High Voltage Instrument Transformers

Product listing

The following HV Instrument Transformers are used for metering, Primary insulators with cemented flanges may be offered in either ANSI
relaying or control on high voltage circuits. These products are 70 gray porcelain or silicone rubber polymer design. Metallic housings
intended for pedestal mounting in substations to allow safety have corrosion resistant painted polyester steel tanks and domes, or
clearances. All transformers are hermetically sealed and equipped with galvanized steel tanks with aluminum domes. An oil level gauge and
NEMA 4 hole primary terminals and NEMA 2 hole ground pad. NEMA- pressure relief valve are provided on the dome. Mild steel designs can
3R low voltage boxes are supplied over the LV terminals, with conduit be provided with optional stainless steel housings. All units are tested
openings on the lower tank of the transformer. per IEEE C57.13 and are supplied with certified test reports.

Units shown are rated -40 to +40 C amb, -50 C is an option.

Product Features Application


VT-Type SPOF Distribution Class oil-filled inductive voltage transformer 15kV-38kV / 110-200kV BIL dielectric levels available. 0.3%ZZ
with compact format, but robust performance expected accuracy on 2 secondaries and 5000VA thermal rating.
in larger units. Single or dual high creep and high strike
cycloaliphatic epoxy bushing designs. Line to ground (single bushing) or line to line (two bushing design) for
pole or platform mounting for metering and relaying.

VT-Type POF Substation Class oil-filled inductive voltage transformer 25kV-115kV / 150kV-550kV BIL dielectric levels available. 0.3%ZZ
with shield graded insulation. High creep and high strike accuracy on 2 secondaries and up to 7500VA thermal rating.
reliable cycloaliphatic epoxy bushing at 69kV and lower,
porcelain at 115kV (with polymer available as an option). Line to ground (one bushing) or line to line (two bushing design
available 69kV and lower) for metering and relaying.

VT- Type UT Substation Class oil-filled inductive voltage transformer 138kV-525kV / 650kV-1550kV BIL dielectric levels available. 0.3%ZZ
with shield graded insulation. High creep and high strike accuracy on 2 or 3 secondaries and up to 5000VA Thermal.
reliable porcelain (polymer available) insulators.
Line to ground applied single bushing design for metering and
relaying.

CVT- Type D Substation Class oil-filled capacitive voltage transformer 69kV-525kV / 350kV-1550kV BIL dielectric levels available. 0.3%Z
with capacitive divider for isolation from the high voltage accuracy on 2 or 3 secondaries and up to1200VA thermal rating.
circuit. Units supplied in porcelain insulators (polymer as
an option) with hermetically sealed capactitor stacks. Line to ground applied single bushing design for voltage
measurement or carrier communication.

Station Service VT- Substation Class oil-filled station service voltage 46kV-345kV / 250kV-1300kV BIL dielectric levels available. Power
Type SSVT transformer with high creep and high strike reliable ratings of 25kVA, 50kVA, 100kVA, or 167kVA (333kVA at some
porcelain insulators (polymer available). Power windings voltage levels).
with HV transformer design with graded insulation and
ground shield between HV and LV circuit. 120/240VAC power output offered with optional voltage measuring
windings for station service control power or rural electrification.

Station Service VT- Substation class oil-filled station service voltage 46kV-170 kV / 250KV -750kV BIL dielectric levels, 50/60 HZ available
Type SSMV transformer with medium voltage secondary, high creep Power ratings of 100 KVA , 125KVA, 167KVA and 200KVA at 7200V
and high strike porcelain insulators (polymer available). / 6600V.
Power windings with HV graded insulation and ground
shield between HV and LV windings. Measuring windings not offered in this class.

CT-Type SCOF Distribution Class oil-filled current transformer with 15kV-38kV / 110kV-200kV BIL dielectric levels available. 0.3B1.8 or
compact form and robust performance expected in larger up to C800 accuracy for one or two secondary core/coils.
units. Two high creep and high strike porcelain bushings.
Maximum primary current 1200A rating. Ratios from 5:5 to 1200:5.
75X short-circuit rating for metering or relaying on pole or platform
mounting.

CT- Type COF Substation Class oil-filled top core current transformer for 25kV-161kV / 150kV-750kV BIL dielectric levels available. , 0.3B1.8
metering or relaying application. Porcelain insulator with or up to C800 accuracy for up to three secondary core/coils.
high creep and high strike design (polymer as an option).
Maximum primary current 3200A rating. Ratios from 5:5 to 3000:5.
150X short-circuit rating available for metering or relaying.
Product Features Application
CT-Type CA Substation class EHV oil-filled top core current transformer 230kV-525kV / 1050kV-1800kV BIL dielectric levels available.
for metering or relaying application with porcelain insulator 0.3B1.8 or C800 accuracy for up to six secondary core/coils.
(polymer insulators available on some designs).
Maximum primary current 5000A rating. Ratios from 5:5 to 5000:5.
80X short-circuit for metering or relaying.

CT-Type CXM Special high accuracy wide measurement range oil-filled 25kV-525kV / 150kV-1800kV BIL dielectric levels available.
top core current transformer for metering extremely wide 0.15sB1.8 accuracy from 0.5% to 400% of nominal current rating
load swings in the same 0.15% accuracy class. Range is (0.3%B1.8 down to 0.25% of nominal current).
provided by special materials in Type COF and CA series.
Design uses the type COF and CA housings. Rating factor available

Document Number - HVITlinecard / February 2016


to 4.0. 80X short-circuit rating for wide range metering.

CT/VT-Type JS Distribution Class oil-filled current/voltage combined 15kV-38kV / 110kV-200kV BIL dielectric levels available. 0.3B1.8
metering transformer with compact format. CT windings or up to C800 accuracy for up to two secondary CT core/coils.
combined with VT windings for metering for pole top or Includes two tapped 0.3%ZZ secondary VT windings.
platform mounting in substation.
Maximum primary current 1200A rating. Ratios from 5:5 to 1200:5.
75X short-circuit rating for metering.

CT/VT-Type JXM Distribution Class oil-filled high accuracy wide 15kV-38kV / 110kV-200kV BIL dielectric levels available. 0.15sB1.8
measurement range current/voltage combined metering accuracy from 0.5% to 400% of nominal current rating (0.3%B1.8
transformer with compact format. Special core/coil design down to 0.25% of nominal current), plus two 0.15% tapped
capable of measuring accurately over a wide current secondary VT windings.
swing.
Maximum primary current 1200A rating. 150X short-circuit rating
available for wide range metering.

CT/VT-Type MVCT Distribution Class three phase oil-filled current/voltage 15kV-46kV / 110kV-250kV BIL dielectric levels available. 0.3B1.8
combined metering transformer with compact format. or C800 accuracy for per phase CT core/coil, plus two tapped
CT windings combined with VT windings for three phase secondary VT windings per phase.
metering.
Maximum primary current 1200A rating. Ratios from 5:5 to 1200:5.
75X short-circuit for metering or relaying.

CT/VT-Type MXM Distribution Class three phase oil-filled high accuracy wide 15kV-46kV / 110kV-250kV BIL dielectric levels available. 0.15sB1.8
measurement range current/voltage combined metering accuracy from 0.5% to 400% of nominal current rating (0.3%B1.8
transformer with compact format. Special core/coil design down to 0.25% of nominal current), plus two 0.15% tapped
capable of measuring accurately over a wide current secondary VT windings.
swing.
Maximum primary current 1200A rating. 150X short-circuit rating for
wide range metering.

CT/VT-Type KA Substation Class oil-filled current/voltage combined 46kV-230kV / 250kV-1050kV BIL dielectric levels available. 0.3B1.8
metering transformer for space savings. CT windings or up to C800 accuracy for CT core/coil, plus two tapped 0.3%ZZ
combined with VT windings for metering for platform secondary VT windings.
mounting in substation.
Maximum primary current 4000A rating. Ratios from 5:5 to 3000:5.
80X short-circuit rating for metering or relaying.

CT/VT-Type KXM Substation Class oil-filled high accuracy wide 46kV-230kV / 250kV-1050kV BIL dielectric levels available.
measurement range current/voltage combined metering 0.15sB1.8 accuracy from 0.5% to 400% of nominal current rating
transformer for space savings. Special design capable of (0.3%B1.8 down to 0.25% of nominal current), plus two tapped
metering accurately over wide current swing. 0.15%Z secondary VT windings for wide range metering.

Special series-parallel multi-ratio high accuracy wide range Special series-parallel design with 200/300/400x400/600/80
design available for short lead times/stock availability 0x800/1200/1600:5 ratio and rating factors of 4.0/3.0/2.0 with
(subject to prior sale). 0.15%B1.8 on each ratio from 0.5% to Rating Factor current level.

ABB Inc.
High Voltage Products
High Voltage Instrument Transformers
Lexington, Kentucky USA
Phone: +1 (859) 219-6040
Fax: +1 (859) 223-2025

www.abb.com/highvoltage
email hvit@us.abb.com