Sie sind auf Seite 1von 2

Life-Saving

Life-Saving Technology
Technology Within
Within Reach
Reach

LIFELINE
LIFELINE AED
AED Semi-automatic
Semi-automatic Defibrillator
Defibrillator
Defibrillator
Defibtech
Defibtech
Defibtech hashas
has designed
designed
designed a arevolutionary
revolutionary This
a revolutionary This
This enables
enables
enables thethe
the device
device
device totoexceed
exceed
to exceed thethe
the
new semi-automatic
semi-automatic external
external
new semi-automatic external defibrillator, defibrillator,
defibrillator, American
American Heart
Heart Association
American Heart Association perfor-Association perfor-
perfor-
fromfrom the
the the ground
ground
ground up.up.up. mancemance
mance recommendations,
recommendations,
recommendations, giving
giving
giving thethe
the
user user
user confidence
confidence
confidence thethe
the correct
correct
correct therapy
therapy
therapy isis is
Technologically
Technologically
Technologically advanced
advanced
advanced enough
enough
enough tototo being being
being delivered.
delivered.
delivered.
include
include
include all
all mission
mission
all mission critical
critical
critical features
features
features nec-nec-
nec-
essary
essary to
to provide
provide the
the
essary to provide the most advanced most
most advanced
advanced The
The The Lifeline
Lifeline
Lifeline AED
AED AED defibrillator
defibrillator
defibrillator uses
uses uses
treatment
treatment for
for Sudden
Sudden
treatment for Sudden Cardiac Arrest. Cardiac
Cardiac Arrest.
Arrest. advanced biphasic
advanced biphasic technology
advanced biphasic technology
technology
Yet
Yet so
so simple
simple and
and unintimidating
unintimidating
Yet so simple and unintimidating to use to to use
use including
including
including thethe
the most
most most studied
studied
studied biphasic
biphasic
biphasic
that
that even
even non-medical
non-medical
that even non-medical personnel can personnel
personnel can
can shock
shock waveform
waveform
shock waveform and automatically and
and automatically
automati-
effectively
effectively
effectively save save
save lives.
lives.
lives. adjusts
cally
adjusts the the
adjusts the shock
shock shock delivery
delivery
delivery tototo thethe
the
persons
persons
persons individual
individual
individual needs.
needs.
needs.
TheThe
The Lifeline
Lifeline
Lifeline AED AED
AED was was
was developed
developed
developed bybyby
experienced
experienced
experienced multidisciplinary
multidisciplinary
multidisciplinary engineering
engineering For
engineering ForFor first
first response
first response
response professionals
professionals
professionals likelike
like
teams
teams and
and incorporates
incorporates
teams and incorporates state-of-the-art state-of-the-art
state-of-the-art police, fire and EMS, the
police, fire and EMS, the Lifeline AEDAED
police, fire and EMS, Lifeline
the LifelineAED
digital
digital signal
signal processing
processing
digital signal processing techniques and techniques
techniques and
and isisstandard
standard
is standard equipment.
equipment.
equipment. ForFor
For schools,
schools,
schools,
advanced
advanced ECG
ECG analysis
analysis
advanced ECG analysis algorithms. algorithms.
algorithms. offices,
offices, stores,
stores, malls,
malls,
offices, stores, malls, factories, and factories,
factories, andand
public
public places,
places, itsits becoming
becoming
public places, its becoming as vital as as as vital
vital as as
thethe
fire fire extinguisher.
extinguisher.
the fire extinguisher.

Defibtech,
Defibtech,
Defibtech, LLCLLC
LLC Guilford,
Guilford,
Guilford, CT CTCT06437
0643706437 1-203-453-4507
1-203-453-4507
1-203-453-4507
1-866-DEFIB-4-U
1-866-DEFIB-4U
1-866-DEFIB-4-U (1-866-333-4248)
(866-333-4248)
(1-866-333-4248) www.defibtech.com
www.defibtech.com
www.defibtech.com
Lifeline AED Semi-automatic Defibrillator
technical specifications*

Defibrillator Defibrillation/Monitoring Pads


TYPE VOICE PROMPTS MODEL SURFACE AREA
Semi-automatic external defibrillator Extensive voice prompts Adult DDP-100 103 cm2 (nominal, each pad)
guide user through operation Child/Infant DDP-200P 50 cm2 (nominal, each pad)
MODEL
of the unit and CPR
DDU-100A, DDU-100E TYPE PAD PLACEMENT
CPR PACING Pre-connected, single-use, Adult Anterior/Anterior
WAVEFORM
Metronome non-polarized, disposable, Child/Infant Anterior/Posterior
Biphasic Truncated Exponential
self-adhesive electrodes
(Impedance compensated) CONTROLS CABLE LENGTH (typical)
with cable and connector
Lighted On/Off button 48 in (122 cm)
ENERGY
Lighted Shock button
Adult: 150 Joules
Pediatric: 50 Joules INDICATORS
(Nominal into 50 Ohm load) check pads Event Documentation
do not touch patient
CHARGE TIME** INTERNAL EVENT RECORD REMOVABLE STORAGE
analyzing
DBP-2800: Less than 6 seconds Critical ECG segments and rescue (optional)
AED Status LED
DBP-1400: Less than 9 seconds event parameters are recorded Up to 12 hours of ECG and event
**Typical, with new battery at 25 C and can be downloaded to a data storage (no audio option) or
removable data card up to 2 hours of audio, ECG and
event storage (audio option) on a
Patient Analysis System PC-BASED EVENT REVIEW
removable data card. Actual length
ECG with event tag display,
of storage is dependent on card
PATIENT ANALYSIS SENSITIVITY/SPECIFICITY and audio playback when available
capacity
Automatically evaluates patient Meets AAMI-DF-39 specifications
impedance for proper pad contact. and AHA recommendations
Monitors signal quality and
analyzes patient ECG for shockable/ Environmental
non-shockable rhythms
TEMPERATURE SHOCK/DROP ABUSE
Operating: TOLERANCE
0 to 50C (32 to 122F) MIL-STD-810F 516.5 Procedure IV
Battery Pack Standby (with battery installed): (1 meter, any edge, corner,
0 to 50C (32 to 122F) or surface, in standby mode)
MODEL DBP-2800 MODEL DBP-1400 RELATIVE HUMIDITY SEALING/WATER
Operating / Standby: 5% 95% RESISTANCE
POWER 15V, 2800 mAh POWER 15V, 1400 mAh (non-condensing) IEC60529 class IP54;
Splash Proof, Dust Protected
CAPACITY 300 shocks or CAPACITY 125 shocks or ALTITUDE
(Battery Pack installed)
16 hours continuous operation** 8 hours continuous operation** -500 to 15,000 ft (-150 to 4500 m)
per MIL-STD-810F 500.4 Procedure II ESD
EN 61000-4-2:2009 (open air up to
STANDBY LIFE 7 years** STANDBY LIFE 5 years** VIBRATION
15kV or direct contact up to 8kV)
 round (MIL-STD-810F 514.5
G
TYPE LOW BATTERY INDICATORS Category 20) EMC (Emission)
Lithium/Manganese Dioxide Visible Helicopter (RTCA/DO-160D, EN 60601-1-2:2001 +A1:2006, limits
Disposable, recyclable, Audible Section 8.8.2, Cat R, Zone 2, EN 55011:1998 +A1:1999 +A2:2002
non-rechargeable Curve G) Group 1 Level B, method
**Typical, with new battery at 25 C Jet Aircraft (RTCA/DO-160D, EMC (Immunity)
Section 8, Cat H, Zone 2, EN 60601-2-4:2003, limits
Self Tests Curves B & R) EN 61000-4-3:2002
Level 3 (10V/m), method
AUTOMATIC USER-INITIATED
Automatic daily, weekly, monthly Unit and battery pack system test
and quarterly circuitry tests may also be initiated by the user Physical
BATTERY INSERTION STATUS INDICATION
SIZE WEIGHT (Approximate)
System integrity test Visual and audible indication
8.5 x 11.8 x 2.7 inches With DBP-1400: 4.2 lbs (1.9 kg)
on battery insertion of unit status
(22 x 30 x 7 cm) With DBP-2800: 4.4 lbs (2.0 kg)
PAD PRESENCE
Pads preconnected tested daily

*Specifications subject to change without notice


US

0197

Defibtech, LLC Guilford, CT 06437 1-203-453-4507 DAC-700-EN-BC rev A


1-866-DEFIB-4U (866-333-4248) www.defibtech.com ELECTRONIC DISTRIBUTION

Das könnte Ihnen auch gefallen