Preface

This manual deals only with the specifications, auxiliary equipment and data on installation of
the steam turbine, while the details such as the description of the construction of the steam turbine
proper, governing and safety system, oil system, auxiliary system and installation are stated in the
Volume 2 of Installation and Operation Manual., and the running of the steam turbine and the
operation of the electric governor in the Volume 3 of Installation and Operation Manual.

1. Scope of Application

Featuring a function of cogeneration, this steam turbine is applicable to the electric utility as
well as the self-sustained power stations of such industries as chemistry, petroleum, metallurgy,
fertilizer, sugar refinery, paper mill and waste disposal, etc.
The steam turbine is operation according with electric load.

0
2. Specifications

2-1. Main data on installation

Code K0990

Model N50-8.83(Air cooling)

Rated power KW 50000

Economic power KW 50000

Max. power KW 55000


Rated speed
r/min 3000
Rotation hand Ckw, seeing in the direction of
steam flow
Rated inlet press. and variation range 0.49
8.83 (abs)
MPa -0.49
Rated inlet temp. and variation range 5
535
-10
Rated
t/h 193.5
Inlet flow Max.
t/h 215
Condensate
t/h

I Non-control extraction press. MPa

Non-control extraction temp.

Non-control extraction flow t/h

Normal
34
Cooling water temp.
Max.

Rated exhaust pressure
MPa 0.0147(abs)
Number of feed-water regenerative stage
2JG+1CY+2JD
Feed-water temp.
~230
Rated working
condition kg/kw.h 3.87
Steam rate
Straight condensate
kg/kw.h
condition

1
Rated working
condition kj/kw.h 9613
Heat rate
Straight condensate
kj/kw.h
condition
Critical speed
r/min 1654/6371
Vibration amplitude of bearing housing at
rated speed(double-amplitude) mm 0.030
Vibration amplitude of bearing housing at
critical speed(double-amplitude) mm 0.15
Rotational inertia
kg-m2 2750
Weight of the steam turbine proper
t ~125
Max. lift for installation
t ~40
Max. lift for overhaul
t ~40
Weight of rotor
t ~15.523
Dimensions of steam turbine(above the 7.94.442.98
operating floor) m
LWH
Central elevation of steam turbine(from the
operating floor) m 0.8
Max. temp. of casing when turning gear stops
150
Max. temp. of rotor when turning gear stops
150
Min. height for suspending
m 6.5
Speed of turning gear
r/min ~9

2
2-2. Governing, safety and lubrication system

Speed variation
r/min 15
Speed regulation
% 3~6
Insensitivity of speed governing
% 0.25
Extraction press. regulation
I %
Insensitivity of extraction press.
regulation %
Extraction press. regulation
II %
Insensitivity of extraction press.
regulation %
Speed governing range of governor
synchronizer in no-load operation %
Speed governing range
r/min 0~3180Adjustable
Press. increment of main oil pump
MPa 1.9
Difference between the I pulse oil press and
the inlet oil press of main oil pump MPa 0.9
Difference between the II pulse oil press and
the inlet oil press of main oil pump MPa
Difference between the III pulse oil press and
the inlet oil press of main oil pump MPa
Electronic governing over-speed protection
r/min 3270
Speed of emergency governor
r/min 3300~3360
Over-speed protection of instrument
r/min 3390
Relative displacement of rotor which cause
the axial displacement limit device trip off mm 1.5
Limit of HP servomotor
mm 145
Limit of MP servomotor
mm
Limit of LP servomotor
mm
Lubricating oil pressure
MPa 0.08~0.12
Jacking oil press.
MPa ~12

3
Charging pressure of accumulator
MPa
Designation of turbine oil
L-TSA46

2-3. Setting

See in the black press. protection


Higher alarm value of exhaust press. MPa curve
Higher alarm value of exhaust temp.
120
Actuating press. of extraction safety
I valve MPa abs
Lower alarm value of extraction
press. MPa abs
Actuating press. of extraction safety
II valve MPa abs
Lower alarm valve of extraction
press. MPa abs
Outlet press. of main oil pump when the
motor-driven HP oil pump auto-start MPa 1.7 g

Alarm
MPa 0.055 g
AC Motor-driven oil pump
Low lube oil MPa 0.04 g
switches in
press.
DC Motor-driven oil pump
protection MPa 0.03 g
switches in

Shut-down MPa 0.02 (two of third) g


Motor-driven turning
gear mustnt go into MPa 0.015 g
service
High Alarm Scavenge oil
temp. 65
bearing
Temp. of
temp. bearing liner 85
protection Shut-down Scavenge oil
temp. 70

4
Temp. of
bearing liner 100

3. Main auxiliary equipment

Quantity Set 1
Main oil
pump Pressure increment MPa 1.9

Capacity 1/min 2000

Model 100AY1202

Quantity Set 1

Motor-driven Pressure raising Mpa(m) (240)


3

HPoil pump Flow m /h 100

Motor Power KW 132

Voltage V 415 AC

Model KCB-633

Quantity Set 1

AC auxiliary Pressure MPa(m) 0.28


3
oil pump
Flow m /h 38

Motor Power KW 11

Voltage V 415AC

Model KCB-633

Quantity Set 1

DC auxiliary Pressure (Raising) MPa(m) 0.28


3
oil pump
Flow m /h 38

Motor Power KW 10

Voltage V 110 DC
Jacking oil V20F-1S13S-1C11K-22
Model
pump
Quantity 2

5
Pressure bar 172.5

Exhaust flow ml/r 42.5

Motor Power KW 15

Voltage V 415AC
1
Quantity Set
Oil
ejectorI Outlet press. MPa 0.25

Outlet flow l/min 1200

Oil Quantity Set 1


ejectorII Outlet press. MPa 0.15

Outlet flow l/min 1800

Model TL650KBILx83 (Plate type)

Oil cooler Quantity Set 2


2

Cooling surface area m 54

Cooling oil flow l/min ~1200

Cooling water flow t/h ~150

Cooling water temp. 34

Water resistance Mpa 0.03

Tube material

Tube spec Mm
3

Volume m 12
Oil tank
Vacuum above oil level MPa 0.001

Model TD-375A

Gas Quantity Set 2


exhauster
Motor Power KW 0.375

Voltage V 415AC

Model LQ-40

Quantity Set 1
2
Shaft gland
Heating area m 40
cooler
Press. in water sidemax MPa 1.5

6
Water resistance MPa <0.019

Cooling water flow t/h 125-165

Exhaust fan Power KW 2.2

(2 set ) Voltage V 415AC

Condenser Model

Type

Cooling surface area

Steam press.

Steam flow

Cooling water flow

Cooling water temp.

Water resistance

Cooling water press.max.

Tube material

Tube spec

Net weight without water

Model

Type

HP heater Quantity
2

Heating area m

Press. in steam sidemax MPa

Press. in water sidemax MPa

Tube material

Tube spec mm

Model JD-125 (1#)

Type Vertical, U type tube

Quantity 1
LP heater
Heating area m2 125

7
Press. in steam sidemax Mpa 0.6

Press. in water sidemax MPa 1.2

Tube material HSn70-1A

Tube spec mm 201

Model JD-125 (2#)

Type Vertical, U type tube

Quantity 1
LP heater
Heating area m2 125

Press. in steam sidemax Mpa 0.3

Press. in water sidemax MPa 1.2

Tube material HSn70-1A

Tube spec mm 201

Steam Model

ejector Quantity

Working water raising MPa(m)


3

Working water flow m /h

Dry air extraction flow kg/h

Model Y132M2-6

Quantity 1
Turning
Power KW 5.5
gear
Voltage V 415AC

Mounting way B5

Speed of rotor rpm ~9

8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
9. Hot tightening values for the bolts of casing flange

Bolt size Out dia of Flange Rotation Rotation


nut thick. angle angle
Dmm Hmm Lmm

M1004380 145 275 52.48 66.40

M764360 110 275 52.48 50.39

M564240 85 175 27.66 20.52

10. Lift table for steam governing valve

NO Valve dia. Lift range h0.1 mm


Dmm
1 80Pear 3.5
2 80Pear 18.84
3 80Ball 34.15
4 80Ball 45.52
5 80Ball 54.68

23
5. Parameters at gauging points

Alarm value
Normal Interlock
Gauging point Unit Upper Lower remarks
value value
limit limit
Press. before MSV
MPa(a) 8.83 9.32 8.34
Press. behind control stage
MPa(a) ~6.112 Rated condition
Primary industrial extraction
press. MPa(a)
Non-controlled extraction
press. MPa(a)
Press. in exhaust chamber
MPa(a) 0.0147 Rated condition
Press variation range in surge
tank MPa(a) 0.103~0.13
Inlet press. of 1# LP heater
MPa(a) 0.255 Rated condition
Inlet press. of 2# LP heater
MPa(a) 0.099 Rated condition
Inlet press. of 3# LP heater
MPa(a)
Inlet press. of 1# HP heater
MPa(a) 2.901 Rated condition
Inlet press. of 2# HP heater
MPa(a) 1.614 Rated condition
Press. in the steam side of shaft
gland cooler MPa(a) 0.095~0.097
Press. of blower for shaft gland
cooler MPa(a) 0.095~0.097
Working steam pressure for
gland heater MPa(a)
Press. in the steam side of
gland heater MPa(a)
Press. in mixing chamber of water-
jet air ejector MPa(a)
Inlet press. of water-jet air ejector
MPa(a)
Working steam pressure for
starting ejector MPa(a)
Press. in mixing chamber of
starting ejector MPa(a)

24
Working steam pressure for two-
stage steam ejector MPa(a
Press in the mixing chamber of two-
stage steam ejector MPa(a)
Lube oil pressure Two of third
MPa(g) 0.08~0.12 0.055 0.02
Low lube AC lube oil pump
oil press switches in MPa(g) 0.04
protection
DC lube oil pump
switches in MPa(g) 0.03
Turning gear
mustnt switch-in MPa(g) 0.015
Alarm value
Normal Interlock
Gauging point Unit Upper Lower remarks
value value
limit limit
Inlet press. of main oil pump MPa(g) 0.1
Outlet press. of main oil pump MPa(g) 2.0
Outlet Auxiliary oil pump
MPa(g) Manual
pressure shut-down
protection Auxiliary oil pump
for main MPa(g) 1.7
auto-start
oil pump
Control oil pressure for MSV MPa(g) >1.2
Safety oil pressure Electric shut-
MPa(g) 2.0 0.8
down
I pulse oil press. MPa(g) ~1.0
II pulse oil press. MPa(g)
III pulse oil press. MPa(g)
Working oil press. for EH MPa(g) 2.0
system
Control oil press. for EH MPa(g)
system
Press. before the oil strainer for MPa(g) 0.1
jacking oil pump
Press. behind the oil strainer MPa(g) 0.1
for jacking oil pump
Jacking oil press. for front MPa(g) Measured
bearing of steam turbine
Jacking oil press. for rear MPa(g) Measured
bearing of steam turbine
Jacking oil press. for front MPa(g) Measured
bearing of generator
Jacking oil press. for rear MPa(g) Measured
bearing of generator
Outlet oil press. for turning MPa(g) ~11.5
jacking pump
Outlet oil press. Switch in MPa(g) >11.0
interlock for turning
jacking pump of gear
turning gear
Scavenge oil temp. of turbine <60 65 70
front bearing

25
Scavenge oil temp. of turbine <60 65 70
rear bearing
Scavenge oil temp. of <60 65 70
thrust bearing
Scavenge oil temp. of <60 65 70
generator front bearing
Scavenge oil temp. of <60 65 70
generator rear bearing
Liner temp of turbine front <80 85 100
bearing
Liner temp of turbine rear <80 85 100
bearing

Gauging points Unit Normal Alarm value Interlock remarks


value value
Upper Lower
limit limit
Thrust pad temp. <80 85 100
Liner temp of generator front <80 85 100
bearing
Liner temp of generator rear <80 85 100
bearing
Inlet oil temp. of oil cooler 45~55
Outlet oil temp. of oil cooler 40~45 50 25
Steam temp. before MSV 535 540 525
Temp. after control stage of ~492 Rated condition
turbine
Primary industrial extraction
temp.
Non-controlled extraction
temp.
Temp. of exhaust chamber ~54 Rated condition
Inlet temp. of exhaust device 54
Condensate temp. of exhaust 54
device
Temp. of air extraction
chamber for condenser
Temp. of surge tank <300
Inlet steam temp. of ~136 Rated condition
1# LP heater
Inlet steam temp. of ~99 Rated condition
2# LP heater
Inlet steam temp. of
3# LP heater
Inlet steam temp. of ~396 Rated condition
1# HP heater
Inlet steam temp. of ~324 Rated condition
2# HP heater
Inlet water temp. of ~99 Rated condition
1# LP heater
Outlet water temp. of ~128 Rated condition
1# LP heater

26
Inlet water temp. of ~54 Rated condition
2# LP heater
Outlet water temp. of ~99 Rated condition
2# LP heater
Inlet water temp. of
3# LP heater
Outlet water temp. of
3# LP heater
Inlet water temp. of ~202 Rated condition
1# HP heater
Outlet water temp. of ~230 Rated condition
1# HP heater
Gauging points Unit Normal Alarm value Interlock Remarks
value value
Upper Lower
limit limit
Inlet water temp. of ~158 Rated condition
2# HP heater
Outlet water temp. of ~202 Rated condition
2# HP heater
Inlet water temp. of 34
Oil cooler
Outlet water temp. of ~36
Oil cooler
Inlet water temp. of water-jet
air ejector
Temp. difference of upper and 50 55
lower half of casing
Level in shaft gland cooler mm 50 70 From central line
under level meter
1#LP water level mm 400 650 200 From central line
under level meter
2#LP water level mm 400 650 200 From central line
under level meter
3#LP water level mm
1#HP water level mm
2#HP water level mm
Water level in hot well mm 600 1000 200 From central line
under level meter
Oil level in oil tank mm 300 150 450 From top plate of
oil tank
Axial displacement of rotor for mm 1.0 1.0 1.5
turbine
Differential expansion mm ~1.5 +3/-2 +4/-3
Vibration of turbine front mm 0.03 0.05 0.07
bearing housing
Vibration of turbine rear mm 0.03 0.05 0.07
bearing housing
Vibration of generator front mm 0.03 0.05 0.07
bearing
Vibration of generator rear mm 0.03 0.05 0.07
bearing
Vibration of turbine front mm 0.080 0.16 0.25
bearing housing relatively

27
Vibration of turbine rear mm 0.080 0.16 0.25
bearing housing relatively
Vibration of generator front mm 0.080 0.16 0.25
bearing relatively
Vibration of generator rear mm 0.080 0.16 0.25
bearing relatively
mm ~13.2 decided
Absolute expansion
at site
Speed r/min 3000 3210 3270(DEH)
3390(TSI)

Gauging points Unit Normal Alarm value Interlock Remarks


value value
Upper Lower
limit limit
Start turning gear r/min 1
Shut turning gear r/min 15
Interlock
of turbine Start jacking oil
speed r/min 200
pump
Shut jacking oil r/min 210
pump

28
29