INTERNAL CALIBRATION PROCEDURE

Approved by: D.R.Vickers Date:2003


BMTS-CP-021, Issue 1, June 2003

INTERNAL CALIBRATION PROCEDURE AND RESULTS


Small Sampling Scoop measured against BS 812 : Part 102 : 1989

ITEM DETAILS
Bodycote Serial Number Description Range
Reference
Small Sampling Scoop N/A

Procedure

1. Equipment/Consumables required

REFERENCE EQUIPMENT REQUIRED/USED


Description Bodycote Reference Date of Last Calibration Stated
Uncertainty
Balance readable to 10g min.
accuracy.
Thermometer

2 Method
2.1 Visually check that the scoop is similar in shape to Figure 1 of the Standard.
2.2 Visually check the scoop for dents, accretions of concrete, whether handle firmly attached.
2.3 Take one scoop of Normal Density Fine Aggregate.
2.4 Weigh the Aggregate.
2.5 Repeat 2.3 and 2.4.

Results of Calibration

Mass or Dimension Measured Recorded Values Specification


1 2 Mean
Is the scoop similar in shape to Figure 1 of
Yes
the Standard?
Is the scoop in good condition (No dents,
accretions of concrete, handle firmly Yes
attached)?
Weight of Fine Aggregate (g) 1350 minimum*
* Standard states about 1.5kg of aggregate of normal density.

Date of Calibration Ambient Temperature (C)

Suitability for Use/Restrictions on Use


To be used for Fine Aggregate only.

Name of Operator Signature of Operator Checked by, Name Checked by, Signature

Page 1 of 1 BMTS- CP- 021 Issue 1

Das könnte Ihnen auch gefallen