Sie sind auf Seite 1von 7

Using AutoCad software, edit commands to construct the symmetrical shaded reinforced

concrete frame, shown below. The sketch illustrates the coordinates of each point is
required with question solution, Footing concrete cover (8.2cm) and wall concrete cover
(5cm). Suggest any dimensions not found.
.Suggest any dimensions not found. (Note: Dimensions or Text commands are not
required), start origin at (0,0) shown below at lower left corner.

0.6m 1.9m 0.3m


17.45
77.55
0.15m
0.15m
1.797m
2.0m

12@140mm
2.5m (2112mm) 2.5m

14 @ 120mm

12 @ 150mm
12 @ 150mm c/c
0.3m 0.95m
1.42m 0.30m G. L.

0.6m 0.4m 45
(1312mm)
0.1m (1312mm)
0.1m
Start point (0,0) 12 @ 150mm c/c 0.4m Reinforced concrete footing
0.9m 12 @ 150mm 0.1m Lean concrete
0.1m Compacted boulders (gravel)
2.0m
2.4m
:
rec
0.9,0
@2.5,0.1
Zoom
extents
Hatch
Pick point inside rectangle
Pattern Gravel ok
rec
0.9,0.1
@2.5,0.2
Hatch
Pick point inside rectangle
Pattern AR concrete ok
rec
1.1, 0.2 1

@2, 0.4

Offset
Specify offset distance: 0.082
Select object 2
Click on rectangle 1
Specify point on side
Click inside rectangle 1

Offset
Specify offset distance: 0.012
Select object
Click on rectangle 2
Specify point on side
Click inside rectangle 2

Bar center (x =0.9+0.2+0.082+0.012+0.006=1.2), (y=0.2+0.082+0.012+0.006=0.3)


Circle
0.1.2, 0.3
0.006
Select circle
Array

Distance between footing lower layer bars and upper layer


= 0.4-2*0.082-2*0.006 = 0.224
Select all lower circles of footing by dragging mouse pointer from left to right
copy
d

0, 0.224, 0
Bar center of lower corner bar of wall
X (0.9+0.2+0.082+.012+.006+5*0.15+ 0.075=2.025)
Y (0.2+ 0.082 + 0.012+0.006 =0.3 )

Circle
2.025, 0.3
0.006
Horizontal distance between lower circles of wall = 0.3-2*0.05-0.012 = 0.188
Select (click on) lower corner circle of wall
Copy
D
0.188, 0, 0
Line
0.9, 0.6
0.9, 2.5 or @2.5<90

Line
1.75, 0.6
1.95, 0.8

Select line
Mirror
Specify first point of mirror line
Click to draw vertical line then

rec
1.95, 0.8
@0.3, 2.5
rec
2, 0.294
@0.2, 3.006

Select two circles at lower edge of wall


Array

Line
1.42, 0.3
@0.3<0
@0.95<45
@0.3<90

Dowel
Reinforcement
Select dowel line
Mirror
Specify first point of mirror line
Click to draw vertical line then

Line (0, 3.3)


0, 3.3
17.45
77.55
@0.15< -17.45 0.15m
@0.45< 77.55
1.797m

@1.797 < -17.45 2.0m

3.3m

Start point (0,0)



Line
0, 3.3 0.6m 1.9m
@0.6 < 77.55 (0, 3.3) 17.45

@1.9 < -17.55 77.55


0.15m
1.797m
2.0m

3.3m

Select shaded inclined roof lines


Start point (0,0)
Mirror
Specify first point of mirror line
Click to draw vertical line then

0.6m 1.9m

Line
(0, 3.3) 17.45
77.55
2.1, -1 0.15m
2.1, 3 1.797m
2.0m
Select this line
Open Format menu
3.3m
Select Linetype command
Click on Load command
Select Dot line
Change scale factor
From properties menu bar
Click by Bylayer lineype
Select dot line
Start point (0,0)