Sie sind auf Seite 1von 12

Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
Electricity
Calibration of DC voltage up to 220 mV 1.4 V (8 ) Fluke calibrator
measuring equipment 220 mV - 2.2 V 5.2 mV Model: 5720A, SN. 5530023
2.2 - 11 V 33 mV
11 - 22 V 0.04 mV
22 - 220 V 0.47 mV
220 - 1100 V 6.6 mV
Calibration of DC voltage sources 100 mV 0.8 V (2 ) Fluke multimeter
1V 5 V Model: 8508A, SN. 46738
10 V 0.07 mV
100 V 0.9 mV
1000 V 6.3 mV
Calibration of AC voltage 220 mV - 2.2 V (8 ) Fluke calibrator
measuring equipment (20 - 40) Hz 0.12 mV Model: 5720A, SN. 5530023
40 Hz - 20 kHz 0.12 mV
(20 - 50) kHz 2.9 mV
(50 - 100) kHz 2.9 mV
100 - 500 kHz 0.04 mV
2.2 - 22 V
(20 - 40) Hz 14 mV
40 Hz - 20 kHz 14 mV
(20 - 50) kHz 41 mV
(50 - 100) kHz 41 mV
220 - 1100 V
(20 - 60) Hz 0.09 V
60 Hz - 400 kHz 0.09 V
(400 - 1000) kHz 0.09 V
Calibration of AC voltage sources 100 mV (2 ) Fluke multimeter
55 Hz 0.02 mV Model: 8508A, SN. 46738
1 kHz 0.016 mV

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 1 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
30 kHz 0.06 mV
60 kHz 0.14 mV
100 kHz 0.18 mV
1V
55 Hz 0.13 mV
1 kHz 0.14 mV
30 kHz 0.52 mV
60 kHz 0.91 mV
100 kHz 0.91 mV
10 V
55 Hz 1.00 mV
1 kHz 1.2 mV
30 kHz 2.9 mV
60 kHz 8.00 mV
100 kHz 8.01 mV
100 V
55 Hz 19.0 mV
1 kHz 13.0 mV
30 kHz 28.0 mV
60 kHz 0.08 V
100 kHz 0.08 V
1000 V
55 Hz 0.18 V
1 kHz 0.18 V
10 kHz 0.15 V
30 kHz 0.30 V
Calibration of DC current up to 220 A 0.02 A (8 ) Fluke calibrator
measuring equipment 2.2 - 22 mA 0.7 A Model: 5720A, SN. 5530023
22 - 220 mA 12 A
220 mA - 2.2 A 0.23 mA

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 2 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
Calibration of DC current sources 100 A 0.012 A (2 ) Fluke multimeter
1 mA 0.04 A Model: 8508A, SN. 46738
10 mA 0.32 A
100 mA 6.2 A
1 A 0.23 mA
10 A 0.005 A
Calibration of AC current
Up to 22 mA (8 ) Fluke calibrator
measuring equipment
Model: 5720A, SN. 5530023
40 Hz - 1 kHz 3 A
(1 - 5) kHz 5.7 A
(5 - 10) kHz 0.03 mA
22 - 220 mA
40 Hz - 1 kHz 0.03 mA
(1 - 5) kHz 0.05 mA
(5 - 10) kHz 0.24 mA
220 mA - 2.2 A
40 Hz - 1 kHz 0.69 mA
(1 - 5) kHz 1.1 mA
(5 - 10) kHz 0.013 A
Calibration of AC current sources Fluke multimeter
100 A (2 )
Model: 8508A, SN. 46738
55 Hz 0.081 A
1 kHz 0.09 A
10 kHz 0.08 A
1 mA
55 Hz 0.57 A
1 kHz 0. 54 A
10 kHz 0.6 A

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 3 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
Calibration of AC current sources Fluke multimeter
10 mA (2 )
Model: 8508A, SN. 46738
55 Hz 0.006 mA
1 kHz 0.005 mA
10 kHz 0.005 mA
100 mA
55 Hz 0.05 mA
1 kHz mA 0.05
10 kHz mA 0.05
1 A
55 Hz 0.001 AC
1 kHz AC 0.001
10 kHz AC 0.002
10 A
55 Hz AC 0.002
1 kHz AC 0.05
10 kHz AC 0.04
Calibration of DC resistance 2 0.15 m (8 ) Fluke calibrator
measuring equipment 20 2.4 m Model: 5720A, SN. 5530023
200 14.2 m
2 k 0.1
20 k 0.2
200 k 2
2 M 38.5
20 M 0.98 k
100 M 11.9 k
Calibration of DC resistance 1 0.03 m (2 ) Fluke multimeter
sources 10 0.36 m Model: 8508A, SN. 46738

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 4 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
100 6.0 m
1 k 0.07
10 k 0.93
100 k 0.95
1 M 0.012 k
10 M 1.9 k
100 M 0.015 k
200 M 27 k
2000 M 1.18 M
Calibration of DC high voltage 0 - 40 kV 0.21 % (9 ) Digital multimeter
sources Model: 3114A , SN. 13436
Fluke high voltage probe
Calibration of DC high current 0 - 1000 A 1.1 A
Model: 80K-40, SN. 5605067
sources
Calibration of AC high current 0 - 800 A 0.85 A
sources (50/60 Hz)

Frequency
Calibration of frequency 1K Hz 1 GHz 0.02 Hz (10 ) Oscilloscope calibrator
Model: 9500B, SN. 273568112
With Active Head
SN. 294969006
Calibration of Oscilloscopes 1K Hz 1 GHz 5 sec (10 ) Oscilloscope calibrator
Model: 9500B, SN. 273568112
With Active Head
SN. 294969006
Calibration of tachometers 1000 150000 rpm 0.05 % (12 ) Electronic stroboscope
Model: 1538-A, SN. 76669
Universal Counter
Model: 5334B, SN. 2937A 07904

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 5 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used

Pressure

Calibration of pneumatic pressure (-12.5 to 0) psi 0.03 psi DKD-R 6-1:2003 Pressure transducers
gauge (0 to 500) psi 0.5 psi Model: 525A-PV4, SN. 591203
< 500 to 1000 psi 2 psi Model: 525A-P05, SN. 591291
Calibration of hydraulic pressure (0 to 3000) psi 4.4 psi Model: 525A-P07, SN. 590706
gauge < 3000 to 10000 psi 10 psi Model: 525A-P29, SN. 591293
Model: 700P31, SN. 89403106
Dead weight tester
Model: RPM4-E-DWT, SN. 1511
Balance

Calibration of non-automatic mg to > 220 g 10 mg 0.52 OIML R 76-1:2006 Class I weight sets
weighing instruments g to > 500 g 220 mg 0.94 SN. 96-092542, CN. 21-900-0004-001
(Permanent & on-site) g to > 2 kg 500 mg 3.5 CN. 21-900-0005-001, SN. 69089
SN. 69090, SN. 69091, SN. 69092
kg to > 5 kg 2 mg 8.5 SN. 69093, CN. 21-900-0006-001
kg to > 10 kg 5 mg 21 CN. 21-900-0007-001
kg to > 75 kg 10 g 0.16
kg to > 300 kg 75 g 13
Dimension

Calibration of gauge blocks up to 100 mm 0.2 m ISO 3650:1998 Gauge blocks comparator
SN. 8091
Gauge blocks set
Mo Model: 516-937-71,SN. 0103074 Grade K
Model: 350002, SN. 060817 Grade O
Calibration of calipers 0 - 150 mm 7 m ES 313:2008 Gauge blocks set
0 - 300 mm 8 m Model: 516-942, SN. 751260 Grade A
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 6 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
0 - 450 mm 10 m Individual gauge blocks
0 - 600 mm 12 m CN. 21-400-1007-0001
Calibration of dial indicator up to 10 mm 5 m ES 617:2008 Gauge blocks set
Model: 516-942, SN. 751260 Grade A
Measuring machine
Model: 305M, SN. 2625
Calibration of plug & ring gauge up to 300 mm 3 m DIN 13 part 14:1982 Measuring machine
Calibration of thread plug gauge up to 200 mm 3 m DIN 13 part 15:1982 Model: 305M, SN. 2625
Calibration of thread ring gauge with Standard setting ring
up to 125 mm 3 m SN. 41179, 41071
Calibration of universal measuring 150 250 mm 5 m ES 1567:2003 Gauge blocks set
machine Model: 516-942, SN. 751260 Grade A
Precision spirit level
CN. 21-120-0007-0001
Calibration of height gauge up to 600 mm 10 m ES 911:2003 Gauge blocks set
Model: 516-942, SN. 751260 Grade A
Individual gauge blocks
CN. 21-400-1007-0001
Surface plate
Model: Grade AA-lab, SN. 900617
Electronic indicator
Model: M406,SN. 100045 Grade AA
Steel square
CD. 21-820-0005-0004
Calibration of surface plate from (250 mm 400mm) 1.1 m DIN 876 Part 1:1984 Laser measurement system
up to (2000 mm3000mm) DIN 876 Part 2:1984 SN. 2532A02180
with Hamar laser
SN. 94112438

Calibration of micrometer outside 0 - 25 mm 4 m ES 163:2008 Gauge blocks set


25 - 50 mm 6 m ES 528:2008 Model: 516-942, SN. 751260 Grade A
50 - 75 mm 7 m Individual gauge blocks
CN. 21-400-1007-0001
75 - 100 mm 8 m
Surface plate
100 - 125 mm 9 m

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 7 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
125 - 150 mm 10 m Model: Grade AA-lab,SN. 900617
150 - 600 mm 12 m
Calibration of inside micrometer ES 163:2008
up to 600 mm 12 m Measuring machine
ES 528:2008
Calibration of depth micrometer up to 200 mm 10 m Model: 305M, SN. 2625
with Standard setting ring & Plug
SN. 41179, 41071
Optical flats
CD.21-640-0009-0001
Calibration of steel square angle up to 700 mm 5 m DIN 875:1981 Standard steel square
CD. 21-820-0005-004
Gauge blocks set
Model: 516-942, SN. 751260 Grade A

Calibration of coordinate up to 6000 mm 5 m ASME B 89.4.1:1997 Laser measurement system


measuring machine SN. 2532A02180
With Hamar laser
SN. 94112438

Temperature

Calibration of glass thermometer - 40 to 20 oC 0.14 oC ES 400:2005 Platinum resistance thermometer


20 to 100 oC 0.13 oC (1 ) Model: 5628, SN. 0461
(SPRT) with resistance bridge
100 to 220 oC 0.13 oC Model: 1575, SN. 4B054
220 to 400 oC 0.4 oC Water bath
Model: Neslab, SN. 1314135-1
Oil bath
Model: Fluke6331, SN. 2001811
Calibration bath
Model: 7380, SN. A56258
Sand bath
Model: FSB-3, CN. 21-181-0020-001

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 8 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
Calibration of thermocouples 30 to 1200 oC 0.71 oC ES 962:1993 Standard thermocouple type S
(K,T,J,S,R,E) (5 ) Model: 5650, SN. 9187
Platinum resistance thermometer
Model: 5628, SN. 0461
Digital thermometer
Model: 820, SN. T-233272
Model: 54II, SN. 14690038
Water bath
Model: Neslab, SN. 1314135-1
Oil bath
Model: Fluke6331, SN. 2001811
Dry well
SN.A59550
Calibration of digital thermocouple - 200 to 1100 oC 0.07 oC (3 ) Temperature calibrator
indicator Model: 525, SN. 9019004
(permanent &on-site) Model: 724, SN. 2007023
Digital thermometer
Model: 820, SN. T-234784, T-233272, T-
235237
Calibration of oven indicator 50 to 1100 oC 0.5 oC (2 ) Temperature calibrator
(permanent &on-site) Model: 525, SN. 9019004
Calibration of water bath indicator 20 to 90 oC 0.3 oC (4 ) Model: 724, SN. 2007023
Digital thermometer
(permanent &on-site)
Model: 820,SN. T-234784, T-233272, T-
Calibration of oil bath indicator 85 to 205 oC 0.3 oC 235237
(permanent &on-site) Digital themometer
Calibration of sand bath indicator 200 to 580 oC 0.4 oC Model: 54II, SN. 14690038
(permanent &on-site)
Calibration of temperature Source 0.02 oC (6 ) Fluke calibrator
calibrator Measure 0.03 oC Model: 5720A, SN. 5530023
Reference multimeter
Model: 8508A, SN. 46738

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 9 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
Calibration of platinum resistance 50 to 400 oC 0.2 oC (30 ) Standard platinum resistance
thermometer with digital indicator thermometer (SPRT)
Model. 5628, SN. 0461
Resistance bridge
Model. 1575, SN. 4B054
Reference multimeter
Model.8508A,SN. 46738
Water bath
Model: Neslab, SN. 1314135-1
Oil bath temperature
Model: Fluke6331, SN. 2001811
Sand bath temperature
Model: FSB-3,CN. 21-181-0020-0001
Low bath temperature
Model. 7380, SN. A56258
Force
Calibration of universal testing 7 - 60 ton 1.4 % ASTM E4:2007 Load cell
machine (tension & compression) Model: 41/9267-01-02, SN. 998919
Model: KTN-D, SN. 54993
Calibration of Rockwell hardness 20 - 60 HRC 1 HRC ISO 6508-2:2005 Reference Rockwell hardness blocks
tester Model: 61.97HRC, SN. 09R2129
Model: 44.73HRC, SN. 09R2127
Model: 26.45HRC,SN. 09R1684
Calibration of Brinell hardness 140 - 400 HB 2% ISO 6506-2:2005 Reference brinell hardness blocks
tester Model: 498 HBW, SN. 130221
Model: 319 HBW,SN. 130114
Model: 197 HBW,SN. 130665
Calibration of impact tester 40 400 J 3% EN 10045-pII:1991 Load cell
Model: KTN-D, SN. 54993
Calibers
Model: SCM-40, CN. 21-200-0005-006
Model: S-225, SN. 8279
Protractor
Model: C493B, CN. 21-120-0038-9009

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 10 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020
Calibration and Measurement Brief Description of
Measured Quantity Range
Capability* () Measurement and Equipment Used
Torque

Calibration of torque wrench CW 20 - 2500 Nm 1.25 % ISO 6789:2003 Torque transeducers


Model: TTC10, S.N.: 06098001 M-8125
Model: TTC11, S.N.: 06098001 M-8250
Model: TTC14, S.N.: 06098001 M-8200

(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
F09P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 11 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226
Ministry of Trade and Industry

Egyptian Accreditation Council


EGAC
Schedule of Accreditation
Issue to
Laboratories of Egyptian Tank Plant (ETP 200)
Industrial Zone, Abo Zaabal, Kalyobia, Egypt
Schedule No.: 297004B Issue No. (3): July 21, 2016 Revision No. (2): January 15, 2015 Valid to : March 31, 2020

Types of Tests / PropertiesMeasured / Range of


Materials / Products Tested Standard Specifications / Techniques Used / Main Devices
Measurements
Mechanical tests

Metallic materials Rockwell hardness test 23 - 63 HRC ASTM E 18:2007 Rockwell hardness tester
SN. 97214304
Brinell hardness test 200 - 400 HB ASTM E 10:2007a Brinell hardness tester
SN. 130114
Tension test 10 45 T ASTM E 8M:2004 Universal testing machine
SN. H0101

F10P15G
Kornish El-Maadi, Riad El-Maadi Tower 5.1 / Dec 2015
-1
Tel.: (202) 5275220/5275224/5275225/5275227
Page 12 of 12 (202) 5275220 / 5275224 / 5275225 /5275227 : 1 - Cairo - Egypt
( 202 ) 25275226 :
Fax: (202) 25275226

Das könnte Ihnen auch gefallen