Sie sind auf Seite 1von 44

NCRSelfServ26ATMSitePreparation

B0066641H000
NCRSelfServ26ATMSitePreparation

TheproductdescribedinthisdocumentisalicensedproductofNCR
Corporation.
NCRandNCRSelfServaretrademarksofNCRCorporation.Otherproduct
namesmentionedinthispublicationmaybetrademarksorregistered
trademarksoftheirrespectivecompaniesandareherebyacknowledged.
Wherecreationofderivativeworks,modificationsorcopiesofthisNCR
copyrighteddocumentationispermittedunderthetermsandconditionsofan
agreementyouhavewithNCR,NCR'scopyrightnoticemustbeincluded.
ItisthepolicyofNCRCorporation(NCR)toimproveproductsasnew
technology,components,software,andfirmwarebecomeavailable.NCR,
therefore,reservestherighttochangespecificationswithoutpriornotice.
Allfeatures,functions,andoperationsdescribedhereinmaynotbemarketed
byNCRinallpartsoftheworld.Insomeinstances,photographsareof
equipmentprototypes.Therefore,beforeusingthisdocument,consultwith
yourNCRrepresentativeorNCRofficeforinformationthatisapplicableand
current.

NCRProprietaryInformationnottobedisclosedorreproducedwithout
writtenconsent.

2008,2009,2010,2011,2012,2013
byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.
AllRightsReserved
B0066641H000
NCRSelfServ26ATMSitePreparation
Contents i
NormalOperatingRange(VestibuleEnvironment)......................... 52 GasResistantSecurityEnclosures................................................... 91
Introduction NormalOperatingRange(ExteriorEnvironment) ........................... 52 SecurityBolts........................................................................................ 92
Audience ...............................................................................................11 StorageRange(UpToThreeMonths) ............................................. 52 BoltHoles ............................................................................................. 92
AboutThisDocument ...........................................................................11 TransitRange(UpToOneWeek) .................................................... 52
CableEntry ........................................................................................... 92
NCRSitePreparationServicesContactInformation.............................11 ExtremePowerOnRange(UpToOneHour) .................................. 52
ChainGuardHoles................................................................................ 92
RevisionRecord ....................................................................................11 BarometricPressure ............................................................................. 52
HoleintheWall.................................................................................... 93
HoleatOptimumHeight ................................................................. 93
CustomerResponsibilities PowerRequirements HoleatLoweredHeight .................................................................. 93
Notice ...................................................................................................21 ACPowerRequirements....................................................................... 61 FaciaItems ........................................................................................... 94
InputVoltage ........................................................................................ 61 TopmostViewableFaciaItem ......................................................... 94
SiteCompliance ....................................................................................21
HeightsandDepths ......................................................................... 94
CustomerActions .................................................................................21 Grounding............................................................................................. 61
DistanceforVoiceGuidance ........................................................... 94
TransientProtection............................................................................. 61
ServicingAreasOptimum................................................................... 95
TransientProtectionProducts......................................................... 61
StandardsCompliance SingleATM ...................................................................................... 95
SideBySide ..................................................................................... 95
RadioFrequencyInterference ..............................................................31
FCCRadioFrequencyInterferenceStatement ................................31 CableRequirements ServicingAreasMinimum .................................................................. 96
CanadianClassADeviceDeclaration...............................................31 CablePreparation................................................................................. 71 SingleATM ...................................................................................... 96
SideBySide ..................................................................................... 96
Safety ....................................................................................................31 DataLineTransientProtection............................................................. 71
SafetyDirective................................................................................31 TransientProtectionProducts......................................................... 71 ClearancesCorridor............................................................................ 97
HarmonisedSafetyStandard...........................................................31 HighOrderCommunicationsStandardCable(RS232) ........................ 71 ClearancesExteriorWall .................................................................... 97
ElectromagneticCompatibility(EMC)...................................................31 StandardCollar................................................................................ 97
RS232Cable(9pin) ............................................................................. 71
ImmunityStandards ........................................................................31 AdvertCollar ................................................................................... 97
AlarmInterfaceCables ......................................................................... 72
EMCDirectives.................................................................................31 InternalSpaceConstraintforThirdPartyCamera ............................... 97
BasicAlarmCable ............................................................................ 72
EmissionStandards..........................................................................31 EnhancedAlarmCable .................................................................... 72
AdditionalRequirementsfor220V240VUnits .............................31 RemoteStatusMonitor ........................................................................ 73 VariantDetailsCEN,StandardSleeve
Accessibility ..........................................................................................31 ShorteningtheCable....................................................................... 73
HighestOperablePoint ...................................................................31 PackageDimensions........................................................................... 101
RemoteRelayCable.............................................................................. 73 ATMDimensions ................................................................................ 101
NCROptimumHeight ......................................................................31
EthernetStandardCable ...................................................................... 73 CENLandCENISecurityEnclosures ............................................. 101
LoweredHeights..............................................................................31
PowerCable.......................................................................................... 73 CENIIIandCENIVSecurityEnclosures ......................................... 101
CollarDimensions............................................................................... 101
ProductOverview StandardCollar.............................................................................. 101
GeneralDescription ..............................................................................41
Decals AdvertCollar ................................................................................. 101
Options ............................................................................................41 CardOrientationWindow .................................................................... 81 WeightandFloorLoading .................................................................. 101
Acoustics...............................................................................................41 AdvertDecalRecess ............................................................................. 81 StandardSecurityEnclosures........................................................ 101
WithoutCameraLens...................................................................... 81 GasResistantSecurityEnclosures................................................. 101
HeatDissipation....................................................................................41
WithCameraLens ........................................................................... 81 SecurityBolts...................................................................................... 102
ProductIdentification...........................................................................41
StandardCollarwithAdvertLight ........................................................ 81 BoltHoles ........................................................................................... 102
Entry/ExitDecals .................................................................................. 81 CableEntry ......................................................................................... 102
SiteRequirements DecalPlacement ................................................................................... 81 ChainGuardHoles.............................................................................. 102
PositioningtheATM .............................................................................51
HoleintheWall.................................................................................. 103
Floor......................................................................................................51 HoleatOptimumHeight ............................................................... 103
VariantDetailsCEN,ShortSleeve
DoorwaysandCorridors .......................................................................51 HoleatLoweredHeight ................................................................ 103
PackageDimensions ............................................................................. 91
Wall.......................................................................................................51 FaciaItems ......................................................................................... 104
ATMDimensions................................................................................... 91
InstallingThroughaGlassWall........................................................51 TopmostViewableFaciaItem ....................................................... 104
CENLandCENISecurityEnclosures ............................................... 91
WallCavity.......................................................................................51 HeightsandDepths ....................................................................... 104
CollarTolerance...............................................................................51 CENIIIandCENIVSecurityEnclosures............................................ 91
DistanceforVoiceGuidance ......................................................... 104
TaskLighting .........................................................................................51 CollarDimensions................................................................................. 91
ServicingAreasOptimum................................................................. 105
StandardCollar................................................................................ 91
AmbientLighting...................................................................................51 SingleATM .................................................................................... 105
AdvertCollar.................................................................................... 91
TemperatureandHumidity ..................................................................52 SideBySide ................................................................................... 105
WeightandFloorLoading .................................................................... 91
NormalOperatingRange(InteriorEnvironment)............................52 ServicingAreasMinimum ................................................................ 106
StandardSecurityEnclosures .......................................................... 91

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
Contents ii
SingleATM.....................................................................................106 HoleatLoweredHeight................................................................. 123
SideBySide....................................................................................106 FaciaItems.......................................................................................... 124
ClearancesCorridor ..........................................................................107 TopmostViewableFaciaItem ....................................................... 124
ClearancesExteriorWall...................................................................107 HeightsandDepths ....................................................................... 124
StandardCollar ..............................................................................107 DistanceforVoiceGuidance ......................................................... 124
AdvertCollar..................................................................................107 ServicingAreasOptimum ................................................................. 125
InternalSpaceConstraintforThirdPartyCamera .............................107 SingleATM..................................................................................... 125
SideBySide ................................................................................... 125
ServicingAreasMinimum................................................................. 126
VariantDetailsUL,ShortSleeve SingleATM..................................................................................... 126
PackageDimensions ...........................................................................111 SideBySide ................................................................................... 126
ATMDimensions.................................................................................111 ClearancesCorridor.......................................................................... 127
CollarDimensions ...............................................................................111 ClearancesExteriorWall .................................................................. 127
StandardCollar ..............................................................................111 StandardCollar.............................................................................. 127
AdvertCollar..................................................................................111 AdvertCollar..................................................................................127
WeightandFloorLoading...................................................................111 InternalSpaceConstraintforThirdPartyCamera ............................. 127
SecurityBolts ......................................................................................112
BoltHoles............................................................................................112
CableEntry..........................................................................................112
HoleintheWall ..................................................................................113
HoleatOptimumHeight ...............................................................113
HoleatLoweredHeight.................................................................113
FaciaItems..........................................................................................114
TopmostViewableFaciaItem .......................................................114
HeightsandDepths .......................................................................114
DistanceforVoiceGuidance .........................................................114
ServicingAreasOptimum .................................................................115
SingleATM.....................................................................................115
SideBySide....................................................................................115
ServicingAreasMinimum.................................................................116
SingleATM.....................................................................................116
SideBySide....................................................................................116
ClearancesCorridor ..........................................................................117
ClearancesExteriorWall...................................................................117
StandardCollar ..............................................................................117
AdvertCollar..................................................................................117
InternalSpaceConstraintforThirdPartyCamera .............................117

VariantDetailsUL,StandardSleeve
PackageDimensions ...........................................................................121
ATMDimensions.................................................................................121
CollarDimensions ...............................................................................121
StandardCollar ..............................................................................121
AdvertCollar..................................................................................121
WeightandFloorLoading...................................................................121
SecurityBolts ......................................................................................122
BoltHoles............................................................................................122
CableEntry..........................................................................................122
HoleintheWall ..................................................................................123
HoleatOptimumHeight ...............................................................123

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
Introduction 11
AUDIENCE NCRSITEPREPARATIONSERVICESCONTACTINFORMATION REVISIONRECORD
Thisdocumentisintendedforarchitectsandthoseresponsibleforpreparinga FormoreinformationfromNCRsSitePreparationServicesgrouponthe
Date Revision Pages Reason for Change
sitepriortothearrivaloftheATM. availabilityofpowerprotection,datalinetransientsuppressors,uninterruptible
powersupplyproducts,warrantyorconfigurationassistance,callthe May 2010 C Inside front Updated EMC and NCR address.
cover
appropriatenumberbelow: Back pages Added revision record.
ABOUTTHISDOCUMENT Contact information changed.
Region Telephone 1 Added dimensions rounding note.
Thedocumentisorganisedintosectionscoveringthefollowingtopics: Added note regarding Vestibule and Through the Wall
USA and Canada +1 800 257 0458
dimensions.
Introductionthissection Europe, Middle East and Africa +97 1501405904 or 919-228-2412 (US)
2 Updated reference to Site Requirements.
CustomerResponsibilities Caribbean and Latin America +55 21 2540 0058 Various Added CEN Grade IV ECBS Security Enclosure.
StandardsCompliance Asia Pacific +91 93-80291285 15, 18, 46 Added Contactless Card Reader.
48 Removed opaque panel decal - not available on this
ProductOverview product.
SiteRequirements February 2011 D 31 Updated Lowered Heights section.
PowerRequirements 37 Updated CEN IV weight and floor loading.
Various Removed references to ECBS and Spanish Certified.
CableRequirements Various Updated ADA plinth heights. Removed ADAAG.
Decals Various Restructured installation heights section for clarity.
VariantDetailsCEN,ShortSleeve May 2011 D 21-26 Updated average CE figure size.
VariantDetailsCEN,StandardSleeve January 2012 E 16 Added Contactless Card Reader behind Facia to table.
September 2012 F 36 Added CEN III, CEN IV Rear Access Gas Resistant
VariantDetailsUL,ShortSleeve
44 variants.
VariantDetailsUL,StandardSleeve Removed reference to obsolete publication (ATMs
47 Feature Descriptions (B006-6451)).
Eachpagehastwoorthreecolumnslaidoutasfollows: 25, 26 Removed references to panel illumination.
Publication name Section name Section number Page number Added Note 3 for dispenser racking out further than
clearance.
April 2013 G All New A3 format.
Added all requirements from NCR SelfServ 22, 22e,
25, 26, 28, 31, 36 Site Preparation Requirements,
B006-6669.
9-2, 10-2, Updated security bolts specifications.
11-2, 12-2
July 2013 H Title Updated logos
3-1 Moved Immunity Standards from Safety to EMC
6-1 Updated Grounding
Column 1 Column 2 Column 3

Copyright Publication ID

WhereleftandrightsidearestatedtheATMisviewedfromthefront(facia
side)oftheATM.Allplanviewsaretopdownunlessotherwisestated.
Unlessotherwisestatedalldimensionsareroundedtothenearestmillimetre
andequivalentdecimalofaninch.

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
CustomerResponsibilities 21
NOTICE SITECOMPLIANCE CUSTOMERACTIONS
Thisisacontractualdocument.Itcontainsimportantwarningsandconfers Thisdocumentcontainstheinformationnecessaryforthepreparationofasite Thecustomermustdoorprovidethefollowing:
importantlegalrightsandobligations.Youareadvisedtoreaditcarefully. conformingtoNCRspecifications.Itisveryimportantthatthesitecomplies
WhenrequiredbyNCR,providetheNCRcustomerservice
withtherequirementsspecifiedinthisdocument,because,oncethe
Itistheresponsibilityofyou,thecustomer,toassurethatallinstallation representativewithappropriatedrawingsthatindicate:
equipmenthasbeeninstalled,deficienciesinsitepreparationortheproblems
preparationsarecompleteandincompliancewithallspecificationsand Locationoftheequipment
causedbythesedeficienciesaremuchmoredifficulttodetectandcorrect.
requirementsofNCRandallapplicablenational,state,orlocalcodes, Sitewiring(powerandsignal,pathsandlengths)
regulationsandlaws. Further,failuretocomplywiththeserequirementsortotakeproperstepsto
Locationofotherequipmentcapableofgeneratingelectricalnoise,
protectequipmentagainstrisksidentifiedinthisdocumentmaycauseserious
Thisequipmentmustbeinstalledandusedinstrictaccordancewiththe electromagneticinterference,heat,etc.
damagetotheequipmentandtothecustomersbusiness.
manufacturersinstructions.However,thereisnoguaranteethatinterference Makebuildingalterationsnecessarytomeetwiringandothersite
toradiocommunicationswillnotoccurinaparticularcommercialinstallation.If Inadditiontotheneedtocomplywiththerequirementsspecified,electrical requirements.
thisequipmentdoescauseinterference,whichcanbedeterminedbyturning wiringandmechanicalsystemsmustalsocomplywithallrelevantcodes,laws Provideandinstallallcommunicationscables,walljacks,special
theequipmentoffandon,theuserisencouragedtoconsultanNCRservice andregulations. connectors,andassociatedhardware.
representativeimmediately.
Itisimportantthatthesitebepreparedbyacustomerorhisagentwhoisfully Provideandinstallnecessarypowerdistributionboxes,conduits,
conversantwiththespecialrequirementsofelectronicequipment.The grounds,lightningprotection,andassociatedhardware.
responsibilityforensuringthatthesiteispreparedincompliancewiththis Makesureallapplicablecodes,regulationsandlaws(including,butnot
CAUTION NCRCorporationisnotresponsibleforanyradioortelevision documentremainswiththecustomer. limitedto,electrical,building,safety,andhealth)aremet.
interferencecausedbyunauthorizedmodificationsofthis Forinformationandguidancepurposesonly,alistisprovided,ingeneralterms, Provideandinstallauxiliarypowerorotherequipmentasrequired.
equipmentorthesubstitutionorattachmentofconnectingcables ofthosemattersforwhichthecustomerisresponsible.Thislistisnotintended Providestorageorserviceareasasrequired.
andequipmentotherthanthosespecifiedbyNCR.Such tobecomprehensive,andinnowaymodifies,alters,orlimitstheresponsibility Makesuretheenvironmentalrequirementsofthesystem/unitaremet.
unauthorizedmodifications,substitutions,orattachmentsmay ofthecustomerforallaspectsofadequatesitepreparation.
voidtheusersauthoritytooperatetheequipment.Thecorrection Providefloorcoveringsandenvironmentalsystemsthatlimitorcontrol
ofinterferencecausedbysuchunauthorizedmodifications, NCRstaffwillbeavailabletoanswerquestionsrelatingtothecontentsofthis staticelectricitybuildupanddischarge.
substitutions,orattachmentswillbetheresponsibilityoftheuser. documentbut,exceptwhere: Installtheproductataheightwhichmeetstheaccessibilityregulations
oftherelevantcountry.
a. thecustomerhasbeennotifiedthatafullorpartialconsultancyservice
isavailableand/orthatNCRwillbewillingtoundertakeapreliminaryor
finalsitesurveyand
b. thecustomershallhaveenteredintoaformalcontractwithNCRfor
provisionofthesame
nocomment,suggestionoradviceofferedornotofferedaboutpreparationof
thesitenoranyinspectionofthesitewhetherbeforeorafterpreparationisto
betakenasapprovalofthelocationofthesiteandequipmentorofits
preparationandNCRwillnotbeliableinrespectofanycomment,suggestionor
advicegivenbyitsstafforinrespectofanyfailuretogiveadvice.
Finally,onlythecustomercanknowthefullextentofdamagewhichmaybe
causedtohisbusinessbyreasonoffailureoftheequipmentwhichistobe
installed.Forthisreasonitisthecustomersresponsibilitytoascertainthe
extentofanysuchpossibledamagetohisexistingorplannedbusiness,andto
effect,fullinsuranceinrespectofit.

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
StandardsCompliance 31
RADIOFREQUENCYINTERFERENCE ELECTROMAGNETICCOMPATIBILITY(EMC) ACCESSIBILITY

FCCRadioFrequencyInterferenceStatement ImmunityStandards HighestOperablePoint


ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass TheATMcomplieswiththefollowingrequirementsforradiatedandconducted Thehighestoperablepointistheheightoftheofthehighestconsumer
Adigitaldevice,pursuanttoPart15oftheFederalCommunications immunity: interfaceelementwhentheATMisinuse.ThetopFDKofthe15.0inchdisplay
Commission(FCC)Rules.Theselimitsaredesignedtoprovidereasonable isconsideredtobethehighestoperablepointofthisATM.Providingthatthe
EN55024(1998)/+A1:2001,A2:2003
protectionagainstharmfulinterferencewhentheequipmentisoperatedina softwareapplicationisdesignedtoNCRguidelinesthispointalsoappliesforthe
commercialenvironment.Thisequipmentgenerates,uses,andcanradiate AspertherequirementsofEN55024,theATMcomplieswiththerequirements touchscreenvariant.
radiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe ofthefollowingnormativeImmunityStandard:
Note: Ifa12.1inchdisplayisfitted,theFDKsandtouchscreenarelowered.In
instructionmanual,maycauseharmfulinterferencetoradiocommunications. EN6100042ElectrostaticDischarge
thiscasethehighestoperablepointisloweredby43mm(1.70in.).
Operationofthisequipmentinaresidentialareaislikelytocauseharmful
EN6100043RadiatedRF Otherinterfaceelementsremainatthesameheight.
interferenceinwhichcaseyou,thecustomer,willberequiredtocorrectthe
interferenceatyourownexpense. EN6100044ElectricalFastTransient/Burst
EN6100045Surge NCROptimumHeight
EN6100046ConductedRF
CanadianClassADeviceDeclaration Thisheightassuresthebestdisplayviewabilityforablebodiedpeople.Itdoes
EN6100048PowerFrequencyMagneticField
NOTcomplywiththeregulationslistedintheLoweredHeightssection.
ThisdigitalapparatusdoesnotexceedtheClassAlimitsforradionoise EN61000411VoltageDips/ShortInterruption.
emissionsfromdigitalapparatussetoutintheRadioInterferenceRegulations NCROptimumHeightspecifiesthehighestoperablepointtobe1400mm
oftheCanadianDepartmentofCommunications. (55.12in.)fromsidewalklevel.Thisplacestheheightoftheno.5keyat
EMCDirectives 1115mm(43.90in.)fromthesidewalk.
Leprsentappareilnumriquenmetpasdebruitsradiolectriquesdpassant
leslimitesapplicablesauxappareilsnumriquesdelaclasseAprescritesdansle Thisequipmenthasbeenfoundtocomplywiththeessentialrequirementsof
Rglementsurlebrouillageradiolectriquedictparleministredes EMCDirective2004/108/EC,bytestingtoharmonizedstandard,EN55022and LoweredHeights
CommunicationsduCanada. EN55024.TheequipmentcomplieswiththelimitsforaClassAdigitaldevice,
pursuanttoEN55022. Theloweredinstallationheightsaredesignedtomeettheregulationsbelow
andthereforeaccommodateusebybothablebodiedanddisabledpeople.
TheATMcomplieswiththefollowingElectromagneticCompatibility(EMC)
SAFETY directivesandstandardsforITequipment: Loweredheightsarespecifiedforthefollowingregulations:

2004/108/ECEMCDirective (UK)AccesstoATMs:UKDesignGuidelines2002,CentreforAccessible
SafetyDirective 93/68/EECCEMarkingDirective Environments
(US)DepartmentofJusticeStandardforAccessibleDesign,TitleIII,(ADA
73/23/EEC,93/68/ECCLowVoltageDirectiveandAmendment. 2010)
EmissionStandards (CAN)CAN/CSAB651.109BarrierFreeDesignforAutomatedBanking
HarmonisedSafetyStandard TheATMcomplieswiththefollowingrequirementsforradiatedandconducted Machines(CSA).
emissions: InadditiontoCAE,ADAandCSA,theATMisdesignedtoalsomeetthe
EN609501:2006InformationTechnologyEquipmentSafety
EN55022(1998)ClassA followingregulations:
FCC47CFRPart15.ClassA (AUS)AS3769AustralianStandard(AS3769).
CISPR22ClassA (AUS)AustralianBankersAssociation(ABA)IndustryStandard,
AS/NZS3548ClassA AutomaticTellerMachines(ATMs).2004
GB9254ClassA (FRA)MinistredeLEmploi,delaCohsionSocialeetduLogement,
CNS13438ClassA. Aug24,2006,whichmodifiesCodedelaConstruction,articlesR.11119
toR.111193andR.111196

AdditionalRequirementsfor220V240VUnits Theheightslistedinthisdocumentassumenoadditionaldepthhasbeenadded
bytheinstallation.Increaseddepthmaychangetheheightrequirements,
TheATMcomplieswiththefollowingrequirementsforconductedemissions: thereforepleaserefertotherelevantaccessibilityregulationwhereadditional
EN6100032:2000,Mainsharmonics,ClassA depthhasbeenadded.
EN6100033:1995/+A1:2001,Mainsflicker. Note: Itistheresponsibilityoftheowninginstitutiontoensurethatthe
heightsfromthesidewalkleveltothefaciaitemscomplywithanylocal
regulations.

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
ProductOverview 41
GENERALDESCRIPTION ACOUSTICS PRODUCTIDENTIFICATION
TheNCRSelfServTM26AutomatedTellerMachine(ATM)isathroughthewall Formostvariantstheacousticssoundpowerdoesnotexceed: Theillustrationbelowistypicalofthelayoutoftheproductidentificationlabel
ATMwhichmaybeinstalledthroughanysuitableexteriorwallorinavestibule whichisfixedinsidetheATM.
65dB(A)whenidle
location.
68dB(A)whenoperating

HEATDISSIPATION
TheNCRSelfServproductrangeisaflexiblehardwareplatform.NCR
recommendsthatactualpowermeasurementsaretakenandusedtoestablish
theheatdissipationforspecifichardwareconfigurations.Thesemeasurements
shouldincludeanycustomorthirdpartyfeatures.
Wherespecificmeasurementsarenotavailablethen,asaguide,760KJ/hour
canbeusedasanindicativeheatingload.ThisfigureisbasedonanATMinidle
mode,withamediumtohighfeaturefunctionalityconfiguration.
Heatdissipationfiguresarelargelyunaffectedbytransactionalrates.

Theproductisidentifiedbyaclassanda4digitmodelnumber.Theserial
TherearenoseparateVestibuleorThroughtheWallvariantsoftheSelfServ26. numberisuniquetoeachATM.Thetracernumberisusedtoidentifywherethe
Alldimensionsandclearancesarethesameforbothtypesofinstallation. ATMwasbuilt.
Pleasequotealloftheserialandtracernumbers,includingtheprefix,when
Options makingreferencetotheATM.

SecurityEnclosure Electricalratinginformationisalsoshownontheproductlabel.
CENL

CENI

CENIII

CENIV

UL291Level1

Sleeve
ShortSleeve
StandardSleeve

Collars
StandardCollar
AdvertCollar

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
SiteRequirements 51
Thecollarcannotaccommodatelargedipsordepressionsinthewall.Make
POSITIONINGTHEATM WALL surethewallissmoothandeven.
TheATMmaybeinstalledthroughanysuitableexteriorwallorvestibule A25mm(1.0in.)widesmoothsurfaceisrequiredaroundtheedgeofthewall
location. openingtoenableagoodweatherseal.
+/- 4 mm
TheATMmustalsobepositionedawayfromheatsourcesoranyair (0.2 in.)
conditioningequipment. InstallingThroughaGlassWall
Brightlightsandwindowsbehindtheusermaydegradecameraperformance. IfyouareinstallingyourATMthroughaglasswallyoumayrequireasuitable
PositiontheATMawayfromdirectsunlight. glasssupport(normallyasteelcollar)tositbetweentheATMcollarandthe 0.0 mm
glass.Therequirementforthissupportshouldbedeterminedbythearchitect. (0.0 in.)
Allowsufficientroomforinstallationandservicingrequirements.
Ifrequired,anysuchsupportshouldbesourcedlocally.

FLOOR WallCavity +/- 4 mm


(0.2 in.)
TheATMmustbeinstalledonalevel,even,concreteorothernoncombustible Anycavityinthewallmustbesealedatinstallationtimetoprovideaflush
surface.Inlocationswherethefloormaybeuneven,itisrecommendedthata surfacethatdoesnotextendintothewallopening.Leavethegapbetweenthe
steelplateisusedundertheATM. ATMsleeveandthewallopeningcleartoallowairatroomtemperatureto
Anantistaticfloorcoveringshouldbeusedandmustbeofatypethatwillnot circulate.
generatedustorfluff.
TheATMmustbeinstalledonafloorcapableofsupportingthemaximum
weightincludingmedia.Onlythemaximumweightshouldbeconsideredas
additionaloptionsmaybeaddedafterinstallation.Floorloadingiscalculatedby
dividingthemaximumweightoftheATMbythesurfaceareaoftheATMbase TASKLIGHTING
incontactwiththefloor.
Aminimumof200LUXisrequiredfortasklighting.
Serviceareas,ATMweightsandfloorloadingcanbefoundintheVariantDetails
sectionforyourATM.
AMBIENTLIGHTING
DOORWAYSANDCORRIDORS IftheATMisfittedwithacamera,itisstronglyrecommendedthatthereisa
minimumof50LUXlightingatfloorlevelwithintheareaillustratedbelow.
Makesurethatdoorwaysandcorridorsleadingtoyourpointofinstallationare
wideenoughtoallowthepackagetopassthrough,ormakearrangementsto
unpacktheATMandremoveitfromthepaletteinanareawithsufficient
accessthenmoveittotheinstallationsite.
MakesurethatanycorridorscansupporttheweightoftheATM,includingall
packagingandthepallet.
CorridorsizesandATMweightscanbefoundintheVariantDetailssectionfor
yourATM. CollarTolerance
Thecollarhasatoleranceof+/4mm(0.2in.(+/0.5))atthetopandbottom,
with0mm(0.0in.(0))atitscentre.

1000 mm
(39.40 in.)

1500 mm
(59.06 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
SiteRequirements 52
TEMPERATUREANDHUMIDITY BAROMETRICPRESSURE
Continuousoperatingatorneartherangelimits,orinalocationwherethe Operating/TransitLimits:105kPa(15.2lb.F/in.)to70kPa(10.2lb.F/in.)
temperatureandhumiditychangebeyondthespecification,shouldbeavoided. EquivalentAltitude:Uptoamaximumof3000m(9842.52ft)
Ifinstallingthoughanexteriorwall,thesitemustmeettherequirementsof
boththeInteriorandExteriorenvironments.
Note: ForexteriorthroughthewallATMsthehumidityinsidethebuildingis
restrictedtoamaximumof30%atanoutsidetemperatureof
35C(31F),withalinearrelationshipbetweentemperatureand
humiditytoamaximumhumidityat0C(32F).

NormalOperatingRange(InteriorEnvironment)
Temperature:
o o o o
withoutSevereEnvironment:10 Cto40 C(50 Fto104 F)
o o o o
withsevereenvironmentfitted:0 Cto40 C(32 Fto104 F)

RelativeHumidity:20%to80%
DewPointTemperatureRestriction:26oC(79oF)maximum

NormalOperatingRange(VestibuleEnvironment)
Temperature:0oCto50oC(32oFto122oF)
RelativeHumidity:10%to100%
DewPointTemperatureRestriction:26oC(79oF)maximum

NormalOperatingRange(ExteriorEnvironment)
Temperature:35oCto50oC(31oFto122oF)
RelativeHumidity:10%to100%
DewPointTemperatureRestriction:26oC(79oF)maximum

StorageRange(UpToThreeMonths)
Temperature:10oCto50oC(14oFto122oF)
RelativeHumidity:10%to90%

TransitRange(UpToOneWeek)
Temperature:40oCto60oC(40oFto140oF)
RelativeHumidity:5%to95%
Note: Ifanuninterruptiblepowersupply(UPS)isfittedtotheATM,the
temperatureduringtransitshouldnotdropbelow15oC(15oF).

ExtremePowerOnRange(UpToOneHour)
Temperature:0oCto45oC(32oFto113oF)
RelativeHumidity:10%to95%

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
PowerRequirements 61
ACPOWERREQUIREMENTS TRANSIENTPROTECTION TransientProtectionProducts
Themaximumcurrentrequirementsare: Intheprocessofpowerdistribution,transientelectricalenergy(including,but NCRprovidesafullrangeofbothACpoweranddatalinetransientsurge
notlimitedto,lightningstrikes,intermittentshortcircuits,andswitching suppressorstoprotectyourATM.Formoreinformation,pleasecallNCRSite
10Aat120V PreparationServicesformoreinformation.
transients)canbeintroducedontopowerlines.Suchtransientenergycanbe
6.3Aat230V. verydamagingtoelectronichardwareandcanalsocausedatacorruption. NCRSitePreparationServicesContactInformationislistedintheIntroduction
Themaximuminrushcurrentis100A. Underthesecircumstances,NCRrecommendstheuseofACpowertransient section.
suppressorsanddata(communication)linetransientsuppressors.Such
NCRdoesnotrecommendrunninganATMwithdepositdeviceswithoutan
protectivedevicesareintendedtoguardagainstpoweranddatalinetransients
UninterruptiblePowerSupply(UPS).WithoutaUPS,thereisthepotentialfor
thatcanresultinhardwaredamageandvarioussystemorprogramerrors.
customerscashtoberetainedinthedeviceifthereisapowerfailure.
Improvementofanydeficienciesinpowerqualityisacustomerresponsibility.
Malfunctionand/orcomponentfailureasaresultofpowerqualityproblems
INPUTVOLTAGE are/isnotcoveredbyNCRCorporationMaintenanceAgreement.NCRaccepts
noliabilityforanysuchoccurrencenorforitsconsequences.
TheATMcanoperatefromthefollowinginputmainsvoltages:
Whenpowertransientsuppressionisrequired,thesuppressorsusedshould
90Vto136Vat50/60Hz meetthefollowingminimumrequirements:
180Vto264Vat50/60Hz.
Dissipateenergytomatchtheappropriateapplicationcategoriesas
definedbyANSI/IEEEStandardC62.41,GuideonSurgeVoltagesinLow
VoltageACPowerCircuits.
GROUNDING
Beofthevoltagelimiting(clipping),ortrackingfiltertype.The
TheATMoperatesfromasinglephase,3wiresupply:live,neutralandground. suppressormustnotclampthevoltagetozero,andmustselfrecover
afterthepassageofthetransient.Thesuppressormaybeofthehybrid
TheATMpowerrequirementswillnormallypermitittooperatewithinexisting
typeconstructionthatmakesuseofvarioustechnologiesinorderto
wiringconfigurationsandfromexistingmainsoutletsprovidedthat:
meetspeedanddissipationrequirements.
thebranchcircuitofthedistributionpanelsupportingtheATMisnot Exhibitashortcircuitmodeuponitsfailure,thusprovidingapositive
alsousedtosupportequipmentwithheavyinductiveloadssuchasair indicationofitsfailuresuchasablownfuseortrippedbreaker
conditionersorACmotors. Belistedbytheacceptedsafetyorganizationforthecountryinvolved
otherbranchcircuitsonthesamedistributionpaneldonotsupport (e.g.UL,CSA,VDE,ETL,etc.)andtheinstallationmustconformtolocal,
suchequipment. state,andnationalelectricalcodesandregulations.
theinstallationmeetsorexceedstheregulatoryandlocalguidelines
withregardtoelectricalsafetyandallconductorsizing. Comparable to IEC
Location Category Transient
No 664 Category
ThenormalandsafeoperationofthisATMisdependantontheabove.Only
Waveform Amplitudes
qualifiedpersonnelthatmeetlocalcertificationstandardsshouldbepermitted
toensurecompliance. Volts = 1.2 x 50 s 6kV
Current = 8 x 20 s 3kA
Notethatthebuildinggroundpointcanalsoaffectdataintegrity.Foradditional B = Major feeders, short branch
III and
circuits, and load centres
informationrefertoDataLineTransientProtectionintheCableRequirements 0.5 Rise - 100 kHz 6kV
section. Ringwave 500A
C = Service Entrance and run to Volts = 1.2 x 50 s 10kV or more
IV
load centre Current = 8 x 20 s 10kA or more

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
CableRequirements 71
CABLEPREPARATION HIGHORDERCOMMUNICATIONSSTANDARDCABLE(RS232) RS232CABLE(9PIN)
NCRsupplyapowercablefortheATM.Otherexternalcablesarenotsupplied. Theinterconnectingcabletotheremotemodemshouldnotexceed12.2m TheATMcanhaveuptotwoRS232(9pin)outlets.Thecableforeachoutlet
Specificationsforthesecablesaregiveninthissection. (40.0ft)inlengthandmustconformtothefollowingspecification: shouldnotexceed12.24m(40.16ft)andmustconformtothefollowing
1, 2, 5, 6 4 specification:
Itisthecustomersresponsibilitytohaveanyrequiredexternalcablesinstalled
andtomakesurethatallcablepreparationscomplywithNCRspecificationsas 1, 2 4
3 3
wellaswithallnational,stateorlocaltelephoneandtelegraphregulationsand
laws.
Whenproducingcablesallowfor2.4m(7.9ft)ofcablewithintheATM.

DATALINETRANSIENTPROTECTION 1. Connector, 25 Way (NCR part no. 006-0005897)


2. Terminal, wire, male (NCR part no. 009-0002642) 1. Connector, 9 Way (NCR part no. 006-0010488)
Voltagetransients,linenoise,surges,sags,impulses,andspikesmaybe 3. Cable, multiconductor (NCR part no. 007-8907033). 2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, shielded multiconductor (NCR part no. 007-8907033).
experiencedroutinelyorsporadically.Whensuchphenomenaoccurtheuseof 4. Connector (determined by remote device).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006-1500038).
protectivedevicesmayberequiredtoensureproperoperationofthe 6. Screw retainer (NCR part no. 601-0101584).
equipment.
Itistheresponsibilityofthecustomertoinstallandconnectadataline 1 Chassis GND
1 DCD
transientsuppressionsystemtocorrectorpreventanydeficiencies.Such 2 TD.V
2 RXD
3 RD.V
systemsmustmeetthefollowingminimumrequirements: 3 TXD
4 RQS.V
4 DTR
Beoftheselfrecoveringvoltagelimitingtype.Exhibitashortcircuitmode 5 RFS.V
5 SIG. GND
uponitsfailuretoensureapositiveindicationofitsfailure.Insertminimum 6 DSR.V
6 DSR
inductiveandcapacityloadingattheoperatingfrequency.Beinstalledin 7 SIG.GND
7 RTS
8 RLSD.V
accordancewithallapplicablelocal,state,andnationalelectricalcodesand 8 CTS
9 Not used
regulations. 9 RI
10 Not used

Protectthedataportfromdamageinthepresenceofadatalinetransient 11 Not used


12 Not used
Removea40mm(1.6in.)sectionoftheoutersleeve,2.0m(6.6ft.)fromthe
eventasdefinedinIECStandard100045(formerlyIEC8015).
13 Not used
14 Not used
ATMendofthecable.
15 TSET.V Takecarenottocutthroughthecableshielding.
TransientProtectionProducts 16 Not used
NCRprovidesafullrangeofbothACpoweranddatalinetransientsurge 17 RSET.V
18 WCA.V 40 mm
suppressorstoprotectyourATM.Formoreinformation,pleasecallNCRSite (1.6 in.)
19 Not used
PreparationServicesformoreinformation.
20 DTR.V
NCRSitePreparationServicesContactInformationislistedintheIntroduction 21 Not used

section. 22 CI.V
23 Not used
24 EXT SET.V
2.0 m
25 WIN.V (6.6 ft.)

Removea40mm(1.6in.)sectionoftheoutersleeve,1.8m(5.9ft.)fromthe
ATMendofthecable.
Takecarenottocutthroughthecableshielding.
40 mm
(1.6 in.)

1.8 m
(5.9 ft.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
CableRequirements 72
ALARMINTERFACECABLES BasicAlarmCable EnhancedAlarmCable
TheATMmayoptionallybeconfiguredtoprovideanalarminterfacewhich
enablestheATMtobeconnectedtoanexternallocalalarmsystem.The 1, 2, 5, 6 4 1, 2, 5, 6 4
interfacemaytaketheformofoneoftwooptions;abasicalarmsystemoran
enhancedalarmsystem. 3 3

Astabilised,noninterruptiblepowersupplymustbeprovidedthroughthe
externalalarmsystem.Thealarminterfacecablewiringmustconformtothe
followingspecification:
12V+/2Vdc
200mAmaximum 1. Connector, 25 Way (NCR part no. 006-0005896) 1. Connector, 25 Way (NCR part no. 006-0005896)
Ripple,5%maximum. 2. Terminal, wire, female (NCR part no. 009-0002640) 2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed). 3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device). 4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006-1500038). 5. Shell Hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584). 6. Screw retainer (NCR part no. 601-0101584).

1 Chassis GND 1 Chassis GND


2 Not used 2 Not used
3 Not used 3 Test Transmitter A
4 Not used 4 Not used
5 Not used 5 Tamper Alarm N.O.
6 Not used 6 Tamper Alarm N.C.
7 Sient Alarm Common 7 Silent Alarm Common *
8 Door Alarm N.O. 8 Door Alarm N.O.
9 Door Alarm N.C. 9 Door Alram N.C.
10 Vibration/Heat Common 10 Composite Attack Common
11 Not used 11 Not used
12 +12 V 12 +12 V
13 Not used 13 Not used
14 Not used 14 Not used
15 Not used 15 Not used
16 Not used 16 Test Transmitter B
17 Not used 17 Not used
18 Not used 18 Tamper Alarm Common
19 Silent Alarm N.O. * 19 Silent Alarm N.O. *
20 Silent Alarm N.C. * 20 Silent Alarm N.C. *
21 Door Alarm Common 21 Door Alarm Common
22 Vibration/Heat N.O. 22 Composite Attack N.O.
23 Vibration/Heat N.C. 23 Composite Attack N.C.
24 Not used 24 Not used
25 +12 V Return 25 +12 V Return

*Optional *Optional

Removea40mm(1.6in.)sectionoftheoutersleeve,200mm(7.9in.)fromthe Removea40mm(1.6in.)sectionoftheoutersleeve,200mm(7.9in.)fromthe
ATMendofthecable. ATMendofthecable.
Takecarenottocutthroughthecableshielding. Takecarenottocutthroughthecableshielding.

40 mm
40 mm
(1.6 in.)
(1.6 in.)

200 mm
200 mm
(7.9 in.)
(7.9 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
CableRequirements 73
REMOTESTATUSMONITOR REMOTERELAYCABLE POWERCABLE
Theremotestatusmonitorfeatureissuppliedasacompleteassembly Theremoterelayprovidesapairofopencontacts,ratedat28voltsperampere TheATMissuppliedeitherasa120Vora220240Vunit.120VATMsare
consistingofastatusindicatorunit,76.2m(250ft)ofcableandaconnector. forbothacanddcsupplies,whichcanbeclosedtoactivatearemotedevice. suppliedwithapowercablefittedwithaNEMAtype515Ppowersource
Theinterconnectingcabletoaremotedevicemustconformtothefollowing connector.220240VATMsaresuppliedwithanunterminatedpowercable.
specificationandwiring: Informationaboutsuitablepowerconnectorsissuppliedwiththeaccessories.
1, 2 4 Thepowercablesuppliedis3m(9.84ft)inlength.Ifitisnecessarytoincrease
3
thislengthtomeetsiterequirements,thentheextensionmustsatisfylocalor
countryregulations.Powerconnectorsmustbewiredasshownbelow.

WARNING Thisequipmentmustbeearthed.
1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285).
2. Terminal wire, male (NCR part no. 007-2009663).
3. Cable, multiconductor (NCR part no. 006-5800006).
4. Connector (determined by remote device).
Removea40mm(1.6in.)sectionoftheoutersleeve,200mm(7.9in.)fromthe
ATMendofthecable.
1 RL 1
Takecarenottocutthroughthecableshielding. 2 RL 2

40 mm
(1.6 in.) Removea40mm(1.6in.)sectionoftheoutersleeve,200mm(7.9in.)fromthe
ATMendofthecable.
Takecarenottocutthroughthecableshielding.

40 mm
200 mm (1.6 in.)
(7.9 in.)

ShorteningtheCable
200 mm
Ifyouneedtoshortenthecable,proceedasfollows: (7.9 in.)

1. Removethecoverfromtheremotestatusindicatorunit
2. Disconnectthefourleads(E1,E2,E3andE4)fromtheindicator
Red
ETHERNETSTANDARDCABLE
Theethernetstandardcablemustbefullyshielded,8pin,category5compliant
Yellow andmustnotexceed97m(318.20ft)inlength.
Green Removea40mm(1.6in.)sectionoftheoutersleeve,1.8m(5.9ft.)fromthe
(Green) E1
ATMendofthecable.
(Red) E2 Takecarenottocutthroughthecableshielding.
(White) E3 40 mm
(1.6 in.)
(Black) E4

3. Cutthecabletotherequiredlengthandstripthefourwireends
4. Connectthewirestothecorrectterminals
1.8 m
5. Replacethestatusindicatorcover. (5.9 ft.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
Decals 81
CARDORIENTATIONWINDOW STANDARDCOLLARWITHADVERTLIGHT DECALPLACEMENT
Anindustrystandardcreditcardcanbeplacedbehindthecardorientation NCRrecommendsplacingentry/exitdecalsaboveorbelowtheentry/exitslots,
window. determinedbythespaceavailableneartheslot.
483 mm
Thecardordecalshouldbeamaximumof0.75mm(0.0295in.)thick. (19.02 in.) CardOrientationWindowdecal/cardareplacedontheinsideofthewindow.
Advertdecalscanbeplacedwithinarecessonthefasciaoroneitherthefront
ortheinsideofthecollaradvertwindow.

5 mm
168 mm
(0.20 in.)
(6.61 in.)
Radius

Collar Advert Window


85 mm
(3.34 in.)

2.5mm (0.10 in.)


Radius
Advert Recess

54 mm
(2.13 in.) ENTRY/EXITDECALS
Entry/Exitdecalsshouldbeamaximumof0.5mm(0.02in.)thick.NCR
recommendstheybemadefromtexturedpolycarbonatewith3M467High
Note: Notsuitableforusewiththecontactlesscardreader. PerformanceMPadhesive.
Decalsshouldprovidegoodcontrast,atleast70%,betweenforeground(text/
icon)andbackground.
ADVERTDECALRECESS
Asansseriftypefaceshouldbeused(Tiresiasisrecommended).Thetextsize
shouldbeatleast14point,andlargerwherepossible.Wheretactiledecalsare Receipt
Card Orientation
WithoutCameraLens requiredtheyshouldbedesignedinlinewithspecificcountryrequirements. Window

Suggestedicondesignsandwordingareshownbelow:

400 mm
(15.75 in.)
70 mm Cash Dispense
(2.76 in.)
38.5 mm
(1.51 in.)
12 mm
(0.47 in.)
9 mm (0.35 in.)
Radius

WithCameraLens

400 mm
(15.75 in.)

38.5 mm
(1.51 in.)

9 mm (0.35 in.)
Radius 38.7 mm (1.52 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,ShortSleeve 91
PACKAGEDIMENSIONS CENIIIandCENIVSecurityEnclosures AdvertCollar
548 mm 38 mm
(21.57 in.) (1.50 in.)
805 mm 742 mm
1420 mm (31.7 in.) (29.21 in.)
(55.9 in.)

258 mm 1109 mm
(10.16 in.) (43.66 in.)

23 mm 23 mm 1769 mm
(0.90 in.) 424 mm (0.90 in.) (69.65 in.)
(16.69 in.)
1827 mm 1143 mm
473 mm 225 mm
(71.9 in.) (45.00 in.)
(8.86 in.)
(18.62 in.) 803 mm
660 mm
(31.61 in.)
(25.98 in.)
1702 mm
(67.0 in.)

39 mm 39 mm
(1.54 in.) (1.54 in.)
1405 mm
801 mm (55.3 in.) 1498 mm
(31.5 in.) (58.98 in.) 258 mm
(10.16 in.)
845 mm
722 mm
(33.27 in.) WEIGHTANDFLOORLOADING
(28.43 in.)

260 mm 800 mm StandardSecurityEnclosures


ATMDIMENSIONS 470 mm (10.24 in.) (31.50 in.)
(18.50 in.) 883 mm CEN Grade L and CEN
(34.76 in.) CEN Grade III CEN Grade IV
Grade I
CENLandCENISecurityEnclosures
538 kg 664 kg 698 kg
Maximum weight
(1186.3 lb.) (1464.1 lb.) (1539.0 lb.)
1431 kg/m2 1766 kg/m2 1856 kg/m2
Floor loading
(293.0 lb./ft2) (361.7 lb./ft2) (380.2 lb./ft2)
742 mm COLLARDIMENSIONS
(29.21 in.)

GasResistantSecurityEnclosures
StandardCollar
258 mm
(10.16 in.)
548 mm 38 mm CEN Grade III CEN Grade IV
23 mm 23 mm (21.57 in.) (1.50 in.) 679 kg 724 kg
(0.90 in.) 424 mm (0.90 in.) Maximum weight
(1496.9 lb.) (1596.1 lb.)
(16.69 in.)
1123 mm 1806 kg/m2 1926 kg/m2
473 mm Floor loading
(44.21 in.) (369.8 lb./ft2) (394.3 lb./ft2)
(18.62 in.) 803 mm
(31.61 in.) 897 mm
(35.31 in.)

1557 mm
(61.30 in.)

225 mm
1498 mm (8.86 in.)
(58.98 in.) 258 mm 660 mm
(10.16 in.) (25.98 in.)
845 mm
722 mm
(33.27 in.)
(28.43 in.)

39 mm 39 mm
(1.54 in.) (1.54 in.)
260 mm 800 mm
470 mm (10.24 in.) (31.50 in.)
(18.50 in.) 863 mm
(33.98 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,ShortSleeve 92
SECURITYBOLTS BOLTHOLES CABLEENTRY
Boltsandanchorsmustbesuppliedbytheowningorganisation. TheATMshouldbeboltedtothefloororplinth,throughalltheholesmarked
A,usingfourboltswithanchorwashers.
TomeetsecuritystandardstheATMmustbeboltedtothefloor,throughallof 470 mm
theboltholes,usingboltswithanchorwashersasspecifiedbelow.Boltsand TheBholeenablesanalarmtobefittedonATMswithCENL,CENIandCENIII (18.50 in.)
anchorwashersaretobesuppliedbytheowningorganisation. securityenclosures.
Makesurethatthefloororplinthiscapableofwithstandingtheloading
imposedbytheanchorpointsforthesebolts.
470 mm
Ifanadjustableplinthisused,itmustbeboltedtothefloortothesame (18.50 in.)
specificationastheATM. 82 mm 265 mm 123 mm
(3.23 in.) (10.43 in.) (4.84 in.) 800 mm
TheminimumspecificationforboltsandwasherstosecuretheATMtoa 82 mm 323 mm 65 mm 33 mm
112 mm (31.50 in.) (3.23 in.) (12.72 in.) (2.55 in.) (1.30 in.)
concreteflooris: (4.41 in.)

Bolts
230 mm
Typeeitherresinanchororshieldanchorbolts (9.06 in.)
A B A 160 mm
SizeM16(5/8in.) 106 mm
(6.30 in.)
MinimumLength150mm(5.9in.) (4.17 in.)
800 mm 133 mm 271 mm
Strengthhightensile(minimumISOpropertyclass8,8). (5.24 in.) (10.67 in.)
(31.50 in.) 410 mm
Washers (16.14 in.)
Typeflat,steel(asperDIN7349orequivalent)
33 mm
A A
SizeM16(5/8in.) (1.30 in.)

Outerdiameternogreaterthan40mm(1.58in.) 160 mm CHAINGUARDHOLES


(6.30 in.)
Minimumthickness6mm(0.2in.). 391 mm CENGradeIIIsecurityenclosuresprovidechainguardholesatthelocations
(15.39 in.)
shownintheillustrationbelow.
Thethicknessofthesecurityenclosurewallmayvary,butwillnotbegreater
than45mm(1.77in.).
203 mm
(8.00 in.)
Maximum

A - Bolt Holes B - Alarm Hole (CEN L, CEN I and CEN III only)

45 mm 60 mm A
(1.8 in.) (2.4 in.)
20 mm 25 mm
(0.78 in.) 45 mm (0.98 in.) 45 mm 40 mm
(1.77 in.) (1.77 in.)
(1.57 in.)
28 mm 28 mm
(1.1 in.) (1.1 in.) 100 mm
A A (3.94 in.)

155 mm
324 mm 321 mm (6.10 in.)
(12.76 in.) (12.64 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,ShortSleeve 93
HOLEINTHEWALL HoleatLoweredHeight
Itistheresponsibilityoftheowninginstitutiontomakesurethattheheights
HoleatOptimumHeight fromthesidewalkleveltothefaciaitemscomplywithanylocalregulations.
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
Itistheresponsibilityoftheowninginstitutiontoensurethattheheightsfrom
betweenthesidewalkandtheinteriorfloor.Ifthereisnodifferencethenthe
thesidewalkleveltothefaciaitemscomplywithanylocalregulations.Where
nosuchregulationsexist,theATMcanbeinstalledattheNCRoptimumheight. plinthmusthaveoneoftheheightsspecifiedinthetablebelow.
NCRrecommendsinstallationthroughalargerholeinthewallforeasy
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
installation.
betweenthesidewalkandtheinteriorfloor.Ifthereisnodifferencethenthe
plinthmusthavetheheightspecifiedintheillustrationsbelow.
Installation Height
CAE CSA
ADA
Parallel Approach Parallel Approach
774 mm 744 mm 724 mm
443 mm A - Bottom of hole
(30.47 in.) (29.29 in.) (28.50 in.)
(17.44 in.)
62 mm 32 mm 12 mm
B - Plinth height
(2.44 in.) (1.26 in.) (0.47 in.)

793 mm Hole in
(31.22 in.) the Wall

443 mm
(17.44 in.)

924 mm 793 mm Hole in


(36.38 in.) (31.22 in.) the Wall
212 mm
(8.35 in.)
ATM Base

Plinth

Maximum 203 mm (8.0 in.) View From Inside Building

B
ATM Base
Plinth

Maximum 203 mm (8.0 in.) View From Inside Building

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,ShortSleeve 94
FACIAITEMS HeightsandDepths DistanceforVoiceGuidance

Height Depth
Facia Item from base from front
of ATM of collar
11 12 1 Distance from
Facia Item 10 2
1338 mm 222 mm 9 3 No. 5 Key
Barcode Reader
(52.68 in.) (8.74 in.) 8
7 6 5
4

Touchscreen 1269 mm 260 mm


Top
381 mm (15.0 in.) (49.96 in.) (10.24 in.)
156 mm
Card Reader 2
(6.14 in.)
Touchscreen 1245 mm 261 mm
Top
307 mm (12.1 in.) (49.02 in.) (10.28 in.)
150 mm
Conctactless Card Reader 3
(5.90 in.)
Display with FDK Top FDK 1188 mm 228 mm
381 mm (15.0 in.) Display (centre) (46.77 in.) (8.98 in.) 146 mm
Audio Jack Plug 4
(5.75 in.)
JKL
5 Display with FDK Top FDK 1177 mm 224 mm 140 mm
307 mm (12.1 in.) Display (centre) (46.3 in.) (8.82 in.) S Cash Exit 6
(5.51 in.)

1168 mm 118 mm 120 mm


Barcode Activation Point Receipt Exit 10
(45.98 in.) (4.65 in.) (4.72 in.)
S
965 mm 181 mm Display with FDKs Top Left 302 mm
2nd Card Reader 11
(38.0 in.) (7.1 in.) 307 mm (12.1 in.) Display FDK (11.89 in.)

960 mm 164 mm Display with FDKs Top Left 326 mm


TopmostViewableFaciaItem Card Reader 11
(37.8 in.) (6.46 in.) 381 mm (15.0 in.) Display FDK (12.83 in.)
Thetouchscreenisthehighestviewablefaciaitemwithaprojectionangle
953 mm 168 mm 242 mm
shownintheillustrationbelow. Receipt Barcode Activation Point 12
(37.5 in.) (6.61 in.) (9.53 in.)

Contactless Card Reader 912 mm 119 mm 64 mm


38
o
(on Facia with PIN Shield) (35.9 in.) (4.7 in.) 2nd Card Reader 12
(2.52 in.)

Contactless Card Reader 907 mm 119 mm


(on Facia without PIN Shield) (35.7 in.) (4.7 in.)

Contactless Card Reader 903 mm 141 mm


(behind Facia) (35.55 in.) (5.55 in.)

903 mm 141 mm
5
JKL
No. 5 Key
(35.55 in.) (5.55 in.)

864 mm 67 mm
Audio Jack Plug
(34.0 in.) (2.64 in.)

764 mm 65 mm
S Cash Exit
(30.1 in.) (2.56 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,ShortSleeve 95
SERVICINGAREASOPTIMUM SideBySide
TheoptimumservicingareaprovidesthebestaccesstotheATMforallservicingandoperationtasks.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea. 2440 mm
(96.1 in.)
IftheoptimumareaisnotavailablethenrefertoServicingAreasMinimum.HowevernotethatinstallingtheATMinthe
minimumservicingareamayincreasetheservicingand/orupgradingtimeoveraATMinstalledusingtheoptimumarea.
AlwaysleaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing.
Ifyouintendtofitachainguard,allowextraclearanceforfittingandremoval.

SingleATM 1500 mm
(59.1 in.)

1470 mm 2328 mm
(57.9 in.) (91.7 in.)

500 mm 500 mm 500 mm 828 mm


(19.7 in.) (19.7 in.) (19.7 in.) (32.6 in.)
1500 mm
(59.1 in.)

2328 mm
(91.7 in.)

203 mm
(8.0 in.)
750 mm
Maximum
(29.5 in.)
500 mm 500 mm 828 mm
(19.7 in.) (19.7 in.) (32.6 in.)

203 mm
(8.0 in.)
750 mm Maximum
(29.5 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,ShortSleeve 96
SERVICINGAREASMINIMUM SideBySide
ThisistheminimumarearequiredforoperatingandservicingtheATM.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea.InstallingtheATMintheminimum 2000 mm
servicingareamayincreasetheservicingand/orupgradingtime. (78.7 in.)

Iftheminimumareaisnotavailablethenconsultyourlocalservicerepresentative.Everysiteisdifferentandyoumaystill
beabletoinstalltheATMbutwithfurtherincreasestoservicingand/orupgradingtime.
Ifyouinstallintheminimumareathennotethatdoorscanopen,anddevicesrackout,beyondtheareashown.Always
900 mm
leaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing. (35.4 in.)
Ifyouintendtofitachainguard,allowextraclearanceforfittingandremoval.

SingleATM 1728 mm
(68.0 in.)

Thedispenserracksoutbeyondtheminimumrequiredclearancebyapproximately100mm(3.94in.) 380 mm 470 mm 380 mm 470 mm


(15.0 in.) (18.5 in.) (15.0 in.) (18.5 in.) 300 mm
(11.8 in.)
828 mm
(32.6 in.)
1150 mm 150 mm
(45.3 in.) (5.9 in.)

900 mm
(35.4 in.)
203 mm
(8.0 in.)
1728 mm 1931 mm Maximum
(68.0 in.) (76.0 in.)

380 mm
(15.0 in.) 470 mm 300 mm
(18.5 in.) (11.8 in.) 828 mm
(32.6 in.)
150 mm
(5.9 in.)

203 mm
(8.0 in.)
Maximum

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,ShortSleeve 97
CLEARANCESCORRIDOR CLEARANCESEXTERIORWALL INTERNALSPACECONSTRAINTFORTHIRDPARTYCAMERA
ThedimensionsshownassumetheATMisbeingmovedusingequipmentthat Ifathirdpartycameraistobeinstalled,itmustfitwithinthespaceconstraint
doesnotextendbeyondtheATMorpackaging. StandardCollar shownbelow.
Asurroundingclearanceof6mm(0.24in.)hasbeenallowedinthedimensions.
23 mm
(0.91 in.)

11 mm
10 mm 89 mm (0.43 in.)
(0.39 in.) (3.50 in.)
A B

30 mm
(1.18 in.) 66 mm 34 mm
(2.60 in.) (1.34 in.)
84 mm 116 mm
(3.31 in.) (4.57 in.)
B
168 mm
(6.61 in.)
45 mm
(1.77 in.)
124
34 mm 100 mm
(1.34 in.) (3.94 in.)

30 mm 30 mm
C (1.18 in.) (1.18 in.)

Unpackaged Unpackaged
Packaged ATM ATM
Packaged ATM
ATM (without collar) (without collar)
(pallet, carton
(pallet and CEN Grade L CEN Grade III AdvertCollar
and lid)
carton) and and
CEN Grade I CEN Grade IV
817 mm 813 mm 485 mm 485 mm
A Doorway or straight corridor
(32.17 in.) (32.01 in.) (19.10 in.) (19.10 in.)
1083 mm 1075 mm 744 mm 751 mm 10 mm
B Corridor with corner (0.39 in.)
(42.64 in.) (42.32 in.) (29.29 in.) (29.57 in.)
1644 mm 1629 mm 1231 mm 1249 mm
C Rotation about centre
(64.72 in.) (64.13 in.) (48.46 in.) (49.17 in.)

45 mm
(1.77 in.)

30 mm 30 mm
(1.18 in.) (1.18 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,StandardSleeve 101
PACKAGEDIMENSIONS CENIIIandCENIVSecurityEnclosures AdvertCollar
548 mm 38 mm
(21.57 in.) (1.50 in.)
805 mm 742 mm
1420 mm (31.7 in.) (29.21 in.)
(55.9 in.)

1109 mm
371 mm (43.66 in.)
(14.61 in.)

23 mm 23 mm 1769 mm
(0.90 in.) (0.90 in.) (69.65 in.)
424 mm
1827 mm (16.69 in.) 1257 mm
(71.9 in.) (49.49 in.)
473 mm 803 mm 339 mm
(31.61 in.) 660 mm (13.35 in.)
(18.62 in.) (25.98 in.)
1702 mm
(67.0 in.)

39 mm 39 mm
(1.54 in.) (1.54 in.)
1405 mm
801 mm (55.3 in.) 1498 mm
(31.5 in.) (58.98 in.) 372 mm
(14.65 in.)
845 mm
722 mm
(33.27 in.) WEIGHTANDFLOORLOADING
(28.43 in.)

StandardSecurityEnclosures
ATMDIMENSIONS 374 mm 800 mm
470 mm (14.72 in.) (31.50 in.)
(18.50 in.) 883 mm CEN Grade L and CEN
(34.76 in.)
CEN Grade III CEN Grade IV
Grade I
CENLandCENISecurityEnclosures
538 kg 664 kg 698 kg
Maximum weight
(1186.3 lb.) (1464.1 lb.) (1539.0 lb.)
1431 kg/m2 1766 kg/m2 1856 kg/m2
Floor loading
COLLARDIMENSIONS (293.0 lb./ft2) (361.7 lb./ft2) (380.2 lb./ft2)
742 mm
(29.21 in.)

StandardCollar GasResistantSecurityEnclosures
371 mm
(14.61 in.) 548 mm 38 mm CEN Grade III CEN Grade IV
(21.57 in.) (1.50 in.)
23 mm 23 mm 679 kg 724 kg
Maximum weight
(0.90 in.) 424 mm (0.90 in.) (1496.9 lb.) (1596.1 lb.)
(16.69 in.) 1237 mm 1806 kg/m2 1926 kg/m2
Floor loading
(48.7 in.)
(369.8 lb./ft2) (394.3 lb./ft2)
473 mm 803 mm 897 mm
(18.62 in.) (31.61 in.) (35.31 in.)

1557 mm
(61.30 in.)

1498 mm 339 mm
660 mm
(58.98 in.) 372 mm (13.35 in.)
(25.98 in.)
(14.65 in.)
845 mm
722 mm
(33.27 in.)
(28.43 in.)
39 mm 39 mm
(1.54 in.) (1.54 in.)
374 mm 800 mm
470 mm (14.72 in.) (31.50 in.)
(18.50 in.) 863 mm
(33.98 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,StandardSleeve 102
SECURITYBOLTS BOLTHOLES CABLEENTRY
Thefloororplinthmustbecapableofwithstandingtheloadingimposedbythe TheATMshouldbeboltedtothefloororplinth,throughalltheholesmarked
anchorpointsforthebolts.Boltsandanchorsmustbesuppliedbytheowning A,usingfourboltswithanchorwashers.
organisation. 470 mm
(18.50 in.)
TomeetsecuritystandardstheATMmustbeboltedtothefloor,throughallof
theboltholes,usingboltswithanchorwashersasspecifiedbelow.Boltsand 470 mm
(18.50 in.)
anchorwashersaretobesuppliedbytheowningorganisation.
82 mm 265 mm 123 mm
Makesurethattheflooriscapableofwithstandingtheloadingimposedbythe (3.23 in.) (10.43 in.) (4.84 in.)
anchorpointsforthesebolts. 112 mm
(4.41 in.)
Ifanadjustableplinthisused,itmustbeboltedtothefloortothesame 800 mm 82 mm 323 mm 65 mm 33 mm
specificationastheATM. 230 mm (31.50 in.) (3.23 in.) (12.72 in.) (2.55 in.) (1.30 in.)
(9.06 in.)
TheminimumspecificationforboltsandwasherstosecuretheATMtoa A B A
concreteflooris:
800 mm 133 mm 271 mm
Bolts (5.24 in.) (10.67 in.) 160 mm
(31.50 in.) 410 mm 106 mm
Typeeitherresinanchororshieldanchorbolts (6.30 in.)
(16.14 in.) (4.17 in.)
SizeM16(5/8in.)
33 mm
MinimumLength150mm(5.9in.) A A (1.30 in.)
Strengthhightensile(minimumISOpropertyclass8,8). 160 mm
(6.30 in.)
Washers
Typeflat,steel(asperDIN7349orequivalent)
505 mm
SizeM16(5/8in.) (19.88 in.) CHAINGUARDHOLES
Outerdiameternogreaterthan40mm(1.58in.) CENGradeIIIsecurityenclosuresprovidechainguardholesatthelocations
Minimumthickness6mm(0.2in.). shownintheillustrationbelow.
Thethicknessofthesecurityenclosurewallmayvary,butwillnotbegreater
330 mm than45mm(1.77in.).
(13.00 in.)
Maximum

A - Bolt Holes B - Alarm Hole (CEN L, CEN I and CEN III only)

45 mm 60 mm
(2.4 in.) A
(1.8 in.)
20 mm 25 mm
(0.78 in.) 45 mm (0.98 in.) 45 mm
(1.77 in.) (1.77 in.) 40 mm
(1.57 in.)
28 mm 28 mm
(1.1 in.) (1.1 in.)
100 mm
A A (3.94 in.)

155 mm
324 mm 321 mm (6.10 in.)
(12.76 in.) (12.64 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,StandardSleeve 103
HOLEINTHEWALL HoleatLoweredHeight
Itistheresponsibilityoftheowninginstitutiontomakesurethattheheights
HoleatOptimumHeight fromthesidewalkleveltothefaciaitemscomplywithanylocalregulations.
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
Itistheresponsibilityoftheowninginstitutiontoensurethattheheightsfrom
betweenthesidewalkandtheinteriorfloor.Ifthereisnodifferencethenthe
thesidewalkleveltothefaciaitemscomplywithanylocalregulations.Where
nosuchregulationsexist,theATMcanbeinstalledattheNCRoptimumheight. plinthmusthaveoneoftheheightsspecifiedinthetablebelow.
NCRrecommendsinstallationthroughalargerholeinthewallforeasy
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
installation.
betweenthesidewalkandtheinteriorfloor.Ifthereisnodifferencethenthe
plinthmusthavetheheightspecifiedintheillustrationsbelow.
Installation Height
CAE CSA
ADA
Parallel Approach Parallel Approach
774 mm 744 mm 724 mm
443 mm A - Bottom of hole
(30.47 in.) (29.29 in.) (28.50 in.)
(17.44 in.)
62 mm 32 mm 12 mm
B - Plinth height
(2.44 in.) (1.26 in.) (0.47 in.)

793 mm Hole in
(31.22 in.) the Wall

443 mm
(17.44 in.)

924 mm 793 mm Hole in


(36.38 in.) (31.22 in.) the Wall
212 mm
(8.35 in.)
ATM Base

Plinth

Maximum 330 mm (13.0 in.) View From Inside Building

B
ATM Base
Plinth

Maximum 330 mm (13.0 in.) View From Inside Building

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,StandardSleeve 104
FACIAITEMS HeightsandDepths DistanceforVoiceGuidance

Height Depth
Facia Item from base from front
of ATM of collar
11 12 1 Distance from
Facia Item 10 2
1338 mm 222 mm 9 3 No. 5 Key
Barcode Reader
(52.68 in.) (8.74 in.) 8
7 6 5
4

Touchscreen 1269 mm 260 mm


Top
381 mm (15.0 in.) (49.96 in.) (10.24 in.)
156 mm
Card Reader 2
(6.14 in.)
Touchscreen 1245 mm 261 mm
Top
307 mm (12.1 in.) (49.02 in.) (10.28 in.)
150 mm
Conctactless Card Reader 3
(5.90 in.)
Display with FDKs 1st FDK 1188 mm 228 mm
381 mm (15.0 in.) Display (centre) (46.77 in.) (8.98 in.) 146 mm
Audio Jack Plug 4
(5.75 in.)
JKL
5 Display with FDKs 1st FDK 1177 mm 224 mm 140 mm
307 mm (12.1 in.) Display (centre) (46.3 in.) (8.82 in.) S Cash Exit 6
(5.51 in.)

1168 mm 118 mm 120 mm


Barcode Activation Point Receipt Exit 10
(45.98 in.) (4.65 in.) (4.72 in.)
S
965 mm 181 mm Display with FDKs Top Left 302 mm
2nd Card Reader 11
(38.0 in.) (7.1 in.) 307 mm (12.1 in.) Display FDK (11.89 in.)

960 mm 164 mm Display with FDKs Top Left 326 mm


TopmostViewableFaciaItem Card Reader 11
(37.8 in.) (6.46 in.) 381 mm (15.0 in.) Display FDK (12.83 in.)
Thetouchscreenisthehighestviewablefaciaitemwithaprojectionangle
953 mm 168 mm 242 mm
shownintheillustrationbelow. Receipt Barcode Activation Point 12
(37.5 in.) (6.61 in.) (9.53 in.)

Contactless Card Reader 912 mm 119 mm 64 mm


(on Facia with PIN Shield) (35.9 in.) (4.7 in.) 2nd Card Reader 12
38
o
(2.52 in.)

Contactless Card Reader 907 mm 119 mm


(on Facia without PIN Shield) (35.7 in.) (4.7 in.)

Contactless Card Reader 903 mm 141 mm


(behind Facia) (35.55 in.) (5.55 in.)

903 mm 141 mm
5
JKL
No. 5 Key
(35.55 in.) (5.55 in.)

864 mm 67 mm
Audio Jack Plug
(34.0 in.) (2.64 in.)

764 mm 65 mm
S Cash Exit
(30.1 in.) (2.56 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,StandardSleeve 105
SERVICINGAREASOPTIMUM SideBySide
TheoptimumservicingareaprovidesthebestaccesstotheATMforallservicingandoperationtasks.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea. 2440 mm
(96.1 in.)
IftheoptimumareaisnotavailablethenrefertoServicingAreasMinimum.HowevernotethatinstallingtheATMinthe
minimumservicingareamayincreasetheservicingand/orupgradingtimeoveraATMinstalledusingtheoptimumarea.
AlwaysleaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing.
Ifyouintendtofitachainguard,allowextraclearanceforfittingandremoval.

SingleATM 1500 mm
(59.1 in.)

1470 mm 2315 mm
(57.9 in.) (91.1 in.)

500 mm 500 mm 500 mm 815 mm


(19.7 in.) (19.7 in.) (19.7 in.) (32.1 in.)
1500 mm
(59.1 in.)

2315 mm
(91.1 in.)

330 mm
(13.0 in.) 750 mm
Maximum (29.5 in.)
500 mm 500 mm 815 mm
(19.7 in.) (19.7 in.) (32.1 in.)

330 mm
750 mm (13.0 in.)
(29.5 in.) Maximum

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,StandardSleeve 106
SERVICINGAREASMINIMUM SideBySide
ThisistheminimumarearequiredforoperatingandservicingtheATM.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea.InstallingtheATMintheminimum 2000 mm
servicingareamayincreasetheservicingand/orupgradingtime. (78.7 in.)

Iftheminimumareaisnotavailablethenconsultyourlocalservicerepresentative.Everysiteisdifferentandyoumaystill
beabletoinstalltheATMbutwithfurtherincreasestoservicingand/orupgradingtime.
Ifyouinstallintheminimumareathennotethatdoorscanopen,anddevicesrackout,beyondtheareashown.Always
900 mm
leaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing. (35.4 in.)
Ifyouintendtofitachainguard,allowextraclearanceforfittingandremoval.

SingleATM 1715 mm
(67.5 in.)
Thedispenserracksoutbeyondtheminimumrequiredclearancebyapproximately100mm(3.94in.) 380 mm 470 mm 380 mm 470 mm
(15.0 in.) (18.5 in.) (15.0 in.) (18.5 in.) 300 mm
(11.8 in.)
815 mm
150 mm (32.1 in.)
1150 mm (5.9 in.)
(45.3 in.)

900 mm
(35.4 in.)
330 mm
(13.0 in.)
1715 mm 2045 mm Maximum
(67.5 in.) (80.5 in.)

380 mm
(15.0 in.) 470 mm 300 mm
(18.5 in.) (11.8 in.) 815 mm
(32.1 in.)
150 mm
(5.9 in.)

330 mm
(13.0 in.)
Maximum

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsCEN,StandardSleeve 107
CLEARANCESCORRIDOR CLEARANCESEXTERIORWALL INTERNALSPACECONSTRAINTFORTHIRDPARTYCAMERA
ThedimensionsshownassumetheATMisbeingmovedusingequipmentthat Ifathirdpartycameraistobeinstalled,itmustfitwithinthespaceconstraint
doesnotextendbeyondtheATMorpackaging. StandardCollar shownbelow.
Asurroundingclearanceof6mm(0.24in.)hasbeenallowedinthedimensions.
23 mm
(0.91 in.)

11 mm
10 mm 89 mm (0.43 in.)
(0.39 in.) (3.50 in.)
A B

30 mm
(1.18 in.) 66 mm 34 mm
(2.60 in.) (1.34 in.)
84 mm 230 mm
(3.31 in.) (9.06 in.)
B
168 mm
(6.61 in.)
45 mm
(1.77 in.)
124
34 mm 100 mm
(1.34 in.) (3.94 in.)
30 mm 30 mm
C (1.18 in.) (1.18 in.)

Unpackaged Unpackaged
Packaged ATM ATM
Packaged ATM
ATM (without collar) (without collar)
(pallet, carton
(pallet and CEN Grade L CEN Grade III AdvertCollar
and lid)
carton) and and
CEN Grade I CEN Grade IV
817 mm 813 mm 485 mm 485 mm
A Doorway or straight corridor
(32.17 in.) (32.01 in.) (19.10 in.) (19.10 in.)
1083 mm 1075 mm 784 mm 791 mm 10 mm
B Corridor with corner (0.39 in.)
(42.64 in.) (42.32 in.) (30.87 in.) (31.14 in.)
1644 mm 1629 mm 1336 mm 1355 mm
C Rotation about centre
(64.72 in.) (64.13 in.) (52.60 in.) (53.35 in.)

45 mm
(1.77 in.)

30 mm 30 mm
(1.18 in.) (1.18 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,ShortSleeve 111
PACKAGEDIMENSIONS COLLARDIMENSIONS WEIGHTANDFLOORLOADING
UL 291 Level 1
StandardCollar
805 mm 510 kg
Maximum weight
1420 mm (31.7 in.) (1124.6 lb.)
(55.9 in.) 1356 kg/m2
Floor loading
548 mm 38 mm (277.8 lb./ft2)
(21.57 in.) (1.50 in.)

1827 mm 897 mm
(71.9 in.) (35.31 in.)

1548 mm
1693 mm (60.94 in.)
(66.65 in.)
225 mm
(8.86 in.)
651 mm
1405 mm (25.63 in.)
801 mm (55.3 in.)
(31.5 in.)

39 mm 39 mm
(1.54 in.) (1.54 in.)

ATMDIMENSIONS AdvertCollar

548 mm 38 mm
(21.57 in.) (1.50 in.)

742 mm
(29.21 in.)

258 mm 1109 mm
(10.16 in.) (43.66 in.)
23 mm 23 mm
(0.90 in.) (0.90 in.) 1760 mm
424 mm (69.29 in.)
(16.69 in.)
1097 mm
473 mm 225 mm
(43.19 in.)
(18.62 in.) (8.86 in.)
803 mm 651 mm
(31.61 in.) (25.63 in.)

39 mm 39 mm
(1.54 in.) (1.54 in.)

1489 mm
(58.62 in.) 258 mm
(10.16 in.)
836 mm
713 mm
(32.91 in.)
(28.07 in.)

260 mm 800 mm
470 mm (10.24 in.) (31.50 in.)
(18.50 in.) 837 mm
(32.95 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,ShortSleeve 112
SECURITYBOLTS BOLTHOLES CABLEENTRY
Thefloororplinthmustbecapableofwithstandingtheloadingimposedbythe TheATMshouldbeboltedtothefloororplinth,throughalltheholesmarked
anchorpointsforthebolts.Boltsandanchorsmustbesuppliedbytheowning A,usingfourboltswithanchorwashers.
organisation. 470 mm
(18.50 in.)
TomeetsecuritystandardstheATMmustbeboltedtothefloor,throughallof
theboltholes,usingboltswithanchorwashersasspecifiedbelow.Boltsand
470 mm
anchorwashersaretobesuppliedbytheowningorganisation. (18.50 in.)
Makesurethattheflooriscapableofwithstandingtheloadingimposedbythe 60 mm 270 mm 140 mm
anchorpointsforthesebolts. (2.36 in.) (10.63 in.) (5.51 in.)
800 mm 33 mm
Ifanadjustableplinthisused,itmustbeboltedtothefloortothesame 43 mm (1.30 in.)
(31.50 in.) (1.69 in.)
specificationastheATM. 254 mm
135 mm
(5.31 in.) (10.00 in.)
TheminimumspecificationforboltsandwasherstosecuretheATMtoa
A A
concreteflooris: 148 mm
(5.83 in.)
Bolts 800 mm 247 mm 118 mm
(31.50 in.) (9.72 in.)
Typeeitherresinanchororshieldanchorbolts (4.65 in.)
428 mm
SizeM16(5/8in.) (16.85 in.)
175 mm 33 mm 60 mm 374.5 mm 35.5 mm
MinimumLength150mm(5.9in.) (2.36 in.) (14.74 in.) (1.40 in.)
(6.89 in.) (1.30 in.)
Strengthhightensile(minimumISOpropertyclass8,8). A A
Washers 118 mm
(4.65 in.)
Typeflat,steel(asperDIN7349orequivalent)
349 mm
SizeM16(5/8in.) (13.74 in.)
Outerdiameternogreaterthan40mm(1.58in.)

Minimumthickness6mm(0.2in.).

203 mm
(8.00 in.)
Maximum

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,ShortSleeve 113
HOLEINTHEWALL HoleatLoweredHeight
Itistheresponsibilityoftheowninginstitutiontomakesurethattheheights
HoleatOptimumHeight fromthesidewalkleveltothefaciaitemscomplywithanylocalregulations.
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
Itistheresponsibilityoftheowninginstitutiontoensurethattheheightsfrom
betweenthesidewalkandtheinteriorfloor.Ifthereisnodifferencethenthe
thesidewalkleveltothefaciaitemscomplywithanylocalregulations.Where
nosuchregulationsexist,theATMcanbeinstalledattheNCRoptimumheight. plinthmusthaveoneoftheheightsspecifiedinthetablebelow.
NCRrecommendsinstallationthroughalargerholeinthewallforeasy
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
installation.
betweenthesidewalkandtheinteriorfloor.Ifthereisnodifferencethenthe
plinthmusthavetheheightspecifiedintheillustrationsbelow.
Installation Height
CAE CSA
ADA
Parallel Approach Parallel Approach
774 mm 744 mm 724 mm
443 mm A - Bottom of hole
(30.47 in.) (29.29 in.) (28.50 in.)
(17.44 in.)
71 mm 41 mm 21 mm
B - Plinth height
(2.80 in.) (1.61 in.) (0.83 in.)

793 mm Hole in
(31.22 in.) the Wall

443 mm
(17.44 in.)

924 mm 793 mm Hole in


(36.38 in.) (31.22 in.) the Wall
221 mm
(8.70 in.)
ATM Base

Plinth

Maximum 203 mm (8.0 in.) View From Inside Building

B
ATM Base
Plinth

Maximum 203 mm (8.0 in.) View From Inside Building

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,ShortSleeve 114
FACIAITEMS HeightsandDepths DistanceforVoiceGuidance

Height Depth
Facia Item from base from front
of ATM of collar
11 12 1 Distance from
Facia Item 10 2
1329 mm 222 mm 9 3 No. 5 Key
Barcode Reader
(52.32 in.) (8.74 in.) 8
7 6 5
4

Touchscreen 1260 mm 260 mm


Top
381 mm (15.0 in.) (49.61 in.) (10.24 in.)
156 mm
Card Reader 2
(6.14 in.)
Touchscreen 1236 mm 261 mm
Top
307 mm (12.1 in.) (48.66 in.) (10.28 in.)
150 mm
Conctactless Card Reader 3
(5.90 in.)
Display with FDKs 1st FDK 1179 mm 228 mm
381 mm (15.0 in.) Display (centre) (46.42 in.) (8.98 in.) 146 mm
Audio Jack Plug 4
(5.75 in.)
JKL
5 Display with FDKs 1st FDK 1168 mm 224 mm 140 mm
307 mm (12.1 in.) Display (centre) (46.0 in.) (8.82 in.) S Cash Exit 6
(5.51 in.)

1159 mm 118 mm 120 mm


Barcode Activation Point Receipt Exit 10
(45.63 in.) (4.65 in.) (4.72 in.)
S
956 mm 181 mm Display with FDKs Top Left 302 mm
2nd Card Reader 11
(37.6 in.) (7.1 in.) 307 mm (12.1 in.) Display FDK (11.89 in.)

951 mm 164 mm Display with FDKs Top Left 326 mm


TopmostViewableFaciaItem Card Reader 11
(37.4 in.) (6.46 in.) 381 mm (15.0 in.) Display FDK (12.83 in.)
Thetouchscreenisthehighestviewablefaciaitemwithaprojectionangle
944 mm 168 mm 242 mm
shownintheillustrationbelow. Receipt Barcode Activation Point 12
(37.2 in.) (6.61 in.) (9.53 in.)

Contactless Card Reader 903 mm 119 mm 64 mm


(on Facia with PIN Shield) (35.6 in.) (4.7 in.) 2nd Card Reader 12
(2.52 in.)
o
38
Contactless Card Reader 898 mm 119 mm
(on Facia without PIN Shield) (35.4 in.) (4.7 in.)

Contactless Card Reader 894 mm 141 mm


(behind Facia) (35.2 in.) (5.55 in.)

894 mm 141 mm
5
JKL
No. 5 Key
(35.2 in.) (5.55 in.)

855 mm 67 mm
Audio Jack Plug
(33.7 in.) (2.64 in.)

755 mm 65 mm
S Cash Exit
(29.7 in.) (2.56 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,ShortSleeve 115
SERVICINGAREASOPTIMUM SideBySide
TheoptimumservicingareaprovidesthebestaccesstotheATMforallservicingandoperationtasks.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea. 2440 mm
(96.1 in.)
IftheoptimumareaisnotavailablethenrefertoServicingAreasMinimum.HowevernotethatinstallingtheATMinthe
minimumservicingareamayincreasetheservicingand/orupgradingtimeoveraATMinstalledusingtheoptimumarea.
AlwaysleaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing.
Ifyouintendtofitachainguard,allowextraclearanceforfittingandremoval.

SingleATM 1500 mm
(59.1 in.)

1470 mm 2328 mm
(57.9 in.) (91.7 in.)

500 mm 500 mm 500 mm 828 mm


(19.7 in.) (19.7 in.) (19.7 in.) (32.6 in.)
1500 mm
(59.1 in.)

2328 mm
(91.7 in.)

203 mm
(8.0 in.) 750 mm
Maximum (29.5 in.)
500 mm 500 mm 828 mm
(19.7 in.) (19.7 in.) (32.6 in.)

203 mm
(8.0 in.)
750 mm Maximum
(29.5 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,ShortSleeve 116
SERVICINGAREASMINIMUM SideBySide
ThisistheminimumarearequiredforoperatingandservicingtheATM.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea.InstallingtheATMintheminimum
2000 mm
servicingareamayincreasetheservicingand/orupgradingtime. (78.7 in.)

Iftheminimumareaisnotavailablethenconsultyourlocalservicerepresentative.Everysiteisdifferentandyoumaystill
beabletoinstalltheATMbutwithfurtherincreasestoservicingand/orupgradingtime.
Ifyouinstallintheminimumareathennotethatdoorscanopen,anddevicesrackout,beyondtheareashown.Always
leaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing. 900 mm
(35.4 in.)
Ifyouintendtofitachainguard,allowextraclearanceforfittingandremoval.

SingleATM 1728 mm
(68.0 in.)
Thedispenserracksoutbeyondtheminimumrequiredclearancebyapproximately100mm(3.94in.) 380 mm 470 mm 380 mm 470 mm
(15.0 in.) (18.5 in.) (15.0 in.) (18.5 in.) 300 mm
(11.8 in.)
828 mm
(32.6 in.)
1150 mm 150 mm
(45.3 in.) (5.9 in.)

900 mm
(35.4 in.)
203 mm
(8.0 in.)
1728 mm 1931 mm Maximum
(68.0 in.) (76.0 in.)

380 mm
(15.0 in.) 470 mm 300 mm
(18.5 in.) (11.8 in.) 828 mm
(32.6 in.)
150 mm
(5.9 in.)

203 mm
(8.0 in.)
Maximum

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,ShortSleeve 117
CLEARANCESCORRIDOR CLEARANCESEXTERIORWALL INTERNALSPACECONSTRAINTFORTHIRDPARTYCAMERA
ThedimensionsshownassumetheATMisbeingmovedusingequipmentthat Ifathirdpartycameraistobeinstalled,itmustfitwithinthespaceconstraint
doesnotextendbeyondtheATMorpackaging. StandardCollar shownbelow.
Asurroundingclearanceof6mm(0.24in.)hasbeenallowedinthedimensions.
23 mm
(0.91 in.)

11 mm
10 mm 89 mm (0.43 in.)
(0.39 in.) (3.50 in.)
A B

30 mm
(1.18 in.) 66 mm 34 mm
(2.60 in.) (1.34 in.)
84 mm 116 mm
(3.31 in.) (4.57 in.)
B
168 mm
(6.61 in.)
45 mm
(1.77 in.)
124
34 mm 100 mm
(1.34 in.) (3.94 in.)
30 mm 30 mm
C (1.18 in.) (1.18 in.)

Packaged ATM Packaged ATM


Unpackaged ATM
(pallet, carton (pallet and
(without collar)
and lid) carton)
817 mm 813 mm 485 mm AdvertCollar
A Doorway or straight corridor
(32.17 in.) (32.01 in.) (19.10 in.)
1083 mm 1075 mm 734 mm
B Corridor with corner
(42.64 in.) (42.32 in.) (28.90 in.)
1644 mm 1629 mm 1207 mm
C Rotation about centre 10 mm
(64.72 in.) (64.13 in.) (47.52 in.)
(0.39 in.)

45 mm
(1.77 in.)

30 mm 30 mm
(1.18 in.) (1.18 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,StandardSleeve 121
PACKAGEDIMENSIONS COLLARDIMENSIONS WEIGHTANDFLOORLOADING
UL 291 Level 1
StandardCollar
805 mm 510 kg
Maximum weight
1420 mm (31.7 in.) (1124.6 lb.)
548 mm 38 mm
(55.9 in.)
(21.57 in.) (1.50 in.) 1356 kg/m2
Floor loading
(277.8 lb./ft2)

897 mm
(35.31 in.)
1827 mm
(71.9 in.) 1548 mm
(60.94 in.)

1693 mm
(66.65 in.) 339 mm
651 mm
(13..35 in.)
(25.63 in.)

1405 mm
801 mm (55.3 in.)
(31.5 in.) 39 mm 39 mm
(1.54 in.) (1.54 in.)

AdvertCollar
ATMDIMENSIONS
548 mm 38 mm
(21.57 in.) (1.50 in.)

742 mm 1109 mm
(29.21 in.) (43.66 in.)

1760 mm
(69.29 in.)
371 mm
(14.61 in.)
23 mm 23 mm
(0.90 in.) 424 mm (0.90 in.) 651 mm 339 mm
(16.69 in.) (25.63 in.) (13.35 in.)
1211 mm
(47.68 in.)
473 mm 803 mm
(18.62 in.) (31.61 in.) 39 mm 39 mm
(1.54 in.) (1.54 in.)

1489 mm
(58.62 in.) 372 mm
(14.65 in.)
836 mm
713 mm
(32.91 in.)
(28.07 in.)

374 mm 800 mm
470 mm (14.72 in.) (31.50 in.)
(18.50 in.)
837 mm
(32.95 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,StandardSleeve 122
SECURITYBOLTS BOLTHOLES CABLEENTRY
Thefloororplinthmustbecapableofwithstandingtheloadingimposedbythe TheATMshouldbeboltedtothefloororplinth,throughalltheholesmarked
anchorpointsforthebolts.Boltsandanchorsmustbesuppliedbytheowning A,usingfourboltswithanchorwashers.
organisation. 470 mm
(18.50 in.)
TomeetsecuritystandardstheATMmustbeboltedtothefloor,throughallof
theboltholes,usingboltswithanchorwashersasspecifiedbelow.Boltsand 470 mm
(18.50 in.)
anchorwashersaretobesuppliedbytheowningorganisation.
60 mm 270 mm 140 mm
Makesurethattheflooriscapableofwithstandingtheloadingimposedbythe (2.36 in.) (10.63 in.) (5.51 in.)
anchorpointsforthesebolts.
800 mm 33 mm
Ifanadjustableplinthisused,itmustbeboltedtothefloortothesame 43 mm (1.30 in.)
135 mm 254 mm (31.50 in.) (1.69 in.)
specificationastheATM. (5.31 in.) (10.00 in.)

TheminimumspecificationforboltsandwasherstosecuretheATMtoa A A 247 mm
concreteflooris: (9.72 in.) 148 mm
800 mm 247 mm (5.83 in.)
Bolts (31.50 in.) (9.72 in.)
33 mm 428 mm 118 mm
Typeeitherresinanchororshieldanchorbolts (1.30 in.) (4.65 in.)
(16.85 in.)
SizeM16(5/8in.) 175 mm 33 mm
(6.89 in.) (1.30 in.) 60 mm 374.5 mm 35.5 mm
MinimumLength150mm(5.9in.)
A A (2.36 in.) (14.74 in.) (1.40 in.)
Strengthhightensile(minimumISOpropertyclass8,8). 118 mm
Washers (4.65 in.)

Typeflat,steel(asperDIN7349orequivalent)
463 mm
SizeM16(5/8in.) (18.23 in.)
Outerdiameternogreaterthan40mm(1.58in.)

Minimumthickness6mm(0.2in.).

330 mm
(13.00 in.)
Maximum

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,StandardSleeve 123
HOLEINTHEWALL HoleatLoweredHeight
Itistheresponsibilityoftheowninginstitutiontomakesurethattheheights
HoleatOptimumHeight fromthesidewalkleveltothefaciaitemscomplywithanylocalregulations.
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
Itistheresponsibilityoftheowninginstitutiontoensurethattheheightsfrom
betweenthesidewalkandtheinteriorfloor.Ifthereisnodifferencethenthe
thesidewalkleveltothefaciaitemscomplywithanylocalregulations.Where
nosuchregulationsexist,theATMcanbeinstalledattheNCRoptimumheight. plinthmusthaveoneoftheheightsspecifiedinthetablebelow.
NCRrecommendsinstallationthroughalargerholeinthewallforeasy
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
installation.
betweenthesidewalkandtheinteriorfloor.Ifthereisnodifferencethenthe
plinthmusthavetheheightspecifiedintheillustrationsbelow.
Installation Height
NCRrecommendsinstallationthroughalargerholeinthewallforeasy
CAE CSA
installation. ADA
Parallel Approach Parallel Approach
774 mm 744 mm 724 mm
A - Bottom of hole
(30.47 in.) (29.29 in.) (28.50 in.)
71 mm 41 mm 21 mm
B - Plinth height
(2.80 in.) (1.61 in.) (0.83 in.)
443 mm
(17.44 in.)

793 mm Hole in 443 mm


(31.22 in.) the Wall (17.44 in.)

793 mm Hole in
(31.22 in.) the Wall

924 mm
(36.38 in.) 221 mm
(8.70 in.)
ATM Base

Plinth
A
Maximum 330 mm (13.0 in.) View From Inside Building
B
ATM Base
Plinth

Maximum 330 mm (13.0 in.) View From Inside Building

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,StandardSleeve 124
FACIAITEMS HeightsandDepths DistanceforVoiceGuidance

Height Depth
Facia Item from base from front
of ATM of collar
11 12 1 Distance from
Facia Item 10 2
1329 mm 222 mm 9 3 No. 5 Key
Barcode Reader
(52.32 in.) (8.74 in.) 8
7 6 5
4

Touchscreen 1260 mm 260 mm


Top
381 mm (15.0 in.) (49.61 in.) (10.24 in.)
156 mm
Card Reader 2
(6.14 in.)
Touchscreen 1236 mm 261 mm
Top
307 mm (12.1 in.) (48.66 in.) (10.28 in.)
150 mm
Conctactless Card Reader 3
(5.90 in.)
Display with FDKs 1st FDK 1179 mm 228 mm
381 mm (15.0 in.) Display (centre) (46.42 in.) (8.98 in.) 146 mm
Audio Jack Plug 4
(5.75 in.)
JKL
5 Display with FDKs 1st FDK 1168 mm 224 mm 140 mm
307 mm (12.1 in.) Display (centre) (46.0 in.) (8.82 in.) S Cash Exit 6
(5.51 in.)

1159 mm 118 mm 120 mm


Barcode Activation Point Receipt Exit 10
(45.63 in.) (4.65 in.) (4.72 in.)
S
956 mm 181 mm Display with FDKs Top Left 302 mm
2nd Card Reader 11
(37.6 in.) (7.1 in.) 307 mm (12.1 in.) Display FDK (11.89 in.)

951 mm 164 mm Display with FDKs Top Left 326 mm


TopmostViewableFaciaItem Card Reader 11
(37.4 in.) (6.46 in.) 381 mm (15.0 in.) Display FDK (12.83 in.)
Thetouchscreenisthehighestviewablefaciaitemwithaprojectionangle
944 mm 168 mm 242 mm
shownintheillustrationbelow. Receipt Barcode Activation Point 12
(37.2 in.) (6.61 in.) (9.53 in.)

Contactless Card Reader 903 mm 119 mm 64 mm


(on Facia with PIN Shield) (35.6 in.) (4.7 in.) 2nd Card Reader 12
(2.52 in.)

38
o Contactless Card Reader 898 mm 119 mm
(on Facia without PIN Shield) (35.4 in.) (4.7 in.)

Contactless Card Reader 894 mm 141 mm


(behind Facia) (35.2 in.) (5.55 in.)

894 mm 141 mm
5
JKL
No. 5 Key
(35.2 in.) (5.55 in.)

855 mm 67 mm
Audio Jack Plug
(33.7 in.) (2.64 in.)

755 mm 65 mm
S Cash Exit
(29.7 in.) (2.56 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,StandardSleeve 125
SERVICINGAREASOPTIMUM SideBySide
TheoptimumservicingareaprovidesthebestaccesstotheATMforallservicingandoperationtasks.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea. 2440 mm
(96.1 in.)
IftheoptimumareaisnotavailablethenrefertoServicingAreasMinimum.HowevernotethatinstallingtheATMinthe
minimumservicingareamayincreasetheservicingand/orupgradingtimeoveraATMinstalledusingtheoptimumarea.
AlwaysleaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing.
Ifyouintendtofitachainguard,allowextraclearanceforfittingandremoval.

SingleATM 1500 mm
(59.1 in.)

1470 mm 2315 mm
(57.9 in.) (91.1 in.)

500 mm 500 mm 500 mm 815 mm


(19.7 in.) (19.7 in.) (19.7 in.) (32.1 in.)
1500 mm
(59.1 in.)

2315 mm
(91.1 in.)

330 mm
(13.0 in.)# 750 mm
Maximum (29.5 in.)
500 mm 500 mm 815 mm
(19.7 in.) (19.7 in.) (32.1 in.)

330 mm
750 mm (13.0 in.)
(29.5 in.) Maximum

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,StandardSleeve 126
SERVICINGAREASMINIMUM SideBySide
ThisistheminimumarearequiredforoperatingandservicingtheATM.
WhereverpossibletheATMshouldbeinstalledwithintheoptimumservicingarea.InstallingtheATMintheminimum
2000 mm
servicingareamayincreasetheservicingand/orupgradingtime. (78.7 in.)

Iftheminimumareaisnotavailablethenconsultyourlocalservicerepresentative.Everysiteisdifferentandyoumaystill
beabletoinstalltheATMbutwithfurtherincreasestoservicingand/orupgradingtime.
Ifyouinstallintheminimumareathennotethatdoorscanopen,anddevicesrackout,beyondtheareashown.Always
leaveasmuchspaceaspossiblearoundtheATMtofacilitatesafeoperationandservicing. 900 mm
(35.4 in.)
Ifyouintendtofitachainguard,allowextraclearanceforfittingandremoval.

SingleATM 1715 mm
(67.5 in.)
Thedispenserracksoutbeyondtheminimumrequiredclearancebyapproximately100mm(3.94in.) 380 mm 470 mm 380 mm 470 mm
(15.0 in.) (18.5 in.) (15.0 in.) (18.5 in.) 300 mm
(11.8 in.)
815 mm
150 mm (32.1 in.)
1150 mm
(5.9 in.)
(45.3 in.)

900 mm
(35.4 in.)

330 mm
1715 mm 2045 mm (13.0 in.)
(67.5 in.) (80.5 in.) Maximum

380 mm
(15.0 in.) 470 mm 300 mm
(18.5 in.) (11.8 in.) 815 mm
(32.1 in.)
150 mm
(5.9 in.)

330 mm
(13.0 in.)
Maximum

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000
NCRSelfServ26ATMSitePreparation
VariantDetailsUL,StandardSleeve 127
CLEARANCESCORRIDOR CLEARANCESEXTERIORWALL INTERNALSPACECONSTRAINTFORTHIRDPARTYCAMERA
ThedimensionsshownassumetheATMisbeingmovedusingequipmentthat Ifathirdpartycameraistobeinstalled,itmustfitwithinthespaceconstraint
doesnotextendbeyondtheATMorpackaging. StandardCollar shownbelow.
Asurroundingclearanceof6mm(0.24in.)hasbeenallowedinthedimensions.
23 mm
(0.91 in.)

11 mm
10 mm 89 mm (0.43 in.)
(0.39 in.) (3.50 in.)
A B

30 mm
(1.18 in.) 66 mm 34 mm
(2.60 in.) (1.34 in.)
84 mm 230 mm
(3.31 in.) (9.06 in.)
B
168 mm
(6.61 in.)
45 mm
(1.77 in.)
124
34 mm 100 mm
(1.34 in.) (3.94 in.)
30 mm 30 mm
C (1.18 in.) (1.18 in.)

Packaged ATM Packaged ATM


Unpackaged ATM
(pallet, carton (pallet and
(without collar)
and lid) carton)
817 mm 813 mm 485 mm AdvertCollar
A Doorway or straight corridor
(32.17 in.) (32.01 in.) (19.10 in.)
1083 mm 1075 mm 775 mm
B Corridor with corner
(42.64 in.) (42.32 in.) (30.51 in.)
1644 mm 1629 mm 1312 mm
C Rotation about centre 10 mm
(64.72 in.) (64.13 in.) (51.65 in.)
(0.39 in.)

45 mm
(1.77 in.)

30 mm 30 mm
(1.18 in.) (1.18 in.)

NCRProprietaryInformationnottobedisclosedorreproducedwithoutwrittenconsent.2008,2009,2010,2011,2012,2013byNCRCorporation,Duluth,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved B0066641H000