Sie sind auf Seite 1von 1

Your Single Source for

1 2 3 4 5 6 7 8 9 10 Quality System Design


& Documentation Services
C ass
SYMBOL LEGEND A ssociates
A,C,E DOOR LOCATION # 1 A,C,D DOOR LOCATION # 11
JB JUNCTION BOX
JB JB D esign G roup, I nc.
C,E C,D
IR
REQUEST TO EXIT TO LAN/WAN DATA JACK (BY OTHERS) [1 CR] D C,D B,D B,D A [1 CR] C,D B,D B,D A 40 North Avenue, Webster, New York 14580-3056
INFRARED DETECTOR [LOCK POWER] [LOCK POWER] Phone: 585 216-1088 Fax: 585 216-1093
A CAT-5 JUMPER [SOUNDER POWER]
PT PT
5-A-1
PT PT A www.cassdesigngroup.com
DC DOOR CONTACT - N.C.
J 3-A-1
LS CB CB EM CR CB CB EM CR

INSTALLATION REQUIREMENTS. DIRECT ANY COMMENTS TO [DEALER NAME].


5) INSTALLING CONTRACTOR TO VERIFY ALL DEVICE COUNTS, LOCATIONS AND
2) COORDINATE EQUIPMENT INSTALLATION AS REQUIRED WITH ALL TRADES.

4) FOR EQUIPMENT LOCATIONS REFER TO ASSOCIATED BUILDING FLOOR PLANS.


INSTALLATION MANUALS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
3) DRAWINGS ARE FOR REFERENCE USE ONLY - REFER TO ASSOCIATED EQUIPMENT
1) INSTALLATION METHODS TO MEET ALL APPLICABLE CODES AND SPECIFICATIONS.
24 VDC ELECTRIC STRIKE
ES [REX+LPB] [REX+LPB] (DOUBLE) (IN) [REX+LPB] [REX+LPB] (DOUBLE) (IN)
(FAIL SECURE) [DSM] [DSM]
CR CARD READER (PR-THIN) A,C,D DOOR LOCATION # 7 A,C,E DOOR LOCATION # 2 A,C,D
B DOOR LOCATION # 12
CRASHBAR N.C. & N.O. DB (4-A-1)
CB JB JB JB
(REX & LPB) C,D C,E B C,D
J J J J J
[1 CR] B B,D A [1 CR] D C,D B,D B,D A DR (4-A-2) - DOOR # 11 [1 CR] C,D B,D B,D A
PT POWER TRANSFER HINGE
[LOCK POWER] [LOCK POWER] [LOCK POWER]
PT PT PT PT PT
ACCESS 1-B-1 ACCESS [SOUNDER POWER] ACCESS B ACCESS 5-A-2
24 VDC DOUBLE MAGNETIC
EM CONTROL CONTROL 3-A-2 CONTROL 9B
DB (4-A-3) CONTROL
LOCK w/DSM DC CL CR LS CB CB EM CR CB CB EM CR

GENERAL NOTES
PANEL PANEL PANEL B PANEL
LS 24 VDC LOCAL SOUNDER (FAILSECURE) (IN) [REX+LPB] [REX+LPB] (DOUBLE) (IN) [REX+LPB] [REX+LPB] (DOUBLE) (IN)
# 1 [REX] # 3 [DSM] # 4 DB (4-A-4) # 5 [DSM]
B IC INTERCOM STATION
D
IC R2
D
R2 R2
D
IN B
D
R2 R2 B
A,C,D DOOR LOCATION # 8 A,C,E DOOR LOCATION # 3 DR (4-A-5) - DOOR # 1
A,C,D DOOR LOCATION # 13
3B,4D 3B,3E,F 3B,3D,F
DR ( ) DOOR RELEASE BUTTON
JB JB T
B JB
QTY # ( ) = DOOR(S) CONTROLLED C,D C,E DR (4-A-6) - DOOR # 2 C,D
[1 CR] B B,D A [1 CR] C B D A [1 CR] B B,D A
24 VDC CYLINDRICAL LOCKSET AUX [LOCK POWER] AUX [LOCK POWER] AUX [LOCK POWER]
CL
PT B PT
w/REX (FAIL SECURE) POWER 1-B-2 POWER [AUX POWER FOR REX] DR (4-A-7) - DOOR # 11 POWER 5-B-1
TO 120 VAC
24 VDC MORTISED LOCKSET SUPPLY SUPPLY 3-B-1 SUPPLY
ML
DC CL CR IR DC ES CR B DC ML CR
w/REX (FAIL SECURE) 2B,2D (FAILSECURE) (IN) [REX] (FAILSECURE) (IN) DR (4-A-8) - DOOR # 12 (FAILSECURE) (IN)
DB DURESS BUTTON [REX] [REX]
T T B T
B
T PLUG-IN TRANSFORMER DC (1-B-5) - DOOR # 5
A,C,F DOOR LOCATION # 4 DC DC (4-A-9) A,C,F DOOR LOCATION # 22
B JB JB
CS-## CCTV CAMERA STATION
C TO 120 VAC DC (1-B-6) - DOOR # 10 TO 120 VAC
C,F
[1 CR] D C B D A TO 120 VAC
C,F
[1 CR] D C B D A C
CCTV
CCTV EQUIPMENT RACK D [LOCK POWER] [LOCK POWER]
RACK [AUX POWER FOR REX] [AUX POWER FOR REX]
LS (1-B-1 AUX) - DOOR # 5
[SOUNDER POWER] [SOUNDER POWER]
AUX LS IR DC ES CR LS IR DC ES CR
AUXILIARY POWER SUPPLY D
PS 3-B-2 5-B-2
LS (1-B-2 AUX) - DOOR # 10 [REX] (FAILSECURE) (IN) [REX] (FAILSECURE) (IN)
IC JB INTERCOM SYSTEM JUNCTION BOX J J
6B
ICM # INTERCOM MASTER STATION

B B B B B B B
21"
MON CCTV MONITOR DC (2-A-1) - DOOR # 6
DR DR DB DB DB DB
ACCESS B
(3-A-5) (3-A-6) (3-A-7) (3-B-5) (3-B-6) (3-B-7)
(# - X -# ) INPUT POINT NUMBER CONTROL 6A,4B,2C
DC (2-A-2) - DOOR # 9
DOOR # 1 DOOR # 2
D [# - X -# ] OUTPUT POINT NUMBER
PANEL 2C D
# 2 TO REMOTE VIDEO UNIT OUTPUTS (2-A-3 THRU -6)
D
IN OUT (VIA CUSTOM RELAY INTERFACE)
# - X -# A
TO VCR STATUS (2-A-7 THRU -9) A,C,F DOOR LOCATION # 14 A,C,E DOOR LOCATION # 18
T
B
(VIA CUSTOM RELAY INTERFACE) JB JB

CUSTOMER ADDRESS
BOARD READER NUMBER
TO VCR ALARM IN [2-A-AUX 1] C,F C,E
BOARD POSITION (A OR B)

STREET ADDRESS
[1 CR] D C B D A [1 CR] D C,D B,D B,D A

CUSTOMER NAME
ACCESS CONTROL PANEL NUMBER

CITY, STATE ZIP

CITY, STATE ZIP


3A,B [LOCK POWER] [LOCK POWER]

SITE LOCATION

DEALER NAME
(2-A-10) PT PT
TO 120 VAC TO CCTV MULTIPLEXER [AUX POWER FOR REX] [SOUNDER POWER]

FAX
ACCESS [2-B-1 THRU -16]
CONTROL [SOUNDER POWER] 8-A-1
2A LS IR DC ES CR LS CB CB EM CR
PANEL
TO INTERCOM INTERFACE (2-A-11 THRU -16) 6-A-1
## [REX] (FAILSECURE) (IN) [REX+LPB] [REX+LPB] (DOUBLE) (IN)
XX XX [DSM]
B

PHONE
A,C,E DOOR LOCATION # 15 DB (7-A-1) A,C,E DOOR LOCATION # 19
E POSITION "B" BOARD TYPE B E
JB JB
POSITION "A" BOARD TYPE DR (7-A-2) - DOOR # 17
J J C,E J J J C,E
[1 CR] C B D A [1 CR] C B D A
B
REX = REQUEST TO EXIT [LOCK POWER] [LOCK POWER]
ACCESS [AUX POWER FOR REX] ACCESS
DR (7-A-3) - DOOR # 18 ACCESS [AUX POWER FOR REX]
LPB = LOCK POWER BREAKING
CONTROL 6-A-2 CONTROL 7B B CONTROL 8-A-2
DSM = DOOR STATUS MONITORING IR DC ES CR IR DC ES CR
PANEL PANEL DB (7-A-4) PANEL
[REX] (FAILSECURE) (IN) [REX] (FAILSECURE) (IN)
# 6 # 7 B # 8
D D D
R2 R2 IN DB (7-A-5) R2 R2
SYSTEM LOW VOLTAGE CABLE TYPES A,C,E DOOR LOCATION # 16 A,C,E DOOR LOCATION # 20
3B,3E,F B 3B,3E,F
ALL CABLES SUBJECT TO APPROVAL PRIOR TO INSTALLATION BY JB T DB (7-A-6) JB

AUTHORITY HAVING JURISDICTION (AHJ). DO NOT SUBSTITUTE SPECIFIED C,E


[1 CR] C B D A B
C,E
[1 CR] C B D A
CABLES WITHOUT PRIOR APPROVAL BY [DEALER NAME] AND THE AHJ. AUX [LOCK POWER] DB (7-A-7) AUX [LOCK POWER]
F POWER [AUX POWER FOR REX] POWER [AUX POWER FOR REX] F
(ALL CABLES MANUFACTURED BY WEST PENN WIRE/CDT) SUPPLY 6-B-1
TO 120 VAC
SUPPLY 8-B-1
IR DC ES CR IR DC ES CR
SYM GENERAL USAGE NON-PLENUM PLENUM CABLE DESCRIPTION [REX] (FAILSECURE) (IN) [REX] (FAILSECURE) (IN)
TO CENTRAL POINT GROUND
A READER 3270 253270B 6 COND., 22 AWG, STRANDED, SHIELDED T (TYPICAL) T
CAD FILE:
B ALARM POINT 291 25291B 2 COND., 22 AWG, STRANDED, SHIELDED
A,C,E DOOR LOCATION # 17 A,C,F DOOR LOCATION # 21
CAD_GROUP_RSR-01
C ALARM POINTS 3241 253241B JB JB
4 COND., 22 AWG, STRANDED, SHIELDED DATE: REVISION:
C,E C,F
D POWER/DOOR 293 25293B 2 COND., 18 AWG, STRANDED, SHIELDED TO 120 VAC [1 CR] D C,D B,D B,D A TO 120 VAC [1 CR] D C B D A 20MAR06 SAMPLE
[LOCK POWER] [LOCK POWER]
E POWER/DOOR 3244 253244B 4 COND., 18 AWG, STRANDED, SHIELDED [SOUNDER POWER] PT PT
[AUX POWER FOR REX] DRAWING TITLE:

[SOUNDER POWER]
F POWER/DOOR 3021 T-B-D 6 COND., 18 AWG, STRANDED, SHIELDED 6-B-2
LS CB CB EM CR
8-B-2
LS IR DC ES CR RISER DIAGRAM
G STATUS/REX PIR 3270 253270B 6 COND., 22 AWG, STRANDED, SHIELDED [REX+LPB] [REX+LPB] (DOUBLE)
[DSM]
(IN) [REX] (FAILSECURE) (IN) ACCESS
G H COMMUNICATIONS D2401 D252401
1 PAIR, 24 AWG, STRANDED, SHIELDED G CONTROL
LOW CAP. (< 20.3 pF/FT), 120 OHM IMP. 4B 4B
SYSTEM
2 PAIR, 24 AWG, STRANDED, SHIELDED
J COMMUNICATIONS D2402 D252402
LOW CAP. (< 20.3 pF/FT), 120 OHM IMP. B B B B B B B B

K KEYPAD 3283 T-B-D 12 COND., 18 AWG, STRANDED, SHIELDED DB

(6-A-5)
DB

(6-A-6)
DB

(6-B-5)
DB

(6-B-6)
DB

(8-A-5)
DB

(8-A-6)
DB

(8-B-5)
DB

(8-B-6)
RSR - 01
1 2 3 4 5 6 7 8 9 10 SHEET______ OF ______