Sie sind auf Seite 1von 111

Nokia Siemens Networks

GSM/EDGE BSS, rel.


RG10(BSS), operating
documentation, issue 06

Connector Panels and External Cables in


Flexi BSC and TCSM3i
DN70617303

Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2010. All rights reserved

f Important Notice on Product Safety


Elevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.

The same text in German:


Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Span-
nung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverlet-
zungen und Sachschden fhren.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.

2 Id:0900d805804bce7d DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i

Table of Contents
This document has 111 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1 Overview . . . . . . . . . . . . . . . . . . . . . ...... ....... ...... ....... . 10


1.1 Use of product names . . . . . . . . . . . ...... ....... ...... ....... . 10
1.2 Connector panels. . . . . . . . . . . . . . . ...... ....... ...... ....... . 10
1.3 Related information . . . . . . . . . . . . . ...... ....... ...... ....... . 11
1.4 Feedback . . . . . . . . . . . . . . . . . . . . . ...... ....... ...... ....... . 11

2 Connector panel types in the Flexi BSC . . . . . . . . . . . . . . . . . . . . . . . . 12

3 E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H) . . . 14


3.1 Connector panels CPETS-G and CPETS-H with RJ45 connectors. . . . 14
3.2 Flexi BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
3.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 34
3.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 39

4 E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F) . 40


4.1 Connector panels CPETS-E and CPETS-F with RJ45 connectors . . . . 40
4.2 Flexi BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
4.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 60
4.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 65

5 E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F). . 66


5.1 Connector panels CPETC-E and CPETC-F with D37 connector packs 66
5.2 Flexi BSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
5.2.1 Optional cabling cabinet is not used . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
5.2.2 Optional cabling cabinet is used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
5.3 TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
5.3.1 TCSM3i for stand-alone installation option . . . . . . . . . . . . . . . . . . . . . . 84
5.3.2 TCSM3i for combined BSC/TCSM installation option . . . . . . . . . . . . . . 90

6 Roof panel with LAN, LPT/VDU, and synchronisation and alarm interfaces
(CPRJ45-A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
6.1 LAN interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
6.1.1 1 Gbit/s optical uplink LAN cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
6.1.2 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cables . . . . . . . . . . . . . . . . 92
6.2 External alarm cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
6.3 VDU/LPT peripheral cabling (LPT/VDU interfaces) . . . . . . . . . . . . . . . 101
6.4 External synchronisation cabling (EXT SYNC interfaces) . . . . . . . . . . 103

7 Cabling panel with grounding outlets (CPGO) . . . . . . . . . . . . . . . . . . . 105

DN70617303 Id:0900d805804bce7d 3
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i

8 Requirement specifications for external cables of M98 mechanics Flexi


BSC and TCSM3i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
8.1 General requirements for connectors and cable materials . . . . . . . . . . 106
8.2 Requirements for specified coaxial cable assemblies . . . . . . . . . . . . . 106
8.2.1 E1 coaxial unbalanced PCM cable assembly . . . . . . . . . . . . . . . . . . . . 106
8.2.2 Unbalanced (coaxial) external synchronisation cable assembly (CKB) 106
8.3 Requirements for specified twisted pair cable assemblies . . . . . . . . . . 107
8.3.1 10 Base-T /100 Base-TX / 1000Base-T/TX LAN cable assemblies (CNI and
cross-connected LAN cable). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
8.3.2 T1 (E1) balanced PCM cable assembly (CNIS) . . . . . . . . . . . . . . . . . . 107
8.3.3 E1 balanced PCM cable assembly (CNIB) . . . . . . . . . . . . . . . . . . . . . . 107
8.3.4 E1 balanced PCM cable assembly (CNIA) . . . . . . . . . . . . . . . . . . . . . . 107
8.3.5 Current and voltage-controlled alarm cable assembly (CNDC) . . . . . . 108
8.3.6 Alarm cable (CNDE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
8.3.7 Alarm cable (CYV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
8.3.8 Alarm cable (CYR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
8.3.9 Electrical performance requirements for X.25 cable assemblies . . . . . 108
8.3.10 Electrical performance requirements for optical LC cable assemblies (mul-
timode cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
8.3.11 Electrical performance requirements for optical LC cable assemblies (sin-
glemode cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

4 Id:0900d805804bce7d DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i

List of Figures
Figure 1 Connector panel CPETS-G and CPSM cable (front view). . . . . . . . . . . 15
Figure 2 Connector panel CPETS-H (front view) . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 3 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 17
Figure 4 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 19
Figure 5 RJ45 connector cable (CNIB cable type) with four connectors . . . . . . . 35
Figure 6 Connector panel CPETS-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 7 Connector panel CPETS-F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 8 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables . . . 43
Figure 9 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 43
Figure 10 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables . . . 45
Figure 11 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 46
Figure 12 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables . . . 61
Figure 13 RJ45 connector cable (CNIA cable type) with four connectors . . . . . . . 61
Figure 14 CPETC-E panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 15 CPETC-F panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 16 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 68
Figure 17 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 70
Figure 18 CPRD cable assembly (panel end connector mounted) . . . . . . . . . . . . 85
Figure 19 D-connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Figure 20 Panel CPRJ45-A with LAN, alarm, LPT/VDU, and synchronisation interfac-
es - seen from the front of the cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Figure 21 Optical LC connectors, straight type . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 22 Installation of the EXAU-A; mounting on the wall, cabling, and setting the
buzzer jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Figure 23 Peripheral cables; CNM for VDU and CNP for LPT. . . . . . . . . . . . . . . 102
Figure 24 CPGO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Figure 25 Optical LC connectors, straight type . . . . . . . . . . . . . . . . . . . . . . . . . . 105

DN70617303 Id:0900d805804bce7d 5
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i

List of Tables
Table 1 BSC network elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 2 TCSM3i product family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 3 Connector panels and the CPGO used in the Flexi BSC . . . . . . . . . . . . 12
Table 4 E1 trunk cable connector, pin configuration . . . . . . . . . . . . . . . . . . . . . . 17
Table 5 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 17
Table 6 Balanced panel at the BSCC cabinet top in first deliveries . . . . . . . . . . 18
Table 7 Balanced panel at the BSCC cabinet top in upgrade deliveries . . . . . . 18
Table 8 Balanced connector panels for the BSC3i . . . . . . . . . . . . . . . . . . . . . . . 19
Table 9 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 19
Table 10 Balanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 11 Balanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 12 Balanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . . . 35
Table 13 Recommended cable type for E1 trunk cables (CNIB) . . . . . . . . . . . . . 35
Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface . .
36
Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface
38
Table 16 E1 and T1 trunk cable connector, pin configuration . . . . . . . . . . . . . . . . 42
Table 17 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 42
Table 18 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 43
Table 19 Balanced panel at the BSCC cabinet top in first deliveries . . . . . . . . . . 44
Table 20 Balanced panel at the BSCC cabinet top in upgrade deliveries . . . . . . 44
Table 21 Balanced connector panels in the cabling cabinet . . . . . . . . . . . . . . . . . 45
Table 22 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 45
Table 23 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 46
Table 24 Balanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Table 25 Balanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 26 Balanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . . . 60
Table 27 Recommended cable type for T1 trunk cables (CNIS) . . . . . . . . . . . . . 60
Table 28 Recommended cable type for E1 trunk cables (CNIA) . . . . . . . . . . . . . 61
Table 29 Balanced panels in the cabling cabinet - A-interface . . . . . . . . . . . . . . . 62
Table 30 Balanced panels in the cabling cabinet - Ater-interface . . . . . . . . . . . . . 65
Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries . . . . . . . . 68
Table 32 Unbalanced panel at the BSCC cabinet top in upgrade deliveries . . . . 69
Table 33 Unbalanced connector panels for the Flexi BSC . . . . . . . . . . . . . . . . . . 69
Table 34 Recommended cable type for E1 coaxial trunk cables (CPRD) . . . . . . 70
Table 35 Unbalanced panels in first deliveries . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Table 36 Unbalanced panels in upgrade deliveries . . . . . . . . . . . . . . . . . . . . . . . 76
Table 37 Unbalanced connector panels for the TCSM3i . . . . . . . . . . . . . . . . . . . 85
Table 38 Recommended cable type for E1 coaxial trunk cables (CPRD) . . . . . . 85
Table 39 Unbalanced panels in cabling cabinet - A-interface . . . . . . . . . . . . . . . . 87
Table 40 Unbalanced panels in cabling cabinet - Ater-interface . . . . . . . . . . . . . . 90
Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-
nected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Table 42 CNIX cable connector, pin configuration in 1 Gbit/s use (cross-connected
cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

6 Id:0900d805804bce7d DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i

Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-
nected cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table 44 CNI cable connector, pin configuration in 1 Gbit/s use (straight-connected
cable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Table 45 Recommended cable types for LAN cables (CNI and CNIX) . . . . . . . . 94
Table 46 External alarm cabling connectors in the CPRJ45-A panel . . . . . . . . . 95
Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable
with D25 connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs,
AEIx) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Table 49 Signals on panel connector 23 (current-controlled ALS inputs) . . . . . . 98
Table 50 General requirements for external alarm cable CNDE . . . . . . . . . . . . . 99
Table 51 V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration 101
Table 52 Recommended cable types for V.24/V.11 cables (CNI) . . . . . . . . . . . 102
Table 53 The pin configuration for connectors 18 and 19 . . . . . . . . . . . . . . . . . 103
Table 54 Recommended cable types for synchronisation cables (CNI) . . . . . . 103
Table 55 Pin configuration for connectors 20 and 28 . . . . . . . . . . . . . . . . . . . . 104
Table 56 Main characteristics of optical singlemode cables and connectors . . 105
Table 57 Main characteristics of optical multimode cables and connectors . . . 105

DN70617303 Id:0900d805804bce7d 7
Issue 1-0
Connector Panels and External Cables in Flexi BSC
and TCSM3i

8 Id:0900d805804bce7d DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Summary of changes
and TCSM3i

Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.

Issue 1-0
The first issue of Connector Panels and External Cables in Flexi BSC and TCSM3i,
based on Connector Panels and External Cables in BSC3i and TCSM3i. It is included in
Flexi BSC first delivery and upgrade delivery documentation and in TCSM3i delivery
documentation.

DN70617303 Id:0900d805804dcc03 9
Issue 1-0
Overview Connector Panels and External Cables in Flexi BSC
and TCSM3i

1 Overview
This is a description of the connector panels and the related external cables used in the
first-delivery Flexi BSC and in the upgrade-delivery Flexi BSC and in the TCSM3i.
The cabling connecting the equipment to the environment is treated from the point of
view of the Flexi BSC and TCSM3i, indicating how and where the external wiring is con-
nected to.

1.1 Use of product names


Acronyms related to Flexi BSC are presented in the following tables.

BSC = Base Station Controller, a general term for all BSC network elements
General name Product name Explanation
BSCi/BSC2i BSCi High capacity (upgraded) version of the
first generation DX 200 BSC (BSCE)
BSC2i High capacity version of the second gener-
ation DX 200 BSC2
Flexi BSC product BSC3i 660 660 TRX one cabinet configuration,
family upgradable to Flexi BSC
BSC3i 1000/2000 1000 TRX one-cabinet or 2000 TRX two-
cabinet configuration, upgradable to Flexi
BSC
Flexi BSC 3000 TRX one-cabinet configuration (S14)

Table 1 BSC network elements

Acronyms related to TCSM3i are presented in the following table.

TCSM3i high capacity transcoder submultiplexer, TCSM3i


Installation option Product name Explanation
TCSM3i for stand- TCSM3i high capacity transcoder ET interfaces in
alone installation submultiplexer, American National ANSI environment
option Standards Institute (ANSI) version of
TCSM3i
TCSM3i for stand- TCSM3i high capacity transcoder ET interfaces in
alone installation submultiplexer, European Telecom- ETSI environment
option munications Standards Institute
(ETSI) version of TCSM3i
TCSM3i for combined TCSM3i for combined BSC/TCSM STM-1/OC-3 inter-
BSC/TCSM installation installation option faces in the A-inter-
option face

Table 2 TCSM3i product family

1.2 Connector panels


The following connector panels and their external cabling are discussed in this docu-
ment:

10 Id:0900d805804d3524 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Overview
and TCSM3i

CPETS-G and CPETS-H (E1 balanced)


CPETS-E and CPETS-F (E1/T1 balanced)
CPETC-E and CPETC-F (unbalanced)
CPRJ45-A
CPGO
This document also contains Requirement specification for external cables of Flexi BSC
equipment.

1.3 Related information


For information on power distribution, site requirements, cabling and dimensioning prin-
ciples of the Flexi BSC, see Installation Site Requirements for Flexi BSC product Family
and TCSM3i, Engineering for Flexi BSC, and Engineering for TCSM3i.

1.4 Feedback
We are always interested to know whether our manuals provide the information you
need. If you have any comments about this document or any other manual, please pass
them on to your local sales representative.

DN70617303 Id:0900d805804d3524 11
Issue 1-0
Connector panel types in the Flexi BSC Connector Panels and External Cables in Flexi BSC
and TCSM3i

2 Connector panel types in the Flexi BSC


The site (outgoing external) cables enter the network element system through the con-
nector panels. Most of the cables are terminated at the connector panels mounted in the
cabling cabinet or at the equipment cabinet top (small CPETx, CPRJ45-A). Only the
external STM-1/OC-3 trunk cabling and GigE Ethernet interface cabling is routed
through the grounding outlets (CPGO).
The panels are connected by internal cabling through the cartridge back plane to the
rear connectors of the Exchange Terminal plug-in unit ET16 (E1, T1, JT1), Clock and
Tone Generator unit CL3TG-UA and the Hardware Alarm Terminal HWAT-B/-A or
straight to the front connectors of SDH/SONET Exchange Terminal ETS2 and the LAN
Switch plug-in units ESB24-A/ESB26.
The small CPETx panels used at the BSCC cabinet top are optional and ordered sepa-
rately. The small and the large CPETx panels used in the optional cabling cabinet are
delivered with the cabinet. Three cabling cabinet options are available:
Cabling cabinet 2 PCMs / cable (connector panels CPETS-G and CPETS-H)
Cabling cabinet 1 PCM / cable (connector panels CPETS-E and CPETS-F)
Cabling cabinet coaxial PCMs (connector panels CPETC-E and CPETC-F)
Note that in Flexi BSC first deliveries, there is an additional small CPETx connector
panel at the cabling cabinet top.
The panels mounted in the cabling cabinets are listed in the table below.

Panel Panel Connectors Description


type
CPETS-G C11122 24 x RJ45, balanced, 2 For balanced E1 trunk cables.
48 x E1 1 x E1/RJ45 Two external PCM lines are
coupled to each RJ45 plug,
which are terminated to the rear
connectors of the ET16
Exchange Terminal plug-in
units. Capacity 48 PCMs.
CPETS-E C10982 48 x RJ45, balanced For balanced E1, T1 or JT1
48 x E1, 1 trunk cables. One external PCM
T1, JT1 line is coupled to each RJ45
plug, which are terminated to
the rear connectors of the ET16
Exchange Terminal plug-in
units. Capacity 48 PCMs.
CPETC-E C10982 12 x 8 D-connector For unbalanced coaxial E1
48 x E1 4 block unbalanced - trunk cables. One external PCM
coaxial 2 x SMD/E1 line is coupled to each pair of
(Tx, Rx) SMD plugs, which are
terminated to the rear connec-
tors of the ET16 Exchange
Terminal plug-in units. Capacity
48 PCMs.

Table 3 Connector panels and the CPGO used in the Flexi BSC

12 Id:0900d805804d0c7c DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Connector panel types in the Flexi BSC
and TCSM3i

Panel Panel Connectors Description


type
CPETS-H C11122 128 x RJ45, balanced, For balanced E1 trunk cables.
256 x E1 2 2 x E1/RJ45 Two external PCM lines are
coupled to each RJ45 plug,
which are terminated to the rear
connectors of the ET16
Exchange Terminal plug-in
units. Capacity 256 PCMs.
CPETS-F C10982 256 x RJ45, balanced For balanced E1, T1 or JT1
256 x E1, 2 trunk cables. One external PCM
T1, JT1 line is coupled to each RJ45
plug, which are terminated to
the rear connectors of the ET16
Exchange Terminal plug-in
units. Capacity 256 PCMs.
CPETC-F C10982 64 x 8 D-connector For unbalanced coaxial E1
256 x E1 3 block unbalanced - trunk cables. One external PCM
coaxial 2 x SMD/E1 line is coupled to each pair of
(Tx, Rx) SMD plugs, which are
terminated to the rear connec-
tors of the ET16 Exchange
Terminal plug-in units. Capacity
256 PCMs.
CPRJ45-A 109825 16 x RJ45 Interfaces for 100 Mbit/s and 1
2 x BNC Gbit/s LAN uplinks, LPTs and
VDUs, incoming external syn-
2 x D25 chronisation signals, and inputs
1 x D9 and outputs for external alarms.
8 x LC
CPGO C10459 External STM-1/OC-3 trunk
4 cables and GigE Ethernet inter-
face cables

Table 3 Connector panels and the CPGO used in the Flexi BSC (Cont.)

The external cables are connected to the connector panels; therefore, extra grounding
devices are not needed.

DN70617303 Id:0900d805804d0c7c 13
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

3 E1 (PCM) balanced trunk cable panels


(CPETS-G and CPETS-H)

3.1 Connector panels CPETS-G and CPETS-H with RJ45 con-


nectors
The small CPETx connector panel (CPETS-G) and the large CPETx connector panel
(CPETS-H) are used for reducing site cabling as two external PCM lines are connected
from each RJ45 connector. The panels fulfil E1 requirements. They can also be used for
T1 interface if ANSI-specific line protection is not required.
The cabling of the CPETS-G panels is described in the cabling lists delivered in the Site
Documents binder. The CPETS-G is installed at the BSCC cabinet top (one panel) or in
the optional cabling cabinet (a total of four small panels, because there are three small
panels in the cabinet and an additional small panel at the cabling cabinet top in first
deliveries). The installation of the connector panel at the equipment cabinet top requires
the use of Roof adapter (RACP) and the installation of the connector panel at the cabling
cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).
For details of the panel, see figure Connector panel CPETS-G and CPSM cable (front
view).

14 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ET16 CPETS-G
00 02 04 06
01 03 05 07
08 10 12 14
09 11 13 15
16 18 20 22
17 19 21 23
24 26 28 30
25 27 29 31
32 34 36 38
33 35 37 39
40 42 44 46
41 43 45 47

Front view

01 00
0
1 03 02
2
3
05 04
4
5
6 07 06
7 LINE
8 ALARMS 09 08
9
10
11 10
11
12
13 Rear view
14
15

CPSM

DN70457779

Figure 1 Connector panel CPETS-G and CPSM cable (front view)


The cabling of the CPETS-H panels is described in the cabling lists delivered in the Site
Documents binder. The CPETS-H is installed in the optional cabling cabinet (two
panels).
For details of the panel, see figure Connector panel CPETS-H (front view).

DN70617303 Id:0900d805804d10f1 15
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

00 02 04 06 CPETS-H
01 03 05 07
08 10 12 14
09 11 13 15
16 18 20 22
17 19 21 23
24 26 28 30
25 27 29 31
32 34 36 38
33 35 37 39
40 42 44 46
41 43 45 47
48 50 52 54
49 51 53 55
56 58 60 62
57 59 61 63
64 66 68 70
65 67 69 71
72 74 76 78
73 75 77 79
80 82 84 86
81 83 85 87
88 90 92 94
89 91 93 95
96 98 100 102
97 99 101 103
104 106 108 110
105 107 109 111
112 114 116 118
113 115 117 119
120 122 124 126
121 123 125 127
128 130 132 134
129 131 133 135
136 138 140 142
137 139 141 143
144 146 148 150
145 147 149 151
152 154 156 158
153 155 157 159
160 162 164 166
161 163 165 167
168 170 172 174
169 171 173 175
176 178 180 182
177 179 181 183
184 186 188 190
185 187 189 191
192 194 196 198
193 195 197 199
200 202 204 206
201 203 205 207
208 210 212 214
209 211 213 215
216 218 220 222
217 219 221 223
224 226 228 230
225 227 229 231
232 234 236 238
233 235 237 239
240 242 244 246
241 243 245 247
248 250 252 254
249 251 253 255
DN70458754

Figure 2 Connector panel CPETS-H (front view)

3.2 Flexi BSC


Depending on the maximum number ET interfaces, the Flexi BSCi can be used either
with or without a cabling cabinet.

3.2.1 Optional cabling cabinet is not used


The optional cabling cabinet is not needed, if the number ET interfaces needed does not
exceed 48.

16 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

The E1 trunk cable connector and configuration is presented in the following table.

Pin Signal Colour Remarks


1 R White/Blue Incoming direction # 1
2 T Blue
3 R White/Green Incoming direction # 2
4 R White/Orange Outgoing direction # 1
5 T Orange
6 T Green Incoming direction # 2
7 R White/Brown Outgoing direction # 2
8 T Brown

Table 4 E1 trunk cable connector, pin configuration

Recommended cable type for E1 trunk cables (CNIB) for the CPETS-G and CPETS-H
is presented in the following table and figure.

Cable type: 4x(4x2xAWG26/1) 120 , insulated pairs, twisted, double-


shielded, cross section 0.4 mm2
Cable connector: RJ45 modular connector plug (8-pole)

Table 5 Recommended cable type for E1 trunk cables (CNIB)

DN00206525

CONNECTOR 1 2 3 4
Figure 3 RJ45 connector cable (CNIB cable type) with four connectors
The external trunk cable (from the ET panel) and the connector should meet the require-
ments of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The
connector should also meet the requirements of the FCC Part 68.
The following table shows the equipping order of the CPETS-G panel at the cabinet top
in first deliveries.

DN70617303 Id:0900d805804d10f1 17
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC car- From SGC1C- To CPETS-G Front ports in Corresponding external ET numbers
tridge A connector connector CPETS-G panel
position position thorough this
cable
ETC 0 B 19.1A B 00 00,01,02,03 ET368,ET369,ET370,ET371
ETC 0 B 19.1J B 01 04,05,06,07 ET372,ET373,ET374,ET375
ETC 0 B 19.1R B 02 08,09,10,11 ET376,ET377,ET378,ET379
ETC 0 B 19.1Z B 03 12,13,14,15 ET380,ET381,ET382,ET383
ETC 0 B 20.1A B 04 16,17,18,19 ET256,ET257,ET258,ET259
ETC 0 B 20.1J B 05 20,21,22,23 ET260,ET261,ET262,ET263
ETC 0 B 20.1R B 06 24,25,26,27 ET264,ET265,ET266,ET267
ETC 0 B 20.1Z B 07 28,29,30,31 ET268,ET269,ET270,ET271
ETC 0 B 21.1A B 08 32,33,34,35 ET272,ET273,ET274,ET275
ETC 0 B 21.1J B 09 36,37,38,39 ET276,ET277,ET278,ET279
ETC 0 B 21.1R B 10 40,41,42,43 ET280,ET281,ET282,ET283
ETC 0 B 21.1Z B 11 44,45,46,47 ET284,ET285,ET286,ET287

Table 6 Balanced panel at the BSCC cabinet top in first deliveries

The following table shows the equipping order of the CPETS-G panel at the cabinet top
in upgrade deliveries.

ETC car- From GT6C-A To CPETS-G Front ports in Corresponding external ET numbers
tridge connector connector CPETS-G panel
position position through this cable
ETC 0 B 01.1A B 00 00,01,02,03 ET512,ET513,ET514,ET515
ETC 0 B 01.1J B 01 04,05,06,07 ET516,ET517,ET518,ET519
ETC 0 B 01.1R B 02 08,09,10,11 ET520,ET521,ET522,ET523
ETC 0 B 01.1Z B 03 12,13,14,15 ET524,ET525,ET526,ET527
ETC 0 B 02.1A B 04 16,17,18,19 ET528,ET529,ET530,ET531
ETC 0 B 02.1J B 05 20,21,22,23 ET532,ET533,ET534,ET535
ETC 0 B 02.1R B 06 24,25,26,27 ET536,ET537,ET538,ET539
ETC 0 B 02.1Z B 07 28,29,30,31 ET540,ET541,ET542,ET543
ETC 0 B 03.1A B 08 32,33,34,35 ET544,ET545,ET546,ET547
ETC 0 B 03.1J B 09 36,37,38,39 ET548,ET549,ET550,ET551
ETC 0 B 03.1R B 10 40,41,42,43 ET552,ET553,ET554,ET555
ETC 0 B 03.1Z B 11 44,45,46,47 ET556,ET557,ET558,ET559

Table 7 Balanced panel at the BSCC cabinet top in upgrade deliveries

3.2.2 Optional cabling cabinet is used


The cabling cabinet must be used, if more than 48 ET interfaces are needed.

18 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

E1 (PCM) balanced trunk cable panels (CPETS-G and CPETS-H)


The following table shows the connector panels in the cabling cabinet.

Panel Connector panel


number
T00 CPETS-G
0 CPETS-H
1 CPETS-G
2 CPETS-G
3 CPETS-G
4 CPETS-H

Table 8 Balanced connector panels for the BSC3i

The cables and the connectors should meet the requirements of the UL 1459 standard
or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the
requirements of the FCC Part 68.
Recommended cable type for E1 trunk cables (CNIB) is presented in the following table
and figure.

Cable type: 4x(4x2xAWG26/1) 120 , insulated pairs, twisted, double-


shielded, cross section 0.4 mm2
Cable connector: RJ45 modular connector plug (8-pole)

Table 9 Recommended cable type for E1 trunk cables (CNIB)

DN00206525

CONNECTOR 1 2 3 4
Figure 4 RJ45 connector cable (CNIB cable type) with four connectors

Equipping order
The equipping order of the connector panels in the cabling cabinet in first deliveries is
presented in the following table.

DN70617303 Id:0900d805804d10f1 19
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC/GTIC From SGC1C- To panel / connector Front ports in Corresponding external ET


index A connector position balanced panel numbers
position through this cable
ETC 0 B 22.1A Panel 00 / B 00 00,01,02,03 ET256,ET257,ET258,ET259
ETC 0 B 22.1J Panel 00 / B 01 04,05,06,07 ET260,ET261,ET262,ET263
ETC 0 B 22.1R Panel 00 / B 02 08,09,10,11 ET264,ET265,ET266,ET267
ETC 0 B 22.1Z Panel 00 / B 03 12,13,14,15 ET268,ET269,ET270,ET271
ETC 0 B 23.1A Panel 00 / B 04 16,17,18,19 ET304,ET305,ET306,ET307
ETC 0 B 23.1J Panel 00 / B 05 20,21,22,23 ET308,ET309,ET310,ET311
ETC 0 B 23.1R Panel 00 / B 06 24,25,26,27 ET312,ET313,ET314,ET315
ETC 0 B 23.1Z Panel 00 / B 07 28,29,30,31 ET316,ET317,ET318,ET319
ETC 0 B 24.1A Panel 00 / B 08 32,33,34,35 ET320,ET321,ET322,ET323
ETC 0 B 24.1J Panel 00 / B 09 36,37,38,39 ET324,ET325,ET326,ET327
ETC 0 B 24.1R Panel 00 / B 10 40,41,42,43 ET328,ET329,ET330,ET331
ETC 0 B 24.1Z Panel 00 / B 11 44,45,46,47 ET332,ET333,ET334,ET335
ETC 0 B 25.1A Panel 00 / B 12 48,49,50,51 ET336,ET337,ET338,ET339
ETC 0 B 25.1J Panel 00 / B 13 52,53,54,55 ET340,ET341,ET342,ET343
ETC 0 B 25.1R Panel 00 / B 14 56,57,58,59 ET344,ET345,ET346,ET347
ETC 0 B 25.1Z Panel 00 / B 15 60,61,62,63 ET348,ET349,ET350,ET351
ETC 0 B 26.1A Panel 00 / B 16 64,65,66,67 ET352,ET353,ET354,ET355
ETC 0 B 26.1J Panel 00 / B 17 68,69,70,71 ET356,ET357,ET358,ET359
ETC 0 B 26.1R Panel 00 / B 18 72,73,74,75 ET360,ET361,ET362,ET363
ETC 0 B 26.1Z Panel 00 / B 19 76,77,78,79 ET364,ET365,ET366,ET367

ETC 1 B 28.1A Panel 00 / B 20 80,81,82,83 ET640,ET641,ET642,ET643


ETC 1 B 28.1J Panel 00 / B 21 84,85,86,87 ET644,ET645,ET646,ET647
ETC 1 B 28.1R Panel 00 / B 22 88,89,90,91 ET648,ET649,ET650,ET651
ETC 1 B 28.1Z Panel 00 / B 23 92,93,94,95 ET652,ET653,ET654,ET655
ETC 1 B 29.1A Panel 00 / B 24 96,97,98,99 ET624,ET625,ET626,ET627
ETC 1 B 29.1J Panel 00 / B 25 100,101,102,103 ET628,ET629,ET630,ET631
ETC 1 B 29.1R Panel 00 / B 26 104,105,106,107 ET632,ET633,ET634,ET635
ETC 1 B 29.1Z Panel 00 / B 27 108,109,110,111 ET636,ET637,ET638,ET639
ETC 1 B 30.1A Panel 00 / B 28 112,113,114,115 ET512,ET513,ET514,ET515
ETC 1 B 30.1J Panel 00 / B 29 116,117,118,119 ET516,ET517,ET518,ET519
ETC 1 B 30.1R Panel 00 / B 30 120,121,122,123 ET520,ET521,ET522,ET523
ETC 1 B 30.1Z Panel 00 / B 31 124,125,126,127 ET524,ET525,ET526,ET527
ETC 1 B 31.1A Panel 00 / B 32 128,129,130,131 ET528,ET529,ET530,ET531

Table 10 Balanced panels in first deliveries

20 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ETC/GTIC From SGC1C- To panel / connector Front ports in Corresponding external ET


index A connector position balanced panel numbers
position through this cable
ETC 1 B 31.1J Panel 00 / B 33 132,133,134,135 ET532,ET533,ET534,ET535
ETC 1 B 31.1R Panel 00 / B 34 136,137,138,139 ET536,ET537,ET538,ET539
ETC 1 B 31.1Z Panel 00 / B 35 140,141,142,143 ET540,ET541,ET542,ET543
ETC 1 B 32.1A Panel 00 / B 36 144,145,146,147 ET544,ET545,ET546,ET547
ETC 1 B 32.1J Panel 00 / B 37 148,149,150,151 ET548,ET549,ET550,ET551
ETC 1 B 32.1R Panel 00 / B 38 152,153,154,155 ET552,ET553,ET554,ET555
ETC 1 B 32.1Z Panel 00 / B 39 156,157,158,159 ET556,ET557,ET558,ET559
ETC 1 B 33.1A Panel 00 / B 40 160,161,162,163 ET560,ET561,ET562,ET563
ETC 1 B 33.1J Panel 00 / B 41 164,165,166,167 ET564,ET565,ET566,ET567
ETC 1 B 33.1R Panel 00 / B 42 168,169,170,171 ET568,ET569,ET570,ET571
ETC 1 B 33.1Z Panel 00 / B 43 172,173,174,175 ET572,ET573,ET574,ET575
ETC 1 B 34.1A Panel 00 / B 44 176,177,178,179 ET576,ET577,ET578,ET579
ETC 1 B 34.1J Panel 00 / B 45 180,181,182,183 ET580,ET581,ET582,ET583
ETC 1 B 34.1R Panel 00 / B 46 184,185,186,187 ET584,ET585,ET586,ET587
ETC 1 B 34.1Z Panel 00 / B 47 188,189,190,191 ET588,ET589,ET590,ET591
ETC 1 B 35.1A Panel 00 / B 48 192,193,194,195 ET592,ET593,ET594,ET595
ETC 1 B 35.1J Panel 00 / B 49 196,197,198,199 ET596,ET597,ET598,ET599
ETC 1 B 35.1R Panel 00 / B 50 200,201,202,203 ET600,ET601,ET602,ET603
ETC 1 B 35.1Z Panel 00 / B 51 204,205,206,207 ET604,ET605,ET606,ET607
ETC 1 B 36.1A Panel 00 / B 52 208,209,210,211 ET608,ET609,ET610,ET611
ETC 1 B 36.1J Panel 00 / B 53 212,213,214,215 ET612,ET613,ET614,ET615
ETC 1 B 36.1R Panel 00 / B 54 216,217,218,219 ET616,ET617,ET618,ET619
ETC 1 B 36.1Z Panel 00 / B 55 220,221,222,223 ET620,ET621,ET622,ET623

ET1392,ET1393,ET1394,ET139
GTIC 0 B 10.1A Panel 00 / B 56 224,225,226,227 5
ET1396,ET1397,ET1398,ET139
GTIC 0 B 10.1J Panel 00 / B 57 228,229,230,231 9
ET1400,ET1401,ET1402,ET140
GTIC 0 B 10.1R Panel 00 / B 58 232,233,234,235 3
ET1404,ET1405,ET1406,ET140
GTIC 0 B 10.1Z Panel 00 / B 59 236,237,238,239 7
ET1280,ET1281,ET1282,ET128
GTIC 0 B 11.1A Panel 00 / B 60 240,241,242,243 3
ET1284,ET1285,ET1286,ET128
GTIC 0 B 11.1J Panel 00 / B 61 244,245,246,247 7

Table 10 Balanced panels in first deliveries (Cont.)

DN70617303 Id:0900d805804d10f1 21
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC/GTIC From SGC1C- To panel / connector Front ports in Corresponding external ET


index A connector position balanced panel numbers
position through this cable
ET1288,ET1289,ET1290,ET129
GTIC 0 B 11.1R Panel 00 / B 62 248,249,250,251 1
ET1292,ET1293,ET1294,ET129
GTIC 0 B 11.1Z Panel 00 / B 63 252,253,254,255 5

ET1920,ET1921,ET1922,ET192
GTIC 1 B 10.1A Panel 01 / B 00 00,01,02,03 3
ET1924,ET1925,ET1926,ET192
GTIC 1 B 10.1J Panel 01 / B 01 04,05,06,07 7
ET1928,ET1929,ET1930,ET193
GTIC 1 B 10.1R Panel 01 / B 02 08,09,10,11 1
ET1932,ET1933,ET1934,ET193
GTIC 1 B 10.1Z Panel 01 / B 03 12,13,14,15 5
ET1936,ET1937,ET1938,ET193
GTIC 1 B 11.1A Panel 01 / B 04 16,17,18,19 9
ET1940,ET1941,ET1942,ET194
GTIC 1 B 11.1J Panel 01 / B 05 20,21,22,23 3
ET1944,ET1945,ET1946,ET194
GTIC 1 B 11.1R Panel 01 / B 06 24,25,26,27 7
ET1948,ET1949,ET1950,ET195
GTIC 1 B 11.1Z Panel 01 / B 07 28,29,30,31 1
ET1952,ET1953,ET1954,ET195
GTIC 1 B 12.1A Panel 01 / B 08 32,33,34,35 5
ET1956,ET1957,ET1958,ET195
GTIC 1 B 12.1J Panel 01 / B 09 36,37,38,39 9
ET1960,ET1961,ET1962,ET196
GTIC 1 B 12.1R Panel 01 / B 10 40,41,42,43 3
ET1964,ET1965,ET1966,ET196
GTIC 1 B 12.1Z Panel 01 / B 11 44,45,46,47 7

ET1968,ET1969,ET1970,ET197
GTIC 1 B 13.1A Panel 02 / B 00 00,01,02,03 1
ET1972,ET1973,ET1974,ET197
GTIC 1 B 13.1J Panel 02 / B 01 04,05,06,07 5
ET1976,ET1977,ET1978,ET197
GTIC 1 B 13.1R Panel 02 / B 02 08,09,10,11 9
ET1980,ET1981,ET1982,ET198
GTIC 1 B 13.1Z Panel 02 / B 03 12,13,14,15 3
ET1984,ET1985,ET1986,ET198
GTIC 1 B 14.1A Panel 02 / B 04 16,17,18,19 7
ET1988,ET1989,ET1990,ET199
GTIC 1 B 14.1J Panel 02 / B 05 20,21,22,23 1

Table 10 Balanced panels in first deliveries (Cont.)

22 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ETC/GTIC From SGC1C- To panel / connector Front ports in Corresponding external ET


index A connector position balanced panel numbers
position through this cable
ET1992,ET1993,ET1994,ET199
GTIC 1 B 14.1R Panel 02 / B 06 24,25,26,27 5
ET1996,ET1997,ET1998,ET199
GTIC 1 B 14.1Z Panel 02 / B 07 28,29,30,31 9
ET2000,ET2001,ET2002,ET200
GTIC 1 B 15.1A Panel 02 / B 08 32,33,34,35 3
ET2004,ET2005,ET2006,ET200
GTIC 1 B 15.1J Panel 02 / B 09 36,37,38,39 7
ET2008,ET2009,ET2010,ET201
GTIC 1 B 15.1R Panel 02 / B 10 40,41,42,43 1
ET2012,ET2013,ET2014,ET201
GTIC 1 B 15.1Z Panel 02 / B 11 44,45,46,47 5

ET2016,ET2017,ET2018,ET201
GTIC 1 B 16.1A Panel 03 / B 00 00,01,02,03 9
ET2020,ET2021,ET2022,ET202
GTIC 1 B 16.1J Panel 03 / B 01 04,05,06,07 3
ET2024,ET2025,ET2026,ET202
GTIC 1 B 16.1R Panel 03 / B 02 08,09,10,11 7
ET2028,ET2029,ET2030,ET203
GTIC 1 B 16.1Z Panel 03 / B 03 12,13,14,15 1
ET2032,ET2033,ET2034,ET203
GTIC 1 B 17.1A Panel 03 / B 04 16,17,18,19 5
ET2036,ET2037,ET2038,ET203
GTIC 1 B 17.1J Panel 03 / B 05 20,21,22,23 9
ET2040,ET2041,ET2042,ET204
GTIC 1 B 17.1R Panel 03 / B 06 24,25,26,27 3
ET2044,ET2045,ET2046,ET204
GTIC 1 B 17.1Z Panel 03 / B 07 28,29,30,31 7

ET1136,ET1137,ET1138,ET113
ETC 2 B 19.1A Panel 03 / B 08 32,33,34,35 9
ET1140,ET1141,ET1142,ET114
ETC 2 B 19.1J Panel 03 / B 09 36,37,38,39 3
ET1140,ET1141,ET1142,ET114
ETC 2 B 19.1R Panel 03 / B 10 40,41,42,43 3
ET1140,ET1141,ET1142,ET114
ETC 2 B 19.1Z Panel 03 / B 11 44,45,46,47 3

ET1024,ET1025,ET1026,ET102
ETC 2 B 20.1A Panel 04 / B 00 00,01,02,03 7

Table 10 Balanced panels in first deliveries (Cont.)

DN70617303 Id:0900d805804d10f1 23
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC/GTIC From SGC1C- To panel / connector Front ports in Corresponding external ET


index A connector position balanced panel numbers
position through this cable
ET1028,ET1029,ET1030,ET103
ETC 2 B 20.1J Panel 04 / B 01 04,05,06,07 1
ET1032,ET1033,ET1034,ET103
ETC 2 B 20.1R Panel 04 / B 02 08,09,10,11 5
ET1036,ET1037,ET1038,ET103
ETC 2 B 20.1Z Panel 04 / B 03 12,13,14,15 9
ET1040,ET1041,ET1042,ET104
ETC 2 B 21.1A Panel 04 / B 04 16,17,18,19 3
ET1044,ET1045,ET1046,ET104
ETC 2 B 21.1J Panel 04 / B 05 20,21,22,23 7
ET1048,ET1049,ET1050,ET105
ETC 2 B 21.1R Panel 04 / B 06 24,25,26,27 1
ET1052,ET1053,ET1054,ET105
ETC 2 B 21.1Z Panel 04 / B 07 28,29,30,31 5
ET1056,ET1057,ET1058,ET105
ETC 2 B 22.1A Panel 04 / B 08 32,33,34,35 9
ET1060,ET1061,ET1062,ET106
ETC 2 B 22.1J Panel 04 / B 09 36,37,38,39 3
ET1064,ET1065,ET1066,ET106
ETC 2 B 22.1R Panel 04 / B 10 40,41,42,43 7
ET1068,ET1069,ET1070,ET107
ETC 2 B 22.1Z Panel 04 / B 11 44,45,46,47 1
ET1072,ET1073,ET1074,ET107
ETC 2 B 23.1A Panel 04 / B 12 48,49,50,51 5
ET1076,ET1077,ET1078,ET107
ETC 2 B 23.1J Panel 04 / B 13 52,53,54,55 9
ET1080,ET1081,ET1082,ET108
ETC 2 B 23.1R Panel 04 / B 14 56,57,58,59 3
ET1084,ET1085,ET1086,ET108
ETC 2 B 23.1Z Panel 04 / B 15 60,61,62,63 7
ET1088,ET1089,ET1090,ET109
ETC 2 B 24.1A Panel 04 / B 16 64,65,66,67 1
ET1092,ET1093,ET1094,ET109
ETC 2 B 24.1J Panel 04 / B 17 68,69,70,71 5
ET1096,ET1097,ET1098,ET109
ETC 2 B 24.1R Panel 04 / B 18 72,73,74,75 9
ET1100,ET1101,ET1102,ET110
ETC 2 B 24.1Z Panel 04 / B 19 76,77,78,79 3
ET1104,ET1105,ET1106,ET110
ETC 2 B 25.1A Panel 04 / B 20 80,81,82,83 7
ET1108,ET1109,ET1110,ET111
ETC 2 B 25.1J Panel 04 / B 21 84,85,86,87 1

Table 10 Balanced panels in first deliveries (Cont.)

24 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ETC/GTIC From SGC1C- To panel / connector Front ports in Corresponding external ET


index A connector position balanced panel numbers
position through this cable
ET1112,ET1113,ET1114,ET111
ETC 2 B 25.1R Panel 04 / B 22 88,89,90,91 5
ET1116,ET1117,ET1118,ET111
ETC 2 B 25.1Z Panel 04 / B 23 92,93,94,95 9
ET1120,ET1121,ET1122,ET112
ETC 2 B 26.1A Panel 04 / B 24 96,97,98,99 3
ET1124,ET1125,ET1126,ET112
ETC 2 B 26.1J Panel 04 / B 25 100,101,102,103 7
ET1128,ET1129,ET1130,ET113
ETC 2 B 26.1R Panel 04 / B 26 104,105,106,107 1
ET1132,ET1133,ET1134,ET113
ETC 2 B 26.1Z Panel 04 / B 27 108,109,110,111 5

ETC 3 B 28.1A Panel 04 / B 28 112,113,114,115 ET896,ET897,ET898,ET899


ETC 3 B 28.1J Panel 04 / B 29 116,117,118,119 ET900,ET901,ET902,ET903
ETC 3 B 28.1R Panel 04 / B 30 120,121,122,123 ET904,ET905,ET906,ET907
ETC 3 B 28.1Z Panel 04 / B 31 124,125,126,127 ET908,ET909,ET910,ET911
ETC 3 B 29.1A Panel 04 / B 32 128,129,130,131 ET880,ET881,ET882,ET883
ETC 3 B 29.1J Panel 04 / B 33 132,133,134,135 ET884,ET885,ET886,ET887
ETC 3 B 29.1R Panel 04 / B 34 136,137,138,139 ET888,ET889,ET890,ET891
ETC 3 B 29.1Z Panel 04 / B 35 140,141,142,143 ET892,ET893,ET894,ET895
ETC 3 B 30.1A Panel 04 / B 36 144,145,146,147 ET768,ET769,ET770,ET771
ETC 3 B 30.1J Panel 04 / B 37 148,149,150,151 ET772,ET773,ET774,ET775
ETC 3 B 30.1R Panel 04 / B 38 152,153,154,155 ET776,ET777,ET778,ET779
ETC 3 B 30.1Z Panel 04 / B 39 156,157,158,159 ET780,ET781,ET782,ET783
ETC 3 B 31.1A Panel 04 / B 40 160,161,162,163 ET784,ET785,ET786,ET787
ETC 3 B 31.1J Panel 04 / B 41 164,165,166,167 ET788,ET789,ET790,ET791
ETC 3 B 31.1R Panel 04 / B 42 168,169,170,171 ET792,ET793,ET794,ET795
ETC 3 B 31.1Z Panel 04 / B 43 172,173,174,175 ET796,ET797,ET798,ET799
ETC 3 B 32.1A Panel 04 / B 44 176,177,178,179 ET800,ET801,ET802,ET803
ETC 3 B 32.1J Panel 04 / B 45 180,181,182,183 ET804,ET805,ET806,ET807
ETC 3 B 32.1R Panel 04 / B 46 184,185,186,187 ET808,ET809,ET810,ET811
ETC 3 B 32.1Z Panel 04 / B 47 188,189,190,191 ET812,ET813,ET814,ET815
ETC 3 B 33.1A Panel 04 / B 48 192,193,194,195 ET816,ET817,ET818,ET819
ETC 3 B 33.1J Panel 04 / B 49 196,197,198,199 ET820,ET821,ET822,ET823
ETC 3 B 33.1R Panel 04 / B 50 200,201,202,203 ET824,ET825,ET826,ET827
ETC 3 B 33.1Z Panel 04 / B 51 204,205,206,207 ET828,ET829,ET830,ET831

Table 10 Balanced panels in first deliveries (Cont.)

DN70617303 Id:0900d805804d10f1 25
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC/GTIC From SGC1C- To panel / connector Front ports in Corresponding external ET


index A connector position balanced panel numbers
position through this cable
ETC 3 B 34.1A Panel 04 / B 52 208,209,210,211 ET832,ET833,ET834,ET835
ETC 3 B 34.1J Panel 04 / B 53 212,213,214,215 ET836,ET837,ET838,ET839
ETC 3 B 34.1R Panel 04 / B 54 216,217,218,219 ET840,ET841,ET842,ET843
ETC 3 B 34.1Z Panel 04 / B 55 220,221,222,223 ET844,ET845,ET846,ET847
ETC 3 B 35.1A Panel 04 / B 56 224,225,226,227 ET848,ET849,ET850,ET851
ETC 3 B 35.1J Panel 04 / B 57 228,229,230,231 ET852,ET853,ET854,ET855
ETC 3 B 35.1R Panel 04 / B 58 232,233,234,235 ET856,ET857,ET858,ET859
ETC 3 B 35.1Z Panel 04 / B 59 236,237,238,239 ET860,ET861,ET862,ET863
ETC 3 B 36.1A Panel 04 / B 60 240,241,242,243 ET864,ET865,ET866,ET867
ETC 3 B 36.1J Panel 04 / B 61 244,245,246,247 ET868,ET869,ET870,ET871
ETC 3 B 36.1R Panel 04 / B 62 248,249,250,251 ET872,ET873,ET874,ET875
ETC 3 B 36.1Z Panel 04 / B 63 252,253,254,255 ET876,ET877,ET878,ET879

ET1296,ET1297,ET1298,ET129
GTIC 0 B 12.1A Panel T00 / B 00 00,01,02,03 9
ET1300,ET1301,ET1302,ET130
GTIC 0 B 12.1J Panel T00 / B 01 04,05,06,07 3
ET1304,ET1305,ET1306,ET130
GTIC 0 B 12.1R Panel T00 / B 02 08,09,10,11 7
ET1308,ET1309,ET1310,ET131
GTIC 0 B 12.1Z Panel T00 / B 03 12,13,14,15 1
ET1312,ET1313,ET1314,ET131
GTIC 0 B 13.1A Panel T00 / B 04 16,17,18,19 5
ET1316,ET1317,ET1318,ET131
GTIC 0 B 13.1J Panel T00 / B 05 20,21,22,23 9
ET1320,ET1321,ET1322,ET132
GTIC 0 B 13.1R Panel T00 / B 06 24,25,26,27 3
ET1324,ET1325,ET1326,ET132
GTIC 0 B 13.1Z Panel T00 / B 07 28,29,30,31 7
ET1328,ET1329,ET1330,ET133
GTIC 0 B 14.1A Panel T00 / B 08 32,33,34,35 1
ET1332,ET1333,ET1334,ET133
GTIC 0 B 14.1J Panel T00 / B 09 36,37,38,39 5
ET1336,ET1337,ET1338,ET133
GTIC 0 B 14.1R Panel T00 / B 10 40,41,42,43 9
ET1340,ET1341,ET1342,ET134
GTIC 0 B 14.1Z Panel T00 / B 11 44,45,46,47 3

Table 10 Balanced panels in first deliveries (Cont.)

The equipping order of the connector panels in the cabling cabinet in upgrade deliveries
is presented in the following table.

26 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ETC 0 B 04.1A Panel 04 / B 61 244,245,246,247 ET560,ET561,ET562,ET563
ETC 0 B 04.1J Panel 04 / B 62 248,249,250,251 ET564,ET565,ET566,ET567
ETC 0 B 04.1R Panel 04 / B 63 252,253,254,255 ET568,ET569,ET570,ET571
ETC 0 B 04.1Z Panel 04 / B 58 232,233,234,235 ET572,ET573,ET574,ET575
ETC 1 B 01.1A Panel 04 / B 59 236,237,238,239 ET576,ET577,ET578,ET579
ETC 1 B 01.1J Panel 04 / B 60 240,241,242,243 ET580,ET581,ET582,ET583
ETC 1 B 01.1R Panel 04 / B 55 220,221,222,223 ET584,ET585,ET586,ET587
ETC 1 B 01.1Z Panel 04 / B 56 224,225,226,227 ET588,ET589,ET590,ET591
ETC 1 B 02.1A Panel 04 / B 57 228,229,230,231 ET592,ET593,ET594,ET595
ETC 1 B 02.1J Panel 04 / B 52 208,209,210,211 ET596,ET597,ET598,ET599
ETC 1 B 02.1R Panel 04 / B 53 212,213,214,215 ET600,ET601,ET602,ET603
ETC 1 B 02.1Z Panel 04 / B 54 216,217,218,219 ET604,ET605,ET606,ET607
ETC 1 B 03.1A Panel 04 / B 49 196,197,198,199 ET608,ET609,ET610,ET611
ETC 1 B 03.1J Panel 04 / B 50 200,201,202,203 ET612,ET613,ET614,ET615
ETC 1 B 03.1R Panel 04 / B 51 204,205,206,207 ET616,ET617,ET618,ET619
ETC 1 B 03.1Z Panel 04 / B 47 188,189,190,191 ET620,ET621,ET622,ET623
ETC 1 B 04.1A Panel 04 / B 48 192,193,194,195 ET624,ET625,ET626,ET627
ETC 1 B 04.1J Panel 04 / B 44 176,177,178,179 ET628,ET629,ET630,ET631
ETC 1 B 04.1R Panel 04 / B 45 180,181,182,183 ET632,ET633,ET634,ET635
ETC 1 B 04.1Z Panel 04 / B 46 184,185,186,187 ET636,ET637,ET638,ET639
GTIC 0 / B 01.1A (GTIC 0)
ETC 5 / B03.1A (ETC 5) Panel 04 / B 41 164,165,166,167 ET904,ET905,ET906,ET907
GTIC 0 / B 01.1J (GTIC 0) /
ETC 5 B03.1J (ETC 5) Panel 04 / B 42 168,169,170,171 ET908,ET909,ET910,ET911
GTIC 0 / B 01.1R (GTIC 0)
ETC 5 / B03.1R (ETC 5) Panel 04 / B 43 172,173,174,175 ET912,ET913,ET914,ET915
GTIC 0 / B 01.1Z (GTIC 0)
ETC 5 / B03.1Z (ETC 5) Panel 04 / B 38 152,153,154,155 ET916,ET917,ET918,ET919
GTIC 0 / B 02.1A (GTIC 0)
ETC 5 / B04.1A (ETC 5) Panel 04 / B 39 156,157,158,159 ET920,ET921,ET922,ET923
GTIC 0 / B 02.1J (GTIC 0) /
ETC 5 B04.1J (ETC 5) Panel 04 / B 40 160,161,162,163 ET924,ET925,ET926,ET927
GTIC 0 / B 02.1R (GTIC 0)
ETC 5 / B04.1R (ETC 5) Panel 04 / B 35 140,141,142,143 ET928,ET929,ET930,ET931
GTIC 0 / B 02.1Z (GTIC 0)
ETC 5 / B04.1Z (ETC 5) Panel 04 / B 36 144,145,146,147 ET932,ET933,ET934,ET935

Table 11 Balanced panels in upgrade deliveries

DN70617303 Id:0900d805804d10f1 27
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
GTIC 0 / B 03.1A (GTIC 0)
ETC 5 / B05.1A (ETC 5) Panel 04 / B 37 148,149,150,151 ET936,ET937,ET938,ET939
GTIC 0 / B 03.1J (GTIC 0) /
ETC 5 B05.1J (ETC 5) Panel 04 / B 32 128,129,130,131 ET940,ET941,ET942,ET943
GTIC 0 / B 03.1R (GTIC 0)
ETC 5 / B05.1R (ETC 5) Panel 04 / B 33 132,133,134,135 ET944,ET945,ET946,ET947
GTIC 0 / B 03.1Z (GTIC 0)
ETC 5 / B05.1Z (ETC 5) Panel 04 / B 34 136,137,138,139 ET948,ET949,ET950,ET951
GTIC 0 / B 04.1A (GTIC 0)
ETC 5 / B06.1A (ETC 5) Panel 04 / B 29 116,117,118,119 ET816,ET817,ET818,ET819
GTIC 0 / B 04.1J (GTIC 0) /
ETC 5 B06.1J (ETC 5) Panel 04 / B 30 120,121,122,123 ET820,ET821,ET822,ET823
GTIC 0 / B 04.1R (GTIC 0)
ETC 5 / B06.1R (ETC 5) Panel 04 / B 31 124,125,126,127 ET824,ET825,ET826,ET827
GTIC 0 / B 04.1Z (GTIC 0)
ETC 5 / B06.1Z (ETC 5) Panel 04 / B 26 104,105,106,107 ET828,ET829,ER830,ET831
GTIC 0 / B 05.1A (GTIC 0) ET1072,ET1073,ET1074,ET1
ETC 5 / B07.1A (ETC 5) Panel 04 / B 27 108,109,110,111 075
GTIC 0 / B 05.1J (GTIC 0) / ET1076,ET1077,ET1078,ET1
ETC 5 B07.1J (ETC 5) Panel 04 / B 28 112,113,114,115 079
GTIC 0 / B 05.1R (GTIC 0) ET1080,ET1081,ET1082,ET1
ETC 5 / B07.1R (ETC 5) Panel 04 / B 23 92,93,94,95 083
GTIC 0 / B 05.1Z (GTIC 0) ET1084,ET1085,ET1086,ET1
ETC 5 / B07.1Z (ETC 5) Panel 04 / B 24 96,97,98,99 087
GTIC 0 / B 06.1A (GTIC 0) ET1328,ET1329,ET1330,ET1
ETC 5 / B08.1A (ETC 5) Panel 04 / B 25 100,101,102,103 331
GTIC 0 / B 06.1J (GTIC 0) / ET1332,ET1333,ET1334,ET1
ETC 5 B08.1J (ETC 5) Panel 04 / B 20 80,81,82,83 335
GTIC 0 / B 06.1R (GTIC 0) ET1336,ET1337,ET1338,ET1
ETC 5 / B08.1R (ETC 5) Panel 04 / B 21 84,85,86,87 339
GTIC 0 / B 06.1Z (GTIC 0) ET1340,ET1341,ET1342,ET1
ETC 5 / B08.1Z (ETC 5) Panel 04 / B 22 88,89,90,91 343
ET1792,ET1793,ET1794,ET1
GTIC 0 B 07.1A Panel 04 / B 17 68,69,70,71 795
ET1796,ET1797,ET1798,ET1
GTIC 0 B 07.1J Panel 04 / B 18 72,73,74,75 799
ET1800,ET1801,ET1802,ET1
GTIC 0 B 07.1R Panel 04 / B 19 76,77,78,79 803
ET1804,ET1805,ET1806,ET1
GTIC 0 B 07.1Z Panel 04 / B 15 60,61,62,63 807
ET1808,ET1809,ET1810,ET1
GTIC 0 B 08.1A Panel 04 / B 16 64,65,66,67 811

Table 11 Balanced panels in upgrade deliveries (Cont.)

28 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1812,ET1813,ET1814,ET1
GTIC 0 B 08.1J Panel 04 / B 12 48,49,50,51 815
ET1816,ET1817,ET1818,ET1
GTIC 0 B 08.1R Panel 04 / B 13 52,53,54,55 819
ET1820,ET1821,ET1822,ET1
GTIC 0 B 08.1Z Panel 04 / B 14 56,57,58,59 823
ET1408,ET1409,ET1410,ET1
GTIC 1 B 01.1A Panel 04 / B 09 36,37,38,39 411
ET1412,ET1413,ET1414,ET1
GTIC 1 B 01.1J Panel 04 / B 10 40,41,42,43 415
ET1416,ET1417,ET1418,ET1
GTIC 1 B 01.1R Panel 04 / B 11 44,45,46,47 419
ET1420,ET1421,ET1422,ET1
GTIC 1 B 01.1Z Panel 04 / B 06 24,25,26,27 423
ET1424,ET1425,ET1426,ET1
GTIC 1 B 02.1A Panel 04 / B 07 28,29,30,31 427
ET1428,ET1429,ET1430,ET1
GTIC 1 B 02.1J Panel 04 / B 08 32,33,34,35 431
ET1432,ET1433,ET1434,ET1
GTIC 1 B 02.1R Panel 04 / B 03 12,13,14,15 435
ET1436,ET1437,ET1438,ET1
GTIC 1 B 02.1Z Panel 04 / B 04 16,17,18,19 439
ET1440,ET1441,ET1442,ET1
GTIC 1 B 03.1A Panel 04 / B 05 20,21,22,23 443
ET1444,ET1445,ET1446,ET1
GTIC 1 B 03.1J Panel 04 / B 00 00,01,02,03 447
ET1448,ET1449,ET1450,ET1
GTIC 1 B 03.1R Panel 04 / B 01 04,05,06,07 451
ET1452,ET1453,ET1454,ET1
GTIC 1 B 03.1Z Panel 04 / B 02 08,09,10,11 455

ET1456,ET1457,ET1458,ET1
GTIC 1 B 04.1A Panel 03 / B 09 36,37,38,39 459
ET1460,ET1461,ET1462,ET1
GTIC 1 B 04.1J Panel 03 / B 10 40,41,42,43 463
ET1464,ET1465,ET1466,ET1
GTIC 1 B 04.1R Panel 03 / B 11 44,45,46,47 467
ET1468,ET1469,ET1470,ET1
GTIC 1 B 04.1Z Panel 03 / B 06 24,25,26,27 471
ET1472,ET1473,ET1474,ET1
GTIC 1 B 05.1A Panel 03 / B 07 28,29,30,31 475

Table 11 Balanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d805804d10f1 29
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1476,ET1477,ET1478,ET1
GTIC 1 B 05.1J Panel 03 / B 08 32,33,34,35 479
ET1480,ET1481,ET1482,ET1
GTIC 1 B 05.1R Panel 03 / B 03 12,13,14,15 483
ET1484,ET1485,ET1486,ET1
GTIC 1 B 05.1Z Panel 03 / B 04 16,17,18,19 487
ET1488,ET1489,ET1490,ET1
GTIC 1 B 06.1A Panel 03 / B 05 20,21,22,23 491
ET1492,ET1493,ET1494,ET1
GTIC 1 B 06.1J Panel 03 / B 00 00,01,02,03 495
ET1496,ET1497,ET1498,ET1
GTIC 1 B 06.1R Panel 03 / B 01 04,05,06,07 499
ET1500,ET1501,ET1502,ET1
GTIC 1 B 06.1Z Panel 03 / B 02 08,09,10,11 503

ET1504,ET1505,ET1506,ET1
GTIC 1 B 07.1A Panel 02 / B 09 36,37,38,39 507
ET1508,ET1509,ET1510,ET1
GTIC 1 B 07.1J Panel 02 / B 10 40,41,42,43 511
ET1512,ET1513,ET1514,ET1
GTIC 1 B 07.1R Panel 02 / B 11 44,45,46,47 515
ET1516,ET1517,ET1518,ET1
GTIC 1 B 07.1Z Panel 02 / B 06 24,25,26,27 519
ET1520,ET1521,ET1522,ET1
GTIC 1 B 08.1A Panel 02 / B 07 28,29,30,31 523
ET1524,ET1525,ET1526,ET1
GTIC 1 B 08.1J Panel 02 / B 08 32,33,34,35 527
ET1528,ET1529,ET1530,ET1
GTIC 1 B 08.1R Panel 02 / B 03 12,13,14,15 531
ET1532,ET1533,ET1534,ET1
GTIC 1 B 08.1Z Panel 02 / B 04 16,17,18,19 535
ET1344,ET1345,ET1346,ET1
ETC 2 B 01.1A Panel 02 / B 05 20,21,22,23 347
ET1348,ET1349,ET1350,ET1
ETC 2 B 01.1J Panel 02 / B 00 00,01,02,03 351
ET1352,ET1353,ET1354,ET1
ETC 2 B 01.1R Panel 02 / B 01 04,05,06,07 355
ET1356,ET1357,ET1358,ET1
ETC 2 B 01.1Z Panel 02 / B 02 08,09,10,11 359

ET1360,ET1361,ET1362,ET1
ETC 2 B 02.1A Panel 01 / B 09 36,37,38,39 363

Table 11 Balanced panels in upgrade deliveries (Cont.)

30 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1364,ET1365,ET1366,ET1
ETC 2 B 02.1J Panel 01 / B 10 40,41,42,43 367
ET1368,ET1369,ET1370,ET1
ETC 2 B 02.1R Panel 01 / B 11 44,45,46,47 371
ET1372,ET1373,ET1374,ET1
ETC 2 B 02.1Z Panel 01 / B 06 24,25,26,27 375
ET1376,ET1377,ET1378,ET1
ETC 2 B 03.1A Panel 01 / B 07 28,29,30,31 379
ET1380,ET1381,ET1382,ET1
ETC 2 B 03.1J Panel 01 / B 08 32,33,34,35 383
ET1384,ET1385,ET1386,ET1
ETC 2 B 03.1R Panel 01 / B 03 12,13,14,15 387
ET1388,ET1389,ET1390,ET1
ETC 2 B 03.1Z Panel 01 / B 04 16,17,18,19 391
ET1392,ET1393,ET1394,ET1
ETC 2 B 04.1A Panel 01 / B 05 20,21,22,23 395
ET1396,ET1397,ET1398,ET1
ETC 2 B 04.1J Panel 01 / B 00 00,01,02,03 399
ET1400,ET1401,ET1402,ET1
ETC 2 B 04.1R Panel 01 / B 01 04,05,06,07 403
ET1404,ET1405,ET1406,ET1
ETC 2 B 04.1Z Panel 01 / B 02 08,09,10,11 407

ET1600,ET1601,ET1602,ET1
ETC 2 B 05.1A Panel 00 / B 61 244,245,246,247 603
ET1604,ET1605,ET1606,ET1
ETC 2 B 05.1J Panel 00 / B 62 248,249,250,251 607
ET1608,ET1609,ET1610,ET1
ETC 2 B 05.1R Panel 00 / B 63 252,253,254,255 611
ET1612,ET1613,ET1614,ET1
ETC 2 B 05.1Z Panel 00 / B 58 232,233,234,235 615
ET1616,ET1617,ET1618,ET1
ETC 2 B 06.1A Panel 00 / B 59 236,237,238,239 619
ET1620,ET1621,ET1622,ET1
ETC 2 B 06.1J Panel 00 / B 60 240,241,242,243 623
ET1624,ET1625,ET1626,ET1
ETC 2 B 06.1R Panel 00 / B 55 220,221,222,223 627
ET1628,ET1629,ET1630,ET1
ETC 2 B 06.1Z Panel 00 / B 56 224,225,226,227 631
ET1632,ET1633,ET1634,ET1
ETC 2 B 07.1A Panel 00 / B 57 228,229,230,231 635

Table 11 Balanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d805804d10f1 31
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1636,ET1637,ET1638,ET1
ETC 2 B 07.1J Panel 00 / B 52 208,209,210,211 639
ET1640,ET1641,ET1642,ET1
ETC 2 B 07.1R Panel 00 / B 53 212,213,214,215 643
ET1644,ET1645,ET1646,ET1
ETC 2 B 07.1Z Panel 00 / B 54 216,217,218,219 647
ET1648,ET1649,ET1650,ET1
ETC 2 B 08.1A Panel 00 / B 49 196,197,198,199 651
ET1652,ET1653,ET1654,ET1
ETC 2 B 08.1J Panel 00 / B 50 200,201,202,203 655
ET1656,ET1657,ET1658,ET1
ETC 2 B 08.1R Panel 00 / B 51 204,205,206,207 659
ET1660,ET1661,ET1662,ET1
ETC 2 B 08.1Z Panel 00 / B 47 188,189,190,191 663
ET1664,ET1665,ET1666,ET1
ETC 3 B 01.1A Panel 00 / B 48 192,193,194,195 667
ET1668,ET1669,ET1670,ET1
ETC 3 B 01.1J Panel 00 / B 44 176,177,178,179 671
ET1672,ET1673,ET1674,ET1
ETC 3 B 01.1R Panel 00 / B 45 180,181,182,183 675
ET1676,ET1677,ET1678,ET1
ETC 3 B 01.1Z Panel 00 / B 46 184,185,186,187 679
ET1680,ET1681,ET1682,ET1
ETC 3 B 02.1A Panel 00 / B 41 164,165,166,167 683
ET1684,ET1685,ET1686,ET1
ETC 3 B 02.1J Panel 00 / B 42 168,169,170,171 687
ET1688,ET1689,ET1690,ET1
ETC 3 B 02.1R Panel 00 / B 43 172,173,174,175 691
ET1692,ET1693,ET1694,ET1
ETC 3 B 02.1Z Panel 00 / B 38 152,153,154,155 695
ET1696,ET1697,ET1698,ET1
ETC 3 B 03.1A Panel 00 / B 39 156,157,158,159 699
ET1700,ET1701,ET1702,ET1
ETC 3 B 03.1J Panel 00 / B 40 160,161,162,163 703
ET1704,ET1705,ET1706,ET1
ETC 3 B 03.1R Panel 00 / B 35 140,141,142,143 707
ET1708,ET1709,ET1710,ET1
ETC 3 B 03.1Z Panel 00 / B 36 144,145,146,147 711
ET1712,ET1713,ET1714,ET1
ETC 3 B 04.1A Panel 00 / B 37 148,149,150,151 715
ET1716,ET1717,ET1718,ET1
ETC 3 B 04.1J Panel 00 / B 32 128,129,130,131 719

Table 11 Balanced panels in upgrade deliveries (Cont.)

32 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1720,ET1721,ET1722,ET1
ETC 3 B 04.1R Panel 00 / B 33 132,133,134,135 723
ET1724,ET1725,ET1726,ET1
ETC 3 B 04.1Z Panel 00 / B 34 136,137,138,139 727
ET1728,ET1729,ET1730,ET1
ETC 3 B 05.1A Panel 00 / B 29 116,117,118,119 731
ET1732,ET1733,ET1734,ET1
ETC 3 B 05.1J Panel 00 / B 30 120,121,122,123 735
ET1736,ET1737,ET1738,ET1
ETC 3 B 05.1R Panel 00 / B 31 124,125,126,127 739
ET1740,ET1741,ET1742,ET1
ETC 3 B 05.1Z Panel 00 / B 26 104,105,106,107 743
ET1744,ET1745,ET1746,ET1
ETC 3 B 06.1A Panel 00 / B 27 108,109,110,111 747
ET1748,ET1749,ET1750,ET1
ETC 3 B 06.1J Panel 00 / B 28 112,113,114,115 751
ET1752,ET1753,ET1754,ET1
ETC 3 B 06.1R Panel 00 / B 23 92,93,94,95 755
ET1756,ET1757,ET1758,ET1
ETC 3 B 06.1Z Panel 00 / B 24 96,97,98,99 759
ET1760,ET1761,ET1762,ET1
ETC 3 B 07.1A Panel 00 / B 25 100,101,102,103 763
ET1764,ET1765,ET1766,ET1
ETC 3 B 07.1J Panel 00 / B 20 80,81,82,83 767
ET1768,ET1769,ET1770,ET1
ETC 3 B 07.1R Panel 00 / B 21 84,85,86,87 771
ET1772,ET1773,ET1774,ET1
ETC 3 B 07.1Z Panel 00 / B 22 88,89,90,91 775
ET1776,ET1777,ET1778,ET1
ETC 3 B 08.1A Panel 00 / B 17 68,69,70,71 779
ET1780,ET1781,ET1782,ET1
ETC 3 B 08.1J Panel 00 / B 18 72,73,74,75 783
ET1784,ET1785,ET1786,ET1
ETC 3 B 08.1R Panel 00 / B 19 76,77,78,79 787
ET1788,ET1789,ET1790,ET1
ETC 3 B 08.1Z Panel 00 / B 15 60,61,62,63 791
ET1920,ET1921,ET1922,ET1
ETC 4 B 01.1A Panel 00 / B 16 64,65,66,67 923
ET1924,ET1925,ET1926,ET1
ETC 4 B 01.1J Panel 00 / B 12 48,49,50,51 927
ET1928,ET1929,ET1930,ET1
ETC 4 B 01.1R Panel 00 / B 13 52,53,54,55 931

Table 11 Balanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d805804d10f1 33
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1932,ET1933,ET1934,ET1
ETC 4 B 01.1Z Panel 00 / B 14 56,57,58,59 935
ET1936,ET1937,ET1938,ET1
ETC 4 B 02.1A Panel 00 / B 09 36,37,38,39 939
ET1940,ET1941,ET1942,ET1
ETC 4 B 02.1J Panel 00 / B 10 40,41,42,43 943
ET1944,ET1945,ET1946,ET1
ETC 4 B 02.1R Panel 00 / B 11 44,45,46,47 947
ET1948,ET1949,ET1950,ET1
ETC 4 B 02.1Z Panel 00 / B 06 24,25,26,27 951
ET1952,ET1953,ET1954,ET1
ETC 4 B 03.1A Panel 00 / B 07 28,29,30,31 955
ET1956,ET1957,ET1958,ET1
ETC 4 B 03.1J Panel 00 / B 08 32,33,34,35 959
ET1960,ET1961,ET1962,ET1
ETC 4 B 03.1R Panel 00 / B 03 12,13,14,15 963
ET1964,ET1965,ET1966,ET1
ETC 4 B 03.1Z Panel 00 / B 04 16,17,18,19 967
ET1968,ET1969,ET1970,ET1
ETC 4 B 04.1A Panel 00 / B 05 20,21,22,23 971
ET1972,ET1973,ET1974,ET1
ETC 4 B 04.1J Panel 00 / B 00 00,01,02,03 975
ET1976,ET1977,ET1978,ET1
ETC 4 B 04.1R Panel 00 / B 01 04,05,06,07 979
ET1980,ET1981,ET1982,ET1
ETC 4 B 04.1Z Panel 00 / B 02 08,09,10,11 983

Table 11 Balanced panels in upgrade deliveries (Cont.)

3.3 TCSM3i
Two installation options of the third-generation Transcoder Submultiplexer are available:
the TCSM3i for stand-alone installation option and the TCSM3i for combined
BSC/TCSM installation option. The TCSM3i for stand-alone installation option always
has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does
not have a cabling cabinet.

3.3.1 TCSM3i for stand-alone installation option


In the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted
to the TCSA cabinet.

E1 (PCM) balanced trunk cable panel (CPETS-H)


Two large balanced CPETS-H connector panels are used in the cabling cabinet
mounted to the TCSA cabinet.

34 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

Panel Connector panel


number
0 CPETS-H
1 CPBP
2 CPBP
3 CPBP
4 CPETS-H

Table 12 Balanced connector panels for the TCSM3i

The cables and connectors should meet the requirements of the UL 1459 standard or
the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the
requirements of the FCC Part 68.
Recommended cable type for E1 trunk cables (CNIB) is presented in the following table
and figure.

Cable type: 4x(4x2xAWG26/1) 120 , insulated pairs, twisted, double-


shielded, cross section 0.4 mm2
Cable connector: RJ45 modular connector plug (8-pole)

Table 13 Recommended cable type for E1 trunk cables (CNIB)

DN00206525

CONNECTOR 1 2 3 4
Figure 5 RJ45 connector cable (CNIB cable type) with four connectors

Equipping order
Equipping of ETs proceeds in steps. The equipping order in the cabling cabinet is pre-
sented in the following table.

DN70617303 Id:0900d805804d10f1 35
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-H panel
connector position
position
ETC 0 B 01.1A Panel 0 / B 00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 15
ETC 1 B 04.1Z Panel 0 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 16
ETC 0 B 03.1A Panel 0 / B32 128, 129, 130, 131 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 132, 133, 134, 135 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 02

Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface

36 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-H panel
connector position
position
ETC 0 B 03.1R Panel 0 / B34 136, 137, 138, 139 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 140, 141, 142, 143 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 144, 145, 146, 147 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 148, 149, 150, 151 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 152, 153, 154, 155 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 156, 157, 158, 159 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 160, 161, 162, 163 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 164, 165, 166, 167 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 168, 169, 170, 171 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 172, 173, 174, 175 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 176, 177, 178, 179 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 180, 181, 182, 183 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 184, 185, 186, 187 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 188, 189, 190, 191 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 192, 193, 194, 195 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 196, 197, 198, 199 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 200, 201, 202, 203 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 204, 205, 206, 207 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 208, 209, 210, 211 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 212, 213, 214, 215 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 216, 217, 218, 219 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 220, 221, 222, 223 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 224, 225, 226, 227 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 228, 229, 230, 231 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 232, 233, 234, 235 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 236, 237, 238, 239 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 240, 241, 242, 243 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 244, 245, 246, 247 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 248, 249, 250, 251 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 252, 253, 254, 255 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 16

ETC 0 B 05.1A Panel 4 / B00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 01
ETC 0 B 05.1J Panel 4 / B01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 03

Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface (Cont.)

DN70617303 Id:0900d805804d10f1 37
Issue 1-0
E1 (PCM) balanced trunk cable panels (CPETS-G and Connector Panels and External Cables in Flexi BSC
CPETS-H) and TCSM3i

ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-H panel
connector position
position
ETC 0 B 05.1Z Panel 4 / B03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 16

Table 14 CPETS-H balanced panels in the TCSM3i cabling cabinet - A-interface (Cont.)

From car- TR3 unit slot From ET16 slot and ET panel / front ports
tridge connector position through this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 128, 129, 130, 131

Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface

38 Id:0900d805804d10f1 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) balanced trunk cable panels (CPETS-G and
and TCSM3i CPETS-H)

From car- TR3 unit slot From ET16 slot and ET panel / front ports
tridge connector position through this cable
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 132, 133, 134, 135
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 136, 137, 138, 139
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 140, 141, 142, 143
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 144, 145, 146, 147
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 148, 149, 150, 151
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 152, 153, 154, 155
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 156, 157, 158, 159
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 160, 161, 162, 163
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 164, 165, 166, 167
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 168, 169, 170, 171
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 172, 173, 174, 175
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 176, 177, 178, 179
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 180, 181, 182, 183
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 184, 185, 186, 187
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 188, 189, 190, 191
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 192, 193, 194, 195
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 196, 197, 198, 199
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 200, 201, 202, 203
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 204, 205, 206, 207
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 208, 209, 210, 211
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 212, 213, 214, 215
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 216, 217, 218, 219
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 220, 221, 222, 223
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C car-
tridge is used for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used
for transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC
and the other half for the other BSC).

Table 15 CPETS-H balanced panels in the TCSM3i cabling cabinet - Ater-interface

3.3.2 TCSM3i for combined BSC/TCSM installation option


The cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined
BSC/TCSM installation option. Instead, the optical cabling from the front connectors of
the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.

DN70617303 Id:0900d805804d10f1 39
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

4 E1/T1 (PCM) balanced trunk cable panels


(CPETS-E and CPETS-F)

4.1 Connector panels CPETS-E and CPETS-F with RJ45 con-


nectors
The small CPETS-E connector panel and the large CPETS-F connector panels are used
for E1/T1 (PCM) balanced trunk cables.
Cabling of the CPETS-E panels is described in the cabling lists delivered in the Site Doc-
uments binder. The CPETS-E is installed at the BSCC cabinet top (one panel) or in the
optional cabling cabinet (a total of four small panels, because there are three small
panels in the cabinet and an additional small panel at the cabling cabinet top in first
deliveries). The installation of the connector panel at the equipment cabinet top requires
the use of Roof adapter (RACP) and the installation of the connector panel at the cabling
cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).
For details of the panel, see figure Connector panel CPETS-E.

CPETS-E
00 01 02 03 04 05 06 07 08 09 10 11

12 13 14 15 16 17 18 19 20 21 22 23

24 24 26 27 28 29 30 31 32 33 34 35

36 37 38 39 40 41 42 43 44 45 46 47

DN0626746
Figure 6 Connector panel CPETS-E
Cabling of the CPETS-F panels is described in the cabling lists delivered in the Site Doc-
uments binder. The CPETS-F is installed in the optional cabling cabinet.
For details of the panel, see figure Connector panel CPETS-F.

40 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

00 01 02 03 04 05 06 07 08 09 10 11

CPETS-F
12 13 14 15 16 17 18 19 20 21 22 23

24 25 26 27 28 29 30 31 32 33 34 35

36 37 38 39 40 41 42 43 44 45 46 47

48 49 50 51 52 53 54 55 56 57 58 59

60 61 62 63 64 65 66 67

68 69 70 71 72 73 74 75 76 77 78 79

80 81 82 83 84 85 86 87 88 89 90 91

92 93 94 95 96 97 98 99 100 101 102 103

104 105 106 107 108 109 110 111 112 113 114 115

116 117 118 119 120 121 122 123 124 125 126 127

128 129 130 131 132 133 134 135 136 137 138 139

140 141 142 143 144 145 146 147 148 149 150 151

152 153 154 155 156 157 158 159 160 161 162 163

164 165 166 167 168 169 170 171 172 173 174 175

176 177 178 179 180 181 182 183 184 185 186 187

188 189 190 191 192 193 194 195

196 197 198 199 200 201 202 203 204 205 206 207

208 209 210 211 212 213 214 215 216 217 218 219

220 221 222 223 224 225 226 227 228 229 230 231

232 233 234 235 236 237 238 239 240 241 242 243

244 245 246 247 248 249 250 251 252 253 254 255

DN0626407

Figure 7 Connector panel CPETS-F

4.2 Flexi BSC


Depending on the maximum number ET interfaces, the BSC3i can be used either with
or without a cabling cabinet.

DN70617303 Id:0900d805804ebded 41
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

4.2.1 Optional cabling cabinet is not used


The optional cabling cabinet is not needed, if the number ET interfaces needed does not
exceed 48.
The E1 and T1 trunk cable connector and in configuration is presented in the following
table.

Pin Signal Colour Remarks


1 R Orange/White Incoming direction
2 T White/Orange
3
4 R Blue/White Outgoing direction
5 T White/Blue
6
7
8

Table 16 E1 and T1 trunk cable connector, pin configuration

The external trunk cable (from the ET panel) and the connector should meet the require-
ments of the UL 1459 standard or the National Electrical Code ANSI/NFPA No.70. The
connector should also meet the requirements of the FCC Part 68
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table
and figure.

Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4


mm2 (type: Filotex Milliflex3 SH G26/2x4)
Cable connec- RJ45 modular connector (8-pole)
tor:

Table 17 Recommended cable type for T1 trunk cables (CNIS)

42 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

IDENTIFICATION
STICKER

CABLE

SLEEVE

MODULAR CONNECTOR

8 1 DN9833994

Figure 8 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table
and figure.

Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross


section 0.4 mm2 (type: Milliflex3 SH G26/4)
Cable connec- RJ45 modular connector plug (8-pole)
tor:

Table 18 Recommended cable type for E1 trunk cables (CNIA)

DN00206525

CONNECTOR 1 2 3 4
Figure 9 RJ45 connector cable (CNIA cable type) with four connectors
The equipping order of the CPETS-E panel at the cabinet in the first deliveries top is pre-
sented in the following table.

DN70617303 Id:0900d805804ebded 43
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

ETC car- From SGC1C- To CPETS-E Front ports in Corresponding external ET


tridge A connector connector CPETS-E panel numbers
position position through this cable
ETC 0 B 19.1A B 00 00,01,02,03 ET368,ET369,ET370,ET371
ETC 0 B 19.1J B 01 04,05,06,07 ET372,ET373,ET374,ET375
ETC 0 B 19.1R B 02 08,09,10,11 ET376,ET377,ET378,ET379
ETC 0 B 19.1Z B 03 12,13,14,15 ET380,ET381,ET382,ET383
ETC 0 B 20.1A B 04 16,17,18,19 ET256,ET257,ET258,ET259
ETC 0 B 20.1J B 05 20,21,22,23 ET260,ET261,ET262,ET263
ETC 0 B 20.1R B 06 24,25,26,27 ET264,ET265,ET266,ET267
ETC 0 B 20.1Z B 07 28,29,30,31 ET268,ET269,ET270,ET271
ETC 0 B 21.1A B 08 32,33,34,35 ET272,ET273,ET274,ET275
ETC 0 B 21.1J B 09 36,37,38,39 ET276,ET277,ET278,ET279
ETC 0 B 21.1R B 10 40,41,42,43 ET280,ET281,ET282,ET283
ETC 0 B 21.1Z B 11 44,45,46,47 ET284,ET285,ET286,ET287

Table 19 Balanced panel at the BSCC cabinet top in first deliveries

The equipping order of the CPETS-E panel at the cabinet in the upgrade deliveries top
is presented in the following table.

ETC car- From GT6C-A To CPETS-E Front ports in Corresponding external ET


tridge connector connector CPETS-E panel numbers
position position through this cable
ETC 0 B 01.1A B 00 00,01,02,03 ET512,ET513,ET514,ET515
ETC 0 B 01.1J B 01 04,05,06,07 ET516,ET517,ET518,ET519
ETC 0 B 01.1R B 02 08,09,10,11 ET520,ET521,ET522,ET523
ETC 0 B 01.1Z B 03 12,13,14,15 ET524,ET525,ET526,ET527
ETC 0 B 02.1A B 04 16,17,18,19 ET528,ET529,ET530,ET531
ETC 0 B 02.1J B 05 20,21,22,23 ET532,ET533,ET534,ET535
ETC 0 B 02.1R B 06 24,25,26,27 ET536,ET537,ET538,ET539
ETC 0 B 02.1Z B 07 28,29,30,31 ET540,ET541,ET542,ET543
ETC 0 B 03.1A B 08 32,33,34,35 ET544,ET545,ET546,ET547
ETC 0 B 03.1J B 09 36,37,38,39 ET548,ET549,ET550,ET551
ETC 0 B 03.1R B 10 40,41,42,43 ET552,ET553,ET554,ET555
ETC 0 B 03.1Z B 11 44,45,46,47 ET556,ET557,ET558,ET559

Table 20 Balanced panel at the BSCC cabinet top in upgrade deliveries

4.2.2 Optional cabling cabinet is used


If more than 48 ET interfaces are needed, the cabling cabinet must be used.

44 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

E1/T1 (PCM) balanced trunk cable panels (CPETS-E and CPETS-F)


The following table shows the connector panels in the cabling cabinet.

Panel Connector panel


number
T00 CPETS-E
0 CPETS-F
1 CPETS-E
2 CPETS-E
3 CPETS-E
4 CPETS-F

Table 21 Balanced connector panels in the cabling cabinet

The cables and the connectors should meet the requirements of the UL 1459 standard
or the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the
requirements of the FCC Part 68.
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table
and figure.

Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4


mm2 (type: Filotex Milliflex3 SH G26/2x4)
Cable connec- RJ45 modular connector (8-pole)
tor:

Table 22 Recommended cable type for T1 trunk cables (CNIS)

IDENTIFICATION
STICKER

CABLE

SLEEVE

MODULAR CONNECTOR

8 1 DN9833994

Figure 10 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table
and figure.

DN70617303 Id:0900d805804ebded 45
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross section


0.4 mm2 (type: Milliflex3 SH G26/4)
Cable connec- RJ45 modular connector plug (8-pole)
tor:

Table 23 Recommended cable type for E1 trunk cables (CNIA)

DN00206525

CONNECTOR 1 2 3 4
Figure 11 RJ45 connector cable (CNIA cable type) with four connectors

Equipping order
The equipping order in the cabling cabinet in the first deliveries presented in the follow-
ing table.

ETC/GTIC From To panel / connector Front ports in Corresponding external ET


index SGC1C-A position balanced panel numbers
connector through this cable
position
ETC 0 B 22.1A Panel 00 / B 00 00,01,02,03 ET256,ET257,ET258,ET259
ETC 0 B 22.1J Panel 00 / B 01 04,05,06,07 ET260,ET261,ET262,ET263
ETC 0 B 22.1R Panel 00 / B 02 08,09,10,11 ET264,ET265,ET266,ET267
ETC 0 B 22.1Z Panel 00 / B 03 12,13,14,15 ET268,ET269,ET270,ET271
ETC 0 B 23.1A Panel 00 / B 04 16,17,18,19 ET304,ET305,ET306,ET307
ETC 0 B 23.1J Panel 00 / B 05 20,21,22,23 ET308,ET309,ET310,ET311
ETC 0 B 23.1R Panel 00 / B 06 24,25,26,27 ET312,ET313,ET314,ET315
ETC 0 B 23.1Z Panel 00 / B 07 28,29,30,31 ET316,ET317,ET318,ET319
ETC 0 B 24.1A Panel 00 / B 08 32,33,34,35 ET320,ET321,ET322,ET323
ETC 0 B 24.1J Panel 00 / B 09 36,37,38,39 ET324,ET325,ET326,ET327
ETC 0 B 24.1R Panel 00 / B 10 40,41,42,43 ET328,ET329,ET330,ET331
ETC 0 B 24.1Z Panel 00 / B 11 44,45,46,47 ET332,ET333,ET334,ET335
ETC 0 B 25.1A Panel 00 / B 12 48,49,50,51 ET336,ET337,ET338,ET339

Table 24 Balanced panels in first deliveries

46 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

ETC/GTIC From To panel / connector Front ports in Corresponding external ET


index SGC1C-A position balanced panel numbers
connector through this cable
position
ETC 0 B 25.1J Panel 00 / B 13 52,53,54,55 ET340,ET341,ET342,ET343
ETC 0 B 25.1R Panel 00 / B 14 56,57,58,59 ET344,ET345,ET346,ET347
ETC 0 B 25.1Z Panel 00 / B 15 60,61,62,63 ET348,ET349,ET350,ET351
ETC 0 B 26.1A Panel 00 / B 16 64,65,66,67 ET352,ET353,ET354,ET355
ETC 0 B 26.1J Panel 00 / B 17 68,69,70,71 ET356,ET357,ET358,ET359
ETC 0 B 26.1R Panel 00 / B 18 72,73,74,75 ET360,ET361,ET362,ET363
ETC 0 B 26.1Z Panel 00 / B 19 76,77,78,79 ET364,ET365,ET366,ET367

ETC 1 B 28.1A Panel 00 / B 20 80,81,82,83 ET640,ET641,ET642,ET643


ETC 1 B 28.1J Panel 00 / B 21 84,85,86,87 ET644,ET645,ET646,ET647
ETC 1 B 28.1R Panel 00 / B 22 88,89,90,91 ET648,ET649,ET650,ET651
ETC 1 B 28.1Z Panel 00 / B 23 92,93,94,95 ET652,ET653,ET654,ET655
ETC 1 B 29.1A Panel 00 / B 24 96,97,98,99 ET624,ET625,ET626,ET627
ETC 1 B 29.1J Panel 00 / B 25 100,101,102,103 ET628,ET629,ET630,ET631
ETC 1 B 29.1R Panel 00 / B 26 104,105,106,107 ET632,ET633,ET634,ET635
ETC 1 B 29.1Z Panel 00 / B 27 108,109,110,111 ET636,ET637,ET638,ET639
ETC 1 B 30.1A Panel 00 / B 28 112,113,114,115 ET512,ET513,ET514,ET515
ETC 1 B 30.1J Panel 00 / B 29 116,117,118,119 ET516,ET517,ET518,ET519
ETC 1 B 30.1R Panel 00 / B 30 120,121,122,123 ET520,ET521,ET522,ET523
ETC 1 B 30.1Z Panel 00 / B 31 124,125,126,127 ET524,ET525,ET526,ET527
ETC 1 B 31.1A Panel 00 / B 32 128,129,130,131 ET528,ET529,ET530,ET531
ETC 1 B 31.1J Panel 00 / B 33 132,133,134,135 ET532,ET533,ET534,ET535
ETC 1 B 31.1R Panel 00 / B 34 136,137,138,139 ET536,ET537,ET538,ET539
ETC 1 B 31.1Z Panel 00 / B 35 140,141,142,143 ET540,ET541,ET542,ET543
ETC 1 B 32.1A Panel 00 / B 36 144,145,146,147 ET544,ET545,ET546,ET547
ETC 1 B 32.1J Panel 00 / B 37 148,149,150,151 ET548,ET549,ET550,ET551
ETC 1 B 32.1R Panel 00 / B 38 152,153,154,155 ET552,ET553,ET554,ET555
ETC 1 B 32.1Z Panel 00 / B 39 156,157,158,159 ET556,ET557,ET558,ET559
ETC 1 B 33.1A Panel 00 / B 40 160,161,162,163 ET560,ET561,ET562,ET563
ETC 1 B 33.1J Panel 00 / B 41 164,165,166,167 ET564,ET565,ET566,ET567
ETC 1 B 33.1R Panel 00 / B 42 168,169,170,171 ET568,ET569,ET570,ET571
ETC 1 B 33.1Z Panel 00 / B 43 172,173,174,175 ET572,ET573,ET574,ET575
ETC 1 B 34.1A Panel 00 / B 44 176,177,178,179 ET576,ET577,ET578,ET579
ETC 1 B 34.1J Panel 00 / B 45 180,181,182,183 ET580,ET581,ET582,ET583

Table 24 Balanced panels in first deliveries (Cont.)

DN70617303 Id:0900d805804ebded 47
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

ETC/GTIC From To panel / connector Front ports in Corresponding external ET


index SGC1C-A position balanced panel numbers
connector through this cable
position
ETC 1 B 34.1R Panel 00 / B 46 184,185,186,187 ET584,ET585,ET586,ET587
ETC 1 B 34.1Z Panel 00 / B 47 188,189,190,191 ET588,ET589,ET590,ET591
ETC 1 B 35.1A Panel 00 / B 48 192,193,194,195 ET592,ET593,ET594,ET595
ETC 1 B 35.1J Panel 00 / B 49 196,197,198,199 ET596,ET597,ET598,ET599
ETC 1 B 35.1R Panel 00 / B 50 200,201,202,203 ET600,ET601,ET602,ET603
ETC 1 B 35.1Z Panel 00 / B 51 204,205,206,207 ET604,ET605,ET606,ET607
ETC 1 B 36.1A Panel 00 / B 52 208,209,210,211 ET608,ET609,ET610,ET611
ETC 1 B 36.1J Panel 00 / B 53 212,213,214,215 ET612,ET613,ET614,ET615
ETC 1 B 36.1R Panel 00 / B 54 216,217,218,219 ET616,ET617,ET618,ET619
ETC 1 B 36.1Z Panel 00 / B 55 220,221,222,223 ET620,ET621,ET622,ET623

GTIC 0 B 10.1A Panel 00 / B 56 224,225,226,227 ET1392,ET1393,ET1394,ET1395


GTIC 0 B 10.1J Panel 00 / B 57 228,229,230,231 ET1396,ET1397,ET1398,ET1399
GTIC 0 B 10.1R Panel 00 / B 58 232,233,234,235 ET1400,ET1401,ET1402,ET1403
GTIC 0 B 10.1Z Panel 00 / B 59 236,237,238,239 ET1404,ET1405,ET1406,ET1407
GTIC 0 B 11.1A Panel 00 / B 60 240,241,242,243 ET1280,ET1281,ET1282,ET1283
GTIC 0 B 11.1J Panel 00 / B 61 244,245,246,247 ET1284,ET1285,ET1286,ET1287
GTIC 0 B 11.1R Panel 00 / B 62 248,249,250,251 ET1288,ET1289,ET1290,ET1291
GTIC 0 B 11.1Z Panel 00 / B 63 252,253,254,255 ET1292,ET1293,ET1294,ET1295

GTIC 1 B 10.1A Panel 01 / B 00 00,01,02,03 ET1920,ET1921,ET1922,ET1923


GTIC 1 B 10.1J Panel 01 / B 01 04,05,06,07 ET1924,ET1925,ET1926,ET1927
GTIC 1 B 10.1R Panel 01 / B 02 08,09,10,11 ET1928,ET1929,ET1930,ET1931
GTIC 1 B 10.1Z Panel 01 / B 03 12,13,14,15 ET1932,ET1933,ET1934,ET1935
GTIC 1 B 11.1A Panel 01 / B 04 16,17,18,19 ET1936,ET1937,ET1938,ET1939
GTIC 1 B 11.1J Panel 01 / B 05 20,21,22,23 ET1940,ET1941,ET1942,ET1943
GTIC 1 B 11.1R Panel 01 / B 06 24,25,26,27 ET1944,ET1945,ET1946,ET1947
GTIC 1 B 11.1Z Panel 01 / B 07 28,29,30,31 ET1948,ET1949,ET1950,ET1951
GTIC 1 B 12.1A Panel 01 / B 08 32,33,34,35 ET1952,ET1953,ET1954,ET1955
GTIC 1 B 12.1J Panel 01 / B 09 36,37,38,39 ET1956,ET1957,ET1958,ET1959
GTIC 1 B 12.1R Panel 01 / B 10 40,41,42,43 ET1960,ET1961,ET1962,ET1963
GTIC 1 B 12.1Z Panel 01 / B 11 44,45,46,47 ET1964,ET1965,ET1966,ET1967

GTIC 1 B 13.1A Panel 02 / B 00 00,01,02,03 ET1968,ET1969,ET1970,ET1971

Table 24 Balanced panels in first deliveries (Cont.)

48 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

ETC/GTIC From To panel / connector Front ports in Corresponding external ET


index SGC1C-A position balanced panel numbers
connector through this cable
position
GTIC 1 B 13.1J Panel 02 / B 01 04,05,06,07 ET1972,ET1973,ET1974,ET1975
GTIC 1 B 13.1R Panel 02 / B 02 08,09,10,11 ET1976,ET1977,ET1978,ET1979
GTIC 1 B 13.1Z Panel 02 / B 03 12,13,14,15 ET1980,ET1981,ET1982,ET1983
GTIC 1 B 14.1A Panel 02 / B 04 16,17,18,19 ET1984,ET1985,ET1986,ET1987
GTIC 1 B 14.1J Panel 02 / B 05 20,21,22,23 ET1988,ET1989,ET1990,ET1991
GTIC 1 B 14.1R Panel 02 / B 06 24,25,26,27 ET1992,ET1993,ET1994,ET1995
GTIC 1 B 14.1Z Panel 02 / B 07 28,29,30,31 ET1996,ET1997,ET1998,ET1999
GTIC 1 B 15.1A Panel 02 / B 08 32,33,34,35 ET2000,ET2001,ET2002,ET2003
GTIC 1 B 15.1J Panel 02 / B 09 36,37,38,39 ET2004,ET2005,ET2006,ET2007
GTIC 1 B 15.1R Panel 02 / B 10 40,41,42,43 ET2008,ET2009,ET2010,ET2011
GTIC 1 B 15.1Z Panel 02 / B 11 44,45,46,47 ET2012,ET2013,ET2014,ET2015

GTIC 1 B 16.1A Panel 03 / B 00 00,01,02,03 ET2016,ET2017,ET2018,ET2019


GTIC 1 B 16.1J Panel 03 / B 01 04,05,06,07 ET2020,ET2021,ET2022,ET2023
GTIC 1 B 16.1R Panel 03 / B 02 08,09,10,11 ET2024,ET2025,ET2026,ET2027
GTIC 1 B 16.1Z Panel 03 / B 03 12,13,14,15 ET2028,ET2029,ET2030,ET2031
GTIC 1 B 17.1A Panel 03 / B 04 16,17,18,19 ET2032,ET2033,ET2034,ET2035
GTIC 1 B 17.1J Panel 03 / B 05 20,21,22,23 ET2036,ET2037,ET2038,ET2039
GTIC 1 B 17.1R Panel 03 / B 06 24,25,26,27 ET2040,ET2041,ET2042,ET2043
GTIC 1 B 17.1Z Panel 03 / B 07 28,29,30,31 ET2044,ET2045,ET2046,ET2047

ETC 2 B 19.1A Panel 03 / B 08 32,33,34,35 ET1136,ET1137,ET1138,ET1139


ETC 2 B 19.1J Panel 03 / B 09 36,37,38,39 ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1R Panel 03 / B 10 40,41,42,43 ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1Z Panel 03 / B 11 44,45,46,47 ET1140,ET1141,ET1142,ET1143

ETC 2 B 20.1A Panel 04 / B 00 00,01,02,03 ET1024,ET1025,ET1026,ET1027


ETC 2 B 20.1J Panel 04 / B 01 04,05,06,07 ET1028,ET1029,ET1030,ET1031
ETC 2 B 20.1R Panel 04 / B 02 08,09,10,11 ET1032,ET1033,ET1034,ET1035
ETC 2 B 20.1Z Panel 04 / B 03 12,13,14,15 ET1036,ET1037,ET1038,ET1039
ETC 2 B 21.1A Panel 04 / B 04 16,17,18,19 ET1040,ET1041,ET1042,ET1043
ETC 2 B 21.1J Panel 04 / B 05 20,21,22,23 ET1044,ET1045,ET1046,ET1047
ETC 2 B 21.1R Panel 04 / B 06 24,25,26,27 ET1048,ET1049,ET1050,ET1051
ETC 2 B 21.1Z Panel 04 / B 07 28,29,30,31 ET1052,ET1053,ET1054,ET1055

Table 24 Balanced panels in first deliveries (Cont.)

DN70617303 Id:0900d805804ebded 49
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

ETC/GTIC From To panel / connector Front ports in Corresponding external ET


index SGC1C-A position balanced panel numbers
connector through this cable
position
ETC 2 B 22.1A Panel 04 / B 08 32,33,34,35 ET1056,ET1057,ET1058,ET1059
ETC 2 B 22.1J Panel 04 / B 09 36,37,38,39 ET1060,ET1061,ET1062,ET1063
ETC 2 B 22.1R Panel 04 / B 10 40,41,42,43 ET1064,ET1065,ET1066,ET1067
ETC 2 B 22.1Z Panel 04 / B 11 44,45,46,47 ET1068,ET1069,ET1070,ET1071
ETC 2 B 23.1A Panel 04 / B 12 48,49,50,51 ET1072,ET1073,ET1074,ET1075
ETC 2 B 23.1J Panel 04 / B 13 52,53,54,55 ET1076,ET1077,ET1078,ET1079
ETC 2 B 23.1R Panel 04 / B 14 56,57,58,59 ET1080,ET1081,ET1082,ET1083
ETC 2 B 23.1Z Panel 04 / B 15 60,61,62,63 ET1084,ET1085,ET1086,ET1087
ETC 2 B 24.1A Panel 04 / B 16 64,65,66,67 ET1088,ET1089,ET1090,ET1091
ETC 2 B 24.1J Panel 04 / B 17 68,69,70,71 ET1092,ET1093,ET1094,ET1095
ETC 2 B 24.1R Panel 04 / B 18 72,73,74,75 ET1096,ET1097,ET1098,ET1099
ETC 2 B 24.1Z Panel 04 / B 19 76,77,78,79 ET1100,ET1101,ET1102,ET1103
ETC 2 B 25.1A Panel 04 / B 20 80,81,82,83 ET1104,ET1105,ET1106,ET1107
ETC 2 B 25.1J Panel 04 / B 21 84,85,86,87 ET1108,ET1109,ET1110,ET1111
ETC 2 B 25.1R Panel 04 / B 22 88,89,90,91 ET1112,ET1113,ET1114,ET1115
ETC 2 B 25.1Z Panel 04 / B 23 92,93,94,95 ET1116,ET1117,ET1118,ET1119
ETC 2 B 26.1A Panel 04 / B 24 96,97,98,99 ET1120,ET1121,ET1122,ET1123
ETC 2 B 26.1J Panel 04 / B 25 100,101,102,103 ET1124,ET1125,ET1126,ET1127
ETC 2 B 26.1R Panel 04 / B 26 104,105,106,107 ET1128,ET1129,ET1130,ET1131
ETC 2 B 26.1Z Panel 04 / B 27 108,109,110,111 ET1132,ET1133,ET1134,ET1135

ETC 3 B 28.1A Panel 04 / B 28 112,113,114,115 ET896,ET897,ET898,ET899


ETC 3 B 28.1J Panel 04 / B 29 116,117,118,119 ET900,ET901,ET902,ET903
ETC 3 B 28.1R Panel 04 / B 30 120,121,122,123 ET904,ET905,ET906,ET907
ETC 3 B 28.1Z Panel 04 / B 31 124,125,126,127 ET908,ET909,ET910,ET911
ETC 3 B 29.1A Panel 04 / B 32 128,129,130,131 ET880,ET881,ET882,ET883
ETC 3 B 29.1J Panel 04 / B 33 132,133,134,135 ET884,ET885,ET886,ET887
ETC 3 B 29.1R Panel 04 / B 34 136,137,138,139 ET888,ET889,ET890,ET891
ETC 3 B 29.1Z Panel 04 / B 35 140,141,142,143 ET892,ET893,ET894,ET895
ETC 3 B 30.1A Panel 04 / B 36 144,145,146,147 ET768,ET769,ET770,ET771
ETC 3 B 30.1J Panel 04 / B 37 148,149,150,151 ET772,ET773,ET774,ET775
ETC 3 B 30.1R Panel 04 / B 38 152,153,154,155 ET776,ET777,ET778,ET779
ETC 3 B 30.1Z Panel 04 / B 39 156,157,158,159 ET780,ET781,ET782,ET783
ETC 3 B 31.1A Panel 04 / B 40 160,161,162,163 ET784,ET785,ET786,ET787

Table 24 Balanced panels in first deliveries (Cont.)

50 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

ETC/GTIC From To panel / connector Front ports in Corresponding external ET


index SGC1C-A position balanced panel numbers
connector through this cable
position
ETC 3 B 31.1J Panel 04 / B 41 164,165,166,167 ET788,ET789,ET790,ET791
ETC 3 B 31.1R Panel 04 / B 42 168,169,170,171 ET792,ET793,ET794,ET795
ETC 3 B 31.1Z Panel 04 / B 43 172,173,174,175 ET796,ET797,ET798,ET799
ETC 3 B 32.1A Panel 04 / B 44 176,177,178,179 ET800,ET801,ET802,ET803
ETC 3 B 32.1J Panel 04 / B 45 180,181,182,183 ET804,ET805,ET806,ET807
ETC 3 B 32.1R Panel 04 / B 46 184,185,186,187 ET808,ET809,ET810,ET811
ETC 3 B 32.1Z Panel 04 / B 47 188,189,190,191 ET812,ET813,ET814,ET815
ETC 3 B 33.1A Panel 04 / B 48 192,193,194,195 ET816,ET817,ET818,ET819
ETC 3 B 33.1J Panel 04 / B 49 196,197,198,199 ET820,ET821,ET822,ET823
ETC 3 B 33.1R Panel 04 / B 50 200,201,202,203 ET824,ET825,ET826,ET827
ETC 3 B 33.1Z Panel 04 / B 51 204,205,206,207 ET828,ET829,ET830,ET831
ETC 3 B 34.1A Panel 04 / B 52 208,209,210,211 ET832,ET833,ET834,ET835
ETC 3 B 34.1J Panel 04 / B 53 212,213,214,215 ET836,ET837,ET838,ET839
ETC 3 B 34.1R Panel 04 / B 54 216,217,218,219 ET840,ET841,ET842,ET843
ETC 3 B 34.1Z Panel 04 / B 55 220,221,222,223 ET844,ET845,ET846,ET847
ETC 3 B 35.1A Panel 04 / B 56 224,225,226,227 ET848,ET849,ET850,ET851
ETC 3 B 35.1J Panel 04 / B 57 228,229,230,231 ET852,ET853,ET854,ET855
ETC 3 B 35.1R Panel 04 / B 58 232,233,234,235 ET856,ET857,ET858,ET859
ETC 3 B 35.1Z Panel 04 / B 59 236,237,238,239 ET860,ET861,ET862,ET863
ETC 3 B 36.1A Panel 04 / B 60 240,241,242,243 ET864,ET865,ET866,ET867
ETC 3 B 36.1J Panel 04 / B 61 244,245,246,247 ET868,ET869,ET870,ET871
ETC 3 B 36.1R Panel 04 / B 62 248,249,250,251 ET872,ET873,ET874,ET875
ETC 3 B 36.1Z Panel 04 / B 63 252,253,254,255 ET876,ET877,ET878,ET879

GTIC 0 B 12.1A Panel T00 / B 00 00,01,02,03 ET1296,ET1297,ET1298,ET1299


GTIC 0 B 12.1J Panel T00 / B 01 04,05,06,07 ET1300,ET1301,ET1302,ET1303
GTIC 0 B 12.1R Panel T00 / B 02 08,09,10,11 ET1304,ET1305,ET1306,ET1307
GTIC 0 B 12.1Z Panel T00 / B 03 12,13,14,15 ET1308,ET1309,ET1310,ET1311
GTIC 0 B 13.1A Panel T00 / B 04 16,17,18,19 ET1312,ET1313,ET1314,ET1315
GTIC 0 B 13.1J Panel T00 / B 05 20,21,22,23 ET1316,ET1317,ET1318,ET1319
GTIC 0 B 13.1R Panel T00 / B 06 24,25,26,27 ET1320,ET1321,ET1322,ET1323
GTIC 0 B 13.1Z Panel T00 / B 07 28,29,30,31 ET1324,ET1325,ET1326,ET1327
GTIC 0 B 14.1A Panel T00 / B 08 32,33,34,35 ET1328,ET1329,ET1330,ET1331
GTIC 0 B 14.1J Panel T00 / B 09 36,37,38,39 ET1332,ET1333,ET1334,ET1335

Table 24 Balanced panels in first deliveries (Cont.)

DN70617303 Id:0900d805804ebded 51
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

ETC/GTIC From To panel / connector Front ports in Corresponding external ET


index SGC1C-A position balanced panel numbers
connector through this cable
position
GTIC 0 B 14.1R Panel T00 / B 10 40,41,42,43 ET1336,ET1337,ET1338,ET1339
GTIC 0 B 14.1Z Panel T00 / B 11 44,45,46,47 ET1340,ET1341,ET1342,ET1343

Table 24 Balanced panels in first deliveries (Cont.)

The equipping order of the connector panels in the cabling cabinet in upgrade deliveries
is presented in the following table.

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ETC 0 B 04.1A Panel 04 / B 61 244,245,246,247 ET560,ET561,ET562,ET563
ETC 0 B 04.1J Panel 04 / B 62 248,249,250,251 ET564,ET565,ET566,ET567
ETC 0 B 04.1R Panel 04 / B 63 252,253,254,255 ET568,ET569,ET570,ET571
ETC 0 B 04.1Z Panel 04 / B 58 232,233,234,235 ET572,ET573,ET574,ET575
ETC 1 B 01.1A Panel 04 / B 59 236,237,238,239 ET576,ET577,ET578,ET579
ETC 1 B 01.1J Panel 04 / B 60 240,241,242,243 ET580,ET581,ET582,ET583
ETC 1 B 01.1R Panel 04 / B 55 220,221,222,223 ET584,ET585,ET586,ET587
ETC 1 B 01.1Z Panel 04 / B 56 224,225,226,227 ET588,ET589,ET590,ET591
ETC 1 B 02.1A Panel 04 / B 57 228,229,230,231 ET592,ET593,ET594,ET595
ETC 1 B 02.1J Panel 04 / B 52 208,209,210,211 ET596,ET597,ET598,ET599
ETC 1 B 02.1R Panel 04 / B 53 212,213,214,215 ET600,ET601,ET602,ET603
ETC 1 B 02.1Z Panel 04 / B 54 216,217,218,219 ET604,ET605,ET606,ET607
ETC 1 B 03.1A Panel 04 / B 49 196,197,198,199 ET608,ET609,ET610,ET611
ETC 1 B 03.1J Panel 04 / B 50 200,201,202,203 ET612,ET613,ET614,ET615
ETC 1 B 03.1R Panel 04 / B 51 204,205,206,207 ET616,ET617,ET618,ET619
ETC 1 B 03.1Z Panel 04 / B 47 188,189,190,191 ET620,ET621,ET622,ET623
ETC 1 B 04.1A Panel 04 / B 48 192,193,194,195 ET624,ET625,ET626,ET627
ETC 1 B 04.1J Panel 04 / B 44 176,177,178,179 ET628,ET629,ET630,ET631
ETC 1 B 04.1R Panel 04 / B 45 180,181,182,183 ET632,ET633,ET634,ET635
ETC 1 B 04.1Z Panel 04 / B 46 184,185,186,187 ET636,ET637,ET638,ET639
GTIC 0 / B 01.1A (GTIC 0)
ETC 5 / B03.1A (ETC 5) Panel 04 / B 41 164,165,166,167 ET904,ET905,ET906,ET907
GTIC 0 / B 01.1J (GTIC 0) /
ETC 5 B03.1J (ETC 5) Panel 04 / B 42 168,169,170,171 ET908,ET909,ET910,ET911
GTIC 0 / B 01.1R (GTIC 0)
ETC 5 / B03.1R (ETC 5) Panel 04 / B 43 172,173,174,175 ET912,ET913,ET914,ET915

Table 25 Balanced panels in upgrade deliveries

52 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
GTIC 0 / B 01.1Z (GTIC 0)
ETC 5 / B03.1Z (ETC 5) Panel 04 / B 38 152,153,154,155 ET916,ET917,ET918,ET919
GTIC 0 / B 02.1A (GTIC 0)
ETC 5 / B04.1A (ETC 5) Panel 04 / B 39 156,157,158,159 ET920,ET921,ET922,ET923
GTIC 0 / B 02.1J (GTIC 0) /
ETC 5 B04.1J (ETC 5) Panel 04 / B 40 160,161,162,163 ET924,ET925,ET926,ET927
GTIC 0 / B 02.1R (GTIC 0)
ETC 5 / B04.1R (ETC 5) Panel 04 / B 35 140,141,142,143 ET928,ET929,ET930,ET931
GTIC 0 / B 02.1Z (GTIC 0)
ETC 5 / B04.1Z (ETC 5) Panel 04 / B 36 144,145,146,147 ET932,ET933,ET934,ET935
GTIC 0 / B 03.1A (GTIC 0)
ETC 5 / B05.1A (ETC 5) Panel 04 / B 37 148,149,150,151 ET936,ET937,ET938,ET939
GTIC 0 / B 03.1J (GTIC 0) /
ETC 5 B05.1J (ETC 5) Panel 04 / B 32 128,129,130,131 ET940,ET941,ET942,ET943
GTIC 0 / B 03.1R (GTIC 0)
ETC 5 / B05.1R (ETC 5) Panel 04 / B 33 132,133,134,135 ET944,ET945,ET946,ET947
GTIC 0 / B 03.1Z (GTIC 0)
ETC 5 / B05.1Z (ETC 5) Panel 04 / B 34 136,137,138,139 ET948,ET949,ET950,ET951
GTIC 0 / B 04.1A (GTIC 0)
ETC 5 / B06.1A (ETC 5) Panel 04 / B 29 116,117,118,119 ET816,ET817,ET818,ET819
GTIC 0 / B 04.1J (GTIC 0) /
ETC 5 B06.1J (ETC 5) Panel 04 / B 30 120,121,122,123 ET820,ET821,ET822,ET823
GTIC 0 / B 04.1R (GTIC 0)
ETC 5 / B06.1R (ETC 5) Panel 04 / B 31 124,125,126,127 ET824,ET825,ET826,ET827
GTIC 0 / B 04.1Z (GTIC 0)
ETC 5 / B06.1Z (ETC 5) Panel 04 / B 26 104,105,106,107 ET828,ET829,ER830,ET831
GTIC 0 / B 05.1A (GTIC 0) ET1072,ET1073,ET1074,ET10
ETC 5 / B07.1A (ETC 5) Panel 04 / B 27 108,109,110,111 75
GTIC 0 / B 05.1J (GTIC 0) / ET1076,ET1077,ET1078,ET10
ETC 5 B07.1J (ETC 5) Panel 04 / B 28 112,113,114,115 79
GTIC 0 / B 05.1R (GTIC 0) ET1080,ET1081,ET1082,ET10
ETC 5 / B07.1R (ETC 5) Panel 04 / B 23 92,93,94,95 83
GTIC 0 / B 05.1Z (GTIC 0) ET1084,ET1085,ET1086,ET10
ETC 5 / B07.1Z (ETC 5) Panel 04 / B 24 96,97,98,99 87
GTIC 0 / B 06.1A (GTIC 0) ET1328,ET1329,ET1330,ET13
ETC 5 / B08.1A (ETC 5) Panel 04 / B 25 100,101,102,103 31
GTIC 0 / B 06.1J (GTIC 0) / ET1332,ET1333,ET1334,ET13
ETC 5 B08.1J (ETC 5) Panel 04 / B 20 80,81,82,83 35
GTIC 0 / B 06.1R (GTIC 0) ET1336,ET1337,ET1338,ET13
ETC 5 / B08.1R (ETC 5) Panel 04 / B 21 84,85,86,87 39
GTIC 0 / B 06.1Z (GTIC 0) ET1340,ET1341,ET1342,ET13
ETC 5 / B08.1Z (ETC 5) Panel 04 / B 22 88,89,90,91 43

Table 25 Balanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d805804ebded 53
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1792,ET1793,ET1794,ET17
GTIC 0 B 07.1A Panel 04 / B 17 68,69,70,71 95
ET1796,ET1797,ET1798,ET17
GTIC 0 B 07.1J Panel 04 / B 18 72,73,74,75 99
ET1800,ET1801,ET1802,ET18
GTIC 0 B 07.1R Panel 04 / B 19 76,77,78,79 03
ET1804,ET1805,ET1806,ET18
GTIC 0 B 07.1Z Panel 04 / B 15 60,61,62,63 07
ET1808,ET1809,ET1810,ET18
GTIC 0 B 08.1A Panel 04 / B 16 64,65,66,67 11
ET1812,ET1813,ET1814,ET18
GTIC 0 B 08.1J Panel 04 / B 12 48,49,50,51 15
ET1816,ET1817,ET1818,ET18
GTIC 0 B 08.1R Panel 04 / B 13 52,53,54,55 19
ET1820,ET1821,ET1822,ET18
GTIC 0 B 08.1Z Panel 04 / B 14 56,57,58,59 23
ET1408,ET1409,ET1410,ET14
GTIC 1 B 01.1A Panel 04 / B 09 36,37,38,39 11
ET1412,ET1413,ET1414,ET14
GTIC 1 B 01.1J Panel 04 / B 10 40,41,42,43 15
ET1416,ET1417,ET1418,ET14
GTIC 1 B 01.1R Panel 04 / B 11 44,45,46,47 19
ET1420,ET1421,ET1422,ET14
GTIC 1 B 01.1Z Panel 04 / B 06 24,25,26,27 23
ET1424,ET1425,ET1426,ET14
GTIC 1 B 02.1A Panel 04 / B 07 28,29,30,31 27
ET1428,ET1429,ET1430,ET14
GTIC 1 B 02.1J Panel 04 / B 08 32,33,34,35 31
ET1432,ET1433,ET1434,ET14
GTIC 1 B 02.1R Panel 04 / B 03 12,13,14,15 35
ET1436,ET1437,ET1438,ET14
GTIC 1 B 02.1Z Panel 04 / B 04 16,17,18,19 39
ET1440,ET1441,ET1442,ET14
GTIC 1 B 03.1A Panel 04 / B 05 20,21,22,23 43
ET1444,ET1445,ET1446,ET14
GTIC 1 B 03.1J Panel 04 / B 00 00,01,02,03 47
ET1448,ET1449,ET1450,ET14
GTIC 1 B 03.1R Panel 04 / B 01 04,05,06,07 51
ET1452,ET1453,ET1454,ET14
GTIC 1 B 03.1Z Panel 04 / B 02 08,09,10,11 55

Table 25 Balanced panels in upgrade deliveries (Cont.)

54 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1456,ET1457,ET1458,ET14
GTIC 1 B 04.1A Panel 03 / B 09 36,37,38,39 59
ET1460,ET1461,ET1462,ET14
GTIC 1 B 04.1J Panel 03 / B 10 40,41,42,43 63
ET1464,ET1465,ET1466,ET14
GTIC 1 B 04.1R Panel 03 / B 11 44,45,46,47 67
ET1468,ET1469,ET1470,ET14
GTIC 1 B 04.1Z Panel 03 / B 06 24,25,26,27 71
ET1472,ET1473,ET1474,ET14
GTIC 1 B 05.1A Panel 03 / B 07 28,29,30,31 75
ET1476,ET1477,ET1478,ET14
GTIC 1 B 05.1J Panel 03 / B 08 32,33,34,35 79
ET1480,ET1481,ET1482,ET14
GTIC 1 B 05.1R Panel 03 / B 03 12,13,14,15 83
ET1484,ET1485,ET1486,ET14
GTIC 1 B 05.1Z Panel 03 / B 04 16,17,18,19 87
ET1488,ET1489,ET1490,ET14
GTIC 1 B 06.1A Panel 03 / B 05 20,21,22,23 91
ET1492,ET1493,ET1494,ET14
GTIC 1 B 06.1J Panel 03 / B 00 00,01,02,03 95
ET1496,ET1497,ET1498,ET14
GTIC 1 B 06.1R Panel 03 / B 01 04,05,06,07 99
ET1500,ET1501,ET1502,ET15
GTIC 1 B 06.1Z Panel 03 / B 02 08,09,10,11 03

ET1504,ET1505,ET1506,ET15
GTIC 1 B 07.1A Panel 02 / B 09 36,37,38,39 07
ET1508,ET1509,ET1510,ET15
GTIC 1 B 07.1J Panel 02 / B 10 40,41,42,43 11
ET1512,ET1513,ET1514,ET15
GTIC 1 B 07.1R Panel 02 / B 11 44,45,46,47 15
ET1516,ET1517,ET1518,ET15
GTIC 1 B 07.1Z Panel 02 / B 06 24,25,26,27 19
ET1520,ET1521,ET1522,ET15
GTIC 1 B 08.1A Panel 02 / B 07 28,29,30,31 23
ET1524,ET1525,ET1526,ET15
GTIC 1 B 08.1J Panel 02 / B 08 32,33,34,35 27
ET1528,ET1529,ET1530,ET15
GTIC 1 B 08.1R Panel 02 / B 03 12,13,14,15 31
ET1532,ET1533,ET1534,ET15
GTIC 1 B 08.1Z Panel 02 / B 04 16,17,18,19 35

Table 25 Balanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d805804ebded 55
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1344,ET1345,ET1346,ET13
ETC 2 B 01.1A Panel 02 / B 05 20,21,22,23 47
ET1348,ET1349,ET1350,ET13
ETC 2 B 01.1J Panel 02 / B 00 00,01,02,03 51
ET1352,ET1353,ET1354,ET13
ETC 2 B 01.1R Panel 02 / B 01 04,05,06,07 55
ET1356,ET1357,ET1358,ET13
ETC 2 B 01.1Z Panel 02 / B 02 08,09,10,11 59

ET1360,ET1361,ET1362,ET13
ETC 2 B 02.1A Panel 01 / B 09 36,37,38,39 63
ET1364,ET1365,ET1366,ET13
ETC 2 B 02.1J Panel 01 / B 10 40,41,42,43 67
ET1368,ET1369,ET1370,ET13
ETC 2 B 02.1R Panel 01 / B 11 44,45,46,47 71
ET1372,ET1373,ET1374,ET13
ETC 2 B 02.1Z Panel 01 / B 06 24,25,26,27 75
ET1376,ET1377,ET1378,ET13
ETC 2 B 03.1A Panel 01 / B 07 28,29,30,31 79
ET1380,ET1381,ET1382,ET13
ETC 2 B 03.1J Panel 01 / B 08 32,33,34,35 83
ET1384,ET1385,ET1386,ET13
ETC 2 B 03.1R Panel 01 / B 03 12,13,14,15 87
ET1388,ET1389,ET1390,ET13
ETC 2 B 03.1Z Panel 01 / B 04 16,17,18,19 91
ET1392,ET1393,ET1394,ET13
ETC 2 B 04.1A Panel 01 / B 05 20,21,22,23 95
ET1396,ET1397,ET1398,ET13
ETC 2 B 04.1J Panel 01 / B 00 00,01,02,03 99
ET1400,ET1401,ET1402,ET14
ETC 2 B 04.1R Panel 01 / B 01 04,05,06,07 03
ET1404,ET1405,ET1406,ET14
ETC 2 B 04.1Z Panel 01 / B 02 08,09,10,11 07

ET1600,ET1601,ET1602,ET16
ETC 2 B 05.1A Panel 00 / B 61 244,245,246,247 03
ET1604,ET1605,ET1606,ET16
ETC 2 B 05.1J Panel 00 / B 62 248,249,250,251 07
ET1608,ET1609,ET1610,ET16
ETC 2 B 05.1R Panel 00 / B 63 252,253,254,255 11
ET1612,ET1613,ET1614,ET16
ETC 2 B 05.1Z Panel 00 / B 58 232,233,234,235 15

Table 25 Balanced panels in upgrade deliveries (Cont.)

56 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1616,ET1617,ET1618,ET16
ETC 2 B 06.1A Panel 00 / B 59 236,237,238,239 19
ET1620,ET1621,ET1622,ET16
ETC 2 B 06.1J Panel 00 / B 60 240,241,242,243 23
ET1624,ET1625,ET1626,ET16
ETC 2 B 06.1R Panel 00 / B 55 220,221,222,223 27
ET1628,ET1629,ET1630,ET16
ETC 2 B 06.1Z Panel 00 / B 56 224,225,226,227 31
ET1632,ET1633,ET1634,ET16
ETC 2 B 07.1A Panel 00 / B 57 228,229,230,231 35
ET1636,ET1637,ET1638,ET16
ETC 2 B 07.1J Panel 00 / B 52 208,209,210,211 39
ET1640,ET1641,ET1642,ET16
ETC 2 B 07.1R Panel 00 / B 53 212,213,214,215 43
ET1644,ET1645,ET1646,ET16
ETC 2 B 07.1Z Panel 00 / B 54 216,217,218,219 47
ET1648,ET1649,ET1650,ET16
ETC 2 B 08.1A Panel 00 / B 49 196,197,198,199 51
ET1652,ET1653,ET1654,ET16
ETC 2 B 08.1J Panel 00 / B 50 200,201,202,203 55
ET1656,ET1657,ET1658,ET16
ETC 2 B 08.1R Panel 00 / B 51 204,205,206,207 59
ET1660,ET1661,ET1662,ET16
ETC 2 B 08.1Z Panel 00 / B 47 188,189,190,191 63
ET1664,ET1665,ET1666,ET16
ETC 3 B 01.1A Panel 00 / B 48 192,193,194,195 67
ET1668,ET1669,ET1670,ET16
ETC 3 B 01.1J Panel 00 / B 44 176,177,178,179 71
ET1672,ET1673,ET1674,ET16
ETC 3 B 01.1R Panel 00 / B 45 180,181,182,183 75
ET1676,ET1677,ET1678,ET16
ETC 3 B 01.1Z Panel 00 / B 46 184,185,186,187 79
ET1680,ET1681,ET1682,ET16
ETC 3 B 02.1A Panel 00 / B 41 164,165,166,167 83
ET1684,ET1685,ET1686,ET16
ETC 3 B 02.1J Panel 00 / B 42 168,169,170,171 87
ET1688,ET1689,ET1690,ET16
ETC 3 B 02.1R Panel 00 / B 43 172,173,174,175 91
ET1692,ET1693,ET1694,ET16
ETC 3 B 02.1Z Panel 00 / B 38 152,153,154,155 95
ET1696,ET1697,ET1698,ET16
ETC 3 B 03.1A Panel 00 / B 39 156,157,158,159 99

Table 25 Balanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d805804ebded 57
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1700,ET1701,ET1702,ET17
ETC 3 B 03.1J Panel 00 / B 40 160,161,162,163 03
ET1704,ET1705,ET1706,ET17
ETC 3 B 03.1R Panel 00 / B 35 140,141,142,143 07
ET1708,ET1709,ET1710,ET17
ETC 3 B 03.1Z Panel 00 / B 36 144,145,146,147 11
ET1712,ET1713,ET1714,ET17
ETC 3 B 04.1A Panel 00 / B 37 148,149,150,151 15
ET1716,ET1717,ET1718,ET17
ETC 3 B 04.1J Panel 00 / B 32 128,129,130,131 19
ET1720,ET1721,ET1722,ET17
ETC 3 B 04.1R Panel 00 / B 33 132,133,134,135 23
ET1724,ET1725,ET1726,ET17
ETC 3 B 04.1Z Panel 00 / B 34 136,137,138,139 27
ET1728,ET1729,ET1730,ET17
ETC 3 B 05.1A Panel 00 / B 29 116,117,118,119 31
ET1732,ET1733,ET1734,ET17
ETC 3 B 05.1J Panel 00 / B 30 120,121,122,123 35
ET1736,ET1737,ET1738,ET17
ETC 3 B 05.1R Panel 00 / B 31 124,125,126,127 39
ET1740,ET1741,ET1742,ET17
ETC 3 B 05.1Z Panel 00 / B 26 104,105,106,107 43
ET1744,ET1745,ET1746,ET17
ETC 3 B 06.1A Panel 00 / B 27 108,109,110,111 47
ET1748,ET1749,ET1750,ET17
ETC 3 B 06.1J Panel 00 / B 28 112,113,114,115 51
ET1752,ET1753,ET1754,ET17
ETC 3 B 06.1R Panel 00 / B 23 92,93,94,95 55
ET1756,ET1757,ET1758,ET17
ETC 3 B 06.1Z Panel 00 / B 24 96,97,98,99 59
ET1760,ET1761,ET1762,ET17
ETC 3 B 07.1A Panel 00 / B 25 100,101,102,103 63
ET1764,ET1765,ET1766,ET17
ETC 3 B 07.1J Panel 00 / B 20 80,81,82,83 67
ET1768,ET1769,ET1770,ET17
ETC 3 B 07.1R Panel 00 / B 21 84,85,86,87 71
ET1772,ET1773,ET1774,ET17
ETC 3 B 07.1Z Panel 00 / B 22 88,89,90,91 75
ET1776,ET1777,ET1778,ET17
ETC 3 B 08.1A Panel 00 / B 17 68,69,70,71 79
ET1780,ET1781,ET1782,ET17
ETC 3 B 08.1J Panel 00 / B 18 72,73,74,75 83

Table 25 Balanced panels in upgrade deliveries (Cont.)

58 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

ETC/GTIC From GT4C-A To panel / connector Front ports in Corresponding external ET


cartridge connector position balanced panel numbers
position through this cable
ET1784,ET1785,ET1786,ET17
ETC 3 B 08.1R Panel 00 / B 19 76,77,78,79 87
ET1788,ET1789,ET1790,ET17
ETC 3 B 08.1Z Panel 00 / B 15 60,61,62,63 91
ET1920,ET1921,ET1922,ET19
ETC 4 B 01.1A Panel 00 / B 16 64,65,66,67 23
ET1924,ET1925,ET1926,ET19
ETC 4 B 01.1J Panel 00 / B 12 48,49,50,51 27
ET1928,ET1929,ET1930,ET19
ETC 4 B 01.1R Panel 00 / B 13 52,53,54,55 31
ET1932,ET1933,ET1934,ET19
ETC 4 B 01.1Z Panel 00 / B 14 56,57,58,59 35
ET1936,ET1937,ET1938,ET19
ETC 4 B 02.1A Panel 00 / B 09 36,37,38,39 39
ET1940,ET1941,ET1942,ET19
ETC 4 B 02.1J Panel 00 / B 10 40,41,42,43 43
ET1944,ET1945,ET1946,ET19
ETC 4 B 02.1R Panel 00 / B 11 44,45,46,47 47
ET1948,ET1949,ET1950,ET19
ETC 4 B 02.1Z Panel 00 / B 06 24,25,26,27 51
ET1952,ET1953,ET1954,ET19
ETC 4 B 03.1A Panel 00 / B 07 28,29,30,31 55
ET1956,ET1957,ET1958,ET19
ETC 4 B 03.1J Panel 00 / B 08 32,33,34,35 59
ET1960,ET1961,ET1962,ET19
ETC 4 B 03.1R Panel 00 / B 03 12,13,14,15 63
ET1964,ET1965,ET1966,ET19
ETC 4 B 03.1Z Panel 00 / B 04 16,17,18,19 67
ET1968,ET1969,ET1970,ET19
ETC 4 B 04.1A Panel 00 / B 05 20,21,22,23 71
ET1972,ET1973,ET1974,ET19
ETC 4 B 04.1J Panel 00 / B 00 00,01,02,03 75
ET1976,ET1977,ET1978,ET19
ETC 4 B 04.1R Panel 00 / B 01 04,05,06,07 79
ET1980,ET1981,ET1982,ET19
ETC 4 B 04.1Z Panel 00 / B 02 08,09,10,11 83

Table 25 Balanced panels in upgrade deliveries (Cont.)

4.3 TCSM3i
Two installation options of the third-generation Transcoder Submultiplexer are available:
the TCSM3i for stand-alone installation option and the TCSM3i for combined
BSC/TCSM installation option. The TCSM3i for stand-alone installation option always

DN70617303 Id:0900d805804ebded 59
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does
not have a cabling cabinet.

4.3.1 TCSM3i for stand-alone installation option


In the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted
to the TCSA cabinet. Balanced cabling panel is default, whereas the unbalanced is
optional and must be ordered separately.

E1/T1 (PCM) balanced trunk cable panel (CPETS-F)


Two large balanced CPETS-F panels are used in the cabling cabinet mounted to the
TCSA cabinet.

Panel Connector panel


number
0 CPETS-F
1 CPBP
2 CPBP
3 CPBP
4 CPETS-F

Table 26 Balanced connector panels for the TCSM3i

The cables and connectors should meet the requirements of the UL 1459 standard or
the National Electrical Code ANSI/NFPA No.70. The connectors should also meet the
requirements of the FCC Part 68.
Recommended cable type for T1 trunk cable (CNIS) is presented in the following table
figure.

Cable type: 4 insulated pairs, twisted, double-shielded, cross section 0.4


mm2 (type: Filotex Milliflex3 SH G26/2x4)
Cable connector: RJ45 modular connector (8-pole)

Table 27 Recommended cable type for T1 trunk cables (CNIS)

60 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

IDENTIFICATION
STICKER

CABLE

SLEEVE

MODULAR CONNECTOR

8 1 DN9833994

Figure 12 Single RJ45 connector cable (CNIS cable type) for T1 trunk cables
Recommended cable type for E1 trunk cables (CNIA) is presented in the following table
and figure.

Cable type: 4x(2x2) insulated pairs, twisted, double-shielded, cross section


0.4 mm2 (type: Milliflex3 SH G26/4)
Cable connector: RJ45 modular connector plug (8-pole)

Table 28 Recommended cable type for E1 trunk cables (CNIA)

DN00206525

CONNECTOR 1 2 3 4
Figure 13 RJ45 connector cable (CNIA cable type) with four connectors

Equipping order
The cabling cabinet is always used with the TCSM3i for stand-alone installation option.
The cabling cabinet and the balanced ET panels are delivered in an optional cabling
cabinet set, because TCSA cabinet is a base for both TCSM3i for stand-alone installa-
tion option and for TCSM3i for combined BSC/TCSM installation option.

DN70617303 Id:0900d805804ebded 61
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

Equipping of ETs proceeds in steps. The equipping order in the cabling cabinet is pre-
sented in the following table.

ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-F panel
connector position through this cable
position
ETC 0 B 01.1A Panel 0 / B 00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 120, 121, 122, 123 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 15
ETC 1 B 04.1Z Panel 0 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C1 slot 16

Table 29 Balanced panels in the cabling cabinet - A-interface

62 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-F panel
connector position through this cable
position
ETC 0 B 03.1A Panel 0 / B32 128, 129, 130, 131 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 132, 133, 134, 135 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 02
ETC 0 B 03.1R Panel 0 / B34 136, 137, 138, 139 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 140, 141, 142, 143 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 144, 145, 146, 147 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 148, 149, 150, 151 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 152, 153, 154, 155 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 156, 157, 158, 159 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 160, 161, 162, 163 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 164, 165, 166, 167 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 168, 169, 170, 171 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 172, 173, 174, 175 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 176, 177, 178, 179 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 180, 181, 182, 183 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 184, 185, 186, 187 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 188, 189, 190, 191 PCM1, 2, 3, 4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 192, 193, 194, 195 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 196, 197, 198, 199 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 200, 201, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 204, 205, 206, 207 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 208, 209, 120, 211 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 212, 213, 214, 215 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 216, 217, 218, 219 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 220, 221, 222, 223 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 224, 225, 226, 227 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 228,229, 230, 231 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 232, 233, 234, 235 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 236, 237, 238, 239 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 240, 241, 242, 243 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 244, 245, 246, 247 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 248, 249, 250, 251 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 252, 253, 254, 255 PCM1, 2, 3, 4 / TR3 in TC2C3 slot 16

ETC 0 B 05.1A Panel 4 / B00 00, 01, 02, 03 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 01

Table 29 Balanced panels in the cabling cabinet - A-interface (Cont.)

DN70617303 Id:0900d805804ebded 63
Issue 1-0
E1/T1 (PCM) balanced trunk cable panels (CPETS-E Connector Panels and External Cables in Flexi BSC
and CPETS-F) and TCSM3i

ETC car- From To panel / con- Front ports in Front ports used for TR3 A-interface
tridge GT4C-A nector CPETS-F panel
connector position through this cable
position
ETC 0 B 05.1J Panel 4 / B01 04, 05, 06, 07 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 08, 09, 10, 11 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 03
ETC 0 B 05.1Z Panel 4 / B03 12, 13, 14, 15 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 16, 17, 18, 19 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 20, 21, 22, 23 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 24, 25, 26, 27 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 28, 29, 30, 31 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 32, 33, 34, 35 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 36, 37, 38, 39 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 40, 41, 42, 43 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 44, 45, 46, 47 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 48, 49, 50, 51 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 52, 53, 54, 55 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 56, 57, 58, 59 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 60, 61, 62, 63 PCM1, 2, 3, 4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 64, 65, 66, 67 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 68, 69, 70, 71 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 72, 73, 74, 75 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 76, 77, 78, 79 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 80, 81, 82, 83 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 84, 85, 86, 87 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 88, 89, 90, 91 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 92, 93, 94, 95 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 96, 97, 98, 99 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 100, 101, 102, 103 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 104, 105, 106, 107 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 108, 109, 110, 111 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 112, 113, 114, 115 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 116, 117, 118, 119 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 120, 121, 122,123 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 124, 125, 126, 127 PCM1, 2, 3, 4 / TR3 in TC2C5 slot 16

Table 29 Balanced panels in the cabling cabinet - A-interface (Cont.)

64 Id:0900d805804ebded DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1/T1 (PCM) balanced trunk cable panels (CPETS-E
and TCSM3i and CPETS-F)

From car- TR3 unit slot From ET16 slot and ET panel / front ports through
tridge connector position this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 128, 129, 130, 131
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 132, 133, 134, 135
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 136, 137, 138, 139
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 140, 141, 142, 143
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 144, 145, 146, 147
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 148, 149, 150, 151
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 152, 153, 154, 155
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 156, 157, 158, 159
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 160, 161, 162, 163
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 164, 165, 166, 167
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 168, 169, 170, 171
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 172, 173, 174, 175
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 176, 177, 178, 179
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 180, 181, 182, 183
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 184, 185, 186, 187
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 188, 189, 190, 191
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 192, 193, 194, 195
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 196, 197, 198, 199
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 200, 201, 202, 203
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 204, 205, 206, 207
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 208, 209, 210, 211
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 212, 213, 214, 215
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 216, 217, 218, 219
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 220, 221, 222, 223
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C cartridge
is used for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for
transcoder connections of two BSCs (one half of the TC2C cartridge for one BSC and the
other half for the other BSC).

Table 30 Balanced panels in the cabling cabinet - Ater-interface

4.3.2 TCSM3i for combined BSC/TCSM installation option


The cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined
BSC/TCSM installation option. Instead, the optical cabling from the front connectors of
the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.

DN70617303 Id:0900d805804ebded 65
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

5 E1 (PCM) unbalanced trunk cable panels


(CPETC-E and CPETC-F)

5.1 Connector panels CPETC-E and CPETC-F with D37 con-


nector packs
The small CPETC-E connector panel and the large CPETC-F connector panels are
used for E1 (PCM) unbalanced trunk cables.
Cabling of the CPETC-E panels is described in the cabling lists delivered in the Site Doc-
uments binder. The CPETC-E is installed at the BSCC cabinet top (one panel) or in the
optional cabling cabinet (a total of four small panels, because there are three small
panels in the cabinet and an additional small panel at the cabling cabinet top in first
deliveries). The installation of the connector panel at the equipment cabinet top requires
the use of Roof adapter (RACP) and the installation of the connector panel at the cabling
cabinet top in first deliveries requires the use of Roof adapter 2 (RACP2).
For details of the panel, see figure Connector panel CPETC-E.

00 01

02 03

04 05

06 07

08 09

10 11

DN05160363 CPETC-E

00 01 02 03

8 7 6 5 4 3 2 1

Tx Rx Tx Rx Tx Rx Tx Rx
Figure 14 CPETC-E panel
Cabling of the CPETC-F panels is described in the cabling lists delivered in the Site Doc-
uments binder. The CPETC-F is installed in the optional cabling cabinet (two panels).
For more information on the panel, see the following figure.

66 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

CPETC-F

00 01 02 03 04 05 06 07

08 09 10 11 12 13 14 15

16 17 18 19 20 21 22 23

24 25 26 27 28 29 30 31

32 33 34 35 36 37 38 39

40 41 42 43 44 45 46 47

48 49 50 51 52 53 54 55

56 57 58 59 60 61 62 63

DN0626419

Figure 15 CPETC-F panel

5.2 Flexi BSC


Depending on the maximum number ET interfaces, the Flexi BSC can be used either
with or without an optional cabling cabinet.

DN70617303 Id:0900d8058049ecb0 67
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

5.2.1 Optional cabling cabinet is not used


The optional cabling cabinet is not needed, if the number ET interfaces needed does not
exceed 48.
The unbalanced (asymmetrical) PCM trunk circuit interfaces are cabled by using coaxial
cable connectors from the CPETC-E panels, and the recommended cable type for E1
coaxial trunk cable is CPRD. See the following table and figure.

Cable type: Filotex ET 267 380


Cable connector: D37 connector body, type FCI DC8W8PA00; or ITT Cannon
DCM-8W8P-A197
Coaxial inserts: Rosenberger 55S101-302E2; IMS 307.23.2415.421

DN99257685

A1 A8
Figure 16 CPRD cable assembly (panel end connector mounted)
The equipping order of the CPETC-E panel in first deliveries is presented in the following
table.

ETC car- From SGC1C- To Multicoaxial front Corresponding external ET


tridge A connector CPETC-E ports in CPETC-E numbers
position connector panel through this
position cable
ETC 0 B 19.1A B 00 00 (4*ET) ET368,ET369,ET370,ET371
ETC 0 B 19.1J B 01 01 (4*ET) ET372,ET373,ET374,ET375
ETC 0 B 19.1R B 02 02 (4*ET) ET376,ET377,ET378,ET379
ETC 0 B 19.1Z B 03 03 (4*ET) ET380,ET381,ET382,ET383
ETC 0 B 20.1A B 04 04 (4*ET) ET256,ET257,ET258,ET259
ETC 0 B 20.1J B 05 05 (4*ET) ET260,ET261,ET262,ET263
ETC 0 B 20.1R B 06 06 (4*ET) ET264,ET265,ET266,ET267
ETC 0 B 20.1Z B 07 07 (4*ET) ET268,ET269,ET270,ET271

Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries

68 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC car- From SGC1C- To Multicoaxial front Corresponding external ET


tridge A connector CPETC-E ports in CPETC-E numbers
position connector panel through this
position cable
ETC 0 B 21.1A B 08 08 (4*ET) ET272,ET273,ET274,ET275
ETC 0 B 21.1J B 09 09 (4*ET) ET276,ET277,ET278,ET279
ETC 0 B 21.1R B 10 10 (4*ET) ET280,ET281,ET282,ET283
ETC 0 B 21.1Z B 11 11 (4*ET) ET284,ET285,ET286,ET287

Table 31 Unbalanced panel at the BSCC cabinet top in first deliveries (Cont.)

The equipping order of the CPETC-E panel in upgrade deliveries is presented in the fol-
lowing table.

ETC car- From GT6C-A To CPETC- Multicoaxial Corresponding external ET


tridge connector E connec- front ports in numbers
position tor position CPETC-E panel
through this
cable
ETC 0 B 01.1A B 00 00 (4*ET) ET512,ET513,ET514,ET515
ETC 0 B 01.1J B 01 01 (4*ET) ET516,ET517,ET518,ET519
ETC 0 B 01.1R B 02 02 (4*ET) ET520,ET521,ET522,ET523
ETC 0 B 01.1Z B 03 03 (4*ET) ET524,ET525,ET526,ET527
ETC 0 B 02.1A B 04 04 (4*ET) ET528,ET529,ET530,ET531
ETC 0 B 02.1J B 05 05 (4*ET) ET532,ET533,ET534,ET535
ETC 0 B 02.1R B 06 06 (4*ET) ET536,ET537,ET538,ET539
ETC 0 B 02.1Z B 07 07 (4*ET) ET540,ET541,ET542,ET543
ETC 0 B 03.1A B 08 08 (4*ET) ET544,ET545,ET546,ET547
ETC 0 B 03.1J B 09 09 (4*ET) ET548,ET549,ET550,ET551
ETC 0 B 03.1R B 10 10 (4*ET) ET552,ET553,ET554,ET555
ETC 0 B 03.1Z B 11 11 (4*ET) ET556,ET557,ET558,ET559

Table 32 Unbalanced panel at the BSCC cabinet top in upgrade deliveries

5.2.2 Optional cabling cabinet is used


If more than 48 ET interfaces are needed, the cabling cabinet must be used with the
Flexi BSC.

E1 (PCM) unbalanced trunk cable panels (CPETC-E and CPETC-F)


The following table shows the connector panels in the cabling cabinet.

Panel number Connector panel


T00 CPETC-E

Table 33 Unbalanced connector panels for the Flexi BSC

DN70617303 Id:0900d8058049ecb0 69
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

Panel number Connector panel


0 CPETC-F
1 CPETC-E
2 CPETC-E
3 CPETC-E
4 CPETC-F

Table 33 Unbalanced connector panels for the Flexi BSC (Cont.)

The unbalanced (asymmetrical) PCM trunk circuit interfaces are cabled by using coaxial
cable connectors from the CPETC-E or CPETC-F panels. The recommended cable type
for E1 coaxial trunk cables is CPRD. See the following table and figure.

Cable type Filotex ET 267 380


Cable connector D37 connector body, type FCI DC8W8PA00; or ITT Cannon
DCM-8W8P-A197
Coaxial inserts Rosenberger 55S101-302E2; IMS 307.23.2415.421

Table 34 Recommended cable type for E1 coaxial trunk cables (CPRD)

DN99257685

A1 A8
Figure 17 CPRD cable assembly (panel end connector mounted)

Equipping order
The equipping order in the cabling cabinet in first deliveries is presented in the following
table.

70 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC/GTIC From SGC1C- To panel / connector Multicoaxial Corresponding external ET


index A connector position front ports in numbers
position unbalanced
panel through
this cable
ETC 0 B 22.1A Panel 00 / B 00 00 (4*ET) ET256,ET257,ET258,ET259
ETC 0 B 22.1J Panel 00 / B 01 01 (4*ET) ET260,ET261,ET262,ET263
ETC 0 B 22.1R Panel 00 / B 02 02 (4*ET) ET264,ET265,ET266,ET267
ETC 0 B 22.1Z Panel 00 / B 03 03 (4*ET) ET268,ET269,ET270,ET271
ETC 0 B 23.1A Panel 00 / B 04 04 (4*ET) ET304,ET305,ET306,ET307
ETC 0 B 23.1J Panel 00 / B 05 05 (4*ET) ET308,ET309,ET310,ET311
ETC 0 B 23.1R Panel 00 / B 06 06 (4*ET) ET312,ET313,ET314,ET315
ETC 0 B 23.1Z Panel 00 / B 07 07 (4*ET) ET316,ET317,ET318,ET319
ETC 0 B 24.1A Panel 00 / B 08 08 (4*ET) ET320,ET321,ET322,ET323
ETC 0 B 24.1J Panel 00 / B 09 09 (4*ET) ET324,ET325,ET326,ET327
ETC 0 B 24.1R Panel 00 / B 10 10 (4*ET) ET328,ET329,ET330,ET331
ETC 0 B 24.1Z Panel 00 / B 11 11 (4*ET) ET332,ET333,ET334,ET335
ETC 0 B 25.1A Panel 00 / B 12 12 (4*ET) ET336,ET337,ET338,ET339
ETC 0 B 25.1J Panel 00 / B 13 13 (4*ET) ET340,ET341,ET342,ET343
ETC 0 B 25.1R Panel 00 / B 14 14 (4*ET) ET344,ET345,ET346,ET347
ETC 0 B 25.1Z Panel 00 / B 15 15 (4*ET) ET348,ET349,ET350,ET351
ETC 0 B 26.1A Panel 00 / B 16 16 (4*ET) ET352,ET353,ET354,ET355
ETC 0 B 26.1J Panel 00 / B 17 17 (4*ET) ET356,ET357,ET358,ET359
ETC 0 B 26.1R Panel 00 / B 18 18 (4*ET) ET360,ET361,ET362,ET363
ETC 0 B 26.1Z Panel 00 / B 19 19 (4*ET) ET364,ET365,ET366,ET367

ETC 1 B 28.1A Panel 00 / B 20 20 (4*ET) ET640,ET641,ET642,ET643


ETC 1 B 28.1J Panel 00 / B 21 21 (4*ET) ET644,ET645,ET646,ET647
ETC 1 B 28.1R Panel 00 / B 22 22 (4*ET) ET648,ET649,ET650,ET651
ETC 1 B 28.1Z Panel 00 / B 23 23 (4*ET) ET652,ET653,ET654,ET655
ETC 1 B 29.1A Panel 00 / B 24 24 (4*ET) ET624,ET625,ET626,ET627
ETC 1 B 29.1J Panel 00 / B 25 25 (4*ET) ET628,ET629,ET630,ET631
ETC 1 B 29.1R Panel 00 / B 26 26 (4*ET) ET632,ET633,ET634,ET635
ETC 1 B 29.1Z Panel 00 / B 27 27 (4*ET) ET636,ET637,ET638,ET639
ETC 1 B 30.1A Panel 00 / B 28 28 (4*ET) ET512,ET513,ET514,ET515
ETC 1 B 30.1J Panel 00 / B 29 29 (4*ET) ET516,ET517,ET518,ET519
ETC 1 B 30.1R Panel 00 / B 30 30 (4*ET) ET520,ET521,ET522,ET523
ETC 1 B 30.1Z Panel 00 / B 31 31 (4*ET) ET524,ET525,ET526,ET527

Table 35 Unbalanced panels in first deliveries

DN70617303 Id:0900d8058049ecb0 71
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

ETC/GTIC From SGC1C- To panel / connector Multicoaxial Corresponding external ET


index A connector position front ports in numbers
position unbalanced
panel through
this cable
ETC 1 B 31.1A Panel 00 / B 32 32 (4*ET) ET528,ET529,ET530,ET531
ETC 1 B 31.1J Panel 00 / B 33 33 (4*ET) ET532,ET533,ET534,ET535
ETC 1 B 31.1R Panel 00 / B 34 34 (4*ET) ET536,ET537,ET538,ET539
ETC 1 B 31.1Z Panel 00 / B 35 35 (4*ET) ET540,ET541,ET542,ET543
ETC 1 B 32.1A Panel 00 / B 36 36 (4*ET) ET544,ET545,ET546,ET547
ETC 1 B 32.1J Panel 00 / B 37 37 (4*ET) ET548,ET549,ET550,ET551
ETC 1 B 32.1R Panel 00 / B 38 38 (4*ET) ET552,ET553,ET554,ET555
ETC 1 B 32.1Z Panel 00 / B 39 39 (4*ET) ET556,ET557,ET558,ET559
ETC 1 B 33.1A Panel 00 / B 40 40 (4*ET) ET560,ET561,ET562,ET563
ETC 1 B 33.1J Panel 00 / B 41 41 (4*ET) ET564,ET565,ET566,ET567
ETC 1 B 33.1R Panel 00 / B 42 42 (4*ET) ET568,ET569,ET570,ET571
ETC 1 B 33.1Z Panel 00 / B 43 43 (4*ET) ET572,ET573,ET574,ET575
ETC 1 B 34.1A Panel 00 / B 44 44 (4*ET) ET576,ET577,ET578,ET579
ETC 1 B 34.1J Panel 00 / B 45 45 (4*ET) ET580,ET581,ET582,ET583
ETC 1 B 34.1R Panel 00 / B 46 46 (4*ET) ET584,ET585,ET586,ET587
ETC 1 B 34.1Z Panel 00 / B 47 47 (4*ET) ET588,ET589,ET590,ET591
ETC 1 B 35.1A Panel 00 / B 48 48 (4*ET) ET592,ET593,ET594,ET595
ETC 1 B 35.1J Panel 00 / B 49 49 (4*ET) ET596,ET597,ET598,ET599
ETC 1 B 35.1R Panel 00 / B 50 50 (4*ET) ET600,ET601,ET602,ET603
ETC 1 B 35.1Z Panel 00 / B 51 51 (4*ET) ET604,ET605,ET606,ET607
ETC 1 B 36.1A Panel 00 / B 52 52 (4*ET) ET608,ET609,ET610,ET611
ETC 1 B 36.1J Panel 00 / B 53 53 (4*ET) ET612,ET613,ET614,ET615
ETC 1 B 36.1R Panel 00 / B 54 54 (4*ET) ET616,ET617,ET618,ET619
ETC 1 B 36.1Z Panel 00 / B 55 55 (4*ET) ET620,ET621,ET622,ET623

GTIC 0 B 10.1A Panel 00 / B 56 56 (4*ET) ET1392,ET1393,ET1394,ET1395


GTIC 0 B 10.1J Panel 00 / B 57 57 (4*ET) ET1396,ET1397,ET1398,ET1399
GTIC 0 B 10.1R Panel 00 / B 58 58 (4*ET) ET1400,ET1401,ET1402,ET1403
GTIC 0 B 10.1Z Panel 00 / B 59 59 (4*ET) ET1404,ET1405,ET1406,ET1407
GTIC 0 B 11.1A Panel 00 / B 60 60 (4*ET) ET1280,ET1281,ET1282,ET1283
GTIC 0 B 11.1J Panel 00 / B 61 61 (4*ET) ET1284,ET1285,ET1286,ET1287
GTIC 0 B 11.1R Panel 00 / B 62 62 (4*ET) ET1288,ET1289,ET1290,ET1291
GTIC 0 B 11.1Z Panel 00 / B 63 63 (4*ET) ET1292,ET1293,ET1294,ET1295

Table 35 Unbalanced panels in first deliveries (Cont.)

72 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC/GTIC From SGC1C- To panel / connector Multicoaxial Corresponding external ET


index A connector position front ports in numbers
position unbalanced
panel through
this cable
GTIC 1 B 10.1A Panel 01 / B 00 00 (4*ET) ET1920,ET1921,ET1922,ET1923
GTIC 1 B 10.1J Panel 01 / B 01 01 (4*ET) ET1924,ET1925,ET1926,ET1927
GTIC 1 B 10.1R Panel 01 / B 02 02 (4*ET) ET1928,ET1929,ET1930,ET1931
GTIC 1 B 10.1Z Panel 01 / B 03 03 (4*ET) ET1932,ET1933,ET1934,ET1935
GTIC 1 B 11.1A Panel 01 / B 04 04 (4*ET) ET1936,ET1937,ET1938,ET1939
GTIC 1 B 11.1J Panel 01 / B 05 05 (4*ET) ET1940,ET1941,ET1942,ET1943
GTIC 1 B 11.1R Panel 01 / B 06 06 (4*ET) ET1944,ET1945,ET1946,ET1947
GTIC 1 B 11.1Z Panel 01 / B 07 07 (4*ET) ET1948,ET1949,ET1950,ET1951
GTIC 1 B 12.1A Panel 01 / B 08 08 (4*ET) ET1952,ET1953,ET1954,ET1955
GTIC 1 B 12.1J Panel 01 / B 09 09 (4*ET) ET1956,ET1957,ET1958,ET1959
GTIC 1 B 12.1R Panel 01 / B 10 10 (4*ET) ET1960,ET1961,ET1962,ET1963
GTIC 1 B 12.1Z Panel 01 / B 11 11 (4*ET) ET1964,ET1965,ET1966,ET1967

GTIC 1 B 13.1A Panel 02 / B 00 00 (4*ET) ET1968,ET1969,ET1970,ET1971


GTIC 1 B 13.1J Panel 02 / B 01 01 (4*ET) ET1972,ET1973,ET1974,ET1975
GTIC 1 B 13.1R Panel 02 / B 02 02 (4*ET) ET1976,ET1977,ET1978,ET1979
GTIC 1 B 13.1Z Panel 02 / B 03 03 (4*ET) ET1980,ET1981,ET1982,ET1983
GTIC 1 B 14.1A Panel 02 / B 04 04 (4*ET) ET1984,ET1985,ET1986,ET1987
GTIC 1 B 14.1J Panel 02 / B 05 05 (4*ET) ET1988,ET1989,ET1990,ET1991
GTIC 1 B 14.1R Panel 02 / B 06 06 (4*ET) ET1992,ET1993,ET1994,ET1995
GTIC 1 B 14.1Z Panel 02 / B 07 07 (4*ET) ET1996,ET1997,ET1998,ET1999
GTIC 1 B 15.1A Panel 02 / B 08 08 (4*ET) ET2000,ET2001,ET2002,ET2003
GTIC 1 B 15.1J Panel 02 / B 09 09 (4*ET) ET2004,ET2005,ET2006,ET2007
GTIC 1 B 15.1R Panel 02 / B 10 10 (4*ET) ET2008,ET2009,ET2010,ET2011
GTIC 1 B 15.1Z Panel 02 / B 11 11 (4*ET) ET2012,ET2013,ET2014,ET2015

GTIC 1 B 16.1A Panel 03 / B 00 00 (4*ET) ET2016,ET2017,ET2018,ET2019


GTIC 1 B 16.1J Panel 03 / B 01 01 (4*ET) ET2020,ET2021,ET2022,ET2023
GTIC 1 B 16.1R Panel 03 / B 02 02 (4*ET) ET2024,ET2025,ET2026,ET2027
GTIC 1 B 16.1Z Panel 03 / B 03 03 (4*ET) ET2028,ET2029,ET2030,ET2031
GTIC 1 B 17.1A Panel 03 / B 04 04 (4*ET) ET2032,ET2033,ET2034,ET2035
GTIC 1 B 17.1J Panel 03 / B 05 05 (4*ET) ET2036,ET2037,ET2038,ET2039
GTIC 1 B 17.1R Panel 03 / B 06 06 (4*ET) ET2040,ET2041,ET2042,ET2043
GTIC 1 B 17.1Z Panel 03 / B 07 07 (4*ET) ET2044,ET2045,ET2046,ET2047

Table 35 Unbalanced panels in first deliveries (Cont.)

DN70617303 Id:0900d8058049ecb0 73
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

ETC/GTIC From SGC1C- To panel / connector Multicoaxial Corresponding external ET


index A connector position front ports in numbers
position unbalanced
panel through
this cable

ETC 2 B 19.1A Panel 03 / B 08 08 (4*ET) ET1136,ET1137,ET1138,ET1139


ETC 2 B 19.1J Panel 03 / B 09 09 (4*ET) ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1R Panel 03 / B 10 10 (4*ET) ET1140,ET1141,ET1142,ET1143
ETC 2 B 19.1Z Panel 03 / B 11 11 (4*ET) ET1140,ET1141,ET1142,ET1143

ETC 2 B 20.1A Panel 04 / B 00 00 (4*ET) ET1024,ET1025,ET1026,ET1027


ETC 2 B 20.1J Panel 04 / B 01 01 (4*ET) ET1028,ET1029,ET1030,ET1031
ETC 2 B 20.1R Panel 04 / B 02 02 (4*ET) ET1032,ET1033,ET1034,ET1035
ETC 2 B 20.1Z Panel 04 / B 03 03 (4*ET) ET1036,ET1037,ET1038,ET1039
ETC 2 B 21.1A Panel 04 / B 04 04 (4*ET) ET1040,ET1041,ET1042,ET1043
ETC 2 B 21.1J Panel 04 / B 05 05 (4*ET) ET1044,ET1045,ET1046,ET1047
ETC 2 B 21.1R Panel 04 / B 06 06 (4*ET) ET1048,ET1049,ET1050,ET1051
ETC 2 B 21.1Z Panel 04 / B 07 07 (4*ET) ET1052,ET1053,ET1054,ET1055
ETC 2 B 22.1A Panel 04 / B 08 08 (4*ET) ET1056,ET1057,ET1058,ET1059
ETC 2 B 22.1J Panel 04 / B 09 09 (4*ET) ET1060,ET1061,ET1062,ET1063
ETC 2 B 22.1R Panel 04 / B 10 10 (4*ET) ET1064,ET1065,ET1066,ET1067
ETC 2 B 22.1Z Panel 04 / B 11 11 (4*ET) ET1068,ET1069,ET1070,ET1071
ETC 2 B 23.1A Panel 04 / B 12 12 (4*ET) ET1072,ET1073,ET1074,ET1075
ETC 2 B 23.1J Panel 04 / B 13 13 (4*ET) ET1076,ET1077,ET1078,ET1079
ETC 2 B 23.1R Panel 04 / B 14 14 (4*ET) ET1080,ET1081,ET1082,ET1083
ETC 2 B 23.1Z Panel 04 / B 15 15 (4*ET) ET1084,ET1085,ET1086,ET1087
ETC 2 B 24.1A Panel 04 / B 16 16 (4*ET) ET1088,ET1089,ET1090,ET1091
ETC 2 B 24.1J Panel 04 / B 17 17 (4*ET) ET1092,ET1093,ET1094,ET1095
ETC 2 B 24.1R Panel 04 / B 18 18 (4*ET) ET1096,ET1097,ET1098,ET1099
ETC 2 B 24.1Z Panel 04 / B 19 19 (4*ET) ET1100,ET1101,ET1102,ET1103
ETC 2 B 25.1A Panel 04 / B 20 20 (4*ET) ET1104,ET1105,ET1106,ET1107
ETC 2 B 25.1J Panel 04 / B 21 21 (4*ET) ET1108,ET1109,ET1110,ET1111
ETC 2 B 25.1R Panel 04 / B 22 22 (4*ET) ET1112,ET1113,ET1114,ET1115
ETC 2 B 25.1Z Panel 04 / B 23 23 (4*ET) ET1116,ET1117,ET1118,ET1119
ETC 2 B 26.1A Panel 04 / B 24 24 (4*ET) ET1120,ET1121,ET1122,ET1123
ETC 2 B 26.1J Panel 04 / B 25 25 (4*ET) ET1124,ET1125,ET1126,ET1127
ETC 2 B 26.1R Panel 04 / B 26 26 (4*ET) ET1128,ET1129,ET1130,ET1131
ETC 2 B 26.1Z Panel 04 / B 27 27 (4*ET) ET1132,ET1133,ET1134,ET1135

Table 35 Unbalanced panels in first deliveries (Cont.)

74 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC/GTIC From SGC1C- To panel / connector Multicoaxial Corresponding external ET


index A connector position front ports in numbers
position unbalanced
panel through
this cable

ETC 3 B 28.1A Panel 04 / B 28 28 (4*ET) ET896,ET897,ET898,ET899


ETC 3 B 28.1J Panel 04 / B 29 29 (4*ET) ET900,ET901,ET902,ET903
ETC 3 B 28.1R Panel 04 / B 30 30 (4*ET) ET904,ET905,ET906,ET907
ETC 3 B 28.1Z Panel 04 / B 31 31 (4*ET) ET908,ET909,ET910,ET911
ETC 3 B 29.1A Panel 04 / B 32 32 (4*ET) ET880,ET881,ET882,ET883
ETC 3 B 29.1J Panel 04 / B 33 33 (4*ET) ET884,ET885,ET886,ET887
ETC 3 B 29.1R Panel 04 / B 34 34 (4*ET) ET888,ET889,ET890,ET891
ETC 3 B 29.1Z Panel 04 / B 35 35 (4*ET) ET892,ET893,ET894,ET895
ETC 3 B 30.1A Panel 04 / B 36 36 (4*ET) ET768,ET769,ET770,ET771
ETC 3 B 30.1J Panel 04 / B 37 37 (4*ET) ET772,ET773,ET774,ET775
ETC 3 B 30.1R Panel 04 / B 38 38 (4*ET) ET776,ET777,ET778,ET779
ETC 3 B 30.1Z Panel 04 / B 39 39 (4*ET) ET780,ET781,ET782,ET783
ETC 3 B 31.1A Panel 04 / B 40 40 (4*ET) ET784,ET785,ET786,ET787
ETC 3 B 31.1J Panel 04 / B 41 41 (4*ET) ET788,ET789,ET790,ET791
ETC 3 B 31.1R Panel 04 / B 42 42 (4*ET) ET792,ET793,ET794,ET795
ETC 3 B 31.1Z Panel 04 / B 43 43 (4*ET) ET796,ET797,ET798,ET799
ETC 3 B 32.1A Panel 04 / B 44 44 (4*ET) ET800,ET801,ET802,ET803
ETC 3 B 32.1J Panel 04 / B 45 45 (4*ET) ET804,ET805,ET806,ET807
ETC 3 B 32.1R Panel 04 / B 46 46 (4*ET) ET808,ET809,ET810,ET811
ETC 3 B 32.1Z Panel 04 / B 47 47 (4*ET) ET812,ET813,ET814,ET815
ETC 3 B 33.1A Panel 04 / B 48 48 (4*ET) ET816,ET817,ET818,ET819
ETC 3 B 33.1J Panel 04 / B 49 49 (4*ET) ET820,ET821,ET822,ET823
ETC 3 B 33.1R Panel 04 / B 50 50 (4*ET) ET824,ET825,ET826,ET827
ETC 3 B 33.1Z Panel 04 / B 51 51 (4*ET) ET828,ET829,ET830,ET831
ETC 3 B 34.1A Panel 04 / B 52 52 (4*ET) ET832,ET833,ET834,ET835
ETC 3 B 34.1J Panel 04 / B 53 53 (4*ET) ET836,ET837,ET838,ET839
ETC 3 B 34.1R Panel 04 / B 54 54 (4*ET) ET840,ET841,ET842,ET843
ETC 3 B 34.1Z Panel 04 / B 55 55 (4*ET) ET844,ET845,ET846,ET847
ETC 3 B 35.1A Panel 04 / B 56 56 (4*ET) ET848,ET849,ET850,ET851
ETC 3 B 35.1J Panel 04 / B 57 57 (4*ET) ET852,ET853,ET854,ET855
ETC 3 B 35.1R Panel 04 / B 58 58 (4*ET) ET856,ET857,ET858,ET859
ETC 3 B 35.1Z Panel 04 / B 59 59 (4*ET) ET860,ET861,ET862,ET863
ETC 3 B 36.1A Panel 04 / B 60 60 (4*ET) ET864,ET865,ET866,ET867

Table 35 Unbalanced panels in first deliveries (Cont.)

DN70617303 Id:0900d8058049ecb0 75
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

ETC/GTIC From SGC1C- To panel / connector Multicoaxial Corresponding external ET


index A connector position front ports in numbers
position unbalanced
panel through
this cable
ETC 3 B 36.1J Panel 04 / B 61 61 (4*ET) ET868,ET869,ET870,ET871
ETC 3 B 36.1R Panel 04 / B 62 62 (4*ET) ET872,ET873,ET874,ET875
ETC 3 B 36.1Z Panel 04 / B 63 63 (4*ET) ET876,ET877,ET878,ET879

GTIC 0 B 12.1A Panel T00 / B 00 00 (4*ET) ET1296,ET1297,ET1298,ET1299


GTIC 0 B 12.1J Panel T00 / B 01 01 (4*ET) ET1300,ET1301,ET1302,ET1303
GTIC 0 B 12.1R Panel T00 / B 02 02 (4*ET) ET1304,ET1305,ET1306,ET1307
GTIC 0 B 12.1Z Panel T00 / B 03 03 (4*ET) ET1308,ET1309,ET1310,ET1311
GTIC 0 B 13.1A Panel T00 / B 04 04 (4*ET) ET1312,ET1313,ET1314,ET1315
GTIC 0 B 13.1J Panel T00 / B 05 05 (4*ET) ET1316,ET1317,ET1318,ET1319
GTIC 0 B 13.1R Panel T00 / B 06 06 (4*ET) ET1320,ET1321,ET1322,ET1323
GTIC 0 B 13.1Z Panel T00 / B 07 07 (4*ET) ET1324,ET1325,ET1326,ET1327
GTIC 0 B 14.1A Panel T00 / B 08 08 (4*ET) ET1328,ET1329,ET1330,ET1331
GTIC 0 B 14.1J Panel T00 / B 09 09 (4*ET) ET1332,ET1333,ET1334,ET1335
GTIC 0 B 14.1R Panel T00 / B 10 10 (4*ET) ET1336,ET1337,ET1338,ET1339
GTIC 0 B 14.1Z Panel T00 / B 11 11 (4*ET) ET1340,ET1341,ET1342,ET1343

Table 35 Unbalanced panels in first deliveries (Cont.)

The equipping order in the cabling cabinet in upgrade deliveries is presented in the fol-
lowing table.

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
ETC 0 B 04.1A Panel 04 / B 56 56 (4*ET) ET560,ET561,ET562,ET563
ETC 0 B 04.1J Panel 04 / B 57 57 (4*ET) ET564,ET565,ET566,ET567
ETC 0 B 04.1R Panel 04 / B 58 58 (4*ET) ET568,ET569,ET570,ET571
ETC 0 B 04.1Z Panel 04 / B 59 59 (4*ET) ET572,ET573,ET574,ET575
ETC 1 B 01.1A Panel 04 / B 60 60 (4*ET) ET576,ET577,ET578,ET579
ETC 1 B 01.1J Panel 04 / B 61 61 (4*ET) ET580,ET581,ET582,ET583
ETC 1 B 01.1R Panel 04 / B 62 62 (4*ET) ET584,ET585,ET586,ET587
ETC 1 B 01.1Z Panel 04 / B 63 63 (4*ET) ET588,ET589,ET590,ET591
ETC 1 B 02.1A Panel 04 / B 48 48 (4*ET) ET592,ET593,ET594,ET595
ETC 1 B 02.1J Panel 04 / B 49 49 (4*ET) ET596,ET597,ET598,ET599

Table 36 Unbalanced panels in upgrade deliveries

76 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
ETC 1 B 02.1R Panel 04 / B 50 50 (4*ET) ET600,ET601,ET602,ET603
ETC 1 B 02.1Z Panel 04 / B 51 51 (4*ET) ET604,ET605,ET606,ET607
ETC 1 B 03.1A Panel 04 / B 52 52 (4*ET) ET608,ET609,ET610,ET611
ETC 1 B 03.1J Panel 04 / B 53 53 (4*ET) ET612,ET613,ET614,ET615
ETC 1 B 03.1R Panel 04 / B 54 54 (4*ET) ET616,ET617,ET618,ET619
ETC 1 B 03.1Z Panel 04 / B 55 55 (4*ET) ET620,ET621,ET622,ET623
ETC 1 B 04.1A Panel 04 / B 40 40 (4*ET) ET624,ET625,ET626,ET627
ETC 1 B 04.1J Panel 04 / B 41 41 (4*ET) ET628,ET629,ET630,ET631
ETC 1 B 04.1R Panel 04 / B 42 42 (4*ET) ET632,ET633,ET634,ET635
ETC 1 B 04.1Z Panel 04 / B 43 43 (4*ET) ET636,ET637,ET638,ET639
GTIC 0 / ETC B 01.1A (GTIC 0)
5 / B03.1A (ETC 5) Panel 04 / B 44 44 (4*ET) ET904,ET905,ET906,ET907
GTIC 0 / ETC B 01.1J (GTIC 0) /
5 B03.1J (ETC 5) Panel 04 / B 45 45 (4*ET) ET908,ET909,ET910,ET911
GTIC 0 / ETC B 01.1R (GTIC 0)
5 / B03.1R (ETC 5) Panel 04 / B 46 46 (4*ET) ET912,ET913,ET914,ET915
GTIC 0 / ETC B 01.1Z (GTIC 0)
5 / B03.1Z (ETC 5) Panel 04 / B 47 47 (4*ET) ET916,ET917,ET918,ET919
GTIC 0 / ETC B 02.1A (GTIC 0)
5 / B04.1A (ETC 5) Panel 04 / B 32 32 (4*ET) ET920,ET921,ET922,ET923
GTIC 0 / ETC B 02.1J (GTIC 0) /
5 B04.1J (ETC 5) Panel 04 / B 33 33 (4*ET) ET924,ET925,ET926,ET927
GTIC 0 / ETC B 02.1R (GTIC 0)
5 / B04.1R (ETC 5) Panel 04 / B 34 34 (4*ET) ET928,ET929,ET930,ET931
GTIC 0 / ETC B 02.1Z (GTIC 0)
5 / B04.1Z (ETC 5) Panel 04 / B 35 35 (4*ET) ET932,ET933,ET934,ET935
GTIC 0 / ETC B 03.1A (GTIC 0)
5 / B05.1A (ETC 5) Panel 04 / B 36 36 (4*ET) ET936,ET937,ET938,ET939
GTIC 0 / ETC B 03.1J (GTIC 0) /
5 B05.1J (ETC 5) Panel 04 / B 37 37 (4*ET) ET940,ET941,ET942,ET943
GTIC 0 / ETC B 03.1R (GTIC 0)
5 / B05.1R (ETC 5) Panel 04 / B 38 38 (4*ET) ET944,ET945,ET946,ET947
GTIC 0 / ETC B 03.1Z (GTIC 0)
5 / B05.1Z (ETC 5) Panel 04 / B 39 39 (4*ET) ET948,ET949,ET950,ET951
GTIC 0 / ETC B 04.1A (GTIC 0)
5 / B06.1A (ETC 5) Panel 04 / B 24 24 (4*ET) ET816,ET817,ET818,ET819
GTIC 0 / ETC B 04.1J (GTIC 0) /
5 B06.1J (ETC 5) Panel 04 / B 25 25 (4*ET) ET820,ET821,ET822,ET823

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d8058049ecb0 77
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
GTIC 0 / ETC B 04.1R (GTIC 0)
5 / B06.1R (ETC 5) Panel 04 / B 26 26 (4*ET) ET824,ET825,ET826,ET827
GTIC 0 / ETC B 04.1Z (GTIC 0)
5 / B06.1Z (ETC 5) Panel 04 / B 27 27 (4*ET) ETET828,ET829,ET830,ET831
GTIC 0 / ETC B 05.1A (GTIC 0) ET1072,ET1073,ET1074,ET107
5 / B07.1A (ETC 5) Panel 04 / B 28 28 (4*ET) 5
GTIC 0 / ETC B 05.1J (GTIC 0) / ET1076,ET1077,ET1078,ET107
5 B07.1J (ETC 5) Panel 04 / B 29 29 (4*ET) 9
GTIC 0 / ETC B 05.1R (GTIC 0) ET1080,ET1081,ET1082,ET108
5 / B07.1R (ETC 5) Panel 04 / B 30 30 (4*ET) 3
GTIC 0 / ETC B 05.1Z (GTIC 0) ET1084,ET1085,ET1086,ET108
5 / B07.1Z (ETC 5) Panel 04 / B 31 31 (4*ET) 7
GTIC 0 / ETC B 06.1A (GTIC 0) ET1328,ET1329,ET1330,ET133
5 / B08.1A (ETC 5) Panel 04 / B 16 16 (4*ET) 1
GTIC 0 / ETC B 06.1J (GTIC 0) / ET1332,ET1333,ET1334,ET133
5 B08.1J (ETC 5) Panel 04 / B 17 17 (4*ET) 5
GTIC 0 / ETC B 06.1R (GTIC 0) ET1336,ET1337,ET1338,ET133
5 / B08.1R (ETC 5) Panel 04 / B 18 18 (4*ET) 9
GTIC 0 / ETC B 06.1Z (GTIC 0) ET1340,ET1341,ET1342,ET134
5 / B08.1Z (ETC 5) Panel 04 / B 19 19 (4*ET) 3
ET1792,ET1793,ET1794,ET179
GTIC 0 B 07.1A Panel 04 / B 20 20 (4*ET) 5
ET1796,ET1797,ET1798,ET179
GTIC 0 B 07.1J Panel 04 / B 21 21 (4*ET) 9
ET1800,ET1801,ET1802,ET180
GTIC 0 B 07.1R Panel 04 / B 22 22 (4*ET) 3
ET1804,ET1805,ET1806,ET180
GTIC 0 B 07.1Z Panel 04 / B 23 23 (4*ET) 7
ET1808,ET1809,ET1810,ET181
GTIC 0 B 08.1A Panel 04 / B 08 08 (4*ET) 1
ET1812,ET1813,ET1814,ET181
GTIC 0 B 08.1J Panel 04 / B 09 09 (4*ET) 5
ET1816,ET1817,ET1818,ET181
GTIC 0 B 08.1R Panel 04 / B 10 10 (4*ET) 9
ET1820,ET1821,ET1822,ET182
GTIC 0 B 08.1Z Panel 04 / B 11 11 (4*ET) 3
ET1408,ET1409,ET1410,ET141
GTIC 1 B 01.1A Panel 04 / B 12 12 (4*ET) 1
ET1412,ET1413,ET1414,ET141
GTIC 1 B 01.1J Panel 04 / B 13 13 (4*ET) 5

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

78 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
ET1416,ET1417,ET1418,ET141
GTIC 1 B 01.1R Panel 04 / B 14 14 (4*ET) 9
ET1420,ET1421,ET1422,ET142
GTIC 1 B 01.1Z Panel 04 / B 15 15 (4*ET) 3
ET1424,ET1425,ET1426,ET142
GTIC 1 B 02.1A Panel 04 / B 00 00 (4*ET) 7
ET1428,ET1429,ET1430,ET143
GTIC 1 B 02.1J Panel 04 / B 01 01 (4*ET) 1
ET1432,ET1433,ET1434,ET143
GTIC 1 B 02.1R Panel 04 / B 02 02 (4*ET) 5
ET1436,ET1437,ET1438,ET143
GTIC 1 B 02.1Z Panel 04 / B 03 03 (4*ET) 9
ET1440,ET1441,ET1442,ET144
GTIC 1 B 03.1A Panel 04 / B 04 04 (4*ET) 3
ET1444,ET1445,ET1446,ET144
GTIC 1 B 03.1J Panel 04 / B 05 05 (4*ET) 7
ET1448,ET1449,ET1450,ET145
GTIC 1 B 03.1R Panel 04 / B 06 06 (4*ET) 1
ET1452,ET1453,ET1454,ET145
GTIC 1 B 03.1Z Panel 04 / B 07 07 (4*ET) 5

ET1456,ET1457,ET1458,ET145
GTIC 1 B 04.1A Panel 03 / B 10 10 (4*ET) 9
ET1460,ET1461,ET1462,ET146
GTIC 1 B 04.1J Panel 03 / B 11 11 (4*ET) 3
ET1464,ET1465,ET1466,ET146
GTIC 1 B 04.1R Panel 03 / B 08 08 (4*ET) 7
ET1468,ET1469,ET1470,ET147
GTIC 1 B 04.1Z Panel 03 / B 09 09 (4*ET) 1
ET1472,ET1473,ET1474,ET147
GTIC 1 B 05.1A Panel 03 / B 06 06 (4*ET) 5
ET1476,ET1477,ET1478,ET147
GTIC 1 B 05.1J Panel 03 / B 07 07 (4*ET) 9
ET1480,ET1481,ET1482,ET148
GTIC 1 B 05.1R Panel 03 / B 04 04 (4*ET) 3
ET1484,ET1485,ET1486,ET148
GTIC 1 B 05.1Z Panel 03 / B 05 05 (4*ET) 7
ET1488,ET1489,ET1490,ET149
GTIC 1 B 06.1A Panel 03 / B 02 02 (4*ET) 1
ET1492,ET1493,ET1494,ET149
GTIC 1 B 06.1J Panel 03 / B 03 03 (4*ET) 5

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d8058049ecb0 79
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
ET1496,ET1497,ET1498,ET149
GTIC 1 B 06.1R Panel 03 / B 00 00 (4*ET) 9
ET1500,ET1501,ET1502,ET150
GTIC 1 B 06.1Z Panel 03 / B 01 01 (4*ET) 3

ET1504,ET1505,ET1506,ET150
GTIC 1 B 07.1A Panel 02 / B 10 10 (4*ET) 7
ET1508,ET1509,ET1510,ET151
GTIC 1 B 07.1J Panel 02 / B 11 11 (4*ET) 1
ET1512,ET1513,ET1514,ET151
GTIC 1 B 07.1R Panel 02 / B 08 08 (4*ET) 5
ET1516,ET1517,ET1518,ET151
GTIC 1 B 07.1Z Panel 02 / B 09 09 (4*ET) 9
ET1520,ET1521,ET1522,ET152
GTIC 1 B 08.1A Panel 02 / B 06 06 (4*ET) 3
ET1524,ET1525,ET1526,ET152
GTIC 1 B 08.1J Panel 02 / B 07 07 (4*ET) 7
ET1528,ET1529,ET1530,ET153
GTIC 1 B 08.1R Panel 02 / B 04 04 (4*ET) 1
ET1532,ET1533,ET1534,ET153
GTIC 1 B 08.1Z Panel 02 / B 05 05 (4*ET) 5
ET1344,ET1345,ET1346,ET134
ETC 2 B 01.1A Panel 02 / B 02 02 (4*ET) 7
ET1348,ET1349,ET1350,ET135
ETC 2 B 01.1J Panel 02 / B 03 03 (4*ET) 1
ET1352,ET1353,ET1354,ET135
ETC 2 B 01.1R Panel 02 / B 00 00 (4*ET) 5
ET1356,ET1357,ET1358,ET135
ETC 2 B 01.1Z Panel 02 / B 01 01 (4*ET) 9

ET1360,ET1361,ET1362,ET136
ETC 2 B 02.1A Panel 01 / B 10 10 (4*ET) 3
ET1364,ET1365,ET1366,ET136
ETC 2 B 02.1J Panel 01 / B 11 11 (4*ET) 7
ET1368,ET1369,ET1370,ET137
ETC 2 B 02.1R Panel 01 / B 08 08 (4*ET) 1
ET1372,ET1373,ET1374,ET137
ETC 2 B 02.1Z Panel 01 / B 09 09 (4*ET) 5
ET1376,ET1377,ET1378,ET137
ETC 2 B 03.1A Panel 01 / B 06 06 (4*ET) 9

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

80 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
ET1380,ET1381,ET1382,ET138
ETC 2 B 03.1J Panel 01 / B 07 07 (4*ET) 3
ET1384,ET1385,ET1386,ET138
ETC 2 B 03.1R Panel 01 / B 04 04 (4*ET) 7
ET1388,ET1389,ET1390,ET139
ETC 2 B 03.1Z Panel 01 / B 05 05 (4*ET) 1
ET1392,ET1393,ET1394,ET139
ETC 2 B 04.1A Panel 01 / B 02 02 (4*ET) 5
ET1396,ET1397,ET1398,ET139
ETC 2 B 04.1J Panel 01 / B 03 03 (4*ET) 9
ET1400,ET1401,ET1402,ET140
ETC 2 B 04.1R Panel 01 / B 00 00 (4*ET) 3
ET1404,ET1405,ET1406,ET140
ETC 2 B 04.1Z Panel 01 / B 01 01 (4*ET) 7

ET1600,ET1601,ET1602,ET160
ETC 2 B 05.1A Panel 00 / B 56 56 (4*ET) 3
ET1604,ET1605,ET1606,ET160
ETC 2 B 05.1J Panel 00 / B 57 57 (4*ET) 7
ET1608,ET1609,ET1610,ET161
ETC 2 B 05.1R Panel 00 / B 58 58 (4*ET) 1
ET1612,ET1613,ET1614,ET161
ETC 2 B 05.1Z Panel 00 / B 59 59 (4*ET) 5
ET1616,ET1617,ET1618,ET161
ETC 2 B 06.1A Panel 00 / B 60 60 (4*ET) 9
ET1620,ET1621,ET1622,ET162
ETC 2 B 06.1J Panel 00 / B 61 61 (4*ET) 3
ET1624,ET1625,ET1626,ET162
ETC 2 B 06.1R Panel 00 / B 62 62 (4*ET) 7
ET1628,ET1629,ET1630,ET163
ETC 2 B 06.1Z Panel 00 / B 63 63 (4*ET) 1
ET1632,ET1633,ET1634,ET163
ETC 2 B 07.1A Panel 00 / B 48 48 (4*ET) 5
ET1636,ET1637,ET1638,ET163
ETC 2 B 07.1J Panel 00 / B 49 49 (4*ET) 9
ET1640,ET1641,ET1642,ET164
ETC 2 B 07.1R Panel 00 / B 50 50 (4*ET) 3
ET1644,ET1645,ET1646,ET164
ETC 2 B 07.1Z Panel 00 / B 51 51 (4*ET) 7
ET1648,ET1649,ET1650,ET165
ETC 2 B 08.1A Panel 00 / B 52 52 (4*ET) 1

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d8058049ecb0 81
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
ET1652,ET1653,ET1654,ET165
ETC 2 B 08.1J Panel 00 / B 53 53 (4*ET) 5
ET1656,ET1657,ET1658,ET165
ETC 2 B 08.1R Panel 00 / B 54 54 (4*ET) 9
ET1660,ET1661,ET1662,ET166
ETC 2 B 08.1Z Panel 00 / B 55 55 (4*ET) 3
ET1664,ET1665,ET1666,ET166
ETC 3 B 01.1A Panel 00 / B 40 40 (4*ET) 7
ET1668,ET1669,ET1670,ET167
ETC 3 B 01.1J Panel 00 / B 41 41 (4*ET) 1
ET1672,ET1673,ET1674,ET167
ETC 3 B 01.1R Panel 00 / B 42 42 (4*ET) 5
ET1676,ET1677,ET1678,ET167
ETC 3 B 01.1Z Panel 00 / B 43 43 (4*ET) 9
ET1680,ET1681,ET1682,ET168
ETC 3 B 02.1A Panel 00 / B 44 44 (4*ET) 3
ET1684,ET1685,ET1686,ET168
ETC 3 B 02.1J Panel 00 / B 45 45 (4*ET) 7
ET1688,ET1689,ET1690,ET169
ETC 3 B 02.1R Panel 00 / B 46 46 (4*ET) 1
ET1692,ET1693,ET1694,ET169
ETC 3 B 02.1Z Panel 00 / B 47 47 (4*ET) 5
ET1696,ET1697,ET1698,ET169
ETC 3 B 03.1A Panel 00 / B 32 32 (4*ET) 9
ET1700,ET1701,ET1702,ET170
ETC 3 B 03.1J Panel 00 / B 33 33 (4*ET) 3
ET1704,ET1705,ET1706,ET170
ETC 3 B 03.1R Panel 00 / B 34 34 (4*ET) 7
ET1708,ET1709,ET1710,ET171
ETC 3 B 03.1Z Panel 00 / B 35 35 (4*ET) 1
ET1712,ET1713,ET1714,ET171
ETC 3 B 04.1A Panel 00 / B 36 36 (4*ET) 5
ET1716,ET1717,ET1718,ET171
ETC 3 B 04.1J Panel 00 / B 37 37 (4*ET) 9
ET1720,ET1721,ET1722,ET172
ETC 3 B 04.1R Panel 00 / B 38 38 (4*ET) 3
ET1724,ET1725,ET1726,ET172
ETC 3 B 04.1Z Panel 00 / B 39 39 (4*ET) 7
ET1728,ET1729,ET1730,ET173
ETC 3 B 05.1A Panel 00 / B 24 24 (4*ET) 1

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

82 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
ET1732,ET1733,ET1734,ET173
ETC 3 B 05.1J Panel 00 / B 25 25 (4*ET) 5
ET1736,ET1737,ET1738,ET173
ETC 3 B 05.1R Panel 00 / B 26 26 (4*ET) 9
ET1740,ET1741,ET1742,ET174
ETC 3 B 05.1Z Panel 00 / B 27 27 (4*ET) 3
ET1744,ET1745,ET1746,ET174
ETC 3 B 06.1A Panel 00 / B 28 28 (4*ET) 7
ET1748,ET1749,ET1750,ET175
ETC 3 B 06.1J Panel 00 / B 29 29 (4*ET) 1
ET1752,ET1753,ET1754,ET175
ETC 3 B 06.1R Panel 00 / B 30 30 (4*ET) 5
ET1756,ET1757,ET1758,ET175
ETC 3 B 06.1Z Panel 00 / B 31 31 (4*ET) 9
ET1760,ET1761,ET1762,ET176
ETC 3 B 07.1A Panel 00 / B 16 16 (4*ET) 3
ET1764,ET1765,ET1766,ET176
ETC 3 B 07.1J Panel 00 / B 17 17 (4*ET) 7
ET1768,ET1769,ET1770,ET177
ETC 3 B 07.1R Panel 00 / B 18 18 (4*ET) 1
ET1772,ET1773,ET1774,ET177
ETC 3 B 07.1Z Panel 00 / B 19 19 (4*ET) 5
ET1776,ET1777,ET1778,ET177
ETC 3 B 08.1A Panel 00 / B 20 20 (4*ET) 9
ET1780,ET1781,ET1782,ET178
ETC 3 B 08.1J Panel 00 / B 21 21 (4*ET) 3
ET1784,ET1785,ET1786,ET178
ETC 3 B 08.1R Panel 00 / B 22 22 (4*ET) 7
ET1788,ET1789,ET1790,ET179
ETC 3 B 08.1Z Panel 00 / B 23 23 (4*ET) 1
ET1920,ET1921,ET1922,ET192
ETC 4 B 01.1A Panel 00 / B 08 08 (4*ET) 3
ET1924,ET1925,ET1926,ET192
ETC 4 B 01.1J Panel 00 / B 09 09 (4*ET) 7
ET1928,ET1929,ET1930,ET193
ETC 4 B 01.1R Panel 00 / B 10 10 (4*ET) 1
ET1932,ET1933,ET1934,ET193
ETC 4 B 01.1Z Panel 00 / B 11 11 (4*ET) 5
ET1936,ET1937,ET1938,ET193
ETC 4 B 02.1A Panel 00 / B 12 12 (4*ET) 9

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

DN70617303 Id:0900d8058049ecb0 83
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

ETC/GTIC From GT4C-A To panel / connector Multicoaxial Corresponding external ET


cartridge connector position front ports in numbers
position CPETC-E panel
through this
cable
ET1940,ET1941,ET1942,ET194
ETC 4 B 02.1J Panel 00 / B 13 13 (4*ET) 3
ET1944,ET1945,ET1946,ET194
ETC 4 B 02.1R Panel 00 / B 14 14 (4*ET) 7
ET1948,ET1949,ET1950,ET195
ETC 4 B 02.1Z Panel 00 / B 15 15 (4*ET) 1
ET1952,ET1953,ET1954,ET195
ETC 4 B 03.1A Panel 00 / B 00 00 (4*ET) 5
ET1956,ET1957,ET1958,ET195
ETC 4 B 03.1J Panel 00 / B 01 01 (4*ET) 9
ET1960,ET1961,ET1962,ET196
ETC 4 B 03.1R Panel 00 / B 02 02 (4*ET) 3
ET1964,ET1965,ET1966,ET196
ETC 4 B 03.1Z Panel 00 / B 03 03 (4*ET) 7
ET1968,ET1969,ET1970,ET197
ETC 4 B 04.1A Panel 00 / B 04 04 (4*ET) 1
ET1972,ET1973,ET1974,ET197
ETC 4 B 04.1J Panel 00 / B 05 05 (4*ET) 5
ET1976,ET1977,ET1978,ET197
ETC 4 B 04.1R Panel 00 / B 06 06 (4*ET) 9
ET1980,ET1981,ET1982,ET198
ETC 4 B 04.1Z Panel 00 / B 07 07 (4*ET) 3

Table 36 Unbalanced panels in upgrade deliveries (Cont.)

5.3 TCSM3i
Two installation options of the third-generation Transcoder Submultiplexer are available:
the TCSM3i for stand-alone installation option and the TCSM3i for combined
BSC/TCSM installation option. The TCSM3i for stand-alone installation option always
has a cabling cabinet, but the TCSM3i for combined BSC/TCSM installation option does
not have a cabling cabinet.

5.3.1 TCSM3i for stand-alone installation option


In the TCSM3i for stand-alone installation option, the cabling cabinet is always mounted
to the TCSA cabinet. Balanced cabling panel is default, whereas the unbalanced is
optional and must be ordered separately.

E1 (PCM) unbalanced trunk cable panel (CPETC-F)


The unbalanced connector panels for the TCSM3i are shown in the following table.

84 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

Panel Connector panel


number
0 CPETC-F
1 CPBP
2 CPBP
3 CPBP
4 CPETC-F

Table 37 Unbalanced connector panels for the TCSM3i

Recommended cable type for E1 coaxial trunk cables is CPRD. See the following table
and figure.

Cable type Filotex ET 267 380


Cable connector D37 connector body, type FCI DC8W8PA00; or ITT Cannon
DCM-8W8P-A197
Coaxial inserts Rosenberger 55S101-302E2; IMS 307.23.2415.421

Table 38 Recommended cable type for E1 coaxial trunk cables (CPRD)

DN99257685

A1 A8
Figure 18 CPRD cable assembly (panel end connector mounted)

Equipping order
The cabling cabinet is used with the TCSM3i for stand-alone installation option.
The D-connector in the unbalanced panels is shown in the following figure and the
equipping order in the cabling cabinet is presented in the following table.

DN70617303 Id:0900d8058049ecb0 85
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

86 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

Figure 19 D-connector

ETC car- From GT4C-A To panel / Multicoaxial Coaxial insert pairs of the Multicoaxial front
tridge connector connector front ports in ports used by
position position CPETC-F
panel
through this
cable
ETC 0 B 01.1A Panel 0 / B 00 00 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 01
ETC 0 B 01.1J Panel 0 / B 01 01 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 02
ETC 0 B 01.1R Panel 0 / B 02 02 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 03
ETC 0 B 01.1Z Panel 0 / B 03 03 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 04
ETC 1 B 01.1A Panel 0 / B 04 04 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 05
ETC 1 B 01.1J Panel 0 / B 05 05 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 06
ETC 1 B 01.1R Panel 0 / B 06 06 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 07
ETC 1 B 01.1Z Panel 0 / B 07 07 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 08
ETC 2 B 01.1A Panel 0 / B 08 08 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 09
ETC 2 B 01.1J Panel 0 / B 09 09 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 10
ETC 2 B 01.1R Panel 0 / B 10 10 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 11
ETC 2 B 01.1Z Panel 0 / B 11 11 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 12
ETC 1 B 02.1A Panel 0 / B12 12 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 13
ETC 1 B 02.1J Panel 0 / B13 13 (4*ET) A-interf. PCM1-4/ TR3 in TC2C0 slot 14
ETC 1 B 02.1R Panel 0 / B14 14 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 15
ETC 1 B 02.1Z Panel 0 / B15 15 (4*ET) A-interf. PCM1-4 / TR3 in TC2C0 slot 16
ETC 0 B 02.1A Panel 0 / B16 16 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 01
ETC 0 B 02.1J Panel 0 / B17 17 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 02
ETC 0 B 02.1R Panel 0 / B18 18 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 03
ETC 0 B 02.1Z Panel 0 / B19 19 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 04
ETC 1 B 03.1A Panel 0 / B20 20 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 05
ETC 1 B 03.1J Panel 0 / B21 21 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 06
ETC 1 B 03.1R Panel 0 / B22 22 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 07
ETC 1 B 03.1Z Panel 0 / B23 23 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 08
ETC 2 B 02.1A Panel 0 / B24 24 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 09
ETC 2 B 02.1J Panel 0 / B25 25 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 10
ETC 2 B 02.1R Panel 0 / B26 26 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 11
ETC 2 B 02.1Z Panel 0 / B27 27 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 12
ETC 1 B 04.1A Panel 0 / B28 28 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 13
ETC 1 B 04.1J Panel 0 / B29 29 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 14
ETC 1 B 04.1R Panel 0 / B30 30 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 15

Table 39 Unbalanced panels in cabling cabinet - A-interface

DN70617303 Id:0900d8058049ecb0 87
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

ETC car- From GT4C-A To panel / Multicoaxial Coaxial insert pairs of the Multicoaxial front
tridge connector connector front ports in ports used by
position position CPETC-F
panel
through this
cable
ETC 1 B 04.1Z Panel 0 / B31 31 (4*ET) A-interf. PCM1-4 / TR3 in TC2C1 slot 16
ETC 0 B 03.1A Panel 0 / B32 32 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 01
ETC 0 B 03.1J Panel 0 / B33 33 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 02
ETC 0 B 03.1R Panel 0 / B34 34 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 03
ETC 0 B 03.1Z Panel 0 / B35 35 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 04
ETC 1 B 05.1A Panel 0 / B36 36 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 05
ETC 1 B 05.1J Panel 0 / B37 37 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 06
ETC 1 B 05.1R Panel 0 / B38 38 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 07
ETC 1 B 05.1Z Panel 0 / B39 39 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 08
ETC 2 B 03.1A Panel 0 / B40 40 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 09
ETC 2 B 03.1J Panel 0 / B41 41 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 10
ETC 2 B 03.1R Panel 0 / B42 42 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 11
ETC 2 B 03.1Z Panel 0 / B43 43 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 12
ETC 1 B 06.1A Panel 0 / B44 44 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 13
ETC 1 B 06.1J Panel 0 / B45 45 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 14
ETC 1 B 06.1R Panel 0 / B46 46 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 15
ETC 1 B 06.1Z Panel 0 / B47 47 (4*ET) A-interf. PCM1-4 / TR3 in TC2C2 slot 16
ETC 0 B 04.1A Panel 0 / B48 48 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 01
ETC 0 B 04.1J Panel 0 / B49 49 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 02
ETC 0 B 04.1R Panel 0 / B50 50 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 03
ETC 0 B 04.1Z Panel 0 / B51 51 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 04
ETC 1 B 07.1A Panel 0 / B52 52 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 05
ETC 1 B 07.1J Panel 0 / B53 53 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 06
ETC 1 B 07.1R Panel 0 / B54 54 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 07
ETC 1 B 07.1Z Panel 0 / B55 55 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 08
ETC 2 B 04.1A Panel 0 / B56 56 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 09
ETC 2 B 04.1J Panel 0 / B57 57 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 10
ETC 2 B 04.1R Panel 0 / B58 58 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 11
ETC 2 B 04.1Z Panel 0 / B59 59 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 12
ETC 1 B 08.1A Panel 0 / B60 60 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 13
ETC 1 B 08.1J Panel 0 / B61 61 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 14
ETC 1 B 08.1R Panel 0 / B62 62 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 15
ETC 1 B 08.1Z Panel 0 / B63 63 (4*ET) A-interf. PCM1-4 / TR3 in TC2C3 slot 16

Table 39 Unbalanced panels in cabling cabinet - A-interface (Cont.)

88 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC E1 (PCM) unbalanced trunk cable panels (CPETC-E
and TCSM3i and CPETC-F)

ETC car- From GT4C-A To panel / Multicoaxial Coaxial insert pairs of the Multicoaxial front
tridge connector connector front ports in ports used by
position position CPETC-F
panel
through this
cable

ETC 0 B 05.1A Panel 4 / B00 00 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 01
ETC 0 B 05.1J Panel 4 / B01 01 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 02
ETC 0 B 05.1R Panel 4 / B02 02 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 03
ETC 0 B 05.1Z Panel 4 / B03 03 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 04
ETC 2 B 05.1A Panel 4 / B04 04 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 05
ETC 2 B 05.1J Panel 4 / B05 05 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 06
ETC 2 B 05.1R Panel 4 / B06 06 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 07
ETC 2 B 05.1Z Panel 4 / B07 07 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 08
ETC 0 B 06.1A Panel 4 / B08 08 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 09
ETC 0 B 06.1J Panel 4 / B09 09 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 10
ETC 0 B 06.1R Panel 4 / B10 10 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 11
ETC 0 B 06.1Z Panel 4 / B11 11 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 12
ETC 2 B 06.1A Panel 4 / B12 12 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 13
ETC 2 B 06.1J Panel 4 / B13 13 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 14
ETC 2 B 06.1R Panel 4 / B14 14 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 15
ETC 2 B 06.1Z Panel 4 / B15 15 (4*ET) A-interf. PCM1-4 / TR3 in TC2C4 slot 16
ETC 0 B 07.1A Panel 4 / B16 16 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 01
ETC 0 B 07.1J Panel 4 / B17 17 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 02
ETC 0 B 07.1R Panel 4 / B18 18 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 03
ETC 0 B 07.1Z Panel 4 / B19 19 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 04
ETC 2 B 07.1A Panel 4 / B20 20 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 05
ETC 2 B 07.1J Panel 4 / B21 21 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 06
ETC 2 B 07.1R Panel 4 / B22 22 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 07
ETC 2 B 07.1Z Panel 4 / B23 23 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 08
ETC 0 B 08.1A Panel 4 / B24 24 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 09
ETC 0 B 08.1J Panel 4 / B25 25 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 10
ETC 0 B 08.1R Panel 4 / B26 26 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 11
ETC 0 B 08.1Z Panel 4 / B27 27 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 12
ETC 2 B 08.1A Panel 4 / B28 28 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 13
ETC 2 B 08.1J Panel 4 / B29 29 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 14
ETC 2 B 08.1R Panel 4 / B30 30 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 15
ETC 2 B 08.1Z Panel 4 / B31 31 (4*ET) A-interf. PCM1-4 / TR3 in TC2C5 slot 16

Table 39 Unbalanced panels in cabling cabinet - A-interface (Cont.)

DN70617303 Id:0900d8058049ecb0 89
Issue 1-0
E1 (PCM) unbalanced trunk cable panels (CPETC-E Connector Panels and External Cables in Flexi BSC
and CPETC-F) and TCSM3i

From car- TR3 unit slot From ET16 slot and con- ET panel / front ports
tridge nector position through this cable
TC2C 0 01, 02, 03, 04 B 17.1A Panel 4 / 32 (4*ET)
TC2C 0 05, 06, 07, 08 B 17.1J Panel 4 / 33 (4*ET)
TC2C 0 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 34 (4*ET)
TC2C 0 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 35 (4*ET)
TC2C 1 01, 02, 03, 04 B 17.1A Panel 4 / 36 (4*ET)
TC2C 1 05, 06, 07, 08 B 17.1J Panel 4 / 37 (4*ET)
TC2C 1 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 38 (4*ET)
TC2C 1 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 39 (4*ET)
TC2C 2 01, 02, 03, 04 B 17.1A Panel 4 / 40 (4*ET)
TC2C 2 05, 06, 07, 08 B 17.1J Panel 4 / 41 (4*ET)
TC2C 2 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 42 (4*ET)
TC2C 2 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 43 (4*ET)
TC2C 3 01, 02, 03, 04 B 17.1A Panel 4 / 44 (4*ET)
TC2C 3 05, 06, 07, 08 B 17.1J Panel 4 / 45 (4*ET)
TC2C 3 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 46 (4*ET)
TC2C 3 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 47 (4*ET)
TC2C 4 01, 02, 03, 04 B 17.1A Panel 4 / 48 (4*ET)
TC2C 4 05, 06, 07, 08 B 17.1J Panel 4 / 49 (4*ET)
TC2C 4 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 50 (4*ET)
TC2C 4 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 51 (4*ET)
TC2C 5 01, 02, 03, 04 B 17.1A Panel 4 / 52 (4*ET)
TC2C 5 05, 06, 07, 08 B 17.1J Panel 4 / 53 (4*ET)
TC2C 5 09, 10, 11, 12 B 17.1R or B18.1A *) Panel 4 / 54 (4*ET)
TC2C 5 13, 14, 15, 16 B 17.1Z or B18.1J *) Panel 4 / 55 (4*ET)
Notes
*) Connector positions B 17.1R and B 17.1Z are default positions when the TC2C cartridge is used
for transcoder connections of one BSC.
Connector positions B 18.1A and B 18.1J are in use when the TC2C cartridge is used for transcoder
connections of two BSCs (one half of the TC2C cartridge for one BSC and the other half for the other
BSC).

Table 40 Unbalanced panels in cabling cabinet - Ater-interface

5.3.2 TCSM3i for combined BSC/TCSM installation option


The cabling cabinet is not used with the TCSA cabinet in the TCSM3i for combined
BSC/TCSM installation option. Instead, the optical cabling from the front connectors of
the ETS2 plug-in units is routed out of the cabinet through the CPGO at the cabinet top.

90 Id:0900d8058049ecb0 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)

6 Roof panel with LAN, LPT/VDU, and synchro-


nisation and alarm interfaces (CPRJ45-A)
The CPRJ45-A panel is located in the middle hole at the BSCC cabinet top and it can
be installed without the RACP adapter. The CPRJ45-A provides interfaces for 100
Mbit/s and 1 Gbit/s LAN uplinks, LPTs and VDUs, incoming external synchronisation
signals, and inputs and outputs for external alarms.

LAN INTERFACES
10/100/1000Base-T/Tx uplinks 1000Base-Sx uplinks
00 01 02 03 04 05 06 07

CLASS 1 LASER PRODUCT


Tx Rx Tx Rx Tx Rx Tx Rx

IEC/EN 60825 - 1
08 09 10 11 12 13 14 15

Tx Rx Tx Rx Tx Rx Tx Rx

SYMM 0 SYMM 1
20 ASYMM 0 21 22 23
LPT 0 VDU 0 CLS 0, 1 CLS 0, 1 CLS 0,1
16 17 18 19
(V.24) (V.24)

28 ASYMM 1
VDU 1 VDU 2 VDU 2 LPT 2 CLS 0,1
24 24 26 27
(V.24) (V.24) (V.11) (V.11)
CURRENT-
CONTROLLED
EXT SYNC IN EXT AL INPUT EXT AL OUTPUT AL INPUTS
LPT/VDU INTERFACES INTERFACES EXT AL INTERFACES
B A

DN0626528

Figure 20 Panel CPRJ45-A with LAN, alarm, LPT/VDU, and synchronisation inter-
faces - seen from the front of the cabinet
The various interfaces are presented in the following sections:
LAN interfaces
External alarm cabling
LPT/VDU interfaces
External synchronisation cabling

6.1 LAN interfaces


Both 1000Base-Sx LAN interfaces (ports 04 to 07, 12 to 15) for 1 Gbit/s uplinks and
10/100/1000Base-T/Tx LAN interfaces (ports 00 to 03, 08 to 11) for 10/100 Mbit/s and
1 Gbit/s copper uplinks in CPRJ45-A panel are used.
For more information, see
1 Gbit/s optical uplink LAN cables

DN70617303 Id:0900d805804ab823 91
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i

10/100 Mbit/s / 1 Gbit/s copper uplink LAN cables

6.1.1 1 Gbit/s optical uplink LAN cables


The Duplex LC connectors (04-07 and 12-15) in the connector panel CPRJ45-A are
reserved for 1 Gbit/s optical uplink LAN cables. The optical uplink LAN interfaces in the
CPRJ45-A panel are cabled to the front connectors of Ethernet Switch plug-in units
using CLCS cables.
The following figure presents optical LC connectors.

Dust 30 5
caps to LC DN70631285
connectors
Figure 21 Optical LC connectors, straight type
The following table presents the main characteristics of the optical cables and connec-
tors.

Fibre cable mate- 62.5/125 m multimode fibre


rial:
Straight connec- Duplex LC, according to GR-326 , IEC 60874
tors:

The cables and the connectors should meet the requirements of the UL 1459 standard
or the National Electrical Code ANSI/NFPA No.70 and the requirements of the FCC Part
68.

6.1.2 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cables


The RJ45 connectors (00 to 03 and 08 to 11) in the connector panel CPRJ45-A are
reserved for 10/100 Mbit/s / 1 Gbit/s copper uplink LAN cabling. The uplink LAN inter-
faces in the CPRJ45-A panel are cabled to the front connectors of Ethernet Switch plug-
in units.
The cable types available for external 10/100 Mbits/1Gbits uplink cabling are the follow-
ing:
CNIX (cross-connected cable); connector type RJ45 modular connector (8-pole)
CNI (straight-connected cable); connector type RJ45 modular connector (8-pole)
The pin configuration in 10/100 Mbit/s use of the CNIX cable connector is presented in
the following table.

Connector 1 Connector Signal at Colour Remarks


2 CPRJ45
1 3 TX+ Orange/White Transmit (Tx)
2 6 TX- Orange Transmit (Tx)

Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-
nected cable)

92 Id:0900d805804ab823 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)

Connector 1 Connector Signal at Colour Remarks


2 CPRJ45
3 1 RX+ White/Green Receive (Rx)
6 2 RX- Green Receive (Rx)
4 7 Blue
5 8 White/Blue
7 4 White/Brown
8 5 Brown

Table 41 CNIX cable connector, pin configuration in 10/100 Mbit/s use (cross-con-
nected cable) (Cont.)

The pin configuration in 1 Gbit/s use of the CNIX cable connector is presented in the fol-
lowing table.

Connector Connector Signal at Colour Remarks


1 2 CPRJ45
1 3 BI_DA+ Orange/White Transmit (Tx)
2 6 BI_DA- Orange Transmit (Tx)
3 1 BI_DB+ White/Green Receive (Rx)
6 2 BI_DB- Green Receive (Rx)
4 7 BI_DC+ Blue
5 8 BI_DC- White/Blue
7 4 BI_DD+ White/Brown
8 5 BI_DD- Brown

Table 42 CNIX cable connector, pin configuration in 1 Gbit/s use (cross-connected


cable)

The pin configuration in 10/100 Mbit/s use of the CNI cable connector is presented in
the following table.

Connector 1, 2 Signal at Colour Remarks


CPRJ45-A
1 RX+ Orange/White Receive positive
(Rx)
2 RX- Orange Receive negative
(Rx)
3 TX+ White/Green Transmit positive
(Tx)
4 Blue
5 White/Blue

Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-
nected cable)

DN70617303 Id:0900d805804ab823 93
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i

Connector 1, 2 Signal at Colour Remarks


CPRJ45-A
6 TX- Green Transmit negative
(Tx)
7 White/Brown
8 Brown

Table 43 CNI cable connector, pin configuration in 10/100 Mbit/s use (straight-con-
nected cable) (Cont.)

The pin configuration in 1 Gbit/s use of the CNI cable connector is presented in the fol-
lowing table.

Connector 1, 2 Signal at Colour Remarks


CPRJ45-A
1 BI_DB+ Orange/White Bi-rectional positive
2 BI_DB- Orange Bi-rectional
negative
3 BI_DA+ White/Green Bi-rectional positive
4 BI_DD+ Blue Bi-rectional positive
5 BI_DD- White/Blue Bi-rectional
negative
6 BI_DA- Green Bi-rectional
negative
7 BI_DC+ White/Brown Bi-rectional positive
8 BI_DC- Brown Bi-rectional
negative

Table 44 CNI cable connector, pin configuration in 1 Gbit/s use (straight-connected


cable)

The main characteristics of 10/100 Mbit/s /1 Gbit/s copper LAN cables are presented in
the following table.

Cable type: 4 pairs, twisted, shielded (S-FTP), Cat. 5 E or better,


AWG24/26
Cable connector: Shielded RJ45 modular connector (8-pole), Cat. 5 E or better

Table 45 Recommended cable types for LAN cables (CNI and CNIX)

The LAN interfaces complying with the IEEE 802.3 standard for Ethernet serial inter-
faces are of 10 Base-T and 100 Base-TX.
For more information, see Requirement specifications for external cables of M98
mechanics BSC3i and TCSM3i equipment.

94 Id:0900d805804ab823 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)

6.2 External alarm cabling


The CPRJ45-A panel accommodates two D25 connectors, one (21) for external alarm
inputs and one (22) for external alarm outputs. There is also one D9 connector (23) for
voltage and current-controlled alarm inputs. The CPRJ45-A is located in the middle hole
at the equipment cabinet top.
The external alarm cabling connectors are shown in the following table.

Connector Cable, Connector Cable type


21 CYR, 25-pin D-connector, male. Milliflex3 SH AWG26/15 pairs
Other end has no connector
22 CNDE, two 25-pin D-connec- Milliflex3 SH AWG26/15 pairs
tors, male. Other end only par-
tially connected
23 CYV 9-pin D-connector, male. Milliflex3 SH AWG26/8 pairs
Other end has no connector

Table 46 External alarm cabling connectors in the CPRJ45-A panel

External alarm output signals - CNDE cable


External Alarm output signals at the CPRJ45-A panel and configurations of CNDE cable
with D25 connectors are presented in the following table.

Pin Alarms CNDE CNDE CNDC


CPRJ45-A Connector 22 Connector 1 Colour Connector 2
panel, connec- (EXT AL
tor 22 OUTPUT
1 AEO0 1 Blue/White 1 (EXAU-A)
2 AEO1 2 White/Blue 3 (EXAU-A)
3 AEO2 3 Orange/Whit 5 (EXAU-A)
e
4 AEO3 4 White/Orang 7 (EXAU-A)
e
5 AEO4 5 Green/White 9 (EXAU-A)
6 AEO5 6 White/Green 11 (EXAU-A)
7 AEO6 7 Brown/White 13 (EXAU-A)
8 AEO7 8 White/Brown 15 (EXAU-A)
9 AEO8 9 Grey/White 17 (EXAU-A)
10 AEO9 10 White/Grey 19 (EXAU-A)
11 AE10 11 Blue/Yellow 21 (EXAU-A)
12 AE11 12 Yellow/Blue 23 (EXAU-A)
13 AE12 13 Orange/Yel- nc
low

Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable
with D25 connectors

DN70617303 Id:0900d805804ab823 95
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i

Pin Alarms CNDE CNDE CNDC


CPRJ45-A Connector 22 Connector 1 Colour Connector 2
panel, connec- (EXT AL
tor 22 OUTPUT
14 AE13 14 Yel- nc
low/Orange
15 AE14 15 Green/Yellow nc
16 AE15 16 Yellow/Green nc
17 - 17 Brow/Yellow nc
18 - 18 Yellow/Brown nc
19 - 19 Grey/Yellow nc
20 - 20 Yellow/Grey nc
21 - 21 Blue/Violet nc
22 - 22 Violet/Blue nc
23 - 23 Orange/Vio- nc
let
24 - 24 Vio- nc
let/Orange
25 GND 25 Green/Violet 2, 4, 6, 8, 10,
12, 14, 16, 18,
20, 22, 24, 25
- - nc Violet/Green nc
- - nc Brow/Violet nc
- - nc Violet/Brown nc
- - nc Grey/Violet nc
- - nc Violet/Grey nc
- - 25 Connector Screen wire Connector
hood hood
Hood GND Connector Cable shield Connector
hood hood
Notes
AEO = External alarm output signal
GND = Ground signal

Table 47 Alarm signals at the CPRJ45-A panel and pin configuration of CNDE cable
with D25 connectors (Cont.)

Alarms AEO0-AEO11 are connected directly to the EXAU-A with cable CNDE. All
alarms AEO0-AEO15 can be connected to the cross connection (DDF) with cable CNDE
(the other cable end, connector 2, cut off).
Four lengths of CNDE cable are available (ID codes presented):
5 m: C106809
10 m: C106819
20 m: C108435

96 Id:0900d805804ab823 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)

50 m: C107185

Voltage controlled external alarm inputs - alarm cable CYR

Pin; Alarms; Alarm cable Alarm cable


CYR; CYR;
CPRJ45-A Connector 21 Pin in Connector Colour
panel, connec- (Voltage and 1
tor 21 current-controlled
EXT AL INPUT)
1 AEI0 1 Blue/White
2 AEI1 2 White/Blue
3 AEI2 3 Orange/White
4 AEI3 4 White/Orange
5 AEI4 5 Green/White
6 AEI5 6 White/Green
7 AEI6 7 Brown/White
8 AEI7 8 White/Brown
9 AEI8 9 Grey/White
10 AEI9 10 White/Grey
11 AEI10 11 Blue/Yellow
12 AEI11 12 Yellow/Blue
13 AEI12 13 Orange/Yellow
14 AEI13 14 Yellow/Orange
15 AEI14 15 Green/Yellow
16 AEI15 16 Yellow/Green
17 AEI16 17 Brown/Yellow
18 AEI17 18 Yellow/Brown
19 AEI18 19 Grey/Yellow
20 AEI19 20 Yellow/Grey
21 AEI20 21 Blue/Purple
22 AEI21 22 Purple/Blue
23 AEI22 23 Orange/Purple
24 AEI23 24 Purple/Orange
25 GND 25 Green/Violet
- - nc Violet/Green
- - nc Brown/Violet
- - nc Violet/Brown
- - nc Grey/Violet

Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs,


AEIx)

DN70617303 Id:0900d805804ab823 97
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i

Pin; Alarms; Alarm cable Alarm cable


CYR; CYR;
CPRJ45-A Connector 21 Pin in Connector Colour
panel, connec- (Voltage and 1
tor 21 current-controlled
EXT AL INPUT)
- - nc Violet/Grey
- - 25 Connector Screen wire
hood
Hood GND Connector hood Cable shield
Note
AEI = Voltage controlled external alarm input signal

Table 48 Signals on panel connector 21 (Voltage and current-controlled AL inputs,


AEIx) (Cont.)

Voltage controlled external alarm input signals are connected from MDF to CPRJ45-A
panel using CYR cable. Three lengths are available (CS codes presented):
35 m: CS73131.35
50 m: CS73131.50
70 m: CS73131.70
24 external voltage controlled alarm inputs can be connected to Flexi BSC using the
CYR cable.

Current-controlled external alarm inputs

Pin; Alarms; Alarm cable Alarm cable


CYV; CYV;
CPRJ45-A Connector 23 Pin in Connector Colour
panel, connec- (Voltage and 1
tor 23 current-controlled
EXT AL INPUT)
1 ALS0 1 Blue/White
2 ALS1 2 White/Blue
3 ALS2 3 Orange/White
4 ALS3 4 White/Orange
5 ALS4 5 Green/White
6 ALS5 6 White/Green
7 - 7 Brown/White
8 - 8 White/Brown
9 GND 9 Grey/White
- - nc White/Grey
- - nc Blue/Yellow

Table 49 Signals on panel connector 23 (current-controlled ALS inputs)

98 Id:0900d805804ab823 DN70617303
Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)

Pin; Alarms; Alarm cable Alarm cable


CYV; CYV;
CPRJ45-A Connector 23 Pin in Connector Colour
panel, connec- (Voltage and 1
tor 23 current-controlled
EXT AL INPUT)
- - nc Yellow/Blue
- - nc Orange/Yellow
- - nc Yellow/Orange
- - nc Green/Yellow
- - nc Yellow/Green
- - 9 Connector hood Screen wire
Hood GND Connector hood Cable shield
Note
ALS = current-controlled external alarm input signal

Table 49 Signals on panel connector 23 (current-controlled ALS inputs) (Cont.)

Current-controlled external alarm input signals are connected from MDF to CPRJ45-A
panel by using the CYV cable.
One length of the cable is available (ID code presented): 20 m (C72239).
Six external current-controlled alarm inputs can be connected to the Flexi BSC by using
the CYV cable.

Connections to external alarm unit EXAU-A


A special lamp panel (External Alarm Unit EXAU-A) can be employed for the indication
of alarms.
Indicator lights have been connected to six incoming alarms of EXAU-A. In the EXAU-
A, a buzzer that can be connected to any alarm is available.
Using CNDE cable, the EXAU-A can be directly connected to D25-connector 22 of the
CPRJ45-A panel or through the digital distribution frame (DDF or cross connection) that
connects the alarm cables coming from the network element. When the alarms are
routed through the digital distribution frame (DDF) the CNDE cable is cut and the wires
are connected to the cross connection.
The complete CNDE cable is available in lengths 5, 10, 20 and 50 m. The maximum
distance between the EXAU-A panel and the network element equipment it is connected
to is 200 m (650ft.).
General requirements for external alarm cable CNDE are presented in the following
table.

Cable type: 12 pairs, twisted, shielded, cross section 0.4 mm2, Milliflex3
SH AWG26/8 pairs
Cable connector: 25-pin D connector (male/female)

Table 50 General requirements for external alarm cable CNDE

DN70617303 Id:0900d805804ab823 99
Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i

The EXAU-A has also a second D25 connector which makes is possible to chain several
alarm units so that the alarms can be displayed on more than one unit. See figure Instal-
lation of the EXAU-A; mounting on the wall, cabling, and setting the buzzer jumpers.
SW1 BUZZER SELECT

ON LS1
CAUTION 48V AL00 - 1
2 AL01 - 2 J1
F1
GND AL02 - 3 2
J1 AL03 - 4
AL04 - 5 3
AL05 - 6
7 SW2 SW1
134
3 8

140
PCB

Base
4

Cover

Alarm 1
AL00
Alarm 2 PCB
AL01
Alarm 3
1 AL02
Alarm 4
AL03
Alarm 5 Buzzer Reset
AL04
Alarm 6
AL05 Test
Silent Mode

5
DN068749

Figure 22 Installation of the EXAU-A; mounting on the wall, cabling, and setting the
buzzer jumpers
The colours of the alarm signals are shown in the following table.

Colour Position Signal Alarm


Red (1) Uppermost (AL00) Alarm 1
Yellow (2) (AL01) Alarm 2
Green (3) (AL02) Alarm 3
Red (4) (AL03) Alarm 4
Yellow (5) (AL04) Alarm 5
Blue (6) Lowermost (AL05) Alarm 6

100 Id:0900d805804ab823 DN70617303


Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)

6.3 VDU/LPT peripheral cabling (LPT/VDU interfaces)


The CPRJ45-A panel accommodates six RJ45 connectors for the following VDU and
LPT interfaces:
port 16 for LPT 0 (V.24)
port 17 for VDU 0 (V.24)
ports 24 and 25 for VDU1 (V.24) and VDU2 (V.24)
ports 26 and 27 for VDU2 (V.11) and LPT2 (V.11).
Each connector provides access to one interface of visual display unit / PC or printer
provided by the OMU (SERO-B). Pin configurations for connectors (16 and 17, and 24
to 27) providing the VDU/LPT interfaces are listed in Table V.24/V.11 cable connector
in the CPRJ45-A panel, pin configuration.

Pin Signal (V.24) Signal (V.11) Colour


1 DTR TxD+ Orange/White
2 TxD TxD- White/Orange
3 GND RxD+ Green/White
4 GND Blue/White
5 RxD White/Blue
6 DSR RxD- Green/White
7 CTS Brown/White
8 RTS White/Brown

Table 51 V.24/V.11 cable connector in the CPRJ45-A panel, pin configuration

The VDU can be connected to the CPRJ45-A panel by using the CNM cable, which is a
CNI-type cable provided with an RJ45 connector and a D9 connector. The LPT printer
can be connected to the CPRJ45-A panel using the CNP cable, which is a CNI-type
cable provided with an RJ45 connector and a D25 connector. See the following figure.

DN70617303 Id:0900d805804ab823 101


Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i

DE9F
CMN-cable L 1 (female)
RJ45F
(female)

B
A

B
VIEW B-B
1
2
VIEW A-A

RJ45F
CNP-cable L 3
2
(female)
C DB25M
(male)

C
1 1 POSITION NUMBER 1
VIEW C-C
2 UNC-40 male locking screws
USE CABLE OUTLET
3
OPTIMISING BUSHING
D D
CONNECTION CNM-cable CONNECTION CNP-cable

Pos. number Pos. number Pos. number Pos. number


Conn. RJ45F Wire colour Conn. DE9F
VIEW D-D
Conn. RJ45F Wire colour Conn. DB25M
1
1 (DTR) orange/white 6 (DSR) 1 (DTR) orange/white 6 (DSR)

2 (TxD) orange 2 RxD 2 (TxD) orange 3 (RxD)

3 (GND) white/green 5 (signal GND) 3 (GND) white/green 7 (signal GND)


4 (GND) blue 1 (GND) 4 (GND) blue 1 (GND)
5 (RxD) white/blue 3 (TxD) 5 (RxD) white/blue 2 (TxD)
6 (DSR) green 4 (DTR) 6 (DSR) green 20 (DTR)
7 (CTS) white/brown 7 (RTS) 7 (CTS) white/brown 4 (RTS)

8 (RTS) brown 8 (CTS) 8 (RTS) brown 5 (CTS)

Conn. hood shield Conn. hood Conn. hood shield Conn. hood
DN02237579

Figure 23 Peripheral cables; CNM for VDU and CNP for LPT
Recommended cable types for V.24/V.11 cables (CNI) are shown in the following table.

Cable type 4 pairs, twisted, shielded (S-FTP), Cat. 5 E, AWG24/26


Cable connector Shielded RJ45 modular connector (8-pole), Cat. 5 E.

Table 52 Recommended cable types for V.24/V.11 cables (CNI)

The cable and the connector meet the requirements of the UL 1459 standard or the
National Electrical Code ANSI/NFPA No.70. The connector also meets the require-
ments of the FCC Part 68.

102 Id:0900d805804ab823 DN70617303


Issue 1-0
Connector Panels and External Cables in Flexi BSC Roof panel with LAN, LPT/VDU, and synchronisation
and TCSM3i and alarm interfaces (CPRJ45-A)

6.4 External synchronisation cabling (EXT SYNC interfaces)


The CPRJ45-A panel accommodates two RJ45 connectors (18 SYMM0 and 19
SYMM1) for balanced (symmetric) synchronisation interfaces, and two BNC connectors
(20 ASYMM0 and 28 ASYMM1) for coaxial, unbalanced interfaces.

Balanced (symmetric)
The pin configuration for connectors 18 (SYMM0 CLS 0,1) and 19 (SYMM1 CLS 0,1),
and colours for CNI cable connector are presented in the following table.

Pin Connector 18 Connector 19 Colour (CNI) Remarks


(SYMM0CLS (SYMM1CLS 0,1)
0,1)
1 FS1A FS2A Orange/White Wire A of
external fre-
quency
standard FS1
or FS2
2 FS1B FS2B White/Orange Wire B of
external fre-
quency
standard FS1
or FS2
3 - - Green/White
Blue/White
White/Blue
Green/White
7 - - Brown/White
8 - - White/Brown
Connector RSG1 RSG2 Ground signal
hood
Notes
FS1A = Wire A of external frequency standard FS1
FS1B = Wire B of external frequency standard FS1
FS2A = Wire A of external frequency standard FS2
FS2B = Wire B of external frequency standard FS2
RSG1 = Ground signal
RSG2 = Ground signal

Table 53 The pin configuration for connectors 18 and 19

Recommended cable types for balanced synchronisation cable (CNI) are shown in the
following table.

Cable type: 4 pairs, twisted, shielded (S-FTP), Cat. 5 E, AWG24/26


Cable connector: Shielded RJ45 modular connector (8-pole), Cat. 5 E.

Table 54 Recommended cable types for synchronisation cables (CNI)

DN70617303 Id:0900d805804ab823 103


Issue 1-0
Roof panel with LAN, LPT/VDU, and synchronisation Connector Panels and External Cables in Flexi BSC
and alarm interfaces (CPRJ45-A) and TCSM3i

Unbalanced (asymmetric)
The pin configuration for connectors 20 and 28 is shown in the following table.

Pin Signal / Connector 20 / Signal / Connector 28 /


ASYMM0 CLS0,1 ASYMM1 CLS0,1
Centre wire FS1A FS2A
Cable sheath FS1B FS2B

Table 55 Pin configuration for connectors 20 and 28

104 Id:0900d805804ab823 DN70617303


Issue 1-0
Connector Panels and External Cables in Flexi BSC Cabling panel with grounding outlets (CPGO)
and TCSM3i

7 Cabling panel with grounding outlets (CPGO)


The cabling panel with grounding outlets (CPGO) is installed at site at the BSCC cabinet
top of the Flexi BSC. The CPGO is used for STM-1/OC-3 trunk cables and GigE
Ethernet interface cables.

CPGO

DN0626582

Figure 24 CPGO
The cables and the connectors meet the requirements of the UL 1459 standard or the
National Electrical Code ANSI/NFPA No.70 as well as the requirements of the FCC Part
68.
B

Dust 30 5
caps to LC DN70631285
connectors
Figure 25 Optical LC connectors, straight type
Main characteristics of optical cables and connectors are shown in the following tables.

Fibre cable material: 9/125 um singlemode fibre


Straight or angle connectors: Duplex LC, according to GR-326, IEC 60874

Table 56 Main characteristics of optical singlemode cables and connectors

Fibre cable material: 62.5/125 um multimode fibre


Straight or angle connectors: Duplex LC, according to GR-326, IEC 60874

Table 57 Main characteristics of optical multimode cables and connectors

For more information on the optical cables, see Requirement specifications for external
cables of M98 mechanics Flexi BSC product family and TCSM3i.

DN70617303 Id:0900d8058048f55e 105


Issue 1-0
Requirement specifications for external cables of M98 Connector Panels and External Cables in Flexi BSC
mechanics Flexi BSC and TCSM3i and TCSM3i

8 Requirement specifications for external


cables of M98 mechanics Flexi BSC and
TCSM3i

8.1 General requirements for connectors and cable materials


Connectors:
Connectors and hoods of the connectors must be shielded
1.25 mm, or 50 microinches (0.75 mm or 30 microinches, if 1.25 mm is not available)
gold plating on the contacts
UL94 V-0 materials

Cable material:
Shielded construction, screening effectiveness > 60 dB at 1GHz
AWG 26 conductors
Continuous pair twisting on the twisted pair cables
Operating temperature 0 to 80C
VW-1 materials

Optional:
Halogen free materials (IEC 332-1 or IEC 332-3)
Grey colour (RAL 7036, if available)

8.2 Requirements for specified coaxial cable assemblies

8.2.1 E1 coaxial unbalanced PCM cable assembly


Cable:
Multicoaxial cable (8 coax) with common braid
Impedance 75 3
Maximum attenuation < 9dB/100 m at 10 MHz
Nominal capacitance: < 66 pF/m
Conductor resistance: < 365 /km

Connectors:
Coaxial connectors: SMB/50 /straight type

8.2.2 Unbalanced (coaxial) external synchronisation cable assembly


(CKB)
Cable:
Coaxial (BT 3002)
Impedance 75 4
Attenuation: 4.4 dB/100 m at 5 MHz

106 Id:0900d805804f3fcb DN70617303


Issue 1-0
Connector Panels and External Cables in Flexi BSC Requirement specifications for external cables of M98
and TCSM3i mechanics Flexi BSC and TCSM3i

Capacitance: < 66 pF/m

Connectors:
BNC type

8.3 Requirements for specified twisted pair cable assemblies

8.3.1 10 Base-T /100 Base-TX / 1000Base-T/TX LAN cable assemblies (CNI


and cross-connected LAN cable)
Cable:
S-FTP
Category 5 E
Meets EIA/TIA 568-A standard

Connectors:
RJ45

8.3.2 T1 (E1) balanced PCM cable assembly (CNIS)


Cable:
Nominal impedance: 100 15
Attenuation: < 4 dB/100 m at 1 MHz
Resistance: Maximum 151 /km at 20C
Crosstalk attenuation: > 70 dB at 150 kHz

Connectors:
Shielded 8-pole plug RJ45

8.3.3 E1 balanced PCM cable assembly (CNIB)


Cable:
Nominal impedance: 120 15
Attenuation: < 4 dB/100 m at 1 MHz
Resistance: Maximum 151 /km at 20C
Crosstalk attenuation: > 70 dB at 150 kHz

Connectors:
Shielded 8-pole plug RJ45

8.3.4 E1 balanced PCM cable assembly (CNIA)


Cable:
Nominal impedance: 120 15
Attenuation: < 4 dB/100 m at 1 MHz
Resistance: Maximum 151 /km at 20C

DN70617303 Id:0900d805804f3fcb 107


Issue 1-0
Requirement specifications for external cables of M98 Connector Panels and External Cables in Flexi BSC
mechanics Flexi BSC and TCSM3i and TCSM3i

Crosstalk attenuation: > 70 dB at 150 kHz

Connectors:
Shielded 8-pole plug RJ45

8.3.5 Current and voltage-controlled alarm cable assembly (CNDC)


Cable:
See General requirements

Connectors:
25-pin D-subminiature connector at both ends of the cable

8.3.6 Alarm cable (CNDE)


Cable:
10-pair
double shielded (foil and copper braid)
halogen-free jacket
differential impedance 100
AWG 26 conductors

Connectors:
25-pole male D-connectors

8.3.7 Alarm cable (CYV)


Cable:
Milliflex3 SH AWG26/4 pairs

Connectors:
male 9-pin D-connector at one end of the cable

8.3.8 Alarm cable (CYR)


Cable:
See General requirements

Connectors:
25-pin D-subminiature connector at one end of the cable

8.3.9 Electrical performance requirements for X.25 cable assemblies


Cable:
Linear resistance of the conductor: 151 /km, maximum 20 C
Nominal impedance: 100 15
Attenuation: < 4 dB/100 m at 1 MHz

108 Id:0900d805804f3fcb DN70617303


Issue 1-0
Connector Panels and External Cables in Flexi BSC Requirement specifications for external cables of M98
and TCSM3i mechanics Flexi BSC and TCSM3i

Capacitance between cores: 60 pF/m nominal


Phase delay time: 5.4 ms/km at 1 MHz
Crosstalk attenuation: > 50 dB at 150 kHz

V.24 cable assemblies (CLSC)


Connectors:
25-pin D-subminiature connector
2HM connector

V.35 cable assembly (CLRD) - S11.5


Connectors:
V.35 connector
D25 connector

V.35 cable assembly (CLRC)- S10 and S11


Connectors:
V.35 connector
2HM connector

X.21 cable assemblies (CLTC)


Connectors:
15-pin D-subminiature connector
2 Hard Metric connector

8.3.10 Electrical performance requirements for optical LC cable assem-


blies (multimode cable)
Fibre cable material
62,5/125 m multi mode fibre
RoHS-compliance according to EU-directive
Attenuation 3.8 dB/km maximum at 850 nm wavelength, according to IEC 60793-1-
C1
Duplex type
Halogen free material, according to IEC 60754-1
Flammability UL VW-1 listed or UL94V-0 rated material
Fibre cables must be provided with a common secondary overall jacket, which is not
permitted to glide too loosely along fibre cables
Shape of cable jacket, circular, elliptical jacket can be used, if circular material is not
available
Cable outer diameter 6.6mm maximum
Minimum bending radius during installation 65 mm and in service 43mm, according
to IEC 60794-1-2E11A or similar standard
Crush resistance (briefly) > 500 N/cm, according to IEC 60794-1-E3
Crush resistance (continuous) > 100 N/cm
Orange jacket color, if orange is not available, gray color can be used
Operating temperature from 0 to 70C

DN70617303 Id:0900d805804f3fcb 109


Issue 1-0
Requirement specifications for external cables of M98 Connector Panels and External Cables in Flexi BSC
mechanics Flexi BSC and TCSM3i and TCSM3i

Connector 1 and connector 2


TIA/EIA 604-10A
All requirements are for one connector
Duplex LC, according to GR-326 and IEC 60874
RoHS-compliance according to EU-directive
Mating durability for 200 reconnects, insertion loss change < 0.2 dB
Insertion loss 0.5 dB maximum
SPC finish
Return loss > 20 dB
Flammability UL94V-0
Zirconia ferrule
Beige color
Dust caps included
Operating temperature from 0 to 70C
Efficiency of strain relief > 80N/termination

Cable support for LC connector 1


Flammability UL94 V-0
Straight flexible boot
RoHS-compliance according to EU-directive
Cable boot color gray/beige
Efficiency of strain relief > 50N/boot

Cable support for LC connector 2


Flammability UL94 V-0
90 angle boot
RoHS-compliance according to EU-directive
Maximum installation length 70 mm
Cable boot color gray/beige
Efficiency of strain relief: > 20N/boot
Design should allow rotation of cable support

8.3.11 Electrical performance requirements for optical LC cable assem-


blies (singlemode cable)
Cable material:
9/125 m single mode fibre
RoHS-compliance according to EU-directive
Cut-off wavelength < 1260 nm, according to IEC 60793-1-C7B
Attenuation (buffered fiber):
= 0,50 dB/km at 1310 nm wavelengths, according to IEC 60793-1-C10
= 0,40 dB/km at 1550 nm wavelengths, according to IEC 60793-1-C10
Cable must fulfill ITU-T G.652 for interface type STM-1 optical (ITU-T G.957, table 1)
Cable must fulfill ATM 155 Mb/s o Duplex type
Duplex type
Halogen free material, IEC 60754-1

110 Id:0900d805804f3fcb DN70617303


Issue 1-0
Connector Panels and External Cables in Flexi BSC Requirement specifications for external cables of M98
and TCSM3i mechanics Flexi BSC and TCSM3i

Flammability UL VW-1 or UL94V-0 rated cable material


Fibre cables must be provided with a common secondary overall jacket, which is not
permitted to glide too loosely along fibre cables
Shape of cable jacket circular, elliptical jacket can be used, if the circular material is
not available
Cable outer diameter 6.6 mm maximum
Minimum bending radius during installation, 65 mm and in service 43 mm, according
to IEC 60794-1-2E11A or similar standard
Crush resistance (briefly) > 500 N/cm, according to IEC 60794-1-E3
Crush resistance (continuous) > 100 N/cm
Yellow jacket color
Operating temperature from 0 to 70C

Connector 1 and connector 2


All requirements are for one connector
Duplex LC, according to GR-326 and IEC 60874
RoHS-compliance according to EU-directive
Mating durability for 200 reconnects, insertion loss change < 0.2 dB
Insertion loss < 0.3 dB
SPC finish
Return loss > 45 dB
Flammability UL94V-0
Zirconia ferrule
Blue color
Dust caps included
Operating temperature from 0 to 70C
Efficiency of strain relief > 80N

Cable supports for LC connector 1


Flammability UL94V-0
Straight flexible boot
RoHS-compliance according to EU-directive
Cable boot color gray/beige
Efficiency of strain relief > 50N/boot

Cable supports for LC connector 2


Flammability UL94V-0
90 angle boot
RoHS-compliance according to EU-directive
Maximum installation length 70 mm
Cable boot color gray/beige
Efficiency of strain relief > 20N/boot
Design should allow rotation of cable support

DN70617303 Id:0900d805804f3fcb 111


Issue 1-0