Beruflich Dokumente
Kultur Dokumente
Cabinet Combination
www.huawei.com
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page1
Contents
1. Basic concept of BTS Cabinet Combination
3. Data configuration
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page2
Contents
1. Cables between BTS cabinets
1.1 Basic Concept of BTS3900 Cabinet Combination
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page3
Basic Configuration Principles
The BTS3900 developed by Huawei is an indoor macro
BTS. The BTS3900 mainly consists of the BBU and DRFUs
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page4
Basic Configuration Principles
Minimum cost
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page5
RF Configuration Principles
A maximum of three levels of DRFUs can be connected to
one BBU
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page6
Configuration Principles of the BBU
One BBU supports six CPRI ports. The star topology is recommended
between DRFUs
Minimum number of trunk cables. You can determine the number of trunk
cables as required, and take the existing configuration for saving
transmission resources into account in networking
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page7
Structure of the BTS3900 Cabinet
Fan box
-48V Cabinet
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page8
Structure of the BTS3900 Cabinet
Fan box
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page9
Logical Structure and Signal Flow
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page10
Boards and Modules in BBU
BSBC: The universal BBU subrack backplane type C
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page11
GTMU
Controls, maintains, and operates the BTS
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page12
UPEU
The universal power and environment interface unit (UPEU) supports the -
48V /-24V DC power input, supplies power to the boards, modules, and fan
in the BBU, and provides access to multiple environment monitoring
signals
Port Type Description
Transmitting two RS485
MON0 RJ45
environment monitoring signals
Transmitting two RS485
MON1 RJ45
environment monitoring signals
EXT- Transmitting four dry contact
RJ45
ALM0 alarms
EXT- Transmitting four dry contact
RJ45
ALM1 alarms
PWR 3V3 +24 V/-48 V DC power input
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page13
UEIU
UEIU is the environment interface board of BBUit can support
multi-route monitoring signal input
UEIU is optional and is only used when more ports are needed
Connector
Label Description
Type
MON0 RJ45 One RS485 signal
MON1 RJ45 One RS485 signal
EXT- Four dry contact
RJ45
ALM0 signals
EXT- Four dry contact
RJ45
ALM1 signals
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page14
Contents
1. Basic concept of BTS combination
3. Data configuration
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page15
Cabinet Combination
When the DRFU is used for configurations larger than S444 and no
greater than S888, two cabinets in combined or stack mode are required.
In the case that the area and height of the equipment room meet the
requirements of both the combined and stack modes, the stack mode is
recommended for easy capacity expansion
When the configuration is larger than S888 and no greater than S121212,
three cabinets in combined mode are required
For internal monitoring of two or three +24 V DC/220 V AC cabinets, one
UEIU is required. Note that only the 48 V DC cabinet supports the stack
installation
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page16
Contents
2. Cables between BTS cabinets
2.1 Combined Mode
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page17
Two Cabinets in Combined Mode
Installation Procedures
After installing the two cabinets side by side, remove the connecting plates on top of
the two cabinets. Then, connect the two cabinets by using the connecting plates at
the back of the cabinets and then install the equipotent cable
The cables inside the cabinet are installed before delivery
Connect the two monitoring cables between two cabinets.
For example, two monitoring cables are required for combined 48 V DC cabinets: One is
connected to the COM IN port on the FMUB in the extension cabinet and the COM OUT port
on the FMUB in the basic cabinet. Another is connected to the EXT-ALM0 port on the BBU
and the MON port on the DCDU-01 in the extension cabinet.
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page18
Installing the power cable between
cabinet
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page19
Monitoring System
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page20
Installing monitoring cable
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page21
Installing monitoring cable
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page22
Installing the RF Jumpers
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page23
Installing PGND cable
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page24
Installation Note
Besides installing the equipotential cable between the two cabinets, install a
grounding cable for each cabinet
Install two bases for the cabinets in combined mode
The power cable of each cabinet in combined mode is independent. The
installation of the input power cable is the same as that for a single cabinet.
The power cables inside the cabinet are installed before delivery
The routing and connection of the E1 cable and RF jumper are the same as
those for a single cabinet
The cabinet installed with the BBU acts as the basic cabinet, and the other as
the extension cabinet
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page25
Combined Mode
Cable connections of the monitoring cables in the 48 V DC
cabinet
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page26
Combined Mode
Monitoring principles of the 48 V DC cabinet configured
with optional devices
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page27
Combined Mode
Cable connections of the monitoring cables in the +24 V DC
cabinet
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page28
Combined Mode
Monitoring principles of the 48 V DC cabinet configured
with optional devices
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page29
Combined Mode
Cable connections of the monitoring cables in the 220 V AC
cabinet
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page30
Combined Mode
Monitoring principles of the 220V AC cabinet configured
with optional devices
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page31
Contents
2. Cables between BTS cabinets
2.1 Combined Mode
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page32
Two Cabinets in Stack Mode
Install the basic cabinet on the base
Remove the filler and connecting plate from the top of the cabinet.
Then, install the installation block on top of the cabinet
Install the extension cabinet on top of the basic cabinet, and then
secure the two cabinets
Install the equipotential cables and monitoring cables of the two
cabinets
Install the RF jumpers and E1 cables of the two cabinets
Feed power to the cabinets
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page33
Cabinets in stack mode
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page34
CPRI cable connections
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page35
Connections of the RF jumpers
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page36
Contents
1. Principle of BTS combination
3. Data configuration
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page37
Typical configuration S8/8/8
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page38
Add BTS3900 Site
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page39
Add DRFU boards
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page40
Binding logical TRX
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page41
Add FMU boards
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page42
Set Attributes
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page43
Summary
Principle to combine BTS
Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page44
Thank you
www.huawei.com