HFA30PA60C
HEXFRED TM
Ultrafast, Soft Recovery Diode
Features VR = 600V
2
Ultrafast Recovery VF(typ.)* = 1.2V
Ultrasoft Recovery IF(AV) = 15A
Very Low IRRM
Very Low Qrr Qrr (typ.)= 80nC
Specified at Operating Conditions IRRM (typ.) = 4.0A
Benefits trr(typ.) = 19ns
Reduced RFI and EMI 1 3
Reduced Power Loss in Diode and Switching di(rec)M/dt (typ.)* = 160A/s
Transistor
Higher Frequency Operation
Reduced Snubbing
Reduced Parts Count
Description
International Rectifier's HFA30PA60C is a state of the art center tap ultra fast
recovery diode. Employing the latest in epitaxial construction and advanced
processing techniques it features a superb combination of characteristics which
result in performance which is unsurpassed by any rectifier previously available.
TO-247AC
With basic ratings of 600 volts and 15 amps per Leg continuous current, the
HFA30PA60C is especially well suited for use as the companion diode for IGBTs
and MOSFETs. In addition to ultra fast recovery time, the HEXFRED product
line features extremely low values of peak recovery current (IRRM) and does not
exhibit any tendency to "snap-off" during the tb portion of recovery. The
HEXFRED features combine to offer designers a rectifier with lower noise and
significantly lower switching losses in both the diode and the switching transistor.
These HEXFRED advantages can help to significantly reduce snubbing,
component count and heatsink sizes. The HEXFRED HFA30PA60C is ideally
suited for applications in power supplies and power conversion systems (such
as inverters), motor drives, and many other similar applications where high
speed, high efficiency is needed.
* 125C
www.irf.com 1
HFA30PA60C
Bulletin PD -2.336 rev. C 05/01
2 www.irf.com
HFA30PA60C
Bulletin PD -2.336 rev. C 05/01
100 10000
TJ = 150C
100
TJ = 125C
10
Instantaneous Forward Current - IF (A)
0.1
TJ = 150C TJ = 25C
A
0.01
TJ = 125C
10 0 100 200 300 400 500 600
TJ = 25C Reverse Voltage - V R (V)
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage, (per Leg)
100
A
Junction Capacitance -CT (pF)
TJ = 25C
A
1
1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4
ForwardVoltage
Forward VoltageDrop
Drop- -VVFM (V)
FM(V)
A
Fig. 1 - Maximum Forward Voltage Drop 10
0 100 200 300 400 500 600
vs. Instantaneous Forward Current,
Reverse Voltage - V R (V)
(per Leg)
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage, (per Leg)
10
Thermal Response (Z thJC )
1 D = 0.50
0.20
0.10
P DM
0.05
0.1
t1
0.02
0.01 t2
Notes:
1. Duty factor D = t 1 / t 2
2. Peak TJ = P DM x Z thJC + TC
0.01
0.00001 0.0001 0.001 0.01 0.1 1
t1 , Rectangular Pulse Duration (sec)
www.irf.com 3
HFA30PA60C
Bulletin PD -2.336 rev. C 05/01
100 25
I F = 30A VR = 200V
TJ = 125C
I F = 15A TJ = 25C
I F = 5.0A
80 20
I F = 30A
I F = 15A
I F = 5.0A
trr- (ns)
60 15
Irr- ( A)
40 10
20 5
VR = 200V
TJ = 125C
TJ = 25C
A A
0 0
100 1000 100 1000
di f /dt - (A/s) di f /dt - (A/s)
Fig. 5 - Typical Reverse Recovery Time vs. Fig. 6 - Typical Recovery Current vs. dif/dt,
dif/dt, (per Leg) (per Leg)
800 10000
VR = 200V VR = 200V
TJ = 125C TJ = 125C
TJ = 25C TJ = 25C
600
I F = 30A
I F = 15A
di (rec) M/dt- (A /s)
I F = 30A
IF = 5.0A
Qrr- (nC)
I F = 15A
400 1000
I F = 5.0A
200
A A
0 100
100 1000 100 1000
di f /dt - (A/s) di f /dt - (A/s)
Fig. 7 - Typical Stored Charge vs. dif/dt, Fig. 8 - Typical di(rec)M/dt vs. dif/dt,
(per Leg) (per Leg)
4 www.irf.com
HFA30PA60C
Bulletin PD -2.336 rev. C 05/01
t rr
IF
ta tb
0
REVERSE RECOVERY CIRCUIT
4
Q rr
VR = 200V 2
I RRM 0.5 I RRM
di(rec)M/dt 5
0.01
0.75 I RRM
L = 70H
D.U.T.
1 di f /dt
1. dif/dt - Rate of change of current 4. Qrr - Area under curve defined by trr
D through zero crossing and IRRM
dif/dt
ADJUST trr X IRRM
G IRFP250
2. IRRM - Peak reverse recovery current Qrr =
2
S 3. trr - Reverse recovery time measured
from zero crossing point of negative 5. di(rec)M/dt - Peak rate of change of
going IF to point where a line passing current during tb portion of trr
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
Fig. 9 - Reverse Recovery Parameter Test Fig. 10 - Reverse Recovery Waveform and
Circuit Definitions
Device Code
HF A 30 PA 60 C
1 2 3 4 5 6
1 - Hexfred Family
2 - Process Designator A = subs. elec. irrad.
B = subs. Platinum
3 - Current Rating (30 = 30A)
4 - Package Outline (PA = TO-247, 3 pins)
5 - Voltage Rating (60 = 600V)
6 - Configuration (C = Center Tap Common Cathode)
www.irf.com 5
HFA30PA60C
Bulletin PD -2.336 rev. C 05/01
Outline Table
3. 65 (0 .14 4)
15 .90 (0 .626 ) DIA. 5. 30 (0 .20 9)
3. 55 (0 .13 9) 4.70 ( 0.185)
15 .30 (0 .602 ) 2.5 ( 0.098)
1.5 ( 0.059)
5. 70 (0 .22 5)
5.30 ( 0.208) 2
20 .30 (0 .800 )
19 .70 (0 .775 ) 5.50 ( 0.217)
4. 50 (0 .17 7)
1 2 3 (2 PLCS.)
14. 80 ( 0.583)
14 .20 (0 .559 ) 4. 30 (0 .17 0) 1 3
3. 70 (0 .14 5)
2. 20 (0 .08 7) 2. 40 (0 .09 5)
1. 40 (0 .05 6)
MAX. MAX.
1. 00 (0 .03 9)
0.80 ( 0.032)
0. 40 (0 .21 3)
10. 94 ( 0.430)
10 .86 (0 .427 )
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 05/01