Sie sind auf Seite 1von 2

8 7 6 5 4 3 2 1

RACK FRONT

3.0 X 8.0 PLATES 16.60 7.40


FOR CABLE ENTRY
F
F

30.50
3.0 X 8.0 PLATES
FOR CABLE ENTRY 10.75
28.32
21.50

.56 TYP

E BOTTOM VENTILATION E
NOT SHOWN IN BOTTOM VIEW 29.90

BOTTOM VIEW

31.40

D D

C
C

84.0

B
B

FRONT VIEW REAR VIEW


RACK NOTES:

1. EMPTY RACK WEIGHT: 530 LBS.


2. FULLY WELDED FRAME. MANUFACTURED FROM HEAVY GAUGE STEEL.
A
3. POWDER COATED WITH A CORROSION RESISTANT POWDER USING A
UNLESS OTHERWISE SPECIFIED: 3233 W. Kingsley Rd.
Ste. 200 A
ELECTRONIC SYSTEM SUPPORT
ESS
FIVE STAGE EMERSION PRETREATMENT PROCESS.
DIMENSIONS ARE IN INCHES Garland, Texas 75041
TOLERANCES: 888-475-9292 www.ess.to PH. 972-272-2468

4. BATTERIES CAN BE ACCESSED FROM FRONT, REAR, AND BOTH SIDES. ANGULAR: MACH .5 BEND 1 FAX 972-276-9844
TWO PLACE DECIMAL .02 NAME DATE TITLE:
5. CUSTOM DESIGNED PALLETS FOR SHIPPING ANYWHERE, LOCALLY AND GLOBALLY. THREE PLACE DECIMAL .01
DRAWN RNA 3-6-13 CABINET, RACK, 16V FT,
5 TIER/TOP BRKR
6. BATTERY RACK CAN BE MOVED WITH A NORMAL PALLET JACK FROM FRONT AND REAR.
PROJECTION:
PROPRIETARY AND CONFIDENTIAL CHECKED

7. STANDARD AND CUSTOM SPILL CONTAINMENT OPTIONS ARE AVAILABLE.


THE INFORMATION CONTAINED IN THIS MATERIAL
DRAWING IS THE SOLE PROPERTY OF
ENG APPR. SIZE DWG. NO. REV
SEE NOTE 1
ELECTRONIC SYSTEMS SUPPORT. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
ELECTRONIC SYSTMES SUPPORT IS USED ON
FINISH
SEE NOTE 2
MFG APPR.

Q.A.
D EFR5B-SPEC A
PROHIBITED. DO NOT SCALE DRAWING SCALE: 1:16 WEIGHT: SHEET 1 OF 2
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1

BREAKER DETAIL
BATTERYRACKPARTNUMBERGUIDE
RACKPARTNUMBER DESCRIPTION
EFR5B A A
OUTPUT TO UPS
TO BREAKER OR BASEPARTNUMBER F
F FUSE PANEL + -

- +
RACKHEIGHT

RACKCOLOR
FROM BATTERY POS.

FROM BATTERY NEG.


BATTERYCONFIGURATIONTABLE
- + - + - + - + - + - +
MAXIMUMNUMBEROF
GND BATTERYMANUFACTURER
BATTERIESPERRACK
E
BREAKER ENERSYS
E

BRACKET
BATTERYMODEL
16HX550FFR 30
NUMBER

- + - + - + - + - + - + FROM BREAKER OPTIONS HEIGHTLEGEND COLORLEGEND


HEIGHT(INCHES) AVAILABILITY **A=BLACK
TO **A=84.00 INSTOCK B=BEIGE
24/48/120 VDC B=82.00 N/A C=LIEBERTGRAY
SOUCE

BLUE/YELLOW
BLUE/YELLOW
C=80.00 N/A D=MITSUBISHIBEIGE
D=79.0 N/A E=MGEWHITE

YELLOW
YELLOW
D E=78.7 N/A F=TOSHIBABLACK

BLACK
BLACK
D

BLUE
BLUE
F=78.4 N/A G=GEWHITE
- + - + - + - + - + - + G=78.0 N/A H=LIEBERTBLACK
H=77.3 N/A J=EATONBLACK
J=76.8 N/A K=TBD
K=75.3 N/A
L=75.0 N/A **BLACKISESSSTANDARDCOLOR
M=74.8 N/A ANDWILLBEINSTOCK**
N=73.5 N/A LETTERSSTATING"TBD"AREOPEN
FORCUSTOMCOLORSNOTLISTED.
P=72.0 N/A
- + - + - + - + - + - + Q=71.7 N/A
PLEASECONSULTWITHSALES
STAFFFORFURTHERINFO.
R=70.9 N/A
S=TBD N/A

NO
COMMON
NO
FROM UPS

NC

NC
COMMON
TO UPS
C
C T=TBD N/A

**84.0ISTHESTANDARDHEIGHTFORTHEEFR5B
RACK.SHORTERHEIGHTSARENOTAVAILABLE**
PLEASECONSULTWITHSALESSTAFFFORFURTHER
INFO.
- + - + - + - + - + - +
TO UPS
AUXILLARY CONTACTS LISTED APPLICABLE WHEN
BREAKER IS IN THE CLOSED (ON) POSITION

B
B

PART NUMBER GUIDE:


FUSE OPTION
1. REFERENCE THE BATTERY PART NUMBER GUIDE TABLE WHEN ORDERING A RACK.
2. THE BASE NUMBER WILL ALWAYS BE THE SAME. HOWEVER, 2 ALPHA DIGITS WILL
FUSE PANEL FOLLOW THE BASE NUMBER INDICATING THE HEIGHT AND COLOR OF THE RACK.
3. REFERENCE THE "HEIGHT LEGEND" TABLE AND THE "COLOR LEGEND" TABLE IN ORDER
TO DETERMINE THE 2 ALPHA DIGITS NEEDED TO COMPLETE YOUR ORDER.
4. EXAMPLE: EFR5BAA - THIS REPRESENTS A STANDARD EFR5B RACK, 84.0 INCH HEIGHT
ELECTRICAL NOTES: WITH A POWDER COAT FINISH OF STANDARD BLACK.
FROM BATTERY POS. FUSE TERMINAL + OUTPUT 5. THE EFR5B RACK IS NOT AVAILABLE IN OTHER HEIGHTS OTHER THAT 84.0 INCHES.
1. ALL CABLES ARE UL LISTED.
2. ALL BREAKERS ARE UL RECOGNIZED. FROM BATTERY NEG. BLOCK - TO UPS
A UNLESS OTHERWISE SPECIFIED: 3233 W. Kingsley Rd.
A
3. ALL FUSES ARE UL RECOGNIZED, TYPE A50P, A70P OR EQUIVALENT.
Ste. 200
ELECTRONIC SYSTEM SUPPORT
DIMENSIONS ARE IN INCHES
TOLERANCES:
ESS 888-475-9292 www.ess.to
Garland, Texas 75041

ALWAYS REPLACE WITH SAME TYPE OR ITS EQUIVALENT.


PH. 972-272-2468
FAX 972-276-9844
GND. ANGULAR: MACH .5 BEND 1

4. TERMINAL BLOCKS ARE UL RECOGNIZED, 600V RATED.


TWO PLACE DECIMAL .02
THREE PLACE DECIMAL .01
NAME DATE TITLE:
RNA 3-6-13 CABINET, RACK, 16V FT,
5. RACKS ARE SHIPPED WITH THE BREAKER IN THE TRIPPED POSITION.
DRAWN

PROPRIETARY AND CONFIDENTIAL


PROJECTION:
CHECKED
5 TIER/TOP BRKR
6. RACK GROUND CONNECTION IS A 5/16-18 THREADED STUD. THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
MATERIAL
SEE NOTE 1
ENG APPR. SIZE DWG. NO. REV

7. CABLES BETWEEN BATTERY RACK TO UNINTERRUPTIBLE POWER SUPPLY ARE OPTIONAL.


ELECTRONIC SYSTEMS SUPPORT. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
ELECTRONIC SYSTMES SUPPORT IS USED ON
FINISH
SEE NOTE 2
MFG APPR.

Q.A.
D EFR5B-SPEC A
PROHIBITED. DO NOT SCALE DRAWING SCALE: 1:16 WEIGHT: SHEET 2 OF 2
8 7 6 5 4 3 2 1