which one alarm happend ?

1. ALM-26522 RF Unit RX Channel RTWP/RSSI Unbalanced


Possible Causes
a.The main RX channel or diversity RX channel of the RF unit is faulty.
b.The setting of attenuation on the RX channel of the RF unit is incorrect.
c.External interferences exist on the main or diversity antenna of the RF unit.
d.The feeder connected to the RF unit is faulty, which results in a high passive intermodulation power of the main antenna.

2. ALM-26521 RF Unit RX Channel RTWP/RSSI Too Low


Possible Causes
a.The setting of attenuation of the RF unit is incorrect.
b.The TMA is faulty.
c.The feeder installation is improper. For example, the feeder connector is loose, soaked or damaged, or the feeder is deformed.
d.The RF unit is faulty.

3. ALM-26239 RX Channel RTWP/RSSI Unbalanced Between RF Units


Possible Causes
a.The main RX channel or diversity RX channel of the RF unit is faulty.
b.The attenuation setting of the RX channel of the RF unit is incorrect.
c.External interferences exist on the antenna connected to the RF unit.
d.The feeder connected to the RF unit is faulty, which results in a high passive intermodulation power of the main antenna.