Beruflich Dokumente
Kultur Dokumente
1 pole 10 A, 2 pole 8 A
Features
1 C/O or 1 N/O contact, 10 / 16 A
Pinning 3,5 or 5 mm
2 C/O contacts ( 409 03 )
4 kV / 8 mm coil-contact ( 409 07 )
Applications
Power supplies, domestic appliances, heating controls
Z (409 07 only)
F0249-A
Technical data of approved types on request
Contact data
Configuration 1 C/O 1 N/O 2 C/O
Type of contact single contact
Rated current pinning 3.5/5 mm 10/16 A 10/16 A -/8 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Max. breaking voltage DC 250 Vdc
Maximum breaking capacity AC 4000 VA 4000 / 2500 VA 2000 VA
Make current (max. 4 s at duty cycle 10%) 20 A 20 / 12 A 10 A
peak inrush current 20 ms 20 A 20 / 16 A 16 A
Contact material AgCdO
Contact ratings
Type Load Operations
409 03 8 A, 250 Vac, resistive 2x105
409 04 10 A, 250 Vac, resistive 2x105
409 06 16 A, 250 Vac, resistive 2x105
409 07 16 A, 250 Vac, resistive 2x105
Coil data
Nominal voltage DC coil 2.5...110 Vdc
Nominal coil power DC coil 0.6...0.8 W
Operate category c
Insulation Dimensions
Dielectric strength coil-contacts 2500 Vrms 4000 Vrms (40904/07) View on solder pins
open contact circuit 1000 Vrms Dimensions in mm
Clearance / creepage 4 mm 8 / 8 mm (40904/07)
Insulation to VDE 0110b (2/79) 1 C/O, 2 C/O contacts
Insulation category / reference voltage C / 250
Tracking resistance of relay base PTI 250
Other data
Flammability class according to UL 94 V-0
Coll insulation system according to UL 1446 F
Ambient temperature DC-coil -20...+70 C
Mechanical life DC-coil 30x106 operations S0273-AK
Max. switching rate at rated- / minimum load 15 min-1 / 1200 min-1
Operate- / release time typ. 10 / 3 ms 1 N/O contact
Bounce time typ. 3 ms
Vibration resistance 20 g (30...300 Hz)
Shock resistance (destruction) 100 g
Category of protection (IEC 61810) RT II - flux proof
Relay weight 15 g
Packaging unit 25 / 250 pcs.
1 C/O contact
S0468-AA
Edition: 01/2004
Power PCB Relay RT1
1 pole 12 / 16 A, DC- or AC-coil
Features
1 C/O or 1 N/O contact
Sensitive coil 400 mW
5 kV / 10 mm coil-contact, Protection class II
Ambient temperature 85C (DC-coil)
Height 15.7 mm
Sockets with PCB-type or screw-type terminals
Gold plated contacts available
RoHS compliant (Directive 2002 / 95 / EC) as per
product date code 0413
Applications
Boiler control, timers, garage door control, POS automation,
F0144-B
interface modules
VZBSF
Technical data of approved types on request
Contact data
Configuration 1 C/O contact or 1 N/O contact
Type of contact single contact
Rated current 12 A 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Maximum breaking capacity AC 3000 VA 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A 30 A
Contact material AgNi 90/10, AgNi 90/10 gold plated
Contact ratings
Type Load Operations
RT314 16 A, 250 Vac, cos=1, N/C contact 53x103
RT314 20 A, 250 Vac, 85C, N/O contact, UL508 6x103
RT314 1000 W, 250 Vac, incandescent lamps 1.2x103
RT314 10 A, 250 Vac, cos=0.6, C/O contact 2x105
RT314 5 A / 2 A, 250 Vac, cos=1, tumble-drier motor, N/O contact 1.1x106
RT314 0.26Apeak / 0.01 A, 230 Vac, cos=0.38, valve, N/O contact 7.6x106
RT314 3
/4 hp, 240 Vac; 1/3 hp, 120 Vac
RT314 Pilot duty B300
Coil data
Nominal voltage DC coil 5...110 Vdc Rights to change data / design reserved
AC coil 24...230 Vac
Nominal coil power DC coil 400 mW
AC coil 0.75 VA
Operate category 2/b
Edition: 07/2004
Insulation
Dielectric strength coil-contacts 5000 Vrms
open contact circuit 1000 Vrms
Clearance / creepage 10 / 10 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
Tracking resistance of relay base CTI 250
Other data
RoHS - Directive 2002 / 95 / EC compliant as per product date code 0413
Flammability class according to UL 94 V-0
Coil insulation system according to UL 1446 Class F
Ambient temperature DC-coil -40...+85 C Dimensions
AC-coil -40...+70 C Dimensions in mm
Mechanical life DC-coil >30x106 operations
AC-coil >10x106 operations
Max. switching rate at rated- / minimum load 6 min-1 / 1200 min-1
Operate- / release time DC-coil typ. 7 / 3 ms
Bounce time N/O contact/N/C contact typ. 1 / 3 ms
Vibration resistance N/O / N/C contact 20 / 5 g, 30...500 Hz
Shock resistance (destruction) 100 g
Category of protection (IEC 61810) RT II, RT III
Relay weight 14 g
Packaging unit 20 / 500 pcs. S0272-AB
Features
2 C/O or 2 N/O contacts
Sensitive coil 400 mW
DC- or AC-coil
5 kV / 10 mm coil-contact
Protection class II
Height 15.7 mm
Sockets with PCB-type or screw-type terminals
RoHS compliant (Directive 2002 / 95 / EC) as per
product date code 0413
Applications
Domestic appliances, heating control, emergency lighting, modems
F0149-B
VZB
Technical data of approved types on request
Contact data
Configuration 2 C/O contact or 2 N/O contact
Type of contact single contact
Rated current 8A
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Maximum breaking capacity AC 2000 VA
Make current (max. 4 s at duty cycle 10%) 15 A
Contact material AgNi 90/10, AgNi 90/10 gold plated
Contact ratings
Type Load Operations Standard
RT 424 4 A, 230 Vac, cos=0.6 1.5x105
RT 424 6 (2) A, 250 Vac, on the N/O- N/C contact VDE 0631
RT 424 1/2 hp / 240 Vac, 1/4 hp / 120 Vac 6x103 UL 508
Coil data
Nominal voltage DC coil 5...110 Vdc
AC coil 24...230 Vac
Nominal coil power DC coil 400 mW Rights to change data / design reserved
AC coil 0.75 VA
Operate category 2/b
Insulation
Dielectric strength coil-contacts 5000 Vrms
open contact circuit 1000 Vrms
adjacent contacts 2500 Vrms
Clearance / creepage 10 / 10 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
2 C/O contacts
Dimensions
Dimensions in mm
Edition: 07/2004
S0163-BJ
2 N/O contacts
S0272-AA
S0163-BK
Edition: 07/2004
Features
Specifically designed to handle high inrush currents
Tungsten prerun contact
500 A / 10 ms inrush peak current
4 kV / 8 mm coil-contact
meets protection class II requirements
Applications
Dimmer switches, movement sensors, filament loads, halogen
bulbs, motors and electrovalves
Z (409 47 only)
F0249-A
Technical data of approved types on request
Contact data
Configuration 1 N/O contact
Type of contact single contact
Rated current 10 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Maximum breaking capacity AC 2500 VA
Make current (max. 4 s at duty cycle 10%) 16 A
peak inrush current 10 s / 20 ms 500 / 120 A
Contact material W (prerun contact) + AgCdO
Contact ratings
Type Load Operations Standard
409 10 A, 250 Vac, resistive 2.5x105
409 1300 W, fluorescent lamps, 140 F 3x104
409 2500 W, incandescent lamps 3x104
409 1000 W, Dulux lamps, 140 F 3x104
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 1000 Vrms
Clearance / creepage 8 / 8 mm
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
Tracking resistance of relay base PTI 250 PCB layout / terminal assignment
Bottom view on solder pins
Dimensions in mm
Dimensions
Dimensions in mm
S0273-AI
Features
Specifically designed to handle high inrush currents
1 N/O contact
DC- or bistable version
4 kV / 8 mm coil-contact
Applications
Lighting controls, filament loads, motors and electrovalves
Z (409 57 only)
F0249-A
Technical data of approved types on request
Contact data
Configuration 1 N/O contact
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Rated voltage / max.breaking voltage DC 250 Vdc / 250 Vdc
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Peak inrush current 120 A
Contact material AgSnO2
Contact ratings
Type Load Operations Standard
409 57 / 77 16 A, 250 Vac, cos=1 1.5x105
409 57 / 77 1200 W, fluorescent lamps, 100 F 3x104
409 57 / 77 2500 W, Filament lamps 3x104
409 57 / 77 800 W, Dulux lamps, 100 F 2x104
409 57 / 77 capacitive load 10 A, 140 F 3x104 EN 61058-1
1 N/O 5 mm
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 2000 Vrms
Clearance / creepage 8 mm S0468-au
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
Tracking resistance of relay base PTI 250
Dimensions
Dimensions in mm
Other data
Flammability class according to UL 94 V-0
Ambient temperature DC-coil -20...+70 C
Mechanical life DC-coil 30x106 operations
Max. switching rate at rated- / minimum load 15 min-1 / 1200 min-1
Operate- / release time typ. 10 / 3 ms
Bounce time typ. 3 ms
Vibration resistance 20 g (30...300 Hz)
Shock resistance (destruction) 100 g
Category of protection (IEC 61810) RT II - flux proof
Relay weight 15 g
Packaging unit 25 / 250 pcs. S0273-AI
Features
1 N/O contact
120 A / 20 ms inrush peak current
4 kV / 8 mm coil-contact
RoHS compliant (Directive 2002 / 95 / EC) as per
product date code 0404
Applications
Lighting control, timers, motor control, building automation
VZ H
F0147-A
Technical data of approved types on request
Contact data
Configuration 1 N/O contact
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Peak inrush current 120 A
Contact material AgSnO2
Contact ratings
Type Load Operations Standard
RP3SL 12 A, 250 Vac, cos=1 3x105
RP3SL TV 8 25x103 UL 508
RP3SL 2500 W, 230 Vac, halogen lamps >104
RP3SL 1000 W, 250 Vac, incandescent lamps 2.3x105
RP3SL 3000 W, 250 Vac, incandescent lamps 3.6x104
RP3SL 1500 VA, fluorescent lamps 163 F 104
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 2000 Vrms
Clearance / creepage 8 / 8 mm PCB layout / terminal assignment
Insulation to IEC 60664 Bottom view on solder pins
Voltage rating 250 V Dimensions in mm
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
Rights to change data / design reserved
Dimensions
Dimensions in mm
S0273-AC
Features
1 N/O or 1 N/C contact
16 A rated current
Switching capacity 4000 VA
Coil power 360 mW
4 kV / 8 mm coil-contact, insulation to VDE 0631 and 0700
Ambient temperature up to 125C
Faston-terminals for load side
Applications
White goods appliances, oven control, electric heating, power
suppplies, air conditionning, motors, magnetic valves
F0248-AA
V BSZ
Technical data of approved types on request
Contact data
Configuration 1 N/O contact or 1 N/C contact
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Contact material AgCdO
Contact ratings
Type Load Operations
N/O cont. 16 A, 250 Vac, resistive, 125 C 1x105
N/O cont. 12 A, 250 Vac, resistive, 70 C 4.5x105
N/C cont. 16 A, 250 Vac, resistive, 125 C 1.5x105
N/O cont. 10 A, 400 Vac, resistive, 125 C 5x104
N/O cont. 12 A, 250 Vac, cos=0.6, 125 C 5x104
Coil data
Nominal voltage 6...60 Vdc
Nominal coil power 360 mW
Operate category 1/b
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 1000 Vrms
Clearance / creepage 8 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
Tracking resistance of relay base PTI 250
Faston Power Relay 410 63 125C
1 pole 16 A
S0256-CB
1 N/C contact
S0282-AB
S0256-CC
Features
1 N/O bridging contact
Contact gap > 3 mm
16 A rated current
Switching capacity 4000 VA
Coil power 360 mW
4 kV / 8 mm coil-contact, insulation to VDE 0631 and 0700
Ambient temperature up to 85C
Faston-terminals for load side
Applications
Washing machines, tumble dryers, absolute safe power supply
disconnection in other domestic applications
VZ
F0248-AB
Contact data
Configuration 1 N/O contact
Type of contact single contact, bridging contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 20 A
Contact material AgNi
Contact gap >3 mm
Contact ratings
Type Load Operations
410 83 16 A, 250 Vac, resistive, 85 C 3x104
410 83 10 A, 250 Vac, resistive, 85 C 1x105
410 83 10 A, 400 Vac, resistive, 85 C 1x105
Coil data
Nominal voltage 6...60 Vdc
Nominal coil power 360 mW
Operate category 1/c
Coil versions
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current Rights to change data / design reserved
Vdc Vdc Vdc Vdc c mA
054 6 3.9 0.45 13.2 100+10% 60.0
050 12 7.9 0.9 26.4 400+10% 30.0
046 24 15.8 1.8 53.0 1600+10% 15.0
043 48 31.6 3.6 106.0 6400+10% 7.5
042 60 39.5 4.5 132.0 10000+10% 3.7
All figures are given for coil without preenergization, at ambient temperature +20C
Edition: 07/2003
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 2000 Vrms
Clearance / creepage 8 / 8 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
Tracking resistance of relay base PTI 250
Faston Power Relay 410 83 3 mm
1 pole 16 A, 3 mm contact gap
S0256-CD
S0282-AB
Features
2 N/O contacts, 16 A
Fast-on connectors 6.3 x 0.8 mm
Contact gap > 3 mm
4 kV / 8 mm coil-contact
Applications
Power Supplies, domestic appliances, heating controls
V KSND
Contact data
Configuration 2 N/O contacts
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Max. breaking voltage DC 250 Vdc
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Peak inrush current 20 msw 25 A
Contact material AgCdO
Contact ratings
Type Load Operations
41501 / 04 16 A, 250 Vac, cosj=1 1x105
Coil data
Nominal voltage DC coil 12...220 Vdc
AC coil 24...380 Vdc
Nominal coil power DC coil 1.3 W
AC coil 2.8 VA
Operate category 1/b
All figures are given for coil without preenergization, at ambient temperature +20C
Other coil voltages on request
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 2000 Vrms
Clearance / creepage 8 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage B / 400, C / 250
Tracking resistance of relay base CTI 600 M
Other data
Flammability class according to UL 94 V-0 S0469-AA
S0469-AB
Edition: 10/2002
OUDHseries
10 Amp Miniature,
Sealed PC Board Relay
Appliances, HVAC, Office Machines.
16
Ordering Information
Typical Part Number B OUDH -SH -1 12 D M
1. Basic Series:
OUDH = Miniature, sealed PC board relay.
2. Enclosure:
SS = Vented (Flux-tight)* plastic cover.
SH = Sealed, plastic case.
3. Termination:
1 = 1 pole
4. Coil Voltage:
03 = 3VDC 09 = 9VDC 24 = 24VDC
06 = 6VDC 12 = 12VDC 48 = 48VDC
5. Coil Input:
D = Standard
6. Contact Arrangement:
Blank = 1 Form C, SPDT M = 1 Form A, SPST-NO
* Not suitable for immersion cleaning processes.
15.3 0.3
3.5 0.3
7.62 0.3
17.10 0.3 7.62 0.3
5.08 0.3
5.08 0.3
12.70 5.08
Reference Data
Coil Temperature Rise Operate Time Life Expectancy
60 12 100
50 10 28VDC Resistive
Temp. Rise (Deg.)
Operation (x 104)
40 8
Time (msec)
Operate Time
30 120VAC Resistive
6 10
20 4
10 2
Release Time
1
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 2 4 6 8 10 12
Coil Power (W) Coil Power (W) Contact Current (A)
17
Miniature Power PCB Relay T7N / T7N-WG
1pole 10A
Features
1C/O or 1N/O contact
Creepage/clearance to VDE 0435 and VDE 0700
Sensitive 360 mW coil available
Version T7N-WG with tracking resistance CTI 325
Applications
Domestic appliances, heating control, building control,
measurement&control
T7N: VUC
T7N-WG: V Z
F0189-B
Contact ratings
Type Load Operations
AgCdO 10 A, 240 Vac 100x103
AgCdO 5 A, 240 Vac, resistive 2x105
AgCdO 2 A, 120 Vac, cosj=0.5, 60 C 1.4x106
Coil versions
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Edition: 02/2003
Other data
Flammability class according to UL 94 V-0
Ambient temperature -40...+85 C
Mechanical life 10x106 operations
Max. switching rate at rated- / minimum load 30 min-1 / 300 min-1
Operate- / release time 10 / 5 ms
Bounce time N/O contact / N/C contact 0.6 / 17 ms
Vibration resistance >10 g
Shock resistance (function) >10 g
Shock resistance (destruction) >100 g
Category of protection (IEC 61810) RT III - wash tight
Relay weight 11 g S0260-AB
Dimensions
Dimensions in mm
S0260-AC
S0349-A
Edition: 02/2003
Edition: 02/2003
1pole 10A
Miniature Power PCB Relay T7N / T7N-WG
Features
Safety mains insulation
Contact gap > 3 mm
4 kV / 8 mm coil-contact
Ambient temperature up to 90C
Faston connectors (DIN 46244)
Snap or screw mounting
Applications
Industrial and domestic appliances, absolute safe power supply
disconnection
F0255-A
VZH
Technical data of approved types on request
Contact data
Configuration 2 N/O contact
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Contact material AgCdO, AgNi
Contact gap >3 mm
Contact ratings
Type Load Operations
DC-version 16 A, 250 Vac, resistive 2.5x105
DC-version 12 A, 250 Vac, resistive 2.5x105
AC-version 16 A, 250 Vac, resistive 1x105
AC-version 12 A, 250 Vac, resistive 1x105
Coil data
Nominal voltage DC coil 6...24 Vdc
AC coil 120...400 Vac
Nominal coil power DC coil 1.3 W
AC coil 2.0...2.5 VA
Operate category 2/c Rights to change data / design reserved
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 2000 Vrms
Clearance / creepage 8 / 8 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 380
Tracking resistance of relay base CTI 600M
Other data
Ambient temperature -20...+90 C
Mechanical life >2x106 operations
Max. switching rate at rated- / minimum load 15 min-1 / 600 min-1
Operate- / release time typ. 15 / 15 ms
Bounce time typ. 4 ms
Vibration resistance 2 g, 5...500 Hz
Shock resistance (destruction) 80 g
Category of protection (IEC 61810) RT I - dust protected
Relay weight 90 g
Packaging unit 42 pcs.
S0447-AA
S0447-AB
Features
Safety mains insulation
Fast-on connectors 6.3 x 0.8 mm
Contact gap > 3 mm
4 kV / 8 mm coil-contact
Snap or screw mounting
Applications
Industrial and domestic appliances, heating controls,
absolute safe power supply disconnection
F0259-AC
V SU
Contact data
Configuration 2 N/O contacts
Type of contact bifurcated contacts
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Rated voltage / max.breaking voltage DC 250 Vdc
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Contact material AgCu 3 / AgCdO
Contact ratings
Type Load Operations
419 DC-versions 16 A, 250 Vac, cos=1 5x105
419 AC-versions 16 A, 250 Vac, cos=1 2.5x105
419 DC-versions 12 A, 400 Vac, cos=1 2.5x105
419 DC-versions 20 A, 250 Vac, cos=1 6x103
Coil data
Nominal voltage DC coil 6...60 Vdc
AC coil 24...400 Vdc
Nominal coil power DC coil 0.72 W
AC coil 2.2 VA
Operate category DC colil 1/b
AC-coil 2/b
Edition: 11/2003
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 2000 Vrms
Clearance / creepage > 8 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
S0470-A
Insulation category / reference voltage B / 400, C / 250
Tracking resistance of relay base PTI 380 M
Other data
Flammability class according to UL 94 V-0
Ambient temperature -20...+85 C
Mechanical life DC-coil 2x106 operations
AC-coil 0.5x106 operations
Max. switching rate at rated- / minimum load 15 min-1 / 600 min-1
Operate- / release time typ. 15 / 12 ms
Bounce time typ. 8 ms
Vibration resistance 2 g, 5...500 Hz
Shock resistance (destruction) 80 g
Category of protection (IEC 61810) RT I dust protected
Relay weight 92 g
Packaging unit 50 pcs.
Features
1 C/O or 1 N/O contact
4 kV coil-contact
Vertical and horizontal version
Version with bifurcated contacts
Wash tight
Applications
I/O modules, heating control, timers
F0151-B VZ
Technical data of approved types on request
Contact data
Configuration 1 C/O contact or 1 N/O contact
Type of contact standard: single contact
Rated current 8 A / 5 A with AgNi 0.15
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Maximum breaking capacity AC 2000 VA
Make current (max. 4 s at duty cycle 10%) 15 A
Contact material AgCdO, AgNi 20, AgNi 0.15
Contact ratings
Type Load Operations
-A102 4 A, 30 Vdc, resistive 2x106
-A102 1 A, 24 Vdc, inductive L / R=40ms 2x105
-A402 1 A, 230 Vac, cosj=0.4 5x105
Coil data
Nominal voltage 6...60 Vdc
Nominal coil power 450...500 mW
Operate power 240 mW
Coil versions
Edition: 02/2003
Other data
Flammability class according to UL 94 V-0
Ambient temperature -40...+70 C S0257-AB
Mechanical life approx. 20x106 operations
Max. switching rate at rated- / minimum load 6 min-1 / 20 s-1
Operate- / release time 7 / 3 ms
Bounce time N/O contact/N/C contact 0.5 / 3 ms Horizontal version
Category of protection (IEC 61810) RT III - wash tight
Relay weight 14 g
Packaging unit 20 / 400 pcs.
Accessories see accessories E
Dimensions
Dimensions in mm
S0257-AE
1 pole 8 A
Power PCB Relay Card E
Features
1 C/O, 1 N/O or 1N/C contact
15 mm height
Ambient temperature up to 105C
4 kV / 8 mm coil-contact
Applications
General purpose power relay, timers, heating controls,
domestic appliances
F0247-A
VZ S H
Technical data of approved types on request
Contact data
Configuration 1 C/O, 1 N/O or 1 N/C contact
Type of contact single contact
Rated current 10 A 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Rated voltage / max.breaking voltage DC 250 Vdc
Maximum breaking capacity AC 2500 VA 4000 VA
Make current (max. 4 s at duty cycle 10%) 20 A
Contact material AgCdO, AgNi
Contact ratings
Type Load Operations
1 C/O 42900 16 A, 250 Vac, cos=1 3x104
1 N/O, N/C 42900 16 A, 250 Vac, cos=1 5x104
1 N/O 42900 10 A, 250 Vac, cos=1 3x105
1 C/O 42900 10 A, 400 Vac, cos=1 8x104
Coil data
Nominal voltage DC coil 3...60 Vdc
Nominal coil power DC coil 0.48 W (C/O), 0.42 W (N/O, N/C)
Operate category 1/b
S0421-AC
Other data
Flammability class according to UL 94 V-0
Ambient temperature DC-coil -20...+105 C
Mechanical life DC-coil 5x106 operations
Operate- / release time typ. 6 / 2 ms
Bounce time typ. 3 ms
Shock resistance (destruction) 100 g
Category of protection (IEC 61810) RT I dust protected
Relay weight 10 g
Packaging unit 50 / 400
Features
1 N/O contact
Sensitive coil 250 mW
5 kV / 10 mm coil-contact
Protection class II
Ambient temperature 105C at rated load
Height 15.7 mm
RoHS compliant (Directive 2002 / 95 / EC) as per
product date code 0413
Applications
Domestic appliances, heating control
VZ
F0178-C
Contact data
Configuration 1 N/O contact
Type of contact single contact
Rated current 10 A
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Maximum breaking capacity AC 2500 VA
Make current (max. 4 s at duty cycle 10%) 15 A
Contact material AgNi 90/10
Contact ratings
Type Load Operations
RTH84 12 A, 250 Vac, 105 C, dry switching >5x105
RTH84 10 A, 250 Vac, cyclical heat 105/40 C 2x105
RTH84 10 A, 250 Vac, 105 C 1.5x105
Coil data
Nominal voltage 5...60 Vdc Rights to change data / design reserved
Nominal coil power 250 mW
Operate category 2/b
Other data
RoHS - Directive 2002 / 95 / EC compliant as per product date code 0413 S0418-BT
S0163-BF
Dimensions
Dimensions in mm
S0272-AE
Features
1 N/O contact (W prerun contact + AgSnO2)
80 A / 20 ms inrush peak current
4 kV / 8 mm coil-contact, protection class II
Sensitive coil 480mW
Height 15,0 mm
Applications
Lighting systems, movement sensors, filament lamp loads, halogen
bulbs and motors
F0247-A
VZ
Technical data of approved types on request
Contact data
Configuration 1 N/O contact
Type of contact single contact
Rated current 10 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Make current (max. 4 s at duty cycle 10%) 16 A
peak inrush current (20 ms) 80 A
Contact material W (prerun contact) + AgSnO2
Contact ratings
Type Load Operations Standard
429 03 10 A, 250 Vac, resistive 5x104
429 03 2500 W, incandescent lamps 3x104
429 03 1300 W, fluorescent lamps, 140 F 3x104
429 03 1000 W, Dulux lamps, 140 F 3x104
Coil data
Nominal voltage 6...60 Vdc
Nominal coil power 480 mW
Operate category 1/b Rights to change data / design reserved
Coil versions
Edition: 07/2003
Insulation Dimensions
Dielectric strength coil-contacts 4000 Vrms Dimensions in mm
open contact circuit 1000 Vrms
Clearance / creepage 8 / 8 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
Tracking resistance of relay base PTI 250
S0421-AA
S0420-AF
Eigenschaften
1 Schlieer (Wolfram-Vorlaufkontakt + AgSnO2)
Einschaltspitzenstrom 80 A / 20 ms
4 kV / 8 mm Spule-Kontakt
Schutzklasse II
Sensitive Spule 480 mW
Geringe Bauhhe 15,0 mm
Anwendungen
Beleuchtungssysteme, Bewegungssensoren, Lampenlasten,
Halogenlampen und Motore
F0247-A
VZ
technische Daten der approbierten Typen auf Anfrage
Kontaktdaten
Kontaktanzahl und Art 1 Schlieer
Kontaktausfhrung Einfachkontakt
Nennstrom 10 A
Nennspannung / max. Schaltspannung AC 250 Va / 400 Va
Einschaltstrom (max. 4 s bei 10% ED) 16 A
Einschaltspitzenstrom (20 ms) 80 A
Kontaktwerkstoff W (Vorlaufkontakt) + AgSnO2
Kontaktlebensdauer
Type Last Schaltspiele Vorschrift
429 03 10 A, 250 Va, ohmsch 5x104
429 03 2500 W, Glhlampen 3x104
429 03 1300 W, Leuchtstoffrhren, 140 F 3x104
429 03 1000 W, Dulux Lampen, 140 F 3x104
Spulendaten
Nennspannung 6...60 Vd
Nennleistung 480 mW
Technische nderungen vorbehalten
Arbeitsbereich/Ansprechklasse 1/b
Spulenausfhrungen
Edition: 07/2003
Isolation Mabild
Spannungsfestigkeit Spule-Kontakte 4000 Veff Abmessungen in mm
offener Kontaktkreis 1000 Veff
Luft-/Kriechstrecke 8 / 8 mm
Isolation nach IEC 60664
Nennspannung 250 V
Verschmutzungsgrad 3
berspannungskategorie III
Isolation nach VDE 0110b (2/79)
Isolationsgruppe/Bezugsspannung C / 250
Kriechstromfestigkeit des Grundkrpers PTI 250
S0421-AA
S0420-AF
Features
1 N/O contact
80 A / 20 ms inrush peak current
15 mm height
4 kV / 8 mm coil-contact
Applications
House-control-systems, lighting systems, timer, sensors, valves,
motors
F0247-A
VU
Technical data of approved types on request
Contact data
Configuration 1 N/O contact
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Maximum breaking voltage DC 250 Vdc
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Peak inrush current (20 ms) 80 A
Contact material AgSnO2
Contact ratings
Type Load Operations Standard
42903..10.. 16 A, 250 Vac, cosj=1 2x104
42903..10.. 12 A, 250 Vac, cosj=1 5x104
42903..10.. 2500 W, Filament lamps 2x104
42903..10.. 800 W, Dulux lamps 1.5x104
42913..10.. 7.5 A, 250 Vac, cosj=0.75 2.5x104 TV-5
Coil data
Nominal voltage DC-coil 6...60 Vdc
Nominal coil power DC-colil 480 mW
Operate category 1/b
Relay weight 10 g
Packaging unit 50 / 400 pcs.
single pinning
Dimensions
Dimensions in mm
S0420-AS
S0421-AA
Features
1 N/O contact
Safety mains isolation
Contact gap > 3 mm
4 kV / 8 mm coil-contact, protection class II (VDE 0700)
PCB mounting or Faston connectors
Mounting brackets or snap mounting
Version with arc blow magnet for high DC-loads
Applications
Domestic appliances, industrial appliances, industrial controls
F0256-A
VZ C
Technical data of approved types on request
Contact data
Configuration 1 N/O contact
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Contact material AgCdO, AgCu3
Contact gap >3 mm
Contact ratings
Type Load Operations
430x5 16 A, 250 Vac, resistive, 70 C 1.5x105
430x5 10 A, 250 Vac, resistive, 105 C 1.5x105
Coil data
Nominal voltage DC coil 6...110 Vdc
AC coil 6...240 Vac
Nominal coil power DC coil 1W
AC coil 1.8 VA
Operate category 2/b Rights to change data / design reserved
S0448-AE
Other data
Ambient temperature -20...+70 C
Mechanical life >2.5x105 operations
Max. switching rate at rated- / minimum load 15 min-1 / 300 min-1
Operate- / release time typ. 15 / 8 ms
Bounce time typ. 4 ms
Shock resistance (destruction) 100 g
Category of protection (IEC 61810) RT I - dust protected
Relay weight 32 g
Packaging unit 50 pcs. S0448-AF
S0449-AB
S0449-AH
Power Relay 430 3 mm
1 pole 16 A, DC- and AC-coil
S0449-AK
S0449-AD
Eigenschaften
1 Schlieer
Sichere Netztrennung
Kontaktabstand > 3 mm
4 kV / 8 mm Spule-Kontakt, Schutzklasse II (VDE 0700)
Print- oder Fastonanschlsse
Haltebgel, Schnapp- oder DIN-Schienenmontage
Version mit Blasmagnet fr hohe Gleichstromlasten
Anwendungen
Haushaltsgerte, Industriegerte, Industriesteuerungen
F0256-A
VZC
technische Daten der approbierten Typen auf Anfrage
Kontaktdaten
Kontaktanzahl und Art 1 Schlieer
Kontaktausfhrung Einfachkontakt
Nennstrom 16 A
Nennspannung / max. Schaltspannung AC 250 Va / 400 Va
Max. Schaltleistung AC 4000 VA
Einschaltstrom (max. 4 s bei 10% ED) 25 A
Kontaktwerkstoff AgCdO, AgCu3
Kontaktabstand >3 mm
Kontaktlebensdauer
Type Last Schaltspiele
430x5 16 A, 250 Va, ohmsch, 70 C 1,5x105
430x5 10 A, 250 Va, ohmsch, 105 C 1,5x105
Spulendaten
Nennspannung DC-Spule 6...110 Vd
AC-Spule 6...240 Va
Nennleistung DC-Spule 1W
AC-Spule 1,8 VA
Arbeitsbereich/Ansprechklasse 2/b Technische nderungen vorbehalten
Spulenausfhrungen, DC Spule
Spulen- Nenn- Ansprech- Rckfall- Maximal- Spulen- Spulen-
code spannung spannung spannung spannung widerstand strom
Vd Vd Vd Vd c mA
Edition: 07/2003
Isolation Printbild/Schaltbild
Spannungsfestigkeit Spule-Kontakte 4000 Veff Ansicht auf die Anschlsse
offener Kontaktkreis 2000 Veff Abmessungen in mm
Luft-/Kriechstrecke 8 / 8 mm
Isolation nach IEC 60664
Nennspannung 250 V
Verschmutzungsgrad 3
berspannungskategorie III
Isolation nach VDE 0110b (2/79)
Isolationsgruppe/Bezugsspannung C / 250
Kriechstromfestigkeit des Grundkrpers PTI 380H
S0448-AE
Sonstige Daten
Umgebungstemperatur -20...+70 C
mechanische Lebensdauer >2,5x105 Schaltspiele
max. Schalthufigkeit mit/ohne Last 15 min-1 / 300 min-1
Ansprech-/Rckfallzeit typ. 15 / 8 ms
Prellzeit typ. 4 ms
Schockfestigkeit Beschdigung 100 g
Schutzart (IEC 61810) RT I - staubgeschtzt
Relaisgewicht 32 g
Verpackungseinheit 50 Stk. S0448-AF
Mabild Schnappbefestigung
Abmessungen in mm
S0449-AB
Technische nderungen
Edition: 07/2003
S0449-AH
Leistungsrelais 430 3 mm
1polig 16 A, Gleich- und Wechselspannungsspule
S0449-AK
S0449-AD
Features
1 or 2 pole in N/O, C/O and N/C versions
4 kV / 8 mm coil-contact
PCB mounting or Faston connectors
Mounting brackets or snap mounting
Applications
Motors, electro valves
F0257-A
VZ CS
Technical data of approved types on request
Contact ratings
Type Load Operations
1 pole 16 A, 250 Vac, resistive 2.5x105
2 pole 10 A, 250 Vac, resistive 2.5x105
Coil data
Nominal voltage DC coil 6...110 Vdc
AC coil 6...240 Vac
Nominal coil power DC coil 1W
AC coil 1.8 VA
Operate category 2/b Rights to change data / design reserved
Other data
Ambient temperature -20...+70 C
Mechanical life >2.5x105 operations S0448-AA
S0448-AC
S0448-AD
Dimensions
Dimensions in mm
Edition: 07/2003
S0449-AI
S0449-AA
Power Relay 430
1 pole 16 A or 2 pole 10 A, DC- and AC-coil
S0449-AK
S0449-AC S0449-AE