1. ELECTRIC SHOCK SURVIVAL (COMPULSORY)
You have an Emergency where an electric shock may stun the victim and
stop his or her breathing, state your safety actions in the situation:
Of the Danger
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________
With all safety measures taken you now attempt Resuscitation in which you
had checked for the response, a gentle shake and shouted loudly but the
victim had not responded, state in sequence your resuscitation proceeds.
STEP ONE
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________
1 Prepared by PPL Regulatory Services Business Unit
STEP TWO
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________
STEP THREE
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________
STEP FOUR
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________
You check the carotid pulse for (time) ___ seconds and the pulse is absent,
you position your hand (state location) ___________________________________ to do
heart compression.
Single Operator
Give ____ heart compressions followed by ___ full quick ___________ without
interrupting the rhythm at the rate of _____ compression per minute.
Two Operators
Give ____ heart compressions followed by ___ full quick ___________ without
interrupting the rhythm at the rate of _____ compression per minute.
STEP SIX
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
Pass/Fail
VISUAL INSPECTION
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
________________________________________________________
2 Marks
EARTH CONTINUITY
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
2 Marks
INSULATION TEST
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
______________________________________________________________
2 Marks
METERING
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
______________________________________________________________
2 Marks
ENERGIZING THE INSTALLATION
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
___________________________________________________________________________________________________
____________________________________________________________________________
2 Marks
2 Marks
2 Marks
13. According to the rules, the use of PVC Water Pipe, or associated fittings of
non-metallic conduits in underground wiring as electrical conduit is
__________________________________.
2 Marks
2 Marks
15. Fault at the switchboard is the cause of receiving an electric shock from
metallic parts of an installation, what would be the possible cause?
___________________________________________________________________________________________________
___________________________________________________________________________________________________
________________________________________________
6 Prepared by PPL Regulatory Services Business Unit
2 Marks
16. Complete the single line diagram below of a supply arrangement comprising
Normal Power Supply, an Alternate Power Supply and Load Center
Switchboards of Non Essential (SW/BD 1) and Essential (SW/BD 2).
T/SW
PPL GEN.
SW/BD.1 SW/BD.2
5 Marks
17. Show by schematic diagram how you would connect up a 800/5-CT test
meter to an existing CT metering. Label all components.