An AC generator rated at 90 kVA with a power factor of 0.85 lagging is


1.
capable of supplying
Your Answer: 76.5 kW of continuous power CORRECT
This question has been asked 1690 times with a success rate of 84 percent.
Comment/Reference: Floyd - Electronics Fundamentals pg 463
Members Home

Report problem
My Personal Details with question
Send your reference
My Control Panel
Store this
question
Take a Test
In an alternating current Star wired system, the phase voltage is 115 volts
2.
and the line voltage will be approximately
View Test Results
Your Answer: 200 volts CORRECT
Order Modules This question has been asked 1742 times with a success rate of 70 percent.
Comment/Reference: (No Comment/Reference Available)
Tutorial Support
Report problem
Study Notes with question
Send your reference
Logout Store this
question

An alternating current generator is operating at 50 kVA in a circuit with a


3.
power factor of 0.8. The real power is
Your Answer: 40kW CORRECT

http://club66pro.com/sequentialtest.php 6/13/2011
club66 professional - Sequential Test Page 2 of 3

This question has been asked 1645 times with a success rate of 84 percent.
Comment/Reference: (No Comment/Reference Available)

Report problem
with question
Send your reference
Store this
question

The two factors which govern the output frequency of an AC generator are
4.
the
Your Answer: the number of poles (in pairs) and the rotor RPM CORRECT
This question has been asked 1664 times with a success rate of 75 percent.
Comment/Reference: (No Comment/Reference Available)

Report problem
with question
Send your reference
Store this
question

5. A frequency wild generator


maintains a constant RPM but has a variable frequency
Your Answer:
INCORRECT
Correct Answer: has a variable frequency output
This question has been asked 1697 times with a success rate of 68 percent.
Comment/Reference: (No Comment/Reference Available)

Report problem
with question
Send your reference
Store this
question

6. On a 3-phase star wound generator, the line voltage is


Your Answer: more than the voltage from a single phase CORRECT
This question has been asked 1735 times with a success rate of 70 percent.
Comment/Reference: VL = 3VP

Report problem
with question
Send your reference
Store this
question

7. Output voltage of an A.C. generator is controlled by varying


Your Answer: speed of the generator INCORRECT
Correct Answer: field current
This question has been asked 1760 times with a success rate of 61 percent.
Comment/Reference: (No Comment/Reference Available)

Report problem
with question
Send your reference
Store this
question

If the inductive load of an unregulated A.C. generator is decreased, what


8.
happens to output voltage?
Your Answer: Remains constant INCORRECT
Correct Answer: Increases
This question has been asked 1707 times with a success rate of 58 percent.

http://club66pro.com/sequentialtest.php 6/13/2011
club66 professional - Sequential Test Page 3 of 3

Comment/Reference: (No Comment/Reference Available)

Report problem
with question
Send your reference
Store this
question

A 3 phase, 6 pole A.C. generator rotating at 4200 RPM, will produce output
9.
frequency of
Your Answer: 140 Hz INCORRECT
Correct Answer: 70 Hz
This question has been asked 1705 times with a success rate of 58 percent.
Comment/Reference: Consider only 1-phase. 2-poles per phase

Report problem
with question
Send your reference
Store this
question

If a delta connected A.C. system is operating at 115V phase, what is line


10.
voltage?
Your Answer: 230 V INCORRECT
Correct Answer: 115 V
This question has been asked 1706 times with a success rate of 62 percent.
Comment/Reference: (No Comment/Reference Available)

Report problem
with question
Send your reference
Store this
question

Continue with Next 10 Questions

Module Specific Links

AC Motors
All About Circuits Excellent electrical theory tutorials
Ibiblio Very good electrical circuits lessons
NEETS electrical US Navy Electrical basics CAA Acronyms
Online Conversions Convert just about anything, to anything and Terms
Play Hookey Great theory site for Modules 3, 4 and 5

Do you know of any good study websites for this module?


Tell us about them and we will post them here.

General Links

A+P Advisory Civil Aircraft


airtech Part-66 Ask a Subject
Mechanics Circular Inspection
books.com syllabus Specialist
Handbooks 43 Procedures

--- Privacy Policy | Terms and Conditions | Contact | Equal Opportunities and Diversity | Quality Policy
Copyright 2011 Total Training Support. All Rights Reserved.

http://club66pro.com/sequentialtest.php 6/13/2011

Das könnte Ihnen auch gefallen