GENERAL NOTES
PANEL PANEL PANEL B PANEL
LS 24 VDC LOCAL SOUNDER (FAILSECURE) (IN) [REX+LPB] [REX+LPB] (DOUBLE) (IN) [REX+LPB] [REX+LPB] (DOUBLE) (IN)
# 1 [REX] # 3 [DSM] # 4 DB (4-A-4) # 5 [DSM]
B IC INTERCOM STATION
D
IC R2
D
R2 R2
D
IN B
D
R2 R2 B
A,C,D DOOR LOCATION # 8 A,C,E DOOR LOCATION # 3 DR (4-A-5) - DOOR # 1
A,C,D DOOR LOCATION # 13
3B,4D 3B,3E,F 3B,3D,F
DR ( ) DOOR RELEASE BUTTON
JB JB T
B JB
QTY # ( ) = DOOR(S) CONTROLLED C,D C,E DR (4-A-6) - DOOR # 2 C,D
[1 CR] B B,D A [1 CR] C B D A [1 CR] B B,D A
24 VDC CYLINDRICAL LOCKSET AUX [LOCK POWER] AUX [LOCK POWER] AUX [LOCK POWER]
CL
PT B PT
w/REX (FAIL SECURE) POWER 1-B-2 POWER [AUX POWER FOR REX] DR (4-A-7) - DOOR # 11 POWER 5-B-1
TO 120 VAC
24 VDC MORTISED LOCKSET SUPPLY SUPPLY 3-B-1 SUPPLY
ML
DC CL CR IR DC ES CR B DC ML CR
w/REX (FAIL SECURE) 2B,2D (FAILSECURE) (IN) [REX] (FAILSECURE) (IN) DR (4-A-8) - DOOR # 12 (FAILSECURE) (IN)
DB DURESS BUTTON [REX] [REX]
T T B T
B
T PLUG-IN TRANSFORMER DC (1-B-5) - DOOR # 5
A,C,F DOOR LOCATION # 4 DC DC (4-A-9) A,C,F DOOR LOCATION # 22
B JB JB
CS-## CCTV CAMERA STATION
C TO 120 VAC DC (1-B-6) - DOOR # 10 TO 120 VAC
C,F
[1 CR] D C B D A TO 120 VAC
C,F
[1 CR] D C B D A C
CCTV
CCTV EQUIPMENT RACK D [LOCK POWER] [LOCK POWER]
RACK [AUX POWER FOR REX] [AUX POWER FOR REX]
LS (1-B-1 AUX) - DOOR # 5
[SOUNDER POWER] [SOUNDER POWER]
AUX LS IR DC ES CR LS IR DC ES CR
AUXILIARY POWER SUPPLY D
PS 3-B-2 5-B-2
LS (1-B-2 AUX) - DOOR # 10 [REX] (FAILSECURE) (IN) [REX] (FAILSECURE) (IN)
IC JB INTERCOM SYSTEM JUNCTION BOX J J
6B
ICM # INTERCOM MASTER STATION
B B B B B B B
21"
MON CCTV MONITOR DC (2-A-1) - DOOR # 6
DR DR DB DB DB DB
ACCESS B
(3-A-5) (3-A-6) (3-A-7) (3-B-5) (3-B-6) (3-B-7)
(# - X -# ) INPUT POINT NUMBER CONTROL 6A,4B,2C
DC (2-A-2) - DOOR # 9
DOOR # 1 DOOR # 2
D [# - X -# ] OUTPUT POINT NUMBER
PANEL 2C D
# 2 TO REMOTE VIDEO UNIT OUTPUTS (2-A-3 THRU -6)
D
IN OUT (VIA CUSTOM RELAY INTERFACE)
# - X -# A
TO VCR STATUS (2-A-7 THRU -9) A,C,F DOOR LOCATION # 14 A,C,E DOOR LOCATION # 18
T
B
(VIA CUSTOM RELAY INTERFACE) JB JB
CUSTOMER ADDRESS
BOARD READER NUMBER
TO VCR ALARM IN [2-A-AUX 1] C,F C,E
BOARD POSITION (A OR B)
STREET ADDRESS
[1 CR] D C B D A [1 CR] D C,D B,D B,D A
CUSTOMER NAME
ACCESS CONTROL PANEL NUMBER
SITE LOCATION
DEALER NAME
(2-A-10) PT PT
TO 120 VAC TO CCTV MULTIPLEXER [AUX POWER FOR REX] [SOUNDER POWER]
FAX
ACCESS [2-B-1 THRU -16]
CONTROL [SOUNDER POWER] 8-A-1
2A LS IR DC ES CR LS CB CB EM CR
PANEL
TO INTERCOM INTERFACE (2-A-11 THRU -16) 6-A-1
## [REX] (FAILSECURE) (IN) [REX+LPB] [REX+LPB] (DOUBLE) (IN)
XX XX [DSM]
B
PHONE
A,C,E DOOR LOCATION # 15 DB (7-A-1) A,C,E DOOR LOCATION # 19
E POSITION "B" BOARD TYPE B E
JB JB
POSITION "A" BOARD TYPE DR (7-A-2) - DOOR # 17
J J C,E J J J C,E
[1 CR] C B D A [1 CR] C B D A
B
REX = REQUEST TO EXIT [LOCK POWER] [LOCK POWER]
ACCESS [AUX POWER FOR REX] ACCESS
DR (7-A-3) - DOOR # 18 ACCESS [AUX POWER FOR REX]
LPB = LOCK POWER BREAKING
CONTROL 6-A-2 CONTROL 7B B CONTROL 8-A-2
DSM = DOOR STATUS MONITORING IR DC ES CR IR DC ES CR
PANEL PANEL DB (7-A-4) PANEL
[REX] (FAILSECURE) (IN) [REX] (FAILSECURE) (IN)
# 6 # 7 B # 8
D D D
R2 R2 IN DB (7-A-5) R2 R2
SYSTEM LOW VOLTAGE CABLE TYPES A,C,E DOOR LOCATION # 16 A,C,E DOOR LOCATION # 20
3B,3E,F B 3B,3E,F
ALL CABLES SUBJECT TO APPROVAL PRIOR TO INSTALLATION BY JB T DB (7-A-6) JB
[SOUNDER POWER]
F POWER/DOOR 3021 T-B-D 6 COND., 18 AWG, STRANDED, SHIELDED 6-B-2
LS CB CB EM CR
8-B-2
LS IR DC ES CR RISER DIAGRAM
G STATUS/REX PIR 3270 253270B 6 COND., 22 AWG, STRANDED, SHIELDED [REX+LPB] [REX+LPB] (DOUBLE)
[DSM]
(IN) [REX] (FAILSECURE) (IN) ACCESS
G H COMMUNICATIONS D2401 D252401
1 PAIR, 24 AWG, STRANDED, SHIELDED G CONTROL
LOW CAP. (< 20.3 pF/FT), 120 OHM IMP. 4B 4B
SYSTEM
2 PAIR, 24 AWG, STRANDED, SHIELDED
J COMMUNICATIONS D2402 D252402
LOW CAP. (< 20.3 pF/FT), 120 OHM IMP. B B B B B B B B
(6-A-5)
DB
(6-A-6)
DB
(6-B-5)
DB
(6-B-6)
DB
(8-A-5)
DB
(8-A-6)
DB
(8-B-5)
DB
(8-B-6)
RSR - 01
1 2 3 4 5 6 7 8 9 10 SHEET______ OF ______