Sie sind auf Seite 1von 2

Irrigation Works Circle, Aligarh

Irrigation Division, Kasganj


O.K. Card
O.K. Card S.No.- 09 /Lot- 05 /Lining
Detail of work item for which O.K. card is required:- Laying of Cement concrete M20A20 using
paver machine in bed and side slopes of Parallel Lower Ganga Canal (PLGC).
Name of work:- Cement concrete lining using Paver Machine in Parallel Lower Ganga Canal
(PLGC).
Lot No.:- 05 Reach:- 36.300 KM to 45.600 KM
Name of firm:- M/S PATEL ENGINEERING LTD,
Patel Estate Road, Jogeshwari (W), Mumbai 400 102, India.

Agreement No.:- 03/ICB/SE/IWCA/2015-16, Dated:- 23.07.2015


Location for which O.K. card submitted:-PLGC from Km. _38.350_ to Km. _38.000_
S. Description Remarks of Remarks of
No. firm Department
J.E./A.E.
1 When O.K. card for Laying Cement Concrete M15A20 in sleepers
& under drainage filter arrangement in canal bed and side
slopes has been taken?
Compliance of O.K. card has been made during execution in all Yes Yes
respect.
2 Dewatering arrangements.
2.1 Type of dewatering arrangements done at site. Bore Well Point Yes
2.2 Size/ Number of dewatering pumps installed at site. 82 Hp/04 Yes
2.3 Installation is meterd or not? Metered Yes
2.4 Log book of installed pumps has been maintained/ Maintained Yes
issued by the department or not?
2.5 Continuous dewatering arrangement is available at site Available Yes
or not.
3 Layout of C.C. lining work.
3.1 Whether reference pillar has been made? Yes Yes
3.2 Whether arrangement for Centre line has been made at Yes Yes
site?
3.3 Smooth curvature alignment in curve reach & proper N/A N/A
center line alignment has been made?
4 Under drainage filter arrangement & concrete sleepers in
M15A20.
4.1 Whether Longitudinal/ Transverse drainage system has Yes Yes
been laid at proper R.L. & location required as per
approved drawing or not?
4.2 Whether concrete sleepers in M15A20 has been laid at Yes Yes
proper R.L. & location required as per approved
drawing or not?
5 5.1 Whether local Ganga sand has been laid at proper R.L. Yes Yes
& location required as per approved drawing or not?
6 L.D.P.E. film.
6.1 Whether 200 micron thick L.D.P.E. film has been laid Yes Yes
over the canal bed and side slopes with proper over
lapping and finishing.
6.2 Testing of L.D.P.E. film has been done or not? As Per MTC Yes
7 Testing of required material for M20A20 Cement Concrete Testing
for lining.(Yes/No.)
7.1 Cement (OPC-43 grade) Yes Yes
7.2 Coarse aggregate 10-20 mm size. Yes Yes
7.3 Coarse aggregate 4-10 mm size. Yes Yes
7.4 Coarse sand Yes Yes
8 Arrangements for concreting work.
8.1 Size of paver machine to be used. 15m*1 nos; Yes
13m*2 nos
8.2 Detail of batching plant available for use. 30 Cum/Hr Yes
8.3 Detail for No. & size of transit mixers available for 04Nos*6 Cum Yes
use.
8.4 Proper pouring arrangements made for concreting work Available Yes
at site.
8.5 Whether arrangement for submission of computerized Yes Done Yes
printout for each mix lot has been done at site or not?
8.6 Slump test apparatus is available or not? Available Yes
8.7 Moulds for casting of cubes are available or not? Available Yes
8.8 Which type of concrete curing arrangements has been By Tat Patti & Yes
planned or not? Ponding with
Water
Date of submission of O.K. card 21/02/2017

Note:- O.K. card should be issued after performing the relevant tests & Manufacturer Test
Certificates.

(Ankur Barsaiya)
Engineer QA/QC
Dated Signature with name &
Designationof firms representative
Name Signature
Reported by- S.P. Singh
J.E. incharge A.K. Singh
S.K. Gautam
Checked by-
1 Quality Control Engineer

O.K. given by Ashish Yadav


Assistant Engineer incharge

Das könnte Ihnen auch gefallen