Beruflich Dokumente
Kultur Dokumente
Description
system of solutions for natural daylight, natural ventilation and smoke and
heat ventilation in the event of fire.
1.1.Integrity
1.2. Function
Natural daylight
Natural ventilation
Smoke and heat ventilation
1.3. Correspondence
up p er p a rt
op ening fra m e
2.1. Basement
Sizes:
Application 2
Lt G va lue U va lue Si
Types View
[%] [%] [W/ m.K] [db]
1 PMMA
1 83 73 5,4 17
opal
2 PMMA
2 69 53 2,7 24
c lea r/ o p a l
3 PMMA
3 63 45 1,7 28
c l/ c l/ o p a l
4 4 PMMA 55 41 1,3 31
So lid PC /
5 73 61 2,7 25
2PMMA
So lid PC /
6 67 52 1,8 28
3PMMA
2PMMA +
7 40 39 1,3 24
PC 16m m
Note: Triangular and circular shape of the thermo formed part are possible upon
request!
Application 3
Lt G va lue U va lue Si
Types View
[%] [%] [W/ m.K] [db]
1 PC 10m m 61 61 2,5 17
2 PC 16m m 54 55 2 18
3 PC 20m m 47 47 1,67 20
4 PC 25m m 40 42 1,3 22
5 PC 32m m 38 41 1,1 24
PC 16m m ,
6 64 50 1,31 21
NG
PC 25m m ,
7 67 42 1,1 18
NG
Lt G va lue U va lue Si
Types View
[%] [%] [W/ m.K] [db]
PC
1 52 52 2,2 - 2,0 21
10+ 4m m
PC
2 50 51 1,9 - 1,7 22
10+ 6m m
PC
3 44 44 1,7 - 1,0 27
16+ 4m m
PC
4 42 43 1,2 - 1,0 28
16+ 6m m
PC
5 38 40 1,1 - 0,9 32
16+ 10m m
PMMA /
6 69 53 2,7 24
PMMA
7 PC / PMMA 73 61 2,7 25
Gla ss
8 77 63 1,7 37
p a c ka g e
DK
9 0 0 1,2 - 0,65 24
4080m m
Wind deflector
Safety grid
Burglar grid
Insect and bird screen
Belt connectors
Sun protection elements inside/outside
Integration case
Ventilated board
Reliability Re 1000
Gas springs
Handle
Locking device
3.4. Technical parameters for Glos FF EXT GA
J 1200 EN 1873
im p a c t o f la rg e a nd sm a ll b o d y 2005 - FIRES-MP-024-12 AUNE
Air permeability
EN ISO12 207
Cla ss 2
Air p erm ea b ilit y