AWS D1.1/D1.1M:2015 CLAUSE 6.

INSPECTION

Table 6.6
IQI Selection and Placement (see 6.17.7)
Equal T Equal T Unequal T Unequal T
10 in [250 mm] L < 10 in [250 mm] L 10 in [250 mm] L < 10 in [250 mm] L

IQI Types Hole Wire Hole Wire Hole Wire Hole Wire

Number of IQIs

Nontubular 2 2 1 1 3 2 2 1

ASTM Standard Selection E1025 E747 E1025 E747 E1025 E747 E1025 E747

Table 6.4 6.5 6.4 6.5 6.4 6.5 6.4 6.5

Figures 6.6 6.7 6.8 6.9

T = Nominal base metal thickness (T1 and T2 of Figures).


L = Weld Length in area of interest of each radiograph.

Note: T may be increased to provide for the thickness of allowable weld reinforcement provided shims are used under hole IQIs per 6.17.3.3.

213