Sie sind auf Seite 1von 5

Department: Electrical Engineering and Computer Science 6.

6. A 3-phase, 460V, 15hp, 60Hz, four pole, 1728 rpm induction on motor delivers full output

Course : EECS 3505 power to a load connected to its shaft. The motor runs at 1800 rpm at no load. The windage

Title: Electrical Systems for Mechanical Engineers and friction loss of the motor is 750W. Determine the:

Course Director: Hany E. Z. Farag a. Mechanical power developed


b. Air gap power
Assignment [5]
c. Rotor copper loss
7. A 60Hz four pole 208V three-phase induction motor has the following parameters
1. At what speed will a 12-pole 60-Hz induction motor operate if the slip is 0.06?
R1=0.3 X1=1
2. A three-phase induction motor runs at almost 1200 r/min at no load and 1140 r/min at full
load when supplied with power from a 60-Hz three-phase line. R2 X2

a. How many poles have the motor? Gc= 20*10-3 Bm=60*10-3


b. What is the percent slip at full load? Find the speed and stator current for a slip 2%. For a load slip of 5%, find the motor power
c. What is the corresponding frequency of the motor voltages? factor and output power. Use the approximate equivalent circuit
3. If the EMF in the stator of a six-pole induction motor has a frequency of 60 Hz, and that in 8. A three-phase 20-hp 220-V 60-Hz six-pole Y-connected squirrel-cage induction motor has the
the rotor of 2 Hz, at what speed is the motor running and what is the slip? following parameters per phase in stator terms: RS= , RR = , Xe = , Xm
4. A 3-phase, 460V, 100hp, 60HZ, four pole induction on machines delivers rated output power = . The rotational losses are 560W. For a slip of 3%, find
at slip of 0.05. determine: a. the line current and power factor
a. Synchronous speed and motor speed b. the horsepower output and shaft torque, and
b. Speed of the rotating air gap filed c. The efficiency.
c. Frequency of rotor circuit
d. Slip rpm
e. Speed of rotor filed relative to
i. Rotor structure
ii. Stator structure
iii. Stator rotating fields
f. Rotor induced voltage at operating speed if the stator to rotor turns ratio is 1:0.5
5. A 3-phase, 208V, 5hp, 60Hz, 1746 rpm induction on motor delivers rated output power. The
motor runs at 1800 rpm at no load. Determine:
a. The number of poles of machines
b. The slip at full load
c. The frequency of the rotor circuit

Das könnte Ihnen auch gefallen