Beruflich Dokumente
Kultur Dokumente
INF195
Infrared Thermometer
The INF195 is perfect for frequent use in advanced
or specialty application environments, where
wide temperature ranges and superior optics are
essential for use on targets at greater distances.
This full-featured infrared thermometer is the most
comprehensive and best-valued infrared thermometer
on the market.
Features:
-76~ 1022F (-60~ 550C)
12:1 Distance to spot ratio
MIN/MAX, Differential, Average
3 Emissivity levels: (0.30, 0.70, 0.95)
Hi/low alarm (user adjustable)
K-Type thermocouple input
Holster
1. 8 0 0 . 5 4 7. 5 7 4 0 W W W . U E I T E S T. C O M
INFRARE D TH ER M O M ETER S
INF165 INF195
Infrared Infrared
Thermometer Thermometer
INF165 INF195
Measurement range -36.4 to 689F (-38 to 365C) Item Non-contact Thermocouple Probe
Operating range 32 to 122F (0 to +50C) Infrared Scan
Accuracy (Tobj= 0 ~ 365C) +/-2.5% of reading or (2.5C) Measurement range -76 to 1022F -83.2 to +1999F
4.5F whichever is greater (-60 to +550C) (-64 to 1400C)
(Tobj -36.4 ~ 0C) (2.5C (4.5F)) Operating range 32 to 122F (0 to +50C)
+ 0.05/ per degree) Accuracy 2% RDG or 2C (4F) 1% of reading or 1.8F
Emissivity 0.70, 0.95 (Tobj= 0 ~ 550C) whichever is greater (1.0C) whichever is
Resolution (-9.9 ~ 199.9F) 0.2F/0.2C greater (Test under
Response Time (90%) 1 second (Tobj= -60 ~ 0C) ((2C (4F) Tamb=736F)
Distance Spot Ratio 12:1 + 0.05/per degree)
Battery life Standard AAA (x2) 1.5V, Resolution 0.1F / 0.1C
14 hours continuous (-9.9 ~ 199.9F)
Dimensions 6.9 X 1.5 X 2.8 Response time (90%) 1 second
Weight 6.3 oz including Distance: Spot 12 : 1
batteries Battery life Standard AAA (x2), 140 hours
2 AAA 1.5 batteries Dimensions 6.9 x 1.5 x 2.8 (175.2 x 39.0 x 71.9mm)
Weight 6.7 oz including batteries
NOTE: Under the electromagnetic field of 2V/m from 200 to 600 MHz, the maximum error is 18F (10C).
K-Type Temperature Probes (INF195)
ATT29 4 Standard fiber glass coated. (-40 to 950F / -40 to 510C)
ATT36 8 Surface probe and handle. (-40 to 950F / -40 to 510C)
ATT100 6 Liquid probe and handle. (-40 to 950F / -40 to 51
ATTPC2 1/4" ~ 1 1/2" Clamp Style Adapter for use with K-type inputs
ATTEXT 10 Extension for K-type thermocouples ATT29 ATT36 ATT100 ATTPC2 ATTEXT
D I G I TA L
NEW NEW
DTK2 DTK2KIT
Dual Input Differential
Digital Thermometer Temperature Kit
Specifications
DTK2
Temperature Range K-Type: -328F ~ 2498F (-200C ~ 1370C)
Temperature Unit C or F Selectable
Display Resolution 0.1C (0.1F)
Accuracy (0.2% + 1.4F) (0.2% + 1C)
Input Protection Max voltage of temperature input is 24V DC ATT29 ATT29A ATT100
Temperature Coefficient 0.01% of reading + 0.03C per C
0.01% of reading + 0.06F per F
When out of range 18C ~ 28C (64F ~ 82F)
Size 6 1/4 x 2 1/8 x x 1 1/2 (H x W x D)
DT15A DT20A
Single Input Dual Input
Digital Thermometer Digital Thermometer
DT15A, DT20A
Range Resolution Accuracy
G
COMIN
-50 to -20F/C 1
-19.9 to 199.9F/C 0.1
SOON!
(1% reading +1.5F/C)
200 to 571F 1
200 to 300C 1
Thermistors
ATT55A 4 Liquid temperature probe with 30 cord.
ATTPC3
Pipe Clamp
ATT56A 4 Air temperature probe with 30 cord. Thermistor
ATT57A 4 Surface temperature probe with 30 cord.
ATT58A Sealed probe with 15 cord.
1. 8 0 0 . 5 4 7. 5 7 4 0 W W W . U E I T E S T. C O M
T E M P E R A T U R E P R O B E S
J-Type Temperature Probes (for use with DT301, DT302, DT304 Digital Logging Themometers)
ATT19 48 Standard bead probe w/ clip. (-40-950F / -40-510C)
ATT26 8 Liquid probe and 48 cord. (-40-1,550F / -40-850C)
ATT27 48Standard bead probe. (-40-950F / -40-510C) ATT19 ATT26 ATT27 ATT30
ATT30 8 Liquid probe & handle. (-40-1,550F / -40-850C)
K-Type Temperature Probes
ATT29 Standard bead probe w/ 48 fiber glass coated wire.
(-40 to 950F / -40 to 510C)
ATT29A Standard bead probe w/ 48 fluoroplastic coated wire.
(-40 to 950F / -40 to 510C) ATT29 ATT29A ATT36 ATT37
ATT29APACK 10 PACK (ATT29A)
ATT36 8 Surface probe and handle. (-40 to 950F / -40 to 510C)
ATT37 8 Right angle surface probe and handle. (-40 to 950F / -40 to 510C)
ATT39 Storable bead probe w/ 36 fluoroplastic coated wire
for the DT301, DT302, DT304. (-40 to 950F / -40 to 510C)
ATT39 ATT50 ATT70 ATT100
ATT50 8 Liquid probe & handle. (-40 to 1,550F / -40 to 850C)
ATT70 Temperature plug adapter for DMMs and Clamp Meters.
ATT100 6 Liquid probe and handle. (-40 to 950F / -40 to 510C)
ATTPC 1/4" ~ 3" Pipe Clamp Adapter for use with K-type inputs.
ATTPC2 1/4" ~ 1 1/2" Clamp style adapter for use with K-type inputs.
ATTEXT 10 Extension for K-type thermocouples ATTPC ATTPC2 ATTEXT
G
Thermistors COMIN
SOON!
ATT55A 4 Liquid temperature probe with 30 cord.
ATT56A 4 Air temperature probe with 30 cord.
ATT57A 4 Surface temperature probe with 30 cord.
ATT58A Sealed probe with 15 cord.
ATT55A ATT56A ATT57A ATT58A ATTPC3
ATTPC3 1/4 ~ 1 1/2 Clamp style adapter for use with thermistor inputs.
We are proud to announce the opening of our newest service center located in Indianapolis. This provides the additional resources to respond quickly to
calibration, repair or warranty requests. All service shipments received at UEi are scheduled as normal turn around and prioritized as first come first serve to the
facility most able to complete the service turn around. Priority service is available by appointment only.
For a service request, please contact us:
Portland, OR Indianapolis, IN