90
Passive design
Design for climate
Thermal simulation software can model with great Gaining body heat
accuracy the amount of heating or cooling energy
required to achieve physiological comfort; it is unable When the heat produced by our bodies is insufficient to
to model highly variable human perceptions of comfort. maintain body temperature, we shiver. This generates
Sound building envelope design based on modelling body heat and has a short-term physiological effect
delivers an environment that addresses all the physical but also triggers our deepest psychological discomfort
factors necessary for comfort (except humidity) but cant warning mechanisms. Our first response is generally
always meet our psychological comfort needs. to insulate ourselves by putting on more clothes and
sheltering from wind and draughts. These actions are
Important triggers for psychological discomfort are effective because we generate most of the heat we
radiation, air movement and conduction. Although they require from within, and reducing heat loss makes body
are less effective physiologically, they trigger innate heat more effective. Our minds quickly decide whether
self-preservation responses that override our ability the adjustment is adequate for thermal comfort.
to perceive physical comfort. Until they are met, we
dont feel thermally comfortable and our behaviour A secondary source of heat gain is radiation. As with
can render the best of design solutions ineffective. cooling, radiation is very important to our perception of
Acclimatisation is a critical component of psychological comfort. For example, we can feel cold in a room that
comfort. is a comfortable 22C if there is a cold window nearby;
conversely, we can feel warm at 0C if we are well
Psychological thermal discomfort can make us set insulated with warm clothing and standing in the sun.
the thermostat on heating or cooling systems well
beyond levels required for comfort. For every 1C The final source of heat gain is conduction. Simply
change in thermostat setting, it is estimated that our holding someones hand can create psychological
heating or cooling bill rises by around 10%. In other thermal comfort though a small amount of conduction.
words, failure to address psychological comfort can We conduct to cool floors and from heated floors.
increase heating and cooling energy use by up to 50% Heated floors also provide radiant heat and raise air
(Australian Greenhouse Office 2005). temperatures through conduction and convection.
91
Passive design
Design for climate
The eight climate zones used in Your Home are defined 1 Hot humid summer, warm winter
by the Building Code of Australia (BCA). Each climate Warm humid summer, mild winter
2
zone has distinctly different design and construction
requirements. Within each main zone are many regional 3 Hot dry summer, warm winter
sub-zones determined by local geographic features Hot dry summer, cool winter
4
including wind patterns and height above sea level.
NatHERS identifies 69 of these sub-zones, which the 5 Warm temperate
BCA addresses and which can be called up by postcode. Mild temperate
6
Climate change is likely to alter the characteristics 7 Cool temperate
of each zone during the life span of homes currently
being built or renovated. 8 Alpine
DARWIN
Weipa
Katherine
Wyndham
Cooktown
Cairns
Broome
Tennant Creek Townsville
South
Latitude 20 Mount Isa
Mackay
Launceston
HOBART
92
Passive design
Design for climate
Zone 1: Hot humid summer, Prioritise design for night-time sleeping comfort.
Consider sleep-out spaces.
warmwinter
Provide shaded outdoor living areas.
Main characteristics Locate pools and spas on the northern side of the
High humidity with a building where they are shaded in the hot humid
degree of dry season season and warmed during the dry season.
Install ceiling fans in all rooms.
Moderate to high
temperatures year round Windows and shading
Low to moderate seasonal Shade all windows and walls, including south facing,
temperature variation with extended eaves where possible or vertical
shading where not.
Minimal diurnal (daynight) temperature range Use low solar heat gain coefficient (SHGC) glazing
(see Glazing).
Key design objectives
Use multiple layers of reflective roof and ceiling
Homes in these climates use substantially more energy insulation to create a one-way valve effect.
to achieve thermal comfort than homes with the same Insulate internal wall surfaces well from any external
NatHERS star rating in more benign climates. It is thermal mass (e.g. brick veneer).
therefore imperative to use design strategies that reduce
cooling energy use to achieve similar carbon reductions. Exclude solar radiation from roof, windows and walls
For example, a 6 star house in Darwin uses more than (see Shading).
double the energy of a 1 star house in Brisbane, and a Consider shading the whole building with a fly roof
9 star house in Wyndham (WA Kimberley region) uses (see Passive cooling).
about the same as the Brisbane 1 star house.
Insulation
One of three distinctly different design approaches Refer to Insulation for appropriate insulation levels in
should be chosen at the outset of the design process. each climate zone.
Each produces a very different solution that is often
difficult to change in the future. Avoid bulk insulation to ceilings and walls except in
conditioned spaces.
Free running: These buildings should not be
conditioned (mechanically heated or cooled). Ventilate roof spaces well with fans or whirlybirds
Abundant air movement from fans, whirlybird and design for condensation removal (see Passive
ventilators, stack ventilation and cross-ventilation is cooling).
essential. Insulate elevated floors with reflective, closed-cell
Conditioned: These buildings must be well insulated bulk insulation to resist upward heat flow and
and able to be made airtight while conditioning is condensation.
running. Both inward and outward condensation Line open ventilated spaces with reflective foil
issues should be addressed. insulation.
Hybrid design: These buildings include air In conditioned buildings
conditioned, insulated core rooms in the centre
of the house (e.g. a TV room) for peak discomfort Avoid overuse of glazing.
periods, surrounded by free running spaces. Use the highest energy rated conditioning appliances
and install smart control systems and a variable
Unconditioned sleeping comfort is a critical design output speed compressor to maximise efficiency
consideration in both conditioned and hybrid design (see Heating and cooling).
approaches.
Condition only critical rooms in preference to the
Key responses entire house.
Design air conditioned spaces to be sealed off,
Design considerations
preventing loss of cooling when running.
Orientate the building to take full advantage of Design to accommodate both inward and outward
cooling breezes, and position landscaping and condensation (wherever humid warm air first meets
outbuildings to funnel breezes over, under and a cooler surface).
through the building (see Orientation and Passive
cooling).
93
Passive design
Design for climate
Use low U-value glazing to avoid ambient or Zone 2: Warm humid summer,
conducted heat gain or cooling loss (see Glazing).
mildwinter
Provide ceiling fans in conditioned spaces
they provide effective cooling when conditioning Main characteristics
lowers humidity.
High humidity with a
Use internal thermal mass walls surrounding definite dry season
conditioned central cores for radiant cooling
of adjoining unconditioned sleeping spaces. Hot to very hot summers
with mild winters
In free running buildings
Distinct summer/winter
Encourage natural air flow with large, high level
seasons
openings.
Use only 100% openable windows such as louvre Moderate to low diurnal (daynight) temperature range,
or casement. which can vary significantly between regions (e.g. inland
Locate sleeping spaces in lower levels. to coastal)
Use low or no thermal mass finishes in sleeping Key design objectives
spaces to prevent radiant heat at bed-time.
Maximise external wall areas (plans with one room Eliminate auxiliary heating and substantially reduce
depth are ideal) to encourage cross-ventilation. cooling with appropriate passive design.
Elevate building to permit air flow beneath floors. Key responses
Construction systems Design considerations
Use lightweight (low mass) construction Always site for exposure to cooling breezes and
(see Thermal mass). design for cross-ventilation.
Use light coloured reflective materials externally. Use thinner plans and design openings to encourage
Design and build for cyclonic conditions. movement of breezes through and within the
building (see Passive cooling).
Always design for night-time sleeping comfort.
Provide screened and shaded outdoor living areas.
Insulation
In areas where no winter heating is required, use
multiple layers of reflective foil in ceiling/roof to
create a one-way valve effect.
Insulate internal wall surfaces from any external
thermal mass (e.g. brick veneer).
94
Passive design
Design for climate
Refer to Insulation for recommended minimum Zone 3: Hot dry summer, warmwinter
insulation levels.
Use highly breathable reflective vapour barriers in Main characteristics
walls and add bulk insulation to rooms that are air Distinct wet and dry
conditioned. seasons
Use roof spaces to provide heat loss/gain buffer
zones by ventilating them in summer and sealing Low rainfall and low to
them in winter with fans or smart ventilators moderate humidity
(see Passive cooling). No extreme cold but can
Line open ventilated spaces with reflective foil be cool in winter
insulation and design to remove condensation.
Avoid installing bulk insulation in ceilings and Hot to very hot summers
walls unless winter heating is used. common
95
Passive design
Design for climate
Use low SHGC glazing in regions with hot summers Zone 4: Hot dry summer, cool winter
and mild winters.
Shade all east and west-facing glass in summer Main characteristics
(see Shading). Distinct seasons with low
Shade south-facing glass north of the tropic of humidity all year round
Capricorn.
High diurnal (daynight)
Insulation temperature range
Use bulk and reflective insulation in ceilings, and bulk Low rainfall
or reflective insulation in walls.
Provide external insulation to all thermal mass. Very hot summers
common with hot, dry
Insulate under concrete slabs if using in-slab heating. winds
Insulate elevated floors (lightweight or concrete).
Refer to Insulation for recommended minimum Cool winters with cold dry winds
insulation levels.
Key design objectives
Ensure all spaces are effectively air sealed.
Well-designed passive solar heating and cooling are
Heating and cooling equally important. Application of sound passive design
principles can achieve cost effective 8 star or better
Use evaporative cooling and passive solar heating in
thermal performance in this climate zone. High thermal
living areas.
mass solutions are particularly effective.
Provide ceiling fans in all living and sleeping spaces.
In more extreme regions consider active solar Active solar heating and cooling systems are well suited
heating and reverse night cooling connected to to sunny winters and clear summer night skies, and will
in-slab hydronic systems. also provide flexible thermal comfort solutions for
future climate change.
Check typical heating and cooling requirements
in the local area to determine appropriate
Key responses
passive heating levels (consult your local thermal
performance expert). Design considerations
96
Passive design
Design for climate
97
Passive design
Design for climate
Insulation
Use bulk and reflective insulation in ceilings, and bulk
or reflective insulation in walls.
Insulate under concrete slabs if using in-slab heating.
Provide external insulation to all thermal mass.
Insulate elevated floors (concrete and lightweight)
Refer to Insulation for recommended optimal
insulation levels.
Ensure all spaces are effectively air sealed.
98
Passive design
Design for climate
99
Passive design
Design for climate
Key responses
Design considerations
Apply best practice passive solar design principles
where access to sunlight permits. Use high glass to
mass ratios.
Consider climate change when choosing type,
location and quantity of thermal mass.
Maximise the use of north-facing walls and passively
shaded glazing.
Locate living areas on the north, bedrooms and
service areas on the south.
Minimise external wall areas, especially east and west.
Use cross-ventilation and night-time cooling in
summer.
Avoid high ceilings and provide airlocks between
lower and upper floors.
100
Passive design
Design for climate
Design for controllable (zoned) convective air Use closed cell reflective insulation in preference
movement throughout the house to distribute to compressed bulk insulation where supplier
heat while minimising draughts and temperature recommends an anti-condensation layer under
stratification. roof material.
Site new homes for solar access, exposure to cooling Insulate all elevated floors (concrete and lightweight).
breezes and protection from cold winds. Insulate slab edges.
Where passive solar access is unavailable, minimise Insulate under concrete slabs if using in-slab heating.
all glass areas and limit thermal mass except where
Provide airlocks to entries.
exposed to heating sources.
Effectively air seal all spaces (see Sealing your home).
Design furniture layouts to minimise exposure to
convection draughts. Refer to Insulation for recommended optimal
insulation levels.
Ventilate roof spaces in summer and seal them
in winter (use automated fans or closable roof Heating and cooling
ventilators).
Even 10 star homes in the more extreme regions of
Install carbon efficient auxiliary heating.
these climates might require some auxiliary heating
Use renewable energy sources. for psychological comfort.
(see also Passive solar heating; Passive cooling; Thermal Lower rated homes will require heating.
mass; Orientation; Renewable energy) High level passive or active solar heating is highly
desirable where available.
Windows and shading
Well-designed active solar energy systems with
Avoid overuse of glazing. substantial heat storage capacity or an efficient heat
Careful sizing and orientation of windows is pump (ground, water or air source) are the most
essential. carbon efficient (see Heating and cooling).
Use high SHGC, low U-value double glazing. Wood heating, although it is carbon neutral, has
negative health and biodiversity impacts and should
Specify insulating or thermally improved frames.
be avoided in built-up areas.
Design and detail for preventing window
Well-positioned, adequately heated thermal mass
condensation.
will provide sufficient thermal comfort in bedrooms
Passive solar shading to northerly windows is (sleeping comfort is less of an issue in cool or cold
essential. climates).
Minimise and shade all east and west-facing glass Cooling is unnecessary with good cross or closable
in summer (see Shading). ventilation and ceiling fans in living and sleeping
Consider using adjustable shading to some spaces.
west-facing glass areas to boost afternoon solar
heat gains in winter and allow variable solar access Construction systems
in spring and autumn. Earth coupled slabs are beneficial except where
3m earth temperatures are below 16C in winter
Insulation
(e.g. Tasmania). Insulate under the slab or use
Use bulk insulation in walls, ceilings and exposed insulated, lightweight floors in these regions.
floors. Use low thermal mass walls on sites with no
Use heavy drapes with sealed pelmets to insulate solar access.
glass in winter. Use lightweight wall construction where diurnal
For walls use bulk insulation with highly breathable temperature ranges are low (e.g. Hobart) and
sarking or multiple layers of reflective foil insulation, increase thermal mass and solar exposed glass
with detailed design to ensure condensation as they increase above 6C.
discharge. Choose light coloured roof materials.
Insulate all thermal mass externally
(including rammed earth and mud brick).
Use high levels of bulk insulation in ceilings and
line underside of roofing material with down-facing
reflective foil.
101
Passive design
Design for climate
102
Passive design
Design for climate