NAME OF PRODUCT Multislice CT Scan 16 Slice

BRAND / MANUFACTURER GE
MODEL / TYPE Brivo CT385
FACTORY OF ORIGIN China
REFERENCE OF TECHNICAL
TYPE
Number of slices acquired simultaneously 16
DETECTOR
Total detector width, z-axis, mm 20 mm
Optional minimum slice width, mm 0.625 mm
ADVANCED IMAGE ACQUISITION
Perfusion imaging Yes, Multi Organ CT Perfusion
GANTRY
Gantry tilt, Digital tilt 30
Gantry dimensions, H x W x D, cm 174.1 x 178.3 x 92.1 cm
Gantry weight, kg 980 kg
X-RAY TUBE
Max mA for smallest tube spot 200 mA
X-RAY GENERATOR
kW output 40 kW equivalent with ASiR
kVp range 80, 100, 120, 140 kV
mA range 10-200 mA
PATIENT TABLE
Range of movement
Vertical, cm 44.1 cm to 90 cm
Scannable range, cm Up to 135 cm
Max load capacity without restrictions, kg (accuracy, mm) 180 kg
RADIATION DOSE
Dose-modulation technique Auto mA
Pediatric-specific dose control Color Coding for Kids
Iterative image reconstruction ASiR Raw data based Iterative Reconstruction
Sliding collimation (overbeaming reduction) Beam Tracking Techniques
Superficial organ dose reduction Organ Dose Modulation
CLINICAL APPLICATIONS AND FUNCTIONALITY
Auto vessel mapping Yes, Advanced Vessel Analysis
Quantification Volume Viewer
Lung nodule assisted reading Lung VCAR (Optional in Workstation)
Lung nodule CAD Lung VCAR (Optional in Workstation)
Lung function analysis Lung VCAR (Optional in Workstation)
Virtual colonoscopy assisted reading Yes, CT Colonography
Virtual colonoscopy CAD Yes, CT Colonography
Vessel analysis (noncardiac) Yes, Advanced Vessel Analysis
Brain perfusion CT Perfusion Multi Organ
Z-axis coverage for brain perfusion 2 cm
Auto bone removal Yes, Autobone Xpress
Body perfusion CT Perfusion Multi Organ
Other CT Dental
IMAGE RECONSTRUCTION
Computer CPU Dual Intel Xeon Quad-Core 1.80GHz
Reconstruction matrices 512 x 512
Max reconstruction rate, (512 x 512), in/sec Up to 22 images/sec
Archival storage DVD-R / CD-R:
Image sharing DICOM 3.0
SYSTEM INTEGRATION
DICOM
CT image storage SCU/SCP Yes
Enhanced CT storage SCU/SCP Yes
Query/retrieve SCU and SCP Yes
Storage commitment SCU Yes
Modality performed procedure step SCU Yes
IMAGE PROCESSING
Standard or optional Standard
DICOM 3-D image export Yes
RECOMMENDED ROOM SIZE, m
Minimum W x L, m According to BAPETEN regulation
POWER REQUIREMENTS 40 kVA
SHIELDING REQUIREMENTS Required Pb according BAPETEN regulation.
Shielding not included
PURCHASE INFORMATION
System warranty 1 year warranty
X-ray tube warranty 1 year warranty
Training with purchase 2 times onsite training
Remote diagnostics Available (Optional)
Cooling requirements (including tube) In Room Air cooling only
GREEN FEATURES ENERGY SAVING MODE
with scheduled ES and Wake-Up Time

Das könnte Ihnen auch gefallen