Piston Pumps
Revised 11/01/97
Maximum Adjustable Stop S Option Valve Block Table
Pump RH LH
Type
F11C 928633 928681
913341 Locknut M11C 928634 928682
Torque 25-50 N.m. SF11C 928620 928669
(18-37 lb. ft.)
SM11C 928621 928670
F11CT 860848 860857
860741 Adj. screw M11CT 860849 860858
Standard C/CM/CMV/CV/IC
Pump control (see controls pages)
941441 Shaft spacer kit
388153 Bearing S/A Valve plate (see table)
396093 O-ring 526631 Gasket Rotating group kit (See table)
(2 Reqd)
Valve block
(see table)
857722 Body
860750 Adj. screw
473765 Screw (4 Reqd)
Torque 31-37 N.m. (23-28 lb. ft) 860749 Plug
Torque 97-106 N.m.
857672 Spool (71-78 lb. ft.)
396096 O-Ring
860747 Nut
Torque 14-20 N.m.
(10-14 lb. ft.)
627391 Plug
Torque 29-32 N.m.
(21-24 lb. ft.)
913454 Spool
860653 Body
177969 O-ring (5 reqd)
577639 Sleeve
262356 O-ring
248845 Pin 932716Connector
932716 Retainer Ring Torque 54-59 N.m
(Screw into bottom of thread) (73-80 lb. ft.)
Rear
Pump
Thrudrive
Adapter location
O-Ring
(See table) (See table)
A Thrudrive
Notes:
1.F type equal SAE threads
2. M type equal metric threads
3. B and C thru-drives created from
A thru-drive pump with B or C
thru-drive adapter kit installed.
4. All screws/O-rings are included with
each kit to convert from A to
B or C thru-drive unit.
Typical Cross Section
Control Piston
Control Rod
Valve Block
Port #1
Valve Block
Port #2
Bias Rod
Position outer shaft
Bias Piston
seal facing shaft end
Spring
Position inner shaft
seal facing bearing Note
Parts are shown as installed for right
hand rotation. For left hand rotation,
install control rod and control piston
in valve block port #2. Install bias
rod, bias piston and spring in valve
block port #2.
Pump Startup
When initially starting the pump, remove After the pump is primed, tighten the
Make sure the reservoir and circuit are all trapped air from the system. This can loose outlet connections, then operate
clean and free of dirt and debris prior be accomplished by loosening the pump for five to ten minutes (unloaded) to re-
to filling with hydraulic fluid. outlet fittings or connections before move all trapped air from the circuit. If
starting the pump, or by using an air reservoir has a sight gage, make sure
Fill the reservoir with filtered oil to a
bleed valve. All inlet connections must the fluid is clearnot milky.
level sufficient to prevent vortexing at
be tight to prevent air leaks.
suction connection to pump inlet. It is
Add fluid to the reservoir up to the prop-
good practice to clean the system by Once the pump is started, it should er fill level.
flushing and filtering using an external prime within a few seconds. If the pump
slave pump. does not prime, check to make sure that
there are no air leaks in the inlet line
Before starting the pump, fill with fluid
and connections. Also check to make
through one of the ports. This is par-
sure that trapped air can escape at the
ticularly important if the pump is above
pump outlet.
the fluid level of the reservoir.
Model Code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Printed in U.S.A.
Eaton Eaton Eaton
Fluid Power Group Fluid Power Group Fluid Power Group
Hydraulics Business USA Hydraulics Business Europe Hydraulics Business Asia Pacific
14615 Lone Oak Road Route de la Longeraie 7 11th Floor Hong Kong New World Tower
Eden Prairie, MN 55344 1110 Morges 300 Huaihai Zhong Road
USA Switzerland Shanghai 200021
Tel: 952-937-9800 Tel: +41 (0) 21 811 4600 China
Fax: 952-294-7722 Fax: +41 (0) 21 811 4601 Tel: 86-21-6387-9988
www.eaton.com/hydraulics Fax: 86-21-6335-3912