CONTENTS
KAREL reserves the right to make modifications in product features mentioned in this document for
development and improvement purposes, without prior notice. Individual products may possess
characteristics different from those mentioned in this document, according to their software and
hardware versions.
CAUTION
All the ground connections on the covers must be fixed and checked
before closing all the covers of the system.
Serious hazards may occur unless the conditions above are matched completely!
Attention!
For the proper operation of the system, please make sure that the following criteria are
satisfied.
Check the performance of the earth line connected to the system. If this line is not safe
enough, make a new and proper earth connection to the system to avoid possible hazards
that may occur due to the high voltages which may affect the system.
For the wall type systems, the rack holder metal part must be 100 cm above from the
floor level.
- Where the temperature is out of the range of 0 C to +45 C and the relative humidity
is above 80%,
- Close to Sulfuric gas producing areas like thermal springs, etc. that may damage the
system,
The frequent power cut-off may affect the performance of the system. Therefore, make
sure the system has an uninterrupted power source specific to the system.
Anything, which may prevent proper ventilation of the system may be risky and affect the
performance of the system.
Preface
The five chapters in this guide is prepared to supply detailed information for the people who
may need detailed technical information about the structure, installation and the
programming of the system. Thus, the methods to configure the system to meet the
customer requirements can be learned from this guide.
The first chapter Technical Reference Guide - gives detailed information about the
hardware and the software structure of the DS200 system. The information in this chapter
may require some background on mechanics, electric and electronics. The information flow
goes from the whole to the pieces forming up the whole. At the end a table of summary can
be found.
The second chapter Installation Guide explains the methods to configure the system in
a proper way and to meet all the customer requirements. Also the steps to run the system
and the items to be inspected at the first run time are explained in this chapter. This chapter
must be read carefully by the personnel who will make the installation of the system.
The third chapter Programming Guide explains the program codes, which are used to
define the working principles of the system. These codes are to be entered from the
telephone of the system supervisor. However, programming a big capacity system like DS200
from the telephone may be difficult. Therefore, after understanding the programming logic of
the system by reading this guide, the PC program ADMIN200 that is an affective tool to
program the system may be used for an easier programming.
The fourth chapter ADMIN200 Programming Guide explains how to setup and run the
ADMIN200 program on a PC and the way of using this software for programming different
parameters of the DS200 system.
The fifth chapter KNEE Programming Guide explains how to setup and run the KNEE
program on a PC and the way of using this software for programming the IP (Internet
Protocol) parameters of IP based modules of the DS200 system.
Best regards,
KAREL
TECHNICAL REFERENCE
GUIDE
The products may have some differences from the functionality written in this guide
according to the hardware revision or software version.
TABLE OF CONTENTS
SYSTEM CAPABILITIES .............................................................................................................. 1
SYSTEM ACCESSORIES.............................................................................................................. 4
I. SYSTEM DEFINITION ............................................................................................................... 6
I.1. FUNDAMENTAL HARDWARE STRUCTURE....................................................................................... 8
I.1.A. WALL-TYPE RACKS:......................................................................................................................................8
I.1.B. CABINET-TYPE RACKS ............................................................................................................................... 11
I.1.C. AUXILIARY PARTS FOR CABINET-TYPE FOURTH RACK ........................................................................... 13
I.1.D. CABINET ...................................................................................................................................................... 14
I.1.D.1. THREE-RACK CABINET: ......................................................................................................................................... 14
I.1.D.2. FOUR-RACK CABINET: ........................................................................................................................................... 16
I.2. BACKPLANES ................................................................................................................................... 17
I.2.A. BACKPLANE OF THE MAIN RACK BPL200-MAIN................................................................................... 17
I.2.B. BACKPLANE OF THE AUXILIARY RACK BPL200-AUX ............................................................................18
I.2.C. BACKPLANE OF THE POWER SUPPLIES BPL200-SPS........................................................................... 18
I.3. POWER SUPPLIES ............................................................................................................................ 19
I.3.A. AC/DC POWER SUPPLY - SPS200 .............................................................................................................. 19
I.3.B. DC/DC POWER SUPPLY- SPS248 ............................................................................................................... 22
I.4. CENTRAL PROCESSING MODULE - CPU200 & CPU CONNECTION CARD - DS200
CPUKON............................................................................................................................................. 23
I.4.A. CPU200 MODULE......................................................................................................................................... 23
I.4.B. REDUNDANT CPU200 MODULE ................................................................................................................. 25
I.4.C. DS200 CPUKON CARD: ............................................................................................................................... 26
I.4.C.1. EXTERNAL MUSIC CONNECTOR ............................................................................................................................ 27
I.4.C.2. EXTERNAL RELAY CONNECTOR ............................................................................................................................ 27
I.4.C.3. SERIAL DATA CONNECTORS.................................................................................................................................. 27
I.4.C.4. PC OR SERIAL PRINTER CONNECTORS (RS232)................................................................................................... 27
I.4.C.5. LAN ADAPTOR CARD .............................................................................................................................................. 28
I.4.C.6. RS485 CONNECTOR ................................................................................................................................................ 29
I.4.C.7. HR08 POWER FAILURE TRANSFER RELAY MODULE CONNECTOR ..................................................................... 29
I.5. UTILITY MODULE UTIL200 ............................................................................................................ 29
I.6. EXTENSION / LINE MODULES - EX200 ........................................................................................... 31
I.6.A. CONNECTION CARDS AND CABLES .......................................................................................................... 32
I.6.B. EX200 EXPANSION MODULES .................................................................................................................... 34
I.6.B.1. EX200 (0/16) ANALOG EXTENSION MODULE ......................................................................................................... 36
I.6.B.2. EX200 (0/16R) ANALOG EXTENSION MODULE ...................................................................................................... 36
I.6.B.3. EX200 (8/0) LINE MODULE...................................................................................................................................... 36
I.6.B.4. EX200 (8+8/0) EXTENDIBLE LINE MODULE ........................................................................................................... 37
I.6.B.5. EX200 (0/8S0) ISDN BRI EXTENSION MODULE...................................................................................................... 37
I.6.B.6. EX200 (1S2/0) ISDN PRI LINE MODULE ................................................................................................................. 37
1.6.B.7. EX200 (1R2/0) R2 DIGITAL LINE MODULE............................................................................................................. 38
1.6.B.8. EX200 (1VF/0) 1VF DIGITAL LINE MODULE ........................................................................................................... 38
1.6.B.9. EX200 (7CAS2B-RX/0) CAS2B ANALOG LINE MODULE ........................................................................................ 38
1.6.B.10. EX200 (8CAS2B-TX/0) CAS2B ANALOG LINE MODULE ...................................................................................... 39
1.6.B.11. EX200 (SS7 C) SS7 CONTROL MODULE............................................................................................................... 39
1.6.B.12. EX200 (SS7 L) SS7 LINK MODULE ....................................................................................................................... 39
I.6.B.13. EX200 (0/8U) DIGITAL EXTENSION MODULE ....................................................................................................... 39
1.6.B.14. EX200 (0/16U) DIGITAL EXTENSION MODULE .................................................................................................... 39
I.6.B.15. EX200 (8 T0/S0) ISDN BRI LINE/ EXTENSION MODULE ...................................................................................... 40
1.6.B.16. EX200 (0/8LB) LOCAL-BATTERY EXTENSION MODULE ..................................................................................... 40
I.6.B.17. EX200 (4 VOIP) VOICE OVER IP MODULE.............................................................................................................. 40
I.6.B.18. EX200 (4TWT) SPECIAL DUPLEX LINE MODULE ................................................................................................. 41
I.6.B.19. EX200 (4E&M/0) E&M LINE MODULE................................................................................................................... 41
I.6.B.20. EX200 (8E&M/0) E&M LINE MODULE................................................................................................................... 45
I.6.B.21. EX200 (ALARM) ALARM MODULE......................................................................................................................... 46
I.7. AUTO ATTENDANT AND VOICE MAIL MODULE EVM200L........................................................... 46
I.8. INTER-CABINET CONNECTION UNITS ........................................................................................... 48
I.8.A. CCU CARD.................................................................................................................................................... 48
I.8.B. CLOCK MASTER & CLOCK SLAVE CARDS ................................................................................................. 48
II. SOFTWARE ........................................................................................................................... 49
III. TECHNICAL SPECIFICATIONS ............................................................................................ 50
DS200 Technical Reference Guide
SYSTEM CAPABILITIES
Large-Capacity, Digital/Modular Telephone Branch Exchange
Maximum 672 Lines For Three-Rack, And 1344 Lines For Six-Rack Structures
Reliable And High-Quality Audio, Data And Video Transmission
224 Inner-Rack And 256 Inter-Rack Simultaneous Speech Channels
Busy Hour Traffic Of 10000 Calls/Hour
HARDWARE CHARACTERISTICS:
Distributed Microprocessor Structure That Provides Utmost Flexibility For A Digital
System
Open Architecture Design
Flexible And Hybrid Structure
DSP / ICP / SMPS Technologies
Cards That Have Been Manufactured Through The SMD Technology
General-Purpose Capacity Expansion Modules
Ex200 (0/16) Analog Extension Module
Ex200 (8/0) Analog Line Module
Ex200 (0/8S0) ISDN BRI Extension Module
Ex200 (1S2/0) ISDN PRI Line Module
Ex200 (1R2/0) R2 Digital Line Module
Ex200 (0/8U) Digital Extension Module
Ex200 (0/16U) Digital Extension Module
Ex200 (8 T0/S0) ISDN BRI Line/Extension Selective Module
Ex200 (0/8LB) Local Battery Extension Module
Ex200 (4E&M/0) E&M Line Module
EX200 (ALARM) Alarm Module
EVM200L Auto Attendant And Voice Mail Module
SOFTWARE CHARACTERISTICS
System-Embedded Self Testing/Troubleshooting Ability
VRTX Real-Time Operating System
The SDL Programming Language For The Main System Software And The C Language
For The Software Of Modules
Computer Aided Software Engineering (CASE)
Programmability Of The Exchange Locally Or Remotely
Programmability Over PC, Through A User Friendly Interface (ADMIN200) That Is Special
For The Exchange
1
DS200 Technical Reference Guide
PHYSICAL CHARACTERISTICS
Modular Structure With Slots For Easy Installation/Maintenance
Wall Or Cabinet Type Mounting Possibility
COMPATIBILITY CHARACTERISTICS
Configurable For Rural Applications
Configurable For Group EPABX Applications
Direct Use Of Fully Digital / ISDN Telephone Sets
Supports Connection Of Peripheral Devices Like Answering Machine, Wireless
Telephone, Facsimile And Modem
Euro-ISDN BRI / Euro-ISDN PRI Compatible
DDI / MSN Numbering
PP / PMP Configuration
1000 Different Telephone Numbers On PRI Lines
Possibility Of Configuring PRI Lines Both In TE And NT Modes
Opportunity To Take Advantage Of All ISDN Services
Interface Operating With The R2 Protocol That Contains 30 Digital Channels
Support For Videoconferencing And Fast Network Applications
Serial Computer / Serial Printer Output
Easy And Flexible Connection To Any Router
Support For Various Connections Among Exchanges
Interface For Local Battery Telephone Connection
Compatibility With Hotel Software
External Music Connection
Door Opener Activation
RELIABILITY CHARACTERISTICS
Power Supply Back Up For Uninterrupted Operation
Automatically Activated Redundant CPU Card For Uninterrupted Operation
Module Replacement Through Programming Without Shutting Down The System
Low Battery Power Cut-Off / Automatic Charging
Three-Level Extreme Voltage Protection
Possibility Of Transferring Exchange / User Parameters To Printer Over ADMIN200
Through Special Maintenance Programs,
- Transfer Of Data To A File, Which Is Related To Communication Between The CPU200
Communication Controller And Peripheral Devices
2
DS200 Technical Reference Guide
OPTIONAL CHARACTERISTICS
Power Back Up By Battery
Feature Of Conferencing With 16 Participants
Ability To Leave Message Between Extension-Extension / Line-Extension
Voice Mail Message Capacity Of Up To 1360 Minutes
Operation Capacity of 32 for recording / 32 for listening simultaneously
Informing Users About States Of Their Telephones By Voice Messages
Possibility Of Accessing GSM Lines Through A GSM External Line For Economical Calls
(By The GT02 Accessory)
Digital Wireless Telephone Compatible (By DT04 DECT Module Accessory)
Pager Compatible (By The PG100 Accessory)
Direct Connections Of Lines To Pre-Determined Extensions In Case Of Power Failure
(By The HR08 Accessory)
Extra Protection Against Thunderbolt, AM Interference And Leaking Signals From Power
Lines (By The FP04 And SP04 Accessories)
NET-CONSOLE That Provides Telephone-Computer Integration.
3
DS200 Technical Reference Guide
SYSTEM ACCESSORIES
FT20 Feature Telephone Set: The multi-functional telephone set, which is connected to
analog extensions over the special data line of the exchange, with the following features:
-LCD (Liquid Crystal Display) display with two or four-line options
-Smart display control keys
-16 LEDs (lights) in two colors with two functions
-Handsfree (Conversation without handset)
-Special output for earphone.
It is connected to the exchange by the four-wire KTS line.
ST20 Digital Feature Telephone Set: The multi-functional telephone set, which is
connected to digital extensions, with the following features:
-LCD (Liquid Crystal Display) display with two or four-line options
-Smart display control keys
-16 LEDs (lights) in two colors with two functions
-Handsfree (Conversation without handset)
-Special output for earphone.
It is connected to the exchange over a two-wire connection. It can be connected to the EX200
(0/8U) and EX200 (0/16U) Digital Extension modules.
Iris ISDN Feature Telephone Set: The multi-functional telephone set, which is connected
to ISDN extensions, with the following features:
-LCD (Liquid Crystal Display) display with two or four-line options
-Smart display control keys
-16 LEDs (lights) in two colors with two functions
-Handsfree (Conversation without handset)
-Special output for earphone.
It can be connected to the EX200 (0/8S0) ISDN BRI module.
DSS20 Direct Access Units: The fast access units that consist of programmable keys and
busy display panels, which can be used together with FT20 telephones.
LT200 (-H) Feature Telephone Set: The multi-functional telephone set, which is
connected to analog extensions over the special data line of the exchange, with the following
features:
-LCD (Liquid Crystal Display) display with two lines
-10 LEDs (with light) in single color with two functions
-Handsfree (Conversation without handset)
DSS200E Direct Access Unit: The fast access unit that consists of programmable keys and
busy display panels, which can be used together with LT200 telephones.
EVM200L Auto Attendant System and Voice Mail Box: The module that provides the
exchange with the features of automatic call distribution, the system messages and the
voice mail boxes.
4
DS200 Technical Reference Guide
5
DS200 Technical Reference Guide
I. SYSTEM DEFINITION
DS200 is a large-capacity telephone branch exchange, whose capacity can be expanded to
672 lines for three-rack, and 1344 lines for six-rack structures. Due to its distributed CPU
structure, it is a very reliable and flexible communication system, which is open to
development.
DS200 can be configured in two different mechanical structures, namely wall or cabinet
type: The wall-type DS200 can be configured in two structures: single-rack (with cover)
which can expand to maximum 224 lines, and two-rack (with cover) which can expand to
maximum 448 lines. On the other hand, the cabinet-type DS200 can be configured in the
following structures:
- Single-rack (maximum 224 lines),
- Two-rack (maximum 448 lines),
- Three-rack (maximum 672 lines),
- Four-rack (maximum 896 lines),
- Five-rack (maximum 1120 lines)
- Six-rack (maximum 1344 lines)
In this structure, the system can reach a capacity of six racks by the use of two cabinets.
The figures below illustrate general appearances of the wall-type DS200 system and the
cabinet:
Figure-1
6
DS200 Technical Reference Guide
Figure - 2
Racks constitute the basis of mechanical structure of DS200. There are two types of rack
structure within the body of DS200, namely Main Rack and Auxiliary Rack.
Both racks have 14 general-purpose slots for the same EX200 interfaces; however, the
CPU200 and DS200 CPUKON cards are situated only in the main rack. Therefore, there are
special slots for these cards in the main rack and these slots are not present in auxiliary
racks. As a result, backplanes of the main rack and auxiliary racks are different (BPL200-
MAIN and BPL200-AUX) and they cannot be used interchangeably.
Fourteen general-purpose slots are located in each rack of DS200 for the Expansion
Modules and EVM200L listed below. The modules that can be installed in these general-
purpose slots are:
7
DS200 Technical Reference Guide
8
DS200 Technical Reference Guide
BPL200-SPS Backplane
The CPU200 Central Processing Unit, the redundant CPU200 Central Processing
Unit (optional), the DS200 CPUCON CPU Connection Card and the DS200 CPU-FC
CPU Flat Cable
The UTIL200 Utility Card
The EX200 Expansion Modules (Maximum 14 modules)
The figures below show major mechanical and electronic parts of the main rack of the wall-
type DS200 exchange:
9
DS200 Technical Reference Guide
Covers
1a- Front Cover 1b- Top Cover 1c- Bottom Cover
1d- Back Cover 1e- Front Cover Bolts
Parts of a Rack
2a- Lower Front Part of the 2b- Upper Front Part of the 2c- Lower Back Part of the Rack
Rack Rack
2d- Upper Back Part of the 2e- Left Side Cover 2f- Right Side Cover
Rack
2g- Rack Partitioning Piece 2h- Protection Piece During 2i- Bottom Cover Support Piece
Shipment
Other
3- SPS Fixing Screws 4- Grounding Screw 5- Bottom / Top Cover Grounding Cables
6- Card Slot 7- Wall Mount Bar 8- Cable Guide
Figure 4
Auxiliary rack of the wall-type DS200 system is composed of the parts listed below:
RACK200 basic metal rack structure
10
DS200 Technical Reference Guide
11
DS200 Technical Reference Guide
Parts of a Rack
1a- Lower Front Part of the 1b- Upper Front Part of the 1c- Lower Back Part of the Rack
Rack Rack
1d- Upper Back Part of the 1e- Left Side Cover 1f- Right Side Cover
Rack
1g- Rack Partitioning Piece 1h- Protection piece during
shipment
Other
2- SPS Fixing Screws 3- Grounding Screw
Figure 6
In addition to those, there are some cables that are used for inter-rack connections, whose
details will be explained in later sections. These are:
BPL200-FC, connection cable between the BPL200-MAIN and BPL200-AUX
backplanes
BPLSPS-FC, connection cable among BPL200-SPS backplanes
12
DS200 Technical Reference Guide
CCU card
13
DS200 Technical Reference Guide
BPL200-FC
Figure 8
Related units shall be mentioned with these names in the remaining part of this
guide.
I.1.D. CABINET
Cabinet is a metal closet, which encloses racks in systems with two or more racks, which
facilitates mounting operation, which includes special compartments for batteries and
distribution frame (MDF), which is self-lit and ventilated by fan. It is manufactured in sizes
capable enough to contain three and four racks, in order to meet different capacity
demands.
14
DS200 Technical Reference Guide
15
DS200 Technical Reference Guide
16
DS200 Technical Reference Guide
I.2. BACKPLANES
BPL200-MAIN has been mounted between the upper and lower back parts in the metal rack.
The connectors on BPL200-MAIN completely fit the card slots in order to facilitate plugging
of modules.
Dimensions of the BPL200-MAIN backplane are 50 cm. x 14.8 cm and it weighs 0.4 kg.
17
DS200 Technical Reference Guide
BPL200- AUX has been mounted between the upper and lower back parts in the metal rack.
The connectors on BPL200- AUX completely fit the card slots in order to facilitate plugging
of modules.
Dimensions of the BPL200- AUX backplane are 46 cm. x 14.8 cm, and it weighs 0.4 kg.
18
DS200 Technical Reference Guide
backplane. On the other, that end has not been fixed to the backplane in the auxiliary rack; it
is connected to the card by a connector.
The connectors on BPL200-SPS have been shown together with their explanations in Figure
- 11 and Figure 12. List of those connectors have been repeated below for the sake of
completeness:
Cable connection point for BPL200-MAIN
A 10-pin male connector for BPL200-AUX connection
A 64-pin male connector for SPS248 connection
A 5-pin male connector for SPS200 connection
A 5-pin male connector (Inter-rack SPS Connector) at the upper left corner for the
upper rack BPL200-SPS connection
A 5-pin male connector at the lower left corner for the lower rack connection of
auxiliary racks and for the main rack connection of the HR08 Transfer Relay Unit
BPL200-SPS has been mounted between the upper and lower back parts in the metal rack.
The connectors on BPL200-SPS completely fit the module slots in order to facilitate
plugging of the SPS200 and SPS248 modules.
Dimensions of the BPL200-SPS backplane are 12 cm. x 9 cm., and it weighs 0.1 kg.
19
DS200 Technical Reference Guide
The SPS200 AC/DC Power Supply converts 230 V AC voltage to -56V DC, which is the input
value for the SPS 248 DC/DC Power Supply. SPS200 can also feed the system through
batteries and it can charge the batteries while being fed from the mains supply. In addition
to that, it protects the exchange against adverse factors that may affect through the electric
system.
Technical Information:
SPS200 operates with 230 VAC from the mains input. Its alternative current input has been
designed so as it is not affected by variations within the range +/- %10. There are two T-Type
2A / 250 VAC fuses in the main fuse compartment as the preliminary protection for the
phase and neuter lines.
The SPS200 AC/DC Power Supply has been connected to the 5-pin connector on the BPL200-
SPS Backplane (See Figure - 11) and it has been screwed to the upper front part of the rack.
(See Figure - 4 and Figure - 6). The SPS fixing screw must be loosened before the SPS
casing is removed from the exchange. It is not obligatory to use this screw after mounting,
which has been included to provide safety during transportation.
The SPS200 AC/DC Power Supply contains a metal casing to which the SPS200CR Power
Card is connected. The mains transformer is located on the SPS200CR Power Card.
SPS200CR, which gets 230 VAC over mains, generates 56 VDC, which is the input voltage of
SPS248. Pin assignments of the SPS200 connector on BPL200-SPS backplane are as
follows:
SPS200 BPL200-SPS Connector
Pin No Signal
1 - 54 VDC
2 ISOGND
3 -56 VDC
4 ISOGND
5 - VOUTREL
The DS200 system could be backed up with 48 VDC batteries in order to maintain operation
in case of power failures. Hence, there is the necessary battery back up circuitry on
SPS200CR. Since the system does not have embedded power failure transfer stations,
battery backup is essentially important for maintaining connection of the system to the outer
world. Considering the battery connection in this regard, use of dry-type batteries is strongly
recommended in order to maintain proper operation of the system. A battery connection of
48V/24 Ah is recommended for a full capacity, three-rack system with a traffic rate of 35 %
in average.
There is also an F-Type 8A/48VDC fuse on SPS200 for the battery input.
SPS200CR has the ability to charge the batteries even when the system power is on and the
system is operating with a low traffic rate. In addition to that, there is also a low current cut-
off circuit that turns itself off when the system voltage drops below 34 VDC, and which does
20
DS200 Technical Reference Guide
not turn on until the voltage goes above 46 VDC. Thanks to this circuit, SPS200 would
prolong life of the batteries by preventing their full discharge.
Operational Information:
Three LEDs that are on the front panel of the SPS200 Power Supply Module help figuring out
the power supply that is on use at that moment.
First of those is for 230 VAC (with the Mains Power tag), the second one is for 56 VDC
(with VOUT tag) and the third one is for fault detection (with Fault tag). When the system
is being fed from the mains supply during normal operation, the Mains Power and VOUT
LEDs light up. The Mains Power LED is turned off when there is no mains voltage. In that
case, if battery backup is on line, then the VOUT LED remains on. In the even that a
problem with the system power occurs, the FAULT LED lights up. In that case, the system
must be shut down.
In a multi-rack system, several SPS200 Modules are connected in parallel over inter-rack
SPS connections. Therefore, under normal conditions, i.e., if the system traffic load is not
extreme, one or two of the SPS200 modules operate, while the other(s) is (are) in standby
mode. LEDs of SPS200 that is in standby mode are off. Once SPS200 is in operation, its LEDs
begin lighting up.
There are also mains and battery On/Off switches on SPS200. In a wall-type system, one
could reach those switches even when the front cover is closed. (See Figure - 14).
Figure 14
Figure 15
The mains On/Off switch is supposed to be set to 1 position for normal operation.
Moreover, in order to put the battery on line in the systems with battery connection in case
of power failures, the battery switch is supposed to be set to 1 position. While the system
21
DS200 Technical Reference Guide
is being put on line, even in cases when battery connection exists, the mains switch is
supposed to be set to 1 and then the battery switch is supposed to be set to 1 after the
system starts to operate.
Dimensions of SPS200 are 8 cm. x 22.5 cm. x 20 cm. and it weighs 2.8 kg.
Figure 16
The SPS248 DC/DC Power Supply converts the -56 V output of the SPS200 AC/DC Power
Supply to the voltage levels of +5VDC, -5VDC and -48 VDC that are required for system
operation. Besides, there is a ring transformer on SPS248 for generating ring signal (67
Vrms.)
Technical Information:
22
DS200 Technical Reference Guide
The SPS248 DC/DC Power Supply is attached to the 64-pin power connector that is on the
BPL200-SPS backplane (See Figure-11 and Figure-12) and it is fixed to the upper front part
of the metal rack with a screw. (See Figure 4 and Figure 6).
The SPS248 DC/DC Power Supply contains a metal power rack onto which the SPS248CR
Power Card and the ring transformer are attached.
Outputs of SPS248CR and the ring transformer are transferred to the BPL200-SPS
backplane over the 64-pin power connector. The backplane carries these outputs to the
BPL200-MAIN/BPL200-AUX sections. Pin assignments of the SPS248 connector on the
BPL200-SPS backplane are as follows:
23
DS200 Technical Reference Guide
Figure 17
Technical Information:
The CPU200 module consists of two cards. One is the motherboard for carring the signals to
the bacplane and the other one is the one carring all the memory elements and the
microprocessor.
The CPU200 Module is connected to the related 64-pin connector on the BPL200-MAIN
backplane. (See Figure 11) and it is fixed to the upper and lower front sections of the metal
rack through the fixing latches that are on the front card cover.
CPU200 contains memory elements such as FLASH ROM, DRAM and EEPROM, as well as
ICP (Inner-rack Communication Protocol). In addition to that, CPU200 is responsible for
generation of system clock.
CPU200 generates address and data signals, which are necessary for the UTIL200 and
EX200 Modules. It transmits those signals to the BPL200-MAIN over a 64-pin connector, and
to the BPL200-AUX backplane over the two 34-pin connectors that provide the BPL200-MAIN
- BPL200-AUX connection, and to the second cabinet over a 34-pin connector, when
necessary.
Data signals necessary for the entire accessories are generated on CPU200 and then they
are transmitted to DS200 CPUKON over DS200 CPU-FC.
24
DS200 Technical Reference Guide
Figure 18
Operational Information:
A LED is situated on the front panel of CPU200. This LED continuously blinks during normal
operation. On the other hand, it remains on during a reset or parameter transfer. By this
way, status of the system can be monitored through this LED.
Dimensions of CPU200 are 20 cm. x 22.5 cm. and it weighs 0.3 kg.
25
DS200 Technical Reference Guide
Operational Information:
LED of the redundant CPU200 card continuously blinks, however its frequency is higher than
that of the LED used with the normal CPU200 card. By this way, one can know which of the
modules in the system is actively in use and which one stands by as redundant CPU200.
Dimensions of CPU200 are 20 cm. x 22.5 cm. and it weighs 0.3 kg.
26
DS200 Technical Reference Guide
Figure 19
27
DS200 Technical Reference Guide
9600 bps
1 stop bit
No parity
8 data bits
Pin-signal assignments of the RS232 connector on the DS200 CPUKON card are as in the
table below:
Pin Signal
2 TX (Transmitting)
3 RX (Receiving)
5 GND
28
DS200 Technical Reference Guide
Signals on the Ethernet port of the LAN adaptor card are as in the table below:
RJ45 pin no Signal
1 RX-1
2 RX-2
3 TX-1
6 TX-2
The UTIL200 Utility Module is an auxiliary processor card, which exists in every rack, and
that fulfills switching within its own rack, as well as among other racks, and that provides
for tone generation and receiving.
29
DS200 Technical Reference Guide
Figure 20
Technical Information:
UTIL200 can be placed in the card slot within the rack that has been specially designed for it.
(See Figure - 11, Figure - 12). The module is connected to the appropriate 64-pin connector
on BPL200-MAIN or BPL200-AUX and then it is fixed to the front lower and upper parts on
the metal rack through the fixing latches on front card cover.
There is a DSP module on UTIL200 that carries out the entire ton generation and receiving
actions. UTIL200 has TDM/PCM switching circuits that provide the entire inter-rack
switching. In addition to that, inner-rack switching is also carried out by the UTIL200 module
of each individual rack in coordination with CPU200 control.
In each UTIL200 module, there are 16 PCM channels for inter-rack switching and 14 for
inner-rack switching. By this way, a two-rack system operates totally without blocking.
Moreover, each UTIL200 module has 19 DTMF receivers in order to provide DTMF dialing
possibility for 19 extensions simultaneously.
The UTIL200 card also includes a special socket for the conferencing chip, which is optional
and that adds to the system the feature of conferencing with 16 participants. If the system is
desired to be enriched with the conferencing feature with 16 participants, then the
conferencing chip, which is provided by Karel, should be plugged in the appropriate socket
on the UTIL200 card that exists only in the main rack. A single conferencing chip must be
used even in multi-rack systems.
Below is the functional block diagram of UTIL200.
30
DS200 Technical Reference Guide
Figure 21
Operational Information:
There are two LEDs on the front panel of the UTIL200 module. The upper one signifies that
the card is operational and the lower one displays status of communication with the CPU.
During normal operation, while the first LED lights continuously, the other blinks.
Dimensions of UTIL200 are 20 cm. x 22.5 cm., and it weighs 0.3 kg.
31
DS200 Technical Reference Guide
EX200 (0/8U) 8 special digital extensions CON3 card and CBL-8 MDF cable
EX200 (0/16U) 16 special digital extensions CON2 card and CBL-16 MDF cable
EX200 (8T0/S0) 8 ISDN BRI (S0) line or extensions CON2 card and CBL-16 MDF cable
EX200 (0/8LB) 8 extensions with local battery CON3 card and CBL-8 MDF cable
EX200 (4VoIP) 4 VoIP channels An Ethernet cable with RJ45
connection
EX200 (4TWT) 4 TWT lines CON3 card and CBL-8 MDF cable
EX200 (8E&M/0) 8 E&M lines CON2 card and CBL-16 MDF cable
EX200 (4E&M/0) 4 E&M lines CON2 card and CBL-16 MDF cable
EX200 (ALARM) 4 Outputs / 28 Inputs 2 pieces CBL-16 MDF Cable
At its maximum capacity, a six-rack system has 1344 lines (extension + external line) in
6*14=84 interface modules.
The EX200 modules are installed in the general-purpose slots in the main or auxiliary racks.
(See Figure 11, Figure 12). In other words, the modules are connected to the appropriate
64-pin connector on the BPL200-MAIN or BPL200-AUX backplanes and then they are fixed to
the front lower and upper parts on the metal rack through the fixing latches on front card
cover.
DS200 has a factory default numbering plan starting from 1110 for extension and lines. After
all of the modules have been installed and the system has been powered, the system
automatically checks the entire modules and recognizes them and then it automatically
arranges the numbering plan accordingly.
There are 16 numbers that have been assigned to each slot in the numbering plan.
Therefore:
For instance, when an EX200 (8/0) module is installed in one of the slots, while the first 8
numbers are assigned to lines, the other 8 numbers remain as unused.
When an EX200 (4E&M/0) module is installed in one of the slots, while the first 4
numbers are assigned to E&M lines, the other 12 numbers remain as unused.
When an EX200 (1S2/0) module is installed in one of the slots, in addition to the entire 16
numbers in that slot, the first 14 numbers of the next slot are also assigned to the
channels of the ISDN PRI line. The last two numbers of the next slot remain as unused.
32
DS200 Technical Reference Guide
RJ45s that are at one end of the CBL-16 cable are attached to the corresponding female
connectors that are on the CON card. The cable lengths have been adjusted so as to
facilitate installation. The structure of the card and the cabling has been shown in the figure
below:
There are 2 RJ45 female connectors on the CON3 card. The 8-pair MDF cable, which is
named as CBL-8, has been designed specially for CON3. Male RJ45s at one end of the CBL-8
cable are attached to the corresponding female connectors on CON3. The cable lengths have
been adjusted to facilitate installation. The card and cable structures have been illustrated
below:
33
DS200 Technical Reference Guide
1&2. RJ45 Jack 3. Black cable tie 4. 2 x 8 cable, multi core, 0.45mm
Figure - 23
The CON2 and CON3 cards have been attached to the component side of the relevant
EX200B card. The two 20-pin connectors on the component-side of the CON2 and CON3
cards are attached to the corresponding connectors on the component side of the EX200B
card.
Operational Information:
There are two LEDs on the front part of the CON2 and CON3 cards. While the lower one
continuously lights to display that the card is operational, the upper one goes off whenever a
line on the card has been put in use; hence it signifies whether there is a busy line on the
card.
Dimensions of the CON2 / CON3 cards are 21 cm. x 5 cm., and they weigh 0.1 kg.
34
DS200 Technical Reference Guide
Technical Information:
Each EX200B card includes some circuitry such as PCM frame signal buffers,
microcontroller and ICC (Inner-rack Communication Controller).
Each EX200B card also has high current protection circuits against currents on itself. For
example: Since the analog extension module makes use of the 48 VDC, -5VDC and +5VDC
feeds of the system, there are three different high current protection circuits on it.
ICC is also an important piece of EX200B cards. Distributed CPU structure is maintained by
the Inner-rack Communication Protocol (ICP), which is an ISDN-like protocol. ICC is the
structure that actualizes communication between the main CPU of the system and the
modules.
There are 14 PCM for each rack (7 PCM for receiving, 7 PCM for transmitting - 32 frames for
each PCM.) Hence, each general-purpose slot uses 16 PCM frame pairs of a PCM channel
pair. These 16 PCM frame pairs have been connected to each slot on the backplane via
special paths so that a static structure has been formed.
Since there are 16 PCM frame pairs in each slot, each extension or line module can use at
most 16 PCM frame pairs in a single slot. As explained in section I.6.B, every other module
except the modules EX200 (1S2/0) and EX200 (1R2/0) make use of 16 PCM frame pairs;
therefore, they can be installed in any vacant slot. (Note that an extension should be
35
DS200 Technical Reference Guide
installed in the first slot, because the first number of the first expansion slot has been
assigned to the operator, through which programming will be done.)
Dimensions of DS200 EX200B are 20 cm. x 22.5 cm., and it weighs 0.3 kg.
Details about the entire EX200 Extension / Line Module types are as follows:
36
DS200 Technical Reference Guide
37
DS200 Technical Reference Guide
38
DS200 Technical Reference Guide
The connections to the EX200B (7CAS2B-RX/0) card are made over the CON2 line connection
card.
Since the EX200 (SS7 L) module can be connected to 30 separate channels, 16 PCM frames
in each slot are not sufficient. Therefore, the EX200B (SS7 L) card should be placed into an
even-numbered slot (the leftmost general-purpose slot has been numbered as 0,) and the
next odd-numbered slot should be left vacant, so that the EX200B (MFS/0) card can make
use of the 32 PCM frames in total, which belong to both slots.
39
DS200 Technical Reference Guide
In addition to the common circuits mentioned above, there are 16 identical special digital
extension interface circuits on the EX200B (0/16U) card.
Since the card has a digital protocol due to its structure, no extra circuit is needed; however,
each extension has a special digital driver.
Connections to the EX200B (0/16U) card are made over the CON2 line connection card.
40
DS200 Technical Reference Guide
In this type applications, usually Frame Relay or Leased Line type of lines are utilized for
data transfer among remote offices. Making phone calls as well, over these very lines would
provide advantage towards cutting communication expenses.
The EX200 (4VoIP) card works as a gateway that establishes connection between the
exchange and the IP network. Thanks to the EX200 (4VoIP) card, direct voice communication
can be established without the need for interfaces like FXO, FXS for routers present in the IP
networks.
Since the VoIP applications are software-based ones, the basic functions are fulfilled by the
DSP on the card.
Connections to the EX200B (4VoIP) card are made over the RJ45 Ethernet connection on the
front face of the card.
41
DS200 Technical Reference Guide
Figure - 25.a
Type 2
Figure - 25.b
Type 3
Figure - 25.c
Type 4
42
DS200 Technical Reference Guide
Figure - 25.d
Type 5
Figure - 25.e
* According to the position (See the illustrations above for each type.):
Upper PABX
Lower PABX
* According to the signaling:
Immediate Start
43
DS200 Technical Reference Guide
Wink Start
Inco
ming Call Signaling Scenario
Figure - 26.b
44
DS200 Technical Reference Guide
Delayed Start
* According to dialing:
DTMF
DP
* According to number of wires used for the speech channel:
2 wires
4 wires
Each E&M line can be connected with 4, 6 or 8 wires according to the selected configuration.
Therefore, cabling that was done over the CON2 card is arranged in order to fulfill need for
any configuration.
45
DS200 Technical Reference Guide
It supports R1 signalling feature, ANI detection and transmission features and CAS1B
signalling protocol.
The EX200 (8E&M/0) module supports the Type-1 and Type-5 connection types that have
been specified for the EX200 (4E&M/0) module and it provides two-wire speech channel
possibility.
Figure - 27
The alarm panel required a feed of 12 VDC. In order to provide the 12 VDC feed, a power
module is available to convert the 48 VDC output (battery connectors) of the system to 12
VDC.
46
DS200 Technical Reference Guide
47
DS200 Technical Reference Guide
4) Capacity for the system messages is 2 minutes (for the case when system messages are
announced in a single language),
5) Capacity for the voice mails is 1360 minutes.
Operational Information:
There are two LEDs on the front panel of the EVM200L module. While the lower one
continuously blinks to display that the card is operational, the other one goes off whenever
any voice channel is being used, so that it displays busyness status of the card.
External callers can make use of the opportunities offered by EVM200L only if they possess
DTMF telephone sets, because the ACD application would require the caller party to use
some of the keys. Results of that dialing action would reach the exchange as significant
signals only if the dialing method is DTMF.
Dimensions of EVM200L are 20 cm. x 22.5. cm. and it weighs 0.3 kg.
Dimensions of EVM-FL and EVM-DL are 6.5 cm. x 3.5 cm.
48
DS200 Technical Reference Guide
II. SOFTWARE
The DS200 system is a Stored Program Controlled one (SPC). In the system, there is a
microprocessor that controls the operation and there are FLASH ROM memory modules
that store the system software. The entire start-up system and line parameters are stored
in the FLASH ROM.
VRTX, the operating system, is a real-time one.
The software of the DS200 system has been designed so as to meet customer demands in a
wide range. There are three categories as the system software features are concerned:
1- User features,
2- Operator features,
3- Programs.
The user features are software facilities which any user can take advantage of through any
type of phone.
The operator features, on the other hand, are software facilities that can be used by the
system operator only. The operator, whose start-up access code is assigned as 1110 is the
first extension of the system.
Programs are the codes, which can be entered by the system supervisor only after the
system has been set to the programming mode. By default, the operator has been assigned
as the system supervisor. Several parameters that control the operation of the system can
be changed by programming.
ADMIN200 program, which is presented with the DS200 system as a standard, provides
control of the system through a PC by controlling the entire system parameters, as well as
making changes on them. In addition to that, the ADMIN200 program has superior features
that also provides for entering parameters that could not otherwise be entered through
telephones. Detailed information can be found in the guide of the ADMIN200 program.
Possibilities presented by the software have been explained in detail in the relevant guides.
49
DS200 Technical Reference Guide
50
DS200 Technical Reference Guide
CHARACTERISTICS
1. Analog Extension Interface Station Max 3000 Ohm
Loop Resistance
2. Extension Feed Voltages -48 VDC for analog extensions
-40VDC for ISDN/digital extensions
3. Max. Line Loop Resistance 2.2 Kohm
4. PRI ISDN / R2 Line Resistance 120 Ohm
5. Loop Start Line Interface DP and DTMF Signaling
12/16 KHz Pulse Price Signal Detection *
Polarity Reversal Detection
6. BRI ISDN Interface Euro-ISDN BRI compatible
7. PRI ISDN Interface Euro-ISDN PRI compatible
8. R2 Digital Interface DC Loop or Pulse type signaling
9. E&M Line Interface It supports type 1, 2, 3, 4 or 5. *
Signaling *:
- Immediate Start
- Wink Start
- Delayed Start
Number dialing method: DP or DTMF *
Speech channel: 2 wires or 4 wires *
ANI support with R1 signaling
10. Busy Hour Traffic 10000 calls / hour
11. Number Of Telephones That Can Ring 40 analog telephones / rack
Simultaneously
12. DP Dialing Make-Break Ratio 33 msec. make / 67 msec. break *
13. Wait Time between Two Consecutive 720 20 msec. for DP. *
Dials for Auto-dialer 175 5 msec. for DTMF. *
14. Cross-Talk Attenuation Better than 70 dB
15. Maximum Number of Telephone Sets 2 Telephone sets
per Extension
16. Ringer Voltage 67 Vrms, 25-30 Hz
17. Minimum Detectable Ringer Level 35 Vrms, 25-30 Hz
18. Environmental Conditions 0 C0 / +45 C0 temperature, 20% - 80% humidity
19. Hook Flash Duration 100-600 msec. *
20. Dimensions 70 cm. x 32 cm. x 28 cm. (for one rack)
78 cm. x 155 cm. x 60 cm. (for cabinet)
21. Weight 20 31 Kg (per rack)
115 175 Kg (per cabinet)
22. Maintenance Embedded Self Test / Solution
Local / Remote Programming
Programming over PC through the ADMIN200
program
* These parameters can be changed through programming.
51
DS200 Technical Reference Guide
CONNECTIONS
1. Connectors Line and extensions: RJ Type
External relay and external music: 623K4 Type
External unit interfaces: Pin type (2-pin, Tunik)
RS232 interface: D-Type (9-pin)
2. External Connections Standard Telephones: 2-wire
KAREL Feature Telephone Sets (LT200 (-H), FT200): 4-wire
KAREL DSS Modules (DSS200E, DSS200F): 2-wire
Karel Handsfree Digital Telephone (ST200): 2-wire
KAREL Local Pager (PG100): 2-wire
ISDN devices (Iris): 4-wire
PC / Serial printer: 3-wire
Alarm : 2-wire
DTMF TONES:
High Frequency Group (- 7 dBm)
1209 Hz 1336 Hz 1477 Hz
Low 697 Hz 1 2 3
Frequency 770 Hz 4 5 6
Group 852 Hz 7 8 9
(- 9 dBm) 941 Hz * 0 #
Nominal Frequencies of DS200 may deviate from the values above in the range 2.5 %.
52
INSTALLATION GUIDE
The products may have some differences from the functionality written in this guide
according to the hardware revision or software version.
TABLE OF CONTENTS
I.1.A. PREPARATION
The following requirements should be fulfilled prior to the installation of the exchange:
1- The wall on which the DS200 exchange will be mounted should be firm enough to carry
the weight and it should have a smooth surface.
2- The exchange should be installed in places that are not exposed to direct sunlight, that
are not humid, but that are ventilated, well lit, with an environmental temperature of 0-
45oC. It should not be exposed to effects of dust, vibration, oil and water.
3- Devices that generate high frequency waves (such as welding machines, office equipment
such as computers and telex machines, air conditioners, TV sets) should not be in the
same room if possible, and they should be at least 3 meters away from the exchange,
otherwise.
4- The mains supply should be reserved for the exchange only. The power supply of the
system should be uninterrupted and, if possible, the system should be powered from an
independent and well-grounded source from which no other device is powered.
* THE AIR VENTS AT THE TOP AND BOTTOM OF THE EXCHANGE MUST NOT BE
BLOCKED BY ANY MEANS. PREVENTING VENTILATION MAY DAMAGE THE
EXCHANGE!
I.1.B. APPLICATION
1- Plot a location that complies with the requirements indicated in the Preparation step
above.
1
DS200 Installation Guide
2- By making use of the installation template that comes with the racks, mark the locations
for the wall mount bars carefully that are to be used for hanging the racks on the wall.
The lower hole of the wall mount bars should be approximately 130 cm. above the floor. It
is essential to check whether the height of both holes are the same, in order to make
sure the exchange is parallel to the floor.
3- If there are two DS200 racks to be installed, then the lower hole of the wall mount bars,
for the first rack to be installed (That will be the lower rack.), should be 100 cm. above
the floor.
4- Drill the lower wall mount bar hole of the second rack 140 cm. above the floor, vertically
on the same line with the first one. When the installation is over, there will be a 10-cm
gap between the two racks.
Figure 1
5- Drive the anchor plugs into the holes, whose locations have already been checked, and
then screw the wall mount bars. Note that the right and the left side of the wall mount
bars differ. The screws must be fixed enough to burry their heads completely into the
wall.
6- After removing the front cover of the exchange by unscrewing the Allen screws, remove
the bottom cover by sliding it to the front.
7- While removing the bottom cover, watch out for the grounding cables that are between
the cover and the main frame, so that they will not break off. Remove the cables from the
covers together with their tags and keep them safe from any damage during the
installation.
2
DS200 Installation Guide
8- Slide the SPS200 to the front and remove it, after loosening its screws. (This is just for
facilitating the installation and not obligatory.)
9- Hold the exchange so that the wall mount bar holes at the back of the exchange
correspond to the wall mount bar holders, then push the exchange towards the wall, so
that the holders would carry it. Make sure the holders of both wall mount bars have been
inserted into the holes, and then lower the exchange cautiously. The exchange is fixed 5
mm. below. If it is still not fixed, even though it has been lowered for about one
centimeter, that indicates the holders do not carry it. In that case, try to hang the
exchange once again. In order to make sure that the exchange has been fixed, gently
shake it to check whether the wall mount bars really carry it.
10- In case it is necessary to displace the exchange, just lift it upwards cautiously and pull it
out.
3
DS200 Installation Guide
4
DS200 Installation Guide
I.1.C. GROUNDING
Grounding is required for protecting the DS200 exchange from lightning and other sources of
high voltage that may affect through lines or peripheral devices. The 230 VAC power cable of
the exchange has grounding feature, so there is no need for an extra grounding if the
electrical installation of the building has sound grounding.
Although special tools are required for measuring the sufficiency of grounding of the electric
installation of the building precisely, voltages between Neuter-Phase and Neuter-Ground
can be measured for getting a rough idea. The Neuter-Phase voltage should be 180-260 VAC
and the Neuter-Ground voltage should be 1-2 VAC. Those values must be consistent.
Possible voltage leakage in grounding installation may damage your exchange, just like all
other devices that require grounding.
5
DS200 Installation Guide
I.2.A. PREPARATION
The following requirements should be fulfilled prior to the installation of the exchange:
1- The DS200 exchange cabinet should be installed in places that are not exposed to direct
sunlight, that are not humid, but that are ventilated, well lit, with an environmental
temperature of 0-45oC.
2- It should not be exposed to the effects of dust, vibration, oil and water.
3- Devices that generate high frequency waves (such as welding machines, office equipment
such as computers and telex machines, air conditioners, TV sets) should not be in the
6
DS200 Installation Guide
same room if possible, and they should be at least 3 meters away from the exchange,
otherwise.
4- The mains supply should be reserved for the exchange only. The power supply of the
system should be uninterrupted and, if possible, the system should be powered from a
well-grounded source from which no other device is powered.
I.2.B. APPLICATION
1- Take the cabinet to a location as defined in the preparation step.
2- Lock the wheels by pressing the latches so that the exchange will not move.
3- Remove the front cover and the rack stopper screws that prevent the racks to slide.
Figure 4
4- Remove the back and side covers, after unlocking them, by lifting them for approximately
10 cm in a manner so that their paint is not scratched.
5- While removing the covers, watch out for the grounding cables that are between the main
frame and the covers so that they do not break off. Detach the cables, together with their
tags, from the covers and keep them so as to make sure they would not get damaged
during the placement of the exchange into the cabinet.
6- Push the main rack and auxiliary racks one by one until the holes of the removed
stopping screws appear. Then replace the stopping screws so that the racks would not
slide along the slots.
7
DS200 Installation Guide
Figure 5
7- Open the cable panels from rear in order to facilitate the access.
8- In order to connect the main rack and the auxiliary racks, as well as to make inter-rack
ground connection: First, use the BPL200-FC and BPLSPS-FC connection cables that
come with the auxiliary rack. There are three such cables. Two BPL200-FC's (34-pin flat
cable) are used for connecting the BPL200 backplanes and BPLSPS-FC (5-wire cable) is
used for connecting BPL200-SPS backplanes. In order to connect the backplanes:
a) Primarily, attach one end of each BPL200-FC to the BPL200-MAIN backplane of the
main rack that has been placed to the bottom.
b) Extend the free ends of the BPL200-FC cables to the second rack through the cable
holes corresponding to the upper panel at the back of the first rack and the lower
panel at the back of the second rack. Attach the ends of those two cables to the
BPL200-AUX backplane connector. The cables should be parallel to each other.
Repeat the same procedure to connect the second rack to the third, later. See Figure
2.
8
DS200 Installation Guide
9) Each rack comes as the power card-backplane connection has been made as factory
default. There are special cables that are used for this purpose. In case it is necessary,
those cables can be detached and the two cards can be separated or they can be
combined again, with those cables.
10) Then, you are supposed to make the power connection among the racks. In order to
connect the BPL200-SPS backplanes:
a) For the connection of the BPL200-SPS backplanes of the first and second racks, first
attach the BPLSPS-FC (5-wire cable) to the inter-rack SPS connector that is on the
BPL200-SPS backplane of the first rack.
b) Then, extend the free end of the cable through the holes of the metal plates that are
at the back of the first and the second racks and then attach it to the inter-rack SPS
connector that is on the BPL200-SPS backplane of the second rack. Repeat the same
procedure for the connection between the second and the third racks. See Figure 2.
11) Attach the 230 VAC cable to the connector on the SPS200. First, make sure that the on/off
switches are off and the fuses are free from any defect. Then, attach the other end of the
cable to one of the plugs next to the mains switch that is at the lower front section of the
cabinet, by extending it through the back of the cabinet.
Two 2A T-type fuses that are necessary for 230 VAC are in the drawer-type compartment
next to the 230 VAC input.
* VENTS OVER THE CABINET FANS MUST NOT BE COVERED BY ANY MEANS
DURING OPERATION OF THE SYSTEM. CERTAINLY CHECK WHETHER THE FANS
WORK PROPERLY, AT THE TEMPERATURES OVER 20C.
CAUTION!
The rules that must be obeyed strictly while powering the system on and off are stated as a
special chapter at the end of this guide.
When the system consists of three or more racks, if it is powered on and off by the battery
switches, then those switches are damaged in time, due to the electric arcs. In order to
prevent this situation, a delayed main battery breaker (10 Ampere 250 V Main breaker) is
included in the system. Control of the electricity provided to the racks from the battery is
maintained by this breaker. Detailed information about this is in Chapter II of this guide.
9
DS200 Installation Guide
The four-rack cabinet is used, if a system has four racks. In this case, since the entire racks
will fit into that cabinet, single-cabinet installation will suffice. The rack that will fit into the
uppermost rack slot of the cabinet will be of the main rack structure, too, like the first rack.
In two-cabinet systems, the first racks (lowermost) will be main rack and the others will be
auxiliary racks. However, there is CPU200 card only in a single cabinets main rack.
Likewise, there is DS200 CPUKON card in only a single main rack.
The first and the fourth racks are of the main rack structure and the connection between
these two racks is provided with some additional cards and cables. The list of those cards
and cables are below:
1) CC Extra card
2) Clock Master card
3) Clock Slave card
4) CCU card
5) Two BPL200-FC
6) Five PCM carrier cable
7) BPLSPS-FCX cable
In order to facilitate the connection of the two cabinets, you need to remove the SPS248
power units in the third rack of the first cabinet and the first rack of the second cabinet,
UTIL200, DS200 CPUKON and CPU200 cards (redundant CPU200, too, if there is any.), in the
first racks of both cabinets.
10
DS200 Installation Guide
11
DS200 Installation Guide
I.2.D. GROUNDING
Grounding is essential for protecting the DS200 Exchange from the effects of lightning or
other sources of high voltage that might affect over lines or peripheral devices.
12
DS200 Installation Guide
Although special tools are required for measuring the sufficiency of grounding of the electric
installation of the building precisely, voltages between Neuter-Phase and Neuter-Ground
can be measured for getting a rough idea.
The Neuter-Phase voltage should be 180-260 VAC and the Neuter-Ground voltage should be
1-2 VAC. Those values must be consistent. Possible voltage leakage in grounding installation
may damage your exchange, just like all other devices that require grounding.
Water installation of the building can be used for grounding, provided that the pipes are of
metal and no insulation material has been used at junctions. Indeed, the most secure
grounding method is inserting a copper rod that is 1.5 cm in diameter with 1.5 m of length, or
inserting a copper plate with 1 m2 of area to the ground and connecting it to the exchange
through a copper grounding cable. The cable should be fastened tightly to the rod or to the
plate and precautions should be taken against corrosion.
The cable coming from the grounding plate or grounding system must be connected to the
ground connection point of the exchange.
The DS200 Exchange and auxiliary racks are connected to each other tightly at the ground
connection points with the ground connection cable that comes with the shipped hardware.
13
DS200 Installation Guide
14
DS200 Installation Guide
15
DS200 Installation Guide
16
DS200 Installation Guide
attach them to the corresponding connectors on the DS200 CPUKON card. Then take the
free end of the cable out of the rack by extending it along underneath the rack through
the corresponding path within the cable channel that has been fixed on the back cover.
3- Install DS200 CPUKON card together with DS200 CPU-FC cable. First, attach the DS200
CPU-FC cable to the connector on the DS200 CPUKON card. Then, insert the DS200
CPUKON card so as its back corners fit the channel of the plastic card slot. Afterwards,
extend the free end of the DS200 CPU-FC cable along underneath the UTIL200 connector
on the backplane. As for the final step, when the card is completely placed, fix the DS200
CPUKON card by the fixing latches on the plastic card holder. See the figure below for
the correct usage of the plastic fixing latches.
Figure 10
4- In order to install the CPU200 module, place the back corners of the module into the
channel of the plastic card slot and push it towards the rack. Before you set the module
completely, connect the DS200 CPU-FC cable to CPU200. Then, push the CPU200 module
inside, so as it tightly fits on its corresponding connector on the BPL200-Backplane.
When the module has been completely set, fix it by using fixing latches on the front cover
of the card. (See The Technical Reference GuideFigure 24). See Figure 10 for the
correct usage of the plastic fixing latches.
In case it is necessary to take CPU200 out of the rack, press the card fixing latches on the
front cover of CPU200 toward the tag on the holder and then pull the module cautiously until
DS200 CPU-FC appears. As for the final step, detach DS200 CPU-FC from CPU200 and then
take it out of the rack.
In case it is necessary to take DS200 CPUKON out of the rack, press the card fixing latches
on the front cover of the card toward the tag on the holder and then pull the module
cautiously until DS200 CPU-FC appears. Afterwards, detach DS200 CPU-FC from DS200
CPUKON and take it out of the rack.
If a redundant CPU200 is needed in the system, then install that card in the special slot at the
right-hand side of CPU200, which is reserved for it by following the same installation steps
as for CPU200. Its connection to DS200 CPUKON card is provided by DS200 CPU-FC.
* DO NOT EVER REMOVE THE CPU200 CARD DURING THE OPERATION OF THE
EXCHANGE.
17
DS200 Installation Guide
card is facing out of the CPUKON card, attach the pins to the sockets. In addition to that, fix
the LAN Adaptor card to the CPUKON card through lead card holders.
In the figure below the LAN Adaptor card is illustrated as it has been attached onto CPUKON.
Figure 11
After you have attached the LAN Adaptor card onto the DS200 CPUKON card, adjust the
jumpers on the CPUKON card according to the proper configuration. The table below shows
states of the jumpers:
Jumper State Selected output
1, 2 ON
RS232
3, 4 OFF
1, 2 OFF
LAN Adaptor
3, 4 ON
After the installation of the card is over, make the network connection through a one-to-one
cable with RJ45 connectors on both sides.
18
DS200 Installation Guide
UTIL200 card of the first rack. While inserting the chip into the socket, make sure positioning
of the chip is correct.
In case there is an optional conference chip in the system, since this chip needs 32 PCM
channel in order to be functional, you must leave the last two general-purpose slots (The two
general-purpose slots on the rightmost edge of the rack) of the first rack vacant.
* WHILE INSERTING THE CONFERENCE CHIP INTO THE UTIL200 CARD, LEAVE
THE TWO GENERAL-PURPOSE SLOTS VACANT, WHICH ARE AT THE RIGHTMOST
SIDE ON THE BACKPLANE.
19
DS200 Installation Guide
20
DS200 Installation Guide
21
DS200 Installation Guide
Hold the module upright and make sure the corners in the rear fit lower and upper
plastic slot, then push it forward in the slot slowly and cautiously.
After more than half of the module has been inserted into the slot, arrange any
cable that is connected to the module.
You need to push a little bit harder so that the connector for backplane connection
fits, which is at the back of the expansion card.
Finally, push the module by gently pressing the latches upward / downward, which
are at the top and bottom of the card cover to fit it to its place.
Check if the card fixing clicks that are over the card cover latches have fit to the
holes on the chassis. Card latches that have not fit appear as in Figure 10.
Before the expansion module contacts with the backplane while it is being pushed into its
slot, the pins that are on and under the connection card provides grounding for the cards by
applying pressure on the ground contact spring. (See Figure 13).
In case it would be necessary to remove the modules following the first installation:
Pull the module by pressing the latches at the top and bottom of the card cover to
disconnect it from the backplane.
Pull the module until the line connection card gets out of the exchange. Be careful
about the cable that has been fixed under the exchange, so that it would not forced
too much by being pulled.
At this point, remove the line connection card from the expansion card and set it
free as connected to the line connection cable. Then do whatever would be
necessary by pulling the module out.
Repeat the steps above in reverse order in order to replace the card. While removing and
replacing the module, pay attention to the facts that line connection cable has been tightly
attached to the chassis, the expansion card and the connection cards are completely in
contact, and the card cover moves in a straight line parallel to slot.
22
DS200 Installation Guide
23
DS200 Installation Guide
24
DS200 Installation Guide
Pairs in the CBL-16 cable and connected extensions are given in the table below.
Pair No Color & Signal of Pair Extension No
1 White (R1) - Blue (T1)
1st ISDN Extension
2 White (T2) Orange (R2)
3 White (R1) Green (T1) 2nd ISDN
4 White (T2) Brown (R2) Extension
5 White (R1) Gray (T1)
3rd ISDN Extension
6 Red (T2) Blue (R2)
7 Red (R1) Orange (T1)
4th ISDN Extension
8 Red (T2) Green (R2)
9 Red (R1) Brown (T1)
5th ISDN Extension
10 Red (T2) Gray (R2)
11 Black (R1) Blue (T1)
6th ISDN Extension
12 Black (T2) Orange (R2)
13 Black (R1) Green (T1)
7th ISDN Extension
14 Black (T2) Brown (R2)
15 Black (R1) Gray (T1)
8th ISDN Extension
16 Yellow (T2) Blue (R2)
For the cable above, order of the four wires that are to be used for connection to ISDN
devices is important.
The signals represented as R are the receiving signals of DS200; on the other hand, the
signals represented as T are the transmitting signals. Pay attention to this order for
cabling.
Pin-signal assignments of cabling for the connection between DS200 and Iris ISDN
telephones are given in the table below:
Signal with RJ45 pins of the CBL-16 wires of Signal with respect
respect to Iris Iris side the DS200 side to DS200
T1 3 1 R1
R1 4 2 T1
R2 5 3 T2
T2 6 4 R2
25
DS200 Installation Guide
For the cable above, order of the four wires that are to be used for the ISDN connection is
important.
Pin assignments of the cable that comes with the EX200 (1S2/0) module are given with
respect to the RJ45 connectors at both ends, in the table below:
RJ45 Signal RJ45
1 R1 4
2 R2 5
4 T1 1
5 T2 2
26
DS200 Installation Guide
2 R2 5
4 T1 1
5 T2 2
An interface has been designed for the purpose of maintaining connection to the 1VF card on
the DS200 and the cards in the 1VF signalling system. That interface consists of eight EX200
(4E&M/0) cards and an EX200 (1S2/0) card that have been placed in a standard DS200 main
rack. The special software that is to run on the CPU200 card of that rack should have already
been installed. The EX200 (1S2/0) card should be installed in the first slot of the rack and the
EX200 (4E&M/0) cards in the next eight slots starting with the slot number 02. The 4 wires
coming from the 1VF lines are connected to the wires adjusted for four-wire speech that are
on the EX200 (4E&M/0) card. In the meantime, the EX200 (1S2/0) card is connected to the
EX200 (1VF) card by a one-to-one cable. Please refer to the corresponding section for the
wire-signal order of the EX200 (4E&M/0) card.
As for the table above, order of the 4 wires that are to be employed for the CAS2B connection
matters.
27
DS200 Installation Guide
As for the table above, order of the 4 wires that are to be employed for the CAS2B connection
matters.
28
DS200 Installation Guide
29
DS200 Installation Guide
Signal with respect RJ45 pins of the CBL-16 wires of Signal with respect
to NT1 NT1 side the DS200 side to DS200
T1 3 1 R1
R1 4 2 T1
R2 5 3 T2
T2 6 4 R2
30
DS200 Installation Guide
The pin-signal assignments that are necessary for the connection of the EX200 (4VoIP) card
are shown in the table below (the Ethernet standard):
Signal RJ45 Pin No
RX-1 1
RX-2 2
TX-1 3
TX-2 6
As for the cable above, order of the 4 wires that are to be employed for the Ethernet
connection matters.
31
DS200 Installation Guide
Connection orders of both signaling and voice transmission wires for cabling E&M lines are
important.
These wires should be connected by being crossed within their own groups.
Those orders are given in the table below for two correspondent exchanges:
32
DS200 Installation Guide
33
DS200 Installation Guide
Figure 14
34
DS200 Installation Guide
35
DS200 Installation Guide
SIGNALING SIDE
36
DS200 Installation Guide
37
DS200 Installation Guide
Type 5
LOWER and UPPER PBX
E&M channel 1: JP12, JP10, JP11 (pin 2-3) short circuit
E&M channel 2: JP15, JP13, JP14 (pin 2-3) short circuit
E&M channel 3: JP18, JP16, JP17 (pin 2-3) short circuit
E&M channel 4: JP21, JP19, JP20 (pin 2-3) short circuit
E&M channel 5: JP24, JP22, JP23 (pin 2-3) short circuit
E&M channel 6: JP27, JP25, JP26 (pin 2-3) short circuit
E&M channel 7: JP20, JP28, JP29 (pin 2-3) short circuit
E&M channel 8: JP33, JP31, JP32 (pin 2-3) short circuit
38
DS200 Installation Guide
Figure 15
The EVM-FL or EVM-DL cards can be installed in the slots reserved for them without respect
to any order.
After the installation of EVM-FL or EVM-DL is over, hold the module upright and make sure
the corners in the rear fit lower and upper plastic slot, then push it forward in the slot slowly
and cautiously. You need to push a little bit harder so that the connector for backplane
connection fits, which is at the back of the EVM200L card. In this final step, push the module
by gently pressing the latches upward / downward, which are at the top and bottom of the
card cover and make sure the module fits completely.
Check if the card fixing clicks that are over the card cover latches have fit to the holes on the
chassis. Card latch that has not fit appears as in Figure 10.
In case it would be necessary to remove the module following the first installation, pull the
module by pressing the latches at the top and bottom of the card cover to disconnect it from
the backplane. Then, pull it until it gets out of the exchange.
39
DS200 Installation Guide
connector at one end and with telephone connection box on the other, into one of the KTS
ports that are on the DS200 CPUKON card. Additionally, connect the first extension of the
first EX200 (0/16) card (blue-white pair) to the red and green ends of the connection box that
is at the other end of that cable.
Details about those connections have been explained in the guides of the related telephones
and in the ADMIN200 guide.
40
DS200 Installation Guide
After all the cards have been installed, the system is ready to be powered.
The methods for properly powering the system have been listed below for different system
configurations:
41
DS200 Installation Guide
5) Plug the mains cords of the entire SPS200 modules into the mains outlets that are on
the control panel of the cabinet.
6) Plug the mains cord that comes from the mains outlets on the control panel of the
cabinet into an outlet of the premise that has been properly grounded. Since the
primary mains switch is protected with a fuse of 10 A, the mains outlet of the premise
must be protected with a higher-rate fuse.
7) Connect the batteries (if battery connection is to be made) to the battery connection
points on the cabinet.
8) Make the connection from the primary battery switch to the first of the SPS200
battery connectors (Note that the battery connection is not made to the entire SPS200
modules.)
9) Turn on the entire mains switches on the SPS200 modules, beginning with the
SPS200 module in the first rack.
10) Turn on the battery switch that is on the SPS200 module to which the batteries have
been connected.
11) Turn on the primary mains switch that is on the control panel of the cabinet.
12) Turn on the primary battery switch that is on the control panel of the cabinet.
13) Turn on the two fan switches that are on the control panel of the cabinet. The fans
must be working while the system is in operation.
42
DS200 Installation Guide
12) Turn on the primary mains switch that is on the control panel of the first cabinet.
13) Turn on the primary battery switch that is on the control panel of the first cabinet.
14) Turn on the fan switches that are on the control panels of the cabinets. The fans must
be working while the system is in operation.
After being powered, the system carries out a series of automatic tests in order to check the
current configuration. Beginning with the card in the rightmost slot, two LEDs that are on the
front plastic panel of each card start to light in a row. This action begins with the bottom
rack.
After the entire LEDs have begun to light, the message connecting appears on LCD screen
of LT200 (-H) or FT20 feature telephone that is connected to the system. Once that message
disappears, the system is ready to operate.
* WARNING
1) In order to turn on and off a cabinet-type system, use the mains and battery
switches that are in front of the cabinet.
2) The correct way of powering the system is putting the batteries on line after
turning the system on.
3) The correct way of shutting down the system is putting the batteries off line
before turning the system off.
43
DS200 Installation Guide
Module LED
CPU200 It blinks.
Redundant CPU200 It blinks fast.
CC Enable It blinks.
UTIL200 It blinks.
44
DS200 Installation Guide
If you observe problems with LEDs of the CPU200, CC Enable, UTIL200 and SPS248 modules,
then shut down the system and replace the modules whose LEDs are off with new ones. Put
the system on line again, afterwards.
If the lower LED of any of the EX200 or EVM200L cards is off, then it is likely that there is a
problem with that card. In that case:
1) Cut the power to that card through the operator telephone by programming,
2) Replace the card with a new one,
3) Power the new card, again, through the operator telephone by programming.
The programming procedure for that purpose is as follows:
a) Dial 877777 through the operator telephone and wait for the dial tone,
b) Cut the power to the card by dialing 800950, then the slot number of the card and
finally 0. At that point, you are supposed to receive either the dial tone or the error
tone.
c) Remove the card from its slot by disconnecting it from the line connection card and
take it out of the system.
d) Place the new card into the slot by plugging the line connection card.
e) Power the card, again, through the operator telephone, by dialing 800950, then the
slot number of the card and finally 1.
NOTE: In order to power the card again, as explained above, a period of at least 30 seconds
must pass after the power is cut.
The table below illustrates card locations and slot numbers for a 6-rack system:
Sixth rack
94 80 81 82 83 84 85 86 87 88 89 90 91 92 93
SECOND CABINET
Fifth rack
78 64 65 66 67 68 69 70 71 72 73 74 75 76 77
Fourth rack
48 49 50 51 52 53 54 55 56 57 58 59 60 61 62
45
DS200 Installation Guide
Third rack
46 32 33 34 35 36 37 38 39 40 41 42 43 44 45
FIRST CABINET
Second rack
30 16 17 18 19 20 21 22 23 24 25 26 27 28 29
First rack
14 00 01 02 03 04 05 06 07 08 09 10 11 12 13
UTIL200 cards
EX200 or EVM200 cards
CPU200 card (no slot number)
CC Enable card (no slot number)
After the visual test and the necessary arrangements are completed, it would be useful to
check the system in general simply.
Choosing extensions from various racks randomly and then arranging phone calls among
them by establishing connections would be sufficient to test the fundamental structure of the
system. At this point, it becomes a necessity to have a good command of the numbering plan
of the system. Therefore, it would be wise to run the ADMIN200 program and review the
numbering plan through the Configuration window.
Once the ADMIN200 program runs and the Configuration window opens, numbers of the
lines on a card can be viewed as long as the mouse cursor is placed onto the related card
and the left mouse button is kept pressed.
When the system test is over, shut down the system, make the line connections over the
main distribution pane, complete the entire accessory connections and then put the system
on line again for use.
Afterwards, the related programming must be done preferably through the ADMIN200
program.
* WARNING
All the programmed parameters must be saved in the non-volatile memory of the
system and then they should be backed-up to a PC through ADMIN200.
46
DS200 Installation Guide
NOTE:
The following operations should be taken care of, not to face a dust contamination problem
that may cause a decrease in the performance of the DS200 system. Therefore it is
recommended that the following explanations are read carefully and applied.
Concerning the fan filter, which is used to protect the system from dust that may leak
through the air shutter under the DS200 cabinet the technical personnel should be careful
about these points:
The filter must be removed from its slot and cleaned every month, and changed every six
months. (These time periods may vary depending on the environmental conditions of the
installarion place.)
The covers of the system cabinet must always be closed.
The grids of the system air fans must not be closed with other materials.
The diameter of the holes on grids is a small value in accordance with EN60950 standard
so the grids may be filled with dust and blocked in time. So, the system supervisor should
check these grids, if it is necessary he should turn off the fans, remove the upper cover
and clean them with spraying air or using a hard bristle brush.
47
PROGRAMMING GUIDE
The products may have some differences from the functionality written in this guide
according to the hardware revision or software version.
TABLE OF CONTENTS
I. INTRODUCTION ........................................................................................................................................1
I.1. GENERAL DEFINITIONS ....................................................................................................................2
I.2. NUMBERING PLAN............................................................................................................................2
I.3. ABBREVIATIONS ................................................................................................................................2
II. PROGRAMMING MODE............................................................................................................................3
Entering The Programming Mode: ......................................................................................................3
Exiting The Programming Mode:.........................................................................................................3
Entering Program: ...............................................................................................................................3
III. GENERAL EXCHANGE PROGRAMS........................................................................................................4
Saving Program Parameters Into Memory: ........................................................................................4
System Supervisor: ..............................................................................................................................4
Initialization Of The System Tables: ....................................................................................................4
Automatic Night Mode: ........................................................................................................................5
Weekly Automatic Features:................................................................................................................6
External Music On Hold: ......................................................................................................................6
ACD Activation:.....................................................................................................................................7
PBX Group Parameters: ......................................................................................................................7
Ring Count For PBX Group Unanswered Calls: ..................................................................................8
Auto-Dialer Attempt Count:.................................................................................................................8
Ring-Back Tone To Be Heard During Calls Through ACD Lines: .......................................................9
Line Connection After A Call:...............................................................................................................9
ACD Extension:...................................................................................................................................10
CRL Filter Time:.................................................................................................................................10
Tone Detection Setting:......................................................................................................................10
GPBX Mode:........................................................................................................................................11
Tone During Waiting: .........................................................................................................................11
Call Record Status: ............................................................................................................................12
Call Recording Device:.......................................................................................................................12
Serial Printer Status: .........................................................................................................................13
Serial Printer Language: ...................................................................................................................13
Equal Loads On Lines: .......................................................................................................................13
Serial Printer Format: .......................................................................................................................14
Number Of Dialled Digits:..................................................................................................................14
Deactivating Number Of Dialled Digits:.............................................................................................15
ACD Response Time: .........................................................................................................................15
Call Recording In Network Mode:......................................................................................................15
Call Wait Duration: (Waiting Time Of Call In Park)............................................................................15
Relay-On Duration: ............................................................................................................................16
Duration For Automatic Hold:............................................................................................................16
Tone Duration To Drop Lines:............................................................................................................17
Line Call Restricted Prefix Table:......................................................................................................17
Permitted Line Call Prefix Table: ......................................................................................................18
Call Recording Type : (Defining The Local / STD / ISD Code For Call Recording)............................19
Erasing Prefixes:................................................................................................................................20
Phone Lock Level Definition: .............................................................................................................20
Forced Account Code User: ...............................................................................................................21
Deleting Forced Account Code User: ................................................................................................22
Deleting All Forced Account Code Users: .........................................................................................22
Forced Account Code User Status Query: .........................................................................................22
Query Of All Forced Account Users States:......................................................................................22
Account Code Use Permission: .........................................................................................................22
Local Pager Connection:....................................................................................................................23
EEPROM Table Reset:........................................................................................................................23
Analog Extension Hook Flash Duration:............................................................................................24
Signalization Parameters: .................................................................................................................24
Signalization Parameter Printout:.....................................................................................................25
DTMF Signal Parameters: .................................................................................................................25
Tone Cadence Detection Activation: ..................................................................................................26
Tone Cadence To Drop Lines: ............................................................................................................26
CRL Capacity Query: ..........................................................................................................................27
Group Parameters Query:..................................................................................................................27
IV. EXTENSION PROGRAMS ...................................................................................................................... 29
Intrusion Authority Level: ..................................................................................................................29
Line Access Authority Level:..............................................................................................................29
Extension Line Access Group : ..........................................................................................................30
Call Time-Out:....................................................................................................................................31
*, # Keys / Hook Flash Authority:................................................................................................32
Voice Mail Leave/ Lock Authority: .....................................................................................................33
Hotel Room Access Permission: .......................................................................................................33
Call Pick Up Authority:.......................................................................................................................34
Follow Me Authority: ..........................................................................................................................34
Call Back Authority: ...........................................................................................................................35
Access Authority From DISA Line To An External Line: ...................................................................35
Call Transfer Authority For Hot Line Users: .....................................................................................35
Incoming Call-Exempt Extension: .....................................................................................................36
Outgoing Call-Exempt Extension:......................................................................................................36
Automatic Password: .........................................................................................................................37
Call Record-Exempt Extension:.........................................................................................................37
Pager Code:........................................................................................................................................38
The Language Of The System Messages:..........................................................................................38
Voice Mail Warning: ...........................................................................................................................39
Date/Time Info With Voice Mail:.........................................................................................................39
Guest-Personnel / Fax Selection:......................................................................................................40
Hot Line: .............................................................................................................................................40
Direct-Call Hot Line : .........................................................................................................................41
Hotel Room Definition:.......................................................................................................................42
Local Extension:.................................................................................................................................43
Extension PBX Group: ........................................................................................................................44
Uniform Call Distribution Among Extensions: ..................................................................................45
Voice Mail Message Leave Authority: ................................................................................................45
Inaccessible Extension Through DISA / ACD Line: ...........................................................................46
Line Drop Exempt Extension: ............................................................................................................46
Busy Extension Signalling Exempt Extension: ..................................................................................47
Extended Secretary Group:................................................................................................................47
ACD Parameters: ...............................................................................................................................48
ISDN Fax Selection: ...........................................................................................................................49
Call Pick Up Group:............................................................................................................................49
PBX Group Parameters On Extension Basis: ....................................................................................50
PBX Group Parameters On PBX Group Basis: ..................................................................................51
Toll Account Query:............................................................................................................................52
Toll Account: ......................................................................................................................................52
V. LINE PROGRAMS................................................................................................................................... 54
Line Status & Signalling: ...................................................................................................................54
Line Parameters: ...............................................................................................................................54
Line Access Groups: ..........................................................................................................................55
Line PBX Group: .................................................................................................................................56
DISA / ACD Line Selection: ................................................................................................................57
Specific ACD Menus: ..........................................................................................................................58
DISA Parameters: ..............................................................................................................................59
Line-Line Connection Time-Out: .......................................................................................................59
Dialed Number Check / DISA E&M Connection Time-Out: ............................................................60
Line Pricing Information:...................................................................................................................61
Transmit/Receive Voice Level: ..........................................................................................................62
Dial Tone Check: ................................................................................................................................62
Equal Load On Line PBX Group: ........................................................................................................63
Call Record-Exempt Line: .................................................................................................................64
Signalling After Line Connection:......................................................................................................64
VI. PRI ISDN / R2 LINE PROGRAMS .......................................................................................................... 66
Ringing Extension: .............................................................................................................................66
Ringing Extension Deletion:...............................................................................................................67
ACD Menus:........................................................................................................................................67
DISA / ACD Line Selection: ................................................................................................................68
DISA Parameters: ..............................................................................................................................70
Line Number Root:.............................................................................................................................70
VII. BRI ISDN LINE PROGRAMS ................................................................................................................ 72
Ringing Extension: .............................................................................................................................72
Ringing Extension Deletion:...............................................................................................................72
ACD Menus:........................................................................................................................................72
DISA / ACD Line Selection: ................................................................................................................73
DISA Parameters: ..............................................................................................................................74
VIII. E&M LINE PROGRAMS....................................................................................................................... 76
Tone Reception / Transmission: ........................................................................................................76
Call Forwarding On E&M Lines: ........................................................................................................77
IX. EVM200 AUTO ATTENDANT & VOICE MAIL PROGRAMS ..................................................................... 78
EVM200 Card Programming Mode: ...................................................................................................79
Erasing All ACD Messages: ...............................................................................................................79
Erasing All System Messages: ..........................................................................................................80
ACD And System Message Recording: ..............................................................................................80
Listening To The ACD And System Messages: ..................................................................................85
Erasing The ACD And System Messages: .........................................................................................86
Copying Messages Among Cards: .....................................................................................................86
Copying All ACD Messages Among Cards:........................................................................................87
IX.1. GENERAL PARAMETERS ...............................................................................................................88
Constant ACD Messages:...................................................................................................................88
Total Penalty: .....................................................................................................................................89
Changing Language: ..........................................................................................................................90
Time-Out Durations: ..........................................................................................................................91
IX.2. THE MENU PARAMETERS AND THE ACTION TABLE ...................................................................92
Menu Entry Message: ........................................................................................................................93
Action Table: ......................................................................................................................................94
Menu Ringing Extension: ...................................................................................................................98
EVM200 Voice Level Settings: ............................................................................................................99
X. LAN ADAPTOR CARD PROGRAMS ...................................................................................................... 100
Network Settings: ............................................................................................................................100
XI. VOIP CARD PROGRAMS...................................................................................................................... 101
Network Settings .............................................................................................................................101
XII. LEAST COST ROUTING/NETWORKING PROGRAMS......................................................................... 102
LCR Activation:.................................................................................................................................102
LCR Route Access Authority:...........................................................................................................102
XIII. FLEXIBLE NUMBERING PROGRAMS............................................................................................... 104
Clearing Extension And Line Access Codes: ...................................................................................104
Clearing Feature Access Codes: .....................................................................................................104
Flexible Numbering Reset:..............................................................................................................104
Extension/Line Access Code:...........................................................................................................105
Changing Access Codes Of A Group Of Extensions Or Lines: .........................................................106
Feature Access Code: ......................................................................................................................106
Access Code According To The Physical Location: .........................................................................109
SUMMARY: .......................................................................................................................................109
XIV. MAINTENANCE PROGRAMS ............................................................................................................ 111
Stopping Alarm: ...............................................................................................................................111
Powering A Card On/Off:..................................................................................................................111
Clearing The Non-Volatile Memory: ................................................................................................112
Card Configuration:..........................................................................................................................113
Communication Query: ....................................................................................................................113
Dynamic Parameter Query: .............................................................................................................115
Card Version Query: .........................................................................................................................115
CC Version Query: ............................................................................................................................115
Analog and Rural Extension Card Version Query:...........................................................................115
ISDN BRI and Digital Extension Card Version Query: .....................................................................116
VoIP, TWT, PRI ISDN, BRI ISDN And R2 Line Card Version Query:.................................................116
Analog and LB Line Card Version Query: ........................................................................................116
Extension Parameter Query: ...........................................................................................................117
Version Query Of Karel Feature Phones And DSS Modules: ..........................................................117
Feature Table Query: .......................................................................................................................117
PRI ISDN Card As System Clock Source: ........................................................................................118
External Clock:.................................................................................................................................118
Line Monitoring: ...............................................................................................................................119
Resetting The System By Preserving Its Parameters:....................................................................119
XV. REMOTE PROGRAMMING ................................................................................................................. 121
Activation Of The Remote Programming :......................................................................................121
Important Notes For The Technicians Who Will Make Use Of The Remote Programming Feature:
..........................................................................................................................................................121
Exiting The Remote Programming Mode ........................................................................................122
DS200 Programming Guide
I. INTRODUCTION
Thanks to the rich software structure of the system, several parameters related to the
operation of the DS200 exchange can be modified according to customer requirements. The
modifications are done through program codes.
The system can be programmed in two ways. The first one is the programming through
telephone of the system supervisor (by default the first extension of the system, extension
1110). A different extension can be assigned through programming by the system supervisor.
The second way is using a PC to program the system. All of the programs that can be entered
through the system supervisors telephone can be entered through a PC by using the DS200
System Administrator software (ADMIN200) program, a method, which is much easier than
the program entrance through phone, thus it is recommended. In addition to that, some
parameters that can be modified through the ADMIN200 program cannot be modified
through programming with phone (eg. ring and tone cadence.) The details of this kind of
parameters can be found in ADMIN200 guide.
ADMIN200 program is given with the system as a standard tool. The details about the setup
and use of this program can be found its own guide.
The system cannot be programmed during normal operation mode. It should be switched to
programming mode by the System Supervisor. Following all the modifications of parameters
in programming mode, those modifications must be saved in the memory and then the
programming mode should be exited. Unless the modifications with the parameters are
saved, the parameters will have to be programmed again, in case of any power failure.
The structure of the program codes is standard. For all programs, there is a six-digit
program code, followed by parameter codes. Details about those parameters have been
included in the descriptions of the related programs. However, there is an important point
about extension and line access codes that should be emphasized: In several programs,
extension or line access codes must be entered as a parameter. One should be careful,
during the entry of the extension or line numbers while programming, of the fact that the line
numbers in the system are four digits by default but can be changed to any value up to 8
digits.
Additionally, the parameters of extensions or lines in groups can be modified through single
program code entrance, thanks to the group programming feature, which has been designed
for time saving for the programmer during the programming of extension or line
parameters. It is directly apparent from the program code whether or not the group
programming option exists. Codes of the programs with no group programming option begin
with the prefix 800. Codes of the programs with group programming option begin with the
prefix 801 and the group program codes begin with 802 prefix. That situation has been
indicated in the form of program codes within each program description.
In the following pages of this guide, the program codes related to various modules of the
DS200 system have been presented in the form of groups sorted with respect to program
code order. The purpose is making it easy for the programmer to find the programs for the
related module, as well as providing conceptual integrity.
It is recommended that all of the programs below should be read and all the codes to be
entered during the programming should be determined prior to programming.
1
DS200 Programming Guide
Definition: Brief explanation of the program is stated. This section is omitted in some
programs, since it has been included in the sections for necessary explanations and
parameter definitions.
Program Codes: Some extension and line parameters can be programmed by two alternative
ways. One of them is programming of a single line (extension or external line) and the other
is programming of line group. Thus, parameters related to an extension or line can be
programmed either one by one or in groups. In this section, both Singular Program Code
and Group Program Code are stated.
Parameters: Parameters related to programs are stated with their definitions. Some of the
parameters are conditional ones that are to be entered in connection with some previous
parameters. Those conditional parameters are indicated in braces: { }
Cancellation: The codes that will cancel the given program are defined here. Please note that
this section is used only when the related program has different activation and cancellation
codes.
Default value: Factory default initial values of program parameters are stated here.
Notes: Additional constraints, warnings and information about the program are stated.
While programming, in case an extension or line number is needed, the final value of that
number is used.
I.3. ABBREVIATIONS
In the table below, the meanings of the abbreviations used in this guide are given.
DP Dial Pulse
DTMF Dual Tone Multi Frequency
DISA Direct Inward Subscriber Access
ACD Automatic Call Distributor
ISDN Integrated Services Digital Network
PRI 30 - channel ISDN line (Primary Rate Interface)
BRI 2 - channel ISDN line (Basic Rate Interface)
E&M Ear & Mouth
2
DS200 Programming Guide
Notes
The phone through which the programming will be performed is the one with number 1110
that is connected to the first extension card in the first rack. This assignment can be changed
by programming. Upon the system is set into the programming mode, if there is a Karel
DSS200E module, which has been connected to the exchange, the Pr LED on the Busy
Display Panel is lit.
Entering Program:
While entering the program, its essentially important to enter parameters in correct length.
Otherwise, the program may be ineffective, or the system may not work as desired at all, due
to the erroneous entry.
Therefore, one should be careful about the length of parameters that have been indicated in
the program definitions. As can be seen in definition sections, lengths of some parameters
may be variable. If such parameters will be entered in a length that is shorter than the length
indicated as the maximum number of digits, then they must be terminated with the * key.
Because of that, the programming must be done with a DTMF phone. If the exchange has
previously been programmed, the extension, whose phone the programming has been
performed through, may not be authorized to use the key *. In spite of this fact, the key *
may be used while entering the programs. Internal dial tone is received upon proper
completion of the programming; otherwise, error tone is received. In such a case, the related
program code should be re-entered.
3
DS200 Programming Guide
Notes:
After programming has been completed, the program codes and all of the parameters must
be definitely saved into the non-volatile memory. Otherwise, recent values of the program
parameters will be lost in case of a blackout or any other power failure.
System Supervisor:
The system supervisor can be changed by the code below. The system supervisor sets the
system into programming mode, enters programming codes, saves them, and then exits the
programming mode.
800001 A
Parameters
A : The Extension access code
Default Value
A = 1110
Notes
The programming of the system can be done by the extension with the access code A only.
800002 P
Parameters
P : 1 Resets Line Parameters and the parameters of Line Status and
Signaling programs.
4
DS200 Programming Guide
: 8 Resets all system and user parameters, except the ones that belong
to common and private pool numbers.
: 9 Resets all system and user parameters and clears common and
private pool numbers.
Notes
You can make use of that feature, if you want to program your exchange completely or
partially.
In case of a failure, before using any of those codes, check whether the failure is persistent
or not by reloading the system parameters by 744. (The code 744 can be dialed by the
operator only.)
5
DS200 Programming Guide
Parameters
HHMMS : Automatic starting time of the Night Mode.
Cancellation
800003* should be dialed.
Default Value
The program with code 800003 is not active.
800004 S G N
Parameters
S : 0 Night feature
G : 0 Saturday
: 1 Sunday
: 2..6 Monday...Friday
Default Value
N = 0 for all days.
Notes
When the Automatic Night Mode Program is entered, the Weekly Night Mode program is not
deactivated at midnight; instead, it remains active until the termination time of the Automatic
Night Mode program.
800005 P
6
DS200 Programming Guide
Parameters
P : 0 External music is not active.
Default Value
P=0
Notes
You can let the lines you have put on hold listen to the music being broadcasted from an
external music source like tape player or radio, which is connected to your exchange.
ACD Activation:
It activates or deactivates the ACD feature.
800006 P
Parameters
P : 0 ACD is not active
: 1 ACD is active
Default Value
P=0
Notes
In order to activate the ACD, there must be at least one EVM200 card in the exchange.
Parameters
P : 0 When a line call request is not answered, call transfer to the PBX
group does not take place.
: 1 When a line call request is not answered, call transfer to the PBX
group takes place.
R : 0 When an internal call request is not answered, call transfer to the PBX
group does not take place.
: 1 When an internal call request is not answered, call transfer to the PBX
group takes place.
S : 0 If the call request is from the line and the extension is busy, call
transfer to the PBX group does not take place.
7
DS200 Programming Guide
: 1 If the call request is from the line and the extension is busy, call
transfer to the PBX group takes place.
Default Value
P=1, R=1, S=1, T=1.
Notes
All parameters defined by this program are valid for all groups defined by the Extension PBX
Group program.
That program defines the number of rings, after which a call request coming to a PBX group
is transferred to the next extension if it is not answered.
800008 P
Parameters
P : 1..8 Ring count
Default Value
P=3.
Notes
The parameter defined by this program is valid for all groups defined by the Extension PBX
Group program.
That program defines how many times a number will be called when the auto-dialer is
activated.
800009 P
Parameters
P : 01..16 Ring Count
Default value
P=15.
8
DS200 Programming Guide
Notes
The number defined by that program should not exceed any number prescribed by the
authorities in any country in which the exchange is used.
That program defines the structure of the ring cadence that will be heard during the ringing
of the called extension upon dialing a valid extension number by someone calling through
Auto Attendant or DISA line.
800010 P
Parameters
P : 1 The caller hears music.
Default Value
P=0.
Notes
Considering the possibility of normal ring-back tone confused with the standard CO
cadences, it will be useful to broadcast music instead of ring-back tone.
That program defines whether an extension will directly receive a dial tone after a
conversation is over.
800011 P
Parameters
P : 0 Dial tone connection.
Default Value
P=0.
Notes
1. When P = 1, the extension will receive error tone, instead of dial tone, upon termination of
a call. In that case, s/he is supposed to hang up and than lift the handset again, in order
to receive a dial tone.
9
DS200 Programming Guide
ACD Extension:
If an external automatic call distributor system is connected to the system, this program
defines the first extension that is psychically connected to this ACD.
800012 A
Parameters
A : The extension access code.
Notes
The extensions connected to ACD are put in the same PBX group and hence it is enough to
define only the first extension of the PBX group as the ACD extension.
This program determines the time for the system to start recording the external calls.
800013 P
Parameters
P : 0090 The system starts recording the call P seconds after the dialled
digits are set to the external line.
Default Value
P=10.
800014 P
Parameters
P : 0 801212-coded program works with default settings.
: 1 801212 code defines the duration during which dial tone is checked after 8
is dialed on external line.
Default Value
P=0
Notes
Some PSTN exchanges produce another dial tone between the first and second digits; if the
first dialed digit on the external line is 8. If P = 1 is activated, this tone is waited for at most
10
DS200 Programming Guide
the value defined by 801212 program. If dial tone is received within this period, the rest of the
number is sent to the external line. If dial tone is not received within this period, the line is
disconnected.
GPBX Mode:
It activates GPBX mode in which call charges of extensions and lines can be controlled on a
monthly basis.
800015 P
Parameters
P : 0 GPBX mode is not active.
Default Value
P=0
Notes
If the polarity is not reversed or a metering pulse is not received within the first minute, then
external calls are terminated in GPBX mode.
See 801199 coded Toll Account program for the details of call charge control of extensions
and lines.
800016 P
Parameters
P : 0 The extension receives silence as he is waiting for n seconds.
Default Value
P = 0.
Notes
This program is especially useful in case LCR is used for router connections. By P = 1, the
caller receives ring back tone while the router is reaching the called party, hence the caller
establish the call as a normal call.
11
DS200 Programming Guide
800020 P
Parameters
P : 0 No recording
: 4 Unanswered incoming calls and all outgoing line calls are recorded.
Default Value
P=3.
Notes
In call records, IC appears next to incoming calls and U appears next to unanswered calls.
800021 P
Parameters
P : 0 Call recording device is a computer.
Default Value
P = 0.
12
DS200 Programming Guide
Notes
In order to work with printer, the parameter 1 should be used. Moreover, according to the
printer type, the code 800022 0 is used for activating and 800022 1 is used for stopping the
printer.
After 800021 2 has been entered, the code 800022 0 must be entered again and the printer
must be set to on-line mode.
800022 P
Parameters
P : 0 The printer is set to on-line mode - activated.
Default Value
P = 1.
800023 P
Parameters
P : 0 The printout is in Turkish.
Default Value
P=0.
800024 P R
13
DS200 Programming Guide
Parameters
P : 00 P parameter is valid for all line access groups.
R : 0 Equal load on lines is not active. The system accesses the lowest
numbered line.
: 1 Equal load on lines is active. The least recently used line is accessed.
Default Value
P=00 & R =0
800025 P
Parameters
P : 0 Each call record is printed as two lines. A line can be at most
80 characters. The duration is printed in hh:mm format.
: 1 Each call record is printed in one line. The line can be at most
80 characters. The duration is printed in hh:mm format.
: 3 Each call record is printed in one line. The line can be at most
85 characters. The duration is printed in hh:mm:ss format.
Default Value
P=0
800026 P Q
Parameters
P : 09 First digit of the dialled number.
Default Value
For P=1 Q=3, for P=0 Q=11, for other digits Q=7.
14
DS200 Programming Guide
800027
800028 P
Parameters
P : 0 ACD answers the call immediately.
Default Value
P = 0.
800029 P
Parameters
P : 0 The calls established through these lines are not recorded.
Default Value
P = 1.
800030 T
Parameters
T : 03 .. 18 x 10 waiting duration in park in seconds
Default Value
T = 06
15
DS200 Programming Guide
Notes
When the waiting time is elapsed the call returns back to the parking extension.
Relay-On Duration:
That program defines the duration during which the relay systems, which can be used for
door opener controlling purpose in the system, are active.
800031 P T
Parameters
P : 0 First relay
: 1 Second relay
Default Value
T=00
800033 T
Parameters
T : 01..99 A call that is not answered after T seconds is put on hold
automatically.
Default Value
T = 00.
Notes
1- An incoming line call is answered automatically after T seconds if the operator is busy
and the external party hears music (If the Music On Hold has not been activated, the
caller receives wait tone.) The automatic hold feature has not been activated by default
at the beginning.
2- If the call on hold is not answered within 2.5 minutes, then the line is disconnected.
3- The external calls that are on hold are in the queue of the operator or the ringing
extension.
16
DS200 Programming Guide
800034 T P R
Parameters
T : 0 Tone detector is dedicated to the lines with 15 seconds intervals.
Default Value
T= 0, P=11 & R=5
Notes
1- Example: The tone to be received from a line is assumed as 300 msec ON, 300 msec OFF,
300 msec ON, 300 msec OFF, 900 msec ON, 300 msec OFF then;
Total tone duration = 300 + 300 + 300 + 300 + 900 + 300 = 2400 msec=2.4 sec
If P=11 & R=6 is set, then the system tries to detect a tone ON duration of 6 sec, within 11
seconds total tone duration.
2- When this program is used, one of the tone detectors of the system remains dedicated to
the lines used for line-line connection and this may affect the performance of the system
during high traffic. Therefore, if the cadence of the tone is known, it is recommended to
use 800087 coded program instead of this one.
800040 P T
Parameters
P : 1 Extensions with the local line call authority cannot call the numbers
starting with the defined prefix.
: 2 Extensions with the long distance line call authority cannot call the
numbers starting with the defined prefix.
17
DS200 Programming Guide
: 3 Extensions with the international line call authority cannot call the
numbers starting with the defined prefix.
: 4 Extensions whose authorities are for local line calls can call numbers
starting with 0212 and 0216.
Default Value
For P = 1, T = 0
For P = 2, T = 00
For P = 4, T = 0
Notes
1- Through that program, 8 numbers can be entered for each P value. Error ton is received
upon any further attempt afterwards.
2- If the number to be entered into the table consists of less than 4 digits, it should be
terminated with *. Besides, the program should also be terminated with * for each P
and T value that has been entered.
3- Levels 5,6,7 and 8 can be established by entering desired numbers. In that case, desired
extensions can be restricted to call numbers in desired regions by authorising through
the program 801101.
Example 1: 00 has been restricted for region 2 as default. In that case, when 800040 2
0212* is entered, both 00 and 0212 become restricted from now on.
Example 2: By entering 800040 5 435*, 801101 1111 6 5, only the extension 1111 is
restricted to call line numbers starting with 435. In that case, the extension 1111 can call
all local, long distance and international numbers except the determined number.
800041 P T
Parameters
P : 1 Extensions with the local line call authority can call the numbers
starting with the defined prefix.
: 2 Extensions with the long distance line call authority can call the
numbers starting with the defined prefix.
: 3 Extensions with the international line call authority can call the
numbers starting with the defined prefix.
18
DS200 Programming Guide
Default Value
For P = 4, T= 0212 and T = 0216
Notes
1- Through that program, 8 numbers can be entered for each P value. Error tone is received
upon any further attempt afterwards.
2- If the number to be entered into the table consists of less than 4 digits, it should be
terminated with *. Besides, the program should also be terminated with * for each P
and T value that has been entered.
Example 1: Extensions, with local line call authority, of an exchange that is in Asian side
of Istanbul, cannot normally call any number following an area code. Hence, they cannot
call the European side of Istanbul, either, since the area code is different. However, the
extensions with local call authority can be enabled to call numbers starting with 0212
(The area code of the European section) through the program 800041 1 0212.
800041 1 03 *
In that case, an extension with local line call authority can call long distance numbers
starting with 051 and 03.
Call Recording Type : (Defining The Local / STD / ISD Code For
Call Recording)
That program allows modification of local (L), long distance (STD), international (ISD) codes,
in order to define the types of calls that are to be listed during call recording.
800042 P T
Parameters
P : 1 Local line code
Default Value
The long distance code : 0
Notes
1- Through that program, 8 numbers can be entered for each P value. Error tone is received
upon any further attempt afterwards.
19
DS200 Programming Guide
2- The local, long distance and international codes defined by that program should be
entered into the corresponding fields of restricted prefixes table through the program
with the code 800040, for the appropriate operation of the exchange.
3- If the number to be entered into the table consists of less than 4 digits, it should be
terminated with *. Besides, the program should also be terminated with * for each P
and T value that has been entered.
800 042 2 0*
In that case, the long distance code becomes 0 and the international code becomes 09.
Erasing Prefixes:
The prefixes defined by Line Call Restricted Prefix Table and Line Call Permitted Prefix Table
or the L/STD/ISD codes can be erased through that program.
800043 P T
Parameters
P : 1 Restricted prefix table (800040)
Notes
If the parameter P is entered as 3, in that case:
Example: Upon entering 800043 1 2, the prefixes in the 2nd line of the restricted prefix table
are erased.
800044 P Q
20
DS200 Programming Guide
Parameters
P : 18 Lock level
Q : Locked prefix
Notes
1- At most 8 locked prefix can be defines for a level. Each of these locked prefix is defined
by separate entries of the program.
2- The locked prefix can be at most 4 digits. If the prefix is less than 4 digits, the code must
be ended by *.
800044 2 03 *
In that case, if an extension locks his telephone with level 2, he will not be able to dial
numbers starting with 112 and 03.
800050 K S P T
Parameters
K : 000..999 The code to be entered by the user for the feature with the code
797.
P : 001..999 The number of pulse prices that can be consumed by the user
T : 0..7 The line authority level for the user (see 800 040)
Notes
1- The codes and passwords defined by this program can be given to desired extensions.
Those extensions can make phone calls by using any phone within the authority level
determined by the customer feature with the code 797 until their pulse prices are all
used up.
2- Extensions that are to make calls using those codes can do that by using the lines
allocated for the 31st PBX group.
3- A user cannot make any further phone call by using that code after having used up all
pulse prices allocated for her/him. Only after re-entering a new pulse quantity, can that
code be used again.
21
DS200 Programming Guide
4- At the time when the number of pulse prices equals zero, if a call is going on, it is not
interrupted. However, a user cannot make another call using that code.
800051 K
Parameters
K : 000..999 The code to be entered by the user for the feature with the code
797.
800052
800053 K
Parameters
K : 000..999 The code to be entered by the user for the feature with the code
797.
800054
800055
22
DS200 Programming Guide
800061 P
Parameters
P : 0 PG100 connection is made to serial data (KTS) outputs on CPUKON card;
all monitoring messages are sent to CPUKON card.
: 2 All data except for the call records are sent to the DB-9 type output on the
CPUKON card.
Default Value
P=0.
Notes
1- P can be set to 1, in order to reduce the excessive load on data line (KTS), especially if
there are too many proprietary phone sets or DSS modules connected to that data line.
2- If P=2 is selected, all the data produced for monitoring purposes are sent to the DB-9
type output on the CPUKON card.
800080 P
Parameters
P : Hardware type (3 digits)
: 032 ISDN BRI (S0) Extension, Digital Extension and ISDN BRI (T0) Line cards
23
DS200 Programming Guide
Notes
1- After the EEPROM tables of the cards have been reset through that program, the cards
must be turned off and then back on, so the default parameters can be loaded to them.
(See Card On/Off program).
2- Please do not attempt to modify any EEPROM content in the system without consulting
your authorized technical service. Otherwise your system can get out of order.
Parameters
P : 001..999 Hook flash duration for analog extensions in milliseconds.
Default Value
P=600
Notes
The hook flash duration determined by this program can be adjusted according to the hook
flash durations generated by the Flash keys of the phones that are connected to the system.
Signalization Parameters:
That program adjusts the signalization parameters of the E&M cards.
800082 P S T
Parameters
P : Table row number (2 digits) (see the table below)
Default Value
Parameters for all lines have been presented in the table below:
The meanings of those parameters have been explained in DS200 Technical Reference
Guide.
Notes
1- Following the programming of the E&M parameters, all of the E&M cards must be
powered off and back on, in order to load those parameters to the non-volatile memory
fields on the E&M cards.
2- Once that program has been entered to define the E&M parameters, all those
parameters will be valid for all of the E&M cards in the exchange, which has been
powered off and on.
Example: By 800082 21 5 001, the signalization type for the 1st line on the card is
determined as Delayed Start.
800083
800085 P Q R S T
25
DS200 Programming Guide
Parameters
P : 0099 The minimum amplitude of a DTMF signal that the system
can detect is Px18.5.
S : 0099 The minimum ON duration of #/* keys signal that the system
can detect is (S+1)x6 + 10.
T : 0099 The minimum interval between #/* keys and DTMF digits is
(T+1)x6 9.
Default Value
P = 37, Q = 36, R = 30, S = 12, T = 12.
Notes
Please do not attempt to enter this program without consulting your authorized technical
service. Otherwise your system can get out of order.
800086 02
When this code is entered the cadence is tried to be detected, otherwise no detection is
made.
800087 P O1 F1 O2 F2 O3 F3 O4 F4
Parameters
P : 6 Tone cadence definition 1
26
DS200 Programming Guide
Default Value
O1, F1, O2, F2, O3, F3, F4= 010 & O4=030.
Notes
1- Example: If the cadence is 200 msec ON 200 msec OFF / 200 msec ON 200 msec OFF/
200 msec ON 200 msec OFF / 600 ms ON 200 msec OFF then the code must be
entered as:
2- After entering this program, 800086 coded program must be entered to activate the tone
detection.
3- If the cadence of the tone is not known in details then 800034 coded Tone Duration To
Drop The Lines program can be used to define an average tone duration.
800981
Notes
1- When GPBX Mode is activated, if CRL capacity becomes full when any listing device is not
connected to the system, all external calls are forbidden.
2- Once this code is dialled by the system supervisor, current and maximum call record
capacity is sent to the LCD of his feature phone in the following format:
800982 A P
27
DS200 Programming Guide
Parameters
A : The access code of the first extension in the group.
28
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0 for all extensions
Notes
1- Extensions can intrude in conversations of extensions with lower authority levels only.
2- Extensions with the intrusion authority level 5 or more can make use of the Busy Line
Drop feature with the code 798.
3- When an extension that has activated Do Not Disturb feature is called by another
extension with a higher intrusion authority level, the Do Not Disturb feature does not
function.
4- When an extension calls another one with lower intrusion authority level, the telephone
of the called extension rings with a different cadence.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
29
DS200 Programming Guide
A2 : For group programming, the number of the last extension in the group
: 6 Extension cannot call the numbers in the region specified with the
line authority table.
Default Value
All extensions have 0 authority level.
Notes
1- Extensions with restricted common pool authority levels are permitted to call common
pool numbers that are only within their authority levels.
2- The basic line call authority levels of the extensions are defined for the values of the
parameter P in the range 1 to 5. Some additional permissions or restrictions can also be
defined by setting P to 6. As an example, assume that the following programs are
entered:
800 041 7 0090 Information about the last two codes were presented in previous pages.
In that case, the extension 1113 can call long distance numbers and the numbers starting
with 0090; however, s/he cannot call the ones starting with 12.
30
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
01 for all extensions.
Notes
1- The extension group program operates in connection with the Line Matching program
with the code 801202. The Line access group is valid for line access administration of any
kind.
2- Extensions can access lines allocated to the access group defined here by the Line
Access Group program only.
Call Time-Out:
This program controls the duration for which an extension can talk during the outgoing line
calls.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
T1 and T2 = 000 for all extensions.
31
DS200 Programming Guide
Notes
1- While this program is active, whenever an extension with number A has any line call, the
conversation is automatically terminated at the end of period T1 / T2.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0, T = 0 for all extensions.
Notes
1- For cases when * / # keys have to be used to take advantage of various CO exchange
features that the system is connected to, or if it is not desired that an extension transfers
calls by her/his telephones on/off switch then this program should be utilized.
2- This program does not affect usage of function keys of LT200 and FT200 feature
telephone sets such as transfer, flash.
3- There are 19 MF receivers per rack in the system. Since one MF receiver per extension,
whose P parameter has been set as 1, is allocated throughout the conversation, the
number of extensions in the system with parameter P has been defined as 1 should be
determined by considering that situation and traffic load in the overall system.
4- Usage of the parameter P affects only extensions with DTMF telephone set.
5- The DTMF channels allocated to the extensions whose P parameters has been set as 0
are disconnected by the system 20 seconds after those extensions dial last DTMF
number. Those extensions cannot take advantage of various system features such as
Intrusion, Busy Extension Signalling, Call Back, 20 seconds after they have dialed last
DTMF number.
32
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 1, T=0 for all extensions.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0 for all extensions.
Notes
1- The operator can call any hotel room and this cannot be modified.
33
DS200 Programming Guide
2- The extensions with hotel room call permission can also take advantage of the Meet Me
feature.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P=0, T=0 for all extensions.
Follow Me Authority:
801108 A P Singular program
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P=0 for all extensions.
34
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
P : 0 The extension can use the Call Back feature with the code 81.
: 1 The extension cannot use the Call Back feature with the code 81.
Default Value
P=0 for all extensions.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
P : 0 When the extension enters in a DISA Line, s/he can access the external
line and s/he can make calls within the limits of her/his authority.
: 1 When the extension enters in a DISA Line, s/he can access the external
line, however, s/he can make calls only at the local external call
authority level.
Default Value
P = 0 for all extensions.
35
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0 for all extensions.
Notes
An extension, for whom Hot Line has been defined, must also have the hook flash authority in
order to transfer a call.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0 for all extensions.
36
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
: 1 The extension cannot make calls and receives error tone as soon as he
lifts his handset.
Default Value
P = 0 for all extensions.
Automatic Password:
A password that belongs to an extension can be changed automatically as 9999 through this
program.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Notes
If any extension in the system forgets her/his password, the password can be automatically
changed to 9999 by this program.
37
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0 for all extensions.
Pager Code:
This program defines a permanent code for the extensions pager as an extension
parameter. The extension can activate the pager after the definition of that code.
801122 A P
Parameters
A : The extension access code
Default Value
P = 000 for all extensions.
Notes
Since the permanent code of the extensions pager is an extension parameter, extensions
whose physical address have changed can continue using their pagers.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
38
DS200 Programming Guide
Default Value
P = 0 for all extensions.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
P : 0 When there is a new voice mail message, the extension telephone rings
once in every 10 minutes.
: 1 When there is a new voice mail message, the extension telephone does
not ring at all.
Default Value
P = 0 for all extensions.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
P : 0 Before listening to voice mail messages, the extension hears date &
time of the left message.
: 1 Before listening to voice mail messages, the extension does not hear
date & time of the lest message.
Default Value
P = 0 for all extensions.
39
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0 and Q = 0 for all extensions.
Notes
1- Parameter P is used during commissioning. The commissioning is based on the identity
of the extension and differs according to it.
2- If there is fax reception over VoIP lines, then Q parameter must be activated for the
extensions to which fax machines are connected.
Hot Line:
This program enables an extension to do the following operations as soon as picking up the
handset or following a 4-second delay, by defining a hot line:
801141 A P T
40
DS200 Programming Guide
Parameters
A : The extension access code (except the operator)
Default Value
P = 0 for all extensions.
Notes
1- The extensions, for whom a hot line is defined, are provided with the feature of calling
another extension or an external number without dialing.
2- If the extension is a hotel guest, the delay becomes 15 seconds for T=1.
4- If a delayed hot line has been allocated to an extension, then that extension can dial any
code within 4-second delay period. However, if no such action takes place, then the hot
line connection is done in that case.
801141 A P
Parameters
A : The extension access code (except the operator)
P : 3 The number in the field 997 of the common pool is directly called.
: 4 The number in the field 998 of the common pool is directly called.
: 5 The number in the field 999 of the common pool is directly called.
Default Value :
P = 0 for all extensions.
Notes
1- Direct-call hot line cannot be allocated to the operator or to the system supervisor.
41
DS200 Programming Guide
2- For P=3,4,5, even if all lines are busy when the extension has lifted the handset, the
system drops one of those lines and allocates it to the Direct-call hot line extension.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
: 1 Hotel room
Default Value:
P = 0 for all extensions.
Notes
1- An extension defined as hotel guest cannot make use of the following features:
b) Making entries to the private pool, making calls from the common pool, making calls
from the private pool, redialling the last number.
d) Call back
e) Intrusion
g) Do not disturb
h) Background music
2- An extension who has been defined as hotel guest cannot be the target for features of
Follow Me, Remote Follow Me. In other words, no call forwarding can be done to such an
extension in any case.
3- An extension defined as hotel guest cannot be the part of any PBX group.
42
DS200 Programming Guide
4- An emergency hot line with line access cannot be allocated to a hotel guest.
5- An extension defined as hotel guest can call all other extensions, including other hotel
guests. However, that extension can be called only by the operator, another extension
with hotel room call authority or another hotel room.
6- No hotel guests have the authority to use * / # keys by default. However, they are
enabled to use their * / # keys by 801104 coded program.
Local Extension:
An extension defined as local extension can automatically activate some features without
dialing by making assignments to number keys on her/his telephone, as well as s/he can
make one-touch dialing.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
: 1 Local extension
Default Value
P = 0 for all extensions.
Notes
The extensions marked as local can make one-touch operations. The private pools of the
related extension is used for this feature. The internal or external number in the memory
field of the private pool, corresponding to the key pressed by the extension, is called or the
requested service is fulfilled. No program can be assigned to the key 0.
If the entry to the private pool will be done through telephone of the extension, then this
should be done before the extension is marked as local.
Warning:
1- Local extensions must not be allowed to use * / # keys, together with their hook
switches to make hook flash.
3- If the local extension telephone is a Karel proprietary telephone, the function keys
are not used.
43
DS200 Programming Guide
1- Extensions of the same PBX group can answer each others ringing telephones by
making use of the feature PBX Group Call Pick Up.
2- If A and B are in the same PBX group, when the extension A receives a call request while
s/he is busy or the request has not yet been answered after the telephone rang three
times, the call request is forwarded to the extension B.
3- Extensions in the same PBX group can activate the Parallel Extensions feature. Hence,
when one of the extensions in the PBX group receives a call request, the telephones of
the first four extensions in the group will ring simultaneously.
801160 A B
Parameters
A : The access code of the extension to be included in the PBX group.
B : The access code of the extension following the extension to be included in the
PBX group.
Cancellation
801160 A A
Default Value
No extension PBX group has been defined.
Notes
1- According to the mode at which the program is entered, different PBX groups for night
and day modes can be defined separately.
2- By entering that code more than once, extensions in desired number can be included in a
PBX group. Here, it is essentially important that the entered extensions must form a
chain. Therefore, the last member of the group must be forwarded to the first member. If
that condition is not fulfilled, then that feature of the exchange may not fully satisfy
customers and problems may occur.
Example : If extensions with numbers 1112, 1113 and 1114 are to be included in the same
PBX group, the following programs should be entered:
801 160 1112 1113, 801160 1113 1114, 801 160 1114 1112
3- In order to discard an extension from the PBX group, the program 801 160 A A should be
entered, where A is the extension access code, and the chain should be preserved. The
previous and the next extensions in the group must be related with the code 801 160.
44
DS200 Programming Guide
801 160 1112 1113, 801 160 1113 1114, 801 160 1114 1115 and 801 160 1115 1112 have
been entered for a PBX group. In that case, the following codes must be entered in order
to discard 1114 from the PBX group:
4- In order to cancel all of a PBX group, each and every member of the group must be
discarded separately one by one.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
P : 0 Incoming external call requests for the extension are not distributed
uniformly within the PBX group and those requests always ring the
telephone of the extension A.
Default Value
P = 0 for all extensions.
Notes
Example: Suppose that aaa, bbb, ccc and aaa constitute a PBX group. External call requests
ring telephone of the extension aaa. In that case, if 801161 aaa 1 is entered, the first external
call request rings at the extension aaa. If the call is answered, then the second request rings
at the extension bbb. Whenever a call request is answered by an extension in the group, the
ring turn passes to the next member of the group. Normal PBX operation is not affected by
that feature.
This program determines, when an extension is called through ACD or DISA line, whether
the caller will be granted with the permission to leave message for that extension.
45
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 1 for all extensions.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0 for all extensions.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
46
DS200 Programming Guide
P : 0 During a line call, another extension can drop the line through the
feature with code 798.
: 1 During a line call, another extension cannot drop the line through the
feature with code 798.
Default Value
P = 0 for all extensions.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
P : 0 Other extensions can warn the extension through ear while s/he is busy.
: 1 Other extensions cannot warn the extension through ear while s/he is
busy.
Default Value
P = 0 for all extensions
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
47
DS200 Programming Guide
: 0 The extension does not belong to any group. Normal operation mode.
Default Value
P = 0 for all extensions.
ACD Parameters:
The extension parameters in external automatic call distributor operation can be
programmed through this facility.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
: 10 The extension does not have the authority to forward his telephone to
ACD.
Default Value
P = 00 and 10 for all extensions.
Notes
1- The extensions that are connected to ACD should be included in a PBX group.
2- For example: Extensions aaa, bbb, ccc and ddd are connected to ACD:
b) aaa is marked as the first extension connected to ACD by the 800012 coded facility.
c) By activating the 801167 coded program by the parameter value 01; bbb, ccc and ddd are
marked as the other extensions connected to ACD.
d) By activating the 801167 coded program by the parameter value 11, authority is given to
extensions that want to take benefits of ACD (like call forwarding on busy or no answer).
48
DS200 Programming Guide
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
Default Value
P = 0 for all extensions.
Notes
This program should be activated so that called number information coming from the ISDN
line can be sent to the ISDN BRI extension connected to the fax server.
801169 A B
Parameters
A : The access code of the extension to be included in the Call Pick Up group.
B : The access code of the extension following the extension to be included in the
Call Pick Up group.
Cancellation
801169 A A
Default Value
No call pick up group has been defined.
Notes
1- According to the mode at which the program is entered, different call pick up groups for
night and day modes can be defined separately.
49
DS200 Programming Guide
2- By entering that code more than once, extensions in desired number can be included in a
call pick up group. Here, it is essentially important that the entered extensions must form
a chain. Therefore, the last member of the group must be forwarded to the first member.
If that condition is not fulfilled, then that feature of the exchange may not fully satisfy
customers and problems may occur.
Example : If extensions with numbers 1112, 1113 and 1114 are to be included in the same
call pick up group, the following programs should be entered:
801 169 1112 1113, 801169 1113 1114, 801 169 1114 1112
3- In order to discard an extension from the call pick up group, the program 801 169 A A
should be entered, where A is the extension access code, and the chain should be
preserved. The previous and the next extensions in the group must be related with the
code 801 169.
801 169 1112 1113, 801 169 1113 1114, 801 169 1114 1115 and 801 169 1115 1112 have
been entered for a call pick up group. In that case, the following codes must be entered
in order to discard 1114 from the group:
4- In order to cancel all of a call pick up group, each and every member of the group must
be discarded separately one by one.
Parameters
A : The extension access code
A1 : For group programming, the number of the first extension in the group
A2 : For group programming, the number of the last extension in the group
P : 0 When a line call request is not answered, call transfer to the PBX
group does not take place.
: 1 When a line call request is not answered, call transfer to the PBX
group takes place.
R : 0 When an internal call request is not answered, call transfer to the PBX
group does not take place.
50
DS200 Programming Guide
: 1 When an internal call request is not answered, call transfer to the PBX
group takes place.
S : 0 If the call request is from the line and the extension is busy, call
transfer to the PBX group does not take place.
: 1 If the call request is from the line and the extension is busy, call
transfer to the PBX group takes place.
Default Value
P=1, R=1, S=1, T=1.
Parameters
A : The access code of the first extension of the PBX group.
A1 : For group programming, the number of the first extension of the first PBX
group.
A2 : For group programming, the number of the last extension of the last group.
P : 0 When a line call request is not answered, call transfer to the PBX
group does not take place.
: 1 When a line call request is not answered, call transfer to the PBX
group takes place.
R : 0 When an internal call request is not answered, call transfer to the PBX
group does not take place.
: 1 When an internal call request is not answered, call transfer to the PBX
group takes place.
S : 0 If the call request is from the line and the extension is busy, call
transfer to the PBX group does not take place.
: 1 If the call request is from the line and the extension is busy, call
transfer to the PBX group takes place.
51
DS200 Programming Guide
Default Value
P=1, R=1, S=1, T=1.
801198 P
Parameters
P : The extension or line access code.
Notes
1- This facility can only be used when GPBX mode is activated.
2- Once this code is dialled by the system supervisor, the number of currently used
metering pulses and the account valid for the current month is sent to the LCD of his
feature phone in the following format:
800198 | number of currently used metering pulses | the account valid for the current month
Toll Account:
It allows defining toll account for extensions and lines on a monthly basis.
Parameters
P : The extension or line access code.
P1 : For group programming, number of the first extension or line in the group.
P2 : For group programming, number of the last extension or line in the group.
: 3 Account for metering pulses that can be used until the end of the
month.
52
DS200 Programming Guide
Default Value
No accounts are defined for extensions and lines.
Notes
1- This facility can only be used when GPBX mode is activated.
2- By activating this code by Q=2, the main limit for number of metering pulses that can be
used in a month is defined. This limit will be valid at the beginning of each month.
3- By activating this code by Q=3, the number of metering pulses that can be used in that
month can be defined. If all of this account for a line is used before the end of the month,
then this line cannot be involved in external calls.
If the account becomes zero during an ongoing conversation, then this call is terminated.
4- If the account of a line defined by entering Q=3 becomes zero before the end of the month
and if there are other lines with account within the same PBX group, then the next calls
will be established using these lines.
5- The accounts defined by entering Q=2 and Q=3 may be different. The account defined by
Q=3 is valid for that month; at the beginning of the next month the account defined by Q=2
will be valid.
6- As the number of metering pulses in the account defined by Q=3 decrease during
external calls, the number of metering pulses in the account is automatically written in
the non-volatile memory 1 minute after each decrease in the account.
7- As using values 0 and 1 of parameter Q will change the values that are automatically set,
these values should not be used unless absolutely necessary.
53
DS200 Programming Guide
V. LINE PROGRAMS
Parameters
D : The line access code
P : 0 Out of service
: 1 In service
Default Value
P = 1, T = 1 for all lines.
Notes
Example: Some features that will be applied to the line with number 1212 and the
corresponding codes to be entered are presented below:
This program is also applicable for PRI ISDN / R2, E&M, BRI ISDN, TWT, VoIP and LB lines.
(T parameter is not used for PRI ISDN / R2, BRI ISDN, TWT, VoIP and LB lines.)
Line Parameters:
This program assigns various parameter values for a line.
54
DS200 Programming Guide
Parameters
D : The line access code
A : The access code of the extension that will be rung by the line.
: 1 The line can be accessed both by dialing 9 and by selective line access as
well.
Default Value
A=1110, P=1, T=1 for all lines.
Notes
1- P=0 assignment is useful especially when line D is connected to an extension of another
exchange in order to maintain an exchange-exchange connection.
3- If a DISA line on which call authorities are not checked by T=0 is used, an external line
can be accessed without the need to dial the extension number and password.
4- Different ringing extensions can be defined for line D in night and day modes. If the
program code is entered in day mode, then ringing extension definition is valid only for
daytime. On the other hand, if the program code is entered in night mode, then ringing
extension definition will be valid only for night mode.
5- Parameter P of this program can be used for LB and TWT lines as well.
55
DS200 Programming Guide
Parameters
D : The line access code
Default Value
G = 01 for all lines.
Notes
1- G=01,,32
Following each line access group number entry, the system allows other access group
number entries, instead of emitting internal dial tone. Hence, upon entering that
program once, it is possible to assign one line to 32 access groups in a single
programming session. If line D is to be assigned to less than 32 access groups, then the
telephone should be hung up after the last access group number entry.
Examples :
- 801 202 1336 01 02 03, then hang up. That assigns line 1336 to access groups 01,02 and
03.
- 802 202 1338 1341 02, then hang up. That assigns lines 1338, 1339, 1340 and 1341 to
access group 02
3- This program is also applicable for PRI ISDN / R2, E&M, BRI ISDN, TWT, VoIP and LB
lines.
801203 D E
Parameters
D : The access code of the line to be added on the PBX group.
E : The access code of the line that will follow the line to be added on the PBX
group.
Default Value
No line PBX group has been defined.
Cancellation
801203 D D
56
DS200 Programming Guide
Notes
1- By entering the code more than once, it is possible to add lines in desired quantity on a
line PBX group. Yet those lines must form a chain. That means the last member of the
PBX group must be forwarded to the first member in the group.
2- In order to discard line D from a PBX group, the code 801 203 D D should be entered and
the previous and the next line in the group must be related by the code 801 203 in order
to preserve the chain.
801 203 1334 1335, 801 203 1335 1336, 801 203 1336 1337 and 801 203 1337 1334 have
been entered for a PBX group. In that case, the programs below should be entered in
order to discard the line 1336 from the PBX group:
3- In order to cancel a whole PBX group, the program 801 203 D D must be entered for each
line one by one.
4- This program is also applicable for PRI ISDN / R2, E&M, BRI ISDN, TWT, VoIP and LB
lines.
Parameters
D : The line access code
Notes
1- DTMF telephone set is required in order to dial extension numbers for making calls
through DISA/ ACD line.
57
DS200 Programming Guide
2- If no extension number is dialed within 15-second period during calls through DISA line,
then the caller is transferred to the operator or to the ringing extension. If that
transferred call is not answered within 6 ringing periods, then the line is automatically
released.
3- A DISA-line caller
- Can refresh special DISA dial tone by pressing * key, so that s/he can call another
extension in case the called extension is busy or does not answer.
4- If an extension called through DISA line is busy or does not answer, the system gives
another 15 seconds to the caller to call another extension. 9 such attempts can be done.
If no connection has been established after the 9th try, the call is transferred to the
operator or to the ringing extension. If, furthermore, that transferred call is not answered
within 5 ringing periods, then the line is automatically released.
5- If the operator does not activate the ACD, then the ACD lines function as normal lines.
6- If a caller through ACD line does not dial an extension number while receiving special
DISA tone, then s/he is transferred to the operator or to the ringing extension. If that
transferred call is not answered within 6 ringing periods, then the line is automatically
released.
7- If polarity reversal facility has not been set by CO in a line defined as DISA / ACD, even if
caller hangs up during dialing step, then the call rings at the operator and the operator
receives CO tone when s/he answers the call. However, if CO has set polarity changing
property in that line, then, in that case, when the caller party hangs up, the polarity of the
line will change and the exchange, which detects this, will drop that line. Hence, invalid
call requests to the operator will be blocked.
Parameters
D : The line access code
58
DS200 Programming Guide
Default Value
P= 00, R=13, S=14, T=15.
Notes
1- While the system is in the night mode, the night greeting menu will be active instead of
the day greeting menu.
DISA Parameters:
They determine the consequences of operations of a caller who calls through a line marked
as DISA.
Parameters
D : The line access code
Default Value
P = 0, T= 0 for all lines.
Notes
This program is also applicable for LB lines.
59
DS200 Programming Guide
Parameters
D : The line access code
31 Conversation is limitless.
Cancellation
801207 D *
Default Value
P = 04 for all lines.
Notes
This program is also applicable for PRI ISDN / R2, E&M, BRI ISDN, TWT, VoIP and LB lines
Parameters
D : The line access code
Default Value
P = 0, T = 0 for all lines.
Notes
1. While P=0, if the dialed number:
60
DS200 Programming Guide
- Starts with 1, then the number is transmitted to the line after dialing at least 3 digits
(emergency numbers),
- Is 0, then the number is transmitted to the line after dialing at least 11 digits (long
distance),
- Is 2..9, then the number is transmitted to the line after dialing at least 7 digits (local).
2. As long as calls through E&M lines are concerned, when the caller dials 9 to access a
line, one of the lines allocated to the extension group 31 is assigned to that person.
Parameters
D : The line access code
Cancellation
801209 D *
Default Value
No price has been determined.
Notes
1- A serial printer can print costs (calculated over the unit price that has been determined)
of calls, provided that CO metering pulse is active on lines. The unit pulse price must
have been determined for that. That unit, T can be at most 999999.
For the details of guest and personnel information, please inspect the Guest-Personnel
Selection program.
2- This program is also applicable for PRI ISDN / R2, E&M, BRI ISDN, TWT, VoIP and LB
lines.
61
DS200 Programming Guide
Parameters
D : The line access code
Default Value
P=0, T=0 for all lines.
Notes
1- Modification, which has been done is permanent.
2- All adjustments done through this program for a line are valid for all conversations on
that line.
4- For TWT, LB and expandable analog lines, parameters P and T take the values in
between 0 and 7.
Parameters
D : The line access code
62
DS200 Programming Guide
T : 0..15 The duration of delay to start sending the numbers to the line. The
duration is calculated as (T+1) x 0.5 seconds.
Default Value
P=0, T=0 for all lines.
Notes
1- If P is set as 1, then one of the tone detection channels is dedicated to the line through
out the call. Therefore, it is recommended not to enter P as 1 unless absolutely
necessary.
2- If P is set as 0 then the numbers are sent to the line after the delay specified with
parameter T. If P is set as 1 and if dial tone is received before the delay specified with
the parameter T, the numbers are sent to the line immediately.
P : 0 Equal load is not active in the line PBX group. The system
accesses the lowest numbered line.
: 1 Equal load is active in the PBX group. The least recently used
line is accessed.
Default Value
P=0 for all lines.
Notes
1- In LCR applications where specific lines are used (e.g. GSM numbers are routed to the
external line where GSM gateway exists and this external line is included within a PBX
group) equal load activated by the 800024 coded programming facility does not take
action. For these applications 801213 code must be used so that equal load is activated.
2- This program is also applicable for PRI ISDN / R2, BRI ISDN, TWT, VoIP and LB lines.
63
DS200 Programming Guide
: 1 Calls made through the line do not appear in call records. This
line can be accessed from a locked telephone without dialling
password.
Default Value
P=0 for all lines.
Notes
1- That feature is especially useful if the line is connected to another system to make an
exchange-exchange connection, or if the external calls of the line must remain
confidential
2- This program is also applicable for PRI ISDN / R2, E&M, BRI ISDN, TWT, VoIP and LB
lines.
Parameters
D : The line access code
P : 0 After the external party answers the call, the numbers are sent to the
external line with DP signalling if the line is in service with DP
signalling.
64
DS200 Programming Guide
: 1 After the external party answers the call, the numbers are sent to the
external line with DTMF signalling even if the line is in service with DP
signalling.
Default Value
P = 1 for all lines.
Notes
1- If the C.O. is producing a tone between the dialed digits, this program decides the
signalling on the line after this tone is connected.
65
DS200 Programming Guide
Ringing Extension:
This program provides definition of different ringing extensions for every PRI ISDN and R2
DDI number. When a ringing extension has been defined, a direct number that can be used
for outgoing calls from that extension has also been assigned as well.
800300 Y N A
Parameters
Y : Slot number in which PRI ISDN / R2 card has been installed. (2-digit, even
number)
N : Last 3 digits of the CO number for which a ringing extension will be defined.
Default Value
A = 1110 for all numbers.
Notes
1- An incoming call from CO rings at the extension defined according to the last 3 digits of
the number.
3- This program and the program 800 305 define direct numbers for extensions, as well as
determining the ringing extension. Therefore, the extensions can be called directly by
their own numbers and when they make an outgoing call, their numbers are transmitted
to CO.
Example 1 : If numbers of PRI ISDN line are in the range 2670200 ... 2670399, then the
permanent section is 2670 and the DDI digits are in the range 200...399 in that case. If the
ringing extensions are defined as below,
200 1120
201 1121
66
DS200 Programming Guide
202 1122
. .
. .
399 1319
the extension 1122 rings when someone calls 2670202 from outside. Likewise, if the
extension 1122 makes a line call, the system will transmit 2670202 as the caller number
information.
Example 2 : Suppose that the PRI ISDN card is in slot 4 and 2651550 is one of the
numbers. In that case, 800300 04 550 1245 should be entered in order to ring the
extension 1245 when 2651550 is called.
800301 Y N A
Parameters
Y : Slot number in which PRI ISDN / R2 card has been installed. (2-digit, even
number)
N : Last 3 digits of the CO number for which the ringing extension will be deleted.
Notes
The first slot numbers according to racks are as follows:
ACD Menus:
This program enables definition of 4 specific menus among 16 to be used for PRI ISDN / R2
card.
800302 Y N P R S T
67
DS200 Programming Guide
Parameters
Y : Slot number in which PRI ISDN / R2 card has been installed. (2-digit, even
number)
Default Value
P= 00, R=13, S=14, T=15.
Notes
1- The first slot numbers according to racks are as follows:
2- Since 1000 different numbers can be defined on a PRI ISDN line, 1000 different ACD
scenarios can be realized.
3- While the system is in night mode, the night greeting menu is automatically used instead
of the day greeting menu.
The external caller through the DISA / ACD line receives a special DISA tone for 15 seconds.
Number of an extension can be dialed within this period.
800303 Y N P
Parameters
Y : Slot number in which PRI ISDN / R2 card has been installed. (2-digit, even
number)
68
DS200 Programming Guide
Default Value
P = 0 for all numbers.
Notes
1- If a line is enabled for direct inward access, then when an incoming call request is
received through that line, the exchange automatically activates that line and emits a
special dial tone. Then, the caller can access the extension by dialing her/his number.
3- The external caller through a DISA line must use a DTMF telephone set in order to dial
extension numbers.
4- If an external caller through the DISA line fails to dial an extension number while
receiving the special DISA dial tone, then s/he is transferred to the operator or to the
ringing extension. If that transferred call is not answered within 6 ringing periods, then
the line is automatically released.
- Refresh the special DISA dial tone by pressing * key. By this way, s/he can call
another extension if the extension s/he has called is busy or not answering.
6. If the extension called through the DISA line is busy or not answering, the system gives
the caller party additional 15 seconds to call another extension. The caller party can
make 9 such attempts to establish a call. However, if s/he has not yet established a call
within 9 attempts, the call is transferred to the operator or to the ringing extension. If
that transferred call is not answered within 5 ringing periods, then the line is
automatically released.
7. More than one party can access the system simultaneously for the inward calls through a
line marked as DISA / Auto Attendant.
69
DS200 Programming Guide
DISA Parameters:
This program determines the consequences of operations realized by a party calling through
a line marked as DISA.
800304 Y N P T
Parameters
Y : Slot number in which PRI ISDN / R2 card has been installed. (2-digit, even
number)
Default Value
P = 0, T = 0 for all numbers.
800305 Y N
Parameters
Y : Slot number in which PRI ISDN / R2 card has been installed. (2-digit, even
number)
Default Value
No root number has been defined.
Notes
The first slot numbers according to racks are as follows:
70
DS200 Programming Guide
Attention!
The programs listed below, which are valid for analog lines, are also valid for PRI ISDN /
R2 lines.
801202
801203
801207
801209
801210
801213
801214
71
DS200 Programming Guide
Ringing Extension:
800350 D N A
Parameters
D : The line access code
N : The CO number which the ringing extension will be defined for (maximum 7
digits.)
Default Value
A = 1110 for all numbers.
Notes
A call request coming from CO rings at the extension that has been defined according to the
number. If the number is shorter than 7 digits, then it should be terminated with *. If, on
the other hand, the number is longer than 7 digits, then the last 7 digits are used in this case.
Example: Let the number of the BRI ISDN line be 1358 and the extension numbers be in the
range 2651100..2651199. In this case, 800350 1358 2651150 1245 should be entered in order
to make the extension 1245 ring when 2651150 is called.
Parameters
D : The line access code
ACD Menus:
800352 D N P R S T
Parameters
D : The line access code
72
DS200 Programming Guide
Default Value
P= 00, R=13, S=14, T=15.
The external caller through the DISA / ACD line receives a special DISA tone for 15 seconds.
Number of an extension can be dialed within this period.
800353 D N P
Parameters
D : The line access code
Default Value
P = 0 for all numbers.
Notes
1- If a line is enabled for direct inward access, then when an incoming call request is
received through that line, the exchange automatically activates that line and emits a
special dial tone. Then, the caller can access the extension by dialing her/his number.
3- The external caller through a DISA line must use a DTMF telephone set in order to dial
extension numbers.
73
DS200 Programming Guide
4- If an external caller through the DISA line fails to dial an extension number while
receiving the special DISA dial tone, then s/he is transferred to the operator or to the
ringing extension. If that transferred call is not answered within 6 ringing periods, then
the line is automatically released.
- Refresh the special DISA dial tone by pressing * key. By this way, s/he can call
another extension if the extension s/he has called is busy or not answering.
6. If the extension called through the DISA line is busy or not answering, the system gives
the caller party additional 15 seconds to call another extension. The caller party can
make 9 such attempts to establish a call. However, if s/he has not yet established a call
within 9 attempts, the call is transferred to the operator or to the ringing extension. If
that transferred call is not answered within 5 ringing periods, then the line is
automatically released.
7. More than one party can access the system simultaneously for the inward calls through a
line marked as DISA / Auto Attendant.
DISA Parameters:
They determine the consequences of operations of a caller who calls through a line marked
as DISA.
800354 D N P T
Parameters
D : The line access code
Default Value
P = 0, T = 0 for all lines.
Attention!
The programs listed below, which are valid for analog lines, are also valid for BRI ISDN
lines.
801202
801203
74
DS200 Programming Guide
801207
801209
801210
801213
801214
75
DS200 Programming Guide
Parameters
D : The line access code
Default Value
P = 0, T= 0 for all lines.
Notes
1- It is recommended that the E&M lines should be adjusted to receive tones, if a remote
exchange is generating a tone after a connection has been established, and furthermore,
if it supports DTMF signalling.
2- If the E&M line has been adjusted to check tones, then the numbers to be dialed must be
DTMF; otherwise, the line cannot transmit the numbers to the remote exchange.
3- If the E&M line has been adjusted to check tones, then the parameter P of the program
Call Properties does not have any effect. In other words, that parameter is not used if the
remote exchange is transmitting tone after collecting numbers during tone reception.
4- If the E&M line has been adjusted to check tones, then, as soon as a tone is received from
the remote exchange, speech channel that belongs to the E&M line is automatically
connected to the user.
5- If the remote exchange is capable of checking tones after a connection has been
established, then it is recommended that the E&M lines should be adjusted to transmit
tones.
76
DS200 Programming Guide
Parameters
D : The line access code
Default Value
P= 0 for all lines.
Attention!
The programs listed below, which are valid for analog lines, are also valid for E&M lines.
801202
801203
801207
801209
801210
801214
77
DS200 Programming Guide
As an Auto Attendant module, EVM200 can be utilized for two different purposes:
All authorized users can make use of EVM200, as a voice mail module, like an answering
machine to leave messages or to listen to the messages left for them.
An EVM200 card has totally 8 channels: 4 for listening to the messages and 4 for leaving
and/or recording messages.
The card has got some message boxes for its various different tasks :
1- 64 message boxes for informing users about their telephones. Those have been
mentioned as System Messages in this guide. The message boxes that have been
reserved for the system messages have been numbered in the range 000...063.
2- 64 message boxes for guiding external callers. Those have been mentioned as ACD
Messages in this guide. The message boxes that have been reserved for the ACD
messages have been numbered in the range 064...127.
3- 512 message boxes in order to enable users to leave messages for each other. Those
have been mentioned as Voice Mail Messages in this guide. The message boxes that have
been reserved for the Voice Mail messages have been numbered in the range 128...639.
By factory default, the first 17 ACD messages (064-082) on EVM200 is recorded for special
purposes. However, any message can be used for any purpose. If all channels have been
occupied when a message is about to be announced, then the caller hears music; if Music On
Hold is not active, however, then wait tone is emitted. The message is announced whenever a
channel is available. Message duration can be at most 40 seconds.
EVM is delivered to customers as the system messages have been recorded. Those
messages can be modified or erased. The first 28 (000-027) messages are employed for
informative purposes during the normal operation of the exchange. Other messages (028-
063), on the other hand, are date-time messages announced at the beginning while listening
to a message previously left. If all announcement channels have been occupied when a
message is about to be announced, then music, if Music On Hold is not active, then wait tone
is emitted. The message is announced whenever a channel is available.
At most 8 EVM200 cards can be installed in a DS200 system. The number of needed EVM200
cards may vary due to capacity and traffic load of the DS200.
The main idea behind increasing the number of EVM200 cards are extending the number of
the channels in order to serve more call requests simultaneously, as well as providing more
message boxes for voice mail messages. An example to clarify the topic is presented below:
Suppose that there are 4 EVM200 cards in the DS200 system. In that case, there are
78
DS200 Programming Guide
- 512 x 4=2048 message boxes for the voice mail messages in the system.
As can be seen in the example, increasing the number of cards in the system does not
increase the number of the message boxes that can be used for the system and the ACD
messages; because the same messages should be recorded on all the cards. Since it is
possible to copy messages from one card to the other, there is no need to record on each
card one by one separately.
It should be kept in mind that both the exchange and the EVM200 card must be
simultaneously in programming mode in order to do programming operations on EVM200
card.
800450 Y P
Parameters
Y : EVM200 card slot number
Notes
Prior to the operations (such as ACD/System message recording, erasing, copying) related to
EVM200, the card must be put into the programming mode.
In order to put EVM200 into the programming mode, DS200 must also be in the programming
mode. (877777)
While EVM200 is in programming mode, all program codes starting with 800 can be entered
by the system supervisor only, whereas the codes starting with 7 can be entered both by the
system supervisor and the operator.
ATTENTION!
It is recommended that the related parts of the guide should be read carefully and the
requirements should be determined in detail before starting with programming EVM200.
7559 Y
79
DS200 Programming Guide
Parameters
Y : EVM200 card slot number
Notes
1- This program can be entered only through the operator or the system supervisor
telephone, while the EVM card is in programming mode.
2- As the result, all ACD messages in the flash memory modules are erased. Silence is
received during the operation and dial tone is received after the operation.
3- The ACD function should be deactivated prior to the entry of that program.
7558 Y D
Parameters
Y : EVM200 card slot number
Notes
1- This program can be entered only through the operator or the system supervisor
telephone, while the card is in programming mode.
2- All messages in the system message flash memory module are erased. Silence is
received during the operation and dial tone is received after the operation.
3- The ACD function should be deactivated prior to the entry of that program.
7586 Y M D + Message
Parameters
Y : EVM200 card slot number
80
DS200 Programming Guide
Notes
1- This program can be entered only through the operator or the system supervisor
telephone, while the card is in programming mode. .
2- The ACD function should be deactivated prior to the entry of that program. .
3- D parameter is used only for system messages. And D parameter can take value 1 only
if the EVM200L card is enriched with an extra FLASH module for system messages to
provide the second language.
4- After the code has been dialed, short warning tone is awaited. Once the tone is received,
the message is read. Messages related to time and day are used for informing the
extension, for whom the message is left, about the time when the message was left.
5- If the entered message is already in the system, that message is automatically erased.
While the previous message is being erased, wait tone is received or music is listened to,
if that feature is active. The new message can be entered after that tone has stopped.
6- The telephone must be hung up in order to complete the message entry. It is strongly
recommended that the keys * / # should not be used for terminating the message
entry, since DTMF values of those keys are recorded as a part of the system message.
7- Considering the ACD message capacity, the entered messages should be as short and
explanatory as possible. If the ACD message capacity is exceeded during a message
entry, then the recording stops and the internal dial tone is heard again.
8- Each system message box has a predefined and fixed function. This fact should be
considered during message entry.
002, You Have Got Message. Message : If there is a message left for the extension, then
this message is announced when the handset is lifted.
003, Night Mode is Active. Message : When the system is in the night mode, if the
operator telephone goes off-hook, then this message is announced.
004, Auto-dialer is Active. Message : If the Auto-dialer is active, then this message is
announced when the handset is lifted.
005, Reminder Message : If a reminder has previously been entered through 838, then this
message is announced when the handset is lifted while the telephone is ringing at the
warning time.
81
DS200 Programming Guide
006, Unassigned Port Message : When an extension that does not exist in the system is
attempted to be called or a non-existent line is attempted to be accessed, then this message
is announced.
007, All Lines are Busy. Message : This message is announced upon a line access attempt
while all the lines are busy.
008, This Line is Out of Service. Message : This message is announced upon a line access
attempt that is out of service.
009, No authority for Line Access. Message : This message is announced when an
extension without line access authority attempts to access a line.
010, Insufficient Authority for This Call Message : This message is announced when an
extension attempts to make a call beyond her/his authority (such as long distance,
international, etc.).
011, No Authority for Restricted Number Message : This message is announced when a
restricted number, which has been entered through the accessible number by the area code
or prefix definition program, is dialed.
012, Operator Only Message : This message is announced when an operation code, which
can be normally done by the operator only, is dialed by an extension.
013, System Supervisor Only Message : This message is announced when an operation
code, which can be normally done by the Admin only, is dialed by an extension.
014, No Authority for This Feature. Message : This message is announced when an
extension dials a feature code which is beyond her/his authority.
015, No Calls to Pick up Message : This message is announced when a non-existent call is
attempted to be picked up by 82+ extension no.
016, System is out of Programming Mode Message : This message is announced when a
program is attempted to be entered while the system is not in the programming mode.
017, All Lines are out of Service. Message : If the Admin lifts the handset while all the
lines are out of service, then this message is announced.
018, Phone Locked Message : If the code (877777) for entering into the system programming
mode is dialed even though the Admin telephone is locked, then this message is announced.
019, Erroneous Operation Message : This message is announced when an invalid operation
code is dialed.
020, Wrong password Message : This message is announced if a wrong password is entered
during password change (836), phone locking and unlocking.
023, Room is Clean. Message : This message is announced when the status of a clean
hotel room is inquired (731).
82
DS200 Programming Guide
024, Room is Being Cleaned. Message : This message is announced when the status of a
hotel room which is being cleaned is inquired (731).
025, Room is Dirty. Message : This message is announced when the status of a dirty hotel
room is inquired (731).
The date-time messages consist of numbers and months and their lengths are limited. (0.5-1
second). The date-time messages are below:
Example : "Welcome to our company. If you know the extension number please dial right
now; or please wait for the operator.
Call forwarding to specific sections is possible by making use of the grouping program of the
PBX. For instance, if 112, 113, 114 are telephones of the accounting department; 123, 124,
125 are telephones of the sales department; 140, 141, 142 are telephones of the technical
service department; then those three departments can be grouped by the program 805 and
the greeting message may take such a form:
" Welcome to our company. Please dial 112 for the accounting, 123 for the sales, and 140 for
the technical service departments; or please wait for the operator."
065 Missing Digit Message: This message is announced when a dialed number is
incomplete at any stage.
83
DS200 Programming Guide
Example : "You have dialed an incomplete number. Please try again. " .
066 - Busy Message: If the called extension is busy, then this message is announced. After
the message below has been announced, the caller can call back by dialing 5 or can leave
message by dialing 6.
Example : "The extension you are calling is busy right now. You can dial 5 to call back, dial 6
to leave a message, call another extension or wait for the operator. "
If the caller decides to call back after the announcement, then this can be done by dialing 5
during the silence following the announcement. Afterwards, the announcement related to
the place of the caller in the queue is announced to her/him.
067 No Answer Message: If the called extension does not answer within 20 seconds, then
this message is announced.
Example : " The extension you are calling is not answering. You can dial 6 to leave a
message, call another extension or wait for the operator. "
068 Wrong Number Message: This message is announced when a dialed number is wrong
at any stage.
Example : "You have dialed a wrong number; please try again. ".
069 Hold On Message: When a busy extension is called back, (by dialing 5, after listening to
the Busy Message), this message is announced and then music is emitted to the caller if it
has been activated, or the wait tone is emitted otherwise.
No number can be dialed during the announcement of that message. Music or the wait tone
is emitted after the message.
The call is transferred to the extension, who has been called back by dialing 5, as soon as
s/he becomes available.
Example : "No direct connection is possible to the extension you are calling. Please wait for
the operator or call another extension. "
071 Transfer to the Operator Message: After a call request has been answered by EVM,
there is a limit, which has previously been determined through programming, for trials until
a conversation is established. If that limit is exceeded, then that message is announced. The
call is transferred to the operator, afterwards.
Example : "Please hold on; you are being connected to the operator. "
072 Night Mode Greeting Message: While the system is in the night mode, this message is
announced to answer incoming call requests. The request is transferred to the operator,
afterwards.
Example : "Our company is closed right now. Please dial 7 if you would like to leave a
message. ".
073 DISA Message: When a call request is received through a line on which DISA is active,
first this message is announced, then a special dial tone is emitted.
Example : "Please dial the extension if you know the number; or wait for the operator. "
84
DS200 Programming Guide
074 Password Request Message: This message is announced when an extension attempts
to listen to the messages left for her/him by dialing 8646 or 8645, and her/his password is
requested, if there is one.
075 Ringing Message: If an extension, which is called through ACD, is busy during a call
request and is called back, then this message is announced when s/he is available.
Example: Ringing.
076 The Operator is Busy. Message: If the operator is busy when the call request is
transferred to the operator, then the caller receives music or the wait tone. However, the
duration of those are 2.5 minutes. This message is announced, if the operator is still busy at
the end of that period.
079 The 1st Person in the Queue. Message: Announced if you are the first person to call
back.
080 The 2nd Person in the Queue. Message: Announced if you are the second person to
call back.
081 The 3rd Person in the Queue. Message: Announced if you are the third person to
call back.
082 The 4th Person in the Queue. Message: Announced if you are the fourth person to
call back.
The ACD message box numbers mentioned above are just factory defaults. Those
messages are or similar ones can be erased and recorded to the boxes 064-095 upon
wish.
If any one of those messages is not recorded, dial tone is emitted again for the cases that
message should be announced; or some other operation is initiated according to the
situation.
The other Messages : Other messages can be recorded to the boxes 083...127 for other
purposes through the feature with the code 7586 Y M. Yet you may need to increase the flash
memory capacity in order to record such additional messages.
7585 Y M D
Parameters
Y : EVM200 card slot number
M : 000..063 box numbers of the system messages, 064..127 box numbers of the
ACD messages
85
DS200 Programming Guide
Notes
1- If there are no messages in the box with number M, then the dial tone is emitted.
2- If all the announcement channels of EVM are busy at the moment, then a caller receives
music or the wait tone. The message is announced as soon as one of the channels is
available.
4- This programming facility does not support listening to date and time messages for the
time being.
7557 Y M D
Parameters
Y : EVM200 card slot number (2 digits)
M : 000..063 box numbers of the system messages, 064..127 box numbers of the
ACD messages
Notes
1- The wait tone or music is heard during the erasing operation and the dial tone is received
upon completion of the operation.
2- This program can be entered only through the operator or the system supervisor
telephone, while the card is in programming mode.
3- The ACD function should be deactivated prior to the entry of that program.
7560 Y1 Y2 0 M1 M2
86
DS200 Programming Guide
Parameters
Y1 : EVM200 card slot number (2 digits)
M2 : The number of the message box on the target EVM card (000..127)
Notes
1- This program can be entered only through the operator or the system supervisor
telephone, while the card is in programming mode.
2- M1 should be equal to M2 under normal conditions.
3- If there is already a message in the target message box, then it is erased by the copied
message from the source card.
4- If there is the optional module for system messages in 2nd language, the messages in this
extra module are not copied other cards.
5- The ACD function should be deactivated prior to the entry of that program.
7560 Y1 Y2 2
Parameters
Y1 : EVM200 card slot number (2 digits)
Notes
1- This program can be entered only through the operator or the system supervisor
telephone, while the card is in programming mode.
2- If there are already messages in the target message boxes, then they are erased by the
copied messages from the source card.
3- The ACD function should be deactivated prior to the entry of that program.
87
DS200 Programming Guide
800451 P K M
Parameters
P : 00..05, 08..11 constant message number
Default Value
For P = 00, M = 068
For P = 01, M = 068
For P = 02, M = 065
For P = 03, M = 070
For P = 04, M = 076
For P = 05, M = 071
For P = 08, M = 079
For P = 09, M = 080
For P = 10, M = 081
For P = 11, M = 082
Notes
The conditions during which the constant ACD messages are announced are as follows:
0. Dialing a wrong number during an extension number entry.
88
DS200 Programming Guide
Total Penalty:
An external caller who has connected to the ACD sometimes may not access the extension
s/he is calling due to some reasons (like busy, wrong number etc.). Some penalty points are
assigned for such cases. If the caller faces more erroneous situations than that has been
defined in the system (the total penalty), then s/he is transferred to the operator.
The penalty list:
1. Dialing an incomplete number = 1 penalty point
2. Dialing an invalid number = 2 penalty points
3. Dialing an inaccessible number = 1 penalty point
4. No answer from the called extension = 2 penalty points
89
DS200 Programming Guide
800452 P
Parameters
P : 00..99 the total penalty value
Default Value
P = 04
Notes
Example: The factory default value of that parameter is 4. Hence, in case an external caller
dials wrong numbers twice (4/2=2), the call request is transferred to the operator. If that
value is entered as 8, then in case the caller dials wrong numbers for (8/2=4) 4 times, the call
request is transferred to the operator.
Changing Language:
A choice can be done between two message boxes through this program, in order to
determine the language that will be used for the menus. The language options are defined by
the programmer during recordings of the ACD messages. The ACD message boxes (064..127)
have been separated into two groups. The first group consists of the boxes in the range
064...095, and the second group in the range 096...127. The ACD messages that will be
recorded into the second group in another language should follow the same order as for the
first group.
800453 P
Parameters
P : 0 The first language (Turkish), message boxes 064..095
: 1 The second language (optional), message boxes 096..127
Default Value
P = 0.
Notes
The message boxes 064...127, which are reserved for the ACD messages, have been divided
into two in order to provide recording in two languages. In that case, the recording in the first
language should be done into the boxes 064-095, and the recording in the second language
should be done into the boxes 096-127 by preserving the same order.
The opening language of the ACD, when it answers a call request, is determined through this
parameter. P can take values 0 and 1. The opening language will be the one that has been
used in boxes 064-095, if the value 0 has been entered. On the other hand, if the value is set
to 1, then the opening language will be the one that has been used in boxes 096-127.
If a user chooses change the language from the menu, then the language switches for that
specific session only, ie., if P=0, then it becomes 1 and vice versa.
Example: If both Turkish and English ACD options will be used in your company, and if the
opening language of the ACD will be Turkish, then the messages in Turkish should be
90
DS200 Programming Guide
recorded into the boxes 064...095 and the messages in English should be recorded into the
boxes 096...127.
The English equivalent of the message in box 064 should be recorded into the box 096,
The English equivalent of the message in box 065 should be recorded into the box 097,
:
The English equivalent of the message in box 095 should be recorded into the box 127.
Time-Out Durations:
This program determines the time-out durations for normal and special messages.
800454 S1 S2
Parameters
S1 : 01..99 The normal time-out duration in seconds (for normal messages)
S2 : 01..99 The special time-out duration in seconds (for special messages)
Default Value
S1 = 8, S2 = 4
Notes
This program determines the maximum time intervals during which an external caller could
wait before dialing, after dialing options have been presented to her/him. There are two types
of time-out durations, namely the normal time-out and the special time-out duration.
If the message announced to the caller has been defined as special message (see the
section Menu Entry Message), and if that caller has got into selection state after having
listened to the special message, then the system waits until the special time-out duration is
up. On the other hand, if the announced message has not been defined as special, then the
waiting period is the one determined for the normal time-out.
To clarify the topic with an example, let the normal time-out duration is 8 seconds and the
special time-out duration is 4 seconds. If an extension waits at the first entry menu, then
s/he is transferred to the operator at the end of 8-second period. After getting information by
dialing 1 or 2 (if those informative messages are special messages), if the extension is again
at the selection state, then the line is dropped after waiting for 4 seconds.
91
DS200 Programming Guide
Each menu has an entry message. That entry message can be selected among the ACD
messages (064..127) to be announced or not to be announced.
That message can be classified as special or normal. The differences between a normal and
a special message can be described as follows:
- After the normal message has been announced to the caller, there is a programmable
time interval in which the caller should dial a number (normal time-out period). If the
caller fails to dial a number within the specified period, then the call request is
automatically transferred to the menu-specific ringing extension. The caller receives a
special dial tone during the normal time-out period.
- After the special message has been announced to the caller, there is another
programmable time interval in which the caller should dial a number (special time-out
period). If the caller fails to dial a number within the specified period, then the line is
released. The caller receives a special dial tone during the special time-out period.
The entry message can be classified as ignorable or protected message, as well. The
difference between those two message types can be described as follows:
- While an ignorable message is being read to the caller, the caller can skip the rest of the
message and can take another action.
92
DS200 Programming Guide
- While, on the other hand, a protected message is being read to the caller, the caller
cannot take any other action.
After the caller has listened to, or has ignored, the special or normal type message, an
action decision is initiated upon pressing a key.
The Action Decision is made according to an action table determined through programming
and is initiated upon pressing a key.
Different Action choices:
1- Moving on to the next menu.
2- Access by a single key.
3- Forming a valid access code by collecting the numbers that is dialed by the caller.
4- Exiting from the ACD to the DISA line.
5- Changing the menu language.
6- Leaving message to an extension that is busy or that does not answer.
7- Calling a busy extension back.
8- Leaving message to the operator and exiting.
9- Waiting for another number to make action decision by ignoring a dialed digit.
The action decision is the brain of a menu and the user is led to any action field according to
the result of that action decision.
800455 N P M
Parameters
N : 00..15 Menu page number
P : 0 No message is announced.
Default Value
For N = 00, M = 064
For N = 13, M = 072
For N = 14, M = 067
For N = 15, M = 066
93
DS200 Programming Guide
Notes
If the parameter P is set to 0 , then that means no message will be announced to the caller.
In that case the programmer receives dial tone without entering the kkk parameter at the
end.
If the parameter P is set to 1 , then that means a message will be announced upon entering
the menu in that case. The caller is not allowed to press a key and proceed to an action
before the announcement is complete. Besides, the caller is automatically transferred to the
operator at the end of the normal time-out period, unless s/he takes an action following the
announcement.
If the parameter P is set to 2 then that means a message will be announced upon entering
the menu in that case. The caller is not allowed to press a key and proceed to an action
before the announcement is complete. Besides, if the caller waits until the end of the special
time-out period, without taking an action, then the line will be dropped.
If the parameter P is set to 3 then that means a message will be announced upon entering
the menu in that case. The caller may take another action by pressing a key while listening to
the announcement, before the end of it. Moreover, the caller is automatically transferred to
the operator at the end of the normal time-out period, unless s/he takes an action following
the announcement.
If the parameter P is set to 4 then that means a message will be announced upon entering
the menu in that case. The caller may take another action by pressing a key while listening to
the announcement, before the end of it. Besides, if the caller waits until the end of the
special time-out period, without taking an action, then the line will be dropped.
The menu entry message can be selected as special message, as will be mentioned later in
the section action list / the next menu.
Action Table:
This program allows an action table to be chosen, so that the program code can change
according to the action that has been chosen.
94
DS200 Programming Guide
Parameters
N = 00..15 : The Menu page number
T = 0..9 : The first digit that the caller will dial. (decision point)
95
DS200 Programming Guide
Default Value
For the Menu 00 For the Menu 13
For T = 0, H = 03 For T = 0, H = 09
For T = 1, H = 03 For T = 1, H = 09
For T = 2, H = 03 For T = 2, H = 09
For T = 3, H = 09 For T = 3, H = 09
For T = 4, H = 09 For T = 4, H = 09
For T = 5, H = 09 For T = 5, H = 09
For T = 6, H = 09 For T = 6, H = 09
For T = 7, H = 09 For T = 7, H = 06, P1 = 1, P2 = 083
For T = 8, H = 09 For T = 8, H = 09
For T = 9, H = 04 For T = 9, H = 04
Notes
The action that a user will take in any menu is automatically determined according to the
first digit s/he dials.
The actions that will be taken according to the digit the caller dials should be assigned to the
Action Table by choosing one of the actions, which have been defined in the Action List for
each digit.
96
DS200 Programming Guide
Waiting without pressing any key is a selection, too, for the user. In that case the operator is
called by exiting menu. For each menu page, different ringing extension access codes can be
entered in order to determine which extension the line will be automatically transferred to.
02 : Single-key Call
a) A call is initiated as soon as pressing a key and an extension is immediately called. That
feature has a single parameter.
The access code: A valid extension access code (the ringing extension)
b) If the called extension is busy, then the process jumps to the Busy Menu, returns to the
same menu and starts again from the entry message.
c) If the called extension does not answer, the process jumps to the No Answer menu,
returns to the same menu and starts again from the entry message.
03 : Collecting Numbers
The numbers that are dialed during the normal or special time-out periods are collected by
the system. Then the system checks whether the dialed code is a valid access code.
a) If that is a valid access code, then the related extension is called.
I. If the called extension is busy, then the process jumps to the Busy Menu, returns
to the same menu and starts again from the entry message.
II. If the called extension does not answer, the process jumps to the No Answer
menu, returns to the same menu and starts again from the entry message.
b) If the dialed code is not a valid access code or if it is the code of an inaccessible
extension, then, in that case:
I) If the access code digit quantity is not enough, then the Incomplete Number
constant message is announced and the process returns to the Action Decision step.
II) If the access code is invalid, then the Wrong Number constant message is
announced and the process returns to the Action Decision step.
III) If the access code belongs to an inaccessible extension, then the Inaccessible
Extension constant message is announced and the process returns to the Action
Decision step.
04 : Exit to DISA
The user receives the DISA dial tone, upon exiting the Auto Attendant. Then s/he can take any
action that a normal user is authorized to do on DISA lines.
97
DS200 Programming Guide
05 : Change Language
Another language is selected upon pressing the related key. In that case:
a) The system converts the language of the messages in all menus to another language.
b) The process continues in the other language, starting from the entry of the same menu.
Once the language has been changed, the later language will be valid until the caller exits
the Auto Attendant.
06 : Leave Message:
a) The system puts the caller into the queue for the busy extension and, if it has been
programmed in that way, announces a message like Please wait.
b) The system lets the caller leave a message with a length of at most 30 seconds.
c) The process continues through the entry of the same menu. That action can be taken in
the Busy and No Answer menus only. A message like You can leave your message after
the beep when you press the key... may be announced.
07 : Call Back
a) The system puts the caller into the queue for the busy extension and, if it has been
programmed in that way, announces a message like Please wait.
b) The system announces the Queue Information constant message to the caller.
c) If the caller waits for 40 seconds,
I. If the extension is still busy, then the process returns to the Busy Menu.
II. If the extension does not answer the call request, even if s/he has hung up, then
the process returns to the No Answer Menu.
09: No Action
The key is ignored. No action is taken. Another number is awaited for the action decision.
800457 N A
98
DS200 Programming Guide
Parameters
N : 00..15 The menu page number
Default Value
A = 1110
Parameters
T : 0 The system message gain
Default Value
For T = 1, S = 3,
For T = 0, S = 3.
99
DS200 Programming Guide
Network Settings:
Used to make the network settings of LAN Adaptor card.
800470 P T
Parameters
P : 1 IP number
: 4 Port number
P 1 IP number of 12 digit
Notes
Example:
If 800 470 1 192168002235 is entered, IP number is set to 192.168.2.235.
If 800 470 3 255255255000 is entered, subnet mask is set to 255.255.255.0.
If 800 470 4 15000 is entered, the port number is set to 15000.
After making these settings, a short cut for the ADMIN200 program must be created and the
following must be add at the end of the target line in the Properties of the short cut.
/lan:192.168.2.235:15000. ADMIN200 must be run through this short cut.
100
DS200 Programming Guide
Network Settings
Used to make network settings of VoIP card.
800480 P R
Parameters
P : 1 IP address
Notes
1. When defining the addresses, the empty digits should be entered as 0. Example: If the
IP address is 192.168.2.35, then the code 800480 1 192168002035 should be entered.
2. After the program code activation, the values are automatically set for the first VoIP card
on the system. If there are more than one card on the system, successive IP addresses
will again automatically be set for these cars. Gateway and Subnet mask addresses
should be programmed as the same for the different cards on the system.
3. It is recommended to Ping to the cards from a PC on the same LAN to verify the
programming.
101
DS200 Programming Guide
As the LCR facility is very powerful but detailed, most of the settings are made through
ADMIN200 program. The programs that can be entered through the system supervisors
telephone are given below:
LCR Activation:
The LCR parameters which are set via ADMIN200 program can be activated or deactivated by
this program.
800803 P
Parameters
P : 0 LCR parameters are not active
800804 A B C D E F G H
Parameters
A : 0-63 Access authority for the extensions with local line access authority.
B : 0-63 Access authority for the extensions with long distance line access
authority.
C : 0-63 Access authority for the extensions with international line access
authority.
D : 0-63 Access authority for the extensions with line access authority level 4.
E : 0-63 Access authority for the extensions with line access authority level 5.
F : 0-63 Access authority for the extensions with line access authority level 6.
102
DS200 Programming Guide
G : 0-63 Access authority for the extensions with line access authority level 7.
H : 0-63 Access authority for the extensions with line access authority level 8.
103
DS200 Programming Guide
The programs related to the flexible numbering are entered while the system is in the
programming mode. Since those data are stored separately from other parameters, even if
the system is reset through the code 800002 9, they retain their most recent values.
800900
Notes
If a new numbering plan coincides with the previous or the default ones at too many points,
then it may be too cumbersome to enter the new plan by the code 800903 A E, so all
extension and line numbers are cleared through the code 800900. Then it will be necessary
to enter new access codes for extensions and lines all over again. If the number of any
extension is not entered after dialing that code, then one cannot access that extension.
800901
Notes
1- If there are too many coincidences between the flexible numbering plan to be entered
and the current feature access codes, then entry of new feature codes can be facilitated
by entering that code.
2- You can delete all feature access codes by using that code. However, the programming
access prefixes 800, 801 and 802 are not deleted when that code is used.
800902
104
DS200 Programming Guide
Notes
Whatever the capacity of the system is, the access codes of all extensions are contained in
the table. For the cases when a change will be done on a previously entered numbering plan,
that program must not strictly be entered, or all the previously entered numbers will take on
their default values. Since the default values for all extensions are loaded, regardless of the
system capacity, following the entry of the program 800902, the numbers of non-existing
extensions should not be assigned to the existing extensions. Hence, it is necessary to delete
those non-existing extensions prior to number assignment. Besides, in case things go wrong
while entering a numbering plan, it is possible to reset through this program, if necessary.
800903 H E
Parameters
H : The access code of the extension or the line.
Notes
1- A new access code can be entered for any extension or a line through this program. If the
entered access code is of 8 digits, then dial tone or the invalid operation tone is received
after entering the last digit. If dial tone is received, then the entered code does not
coincide with any other code and the operation has been accomplished. On the other
hand, if the invalid operation tone is received, then that means the code coincides with
other codes, thus the operation has not been accomplished.
2- If the entered access code is of less than 8 digits, then the operation should be
terminated with * key. (If the operation is attempted to be terminated by hanging up,
then it cannot be accomplished.) In that case, either dial tone or the invalid operation
tone is received. For the invalid operation case, either the coincided code must be
replaced by another, or must be temporarily deleted. Clearing access codes through the
code 800900 facilitates the entry of a numbering plan with many coincidences with the
previous codes. (see Clearing Access Codes)
3- The access code of the line with number H is cleared after entering 800903 H,
terminating the entry by * and receiving dial tone, respectively. That line can no longer
be accessed, when another extension is called or external call is made through that line,
nothing is transmitted as the access code of the line. Clearing access code can be applied
as a temporary action in case there is code coincidence.
4- For example, suppose you would like to change the access code of an extension from
1112 to 1144, and at the same, you would like to change access code of another extension
from 1144 to 1112. Both of the actions 800903 1112 1144 * and 800903 1144 1112 * will
result with error. In that case, the programs 800903 1144 *, 800903 1112 1144 * and
800903 1144 1112 *, respectively, should be entered.
5- If the Karel digital telephone set is utilized for programming, then the coinciding number
will be displayed, in case of a coincidence.
105
DS200 Programming Guide
800904 H1 H2 E
Parameters
H1 : The access code of the first line or the extension in the group.
H2 : The access code of the last line or the extension in the group.
E : The new access code to be assigned to the first line or extension of the
group. (minimum 1, maximum 8 digits)
Notes
1- Numbers are automatically assigned by starting from E and incrementing by 1 to all lines
between H1 and H2 .
2- In case E is of less than 8 digits, the program code must be terminated with *.
Example: When 800906 1110 1125 2110* is entered, the access codes that were once
between 1110 and 1125, now vary between 2110 and 2125 accordingly, after the change.
800905 P E
Parameters
P : The Feature code (3-digit special code)
106
DS200 Programming Guide
107
DS200 Programming Guide
Notes
The access codes of the features can be modified through this program when one wishes to
make use of the features through shorter codes, or in cases when the entered numbering
plan makes the feature codes too long.
If the entered access code is of 8 digits, then dial tone or the invalid operation tone is
received after entering the last digit. If dial tone is received, then the entered code does not
coincide with any other code and the operation has been accomplished. On the other hand, if
108
DS200 Programming Guide
the invalid operation tone is received, then that means the code coincides with other codes,
thus the operation has not been accomplished.
If the entered access code is of less than 8 digits, then the operation should be terminated
with * key. In that case, either dial tone or the invalid operation tone is received. For the
invalid operation case, either the coincided code must be replaced by another, or must be
temporarily deleted.
For example: A line is requested by pressing 9 in order to make external call; the code of
that feature is 004. If the code 800904 004 01* is entered, then dialing 01, instead of 9, is
required to access a line. The features that can be modified through the flexible numbering
and their 3-digit special codes are in the table above.
If the Karel digital telephone set is utilized for programming, then the coinciding number will
be displayed, in case of a coincidence.
800906 F E
Parameters
F : The 4-digit physical address of the line the number of which will be
changed.
Notes
1- This program defines a new number for an extension or a line by using its physical
address.
2- This program is useful for entering the correct access code without the need for the
previous access code data, in case access codes of some of the extensions or lines have
been forgotten or confused.
SUMMARY:
Entering a New Numbering Plan (Following Reset):
If you clear the access codes of some non-existing extensions in the system in order to
assign them to the existing extensions, or, in order to utilize the starting figures of them
(eg. utilizing 2 in a system without an extension whose number starts with 2120), then
enter Inaccessible next to that extension in the form.
Enter a new numbering plan through the programs 800903, 800904, and 800905. In case
there are coincidences, clear the coinciding access codes temporarily through the code
800903 H.
Check whether the plan has been entered correctly by calling the extensions and
accessing the features.
109
DS200 Programming Guide
Transfer the Access Table to the non-volatile memory through the program 800000.
Keep the Access Table form; it will be necessary in the future, when you would like to
make modifications.
If the numbering plan to be entered coincides with the current plan too much, then clear
the extension and line access codes through 800900 or load the default values to the
table through 800902.
Enter the new numbering plan through the programs 800903, 800904 and 800905. In case
there are coincidences, clear the coinciding access codes temporarily through the code
800903 H.
Check whether the plan has been entered correctly by calling the extensions and
accessing the features.
Transfer the Access Table to the non-volatile memory through the program 800000.
Keep the Access Table form; it will be necessary in the future, when you would like to
make modifications.
Make the modifications, which have been recorded into the form, through the programs
800903, 800904 and 800905. In case there are coincidences, clear the coinciding access
codes temporarily through the code 800903 H.
Check whether the plan has been entered correctly by calling the extensions and
accessing the features.
Transfer the Access Table to the non-volatile memory through the program 800000.
Keep the Access Table form; it will be necessary in the future, when you would like to
make modifications.
Dial 744 on the operator phone. That code will re-load the program parameter and the
Access Table from the non-volatile memory. If the problem persists, then make the
necessary corrections on the Flexible Numbering Plan.
110
DS200 Programming Guide
Stopping Alarm:
This program allows stopping the alarm signal.
800701 P
Parameters
P : 1 For PABX systems the alarm when the system powered by
battery is stopped. For rural systems SS7 link alarm is
stopped.
800950 Y P
Parameters
Y : The slot number of the card
Default Value
P = 1 for all cards.
Notes
You can perform operations related to the cards through that code without powering the
system off when you want to add or remove a card while the system is operating. Only the
extension or line modules are turned on and off by that action, whereas the UTIL200 and
CPU200 cards strictly must not be removed from the system in any case while the system is
operating.
111
DS200 Programming Guide
The slot numbers corresponding to racks are in the table below: (The values that the
parameter Y can take on.)
6th rack
94
80
81
82
83
84
85
86
87
88
89
90
91
92
93
THE SECOND CABINET
5th rack
78
64
65
66
67
68
69
70
71
72
73
74
75
76
77
4th rack
62
48
49
50
51
52
53
54
55
56
57
58
59
60
61
3rd rack
46
32
33
34
35
36
37
38
39
40
41
42
43
44
45
THE FIRST CABINET
2nd rack
30
16
17
18
19
20
21
22
23
24
25
26
27
28
29
1st rack
14
00
01
02
03
04
05
06
07
08
09
10
11
12
13
UTIL200 cards
EX200 or EVM200 cards
CPU200 card (No slot number)
CC Enable (No slot number)
The slot numbers of the UTIL200 cards have been presented, however the UTIL200 cards
cannot be turned on or off through that program.
By using that program, a card can easily be removed from the system by being powered off.
Likewise, when a new card is added to the system, the card can be powered by that program.
800951 P
Parameters
P : 0 All parameters, except for call records, are cleared.
Notes
When this code is dialed, the parameters in the non-volatile memory are deleted according
to the program entry. Then, in order to provide normal system operation, either the system
tables should be reset or a parameter file which has previously been created for an
exchange with the same configuration should be loaded through the ADMIN200 PC interface.
Card Configuration:
800952 Y P
Parameters
Y : PRI ISDN / R2 card Slot number
Notes
1- The entry of that program must be terminated with the * key.
3- If a problem with LEDs are observed when the card is placed into the slot, then that could
be solved by adjusting the NT/TE mode parameter of the program.
Communication Query:
This program transfers the data, related to the communication among the CPU200
Communication Controller and the other peripheral units, to the DS_DATA.BIN file.
800960 P
Parameters
P : 0 The communication parameters data do not flow into the
DS_DATA.BIN file.
113
DS200 Programming Guide
: 7 Y Q
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program. When
the admin software is run, the DS_DATA.BIN file is automatically created by the software.
2- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
3- Since the content of the file DS_DATA.BIN is encrypted, the data in that file cannot be
deciphered by anyone except the specialized personnel. The proper check of the file will
be performed by Karel.
4- When the system is turned on, the errors (if any) in EEPROM tables are recorded to
DS_DATA.BIN file.
114
DS200 Programming Guide
Notes
The inquired data is saved into the DS_DATA.BIN file.
800970 Y 00
Parameter
Y : The number of the slot where the card is located.
Notes
1- Please see the Card Turn On/Off program, for the card slot numbers corresponding to
racks.
2- The code 800960 3 should have been entered in order to make use of that program.
3- The ADMIN200 PC interface must be operational in order to utilize that program.
4- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
CC Version Query:
This program transfers the software version data of the CPU200 Communication Controller
to the DS_DATA.BIN file.
800971 00
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program.
2- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
800972 00
115
DS200 Programming Guide
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program.
2- All extension cards are inquired by that program.
3- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
800973 00
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program.
2- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
VoIP, TWT, PRI ISDN, BRI ISDN And R2 Line Card Version
Query:
This program transfers the software version data of the VoIP, TWT, PRI ISDN, BRI ISDN and
R2 cards to the DS_DATA.BIN file.
800974 00
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program.
2- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
800975 00
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program.
116
DS200 Programming Guide
2- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
800976 A
Parameter
A : The access code of the extension
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program.
2- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
800977 00
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program.
2- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
800978 P
Parameter
P : 0 The Call Back feature table
117
DS200 Programming Guide
: 4 EVM200 table
Notes
1- The ADMIN200 PC interface must be operational in order to utilize that program.
2- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
Parameters
Y : PRI ISDN / R2 card slot number
Default Value
P=0 for all PRI ISDN/R2 cards.
Notes
1- One of the cards which are enabled as a source for the system clock by this program, is
activated as the external clock source for the system if the external clock utilization is
activated by 800980 coded program. If for any reason the card fails to receive the external
clock, another card is activated by the system automatically.
2- Especially for data applications like video transmission, one of the cards in the first rack
of the system must be enabled as the clock source. Additionally 800980 coded program
must be used to activate the external clock source for the system.
External Clock:
If it is required to synchronize the system with an external device (this is generally required
for data applications like videoconference), then with this program the system must be set to
use the external clock.
800980 P
Parameters
P : 0 System uses its internal clock.
118
DS200 Programming Guide
Default Value
P=0
Notes
1- If P=1 but the system cannot detect an external clock then it goes on using its internal
clock.
2- If the system is set to use external clock source with this program then any one of the
PRI ISDN / R2 cards which are enabled as the external clock source by 800979 coded
program, is selected as the external clock source by the system automatically and the
system synchronizes itself to that clock.
3- Especially useful for video conference and similar data transfer applications together
with 800979 coded program.
Line Monitoring:
Thanks to this program, a call being made on a line can be monitored and checked to see if
there is any problem.
800989 Y P
Parameter
Y : The slot number of the related card
Notes
1- Do not hang up after having entered the program code. The conversation on the related
line will be connected to your phone. In that case you can listen to both parties, but they
cannot hear you.
2- The program is automatically deactivated when the phone through which the
programming has been done is hung up.
800990
Notes
1- When this code is dialed, the system restarts without being powered off and with all the
modified and saved parameters being preserved. This code is especially useful when
there is a confusion about the parameters which have been saved into the system
memory. It is also useful for inquiries about cases such as inaccessibility of a line as the
result of suspension.
2- The ADMIN200 PC interface must be operational in order to utilize that program.
119
DS200 Programming Guide
3- Prior to the entry of that code, the current DS_DATA.BIN file belonging to the ADMIN200
PC interface should be renamed. Then the code should be entered and the DS_DATA.BIN
file should be copied to another location when the recording is over, in order to be sent to
Karel. Finally, the previously renamed file should be renamed as DS_DATA.BIN again.
120
DS200 Programming Guide
121
DS200 Programming Guide
e) If the technician enters a program or feature code incorrectly, then s/he receives the
error tone. In such a case, s/he can refresh the discontinuous dial tone by pressing the
* key.
f) If the numbering plan of the system, which is remotely programmed, has been previously
modified, then the technician must use the new numbering plan.
A technician can use all of the program codes that are available in this guide. Additionally,
s/he can activate the user and operator features below during the remote programming:
1. The night mode
2. Time setting
3. Date setting
4. Common pool entry
5. Parameter download
6. Call Listing
7. All Call Listing / Stop Listing
8. Total Cost Listing
9. Call Record Clear
10. Remote Follow Me
11. Line Access
If no number is dialed within 15 seconds, after another line is accessed, then the line,
which has already been accessed, is automatically released.
The external call, which the technician will make, can take at most 50 seconds.
12. Calling an extension:
While using this facility, if the extension of the system hangs up, the line is not released
but the technician receives the special dial tone for remote programming, so that s/he
can continue with the remote programming of the system.
122
ADMIN200
USERS GUIDE
The products may have some differences from the functionality written in this guide
according to the hardware revision or software version.
TABLE OF CONTENTS
4) Other Files: These files are stored under the folders which automatically formed under
the directory of ADMIN200 program after the operations under Reports menu.
1
DS200 ADMIN200 Users Guide
- Errors folder: Contains the ddmmyyyy.txt file with error messages of lines, for R&D
purposes. (The file name is the date of the Monday of current week. e.g.0812003.txt.)
- Report folder: Explained in Trunks option of Reports menu.
- Trunklog folder: Explained in Trunks option of Reports menu.
The ADMIN200 program is presented within a diskette that comes with each DS200, DS200S
and DS200M system. The cable that will be used for the exchange-computer connection is
provided as well, beside that diskette.
The ADMIN200 program has been designed to work on Windows 9x, Windows NT, Windows
2000 and Windows XP operating systems, and it has a structure that would allow it to be used
even by ones who have merely basic computer knowledge, due to its friendly GUI.
The DS200, DS200S and DS200M exchanges can be programmed through the first analog
extension phone, which has been determined as the Operator (Starting extension number is
1110.) by dialing the codes specified for programming. However, programming medium and
large-scale exchanges such as DS200, DS200S and DS200M in that way may take quite long
time and become cumbersome. Therefore, utilizing the ADMIN200 to program the exchange
would provide time efficiency as well as facilitation and control of the programming through
visual means.
Through the ADMIN200 program, it is possible to do the entire programming that would be
coded over the Operator phone. Besides, some features that can be activated by all users
through their own phones (e.g. Follow Me) and some operator-specific features can be
activated (e.g. the Night Mode). Some programming related to the system parameters, which
could not be entered through phone, can also be accomplished through ADMIN200.
The entire program functions are explained in the chapter How to Use the ADMIN200
Program in this guide. Since some of the features that can be controlled by ADMIN200 can
be accomplished by dialing through phones as well, detailed information about those
features are included in other guides, according to the structure of the codes; thus, this
guide shall not mention such details, but shall reference to related guides, instead. Detailed
information about the settings that can be done only by ADMIN200 has been presented in the
final chapter of this guide.
2
DS200 ADMIN200 Users Guide
3
DS200 ADMIN200 Users Guide
4
DS200 ADMIN200 Users Guide
There are three sets of fundamental information about the configuration of the system on
this screen. As seen in the taskbar at the bottom of the screen, that information are the main
software version of the exchange, the number of extensions and lines of the exchange. In
addition to that, again in the taskbar, icons (leftmost) displaying whether the system is in the
Night Mode or the Day Mode have been employed.
At the center right in the main screen, the version number of the software being used is
displayed in red characters.
Menu options that would be functional for program utilization can be seen in menu bar.
Those menus are as follows, from left to right in order:
File
Non-Volatile Memory
Configuration
System Parameters
Services
Tables
5
DS200 ADMIN200 Users Guide
ACD
LCR-ARS
Reports
Security
Accessing the entire operations related to the ADMIN200 program is achieved over those
menus. When any menu is selected, a menu window displaying options_if there is any_ within
the menu appears. There are two types of options. One type of option directly initiates an
operation and such menu items have no sign next to their titles. On the other hand, some
menu items do not carry out any operation, but yield to another submenu with related sub-
options. This type of options have a sign right to their titles.
All of these menus are reviewed below one by one. There are a number of general-purpose
buttons used in all menus. Since their functions are the same for all menu options, the
explanations below apply for all menus; hence, similar explanations shall not be repeated for
each menu.
Close button: When this button is clicked, modifications made on the related menu option
are cancelled, the menu option is closed and one proceeds back to the higher-level menu.
Program button: In order to activate this button, value of at least one of the parameters of
the related menu should be modified. Upon clicking that button when it is active, the entire
modifications that have already been made are uploaded to the exchange.
Program All button: This button is valid only if the same type of programming would apply
for more than one window, and when it is clicked, all parameters in the entire windows are
transferred to the exchange.
Update button: When this button is clicked, the most up-to-date parameter values of the
related menu option are reloaded from the exchange and displayed on the screen. Especially
if programming is simultaneously done through the system supervisor phone while
ADMIN200 software is being employed, then that button can be useful to view the latest
forms of the programs entered through the phone, as well.
OK button: If this button clicked after the sub-parameters related to a menu option have
been programmed, then the modifications are accepted and one proceeds back to the upper
level menu; however, those parameters are not uploaded to the exchange yet. One needs to
click the button Program, in order to accomplish that.
Cancel button: If this button clicked after the sub-parameters related to a menu option
have been programmed, then the modifications are cancelled, and then one proceeds back to
the upper level menu.
File button: This button presents two sub-options.
Load: A related parameter file that has been previously saved into the computer is loaded
and displayed on the screen through this option. However, those parameters are not
transferred to the exchange from the file directly, that operation is rather done after the
loading upon clicking the Program button.
Save: The parameters displayed on the screen are saved to a file through this option.
Reset button: The parameters displayed on the screen are reset to their factory defaults
through this button. However, they are not uploaded to the exchange until the Program
button is clicked.
Delete button: Upon clicking this button, value of the related parameter is deleted and the
window is set for another entry.
^Button: List of the menu options related to the current menu is displayed upon clicking
this button and one may proceed to another menu option.
6
DS200 ADMIN200 Users Guide
Button: A summarized view can be obtained through this button, if a window contains too
many parameters.
?Button: A specific parameter can be directly located through this button, if a window
contains too many parameters.
List button: A list of specific features can be viewed through this button.
Contents of all menus are explained below, with respect to the order above.
PC > PABX option is employed for transferring the exchange parameters, which have
previously been saved into PC, to the PABX. Transferring can be performed for the entire
parameters as well as for some specific parameter groups. Those parameter groups appear
on the screen when the PC > PABX option is selected. Those are:
Parameter File: The entire system, extension and line parameters. The file name
extension is DS2.
Common Pool File: The numbers that have been recorded into the common
memory of the system with a capacity of 1000 entries. The file name extension is
CPF.
Private Pool File: The collection of private memory numbers that is created by
each user for personal usage. The file name extension is PPF.
Account Code Table File: The table in which the customers who can make calls
with password and restriction. The file name extension is MST.
LCR-ARS File: The parameters that would provide selection of the least-cost
route automatically. The file name extension is ASR.
All: All of the parameters above. This option functions for all groups as if the
entire parameters above have been selected one by one in a row.
When one of those options is selected, name of the file to be loaded is prompted. After a valid
file name has been selected, the parameter values in the selected file are written into the
volatile memory of the system and the system starts to operate with those values. In order to
preserve those parameters in case of a power failure, the parameters should be saved in the
non-volatile memory through the option Write in the Memory in the Non-Volatile Memory
menu.
Through the PABX > PC option, the parameter values that are active on the PABX are
transferred from the PABX to the PC so that their back up is provided. Either the entire
parameters can be transferred from the PABX to the PC in a single time or specific
parameter groups can be transferred independently. Those parameter groups appear on the
screen when the PABX > PC option is selected. Those are:
Parameter File: The entire system, extension and line parameters. The file name
extension is DS2.
7
DS200 ADMIN200 Users Guide
Common Pool File: The numbers that have been recorded into the common
memory of the system with a capacity of 1000 entries. The file name extension is
CPF.
Private Pool File: The collection of private memory numbers that is created by
each user for personal usage. The file name extension is PPF.
Account Code Table File: The table in which the customers who can make calls
with password and restriction. The file name extension is MST.
LCR-ARS File: The parameters that would provide selection of the least-cost
route automatically. The file name extension is ASR.
All: All of the parameters above. This option functions for all groups as if the
entire parameters above have been selected one by one in a row.
When one of those options is selected, name of the file in which the parameters will be saved
is prompted and then the parameters are written into the file that has been created in the
entered name.
The PRINT option allows taking printouts of specific parameters from different
environments through a printer. The sub-options for that option are:
File: This option is used for printing the contents of the file in which the
parameters that have previously been transferred to computer environment have
been saved. Name of the file containing the parameters to be printed is prompted
upon selecting this option. The parameters are printed out upon entering a valid
file name.
Settings: The parameter values that are active on the exchange are printed out.
Special: Printouts of some of the exchange data are taken optionally. The window
below appears after selecting this option and the related parameters are printed
out by marking desired items.
8
DS200 ADMIN200 Users Guide
The READ FROM THE MEMORY option transfers parameter values that are in the
non-volatile memory of the exchange simultaneously both to the volatile memory and to the
ADMIN200 program automatically. Hence, it is possible to view and modify the parameters
directly, which are in the non-volatile memory.
The WRITE IN THE MEMORY option allows writing of the parameters, which have been
modified by ADMIN200 and which have already been saved in the volatile memory, into the
non-volatile memory in order to preserve them in case of a power failure. This option should
definitely be used following completion of the programming by ADMIN200. Otherwise, there
might occur undesired loss of parameter values and thus operational malfunctions. Once the
operation is over, the system displays the message The operation has successfully been
accomplished.
The RESET THE MEMORY option resets the entire parameter values in the non-volatile
memory to their factory default values. In that case, either the exchange should be re-
programmed from the beginning, or a previously saved parameter file should be loaded. That
option is especially useful if there have been some undesired changes in the parameter
values, which are active on the exchange, or if the exchange is not functioning satisfactorily.
The exchange could be re-programmed or another parameter file could be loaded after
employing that option.
The window below appears when the PABX Configuration option is selected:
9
DS200 ADMIN200 Users Guide
The characteristics of a card in any slot of any rack can be viewed in that window. One can
choose a rack through the selection bar in the lower section of the window and view a card
through a color scheme. The legend for that color scheme is continuously displayed on the
right-hand side.
Besides, the numbering plan related to a card can also be viewed by placing the mouse
cursor on the card and keeping the left mouse button pressed. As long as the button is kept
being pressed, the list of numbers that have been assigned to the lines on the card can be
viewed.
10
DS200 ADMIN200 Users Guide
As can be seen in the window view above, not only the line numbers, but also information
such as the row of the card in the rack and type of the card can be obtained.
Again, in this window, when the cursor is placed on a card and right mouse button is
pressed, three options about the card are presented to the user. Those options are:
Turn on the card: The line and extension cards in the exchange can be put on and off line
through software control. Any card that has been put off line like this can be put on line again
through that option.
Turn off the card: Any line or extension card can be put off line through this option. By this
way, the card can be disconnected and connected again while the exchange is still working
normally.
Version query: The software version of the card can be sent to the DS_DATA.BIN file through
this option.
11
DS200 ADMIN200 Users Guide
Parameters related to the system in general are contained in five groups in the System
Parameters menu. The guides that contain detailed information about the features related to
those parameters are referenced to in the table below (PG : Programming Guide, UG: Users
Guide, AG: ADMIN200 Users Guide).
Group No Parameter Guide
1 Night Mode UG
1 Programming AG
1 Data -
1 Music PG
1 ACD PG
1 External Clock PG
1 Incoming Call Filter No AG
1 Outgoing Call Filter No AG
1 Operator No AG
1 System Supervisor No PG
2 Follow Me Busy for external calls? PG
2 Follow Me Busy for internal calls? PG
2 Follow Me No Answer for external calls? PG
2 Follow Me No Answer for internal calls? PG
2 Automatic Hold Time PG
12
DS200 ADMIN200 Users Guide
13
DS200 ADMIN200 Users Guide
This menu is used for changing the service access codes of the features on the exchange
used by extensions or the operator. Each service has an access code and a service code. The
service code and access code list of the services contained in the software of the
exchange can be retrieved by clicking the button List.
The access code of a service code from that list can be changed by entering another code in
the New value field and clicking the Program button. However, if the new value coincides
with an existing code on the exchange, no programming can take place and the user receives
an error message. In that case, another code that would not coincide should be entered.
In order to view the list mentioned above properly, the file ADMIN200.EXE and the file
SERVICES.TXT, which has come together with that file, must be in the same folder. If,
somehow, they are not in the same folder, then the list is retrieved again, but the names of
the services are displayed as ?. Except this fact, no problem occurs in operations of either
the program or the exchange.
14
DS200 ADMIN200 Users Guide
The ACCESS TABLE option is one of the most comprehensive options of the ADMIN200
program. Upon selecting it, the entire extensions and lines of the exchange are listed
according to the order they have been located on the exchange. There are two essential
elements in the list:
1. The physical address,
2. The access code.
The physical address is an address scheme, which the users are not aware of, used by the
exchange in order to locate extensions and lines. Users can access a line by dialing access
codes only and they never use the physical address. The list appears as below:
Apparently, the physical addresses starts from 0 at the first extension of the first analog
extension card that is installed in the first slot of the first rack and they are incremented by
one for all lines. If there are empty slots on the exchange, then physical addresses are
assigned to those slots, too, but those empty slots do not appear in the list. By this way,
display for occupied slots is provided only.
Different types of lines that are present in that list have been indicated by a color scheme.
Although this color scheme is the same as the one displayed in the window reached over the
Configuration Menu, it can be viewed in that window as well, upon wish, in order to facilitate
the interpretation of the view. The color scheme is displayed by placing the mouse cursor on
15
DS200 ADMIN200 Users Guide
the button at the upper right corner of the window and keeping the left mouse button
pressed.
That list appears as below:
The main purpose of the list seen in this window is providing means to access the entire lines
one by one and making necessary modifications, as well as informing the user about the
overall configuration. For that purpose, the mouse cursor is placed on the physical address
of the related line and the right mouse button is pressed. There are four options in the menu
that appears afterwards:
1) Parameters,
2) ARS Access Authorization Level,
3) Program,
4) Delete.
Parameters: When this option is selected, different parameter groups are presented to the
user according to the characteristics of the line for each line type. Those are inspected in
detail below:
16
DS200 ADMIN200 Users Guide
Parameters related to that type of lines constitute 6 groups. The parameters in those groups
and list of the guides, in which details about them can be found, have been given below:
Group No Parameter Guide
1 State of the Telephone UG
1 Do Not Disturb UG
1 Executive Secretary Mode UG
1 DISA PG
1 PBX Distribution PG
1 #, * Keys PG
1 Hook Switch PG
1 CRL Port Filter PG
1 Hotel Room Access Permission PG
1 Extension Type (Normal/Hotel Room) PG
1 Personnel Telephone PG
1 Tone On Busy PG
1 Extension Type (Phone/Fax) PG
1 Fax Server (only for ISDN and digital extensions) PG
17
DS200 ADMIN200 Users Guide
2 Password UG
2 Outgoing Call Timeout (sec) PG
2 Intrusion Authority PG
2 Hot Line PG
2 Hot Line Mode PG
2 Can Hold In Hot Line Mode PG
2 Extension Type PG
2 Pager PG
2 Reminder UG
2 Phone Lock Level UG
3 Common Pool Use AG
3 Line Access Permission AG
3 Parallel Ringing UG
3 External Call Authority Level PG
3 Line Access Group No PG
3 Follow Me UG
3 PBX PG
3 Follow Me No Answer UG
3 Can Activate Follow Me PG
3 Executive Secretary Group PG
3 External ACD can be used PG
3 External ACD connected PG
4 Room Vacancy UG
4 Room Tidiness UG
5 Message Box PG
5 Temporary Absent Message UG
5 Permanent Absent Message UG
5 Reminder with Message UG
5 Permanent Reminder with Message UG
5 System Messages Language PG
5 Lock Message UG
5 Access to Message Box PG
5 Voice Message PG
6 Call Pick-Up Permission PG
6 Incoming Calls Can Be Picked-up PG
6 Line Calls Can Be Dropped PG
18
DS200 ADMIN200 Users Guide
Parameters related to that type of lines constitute 5 groups. The parameters in those groups
and list of the guides, in which details about them can be found, have been given below:
Group No Parameter Guide
1 Authorization Check PG
19
DS200 ADMIN200 Users Guide
1 By 9 PG
1 Dial PG
1 State PG
1 TX Gain PG
1 RX Gain PG
1 Metering Pulse Price PG
1 Guest Charge Pulse Price PG
1 Error AG
1 Application PG
1 Line-Line Connection Time-out PG
1 Usage PG
2 In Service for Extension Groups PG
2 Ringing Extension No PG
2 PBX PG
3 Remote Line Access Time-out PG
4 Greeting Menu Number PG
4 Busy Menu Number PG
4 No Answer Menu Number PG
4 Night Greeting Menu Number PG
4 DISA Remote Line PG
4 After Error DISA Line PG
4 No Answer Menu (Nt) AG
4 Busy Menu (Nt) AG
5 Check Dialtone PG
5 Before Sending Numbers PG
5 Special line PG
5 Dial Type After Connection PG
The features with group numbers 2 may be programmed to take different parameters for the
Day and the Night modes. Therefore, the mode of the programming should be selected at the
top of the window and then the modifications should be done accordingly.
When any parameter in any group is modified, the Program button becomes active and
when it is clicked, the modifications are uploaded to the exchange.
20
DS200 ADMIN200 Users Guide
For the PRI ISDN, R2, BRI ISDN, TWT and VoIP lines:
Parameters related to that type of lines constitute three groups. The parameters in those
groups and list of the guides, in which details about them can be found, have been given
below:
Group No Parameter Guide
1 Authorization Check PG
1 By 9 PG
1 State PG
1 Metering Pulse Price PG
1 Guest Charge Pulse Price PG
1 Error AG
1 Line-Line Connection Time-out PG
1 TX Gain (1) PG
1 RX Gain (1) PG
1 Usage (2) PG
1 EAC Table (3) PG
2 In Service for Extension Groups PG
2 PBX PG
3 Remote Line Access Time-out PG
21
DS200 ADMIN200 Users Guide
The features with group numbers 2 may be programmed to take different parameters for the
Day and the Night modes. Therefore, the mode of the programming should be selected at the
top of the window and then the modifications should be done accordingly.
When any parameter in any group is modified, the Program button becomes active and
when it is clicked, the modifications are uploaded to the exchange.
(1)
These fields are available only for TWT lines.
(2)
This field is not selectable for VoIP and TWT lines.
(3)
EAC Table is a quite important table for PRI ISDN, BRI ISDN and R2 lines. (This field does
not appear on the screen for TWT and VoIP lines.) In that table, according to the numbering
plan obtained from CO, specific numbers ring at specific extensions through corresponding
programming upon wish. Besides, it can also be determined through programming, provided
that there is EVM200 card on the exchange, whether a line will be answered by ACD and if it
that is the case, the menus to be activated will be determined, too. That table can be viewed
in two ways on the screen. The first of them is as can be seen below:
22
DS200 ADMIN200 Users Guide
23
DS200 ADMIN200 Users Guide
The complete number is entered in the field Tel No, for BRI ISDN lines and only the DDI
digits (last 3 digits of the number) for the PRI ISDN or R2 lines. Then the forwarding for the
entered number is done to the extension whose number has been entered in the Access code
field.
The Access code displays the extension at which the line with the number in the Tel No
field will ring. The access codes of the related extensions should be entered in that field.
The Type field is employed for determining the line with the defined Tel No as normal, DISA
or a line to be answered by ACD.
The other fields are employed for determining the DID line and ACD features.
The window displaying the main list can be extended to display the ACD menu parameters as
well, upon wish. The sign , which is at the upper right side of the window, should be
clicked for that.
When any modification in that table is made, the Program button becomes active and when
it is clicked, the modifications are uploaded to the exchange.
Moreover, there is a File button in that window, too. The current table can be saved in a file
or a saved table can be loaded from a file by making use of that button. When one of those
options is selected, a file name with the extension AET is prompted and the desired operation
is accomplished through the selected file name.
Another button that takes place in that window is the button ?. The Access Code is
prompted upon clicking that button. An extension number entered in that field is searched in
the table, and if that number has previously been recorded to the table, then the related
table line is displayed.
24
DS200 ADMIN200 Users Guide
Parameters related to that type of lines constitute 5 groups. The parameters in those groups
and list of the guides, in which details about them can be found, have been given below:
Group No Parameter Guide
1 Dial PG
1 Status PG
1 TX Gain PG
1 RX Gain PG
1 Line-Line Connection Time-out PG
2 PBX PG
3 Remote Line Access Time-out PG
3 E&M Tone Reception PG
3 E&M Tone PG
3 Connect to E&M operator PG
The features with group numbers 2 may be programmed to take different parameters for the
Day and the Night modes. Therefore, the mode of the programming should be selected at the
top of the window and then the modifications should be done accordingly.
When any parameter in any group is modified, the Program button becomes active and
when it is clicked, the modifications are uploaded to the exchange.
The ARS Access Authorization Level option presents different parameters for extensions
and lines. For the extensions, The ARS system utilization authorization levels for the Day and
25
DS200 ADMIN200 Users Guide
the Night Services for the related extensions are displayed and modified, upon wish. For the
lines, on the other hand, Access Authorization Levels are displayed and modified, upon wish.
The ARS parameters cannot be programmed through phone. Therefore, the details about
that topic have been presented at the final chapter of this guide.
The Program option is employed for changing the access code of the line. The window below
appears upon selecting this option. Here, the new access code for that line should be entered
in the field Starting and then the Program button should be clicked.
No modification can be done in the Range (As Port No) field in this window.
The Delete button deletes the access code of the line. If the Program button is clicked,
while the access code of a line has already been deleted, then that line appears to be vacant
in the access table and it cannot be accessed.
On the other hand, if the number of the line is changed and then the Program button is
clicked, then the new value is uploaded to the exchange. However, if the new code coincides
with an already existing code, then the program will warn the user by an error message and
require another code that would not cause a conflict.
The Delete option deletes the access code of the related line.
There are general-purpose buttons in the Access Tables window. They are located at the
bottom of the screen.
The Close button closes the window.
The data related to the table can be retrieved from the exchange by making use of the
Update button. By this way, if there are problems that have already occurred in the table,
then they will automatically be eliminated.
26
DS200 ADMIN200 Users Guide
The access codes of lines that are in a specific physical address range of the exchange can
be change altogether by making use of the Program button.
The physical address of the first line to be programmed is entered in the Starting field in
the Range section, and the physical address of the last line is entered in the Ending field.
The access code that will be assigned to the first physical address is entered as the Starting
value and the increment value to be used for increasing the access codes is entered in the
Increment field. Increments of 1, 5 or 10 can be chosen in that field.
The changes made in the Access Table are cleared and the table is reset to factory default
access code values upon clicking the Reset button. That button does not change the settings
for extensions and lines; it rather resets the access codes to their factory default values only.
Lines, which are normally listed according to their physical addresses, are displayed with
respect to their access codes in the Access Table by pressing the button. However, no
operation can be done on the lines displayed in that view.
The Access Code is prompted upon clicking the ? button. If the entered access code
exists in the system, then it is located in the list and the line is directly displayed on the
screen.
The TOLL RESTRICTION TABLE option displays and allows modifications of the fields
of the Line Restricted Prefix Table (see PG), which consists of the line numbers that the
extensions are not allowed to dial according to their authorization levels, and the Line
Permitted Prefix Table (see PG), which consists of the numbers that are allowed to be dialed
by the extensions beyond their authorization levels.
27
DS200 ADMIN200 Users Guide
28
DS200 ADMIN200 Users Guide
The Program button should be clicked for the modifications or additions to take effect. The
changes can be saved to a file or an existing file can be loaded by clicking the File button. A
file name will be prompted in either case. The necessary operation will be accomplished
according to the entered file name.
The Private option lists 10 private pool numbers of the exchange, which are specific to the
related extension and changes can be made on each entry, upon wish. In order to list the
private pool numbers of a specific extension, the corresponding number of the related
29
DS200 ADMIN200 Users Guide
extension is selected in the Access Code field. Later, in order to make changes on one of the
listed records, click the right mouse button on a number in the No column and then select
the Change option. If a delay period is required between two digits, then entering a comma
between the related digits in the Number field allows the exchange to wait during the
processing of those digits.
The Program button should be clicked for the modifications or additions to take effect. The
changes can be saved to a file or an existing file can be loaded by clicking the File button. A
file name will be prompted in either case. The necessary operation will be accomplished
according to the entered file name.
The PBX GROUPS option is used for forming PBX groups for extensions and lines. The
windows for extensions and lines sub-options and the process of forming groups are the
same. Therefore forming PBX groups of extension is explained in the following sections. Line
PBX groups can be formed using the similar methods.
When extension option is selected, the following window appears:
After Day or Night mode is selected in the field on the top of the window, the desired
extensions should be selected by the mouse from the list at the right side of the window.
When an empty row is selected and is pressed, the PBX group is formed. The position of an
extension can be changed by the arrow keys and the extension can be removed from the PBX
group by the x key.
Another point that should be considered is that an extension cannot be a member in more
than one PBX group.
Through the ACCOUNT CODE TABLE option, settings done by the Forced Account
Code User and the related programs are displayed and accomplished. The table below is
reached through that option:
30
DS200 ADMIN200 Users Guide
In this table, those can be entered: guest codes in the range 0..999, parameters determining
the activation statuses for password, line authorization level and pulse price check for the
related guest, as well as the amount of customer charge pulse price. The table below is
reached after clicking on the related line with the right mouse button:
After adjusting the necessary parameters for the related guest code in this window, the
record entry is completed by clicking the OK button. The R button next to the password
field in this window can be used for allowing the computer to assign a random password
automatically. The data is uploaded to the exchange by clicking the Program button that is
in the lower section of the main table, after the settings for the related guest code are done.
31
DS200 ADMIN200 Users Guide
Another button located in the Guest Codes Table is the Close button. The window is closed
by this button. The Update button is used for making sure that the most current form of the
table is being displayed. The File button, on the other hand, is used for saving the changes
to a file or retrieving a table previously saved in a file. A file name will be prompted in either
case and the necessary operation will be accomplished according to the entered file name.
The user is prompted to enter a guest number when the ? button is clicked. The
corresponding line in which the information about the related guest is displayed when the
number has been entered.
Through the FIRST DIGITS TABLE option, the number of digits for the dialed numbers
on external lines can be determined. The following window appears after selecting this
option.
If the number of digits for numbers starting with a specific digits is to be changed, the box
under the desired digits is left clicked and the desired value is entered.
PHONE LOCK LEVELS option is used for defining levels for extensions so that they can
use these levels to lock their telephones for different types of calls.
After right clicking on a box and entering a value, a locked number for that row can be
defined. When a box is right clicked, two options Delete and Delete All appear. Delete
button clears the value in that box whereas Delete All clears all of the boxes on that row.
The GPBX ACCOUNTS option is used for defining metering pulse accounts for
extensions and lines to be used in GPBX Mode. The windows for extensions and lines sub-
options and the process of forming groups are the same. Therefore forming accounts for
extensions is explained in the following sections. Line accounts can be formed using the
similar methods.
When extension option is selected, the following window appears:
32
DS200 ADMIN200 Users Guide
This menu is employed only when there is EVM200 Auto-Attendant and Voice Message
module installed on the exchange, for checking the parameters related to that module.
The window below appears when the GENERAL PARAMETERS option is selected:
33
DS200 ADMIN200 Users Guide
Details about the entire parameters seen in the windows with the group titles Parameter
and Message Types can be found in PG.
When any of these parameters is modified, the Program button becomes active and when it
is clicked, the modifications are uploaded to the exchange.
34
DS200 ADMIN200 Users Guide
The window below with 16 groups, for 16 menus that are all the same, appears when the
MENU option is selected:
There are windows above containing the same parameters under the group headings
extending from Menu 0 to Menu 15 for 16 Auto-Attendant Menus. Details about the entire
parameters in those windows can be found in PG.
None of the parameters in this menu can be entered in the exchange through programming
by phone. Hence, details about the LCR-ARS menu have been presented in the final chapter
of this guide.
The window below opens when the CALL FILTERS option is selected:
In this window, the filters that will be applied to the number dialed through the LCR are
defined for every ARS (Automatic Route Selection) line. Those filters defined here will be
used for the Routing Table entries.
In order to enter data in any line in this window, the filter section of the related line is double
clicked with the left mouse button and then the necessary filter value is typed. The elements
that can be used for defining filters have been explained in detail in the next chapter.
The File button is used for saving the changes to a file or retrieving values that has
previously been saved in a file. A file name will be prompted when this button is clicked and
the necessary operation will be accomplished according to the entered file name.
35
DS200 ADMIN200 Users Guide
The LCR-ARS definitions are very comprehensive and all settings must be flawless in order
to make use of the LCR-ARS feature. Therefore, one can proceed through the ^ button to
the other tables related to the other settings.
The window below opens when the ROUTE TABLE option is selected:
This window explains how checks and operations are done according to the numbers dialed
by the extensions for making external calls. When extensions access lines and dial numbers,
the exchange checks those numbers one by one. If those numbers coincide with the ones
that are in the Routing Table, then the exchange takes the actions in the related line of the
table. The extensions are unaware of those operations. Therefore, that feature is called the
Automatic Route Selection.
There are different definitions for the 3 routes mentioned in the table above. Details of the
parameters in that table have been explained in the final chapter of this guide.
The Close button in the Routing Table window is used for closing the window.
The Update button is used for loading the current form of the table that is in the memory of
the exchange.
The Program button becomes active when modifications with any parameter have been
done and those modifications are uploaded to the exchange when the button is clicked.
The File button is used for saving the modifications in a file or retrieving data that have
previously been saved in a file and loading it to the table. A file name is prompted when this
button is clicked. The necessary operation is accomplished according to the entered file
name.
The ^ button is used for proceeding directly to the other tables related with LCR-ARS.
36
DS200 ADMIN200 Users Guide
The window below opens when the ROUTING PLAN TABLE option is selected:
The day and time of usage of the routes defined in the Routing Table are determined by the
parameters that are entered in the Routing Plan Table. In order to enter a value, one should
double click the related field and enter the value. Moreover, it is possible to define 16
different Routing Plan Table through this table. Details about those parameters are in the
final chapter of this guide.
The Close button is used for closing the window.
The Update button provides displays the current form of the table that is in the memory of
the exchange.
The Program All button is used for uploading the entire modifications in different Routing
Plan Tables to the exchange.
The modifications can be saved in a file or data in a file that has previously been created can
be retrieved through the File button. A file name will be prompted when this button is
clicked. The necessary operation is accomplished according to the entered file name.
The ^ button is used for proceeding directly to the other tables related with LCR-ARS.
The window below appears when the LEADING DIGITS TABLE option is selected:
37
DS200 ADMIN200 Users Guide
The routes that the exchange will apply according to the numbers dialed by the extension is
defined in this table. In order to enter a value, one should double click the related field and
enter the value. Details about those parameters in this table are in the final chapter of this
guide.
The Close button is used for closing the window.
The Update button provides displays the current form of the table that is in the memory of
the exchange.
The Program button is used for uploading the entire changes to the exchange.
The modifications can be saved in a file or data in a file that has previously been created can
be retrieved through the File button. A file name will be prompted when this button is
clicked. The necessary operation is accomplished according to the entered file name.
The ^ button is used for proceeding directly to the other tables related with LCR-ARS.
38
DS200 ADMIN200 Users Guide
SETTINGS option can be used for the scheduling of automatic statistics for external lines.
With this option, the following window appears:
Provided that Collect Trunk Data option is marked, statistical information for external lines is
received periodically with intervals specified in Collect period. Next data collection shows the
time that the next statistics will be received automatically. (The clock of the PC on which
ADMIN200 is running is used for this timing.)
The report for automatic statistics can be reached through TRUNKLOG folder in the directory
where ADMIN200 is running. This folder is formed automatically after automatic statistics of
external lines is obtained. The following files are formed under TRUNKLOG folder:
- ddmmyyyy.txt: This file shows the report for the latest statistics. Its name is the date of
the Monday of the current week. (e.g.0812003.txt)
- details.txt: This file also shows the latest statistics. In addition to ddmmyyyy.TXT, the
detailed information is given per access codes of lines.
- backup.txt: The report for previously taken statistics are archived in this file.
TRUNKS option opens a new window with the following two items:
Collect data: Collects the statistical information about the external calls depending on call
status (busy, answered, ect.).
Create report: Obtains the report for the statistics received by Collect data option. With this
option, the following window appears:
39
DS200 ADMIN200 Users Guide
In this window, the range for the desired statistics must be specified. The name of the
system (local name) and the name of the reporter (reporter) can be entered if desired. If
Cancel button is pressed, the window is closed without any operations. When Continue is
pressed, the following window is opened:
In this window, the report file in HTML format is received through Open file in the following
window:
40
DS200 ADMIN200 Users Guide
If desired, this report can also be reached through REPORT folder in the directory where
ADMIN200 is running. This folder is formed after statistics of external lines are obtained
manually. It contains the following files:
- logo.jpg: The image file of the logo that appears on the top right corner of the report.
- trunk.htm: The report file.
41
DS200 ADMIN200 Users Guide
This menu has no sub-selections. When it is selected, the window below opens:
The Security Menu includes password check feature to the ADMIN200 program, according to
the needs of the user. There is no default password for ADMIN200. The user can define two
different passwords for two different functions by this window, upon wish.
The first of them is the password that is defined for Startup. That password can be defined by
entering it twice in the Password and Password Again fields and then clicking the OK
button. If Ask for password at startup. box is marked, in addition to defining that password,
then the user is prompted for a password at startup each time the program runs.
The other password is the one that can be defined for programming. That password can be
defined by entering it twice in the Password and Password Again fields and then clicking
the OK button. If Ask for password at programming. box is marked, in addition to defining
that password, then the user is prompted for a password each time a parameter is modified
and the Program button is clicked. In fact, that password is prompted only for the first
programming request and if the correct password is entered, there will be no other
password request until the program is exited.
Another function of the Security feature is represented in the main window of ADMIN200 with
the icon depicted by a group of keys (see the figure below). If the program will not be used for
a while even though it still runs, or it should keep running for some queries while the user is
away, then this function can be employed in order to prevent unauthorized usage and
modifications. When this icon is clicked, the program is minimized to the Windows
taskbar. The startup password is prompted in order to maximize the program again and if
the entered password is incorrect, then accessing the program will be impossible.
42
DS200 ADMIN200 Users Guide
When the program runs after that addition, one can observe that the entire main window
structure and the structures of the menus, except the Tables menu, have remained
absolutely the same. The EEPROM Tables option is added to the Tables menu. For the
modifications made through that option to take effect, the exchange or the entire cards of the
same type as the one, whose parameters have been changed, must be turned off and on
again.
43
DS200 ADMIN200 Users Guide
When the EEPROM TABLES option is selected, a menu containing options for different
extension and line types appears:
When the Extension option is selected, the contents of the memory element, which is on the
extension cards, are presented as a table in hexadecimal. This table is rather for R&D
purposes; hence making modifications in that table might disrupt operation of the exchange.
In addition to that, a button has been included at the bottom of the window, in order to
interpret and set the parameters more easily in a visual way.
44
DS200 ADMIN200 Users Guide
Two options are presented to the user when the Other button is clicked.
The Cadence Settings option changes the timings of the tones that extensions hear during
the calls they make and the ringing tones of their phones during incoming call requests.
45
DS200 ADMIN200 Users Guide
The first four parameters seen in this window show the valid time intervals of the tones
heard in various cases during calls by handset, and the last five parameters show the valid
time intervals of the ring cadence of phones for various types of incoming calls. Modifications
can be made on those time intervals, upon wish.
The boxes in dark colors are used for determining the time periods in which tones or rings
will be heard (ON), and the boxes in light colors are used for determining the time periods in
which tones or rings will not be heard (OFF). Since the values that can be entered in each box
varies in the range 0.02 and 2.25 seconds, in cases when durations longer than 2.52 seconds
are required, two consecutive boxes can be selected as ON or OFF. Once the necessary
changes are completed, the OK button is clicked and the new timing parameters become
effective from then on for the next extension operations.
Some low level settings related to extensions are done by the Other Settings option. The
window below opens through this option:
46
DS200 ADMIN200 Users Guide
Maximum DP Break duration: If an extension is employing the flash switch of her/his phone
to make hook flash, then the duration of that hook flash must not be short as to be confused
with the DP break signal. Through this parameter, the maximum signal length that the
exchange will detect as the DP break signal is determined. The value of the parameter can
be entered as in the range 5-1250 msec.
Minimum DP Break duration: The minimum duration of the DP break signal is determined
through this parameter to prevent detection of some very short disconnections, which might
occur on the line while an extension is dialing a number, as a DP digit. The value of the
parameter can be entered as in the range 5-1250 msec.
Maximum DP Make duration: This parameter determines the duration of the maximum make
signal that will be created on the line while an extension is dialing DP numbers. The value of
the parameter can be entered as in the range 5-1250 msec.
Minimum DP Break duration: This parameter determines the duration of the minimum make
signal that will be created on the line while an extension is dialing DP numbers. The value of
the parameter can be entered as in the range 5-1250 msec.
If DP phones of extensions are generating out-of-standard signals, then the parameters
related to DP dialing can also be set to detect those signals.
Minimum Inter-digit time-out for DP dialing: This parameter sets the length of the delay
period between two digits dialed consecutively in order to make sure those digits are
detected correctly by the exchange. The value of the parameter can be entered as in the
range 5-1250 msec.
Minimum disconnect duration for on-hook (as flash disabled): This parameter sets the
duration of the period in which an extension must keep the handset on hook in order to
terminate a call (while the extension does not have hook-flash authorization). The value of
the parameter can be entered as in the range 5-1250 msec. That value also determines the
upper limit of the hook flash period, i.e., on hook durations that are shorter than the
determined period are considered as hook flash, and the ones longer than that period are
considered as hanging up.
Tone connection time after going off-hook: This parameter sets the length of the minimum
period in which an extension has to keep the handset off hook for the handset to be detected
by the system as lifted. The value of the parameter can be entered as in the range 5-1250
msec. This parameter can be employed especially to avoid such cases when the hook switch
is turned on and off for very short time intervals unintentionally due to the very own
characteristics of a phone while the extension is lifting the handset, the system may interpret
such intervals as dialed DP digits and disconnect the dial tone.
Minimum off hook duration during ringing to connect the call: In case of a coming call
request, this parameter sets the length of the period in which an extension has to keep the
handset off hook, in order to be detected by the system as answering the call. The value of
the parameter can be entered as in the range 5-1250 msec. This parameter can be employed
especially to avoid the misinterpretation by the system of the cases, when the hook switch is
turned on and off for very short time intervals unintentionally while the extension is lifting
the handset, due to the very own characteristics of a phone, as the call is being answered
and to avoid dropping of the line.
The entire parameters, except the last one, in this window are valid for all extensions,
whereas the last parameter may be extension-specific. However, changes made through this
window will exactly be reflected to the entire analog and rural extension cards.
On the main table in hexadecimal format, the charging method can be programmed only for
Rural Extension cards. The value on 9th column of the 22nd row of this table is used fro this
adjustment (this value is 01 be default). The values and operations of them for this entry are:
47
DS200 ADMIN200 Users Guide
48
DS200 ADMIN200 Users Guide
49
DS200 ADMIN200 Users Guide
Metering pulse frequency upper limit: This parameter sets the upper limit of the frequency
range in order to detect the pulse price signal transmitted from the network to which the
exchange is connected. The value of the parameter can be entered as in the range 100-25000
Hz. The pulse price signal frequency is 12000 Hz for Turkey.
Metering pulse frequency lower limit: This parameter sets the lower limit of the frequency
range in order to detect the pulse price signal transmitted from the network to which the
exchange is connected. The value of the parameter can be entered as in the range 100-25000
Hz. The pulse price signal frequency is 12000 Hz for Turkey.
Minimum metering pulse on duration: This parameter sets the minimum duration of the
pulse price signals to be detected correctly, which are transmitted from the network to
which the exchange is connected. The value of the parameter can be entered as in the range
10-2500 msec.
Minimum metering pulse off duration: This parameter sets the minimum wait time between
two consecutive pulse price signals, which are transmitted from the network to which the
exchange is connected, for the signals to be detected correctly. The value of the parameter
can be entered as in the range 10-2500 msec.
Current detection on line: This parameter controls whether current check will be done on an
analog line. If current check is performed on a line and if the exchange does not detect
current on that line, then the line is taken out of service, so that extensions are prevented to
access such malfunctioning lines.
The entire parameters in that window will be valid for all analog lines.
When one of the E&M and LB Lines options is selected, the contents of the memory element,
which is on the cards of those lines, is presented as a table in hexadecimal. This table is
rather for R&D purposes; hence making modifications in that table might disrupt operation
of the exchange. In addition to that, a button has been included at the bottom of the window,
in order to interpret and set the parameters more easily in a visual way.
The Cadence Settings option is presented to the user when the Other button is clicked.
That option changes the timings of the signals of the tones heard during line access.
The first four parameters seen in this window show the valid time intervals of the tones
heard in various cases during line access, and the last five parameters show the valid time
intervals of the ring cadence of phones for various types of incoming calls. Modifications can
be made on those time intervals, upon wish.
The boxes in dark colors are used for determining the time periods in which tones or rings
will be heard (ON), and the boxes in light colors are used for determining the time periods in
which tones or rings will not be heard (OFF). Since the values that can be entered in each box
varies in the range 0.02 and 2.25 seconds, in cases when durations longer than 2.52 seconds
are required, two consecutive boxes can be selected as ON or OFF. Once the necessary
changes are completed, the OK button is clicked and the new timing parameters become
effective from then on for the next extension operations.
When the PRI ISDN option is selected, the contents of the memory element, which is on the
PRI ISDN cards, are presented as a table in hexadecimal. This table is rather for R&D
purposes; hence making modifications in that table might disrupt operation of the exchange.
In addition to that, a button has been included at the bottom of the window, in order to
interpret and set the parameters more easily in a visual way.
Two options are presented to the user when the Other button is clicked.
The Cadence Settings option changes the timings of the signals of the tones heard during
line access.
50
DS200 ADMIN200 Users Guide
The first four parameters seen in this window show the valid time intervals of the tones
heard in various cases during line access, and the last five parameters show the valid time
intervals of the ring cadence of phones for various types of incoming calls. Modifications can
be made on those time intervals, upon wish.
The boxes in dark colors are used for determining the time periods in which tones or rings
will be heard (ON), and the boxes in light colors are used for determining the time periods in
which tones or rings will not be heard (OFF). Since the values that can be entered in each box
varies in the range 0.02 and 2.25 seconds, in cases when durations longer than 2.52 seconds
are required, two consecutive boxes can be selected as ON or OFF. Once the necessary
changes are completed, the OK button is clicked and the new timing parameters become
effective from then on for the next extension operations.
51
DS200 ADMIN200 Users Guide
52
DS200 ADMIN200 Users Guide
53
DS200 ADMIN200 Users Guide
Through the Language option in this window, the language of some messages that will be
transmitted to ISDN or digital phones is selected between Turkish and English.
54
DS200 ADMIN200 Users Guide
IV. LCR-ARS
LCR (Lease Cost Routing) ARS (Automatic Route Selection) feature is one of the most
superior features of the DS200, DS200S and DS200M exchanges.
Thanks to that feature, the exchange automatically figures out the least costly route
according to the call type the extension wishes to make and establishes the connection
through that route. Hence, that feature provides means to reduce telephone expenses to a
minimum. Meanwhile, the extension makes a normal line call, being unaware of such
automatic routing operations.
The exchanges must be programmed accordingly first, in order to fulfill such automatic
operations. That programming can be realized only by ADMIN200.
Some of the tables used during that programming and parameters used in those tables are
below:
55
DS200 ADMIN200 Users Guide
NO: It is the route number. It can take values in the range 1..32.
FILTER NO: It is the filter number that will be used in the related route line. That filter
number is the parameter that appears as Line in the Call Filters Table.
56
DS200 ADMIN200 Users Guide
TRUNK: If the exchange is supposed to access a specific line according to the number
dialed by an extension, then the access code of the related line is entered in this field.
A.L.: Not only the least costly route, but also the most reliable route can be selected by the
LCR-ARS feature sometimes. That route may be more costly than the other routes; hence,
not all the extensions may be allowed to make use of that route. The ARS access
authorization levels for the extensions are defined for that purpose (Access Tables ARS
Access Authorization Level). The value in the A.M. field displays the minimum necessary ARS
Authorization Access Level for the extensions that can use the route in the indicated
direction. For instance, if there is 7 in this field, the extensions with the ARS access
authorization level 7 or higher can use that route, whereas the level six or lower levels are
not sufficient to use the route.
WT: It determines whether an extension will hear a warning tone from handset in case
somehow there is necessity for the 2nd or 3rd routes to be used. By this way, the extension
knows the line access is not through the most convenient route according to the criteria set
by her/him, but through an alternative route instead.
ROUTE: If the number of the route is also defined in ROUTES.TXT file, this field shows the
route name corresponding to this route line. If the route number is not defined in
ROUTES.TXT, then this field is empty.
STARTING TIME: If the routes to be applied have been determined to differ according to
day and time, then the related time is specified here. There are check boxes next to this
parameter field for the 7 days of the week.
ROUTING NUMBERS FOR DAYS: Route numbers (The No field in the Routing
Table), which are to be used starting from the specified day and time, are entered in the
check boxes for days next to the Starting Time parameter field.
57
DS200 ADMIN200 Users Guide
ROUTE: The route (Routing Table) or the routing plan to be applied is selected when the
defined numbers are dialed.
Before starting with LCR-ARS programming, planning is required considering the entire
parameters in the tables mentioned above. For example:
Suppose a GT20 GSM Gateway device has been connected to the lines 7200 and 7201 of the
DS200 exchange. The line 7200 is connected to the GSM operator with the code 0542 (That
operator supports calls with the codes 0543 and 0546 as well) and the line 7201 is connected
to the GSM operator with the code 0532 (That operator supports calls with the codes 0533
and 0535 as well.)
One does not need to dial the prefix 0542 to call a number beginning with the code 0542 on
the operator 0542.
Likewise, One does not need to dial the prefix 0532 to call a number beginning with the code
0532 on the operator 0532.
The extensions are required to make their GSM calls over the GT02 device. However, if the
entire lines of GT20 are busy during a GSM call, then certain extensions will be enabled to
call through the normal CO line with number 701. The ARS Access Authorization level of the
extensions that will be allowed to make use of the normal line is required to be at least 10. In
that case, the extensions will receive the warning tone.
In the meantime, it is required that other GSM calls starting with 05xx shall be made through
the operator with the code 0542.
In that case, the following should be considered for the planning:
1) Starting digit numbers:
90542, 90543, 90546, 90532, 90533, 90535, 905 else
2) The lines to be used:
For 90542, 90543, 90546, 905 else: 7200,
For 90532, 90533 and 90535: 7201.
3) Ranges in time and day base:
None
4) Filters:
R5 for 90542 and 90532 (In order to discard the entire prefix)
R1 for the others (In order to discard 9 only, which is the line access code)
5) A.L.
0 for the 1st route,
10 for the 2nd route.
6) WT
Let the extensions receive the warning tone for the cases when 2nd route is selected:
Present.
The programming can start after determining all those.
First of all, the ARS filters table is opened and the filters are defined:
58
DS200 ADMIN200 Users Guide
There is no need for a Routing Plan Table, since there is no setting related to date and time.
Finally, the Leading Digit Table is created:
59
DS200 ADMIN200 Users Guide
60
KNEE PROGRAMMING
GUIDE
The products may have some differences from the functionality written in this guide
according to the hardware revision or software version.
TABLE OF CONTENTS
I. INTRODUCTION.................................................................................................... 3
II. INSTALLING AND RUNNING KNEE PROGRAM................................................... 4
III. MAIN WINDOW..................................................................................................... 5
IV. EX200 (4VOIP) APPLICATIONS............................................................................. 6
IV.1. EX200 (4VOIP) APPLICATION................................................................................................. 7
I. INTRODUCTION
KNEE program is the software used for programming LAN Adaptor and EX200 (4VoIP)
modules of DS200 system. This software is included in the CD which is shipped with each
DS200 main-rack and can be used with all EX200 (4VoIP) and LAN Adaptor modules.
3
DS200 KNEE Programming Guide
Once the IP address, which had been previously defined by programming, is entered; KNEE
program searches for this card on LAN. If the card with this IP is found, the main program
window opens.
4
DS200 KNEE Programming Guide
The following options of this window are the same for VoIP and LAN Adaptor cards:
Refresh button refreshes the information about the card on the screen.
Settings button opens the following window with the setting of KNEE program:
Under normal conditions, there is no need to make any adjustments on this window.
Security button can be used to define a password and this password can be used each time
KNEE program is run.
5
DS200 KNEE Programming Guide
The IP settings of the card must first be defined from system supervisors telephone by the
800480 coded program so that KNEE program can recognise EX200 (4 VoIP) card. Because,
KNEE program searches the VoIP card by its IP address.
(Please see programming manual for the details of the 800480 coded program.)
After the LAN connection of the VoIP card is made by a standard network cable, the card can
be reached by KNEE program.
6
DS200 KNEE Programming Guide
For the setting of VoIP card, the shortcut of KNEE program is used. After the target card is
found, the following window appears:
When right-clicked by the mouse on the VoIP card seen on the main window, five options
appear:
7
DS200 KNEE Programming Guide
In addition to the values defined by the 800480 coded program, this window shows the
following information:
DS200 No: Used for monitoring purposes. It does not have any functionality in normal
operation.
Gatekeeper: This box should be marked if a Gatekeeper is available on VoIP cards LAN
or WAN.
Gatekeeper discover: This box is used only for design phase and must be unmarked
during normal operation.
Gatekeeper 1 IP-Gatekeeper 2 IP: Gatekeepers IP address should be entered as
Gatekeeper 1 IP, and alternative Gatekeepers IP address should be entered as
Gatekeeper 2 IP. If only one Gatekeeper is available, the same IP address should be
entered for these fields.
8
DS200 KNEE Programming Guide
Address Table
Example:
Suppose there are two DS200 systems, each with one VoIP card with the following
numbering and IP plans:
System A:
Extension access codes :1000 1999
VoIP cards IP address : 192.168.2.35
Access codes of VoIP cards lines :1678, 1679, 1680, 1681
System B:
Extension access codes: 2000 2999
VoIP cards IP address: 192.168.4.24
Access codes of VoIP cards lines: 2346, 2347, 2348, 2349
9
DS200 KNEE Programming Guide
In this case, there two alternatives for filling out address table on system A:
a) When Gatekeeper is used:
As seen here, the destination is selected as Gatekeeper for one of the rows and Gateway
for the other row.
Once VoIP card is put into operation, it should tell the Gatekeeper that the system it belongs
has extension numbers starting with 1 (registration). For this reason, VoIP card reaches
the Gatekeeper through the specified IP address and informs Gatekeeper both about itself
and the incoming calls for the system through VoIP card start with 1.
Once such an address table is used, the call is established in the following way:
- Gateway tries to send the number by first communicating with 1st Gatekeeper.
- If communication with 1st Gatekeeper is not established, then communicate with 2nd
Gatekeeper is tried.
- If communication with any Gatekeeper is not established in a certain period, then the
address row with destination Gateway is taken into account and the call is established
as per this row.
As seen from the table, the numbers are entered in different format for Gatekeeper and
Gateway. Although number of digits of the called number should be specified for Gateway, it
is not necessary to indicate the number of digits for Gatekeeper. The number of digits is
determined by Parameters options for Gatekeeper.
The address rows should be filled out by considering the number of dialled digits with
Destination specified as Gateway.
In both conditions, the address table and LCR table must be in match.
The following rows should be available on LCR table of system A:
System A
10
DS200 KNEE Programming Guide
Route Table:
Route 1
No Filter No External line ARS level
1 1 1678 0
There should not be any filtering option for Filter 1. Furthermore a PBX group including the
external lines 1678, 1679, 1680 and 1681 should be formed.
Capability Table
The values on this table should not be change without consulting the technical service.
Parameters
11
DS200 KNEE Programming Guide
- Gain adjustments: These settings can be done for input and output with ranges of 6 dB
and can be improved by fine tuning.
- Media transmit rate: This value determines the packet duration. When a small value is
entered, the necessity a bigger bandwidth arises. However, a big value can result with
loss of bigger packets in case of a problem. The ideal value is 4. For uses with Cisco, it
should be entered as 2. The entered value determines the packet duration in terms of 10
milliseconds.
- Call establish wait time: Determines the maximum duration for waiting for Gateways
answer for the calls established through Gateway.
- TCP close time: TCP is closed after the specified time when the conversation is over.
- TCP abort time: TCP is closed after the specified time in case of an error.
- TCP retransmit time: For the case when there is a risk of packet loss, the same packet is
sent after the specified time.
- ECO canceller: It should always be set as Yes.
- Monitor: When set as 1, DS200 Log Listener program can be used for monitoring
purposes.
- faststart: This value should be set as 1 in order to eliminate H245 and to establish
communication with H225 in a faster way. If the system which has connection to DS20
over VoIP does not support faststart, then the value of this parameter must be 0.
- maximum digits (gatekeeper): When the calls are established through Gatekeeper, VoIP
card send the call to the Gatekeeper after the specified number of digits are dialled.
- Gatekeeper ACF timer: Before the call starts, Gateway asks Gatekeeper about the IP
address of the number that is going to be routed (Admission Request-ARQ). If the answer
to this questions (Admission Confirmation-ACF) is not received within the specified time,
the calls is established though Gateway, instead of Gatekeeper.
Write to EEPROM
This option should be used to write all of the parameters in the volatile memory after the
programming finished (this option should never be activated when there are ongoing
conversations).
12
DS200 KNEE Programming Guide
(Please see programming manual for the details of the 800470 coded program.)
After the LAN connection of the LAN Adaptor is made by a standard network cable, the card
can be reached by KNEE program.
13
DS200 KNEE Programming Guide
Note: As in VoIP cards application, when shortcut of KNEE is used, LAN Adaptor card with
the desired IP address can be reached.
When right-clicked by the mouse on the LAN Adaptor seen on the main window, two options
appear:
14
DS200 KNEE Programming Guide
Settings
In addition to the values defined by the 800480 coded program, this window shows the
following information:
AdmPort: TCP/IP communication port number.
DS200 No: Used for monitoring purposes. It does not have any functionality in normal
operation.
Write to EEPROM
This option should be used to write all of the parameters in the volatile memory after the
programming finished (this option should never be activated when there are ongoing
connections).
15
DS200 KNEE Programming Guide
After this setting, ADMIN200 program searches for this IP on its LAN and once this IP is
found, the program works normally just like communicating via RS232.
16