List of device numbers and acronyms

1 Master Element 59 Overvoltage Relay


2 Time Delay Starting or Closing Relay 60 Voltage or Current Balance Relay
3 Checking or Interlocking Relay 61 Density Switch or Sensor
4 Master Contactor 62 Time-Delay Stopping or Opening Re
5 Stopping Device 63 Pressure Switch
6 Starting Circuit Breaker 64 Ground Detector Relay
7 Rate of Change Relay 65 Governor
8 Control Power Disconnecting Device 66 Notching or Jogging Device
9 Reversing Device 67 AC Directional Overcurrent Relay
10 Unit Sequence Switch 68 Blocking or "Out-of-Step" Relay
11 Multi-function Device 69 Permissive Control Device
12 Overspeed Device 70 Rheostat
13 Synchronous-speed Device 71 Liquid Level Switch
14 Underspeed Device 72 DC Circuit Breaker
15 Speed or Frequency, Matching Device 73 Load-Resistor Contactor
16 Data Communications Device 74 Alarm Relay
17 Shunting or Discharge Switch 75 Position Changing Mechanism
18 Accelerating or Decelerating Device 76 DC Overcurrent Relay
19 Starting to Running Transition Contactor 77 Telemetering Device
20 Electrically Operated Valve 78 Phase-Angle Measuring Relay
21 Distance Relay 79 AC Reclosing Relay
22 Equalizer Circuit Breaker 80 Flow Switch
23 Temperature Control Device 81 Frequency Relay
24 Volts Per Hertz Relay 82 DC Reclosing Relay
25 Synchronizing or Synchronism-Check 83 Automatic Selective Control or Trans
Device Relay
26 Apparatus Thermal Device 84 Operating Mechanism
27 Undervoltage Relay 85 Communications,Carrier or Pilot-Wir
28 Flame detector 86 Lockout Relay
29 Isolating Contactor or Switch 87 Differential Protective Relay
30 Annunciator Relay 88 Auxiliary Motor or Motor Generator
31 Separate Excitation Device 89 Line Switch
32 Directional Power Relay 90 Regulating Device
33 Position Switch 91 Voltage Directional Relay
34 Master Sequence Device 92 Voltage and Power Directional Relay
35 Brush-Operating or Slip-Ring Short- 93 Field Changing Contactor
Circuiting Device 94 Tripping or Trip-Free Relay
36 Polarity or Polarizing Voltage Devices 95 For specific applications where other
37 Undercurrent or Underpower Relay numbers are not suitable
38 Bearing Protective Device 96 For specific applications where other
39 Mechanical Condition Monitor numbers are not suitable
40 Field (over/under excitation) Relay 97 For specific applications where other
41 Field Circuit Breaker numbers are not suitable
42 Running Circuit Breaker 98 For specific applications where other
43 Manual Transfer or Selector Device numbers are not suitable
44 Unit Sequence Starting Relay 99 For specific applications where other
45 Abnormal Atmospheric Condition numbers are not suitable
AFD Arc Flash Detector
Monitor
46 Reverse-phase or Phase-Balance CLK Clock or Timing Source
Current Relay DDR Dynamic Disturbance Recorder
47 Phase-Sequence or Phase-Balance DFR Digital Fault Recorder
Voltage Relay ENV Environmental Data
48 Incomplete Sequence Relay HIZ High Impedance Fault Detector
49 Machine or Transformer, Thermal Relay HMI Human Machine Interface
50 Instantaneous Overcurrent Relay HST Historian
51 AC Inverse Time Overcurrent Relay LGC Scheme Logic
52 AC Circuit Breaker MET Substation Metering
53 Exciter or DC Generator Relay PDC Phasor Data Concentrator
54 Turning Gear Engaging Device PMU Phasor Measurement Unit
55 Power Factor Relay PQM Power Quality Monitor
56 Field Application Relay RIO Remote Input/Output Device
57 Short-Circuiting or Grounding Device RTU Remote Terminal Unit/Data Conce
58 Rectification Failure Relay SER Sequence of Events Recorder
TCM Trip Circuit Monitor
SOTF Switch On To Fault