Beruflich Dokumente
Kultur Dokumente
Using as much natural light in buildings as Light is not only an amount of energy,
possible has many advantages over using it also provides us with the eans to reveal spaces
articial lights, if its penetration is appropriately and volumes and interact with our environment.
controlled.
4
KS1000
Hybrid
Thermalight
6
KS1000
Polycarb
Rooight
16
KS1000
RW/GRP
24
KS1000
Wall-Lite
30
Tubular
skylights
40
Roof
Insulated
Upstands
42
Energy
Efcient
Buildings
44
3
of roof area (prismatic daylighting) reduces lighting
energy demand by during daylight hours.
Daylight savings
People love natural light. Subconsciously, unknowingly, we seek out sunlit places and enjoy spend-
ing time in natural light. Beyond this desire, however, are some tangible benefits to adding natural
TABLE 1
Simple Payback Period, years, by Climate Zone and Building Type
TABLE 2
Energy Cost Savings /yr/m2, by Climate Zone, City and Building Type*
Climate Zone City Ofce School Warehouse Retail
MDS Athens, GR 1.91 2.38 2.55 5.09
MDN Split, CR 2.07 2.55 2.55 4.45
ALS Innsbruck, AT 1.82 2.07 2.07 3.51
PAN Debrecen, HU 1.75 1.91 1.85 3.33
CON Warsaw, PL 1.60 1.70 1.70 3.03
ATN Bremen, DE 1.44 1.55 1.48 2.69
MDS - Mediterranean South, MDN - Mediterranean North, ALS - Alpine South, PAN - Pannonian, CON - Continental, ATN - Atlantic North
* Calculated taking into consideration average energy cost of 1 kWh =0,16 for all these cities/countries
(Source: Eurostat)
Bright Benets
The primary reason for including wall&rooights Light panels save energy
is to provide a bright, naturally lit interior and and reduce carbon emissions.
reduce the requirement for articial lighting. Can replace electric lighting 70 to 80%
Daylight has many advantages over articial of the daylight hours while producing
light - not least the fact that it is a completely much less heat than electric lighting.
free, unlimited natural resource. Whilst articial Improve employee morale
light is essential, its provision uses a lot of energy, Reduce absenteeism
so reducing the requirement will dramatically cut Reduce errors
energy use, and the CO2 emissions which result Improve product quality
from this. Increase productivity
Increase sales in retail stores up to 40%
Introduction
Every workplace should have suitable and sufcient
lighting, which should, so far as is reasonably prac- KS1000 RW/HTL offers excellent interior
tical, be by natural light. The most effective method levels of natural light without compromising
of providing even, consistent daylight, particularly the performance of the building. This can help
in large buildings, is through rooights, which are to lower both energy bills and CO2 emissions.
up to three times more effective than windows
around the perimeter of the building.
Lower your energy bills up to 55 % with Kingspan
Diffused lighting should be used to provide Hybrid Rooights.
even light distribution and avoid glare.
42
1000mm
Panel thickness 16 25 32
2
Weight (kg/m ) 5,0 5,9 6,6
The shape of the GRP top layer is same Kingspan Technical Department.
Installation
Site assembly instructions are available
from Kingspan.
Construction details
KS 1000 RW/HTL
PVC sealing tape
(factory applied)
03
P
at 300mm
19
P 243
K
21
P
08
P
at 300mm
KS1000 RW
Roof purlin
Side Laps
KS1000 RW/HTL to KS1000 RW panel
29
27
P
P
at 300mm
KS 1000 RW/HTL
KS1000 RW
19
P
21
P
242
K
08
P
Roof purlin
at 300mm
A
B
00
150 - 3
50
27
P 04
30 P
at 300mm
rivet "bulbtite"
callote
type between
crowns
"overlay"
of distance profile
KS1000 RW
KS1000 RW/HTL
distance profile
support
21
P
B
08
P fasteners
(distance profile to purlin)
additional support
if purlin width is < 100 mm
A
Section A-A
Section B-B
Construction details
A
B 150 - 3
0 0 50 KS1000 RW/HTL
30
"overlay"
of distance profile
03
P 08
at 300mm P
distance profile
support
fasteners (distance
profile to purlin)
21
P
additional support
if purlin width is < 100 mm
KS1000 RW
04
P
B
Section A-A
Section B-B
A
callote
04
B
P
30 0 30
21 150 -
P
30
27
P
"overlay"
of distance profile
rivet "bulbtite" fasteners
type between crowns (distance profile to purlin)
distance profile
21 support
P
B
additional support
if purlin width is < 100 mm
08
P distance profile
support
A
Section A-A
side
flashing
Section B-B
side
flashing
Construction details
Intermediate Detail
RW/HTL
A
callote
04
P
KS1000 RW/HTL
"overlay"
of distance profile
08
P
distance profile
support
fasteners
(distance profile to purlin)
A
Section A-A
LIGHT TRANSMISSION UP TO 63 %
Introduction
Sustainability is the latest buzzword in not just By allowing more natural light in to a building,
the construction industry, but in the wider environ- the need for articial lighting is reduced.
ment too. Sustainability however is far from just
The benets of using rooights go further than
being a fad it is a way of living and constructing,
just reducing our energy consumption; research
to help preserve the environment in which we live.
has shown that increased levels of daylight can
There are indeed many ways of acting sustainably,
aid health, learning and also increase productivity.
but one of the easiest and cost efcient ways is to
reduce the energy that we use. The Kingspan Polycarb Rooight allows natural
light to penetrate in to the building, therefore
One way of reducing the energy we use reducing the need for articial lighting.
is to reduce our reliance on artificial lighting The rooight system, which is designed for use
to light our buildings. with the KS1000 RW system, is made from
polycarbonate, a lightweight, high performance,
How though, do you reduce the amount
durable plastic. It has superior UV resistance and
of articial light yet maintain a workable level
will not discolour over time coupled with a U-value
of lighting? The answer is to incorporate rooight
of 1.64W/mK.
systems into roof constructions.
42
35mm
Dim B
Dim A
End Lap Cut Back
Standard
Cut bac
k
150mm
Delivery Safety
Road Freight The contractor is to determine and use a safe system
of working throughout the installation and construction
All deliveries (unless indicated otherwise) are
period which complies with the HSA or HSE and CDM
by road transport to project site. Unloading
requirements. Crawling boards should be used when
is the responsibility of the customer.
xing rooights.
Sea Freight
Construction details
Site applied
4 No. main fixings with magnetic spacer
storm washer in each
crown location, per
rooflight, per purlin
KS1000 RW insulated roof panel 30 min
4 No. main fixings with 4 No. main fixings with
storm washers storm washers
Site applied
spacer
Kingspan Polycarb Rooflight to Panel Side Lap Panel to Kingspan Polycarb Rooflight Side Lap
Side laps stitched at max 300mm c/cs with Side laps stitched at max 300mm c/cs with
Mega-stitcher screws (typ 6.3mm dia x End lap stitchers only Mega-stitcher screws (typ 6.3mm dia x
25mm long) with 19mm dia washers inserted where rooflight end 25mm long) with 19mm dia washers
laps over KS1000 RW panel
6 x 5mm butyl rubber sealant applied 6 x 5mm butyl rubber sealant applied
in continuous unbroken length at side in continuous unbroken length at side
PVC painted steel lap to weather side of stitching screw lap to weather side of stitching screw
strip (factory fitted)
30 min
30 min 4 No. main fixings with storm
Site applied magnetic spacer washer in each crown location,
per rooflight, per purlin
Construction details
Kingspan Polycarb
Rooflight
Intermediate Detail
Intermediate Purlin Fasteners
30 min
KS1000 RW/GRP
42
lengts from 1.8 to 6.5 metres. with National Building Regulations and Norms.
approximately 70%
Length 10 mm KS1000 RW/GRP
and are opaque
Width 3 mm
side to weather side (to minimise palette of working throughout the installation and construction
period which complies with the HSA or HSE and CDM
height).The top, bottom, sides and ends
requirements. Crawling boards should be used when
are protected with foam and timber packing
xing rooights.
and the entire palette is wraped in plastic.
Delivery
Installation
Site assembly instructions are available
from Kingspan.
Kingspan will arrange training of the site tters
and supervisors if requested.
Side Laps
RW/GRP to KS1000 RW panel
Module Module
RW/GRP RW
Side Laps
KS1000 RW panel to RW/GRP
Module Module
Lap-Lox/Tramslap
stiching screw Self-tapping or self-drilling screw
Butyl sealing tape or PVC with thread under head and sealing washer 29
(at 300-500 mm) - P27 sealing tape (site applied)
D
L
RW RW/GRP
d
04p 04
P P
A
P 50
50
RW
RW/GRP
A
a
a
Section A-A
Section A-A
Note:
a - according to structural/static requirements
P - cut back dimension 250 mm
B
P 50
50
RW/GRP
RW
B
a
a
PE profiled
or permanently sealing filler
34 18 17
P elastic sealant P P (factory applied)
Note:
a - according to structural/static requirements
P - cut back dimension 250 mm
Section B-B
Introduction
The Kingspan Wall-Lite is a translucent wall and Kingspans range of complete wall and
panel that allows natural daylight into buildings, faade systems including the ThermabrickTM,
whilst maintaining thermal efciency and aesthetic Thermastone and Thermatile systems.
appearance.
The Kingspan Wall-Lite is UV resistant,
lightweight and offers a U-value of 1.26 W/m2K
The Kingspan Wall-Lite offers excellent interior
levels of natural light without compromising offering designers and installers choice of freedom
42
TT
TT
(S\TPUP\TZWHJLYZ[VZ\P[HKQHJLU[PUZ\SH[LKWHULS[OPJRULZZ
approximately 55%
KS1000 WL
Product Tolerances and are opaque
Cut to Length:
Panel Thickness:
Thickness d 50 mm 2 mm
Thickness d 100 mm +3 mm 3 mm
Panel bow (1 + 2) / 2 10 mm
on wooden pallets. The top, bottom, sides panels installed as a single band highlight is 6 m.
Maximum spacing for WL panels installed
and ends are protected with polystyrene
in series is 3 m.
spacers and the whole package is wrapped
with foil. BUILDING REGULATIONS
KS1000 WL panels meet the requirements
Delivery of national building standards
Road Freight and regulations.
All deliveries (unless indicated otherwise) are
by road transport to project site. Unloading
is the responsibility of the customer.
Installation
Installation instructions are available in Kingspan
Technical Department. We also provide, on request,
trainings for contractors.
Colour Range
Kingspan Wall-Lite is available in a range of colours to give designers choice and freedom.
Cl
Clear O
Opall Bl
Blue G
Green
Purple
P l R
Red
d O
Orange Y
Yellow
ll
*The only Standard color is Clear. If you need other colors, please contact Kingspan rst.
Spacing proles
TT
TT
(S\TPUP\TZWHJLYZ[VZ\P[HKQHJLU[PUZ\SH[LKWHULS[OPJRULZZ
40,5
40,5
60,5
60,5
20,5
30,5
30,5
50 80
40 80 38 mm 40,5 mm 80 mm
Joint Detail
38 mm 30,5 mm 70 mm
female joint male joint
38 mm 20,5 mm 60 mm
KS1000 AWP 80
a) AWP/WL (profile A) b) WL/WL (profile B) a) WL/AWP (profile A)
KS1000 AWP 70
a) AWP/WL (profile A) b) WL/WL (profile B) a) WL/AWP (profile A)
KS1000 AWP 60
a) AWP/WL (profile A) b) WL/WL (profile B) a) WL/AWP (profile A)
Construction details
Steel support
Steel support
Snap on cover flashing or 4mm dia. butyl rubber sealant site applied
optional recessed cover flashing
6mm dia. run of gun grade sealant*
Wall Abutment
Abutment flashing Air seal - 6mm dia. bead of gun grade sealant*
Note: A vertically laid option is available from Kingspan enviro care Technical Services on 0800 587 0090.
*Always ensure only polycarbonate compatible gun grade sealant is applied to Kingspan Wall-Lite.
Construction details
Cleader angle
*Always ensure only polycarbonate compatible gun grade sealant is applied to Kingspan Wall-Lite.
LIGHT TRANSMISSION UP TO 98 %
SUNPIPE
SP300 300 mm 14 m2
a a
d
D
21
P
crystalline head
Al sheet with layer of pure silver
78 98
window 78 118
frame sizes: 78 140
78 160
Dome rooights
100x100
Production sizes
100x200
(size of hole in the
120x120
roof):
150x150
Fire Dampers
Reduce use
2 Maximise the use 3 Use fossil fuels
Use renewables of renewable energy in the cleanest
sources possible way
Be efcient with the remaining resources
STEP The implementation of Energy Performance With closed-cell, high performance insulation
One of the key aspects for the success of integrating sources of renewable energy into
construction programmes is the ease with which they can be incorporated into building design.
Kingspan has a number of solutions which meet this criterion, starting with the building envelope itself.
Renewable Energy
STEP
TWO
Kingspan designs, manufactures and supplies approximately Kingspan EnergiPanel is an innovative insulated solar
20 million m2 of insulated roof, wall and faade panels per air heating system designed for roof and wall applica-
annum and works in close conjunction with leading building tions as a supplement to the main heating system.
investors, owners, developers, designers and construction Proled hollows beneath the crowns allow air move-
teams for the property market. ment up through the panel and the air is warmed by
This capability has enabled us to introduce a range of fully the simple process of using the outer steel skin as
integrated solar photovoltaic solutions for roofs, walls and a solar energy absorber. The darker the external colour
faades from a single, trusted provider, eliminating multi- of the panel the greater the solar absorption.
sourcing, installation and building envelope integration risks. Because it is a single component system, Kingspan
Photovoltaic (PV) systems generate clean, ination proof EnergiPanel allows fast track construction, so the over-
electricity, reduce energy costs and can generate electricity all carbon footprint associated with the installation is
to be fed into the national grid or used within the building minimised. The system integrates seamlessly with other
itself. Even if the sky is overcast, PV is proven to produce panel systems from the Kingspan range and is available
electricity. in a range of colours.
Every kW produced has zero-carbon emissions, The Kingspan EnergiPanel combines Kingspans
which signicantly reduces the carbon footprint. It limits existing state of the art insulated panel techno-
dependency on fossil or nuclear fuels and facilitates meeting logy with a tested and proven solar air heating
corporate social responsibility needs. Such an investment capability.
could increase the saleable / rentable value of the building The EnergiPanel Solar Air Heating System has
and would enhance the buildings energy ratings. the exibility of being either integrated with the existing
HVAC system or utilised in a standalone heating capac-
ity. It is available with the Kingspan Total Guarantee
covering both the thermal and structural performance.
the shortfall in energy supply, this should be done as cleanly and as sparingly as possible.
The aim of safeguarding the natural resources has led Kingspan to develop a range of solutions that
instead of consuming fossil-depleting energy, capitalize on the most natural of resources sunlight.
Reduce demand
The simplest way to save the energy is just to turn off the Harvesting daylight
lights. We could reduce our demand for electricity by thou-
This vision has compelled Kingspan to introduce a range of sands of megawatts just by opening up our buildings to
products that bring the natural light into the buildings, thus daylight and the Kingspan Wall-Lite, a translucent wall
reducing the need for articial, energy-consuming lighting. panel, does exactly that.
Allows for efcient light diffusion, which helps avoid buildings, and integrates fully with Kingspan Architec-
hot spots and disperse light evenly in sections between tural Wall panels, Kingspan OptimoTM, and Kingspans
The economy of using the Kingspan Polycarb Rooights is Fully recyclable, the Kingspan Wall-Lite helps lower
amplied by savings on lifecycle costs once installed, the both energy operating costs and CO2 emissions, whilst
rooights do not require spare parts or vigilant maintenance. allowing the buildings occupants to enjoy and benet
The Kingspan Polycarb Rooight is 100% recyclable and has from high levels of daylight.
The research found that demolition results Kingspan Insulated Panels has adopted BREs
in the insulation generally going to landll whether Environmental Proles Assessment Methodology
it be PUR, PIR, rock bre or glass bre. In the light to quantify the environmental impact of its panels.
of this conclusion, Kingspan Insulated Panels continues Kingspan Insulated Panels is delighted that its
to actively explore ways of stimulating the end-of-life Architectural Wall Panel and Trapezoidal Roof and
management of its panels, including an on-going Wall product range have all been reassessed under
reduction in the environmental footprint of new the latest Green Guide to Specication and achieved
products to reduce the future legacy. A+ ratings.
Roof Specication*
High Performing Specications Poor Performing Specications
A+ A B C D E
Best Worst
Performing Performing
Roof Kingspan KS1000 RW Roof Specications
Specications 0.42 Ecopoints
Wall Specication
High Performing Specications Poor Performing Specications
A+ A B C D E
Best Worst
Performing Performing
Kingspan KS1000 RW
Roof Roof Specications
0.47 Ecopoints
Specications
KS600/900/1000 AWP
0.53 Ecopoints
Low Pitched Roof: KS1000 RW Panel with External Wall: KS1000 RW Panel with insulation core manu-
insulation core manufactured at Holywell. Supported on factured at Holywell, vertically laid. Supported on cold rolled steel rails.
cold rolled steel purlins and structural sections. Steel Steel facings; generic organic coatings. Insulation 70mm core thickness.
facings; generic organic coatings. Insulation 120mm KS600/900/1000 AWP Panel with insulation core manufactured
core thickness. at Holywell, horizontally laid. Supported on cold rolled steel rails and struc-
tural frame. Steel facings; generic organic coatings. Insulation 80mm core
thickness.
Roof Systems
IPN Core
KS1000 RW KS1000 TOP-DEK KS1000 RT KS1000 X-DEK
Trapezoidal Flat RoofTile Flat
02-2012