Sie sind auf Seite 1von 4

Functional Magnetic

Resonance Imaging (fMRI)


Integration into everyday routine

www.usa.siemens.com/healthcare
Functional Magnetic Resonance
Imaging (fMRI)

The interest in functional magnetic which are described below, differ based processes such as learning, memory
resonance imaging has increased on the area of the brain being examined. and decision making.
considerably in the clinical environment
since new CPT reimbursement codes for Motor Tasks: The easiest paradigm 3. Processing:
pre-surgical planning were introduced to implement is a motor task. One After data collection, a statistical evaluation
in 2007. Siemens offers solutions that version of this paradigm is finger (t-test) is used to generate BOLD maps that
allow integration of fMRI techniques tapping where the patient is asked to are combined with routine 3D imaging
into the everyday routine. touch the thumb of one hand to each datasets such as MPRAGE. The combined
of the fingers during the activation data can then be used as a neuro-
A brief introduction of fMRI portion of the data collection. Motor navigational roadmap for use in pre-
Functional MRI utilizes the magnetic tasks are often implemented in pre- surgical planning or treatment assessment.
properties of blood to analyze brain surgical planning to assess the effects
activity in specific areas. The technique of lesions close to the motor strip and syngo fMRI
is based on small changes in blood to help improve the surgical outcome. Siemens syngo MR applications provide a
flow and is referred to as BOLD (Blood complete set of tools for fMRI workflow
Oxygen Level-Dependent) imaging. Auditory Tasks: These tasks can from data acquisition through post-
During this procedure, induced involve rhyming or word generation processing. The options available for
variations in the ratio of oxygenated to and may require the patient to speak Siemens portfolio of Tim (Total imaging
deoxygenated blood in localized areas specific words or phrases during the matrix) technology systems include:
of the brain are imaged to generate active portion of the exam. This
fMRI results (Figure A). paradigm allows the clinician to The syngo Neuro Suite (Standard)
visualize a lesion's proximity and This set of protocols (Figure B) and
The fMRI procedure effect on Brocas area, a key area of software is standard on all Tim systems.
There are three primary steps to an the brain associated with language, It includes techniques such as single-shot
fMRI procedure: preparation, speech and comprehension. epi as well as MPRAGE used to acquire
acquisition and processing. the anatomic information that will later
Visual paradigms: Visual paradigms be fused with the fMRI data.
1. Preparation: can be implemented when video
The patient is given a detailed projection systems are integrated Inline BOLD Imaging
explanation of the procedure and into the examination. This type of Inline Technology enables the automatic,
carefully instructed on the chosen paradigm can vary significantly but real-time calculation and display of
task in order to obtain the highest- normally requires the patient to focus statistical (t-value) images during the
quality exam with the least amount of on specific images or projections measurement of BOLD paradigms.
patient-induced motion. It is common during the examination. Examining Observing the data in real-time allows
to practice these tasks with the the visual cortex in this way provides the user to track the progress of the
patient before the exam to assure additional information that can assist examination and to assure patient
the best results. the surgeon with minimizing negative cooperation. Motion correction (MoCo)
surgical effects on vision when retroactively reduces the relative motion
2. Acquisition: removing lesions in this area. between the data sets measured.
The first step in the acquisition process Correction is performed through
is to collect routine 3D datasets. These Cognitive paradigms: Cognitive interpolation. It can be selected in
will later be used as the anatomical activation paradigms can be very advance or as post-processing. This
data upon which the fMRI information complex and can include stimuli to technique is also known as ART
will be mapped. Activity in specific examine areas of thought and (Advanced Retrospective Technique).
regions of the brain is induced and reasoning or even pain and fear.
controlled by a set of tasks called a These paradigms are normally The Inline Technology also enables users
paradigm. These tasks are performed confined to the realm of research but to stop examinations when an adequate
by the patient during the BOLD imaging offer a clinical benefit in understanding amount of signal has been generated,
measurements. Paradigms, some of the anatomic areas associated with saving time and improving workflow.

2
Figure A. Bilateral finger tapping Figure B. The syngo Neuro Suite (Standard). Figure C. syngo 3D Neuro Evaluation.
paradigm.

The included sequences and protocols


for fMRI acquisition (e.g. motor, visual)
need no adjustment and are ready for
immediate use. The "mosaic format" can
also be enabled to reduce storage space.
With Inline BOLD Imaging, functional
brain mapping can be optimally
integrated into the clinical routine, e.g.
prior to neurosurgical interventions.

syngo 3D PACE
Figure D. fMRI fused with fractional anisotrophy
3D PACE (Prospective Acquisition and MPRAGE.
CorrEction) enhances Inline BOLD imaging
with advanced motion correction during
the acquisition of a BOLD exam. In contrast
to a retrospective motion correction that All of these features can be implemented system to offer 3T field strength combined
corrects previously acquired data, the directly on the main console. This can with a 70cm bore and Tim (Total imaging
unique 3D PACE tracks the head of the help improve workflow by avoiding data matrix) technology. Figure D demonstrates
patient, correcting for motion in real time transfer to fMRI workstations typically an fMRI acquisition, taken from the Verio,
during the acquisition, improving the designed for research purposes. targeting the motor cortex using a finger-
accuracy of the data collection. tapping paradigm. The data is combined
Combinable with ART (mentioned above), Instructions to the patient in the form of with diffusion tensor imaging (DTI) and
3D PACE improves the accuracy of the a paradigm must be synchronized to the displayed on a 3D dataset to allow the
overlay of fMRI and anatomic data for a data acquisition. The simplest paradigms clinician to freely navigate through the
more precise fMRI study. utilize voice instructions over the patient results for evaluation or planning.
intercom. However, third party devices
syngo 3D Neuro Evaluation that deliver stimuli synchronized to Summary
syngo 3D Neuro Evaluation shown in the data acquisition are available to The introduction of CPT reimbursement
Figure C is the comprehensive processing improve the accuracy of stimulation codes has further fueled the interest in
and visualization package for BOLD fMRI. delivery especially for complex paradigms. functional magnetic resonance imaging
It provides a full set of features for Contact your local Siemens Sales in the clinical setting.
clinical fMRI such as statistical map representative to discuss the latest
generation, fused display of fMRI and DTI third party devices that can be used Siemens syngo MR applications help
results, color t-value maps on anatomical in conjunction with your system. meet the increased demand by offering
datasets, data export to neurosurgical a comprehensive set of sequences,
planning and much more. There are also fMRI with the MAGNETOM Verio protocols and processing tools, allowing
many advanced features for more fMRI benefits greatly from the increased fMRI to be easily integrated into the
research-oriented applications. signal-to-noise ratio of 3T systems. clinical setting.
Siemens MAGNETOM Verio is the first MRI

3
On account of certain regional limitations of Local Contact Information
sales rights and service availability, we cannot
guarantee that all products included in this Siemens Medical Solutions USA, Inc.
brochure are available through the Siemens Magnetic Resonance Division
sales organization worldwide. Availability and 51 Valley Stream Parkway
packaging may vary by country and is subject Malvern, PA 19355-1406
to change without prior notice. Some/all of the USA
features and products described herein may not Telephone: 1-888-826-9702
be available in the United States.

The information in this document contains


general technical descriptions of specifications Global Business Unit Address
and options as well as standard and optional
features which do not always have to be present Siemens AG, Medical Solutions
in individual cases. Henkestr. 127, D-91052 Erlangen
Germany
Siemens reserves the right to modify the design, Telephone: +49 9131 84-0
packaging, specifications and options described www.siemens.com/medical
herein without prior notice. Please contact your
local Siemens sales representative for the most
current information.

Note: Any technical data contained in this


document may vary within defined tolerances.
Original images always lose a certain amount
of detail when reproduced.

Global Siemens Headquarters Global Siemens Legal Manufacturer


Healthcare Headquarters
Siemens AG Siemens AG
Wittelsbacherplatz 2 Siemens AG Wittelsbacherplatz 2
D-80333 Munich Healthcare Sector 80333 Munich
Germany Henkestrasse 127 Germany
D-91052 Erlangen
Germany
Telephone: +49 9131 84-0
www.siemens.com/healthcare

www.usa.siemens.com/healthcare

Order No. A9119-8997-C1-4A00 | Printed in USA | 06.2008, Siemens AG