Sie sind auf Seite 1von 13

1415 N 32nd, Fort Smith, AR 72904

Ph: 800-736-9089 Fax:479-785-0633

To: Engineers:

Thank you very much for your interest in our products and solutions. The purpose of this calculator is to
show the simplicity and ease of designing Terra Aqua Gabions gravity retaining walls. We are using the
familiar Excel environment to illustrate each step of the calculations used in the gabion gravity retaining
walls design analysis for verification.

Additional calculations may have to be performed including and not limiting to global stability
analysis (by Geotechnical Engineer), seismic forces (by Seismic Engineer) and hydraulic forces
(by Hydraulic Engineer). Please check local, State and Federal requirements. The calculator assumes
drained uniformed retained and foundation soil properties. The calculations should be reviewed, checked
and certified by a Professional Engineer. To the best of our knowledge, the calculator and information
was prepared accurately. Terra Aqua is not responsible for the reliability and validity of the geotechnical
parameters assumed in the calculations. The calculator is intended to provide design assistance to the
engineer for the purpose of designing with Terra Aqua products.

Please do not hesitate to contact us if you have any questions or if you are in need of any assistance.
We will assist you in anyway we can.

Colin Glass

Terra Aqua Gabions

5/30/2007
TERRA AQUA GABIONS GRAVITY RETAINING WALL CALCULATIONS
(STRAIGHT LINE BACK)
PROJECT NAME: PROJECT #:

LOCATION: SECTION:

GEOTECHNICAL ENGINEER: REPORT #:

NOTES: DRAWING #:

DATE:

Descriptions symbols Input Units Notes


Values

Backfill slope angle above wall 18.440 <


Angle of internal friction 28.000
Wall friction reduction by geotextile fr 20.000 % Back of wall
Angle of wall friction 22.400 (100-fr)/100
Inclination angle to vertical plane 6.000 for wall with straight back (no offsets)
Back of wall angle to horizontal 96.000 90+
Cohesion c 0 psf Ignore cohesion
Surcharge q 150.000 psf
Soil density s 125.000 pcf
Rock density r 138.000 pcf
Void in gabion v 30.000 %
Gabion density g 96.600 pcf r(100-v)/100
Actual height of wall H 11.934 ft (hCos) Corrected for inclination
Embedment d 3.000 ft 0 ft to ignore passive thrust
Width of base B 7.5 ft
Allowable soil bearing capacity qa 2000.000 psf determined by Geotechnical Engineer

45
GABION RETAINING WALL
ROW 1
42
ROW 2

39 ROW 3

ROW 4
36
ROW 5
33
ROW 6

X
30 Y ROW 7

27 ROW 8

ROW 9
24
ROW 10

21 ROW 11
Y

18 ROW 12

ROW 13
15
ROW 14
12
ROW 15

9 EMBEDMT

BACKFILL
6

-3
-3 0 3 6 9 12 15 18 21 24 27 30 33 36
-6
X
Row # Width Height offset Area X Moment Y Moment
(ft) (ft) (from toe) (ft) (ft) (ft) (ft) (ft) (ft)
15 0.000 0.000 0.000 0.000 0.000
14 0.000 0.000 0.000 0.000 0.000
13 0.000 0.000 0.000 0.000 0.000
12 0.000 0.000 0.000 0.000 0.000
11 0.000 0.000 0.000 0.000 0.000
10 0.000 0.000 0.000 0.000 0.000
9 0.000 0.000 0.000 0.000 0.000
8 0.000 0.000 0.000 0.000 0.000
7 0.000 0.000 0.000 0.000 0.000
6 0.000 0.000 0.000 0.000 0.000
5 0.000 0.000 0.000 0.000 0.000
4 3.0 3.0 4.50 9.000 6.000 54.000 10.500 94.500
3 4.5 3.0 3.00 13.500 5.250 70.875 7.500 101.250
2 6.0 3.0 1.50 18.000 4.500 81.000 4.500 81.000
1 7.5 3.0 0.00 22.500 3.750 84.375 1.500 33.750
h= 12.0 63.000 4.607 290.250 4.929 310.500

1 COULOMB'S THEORY

BACK

Active earth pressure Ka = Sin(+)


coefficient Sin Sin(-) 1+ Sin(+) Sin(-)
Sin(-) Sin(+)

0.687
0.989 0.959 1+ 0.771 0.166
0.959 0.910

0.687
1.814

0.379

Active soil thrust Ps = 0.5Kas H

= 3372.263 lb/ft

Active surcharge thrust Pq = Sin KaqH


Sin(+)

= 0.995 678.168
0.910

= 740.835 lb/ft

Horizontal active soil thrust Phs = PsCos(- )

= 3235.059 lb/ft

Horizontal active surcharge Phq = PqCos(- )


thrust
= 710.693 lb/ft

Vertical active soil thrust Pvs = PsSin(- )

= 952.130 lb/ft

Vertical active surcharge Pvq = PqSin(- )


thrust
= 209.168 lb/ft

FRONT

Inclination angle to vertical p = 0.000


Front face angle to horizontal p = 90-p
= 90.000
Backfill slope p = 0.000
Angle of wall friction p = 0.000

Passive earth pressure Kp = Sin(-)


coefficient Sin Sin(+) 1- Sin(+) Sin(+)
Sin(+) Sin(+)

0.780
1.000 1.000 1- 0.469 0.469
1.000 1.000

0.780
0.281

2.770

Passive soil thrust Pp = 0.5Kps d

= 1558.027 lb/ft

2 Check Overturning:

Vertical distance to Phs Yhs = H/3-BSin

= 3.194 ft

Vertical distance to Phq Yhq = H/2-BSin

= 5.183 ft

Overturning moment Mo = YhsPhs + YhqPhq

= 14016.823 ft-lb / ft

Weight of Gabion Wg = A g

= 6085.800 lb / ft

Horizontal distance to Wg Xg = Ysin + XCos

= 5.097 ft

Horizontal distance to Pvs Xvs = B/Cos + (H/3-BSin)Tan

7.877

Horizontal distance to Pvq Xvq = B/Cos + (H/2-BSin)Tan

8.086

Vertical distance to Pp YPp = d/3

= 1.000

Resisting moment Mr = Wg Xg + Pvs Xvs + Pvq Xvq + PpYPp


= 41769.145 ft-lb / ft

Overturning factor of safety SFo = Mr


Mo

2.980 2.000 O.K

3 Check Sliding

Total Normal forces W = WgCos + PsSin + PqSin - PpSin

= 7456.983 lb/ft

Frictional force Ff = W Tan

= 7456.983 0.532

= 3964.948

Total Resisting Forces Fr = Ff + CosPp

= 5514.440

Total Driving Forces at base Fd = PsCos + PqCos - WgSin

3166.609

Siding factor of safety SFs = Fr


Fd

1.741 1.500 O.K

4 Check the Eccentricity of Resultant Force


(Resultant is in middle one third)

Eccentricity e = 0.5 B - ( Mr - Mo)


W

= 3.750 - 3.722

= -B/6 e +B/6

-1.250 0.028 1.250


O.K O.K

5 Check Bearing

Applied bearing pressure P = W (1 6e/B)


B

= 994.264 (1 0.023 )

Left = 1016.810 psf 2000.000 O.K


Right = 971.719 psf 2000.000 O.K

Additional calculations may have to be performed including and not limiting to global stability analysis (by
(Geotechnical Engineer), seismic forces (by Seismic Engineer) and hydraulic forces (by Hydraulic Engineer).
Please check local, State and Federal requirements. The calculator assumes drained uniformed retained and foundation
soil properties. The calculations should be reviewed, checked and certified by a Professional Engineer. To the best of our
knowledge, the calculator and information was prepared accurately. Terra Aqua is not responsible for the reliability and
validity of the geotechnical parameters assumed in the calculations. The calculator is intended to provided design
design assistance to the engineer for the purpose of designing with Terra Aqua products.

Das könnte Ihnen auch gefallen