Objectives
 Upon completion of this course, you will be able to:
 Describe the principle to combine BTS cabinets

 Outline the hardware needed for BTS cabinet combination

 Configure data for BTS combination

 Monitor design of BTS combination

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page1
Contents
1. Basic concept of BTS Cabinet Combination

2. Cables between BTS cabinets

3. Data configuration

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page2
Contents
1. Cables between BTS cabinets
1.1 Basic Concept of BTS3900 Cabinet Combination

1.2 Hardware of BTS3900 Cabinet Combination

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page3
Basic Configuration Principles
 The BTS3900 developed by Huawei is an indoor macro
BTS. The BTS3900 mainly consists of the BBU and DRFUs

 A single BTS3900 cabinet provides up to 12 carriers with


the maximum cell configuration of S4/4/4, and supports the
dual-band application

 Multiple cabinets support up to 72 carriers in the maximum


cell configuration of S24/24/24

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page4
Basic Configuration Principles
 Minimum cost

 Smooth upgrade of configuration

 Minimum number of DRFUs

 Minimum number of BBUs

 Minimum number of antennas

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page5
RF Configuration Principles
 A maximum of three levels of DRFUs can be connected to
one BBU

 Mode of configuring two TRXs in one cell


 A single DRFU does not support the S1/1 application; however,
three DRFUs support the S3/3 application

 When the DRFU works in transmit PBT, transmit diversity, or 4-


way receive diversity mode, a DRFU provides only one TRX.
Therefore, the actual configuration does not involve the mode
of configuring two TRXs in one cell

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page6
Configuration Principles of the BBU
 One BBU supports six CPRI ports. The star topology is recommended
between DRFUs

 Minimum number of trunk cables. You can determine the number of trunk
cables as required, and take the existing configuration for saving
transmission resources into account in networking

 Minimum number of UPEUs. The configuration of a single UPEU is


recommended. The redundancy backup mode can be configured if
required

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page7
Structure of the BTS3900 Cabinet

Double radio filter unit

Fan box

GSM antenna and TMA control module


Baseband unit
Direct current distribution unit

-48V Cabinet

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page8
Structure of the BTS3900 Cabinet

Double radio filter unit

Fan box

GSM antenna and TMA control module


Baseband unit
Direct current distribution unit
Power supply unit

+24V or 220VAC Cabinet

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page9
Logical Structure and Signal Flow

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page10
Boards and Modules in BBU
 BSBC: The universal BBU subrack backplane type C

 GTMU: The GSM Transmission, Timing and Management Unit

 UBFA: The universal BBU fan unit type A

 UPEU: The universal power and environment interface unit

 UELP: The universal E1/T1 lightning protection unit

 UEIU: The universal environment interface unit

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page11
GTMU
 Controls, maintains, and operates the BTS

 Monitors the fan module and the power supply module

 Provides the Ethernet port for terminal maintenance

 Supports four E1 inputs

 Provides the CPRI ports for communication with the DRFU

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page12
UPEU
 The universal power and environment interface unit (UPEU) supports the -
48V /-24V DC power input, supplies power to the boards, modules, and fan
in the BBU, and provides access to multiple environment monitoring
signals
Port Type Description
Transmitting two RS485
MON0 RJ45
environment monitoring signals
Transmitting two RS485
MON1 RJ45
environment monitoring signals
EXT- Transmitting four dry contact
RJ45
ALM0 alarms
EXT- Transmitting four dry contact
RJ45
ALM1 alarms
PWR 3V3 +24 V/-48 V DC power input

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page13
UEIU
 UEIU is the environment interface board of BBUit can support
multi-route monitoring signal input
 UEIU is optional and is only used when more ports are needed

Connector
Label Description
Type
MON0 RJ45 One RS485 signal
MON1 RJ45 One RS485 signal
EXT- Four dry contact
RJ45
ALM0 signals
EXT- Four dry contact
RJ45
ALM1 signals

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page14
Contents
1. Basic concept of BTS combination

2. Cables between BTS cabinets

3. Data configuration

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page15
Cabinet Combination
 When the DRFU is used for configurations larger than S444 and no
greater than S888, two cabinets in combined or stack mode are required.
In the case that the area and height of the equipment room meet the
requirements of both the combined and stack modes, the stack mode is
recommended for easy capacity expansion
 When the configuration is larger than S888 and no greater than S121212,
three cabinets in combined mode are required
 For internal monitoring of two or three +24 V DC/220 V AC cabinets, one
UEIU is required. Note that only the 48 V DC cabinet supports the stack
installation

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page16
Contents
2. Cables between BTS cabinets
2.1 Combined Mode

2.2 Stack Mode

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page17
Two Cabinets in Combined Mode
 Installation Procedures
 After installing the two cabinets side by side, remove the connecting plates on top of
the two cabinets. Then, connect the two cabinets by using the connecting plates at
the back of the cabinets and then install the equipotent cable
 The cables inside the cabinet are installed before delivery
 Connect the two monitoring cables between two cabinets.
 For example, two monitoring cables are required for combined 48 V DC cabinets: One is
connected to the COM IN port on the FMUB in the extension cabinet and the COM OUT port
on the FMUB in the basic cabinet. Another is connected to the EXT-ALM0 port on the BBU
and the MON port on the DCDU-01 in the extension cabinet.

 Install the RF jumpers and E1 cables


 Feed the power to the two cabinets using the same method as that for a single
cabinet

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page18
Installing the power cable between
cabinet

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page19
Monitoring System

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page20
Installing monitoring cable

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page21
Installing monitoring cable

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page22
Installing the RF Jumpers

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page23
Installing PGND cable

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page24
Installation Note
 Besides installing the equipotential cable between the two cabinets, install a
grounding cable for each cabinet
 Install two bases for the cabinets in combined mode
 The power cable of each cabinet in combined mode is independent. The
installation of the input power cable is the same as that for a single cabinet.
The power cables inside the cabinet are installed before delivery
 The routing and connection of the E1 cable and RF jumper are the same as
those for a single cabinet
 The cabinet installed with the BBU acts as the basic cabinet, and the other as
the extension cabinet

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page25
Combined Mode
 Cable connections of the monitoring cables in the 48 V DC
cabinet

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page26
Combined Mode
 Monitoring principles of the 48 V DC cabinet configured
with optional devices

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page27
Combined Mode
 Cable connections of the monitoring cables in the +24 V DC
cabinet

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page28
Combined Mode
 Monitoring principles of the 48 V DC cabinet configured
with optional devices

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page29
Combined Mode
 Cable connections of the monitoring cables in the 220 V AC
cabinet

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page30
Combined Mode
 Monitoring principles of the 220V AC cabinet configured
with optional devices

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page31
Contents
2. Cables between BTS cabinets
2.1 Combined Mode

2.2 Stack Mode

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page32
Two Cabinets in Stack Mode
 Install the basic cabinet on the base
 Remove the filler and connecting plate from the top of the cabinet.
Then, install the installation block on top of the cabinet
 Install the extension cabinet on top of the basic cabinet, and then
secure the two cabinets
 Install the equipotential cables and monitoring cables of the two
cabinets
 Install the RF jumpers and E1 cables of the two cabinets
 Feed power to the cabinets

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page33
Cabinets in stack mode

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page34
CPRI cable connections

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page35
Connections of the RF jumpers

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page36
Contents
1. Principle of BTS combination

2. Cables between BTS cabinets

3. Data configuration

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page37
Typical configuration S8/8/8

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page38
Add BTS3900 Site

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page39
Add DRFU boards

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page40
Binding logical TRX

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page41
Add FMU boards

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page42
Set Attributes

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page43
Summary
 Principle to combine BTS

 Cables between cabinets and groups

 Data configuration about cabinet combination

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved. Page44
Thank you
www.huawei.com

Das könnte Ihnen auch gefallen