Mechanical Overview
TESi TRS
Mechanical Overview - Piston
TESi TRS
Low Compression
Mechanical Overview CCB Option
TESi TRS
CCB = Closed Circuit Breather
Mechanical Overview - Manifold
TESi TRS
Engine Specifications
A) Cogen specification both for natural gas and biogases for Combined
Heat and Power application
This specification is offered to manufacturers of Combined Heat and Power
(CHP/Cogeneration) plants,
B) Gas Electro-unit specification both for natural gas and biogases for
Power Generation applications
This specification is offered to manufacturers of radiator cooled generator sets both for
continuous and standby applications.
4006-23TRS1 / TRS2
ZPR
(zero pressure regulator)
Pandaros Governor
CAC
(charge air cooler)
Oil Cooler
Gas inlet
Auxiliaries panel
Control System Overview
In - line engines
Heinzmann Pandaros
Kronos K20 AFR Control (ZPR)
Detcon 20 Knock detection
Altronic DISN 800C Ignition
LKG01 Load sensor
Vee engines
Heinzmann Pandaros X2
Elektra AFR Control (no ZPR)
Detcon 20 Knock detection
Motortech MIC 500 Ignition Vee
LKG01 Load sensor
ZPR = Zero Pressure Regulator
Gas Solenoid Controls
Power supply
Pressure switches
4000 Series Knock Detection
Adjuster
under cap
Induction System
(MAS) Mixture
or Main Balance Line
Adjusting Screw
Gas Start-up panel components
Kilowatt Transducer
Kronos AFR
Control unit
Detcon20
Detonation sensing
module
4006 & 4008TRS Kronos 20
Kronos 20 AFR Control System
Perkins optimise
the Lambda map
of the engine to
give good
transient
capability below
50% load and a
linear NOx
response up to
100% load. These
maps are preset
and not
adjustable.
4006 & 4008TRS Kronos 20
4. Adjusting this Number up increases NOx reading and lowering reduces the NOx reading
5. Once adjustment is complete press enter then F6 to save the data to the Kronos controller
Objective
Prevent piston failure due to:
Detonation
Plug / lead failure
Air filter blockage
Overload running
Variable gas quality
Det-Con
Knock Detection system
Connection
Timing Level
reduction of
Knock
Running clearance
Timing disc
housing
Timing disc
Pick-up sensor
Altronic DISN Ignition Unit
Re-set magnet
Trigger magnets
4000 TRS Gas Engine
Heinzmann Governor
Ignition Unit
Pandaros overview
GOVERNOR STATUS
RUN STATUS
CAN COMMUNICATION
DC-
PANDAROS
- DESK DISPLAYS
PACKAGER DISPLAYS
GOVERNOR ERRORS
ACCESSORIES
Stop / run
Synchronising
Load sharing
Voltage matching
Reactive load share
Speed ramp
Load ramp
Laptop computer Soft load transfer
Isochronous ramp
Power factor set
Mains parallel
Island parallel
Actuator
Group synchronising
Digital power control
Magnetic pick-up
0,50 to 0,80mm
Pandaros Connecting to a PC
Changing the governor configuration
Active
error
Governor errors
Pandaros Digital Governor Overview
Elektra AFR Control System
Motortech MIC530 Ignition Controller
Motortech MIC530 Ignition Controller
If an over speed is recorded for any reason Switch of the power to the MIC500
To clear the fault.
Elektra AFR Control System
TRS Software Programs
Connection: 2
1. Connect communication lead between Pandaros or Kronos socket
2. Insert Heinzmann Dongle into laptop
3. On tool bar select start communication or press F5 key
You Must save the current file before attempting any changes
to the controller
Loading a Parameter file to the controller
1.
2
On tool bar select FILE
2. Select load parameter values and left click
5. Type the number into the left hand grey box and press enter
the parameter corresponding to the number will then be loaded onto
the graph
Adding further recording slots
1. Open the relevant folder in the case of the recording look in the following
C\program files dcdesk 2000\record sets\recorder_t.rec
1. 2000 Speed
2. 2300 Actpos
3. 2330ActPoSetpoint
Elektra Air Fuel Ratio minimum record sets: Kronos Air Fuel Ratio minimum record sets: