Sie sind auf Seite 1von 3

APLIKASI MICROCONTROLLERS DAN JARINGAN

ETHERNET UNTUK PEMANTAUAN MOTOR POMPA KALI


SOLO 1

007
ABSTRACT23

Kali solo 1 pumps is dedicated to serve as input water treatment process for oil
refineries as well as for office and home consumption. The location is right on
the banks of the Bengawan Solo river and located at depth of 10 meters form
surface and relatively long distance from the area of monitoring room, so that
during this time the operators was very difficult to monitor real time condition of
the pump. There are has already three pumps installed, each with capacity of
250 m3/minute with power consumption of 55 kW at 1475 rpm rotation. In order
to field workers can at any time monitor pump condition, that is will require the
application by a using a microcontroller and ethernet network so that the
constraints of distance and time and data erors can be avoided or even
eliminated and can predict the motor maintenance activities. This article will
explain the use microcontroller application to monitor the rotation of the motor
pump in the real time by utilizing the local computer network based on fiber
optic. It is consists of three major devices namely a rotation sensor,
microcontrollers Atmega 128, server and network type of fiber.
Process and Instrumentation Diagram Development

The process and instrumentation diagram (P&ID as it often called) represents a


document that can take on many different forms depending upon the following
factors :

1) Nature of the process being depicted. The more complicated the process,
or the more one process is interconnected to other portions of the P&ID,
the more complex the P&ID will become.
a. The individual or firm perfoming the design work. Some firms do not
feel the need to develop P&IDs. This approach is used to achieve
economies on system design.
b. Design philosophy. Some design philosopies include P&IDs as an item
issued with the instrumentation or electrical design (developed at the
middle or end of the project). Other design philosopies allow the P&IDs
to be used as the basis for all other design disciplines. In this
philosophy, the electrical, mechanical, and piping engineers on a
project would start their work once the P&IDs are complete.
2) Intended audience once the design is complete.
NO POL KAPASITAS TUJUAN JARAK SOPIR UANG SAKU
TRUCK
K 21335 E 7000 L SEMARANG 140 SUPARMIN Rp. 1.400.000
K 21333 E 5000 L PURWODADI 70 RAKA Rp. 700.000
K 21336 E 8000 L TUBAN 50 SARDI Rp. 500.000
K 21334 E 6000 L REMBANG 60 WASIS Rp. 600.000