FEATURES
DN15-40
Nominal Diameter DN mm 15 20 25 32 40
Nominal flow rate Q3 m3/h 2.5 4 6.3 10 16
Minimum flow rate Q1L/h 10 6.25 16 10 25.2 15.75 40 25 64 40
Pressure loss 63 63 63 40 40
Body length Lmm 165 190 260 260 300
Length with coupling L2mm 255 290 360 360 400
Calculator length of L1mm 97
Height H1mm 31 28 25 29 36
Height Hmm 91 91 91 128 139
Calculator width Wmm 90
Screw thread(inch) G3/4B G1B G1 1/4B G1 1/2B G2B
Screw thread of coupling (inch) R1/2 R3/4 R1 R1 1/4 R1 1/2
Dynamic range(Q3/Q1) 250:1
Working pressure 1.6MPa(other can be customized
Max volume (m3) 99999.999999
IP grade IP68
Medium temperature T30,T50,T70 (T30 default)
Power supply 3.6V lithium Battery
Battery Lifetime 10 years
Installation At any angle
IP Grade IP68
Environment class Class C
Electromagnetic class E1
Medium Conduit is fully charged with water
DN50-600
DN mm 50 65 80 100 125 150 200 250 300 350 400 500 600
Q4 m3/h 31.25 50 78.75 125 200 312.5 500 787.5 1250 1250 2000 3125 5000
Q3 m3/h 25 40 63 100 160 250 400 630 1000 1000 1600 2500 4000
Q1 m3/h 0.063 0.1 0.158 0.25 0.4 0.6255 1 1.575 2.5 2.5 4 6.25 10
Staring 0.01 0.02 0.03 0.05 0.08 0.1 0.2 0.3 0.4 0.6 0.75 1.2 1.8
flow
L mm 200 200 225 250 250 300 350 450 500 500 600 600 800
L1 mm 120 120 120 120 120 120 120 120 120 120 120 120 120
B mm 172 190 205 230 250 285 340 405 460 520 580 715 840
D mm 165 185 200 220 250 285 340 405 460 520 580 715 840
H1 mm 65 70 90 100 125 130 170 203 230 260 290 358 420
H mm 245 250 275 290 380 400 470 530 580 640 695 815 925
W mm 123
22 26 30 33 36
IP grade IP68
Medium T30,T50,T70 (T30 default)
temperature
Power supply 3.6V lithium Battery(24DC, 220VAC customized)
Battery 10 years DN250 6 years
Lifetime
Installation At any angle
IP Grade IP68; IP65 for 24DC, 220VAC
Environment Class C ( Class B and I for optional)
class
Electromagneti E1
c class
Medium Conduit is fully charged with water
Remark:
Q1: Minimum flow rate Q2: Transitional flow rate
Q3: Permanent flow rate Q4: Overload flow rate
Application
Reading Map
Model Selection
Pressure Range
16 1.6 MPa
25 2.5MPa
S Special, pls clarify
Power supply
B Battery Supply
DC 24VDC
AC 95-265VAC
Communication type
MW Wired M-bus
LM Wireless M-Bus(Testing)
2 RS485(Modbus protocol)
S Special, pls clarify
Connection Type
C Copper
D DIN (En13757)
A ANSI
S Special
Pipe material
C Cast iron
S Stainless Steel
Remark:
DN15-40 Copper, thread;
DN50-100 Cast Iron, Flanges;
DN125-600 Carbon Steel and Flange type