INVERTER

IN-CEILING CASSETTE
Ideal for various applications including the lounge, family room, restaurants,
hotels, offices and meeting rooms.
INVERTER TECHNOLOGY PFC Control in Power Input

PFC Control in Power Input


DC Inverter Technology PFC Control in Power Input

With the advancement of inverter technology comes more quiet, economical


and powerful air conditioning systems. The LG air conditioner is Loss Full range
manufactured using PFC and sine wave technology.
Loss Full range
Step-up Inverter using PFC & Sine Wave Control Technology (PFC : Power
Factor Correction).
Sine wave Control in BLDC Compressor
Sine wave Control in BLDC Compressor

Sine wave Control in BLDCDCCompressor


280V DC 380V
(Boost up)

DC 280V DC 380V
(Boost up)
Partial switching Full range Sine wave switching

Partial switching Full range Sine wave switching

BLDC Fan Technology


The Brushless Direct Current (BLDC) motor is made up of
powerful ND magnets providing high torque, resulting in the
ability to provide large air volume and high static pressure
Permanent
capability. This allows high speed operation at reduced electrical Magnet
and mechanical noise.
Conductor

AC Motor BLDC Motor


Lower Efficiency Low Electrical and mechanical noise
Higher operating temperature Precise speed control
Difficult to precisely control fan speed Durable

Powerful BLDC Compressor


The LG inverter air conditioner comes with a BLDC compressor that uses
strong neodymium magnets. Its compressor has improved efficiency 1 Minimised Oil circulation
compared with AC inverter compressors. 1
2 High Efficiency Motor
3 Optimise Compression Efficiency 2

4 Optimise Vibration, Noise 3


5 High Reliability
4

Night Quiet Operation Night Sound


Night Quiet Operation is a control feature designed to reduce the noise Rated Sound
60 60
level of the outdoor unit at night.
The feature is activated via a dip switch+ on the outdoor PCB. 50 50
53 52
40 50
Noise Level [dB(A)]

+This function is not user adjustable, please contact your nearest AC installer. 48 48 40
Noise Level [dB(A)]

44 46 48 48
30 42 44
30 42

20
20
10
10

W18WH2 W24WH2 W36WH2 W48WH2


W18WH2 W24WH
INVERTER IN-CEILING CASSETTE
WIDE OPERATING RANGE
When cooling rooms in the event of low outdoor
temperatures, the BLDC inverter compressor and
outdoor BLDC fan motor are used to adjust the air
flow and volume, with a view to ensuring efficient
operation by allowing the air conditioner to keep
operating at -15C.

SLIM & COMPACT SIZE


The indoor unit with its slim and compact size enables installation in confined spaces.

Model Size
UTN24WH2 204mm

UTN18WH2 256mm

UTN36WH2 288mm

UTN48WH2 288mm

7.1 kW Model

4 VANE INDEPEDENT OPERATION


Vane angle control satisfies both users who like direct air or indirect airflow and it also reduces cold air drafts.

Direct air flow Indirect air flow Uniform vane operation Individual vane operation Individual vane angle control

HIGH CEILING OPERATION


Depending on the height of the installation, LG air
conditioners allow you to vary the speed of the indoor
fan motor.
When installation is low, the RPM can be reduced it can be
increased when the installation is high to ensure optimum
comfort levels. The speed can be adjusted via the slide switch
on the back of the LCD wired remote.

DESIGN TO REDUCE CEILING STAINS


The new outlet design can reduce ceiling Product Ceiling Product Ceiling
stains from air currents flowing along
the ceiling.
Ceiling
Louver pollutions Louver

Previous design Ceiling pollution prevention type with


latest design
LG AIR CONDITIONERS

WIDE JET AIR FLOW


Wide vanes reduce dead bands and Latest Technology t
26
27C
provide better air and temperature 80mm Wider! 25
24
23
567mm Even air distribution
distribution. 22
21
20
19
15C
18

t
Prevoius Technology 26
27C
25
487mm 24
23
Air flow dead zone 22
21
in 4 corners 20
19
15C
18

LOW NOISE DESIGN


BLDC motor, Low indoor noise with high Variable range of air flow noise of the indoor fan motor

efficiency turbo fan.


- Improved outlet & airflow design.
- Reduction of unnecessary noise through the BLDC Motor
high efficiency turbo fan design.
- Resonance noise reduction by anti-vibration
design & BLDC motor.
Attachable/detachable
corner design Fan setting
High Efficiency turbo fan
Refrigant Drain leakage Airflow variation
Piping check check

achable/detachable
corner design CONVENIENT PANEL INSTALLATION
Drain leakage
Hanger adjust Hanger adjust
The detachable corner
Attachable/detachable
corner design checkdesign makes it easy to adjust the hanger during installation and to check for leakages
in the drain connection pipe.
Drain leakage
check
Detachable Corner Design It is easy to install the panel to the body, using the lock tab panel design.

Hanger adjust

Refrigerant Hanger adjust Drain leakage


piping check check and
and hanger adjust hanger adjust

Hanger Hanger adjustDrain Leakage Check Hanger Adjust


adjust

ageDrain leakage
k check

Hanger adjust
ust DrainDrain Leakage
Leakage CheckCheck HangerHanger
AdjustAdjust
Drain Leakage Check Hanger Adjust

AUTO ELEVATION GRILLE


Easy filter cleaning with elevation grill. 4-Point Support Structure Auto Leveling

Memory for Users Level Auto Stop Detection


Max. 4.5m

STOP
Memory

* Operating with wired remote controller PQRCVSL0(QW) and wireless remote controller included in PTEGM0.
* Except UTN/8WH2
* Applied to cassette panel PT-UMC1
We at LG are committed to making the lives of our customers more
comfortable. Through continuous improvement in R&D and innovation
to enhance energy efficiency*, LG introduces the H2-Inverter, an energy
efficient, quiet unit giving you and your business comfort.

Innovation for a better life

*Excluding UT18Q2

Dimension (mm)
Capacity (kW) Indoor unit
Package Model Product Image EER/COP Sound Pressure
Cooling / Heating Dimension panel
(l/h/w)

UT18Q2
Indoor: UTN18WH2 570256570
4.7 / 5.5 3.13 / 3.48 41 / 39 / 36
Outdoor: UU18WH2 70022700
Front Panel: PT-UQC

UT24Q2
Indoor: UTN24WH2
840204840
Outdoor: UU24WH2 7.1 / 8.0 3.57 / 3.54 38 / 36 / 34
95025950
Front Panel: PT-UMC1

UT36Q2
Indoor: UTN36WH2 840288840
9.5 / 10.8 4.40 / 4.32 44 / 40 / 36
Outdoor: UU36WH2 95025950
Front Panel: PT-UMC1

UT48Q2
Indoor: UTN48WH2 840288840
13.4 / 15.5 3.51 / 3.73 45 / 41 / 38
Outdoor: UU48WH2 95025950
Front Panel: PT-UMC1

Wired Remote Controller


The wired remote controller features a large wide LCD screen which makes it easy for users to see
and use the digital operating controls.

Easy to read large font


Large wide LCD
Easy installation

PQRCVSL0(QW) Optional (PQWRHDF0)


Wireless Remote Controller
Specifications

Indoor UTN18WH2 UTN24WH2 UTN36WH2 UTN48WH2


Front Panel PT-UQC PT-UMC1 PT-UMC1 PT-UMC1
Power Supply /V/Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50
Cooling Min/Nom/Max kW 2.0 ~ 4.7 ~ 5.5 2.8 ~ 7.1 ~ 7.8 4.5 ~ 9.5 ~ 13.0 5.5 ~ 13.4 ~ 16.0
Capacity
Heating Min/Nom/Max kW 2.2 ~ 5.5 ~ 6.1 3.2 ~ 8.0 ~ 8.8 5.0 ~ 10.8 ~ 13.7 6.1 ~ 15.5 ~ 18.0
Running Current A 0.4 0.6 1.00 1.00
#1_Coil Row x Column x FPI mm (2 x 10 x 18) x 1 (2 x 8 x 19) x 1 (2 x 12 x 19) x 1 (2 x 12 x 19) x 1
Heat Exchanger
#1_Coil Row x Column x FPI mm - - (1 x 10 x 19) x 1 (1 x 10 x 19) x 1
Motor Output x Number of Unit W x No. 43 x 1 60 x 1 135.8 x 1 135.8 x 1
Fan
Air Flow Rate (H / M / L) m3/min 13.0 / 12.0 / 11.0 17.0 / 15.0 / 13.0 32.0 / 26.1 / 20.2 33.0 / 28.0 / 22.0
l/s 216 / 200 / 183 283 / 250 / 216 533 / 435 / 336 550 / 466 / 366
Body WxHxD mm 570 256 570 840 204 840 840 288 840 840 288 840
Dimensions
Decorative Panel WxHxD mm 700 22 700 950 25 950 950 25 950 950 25 950
Net Weight Body kg 15.5 20.5 28 28
Sound Level (H / M / L) dB(A) 41 / 39 / 36 38 / 36 / 34 44 / 40 / 36 45 / 41 / 38
Liquid mm 6.35 9.52 9.52 9.52
Piping Connection Gas mm 12.7 15.88 15.88 15.88
Drain (O.D. / I.D.) mm 32.0 / 25.0 32.0 / 25.0 32.0 / 25.0 32.0 / 25.0
Dehumidification Rate l/h 2.1 2.4 1.5 4.4
Referigerant R410 R410 R410 R410
Power and Communication Cable No.xmm 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75

Outdoor UU18WH2 UU24WH2 UU36WH2 UU48WH2


Cooling A 6.6 8.7 9.5 16.6
Running Current
Heating Nom A 6.9 9.8 10.8 18.0
Power Supply /V/Hz 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50 220-240 / 1 / 50
Power Supply Cable (includes Earth) No.xmm 3C x 2.5 3C x 2.5 3C x 5.0 3C x 5.0
Internuit Cable (Includes earth) No.xmm 4C x 0.75 4C x 0.75 4C x 0.75 4C x 0.75
Dimensions WxHxD mm 870655320 950834330 9501,380330 9501,380330
Net Weight kg 46.0 60.0 91.5 91.5
Oil Type FVC68D FVC68D FVC68D FVC68D
Compressor
Oil Charge cc x No. 900 x 1 900 x 1 1,300 x 1 1,300 x 1
Refrigerant Cycle Charge g 1,400 2,000 3,400 3,400
Additional Charging Volume g/m 20 40 40 40
Heat Exchange (RowxColumnxFins per inch)x No. mm (2 x 28 x 14) x 1 (2 x 38 x 14) x 1 (2 x 32 x 14) x 2 (2 x 32 x 14) x 2
Fan motor Output W x No. 85.4 x 1 124 x 1 124 x 2 124 x 2
Fan Air Flow Rate m/minxNo. 50 x 1 58 x 1 55 x 2 55 x 2
l/s 833 966 916 x 2 916 x 2
Air Circulation CMM 50 58 110 110
Sound Level (Max Power) dB(A) 60 62 66 68
Cooling Rated dB(A) 48 48 51 52
Sound Pressure Level
Heating Rated dB(A) 51 52 53 54
Max Piping Length m 40 50 75 75
Piping Elevation Difference IDU-ODU Max. m (ft) 30 30 30 30
Operation Range Cooling Min. ~ Max. C DB -15~48 -15~48 -15~48 -15~48
(Outdoor Temperature) Heating Min. ~ Max. C DB -18~18 -18~18 -20~18 -20~18

Australia Pty Ltd.


New South Wales / Head Office Western Australia New Zealand
2 Wonderland Drive EASTERN CREEK NSW 2766 Unit 1/1A 2 Business Way Malaga 6090 LG House Building 2, Level 1,
PH : 02-8805-4000 FAX : 02-8805-4248 PO Box 1724 Malaga WA 6944 60 Highbrooke Drive, Highbrook Business Park,
PH : 08-9249-3721 FAX : 08-9249-1300 East Tamaki, Auckland 2013 New Zealand
Queensland
South Australia PH : +64 (09) 914-2444 FAX : +64 (09) 914-2441
23 Terrace Place MURARRIE QLD 4172
PH : 07-3908-9000 FAX : 07-3399-4179 162 Richmond Road, MARLESTON SA 5033 Customer Service Helpline
PH : 08-3238-0200 FAX : 08-8238-0299 0800 54 2273 (0800 LG CARE)
Customer information Centre is available www.lg.co.nz
Victoria
7AM-7PM on 1300 54 2273 (1300 LG CARE)
3 John Deere Court, Parkwest Estate
www.lg.com.au/airconditioning
DERRIMUT VIC 3030
PH : 03-8369-0900 FAX : 03-9931-0677 CAMKPOSCASS_BROCH_15