corporation (Mexico), S.A. de C.V.
U.S.A.
SMC Corporation of America
SOUTH AMERICA
ARGENTINA
SMC Argentina S.A.
BOLIVIA
SMC Pneumatics Bolivia S.r.l.
BRAZIL
SMC Pneumticos do Brasil Ltda
CHILE
SMC Pneumatics (Chile) S.A.
VENEZUELA
SMC Neumatica Venezuela S.A.
OCEANIA
AUSTRALIA
SMC Pneumatics (Australia) Pty. Ltd.
NEW ZEALAND
SMC Pneumatics (N.Z.) Ltd.
Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.
D-DN
This catalog is printed on recycled paper with concern for the global environment.