the HV disconnector
As the safety device at the heart of each substation,
the disconnector must:
c preserve the insulation of the networks 2 parts, even in the case of
exceptional events (earthquakes, short-circuits, operation over-voltages,
lightning) due to the network or to weather conditions
c be capable of operating in the most extreme environmental conditions.
Its dependability is thus primordial, only a specialist can guarantee you this.
The range is the largest on the market: 7 types of devices from 36 to
800 kV and from 1250 to 6300 A, not counting occasional adaptations.
Trustworthy technology
Switchgear generally conforms to IEC standards. Some versions are also
ANSI compliant and adaptations to other standards are possible.
Conductive materials
c Aluminium: castings and active parts.
c Bare or silver-plated copper for contacts and HV terminals.
36 kV c c c
72-100 kV c c c c
123 kV c c c c
145-170 kV c c c c c
245 kV c c c c c
300-420-550 kV c c c c c
800 kV c c
rated current 4000 4000 4000 4000 4000 6300
up to
short-circuit current 50 kA/3 sec 75 kA/3 sec 63 kA/3 sec 63 kA/3 sec 63 kA/3 sec 75 kA/3 sec
up to
advantages c economical c reduced phase c ultra compact c the most c reduced phase c reduced phase
and versatile to phase clearance device compact of all to phase to phase clearance
c the most sold c sturdy disconnectors clearance and vertical
in the world (forces on c high precision dimensions
terminals, mechanics c low operating
short-circuit, ice) c high connection time
latitude c high precision
mechanics
disadvantages c high phase to c higher costs c high vertical
phase clearance and required dimensions in
and limited forces torque than centre open position
on terminals break disconnector
Performances that can be improved upon request.
Ice thickness up to Protection of materials Earthquake behaviour IP 55 protection and Mechanical tests up
20 mm operation up to in harsh environments as in South American 50C under hot and to 10 000 operations /
- 50C standards windy environments 1 million oscillations
5
Continued quality service serves
leading edge R&D technology
Coelme and Egic, as recognised disconnector
designers, have entered into a long lasting period
of innovative dynamics that allows them to design
disconnectors that are less and less costly.
Colombia EPM
Isa
Philippines NPC
Meralco
Thailand EGAT
MEA
PEA
Vietnam EVN
Ecuador Inecel
Mexico CFE
LyFC
Protmex
Africa
Uruguay UTE
Algeria Sonelgaz
Venezuela Cadafe
Edelca Burundi Rseau
Electrique Australia SECV
Congo Rseau OEC
Electrique ECNSW
Morocco ONE - RAD
Contractors
South BPC
Africa Austria VA Tech. Elin Korea Hyosung
France Cegelec Hyundai
Tunisia STEG
Spie Lucky Goldstar
Tanzania Rseau Norelec (LGEN-LGIS)
Electrique Alstom Samsung Corp
Zaire Rseau Germany ABB Spain Abengoa
Electrique Siemens Elecnor
Foster Wheeler
Argentina SADE Isolux
Italy Ansaldo Great VA Tech.
Japan Mitsubishi Britain Reyrolle
Heavy Ireland ESB-ESBI
Industries (MHI)
United Bechtel
Mexico Grupo Tres States Fluor D.
Members of group
COELME EGIC As standards, specifications and designs change from time to This document has been
Via G. Galilei, 1/2 BP 6 time, please ask for confirmation of the information given in printed on ecological paper
30036 S.Maria di Sala - VE 86, chemin de la Mouche this publication.
Italia 69563 St-Genis-Laval Cedex
Tel.: +39 041 486022 France
Fax: +39 041 486909 Tel.: +33 4 72 66 20 70 Designed by: Insign studio
Email: coelme@coelme.it Fax: +33 4 72 39 08 65 Printed by:
www.coelme.it Email: egic@egic.fr
www.egic.fr
SHVED199056EN
ART. 028381 02/ 2002