THE FIBRWRAP COMPANY

Tyfo SEH-25A Composite


using Tyfo S Epoxy
DESCRIPTION TYPICAL DRY FIBER PROPERTIES
The Tyfo SEH-25A Composite is comprised of
Tyfo S Epoxy and Tyfo SEH-25A reinforcing Tensile Strength 470,000 psi (3.24 GPa)
fabric. Tyfo SEH-25A is a custom weave, uni- Tensile Modulus 10.5 x 106 psi (72.4 GPa)
directional glass fabric used in the Tyfo
Ultimate Elongation 4.5%
Fibrwrap System. The glass material is
orientated in the 0o direction with additional Density 0.092 lbs./in.3 (2.55 g/cm3)
glass cross fibers at 90 o. The Tyfo S Epoxy is
Weight per sq. yd. 14.9 oz. (505 g/m2)
a two-component epoxy matrix material.

USE
Tyfo SEH-25A Fabric is combined with Tyfo
epoxy material to add strength and ductility to COMPOSITE GROSS LAMINATE PROPERTIES
bridges, buildings, and other structures.
ASTM TYPICAL
ADVANTAGES
PROPERTY METHOD TEST VALUE DESIGN VALUE*
Good high temperature properties
Good low temperature properties Ultimate tensile strength in D-3039 75,625 psi (521 MPa) 60,500 psi (417 MPa)
Long working time primary fiber direction, psi (1.5 kip/in. width) (1.2 kip/in. width)
High elongation
Elongation at break D-3039 2.0% 1.76%
Ambient cure
100% solvent-free Tensile Modulus, psi D-3039 3.79 x 106 psi (26.1 GPa) 3.03 x 106 psi (20.9 GPa)
Rolls can be cut to desired widths prior to
shipping Ultimate tensile strength 90 D-3039 3,750 psi (25.8 MPa) 3,000 psi (20.7 MPa)
degrees to primary fiber, psi
COVERAGE
Approximately 1,350 sq. ft. (125.4m2) surface Laminate Thickness 0.02 in. (0.50 mm) 0.02 in. (0.50 mm)
area with 3 to 4 units of Tyfo S Epoxy and 1
roll of Tyfo SEH-25A Fabric when used with the * Design and specification values will vary based on individual project requirements and applicable safety factors. Contact Fyfe
Co. LLC engineers to determine appropriate specification values.
Tyfo Saturator.

PACKAGING
Order Tyfo S Epoxy in 55-gallon (208L) drums EPOXY MATERIAL PROPERTIES
or pre-measured units in 5-gallon (19L) Curing Schedule 72 hours post cure at 140o F (60o C).
containers. Order Tyfo SEH-25A Fabric
in 54 x 300 lineal foot (1.4m x 91.4m) rolls. ASTM TYPICAL
Typically ships in 12 x 13 x 64 (305mm x PROPERTY METHOD TEST VALUE*
330mm x 1626mm) boxes. o
Tg 140 F (60o C) ASTM D-4065 180o F (82o C)
EPOXY MIX RATIO Post Cure (24 hours)
100.0 component A to 42.0 component B
by volume. ( 100 component A to 34.5 component Tensile Strength1, psi ASTM D-638 10,500 psi
B by weight.) Type 1 (72.4 MPa)

SHELF LIFE Tensile Modulus, psi ASTM D-638 461,000 psi


Epoxy - two years in original, unopened and Type 1 (3.18 GPa)
properly stored containers.
Fabric - ten years in proper storage conditions. Elongation Percent ASTM D-638 5.0%
Type 1
STORAGE CONDITIONS
Store at 40o to 90o F (4o to 32 o C). Avoid 17,900 psi
Flexural Strength, psi ASTM D-790
freezing. (123.4 MPa)
Store rolls flat, not on ends, at temperatures
below 100o F (38o C). Avoid moisture and water 452,000 psi
Flexural Modulus, psi ASTM D-790
contamination. (3.12 GPa)
CERTIFICATE OF COMPLIANCE
1
Testing temperature: 70o F (21o C) Crosshead speed: 0.5 in. (13mm)/min. Grips Instron 2716-0055 - 30 kips
Will be supplied upon request, complete * Specification values can be provided upon request.
with state and federal packaging laws
with copy of labels used.
Material safety data sheets will be supplied
upon request.
Possesses 0% V.O.C. level.
12/05 Tyfo SEH-25A
HOW TO USE LIMITATIONS TYFO S COMPOSITE SAMPLES
THE TYFO S COMPOSITE SYSTEM Minimum application temperature of the epoxy Please note that field samples are to be cured
is 40o F (4o C). DO NOT THIN, solvents will for 48-hours at 140o F (60o C) before testing.
prevent proper cure. Testing shall be in accordance with ASTM
DESIGN D-3039 and Fyfe Co. LLC sample preparation
The Tyfo System shall be designed to meet and testing procedures.
specific design criteria. The criteria for each CAUTION!
project is dictated by the engineer of record and
SHIPPING LABELS CONTAIN
any relevant building codes and/or guidelines.
State specification number with modifications,
The design should be based on the allowable
COMPONENT A - Irritant: Prolonged if applicable
strain for each type of application and the
contact to the skin may cause irritation. Component designation
design modulus of the material. The Fyfe Co.
Avoid eye contact. Type, if applicable
LLC engineering staff will provide preliminary
Manufacturers name
design at no obligation.
Date of manufacture
COMPONENT B - Irritant: Contact with skin Batch name
may cause severe burns. Avoid eye contact. State lot number, if applicable
INSTALLATION Product is a strong sensitizer. Use of
Tyfo System to be installed by Fyfe Co. LLC
Directions for use
safety goggles and chemical resistant gloves Warnings or precautions by law
trained and certified applicators. Installation
recommended. Remove contaminated
shall be in strict compliance with the Fyfe Co.
clothing. Avoid breathing vapors. Use
LLC Quality Control Manual. KEEP CONTAINER TIGHLY CLOSED.
adequate ventilation. Use of an organic vapor
respirator recommended. NOT FOR INTERNAL CONSUMPTION.
SURFACE PREPARATION CONSULT MATERIAL SAFETY DATA SHEET
The required surface preparation is largely (MSDS) FOR MORE INFORMATION.
SAFETY PRECAUTIONS KEEP OUT OF REACH OF CHILDREN.
dependent on the type of element being Use of an approved particle mask is
strengthened. In general, the surface must FOR INDUSTRIAL USE ONLY.
recommended for possible airborne particles.
be clean, dry and free of protrusions or Gloves are recommended when handling
cavities, which may cause voids behind fabrics to avoid skin irritation. Safety glasses
the Tyfo composite. Column surfaces are recommended to prevent eye irritation.
that will receive continuous wraps typically
require only a broom cleaning. Discontinuous
wrapping surfaces (walls, beams, slabs, etc.) FIRST AID
typically require a light sandblast, grinding or In case of skin contact, wash thoroughly with
other approved methods to prepare for bonding. soap and water. For eye contact, flush
Tyfo FibrAnchors are incorporated in some immediately. For respiratory problems,
designs. The Fyfe Co. LLC engineering staff will remove to fresh air. Wash clothing before
provide the proper specifications and details based reuse.
on the project requirements.
CLEANUP
MIXING Collect with absorbent material, flush with
For pre-measured units in 5-gallon (19L) water. Dispose of in accordance with local
containers, pour the contents of component disposal regulations. Uncured material can be
B into the pail of component A. For drums, removed with approved solvent. Cured materials
premix each component: 100.0 parts of can only be removed mechanically.
component A to 42.0 parts of component B by
volume (100 parts of component A to 34.5 parts
of component B by weight). Mix thoroughly for
five minutes with a Tyfo low speed mixer at
400-600 RPM until uniformly blended.

APPLICATION
Feed fabric through the Tyfo Saturator and
apply using the Tyfo wrapping equipment or
approved hand methods. See data sheet on this
equipment. Hand saturation is allowable,
provided the epoxy is applied uniformly and
meets the specifications.

Fyfe Co. LLC


The Fibrwrap Company
Nancy Ridge Technology Center
6310 Nancy Ridge Drive, Suite 103, San Diego, CA 92121
Tel: 858.642.0694 Fax: 858.642.0947
E-mail: info@fyfeco.com Web: http://www.fyfeco.com

Statement of Responsibility: The technical information and application advice in this publication is based on the present state of our best scientific and practical
knowledge. As the nature of the information herein is general, no assumption can be made as to the products suitability for a particular use or application, and no
warranty as to its accuracy, reliability or completeness, either expressed or implied, is given other than those required by State legislation. The owner, his representative
or the contractor is responsible for checking the suitability of products for their intended use. Field service, where provided, does not constitute supervisory responsibility.
Suggestions made by the Fyfe Co., either verbally or in writing, may be followed, modified or rejected by the owner, engineer or contractor since they, and not the Fyfe
Co., are responsible for carrying out procedure appropriate to a specific application.
12/05 Tyfo SEH-25A Patented in U.S.A., Canada, and other countries. Copyright 2002-2005 Fyfe Co. LLC 159-05

Das könnte Ihnen auch gefallen