Sie sind auf Seite 1von 2

NETWORK AND SERVICE ENABLEMENT

Wireless Test Kits | Essential Cell-Site Testing


Installation and Maintenance
of LTE/FTTA Cell Sites
1
7 2 JB 7 RRU
7
RRU
JB

6
RRU
RRU
9 1 1 JB 8
8 2 2 9
6
BBU Baseband unit
RRU Radio remote unit
JB Junction box

1
1 2
JB BBU JB
3 6 3
2 4
Backhaul
4 Backhaul

5 5
Rooftop Architecture Macrocell Site Architecture

1

Inspection and Cleaning
Visually inspect and certify the quality and cleanliness of the fiber connectors
5

CPRI/OBSAI and Ethernet
Verify CPRI/OBSAI links between the BBU-RRU. Emulate the CPRI/OBSAI protocol
located at both sides (patch cord and bulkhead) of a connection. to ensure no code violations, BER errors, delays, or framing issues. Verify SLAs
on Ethernet backhaul links. Ensure link quality, throughput, and QoS from L1
2

Visual Fault Locator (VFL)
Check continuity, identify channels, and verify with your co-worker at the
through L4. Perform RFC 2544/Y.1564sam, committed burst size (CBS), and
TrueSpeed RFC 6349 tests.
remote end that you are testing the correct fiber.
6 Radio Conformance
3

Optical Power Meter (OPM)
Measure optical power levels at the equipment or connection point or perform
Verify that RF signal integrity (power levels, RF leakage, and spurious) meets
standards.
link or channel insertion loss measurements (with an optical light source).
7 Cellular Signal Quality
4

OTDR
Construction Phase
Measure cell-site transmission over the air for proper signal modulation
performance to ensure quality of service.
Characterize cell tower and rooftop fiber link and network
component build quality (connector loss and reflectance,
link loss and reflectance)
8

Sweep (VSWR, DTF)
Measure coaxial reflections and distance to fault of coaxial lines.
Characterize backhaul fiber
Maintenance/Troubleshooting Phase 9

PIM Detection
Measure passive inter-modulation in coaxial lines with active transmitters.
Verify output and/or receive power level of the equipment (Rx/Tx)
Locate and identify causes of fiber or component issues or failure
Wireless Test Kits | Essential Cell-Site Testing

Fiber Acceptance Test Tier 1 Fiber Acceptance Test Tier 2 CPRI/OBSAI Validation Test RF and Fiber Analyzer and Test
Part numbers: FIT-COMM-B, FBP-COMM-T Part number: TB2-FTTA-QU-P Part numbers: MTS-5801/5812/5812P Part number: JD745AB04

123 1234 135 13 6 7 8 9

Complete jobs faster, correctly with Fully qualify your cell tower and Verify CPRI- or OBSAI-based Fully characterize cellular
pass/fail, and on timethe first time rooftop fronthaul transmission quality
Efficient, easy-to-use SmartClass Fiber All-in-one kit integrating a high Ensured connectivity to the RRU without Integrated high-performance cell-site
tools with integrated inspection, test, and performance OTDR climbing the tower. Verify error-free analyzer with RF characterization, sweep
best practices cut testing and certification (sharp resolution) with inspection and transmission with BERT and proper test, PIM-detection, and signal analysis of
time in half. essential fiber test tools for detailed CPRI and OBSAI alarm reporting. CDMA/EV-DO and LTE.
analysis of your link components.
Complete jobs faster with auto- Ensure that Ethernet backhaul Complete jobs faster with pass/fail
centering, an integrated patch cord Simplify and speed OTDR testing misconfiguration does not cause spectrum masks and Fiber Testing
microscope (PCM), and special with an OTDR application designed retransmissions on the wireless Perform all traditional RF cell-site tests,
duplex LC/SC inspection adapters specifically for cell tower/rooftop spectrum including Inspect Before You Connect
Getting fiber on the screen is now easy. testing - Perform RFC 2544 or Y.1564 tests (IBYC) tests and power measurements,
No need to change tips at the top of the - No complex setup required to validate Ethernet-layer KPIs: on sites with fiber links. The P5000i Fiber
towerswitch between a bulkhead and throughput, latency, packet loss, jitter, Microscope ensures all fiber connections
- Simple icon-based schematic displays are clean and power levels are verified,
the patch cord microscope with just one and committed burst size (CBS)
button click. Plug in the duplex LC and - Auto identification and analysis of while the MP-60/80 optical power meter
network elements - Ensure Layer 2 control-plane enables users to turn up cell sites and get
slide to inspect each connector. transparency with the automated
Immediately diagnose fiber them running faster. Users can certify
Easily generate certification reports J-Proof test fiber connectors and power for a lifetime
network infrastructure quality
Prove that your work quality meets - Guarantee high-quality customer and avoid the presence of any RF interfer-
Isolate issues with pass/fail measurement data throughput with RFC 6349 ence before commissioning.
industry standards and specifications. results. TrueSpeed
Flexibility for use anywhere Easy and systematic pass/fail sweep
Easily generate certification reports - Validate all the above KPIs for conformance
Use the portable, organized, hands-free Prove that your work quality meets multiple flows based on Y.1564sam
carrier up cell towers and on cell sites. Certify cable runs quickly and easily with
industry standards and specifications. specifications (SAMComplete) and
pass/fail indications according to custom
Eliminate subjective guesswork guarantee QoS and CoS specifications.
Flexibility for use anywhere
with pass/fail analysis - Validate the customer experience
Use the portable, organized, hands-free and TCP throughput using RFC 6349 Immediate diagnostic of
This unique, automated handheld tool carrier up cell towers and on cell sites. modulation performance
certifies fiber end-face condition and TrueSpeed-based tests
measures optical power with pass/ Eliminate subjective guesswork Automated workflows and report Obtain modulation profiles of CDMA/
fail results. Technicians use the same generation EV-DO and LTE signals to promptly
with pass/fail analysis
parameters across the entire network. identify problems and expedite
This unique, automated handheld tool Prove that your work quality meets industry resolution.
certifies fiber end-face condition and standards and operators specifications with
measures optical power with pass/ an automatic pass/fail test. Verify the system for passive
fail results. Technicians use the same intermodulation
parameters across the entire network. Ensure network timing
Perform in-service PIM detection tests to
synchronization
certify the installation of the entire system
- Ensure Layer 2 control-plane is not generating unwanted RF noise.
transparency with the automated
J-Proof test Automated testing and report
- Guarantee high-quality customer generation
data throughput with RFC 6349 Prove that your work quality meets
TrueSpeed industry standards and specifications
with an automated pass/fail test.
Ordering Information
Part Number Description
FIT-COMM-B Bottom tower: OLP-82P with OPM, P5000i, FiberChekPRO software, LC and SC duplex inspection tips/adapters, cleaning tools, utility carrier, carrying case
FBP-COMM-T Top tower: HD4iP with PCM, P5000i, FiberChekPRO software, LC and SC duplex inspection tips/adapters, cleaning tools, utility carrier, carrying case
TB2-FTTA-QU-P T-BERD/MTS-2000 with SM/MM OTDR module, OPM, SLM-FTTA app, VFL, P5000i, LC and SC inspection tips, utility carrier, cleaning tools, carrying case
JD745AB04 CellAdvisor JD745A with soft carrying case, GPS receiver and antenna, 2-port test, CW signal generator, interference and signal analysis for CDMA/EV-DO/LTE
MTS-5801/5812/5812P Portable, all-in-one Ethernet test instrument

North America Latin America Asia Pacific EMEA www.jdsu.com/nse


Tel: 1 855 ASK-JDSU Tel: +1 954 688 5660 Tel: +852 2892 0990 Tel: +49 7121 86 2222
1 855 275-5378 Fax: +1 954 345 4668 Fax: +852 2892 0770 Fax: +49 7172 86 1222

Product specifications and descriptions in this document subject to change without notice.
2013 JDS Uniphase Corporation 30175779 001 1113 WIRELESSKITS.PB.FOP.NSE.AE