Sie sind auf Seite 1von 3

1/9/2016 RaeSystemsRaeGuard2PIDFixedDetectorforVOCs|DigitalFixedGasDetectionSystems

| Login

DIGITAL SYSTEMS
Our Products > Gas Detection Instruments > Gas Detectors > Fixed Point Systems > Digital Systems

RaeGuard 2 PID Fixed Detector for VOCs


Manufacturer RaeSystemsInc

Brand RaeGuard2PID

Model FixedGasDetector

The RaeGuard 2 PID is a xed


photoionization detector (PID) that measures
a broad range of volatile organic compounds
(VOCs).

Click image to enlarge

The RaeGuard 2 PID by Rae Systems operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire single output, and
RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplied as the digital PID module can
be easily removed in hazardous locations for calibrations and maintenance.

The RaeGuard 2 PID has a graphic display and LED light status indicator for fault and alarm conditions. In addition, Low, High
and Fault relays can be congured to trigger external alarms or process controls. Over 200 correction factors are pre-
programmed and allow users to display readings of a specic target gas. A magnetic key interface enables the detector to be
calibrated and operational parameters adjusted with the explosion-proof enclosure in place.

Features
Class 1, Division 1 (Zone 1) continuous VOC monitoring solution for hazardous locations
Three wire 4-20 mA analog output and RS-0485 digital communication in ModBus protocol
Three dry contact relays (<30V, 2A) normally open (or normally closed), one for High and Low alarm, another for Fault alarm
Explosion proof stainless steel enclosure suitable for outdoor hazardous environment applications
Magnetic key interface eliminates the need to open the explosion proof housing when adjusting parameters
Continuous VOC monitoring in hazardous and non-hazardous area locations
Reduced maintenance costs due to easily removable sensor module. Sensor and lamp can be removed without tools and
serviced in hazardous locations
http://www.afcintl.com/raeguard2pidfixeddetectorforvocs.aspx 1/3
1/9/2016 RaeSystemsRaeGuard2PIDFixedDetectorforVOCs|DigitalFixedGasDetectionSystems

serviced in hazardous locations


Faster response time with sample ow through design powered by internal diaphragm pump
Humidity compensation ensures accurate readings even in humid environments

Specifications - DigiPID Sensor


PowerSupply 5V0.25VDC
Current 110mAmax
PowerConsumption <0.6W
MeasuringRange 0.01to100ppm0.1to1,000ppm1to1,000ppm
Resolution 10ppb,1ppmdependsuponmodel
ResponseTime PumpedT90:<30seconds
Calibration Twopointofflineandfieldcalibration,optionalthreepointcalibration
Accuracy 2%forcalibrationpoint
AnalogOutput 0.52.5(ro=1.0K)
DigitalInterface SerialInterface(UART)Transmit(Tx):3.3VTTLReceive(Rx):3.3VTTL
Warranty 2yearsforlamp,1yearforhousingandelectronics
OperatingTemperature 4Fto131F
Humidity 095%RHnoncondensing
EMI/RFI HighlyresistanttoEMI/RFI,compliantwithEMCDirective2004/108/EC
Package 316StainlessSteel,spraywatertightforIP65rating,dustmembraneforsensorfrontprotection
Size 1.02"x5.95"
Weight 19.4ounces

Specifications - Fixed Sensor Head


WorkingCurrent DC10to28V,210mAat24V
Power <5W
Output 420ma,threelevelprogrammablealarmrelays,RS485supportModbus
Sampling Internaldiaphragmpump,adjustableupto500cc/min
IPRating IP65
MechanicalInterface "NPTMale
Installation 2"pipeholdingorwallmounting
userInterface Threekeymagneticbaradjustment
Calibration TwoPoint
Warranty 1yearforpump,2yearsforhousingandelectronics
Material 3166stainlesssteel
OperatingTemperature 4Fto131F
Humidity 095%RHnoncondensing
Pressure 90to110kPa
Display 128x65matrixbacklitLCD,supportsgraphicdisplay
Size 10.1"x7.9"x4.2"
Weight 7.7pounds
ATEX:EXII2(1)GExd(iaGA_)IICT4GbUL/CSA:ClassI,DivI,GroupsA,B,C,D,T4pendingIECEx:Exd(iaGa)IICT4
Certifications
Gb

Ordering Information
The RaeGuard 2 PID can be ordered as individual components or as a complete VOC monitoring kit. The Sensor Head includes
an explosion proof ss enclosure with LCD display, integrated sampling pump and relays, digital connector for external sensors
and a magnetic key. The DigiPID Sensor Module includes a complete SS PID sensor module with UV lamp and digital connector
output for use with the RaeGuard 2, choice of detection ranges and a maintenance kit, The complete kit includes all of the
above. For pricing, please call AFC International at 1-800-952-3293, 219-987-6825 or fax 219-987-6826 or emailsales@afcintl.com
Description CatalogNo.
RaeGuard2PIDKit,0.01100ppmrange,ISapproved D030004000
RaeGuard2PIDKit,0.11,000ppmrange,ISapproved D030005000
RaeGuard2PIDKit,11,000ppmrange,Note:Correctionfactorsandrelaysarenotavailable,ISapproved D030008000
RaeGuard2PIDKit,0.01100ppmrange D030009000
RaeGuard2PIDKit,0.11,000ppmrange D030010000
RaeGuard2PID,11,000ppmrange,Note:Correctionfactorsandrelaysarenotavailable D030012000
RaeGuard2FixedHead,ISApproved D030007000
RaeGuard2FixedHead D030013000
DigiPidSensorModule,0.01100ppmrange,ISApproved C010001000
DigiPIDSensorModule,0.11,000ppmrange,ISapproved C010002000
DigiPIDSensorModule,11,000ppmrange,ISapproved C010004000
DigiPIDInternalDustFilter,pk/5 C012034005
DigiPIDExternalWaterTrapFilter,pk/5 4900011005
DigiPIDTeflonUVElectrodeShield,pk/10 C012017010
DigiPIDLamp,10.6eV1/2: 0500000003
http://www.afcintl.com/raeguard2pidfixeddetectorforvocs.aspx 2/3
1/9/2016 RaeSystemsRaeGuard2PIDFixedDetectorforVOCs|DigitalFixedGasDetectionSystems
DigiPIDLamp,10.6eV1/2: 0500000003
DigiPIDReplacementSensorKit C013007100
DigiPIDFlowthroughAdapter,SS C013012000

Downloads
RaeGuard2PIDliterature

Related Products

Rae Systems Series B14 - Gas


MiniRae 3000 Detection
Photo Ionization System
Detector (PID) Controller

Home | About Us | Repair | Resources | Blog | Contact Us | | Login

Contact:

Toll Free: 800-952-3293


Tel: 219-987-6825
Fax: 219-987-6826
sales@afcintl.com

Address:

715 SW Almond St, Ste C


DeMotte, IN 46310 USA
P.O. Box 894

Website maintained by Evolution Point, a Chicago Marketing Agency.

http://www.afcintl.com/raeguard2pidfixeddetectorforvocs.aspx 3/3

Das könnte Ihnen auch gefallen