Beruflich Dokumente
Kultur Dokumente
engr.muhammadnoman@gmail.com
+92 346 8482210 PEC Membership: Regd: ELECT/40886
Mailing Address: House # 234 Mohallah Malik Nasarullah Jan, Rawail Gali, Nouthia Qadeem, Saddar Cantt, Peshawar.
Skype ID: engr.muhammadnoman CNIC#: 17301 7442225 7
Date of birth: 22nd March, 1991 Marital Status: Single
Passport #: AG9202251 (Validity: 21 August 2018 )
PERSONAL SUMMARY
A competent electrical engineer with a comprehensive knowledge of detailed Engineering design, testing and
commissioning of electrical power systems & components to required specifications, focusing on safety, reliability,
quality and sustainability. Presently I am working with a consulting firm on their 4 Hydropower projects funded by Asian
Development Bank through Renewable Energy Development Sector Investment Program (REDSIP) with net worth of
$92 Million US Dollar.
ACADEMIC QUALIFICATION
Qualification Institute Passed In Marks
Bachelors in Electrical Power University Of Engineering Sept 2013 81.00 %
Engineering And Technology Peshawar (3.24/4 CGPA)
Pre Engineering / A Level Islamia College University July 2009 81.64 %
Peshawar (898/1100)
Matriculation / O Level Islamia Collegiate School July 2007 87.11 %
Peshawar (784/900)
Electrical Engineer Electra Consultants Jan 2017 Present 1 Month Koto HPP (40.8MW)
Page 1 of 3
DC system calculations in accordance with IEEE-Std 485 -1997.
Detailed Design review of System Protection & Metering.
Design review of other electrical design calculations, such as Short Circuit, Cable selection,
Turbine-Generator Unit Selection, Electrical Load Calculation, Earthing Calculations etc.
Design review of Lightning Protection layout for 132 kV outdoor Switchyard.
Page 2 of 3
Design and selection of surge arrestors for protection of transmission lines against lightning stokes.
Detailed design review of setting calculations for Overcurrent protection (IDMT, Definite & Instantaneous) for
Step-Up Main Transformers and Transmission lines Feeder relay PCS 9611.
Design calculations and settings of Earth Fault protection for Transmission lines.
Testing and commissioning of power house bridge crane as per FEM standards
Powerhouse building and Spillway AC lighting design as well design of emergency lighting on DC system.
Performed detailed grounding mesh calculations for powerhouse as per IEEE Std 80- 2000.
Performed short circuit calculations as per IEC 60909.
Detailed study and approval of design drawings, specifications and technical documents.
Performed UPS & battery sizing design & calculations in accordance with IEEE 485-1997.
Detailed design calculations for 230 V & 400 V distribution system as well as cable sizing as per IEC 60364.
Detailed design calculations for generator protection as per IEEE C37.101
Design of structural lightning protection as per BS EN 62305.
Design analysis for liquid immersed and dry type transformers as per IEC-76, IEC-600726.
Design review of 0.4 kV, 6.3 kV and 11 kV switchgear panels.
Performed electrical design calculations for the distribution transformers and standby diesel generators
Performed design review of power transformer installation drawings & lightning protection.
Performed selection and sizing of lightning arresters as per IEC & IEEE standards.
Conducted site visits to determine and validate field dimensions.
Processing of Commercial Invoices of equipment imported from abroad. Check and verify the consignments arrived at
site from abroad.
Detailed design review of internal & external lighting schemes.
Verification of interim payment certificates (IPCs) of the contractors.
Meetings and frequent letter correspondence with Client and Contractor to settle down the issues regarding design
services and installation of equipment at site
COMPUTER PROFICIENCY
MS office, AutoCAD, ORCAD 10.5, PSPICE, C, C++, MATLAB (Simulink),Proteus.
LANGUAGES
English, Urdu, Pashto
REFERENCES
Shall be provided on request.
Page 3 of 3