GRATING / COVER AND FRAME
VENT COWL 10mm THICK TILE, 5mm THICK GLUE
2 mm THICK WATER PROOFING, SCREED SEDIMENT BUCKET
90mm (NOMINAL)
AS PER ARCHITECTURALSPECIFICATION
WATER PROOFING MEMBRANE
PROTECTIVE SHIELD FLASHING FITTING
(TYPICAL) EXTENSION PIECE
WEATHERING COLLAR ACCESS FOR CLEANING
CONTINUOUS PREFORMED SELF FFL Notes
PROTECTION SHEET MASTIC FILL
ADHESIVE FILLET
REFER TO ARCHITECTURAL
MASTIC COMPOUND
DETAIL DRAWING
CONCRETE ROOF
'500mm
PIPE SLEEVE TWO NOMINAL PIPE
SIZES LARGER THAN PIPE PASSING CONCRETE ROOF
THROUGH PIPE SLEEVE INLET OUTLET
STACK VENT MASTIC FILL
(DRY WASTE / SOIL STACK) PIPE
NOTE:
REFER TO ARCHITECTURAL DRAWINGS FOR WATER
PROOFING DETAIL AND ROOF FINISH DETAIL.
2-PIPES THROUGH CONCRETE ROOF DETAIL 3-FLOOR SINK DETAIL
Lead Consultant
4-FLOOR CLEANOUT DETAIL 5-FLOOR PIPE PENETRATION DETAIL 6-WASH BASIN DRAIN PIPE CONNECTION
DETAIL
GHD GLOBAL PTY LTD
3rd Floor, Guardian Tower, Danet Community
PO Box 45921 Abu Dhabi United Arab Emirates
T 971 2 6968700 F 971 2 4472915
E abumail@ghd.com W www.ghd.com
Specialist Consultant
O-LEAK FLANGE WELDED TO SLEEVE
6mm THICK STEEL PLATE
SEAL SLEVE WITH TIGHTLY
PACKED OAKUM
CENTRE PIPE IN SLEEVE
100
REFER TO ARCHITECT
FOR URINAL DETAIL
50mm VENT PIPE
JANITOR SINK GALVANIZED STEEL PIPE COAT EXTERIOR SURFACES Specialist Consultant
FAUCET SLEEVE POURED IN PLACE WITH TAR COMPOUND
UR
EXTERIOR WALLS Third Party
Operational Advisor
JANITOR SINK TERMINATED SLEEVE FLUSH WITH SEAL SLEVE WITH TIGHTLY
FINISHED WALL SURFACE PACKED OAKUM
SEAL OR CAULK SLEEVE THRU INSULATION BOTTL E TRAP
FIRE WALL IN TIGHT MANNER
1117
388
PIPE AND INSULATION TO BE
ARCHITECTURAL. DETAILS
CENTRED IN SLEEVE. DO NOT STATION
540